Skip Content
You are currently on the new version of our website. Access the old version .

57 Results Found

  • Article
  • Open Access
3 Citations
5,529 Views
9 Pages

Impact of Radial Lands on the Reduction of Torque/Force Generation of a Heat-Treated Nickel-Titanium Rotary Instrument

  • Taro Nakatsukasa,
  • Arata Ebihara,
  • Moe Sandar Kyaw,
  • Satoshi Omori,
  • Hayate Unno,
  • Shunsuke Kimura,
  • Keiichiro Maki and
  • Takashi Okiji

3 March 2022

This study investigated the impact of a one-sided radial-landed cross-sectional design of a heat-treated nickel-titanium rotary instrument (JIZAI, MANI, Japan; JZ) on torque/force generation and canal-shaping ability, using an experimental non-landed...

  • Review
  • Open Access
84 Citations
10,020 Views
18 Pages

An Update on Nickel-Titanium Rotary Instruments in Endodontics: Mechanical Characteristics, Testing and Future Perspective—An Overview

  • Alessio Zanza,
  • Maurilio D’Angelo,
  • Rodolfo Reda,
  • Gianluca Gambarini,
  • Luca Testarelli and
  • Dario Di Nardo

Since the introduction of Nickel-Titanium alloy as the material of choice for the manufacturing of endodontic rotary instruments, the success rate of the root canal therapies has been significantly increased. This success mainly arises from the prope...

  • Review
  • Open Access
15 Citations
5,303 Views
16 Pages

30 March 2021

The aim of this review was to provide a detailed literature analysis of torque and force generation during nickel-titanium rotary root canal instrumentation. We followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guid...

  • Article
  • Open Access
562 Views
12 Pages

Impact of Downward Load and Rotational Kinematics on Root Canal Instrumentation with a Heat-Treated Nickel–Titanium Rotary Instrument

  • Risako Yamamoto,
  • Keiichiro Maki,
  • Shunsuke Kimura,
  • Satoshi Omori,
  • Keiko Hirano,
  • Arata Ebihara,
  • Yoshio Yahata and
  • Takashi Okiji

28 December 2025

This study analyzed how different downward loads and rotational kinematics influence NiTi rotary instrumentation outcomes. Heat-treated NiTi instruments were used to prepare extracted human single-rooted premolars with a moderate canal curvature. Ins...

  • Article
  • Open Access
16 Citations
3,557 Views
11 Pages

Mechanical and Metallurgical Evaluation of 3 Different Nickel-Titanium Rotary Instruments: An In Vitro and In Laboratory Study

  • Alessio Zanza,
  • Paola Russo,
  • Rodolfo Reda,
  • Paola Di Matteo,
  • Orlando Donfrancesco,
  • Pietro Ausiello and
  • Luca Testarelli

An in-depth evaluation of the mechanical and metallurgical properties of NiTi instruments is fundamental to assess their performance and to compare recently introduced instrument with widespread ones. According to this, since there are no data on thi...

  • Article
  • Open Access
3 Citations
1,280 Views
12 Pages

31 December 2024

The optimal amplitude of pecking motion during nickel–titanium rotary root canal instrumentation remains unclear. This study evaluated how different pecking amplitudes influence the force/torque generation, canal-centering ability, and cyclic f...

  • Article
  • Open Access
2 Citations
711 Views
11 Pages

Thermal Treatment Prevents Effects of Downward Loads on the Screw-In Force Generation and Canal-Centering Ability of Nickel–Titanium Rotary Instruments

  • Keiichiro Maki,
  • Arata Ebihara,
  • Yanshan Luo,
  • Yuka Kasuga,
  • Hayate Unno,
  • Satoshi Omori,
  • Shunsuke Kimura and
  • Takashi Okiji

31 July 2025

This study aimed to examine how downward load applied during instrumentation affects the stress generation and shaping properties in thermally treated and non-treated NiTi rotary instruments. ProTaper Universal (PTU; non-thermally treated) and ProTap...

  • Editorial
  • Open Access
2 Citations
3,081 Views
3 Pages

14 February 2022

During the last two decades, the field of the nickel–titanium (NiTi) rotary instruments has been thoroughly changed by the latest, exciting innovations in both manufacturing technologies and the knowledge of their mechanical performance [...]

