Next Issue
Volume 12, August
Previous Issue
Volume 12, June
 
 

Tomography, Volume 12, Issue 7 (July 2026) – 17 articles

Cover Story (view full-size image): Space exploration exposes astronauts to a unique radiation environment dominated by galactic cosmic rays and solar particle events, raising concerns about long-term cancer risk during extended missions beyond low-Earth orbit. This review examines current evidence on space radiation carcinogenesis, available risk-prediction models, and the major uncertainties related to dose estimation, radiation quality, and individual susceptibility. Particular attention is given to emerging imaging approaches and their potential role in monitoring radiation-induced biological effects and supporting personalized risk assessment. A better understanding of these mechanisms will be essential for protecting astronauts’ health during future missions to the Moon, Mars, and beyond. View this paper
  • Issues are regarded as officially published after their release is announced to the table of contents alert mailing list.
  • You may sign up for e-mail alerts to receive table of contents of newly released issues.
  • PDF is the official format for papers published in both, html and pdf forms. To view the papers in pdf format, click on the "PDF Full-text" link, and use the free Adobe Reader to open them.
Order results
Result details
Section
Select all
Export citation of selected articles as:
14 pages, 2762 KB  
Article
Ocular Radiation Exposure and Shielding Practices During Complex Fluoroscopic Guided Interventions: An Exploratory Multicenter Observational Study
by Mathias Grau, Osama Eldergash, Sandeep Sunder Amin, Martin H. Maurer, Matteo Haupt, Vivek Chopda, Björn Poppe, Bernhard Schmuck, Arne Schwindt, Andreas Cöster, Torsten Schütz, Anika Wißmann, Rohit Philip Thomas and Christian Mathys
Tomography 2026, 12(7), 107; https://doi.org/10.3390/tomography12070107 - 20 Jul 2026
Viewed by 278
Abstract
Background/Objectives: Lead acrylic shields (LASs) enhance radiation protection, with variation of their usage among different specialties. This prospective multicentric observational study aimed to explore patterns of ocular radiation exposure and LAS usage among interventionalists from different disciplines and to assess behavioral dose changes [...] Read more.
Background/Objectives: Lead acrylic shields (LASs) enhance radiation protection, with variation of their usage among different specialties. This prospective multicentric observational study aimed to explore patterns of ocular radiation exposure and LAS usage among interventionalists from different disciplines and to assess behavioral dose changes in a longitudinally monitored subgroup. Methods: From July 2019 to July 2020, ocular doses (protected and unprotected) were measured in 15 interventionalists from four specialties (radiology, neuroradiology, cardiology and vascular surgery) across 2286 procedures using thermoluminescent dosimeters. Procedure type, operator position, total body dose, fluoroscopy time, dose area product, LAS usage and dose exceedances were documented. Ocular doses of five interventionalists, who participated in our previous study, allowed a longitudinal comparison of radiation doses and protective behavior. Results: Cumulative annual unprotected ocular doses ranged from 0 to 59 mSv, with five participants exceeding the annual limit of 20 mSv, whereas protected doses (0 to 18 mSv) remained within the limits. Procedural LAS usage was seen in 89% of radiologists and 82% of vascular surgeons. Participants with 100% LAS usage recorded minimal measurable ocular doses, whereas lower LAS compliance resulted in higher ocular doses. Longitudinal subgroup data analyses showed a decrease in ocular dose per procedure in all five participants, suggesting a potential learning effect, without statistical significance. Conclusions: Unprotected ocular doses exceeded the annual occupational eye lens dose limit in several participants, whereas protected doses remained within recommended limits in all participants. No specialty demonstrated universally lower ocular doses, while consistent LAS use proved highly effective in reducing the dose in all groups. Longitudinal findings suggest that structured dose monitoring and repeated training may support behavioral improvements in radiation protection over time. Full article
(This article belongs to the Special Issue Imaging in Vascular Interventional Radiology)
Show Figures