  • Article
  • Open Access
7 Citations
2,344 Views
9 Pages

Effect of Rotational Modes on Torque/Force Generation and Canal Centering Ability during Rotary Root Canal Instrumentation with Differently Heat-Treated Nickel–Titanium Instruments

  • Satoshi Omori,
  • Arata Ebihara,
  • Keiko Hirano,
  • Yuka Kasuga,
  • Hayate Unno,
  • Taro Nakatsukasa,
  • Shunsuke Kimura,
  • Keiichiro Maki,
  • Takao Hanawa and
  • Takashi Okiji

2 October 2022

This study aimed to evaluate how various rotational modes influence the torque/force production and shaping ability of ProTaper Universal (PTU; non-heat-treated) and ProTaper Gold (PTG; heat-treated) nickel–titanium instruments. J-shaped resin...

  • Article
  • Open Access
218 Views
11 Pages

31 December 2025

Effective gutta-percha/sealer removal is essential for predictable nonsurgical endodontic retreatment, but the effects of key operational parameters on nickel–titanium rotary removal instruments remain insufficiently understood. This study aime...

  • Article
  • Open Access
4 Citations
4,168 Views
8 Pages

20 November 2020

Nickel-titanium (NiTi) endodontic rotary instruments are used extensively in root canal procedures by both general dentists and specialists. However, their vulnerability to fracture is the major reason for clinicians’ concern regarding their us...

  • Article
  • Open Access
6 Citations
3,075 Views
8 Pages

Shaping Ability and Debris Extrusion of New Rotary Nickel-Titanium Root Canal Instruments

  • Sebastian Bürklein,
  • David Donnermeyer,
  • Tim Julian Hentschel and
  • Edgar Schäfer

24 February 2021

The aim was to evaluate the canal straightening and the amount of apically extruded debris associated with five rotary nickel-titanium when preparing curved root canals. A total of 100 root canals in extracted human teeth (angles of curvatures 20°–30...

  • Systematic Review
  • Open Access
2 Citations
1,606 Views
49 Pages

Effect of Endodontic Irrigants on the Cyclic Fatigue Resistance of Nickel–Titanium Rotary Instruments: A Systematic Review

  • Bartłomiej Karaś,
  • Agnieszka Kotela,
  • Marzena Laszczyńska,
  • Zuzanna Majchrzak,
  • Mateusz Trafalski,
  • Jacek Matys and
  • Maciej Dobrzyński

29 August 2025

Instrument fracture during endodontic treatment significantly compromises treatment outcomes, with sodium hypochlorite (NaOCl) and other irrigants potentially affecting the cyclic fatigue resistance of nickel–titanium (NiTi) rotary files. This...

  • Communication
  • Open Access
11 Citations
2,565 Views
14 Pages

6 February 2023

Background: To evaluate the cyclic fatigue resistance of rotary endodontic nickel-titanium instruments using both experimental and finite element methods. Methodology: Four different proprietary rotary endodontic instruments (PTG, PTU, VB, and TRN) w...

  • Article
  • Open Access
7 Citations
2,849 Views
15 Pages

24 November 2022

This study aimed to evaluate and compare the effects of ambient temperature and post-manufacture heat-treatment on the mechanical behavior of nickel-titanium (NiTi) wires. Four types of commercial NiTi variants (Stock NiTi, heat treated “Blue&r...

  • Article
  • Open Access
286 Views
10 Pages

Effect of Clockwise Reciprocation Motion of Optimum Torque Reverse Kinematic on the Cyclic Fatigue Resistance of Nickel–Titanium Rotary Instruments with Different Metallurgical Properties

  • Jorge N. R. Martins,
  • Emmanuel J. N. L. Silva,
  • Duarte Marques,
  • João Caramês,
  • Francisco M. Braz Fernandes and
  • Marco A. Versiani

18 January 2026

This study evaluated the effect of clockwise reciprocation motion used in the original Optimum Torque Reverse kinematics, compared with clockwise continuous rotation, on the cyclic fatigue strength of nickel–titanium rotary instruments (NiTi) w...

  • Article
  • Open Access
2,357 Views
13 Pages

Wear Analysis of Four Different Single-File Reciprocating Instruments before and after Four Uses in Simulated Root Canals

  • Alessio Zanza,
  • Rodolfo Reda,
  • Giuseppe Familiari,
  • Stefania Annarita Nottola,
  • Dario Di Nardo,
  • Luca Testarelli and
  • Orlando Donfrancesco

20 June 2022

The aim of this study is to assess the surface alterations of four reciprocating instruments before and after the shaping of four resin-simulated root canals. The following four different reciprocating instruments are selected: 10 Reciproc Blue (RB25...

  • Review
  • Open Access
36 Citations
5,297 Views
16 Pages

Metallurgical Tests in Endodontics: A Narrative Review

  • Alessio Zanza,
  • Marco Seracchiani,
  • Rodolfo Reda,
  • Gabriele Miccoli,
  • Luca Testarelli and
  • Dario Di Nardo

Since there are no reviews of the literature on this theme, the aim of this narrative review is to summarize the metallurgical tests used in endodontics, pointing out their functional use and their pros and cons and giving readers a user-friendly gui...

  • Article
  • Open Access
2 Citations
1,345 Views
18 Pages

Multimodal Evaluation of Three NiTi Rotary Systems: Clinical Simulation, Mechanical Testing, and Finite Element Analysis

  • Jesus A. Aparicio,
  • Pedro M. Mendez S,
  • Giulia Malvicini,
  • Simone Grandini,
  • Carlo Gaeta,
  • Ana Paula García Guerrero,
  • Kristel Lidice Miranda Robles,
  • José Aranguren and
  • Alejandro R. Pérez

15 August 2025

Objectives: This study aimed to compare the clinical durability, mechanical performance, and stress behavior of three NiTi rotary systems—BlueShaper (Blue), BlueShaper Pro (Dual Wire), and BlueShaper Gold (fully gold-treated NiTi)—through...

  • Editorial
  • Open Access
1,408 Views
4 Pages

Are the Current Research Methods Reliable for Evaluating the Mechanical Performance of NiTi Endodontic Rotary Instruments?

  • Franco Maria Di Russo,
  • Annamaria Gisario,
  • Stefano Natali,
  • Valentina Bellanova,
  • Chiara Leone and
  • Luca Testarelli

9 November 2022

Technological innovation and the modernization of manufacturing procedures have thoroughly redefined the field of nickel–titanium (NiTi) rotary and reciprocating endodontic instruments [...]

  • Article
  • Open Access
21 Citations
3,405 Views
11 Pages

Angle of Insertion and Torsional Resistance of Nickel–Titanium Rotary Instruments

  • Dario Di Nardo,
  • Alessio Zanza,
  • Marco Seracchiani,
  • Orlando Donfrancesco,
  • Gianluca Gambarini and
  • Luca Testarelli

4 July 2021

Previously published studies have investigated the influence of instrument access on cyclic fatigue resistance. However, no studies have evaluated the relationship between angulated access and torsional resistance. The aim of this study was to invest...

  • Review
  • Open Access
22 Citations
10,433 Views
13 Pages

Endodontic Rotary Files, What Should an Endodontist Know?

  • Ana-Belén Dablanca-Blanco,
  • Pablo Castelo-Baz,
  • Ramón Miguéns-Vila,
  • Pablo Álvarez-Novoa and
  • Benjamín Martín-Biedma

Clinicians should be aware of all the characteristics and capacities of the instruments that are possible to use when conducting a root canal treatment. The wide variety of nickel–titanium (Ni-Ti) rotary systems on the market and the lack of st...

  • Article
  • Open Access
1 Citations
3,721 Views
10 Pages

Multimethod Assessment of the Cyclic Fatigue Strength of ProGlider, Edge Glide Path and R-Pilot Endodontic Instruments

  • Jorge N. R. Martins,
  • Duarte Marques,
  • Isabel Vasconcelos,
  • Sofia Arantes-Oliveira,
  • João Caramês and
  • Francisco Manuel Braz Fernandes

17 February 2022

Background: The aim of this study was to comprehensively evaluate the cyclic fatigue strength of ProGlider, Edge Glide Path, and R-Pilot instruments. Methods: Sixty-three instruments were submitted to a multimethod evaluation. Their design was analyz...

  • Article
  • Open Access
2 Citations
1,995 Views
11 Pages

Comprehensive Assessment of Cyclic Fatigue Strength in Five Multiple-File Nickel–Titanium Endodontic Systems

  • Jorge N. R. Martins,
  • Emmanuel J. N. L. Silva,
  • Duarte Marques,
  • Francisco M. Braz Fernandes and
  • Marco A. Versiani

15 May 2024

The resistance of nickel–titanium endodontic instruments against cyclic fatigue failure remains a significant concern in clinical settings. This study aimed to assess the cyclic fatigue strength of five nickel–titanium rotary systems, whi...

  • Article
  • Open Access
28 Citations
6,635 Views
14 Pages

Design, Metallurgical Features, and Mechanical Behaviour of NiTi Endodontic Instruments from Five Different Heat-Treated Rotary Systems

  • Jorge N. R. Martins,
  • Emmanuel J. N. L. Silva,
  • Duarte Marques,
  • Mário Rito Pereira,
  • Victor T. L. Vieira,
  • Sofia Arantes-Oliveira,
  • Rui F. Martins,
  • Francisco Braz Fernandes and
  • Marco Versiani

28 January 2022

The current study aimed to compare the F1 endodontic instruments from five different heat-treated rotary systems regarding their design, metallurgical properties, and mechanical performance. Five F1 root canal shaping instruments (ProTaper Gold [PTG]...

  • Systematic Review
  • Open Access
10 Citations
7,354 Views
19 Pages

Cyclic Fatigue Resistance of Rotary versus Reciprocating Endodontic Files: A Systematic Review and Meta-Analysis

  • Ana De Pedro-Muñoz,
  • Cristina Rico-Romano,
  • Patricia Sánchez-Llobet,
  • José María Montiel-Company and
  • Jesús Mena-Álvarez

2 February 2024

(1) Background: The failure of nickel–titanium (NiTi) rotary files is a complication related to endodontic instruments. The aim of this study was to compare the resistance to cyclic fatigue between rotary and reciprocating file systems. (2) Met...

  • Article
  • Open Access
54 Citations
5,280 Views
8 Pages

Role of the Flat-Designed Surface in Improving the Cyclic Fatigue Resistance of Endodontic NiTi Rotary Instruments

  • Gianluca Gambarini,
  • Gabriele Miccoli,
  • Marco Seracchiani,
  • Tatyana Khrenova,
  • Orlando Donfrancesco,
  • Maurilio D’Angelo,
  • Massimo Galli,
  • Dario Di Nardo and
  • Luca Testarelli

8 August 2019

The aim of this study was to investigate the role of the flat-designed surface in improving the resistance to cyclic fatigue by comparing heat-treated F-One (Fanta Dental, Shanghai, China) nickel–titanium (NiTi) rotary instruments and similar p...

  • Article
  • Open Access
9 Citations
2,957 Views
12 Pages

Mechanical Properties and Root Canal Shaping Ability of a Nickel–Titanium Rotary System for Minimally Invasive Endodontic Treatment: A Comparative In Vitro Study

  • Hayate Unno,
  • Arata Ebihara,
  • Keiko Hirano,
  • Yuka Kasuga,
  • Satoshi Omori,
  • Taro Nakatsukasa,
  • Shunsuke Kimura,
  • Keiichiro Maki and
  • Takashi Okiji

9 November 2022

Selection of an appropriate nickel–titanium (NiTi) rotary system is important for minimally invasive endodontic treatment, which aims to preserve as much root canal dentin as possible. This study aimed to evaluate selected mechanical properties...

  • Article
  • Open Access
17 Citations
5,670 Views
14 Pages

The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device

  • Vicente Faus-Llácer,
  • Nirmine Hamoud Kharrat,
  • Celia Ruiz-Sánchez,
  • Ignacio Faus-Matoses,
  • Álvaro Zubizarreta-Macho and
  • Vicente Faus-Matoses

18 January 2021

The aim of this study was to analyze the effect of the taper and apical diameter of nickel–titanium (NiTi) endodontic rotary files on the dynamic cyclic fatigue resistance. A total of 50 unused conventional NiTi wire alloy endodontic rotary ins...

  • Article
  • Open Access
11 Citations
2,945 Views
8 Pages

In Vitro Analysis of the Fatigue Resistance of Four Single File Canal Preparation Instruments

  • Mohammad I. Al-Obaida,
  • Abdulmohsen A. Alzuwayer,
  • Saqer S. Alanazi and
  • Abdulrahman A. Balhaddad

17 January 2022

Instrument separation during root canal therapy is inevitable in endodontics with several unfavorable clinical consequences. Therefore, examining the cyclic flexural fatigue resistance of commonly used rotary endodontic files is crucial. This study a...

  • Article
  • Open Access
11 Citations
4,674 Views
7 Pages

Effective Establishment of Glide-Path to Reduce Torsional Stress during Nickel-Titanium Rotary Instrumentation

  • Ibrahim H. Abu-Tahun,
  • Sang Won Kwak,
  • Jung-Hong Ha,
  • Asgeir Sigurdsson,
  • Mehmet Baybora Kayahan and
  • Hyeon-Cheol Kim

5 February 2019

This study compared the torque generation during canal shaping with a nickel-titanium endodontic instrument according to the extent of glide-path establishment. Seventy-five simulated S-shaped canal blocks were divided into five groups (n = 15) accor...

  • Article
  • Open Access
4 Citations
5,285 Views
9 Pages

Assessment of Different Root Canal Preparation Techniques with Rotary Nickel-Titanium Instruments by Novice Students

  • Andreas Bartols,
  • David W. Christofzik,
  • Matthias Krummel,
  • Christian Friedrichs,
  • Tim Pousset,
  • Birte Größner-Schreiber and
  • Christof E. Dörfer

4 September 2018

This study investigated which preparation strategy for root canals leads to the best technical preparation quality, and moreover, which is perceived to be performed best by novice students. Sixty-four students were recruited to prepare one simulated...

  • Article
  • Open Access
14 Citations
2,601 Views
6 Pages

A New Device to Test the Bending Resistance of Mechanical Endodontic Instruments

  • Gabriele Miccoli,
  • Andrea Cicconetti,
  • Gianluca Gambarini,
  • Andrea Del Giudice,
  • Federico Ripanti,
  • Dario Di Nardo,
  • Luca Testarelli and
  • Marco Seracchiani

16 October 2020

The aims of the present study were to propose a new machine for testing the bending behavior of an instrument at multiple specific points along the cutting surface and to compare the influence of proprietary heat treatment on the bending ability of E...

  • Article
  • Open Access
10 Citations
4,634 Views
13 Pages

28 September 2021

Current improvements in nickel-titanium (Ni-Ti) rotary file systems have created a paradigm shift in the root canal therapy of primary teeth. Therefore, it is necessary to perform a comprehensive evaluation regarding the efficiencies of newly manufac...

  • Article
  • Open Access
8 Citations
2,573 Views
10 Pages

Torsional Resistance of Heat-Treated Nickel-Titanium Instruments under Different Temperature Conditions

  • Hyo Jin Jo,
  • Sang Won Kwak,
  • Hyeon-Cheol Kim,
  • Sung Kyo Kim and
  • Jung-Hong Ha

14 September 2021

This study compared the torsional resistance of heat-treated nickel-titanium (NiTi) instruments under different temperature conditions. Four thermomechanically treated single-use NiTi rotary instruments were selected for this study: OneShape (OS), On...

  • Article
  • Open Access
16 Citations
8,388 Views
11 Pages

Cleaning Effectiveness of Three NiTi Rotary Instruments: A Focus on Biomaterial Properties

  • Claudio Poggio,
  • Alberto Dagna,
  • Marco Chiesa,
  • Riccardo Beltrami and
  • Stefano Bianchi

16 February 2015

Nickel-titanium (NiTi) instruments are commonly used for shaping the root canal system in endodontic practice. They are more flexible and have better cutting efficiency than conventional stainless steel files. The superelasticity of NiTi rotary files...

  • Article
  • Open Access
9 Citations
2,430 Views
9 Pages

4 December 2020

Objectives: This study aimed to compare the ex vivo performance of two rotary nickel–titanium (NiTi) systems with similar designs but manufactured from martensitic and austenitic alloys, the One Curve (OC) and One Shape (OS) rotary endodontic f...

  • Review
  • Open Access
5 Citations
6,585 Views
24 Pages

Glide Path in Endodontics: A Literature Review of Current Knowledge

  • Vlad Mircea Lup,
  • Giulia Malvicini,
  • Carlo Gaeta,
  • Simone Grandini and
  • Gabriela Ciavoi

14 August 2024

The introduction of nickel–titanium rotary instruments revolutionized shaping procedures as they were able to produce a well-tapered preparation while reducing operator fatigue. The major drawback of rotary instruments was the high risk of frac...

  • Review
  • Open Access
27 Citations
5,669 Views
10 Pages

Torque Generation of the Endodontic Instruments: A Narrative Review

  • Sang Won Kwak,
  • Ya Shen,
  • He Liu,
  • Hyeon-Cheol Kim and
  • Markus Haapasalo

17 January 2022

As the use of nickel-titanium (NiTi) file systems for root canal therapy has become popular; hence, knowledge and understanding of the characteristics of NiTi files is essential for dentists. Unintended sudden fracture can occur during root canal sha...

  • Article
  • Open Access
7 Citations
1,098 Views
12 Pages

Comparison of Four Ni-Ti Rotary Systems: Dental Students’ Perceptions in a Multi-Center Simulated Study

  • Francesco Puleio,
  • Vincenzo Tosco,
  • Riccardo Monterubbianesi,
  • Rosario Pirri,
  • Angela Alibrandi,
  • Daria Pulvirenti and
  • Michele Simeone

24 February 2025

Background/Objectives: Nickel–titanium (Ni-Ti) rotary instruments have significantly enhanced the efficiency and safety of root canal shaping. However, the variety of Ni-Ti systems, characterized by differences in alloy composition, taper desig...

  • Article
  • Open Access
19 Citations
3,572 Views
9 Pages

Evaluation of Pressure Distribution against Root Canal Walls of NiTi Rotary Instruments by Finite Element Analysis

  • Giorgia Carpegna,
  • Mario Alovisi,
  • Davide Salvatore Paolino,
  • Andrea Marchetti,
  • Umberto Gibello,
  • Nicola Scotti,
  • Damiano Pasqualini,
  • Alessandro Scattina,
  • Giorgio Chiandussi and
  • Elio Berutti

24 April 2020

The aim of this study was to evaluate the contact pressure distribution of two different nickel-titanium (NiTi) endodontic rotary instruments against the root canal walls and to virtually predict their centering ability during shaping with finite ele...

  • Article
  • Open Access
4 Citations
2,307 Views
16 Pages

A Comparative Analysis of ProTaper Ultimate and Five Multifile Systems: Design, Metallurgy, and Mechanical Performance

  • Jorge N. R. Martins,
  • Emmanuel João Nogueira Leal Silva,
  • Victor Talarico Leal Vieira,
  • Rui Pereira da Costa,
  • Abayomi O. Baruwa,
  • Francisco Manuel Braz Fernandes and
  • Marco Aurélio Versiani

13 March 2025

The present research compared the design, metallurgical properties, and mechanical characteristics of the ProTaper Ultimate instruments with five multifile systems. A total of 469 new nickel–titanium rotary finishing instruments, all 25 mm in l...

  • Article
  • Open Access
454 Views
13 Pages

Effects of Three Types of Movements of Nickel–Titanium Instruments on Root Canal Preparation: Analysis by Using Cone-Beam Computed Tomography

  • Kinga Kaczor-Wiankowska,
  • Maciej Czechowski,
  • Philipp Arndt,
  • Aleksandra Joanna Wiankowska,
  • Weronika Kwiecień and
  • Katarzyna Lewusz-Butkiewicz

1 December 2025

The development of endodontics leads to increasingly innovative techniques, which improve mechanical root canal preparation. Endostar E3 Azure (Poldent Co., Warsaw, Poland) is a nickel–titanium file, which can be used in rotary, reciprocal, and...

  • Article
  • Open Access
4 Citations
3,146 Views
10 Pages

19 February 2023

The present study aims to measure the number of cycles leading to fracture (NCF) of instruments in static and dynamic cyclic fatigue situations under body temperature in stainless steel double-curved canals. The framework was constructed to establish...

  • Article
  • Open Access
19 Citations
2,717 Views
8 Pages

Evaluation of the Cyclic Fatigue of Two Single Files at Body and Room Temperature with Different Radii of Curvature

  • Giusy Rita Maria La Rosa,
  • Valeria Shumakova,
  • Gaetano Isola,
  • Francesco Indelicato,
  • Calogero Bugea and
  • Eugenio Pedullà

27 April 2021

Background: To compare the influence of different temperatures and curvature radii on the cyclic fatigue resistance of F6 SkyTaper (F6ST) and One Curve (OC) single file nickel-titanium rotary instruments. Methods: A total of 120 instruments of F6ST a...

  • Article
  • Open Access
8 Citations
2,582 Views
9 Pages

Effect of Different Downward Loads on Canal Centering Ability, Vertical Force, and Torque Generation during Nickel–Titanium Rotary Instrumentation

  • Keiichiro Maki,
  • Arata Ebihara,
  • Hayate Unno,
  • Satoshi Omori,
  • Taro Nakatsukasa,
  • Shunsuke Kimura and
  • Takashi Okiji

7 April 2022

This study aimed to examine how downward loads influence the torque/force and shaping outcome of ProTaper NEXT (PTN) rotary instrumentation. PTN X1, X2, and X3 were used to prepare J-shaped resin canals employing a load-controlled automated instrumen...

  • Article
  • Open Access
16 Citations
3,205 Views
13 Pages

A Multimethod Assessment of a New Customized Heat-Treated Nickel–Titanium Rotary File System

  • Emmanuel J. N. L. Silva,
  • Jorge N. R. Martins,
  • Natasha C. Ajuz,
  • Henrique S. Antunes,
  • Victor T. L. Vieira,
  • Francisco M. Braz Fernandes,
  • Felipe G. Belladonna and
  • Marco A. Versiani

31 July 2022

This study aimed to compare three endodontic rotary systems. The new Genius Proflex (25/0.04), Vortex Blue (25/0.04), and TruNatomy (26/0.04v) instruments (n = 41 per group) were analyzed regarding design, metallurgy, and mechanical performance, whil...

  • Article
  • Open Access
8 Citations
3,981 Views
16 Pages

A Novel Endodontic Approach in Removing Smear Layer Using Nano and Submicron Diamonds with Intracanal Oscillation Irrigation

  • Ching-Shuan Huang,
  • Chih-Hsun Hsiao,
  • Yu-Chia Chang,
  • Chih-Hsiang Chang,
  • Jen-Chang Yang,
  • James L. Gutmann,
  • Huan-Cheng Chang,
  • Haw-Ming Huang and
  • Sung-Chih Hsieh

15 May 2023

Sodium hypochlorite (NaOCl) and ethylenediaminetetraacetic acid (EDTA) are commonly recommended for effectively removing organic and inorganic components in the smear layer. This layer is found on root canal walls after root canal instrumentation. Ho...

  • Article
  • Open Access
4 Citations
6,046 Views
11 Pages

Influence of Coronal Flaring on the Shaping Ability of Two Heat-Treated Nickel-Titanium Endodontic Files: A Micro-Computed Tomographic Study

  • Nadine Hawi,
  • Eugenio Pedullà,
  • Giusy Rita Maria La Rosa,
  • Gianluca Conte,
  • Walid Nehme and
  • Prasanna Neelakantan

2 January 2023

Nickel-titanium (NiTi) usage is associated in endodontics with some complications including canal transportation. Centering ability of a NiTi file is the ability to stay centered in the root canal system during instrumentation. Any undesirable deviat...

  • Article
  • Open Access
27 Citations
2,419 Views
8 Pages

Role of the Crystallographic Phase of NiTi Rotary Instruments in Determining Their Torsional Resistance during Different Bending Conditions

  • Alessio Zanza,
  • Marco Seracchiani,
  • Rodolfo Reda,
  • Dario Di Nardo,
  • Gianluca Gambarini and
  • Luca Testarelli

23 October 2021

The aim of this study was to assess the role of the crystallographic phase of Nickel-titanium (NiTi) rotary instruments in determining their torsional resistance during different bending conditions, such as different degrees and angles of curvature....

of 2