Figure 1

18 pages, 8391 KB  
Review
Space Radiation and Cancer Risk in Astronauts: Models, Evidence, Uncertainties, and Emerging Imaging Perspectives
by Chiara Zanon, Michele Basilicata, Agostino Chiaravalloti, Nicola Giannotti, Amalia Lupi, Filippo Crimì and Emilio Quaia
Tomography 2026, 12(7), 106; https://doi.org/10.3390/tomography12070106 - 17 Jul 2026
Viewed by 398
Abstract
Cancer risk estimation remains one of the main unresolved challenges in human spaceflight beyond low Earth orbit, where astronauts are exposed to galactic cosmic rays, solar particle events, and high-linear energy transfer (high-LET) secondary radiation. This narrative review summarizes the principal quantitative models [...] Read more.
Cancer risk estimation remains one of the main unresolved challenges in human spaceflight beyond low Earth orbit, where astronauts are exposed to galactic cosmic rays, solar particle events, and high-linear energy transfer (high-LET) secondary radiation. This narrative review summarizes the principal quantitative models used to estimate radiation-induced cancer risk in astronauts, including particle fluence-based cross-sections, mixture models, risk of exposure-induced death (REID)-based operational frameworks, uncertainty distribution approaches, and ensemble models. Early studies estimated 1-year excess cancer mortality at solar minimum as 1.3% in women and 1.1% in men under 10 g/cm2 aluminum shielding, whereas later models projected non-leukemia lifetime cancer incidence after 1 Sv dose equivalent/effective dose between 2.20% and 2.98%, depending on sex and age. Earlier REID-based models suggested that the historical 3% REID threshold could be exceeded after approximately 18 months in women and 24 months in men under unfavorable solar conditions, whereas the current NASA radiation standard uses a universal career-effective dose limit of 600 mSv, applied regardless of sex or age. More recent revisions of the NASA Space Cancer Risk model and non-targeted effect scenarios suggest that exploration mission risks may be higher than previously estimated, while uncertainty remains substantial, especially for high-LET radiobiology, mixed-field exposure, and the transfer of terrestrial epidemiological data to the spaceflight setting. Future progress may also involve exploring quantitative imaging biomarkers and tomographic assessments as complementary tools for longitudinal monitoring and early detection of radiation-related tissue changes, although these approaches are not yet validated as components of operational astronaut cancer risk models. Full article
(This article belongs to the Section Cancer Imaging)
Show Figures

Figure 1

21 pages, 11076 KB  
Article
Can AI Detect What Is Not Injected? Evaluation of Lesion Detection in Virtual Contrast-Enhanced Breast MRI Using a Large-Scale AI Model Trained on GBCA-Enhanced Data
by Shirin Heidarikahkesh, Hannes Schreiter, Aju George, Tri-Thien Nguyen, Dominika Skwierawska, Luise Brock, Dominique Hadler, Michael Uder, Frederik B. Laun, Chris Ehring, Johanna Graber, Lorenz Döppmann, Ihor Horishnyi, Lorenz A. Kapsner, Sabine Ohlmeyer, Andrzej Liebert and Sebastian Bickelhaupt
Tomography 2026, 12(7), 105; https://doi.org/10.3390/tomography12070105 - 16 Jul 2026
Viewed by 419
Abstract
Background/Objectives: Artificial intelligence (AI) can support lesion detection in gadolinium-based contrast agent-enhanced (GBCA-enhanced) breast MRI. However, its effectiveness on virtual contrast-enhanced (vCE) images remains unclear. This feasibility study evaluated the publicly available MAMA-MIA nnU-Net model trained on GBCA-enhanced data using an independent cohort [...] Read more.
Background/Objectives: Artificial intelligence (AI) can support lesion detection in gadolinium-based contrast agent-enhanced (GBCA-enhanced) breast MRI. However, its effectiveness on virtual contrast-enhanced (vCE) images remains unclear. This feasibility study evaluated the publicly available MAMA-MIA nnU-Net model trained on GBCA-enhanced data using an independent cohort of both GBCA-enhanced and vCE breast MRI. Methods: This IRB-approved retrospective study included the publicly available nnU-Net model trained on n = 1506 MAMA-MIA breast MRI scans and a cohort of n = 2126 in-house 3T breast MRI scans. A generative adversarial network (Pix2Pix-GAN) was developed on n = 1870 of the in-house scans and used to generate vCE data on the remaining independent n = 256 in-house cases. The MAMA-MIA nnU-net was applied to both GBCA-enhanced (GBCA) and corresponding vCE images. Ground-truth segmentations of malignant lesions served to calculate the Dice score, Hausdorff distance, and lesion dimension differences. Results: The final test set comprised n = 250 cases (n = 69 malignant, n = 181 benign). Lesion detection rates were 91% (n = 63/n = 69; 95% confidence interval (CI): 82.3–96.0%) for GBCA and 84% (n = 58/n = 69; 95% CI: 73.7–90.9%) for vCE. Two lesions missed in GBCA were identified by vCE. The Hausdorff distances were similar (GBCA: 6.4 (IQR: 3.2–9.3; 95% CI: 5.2–7.8) mm; vCE: 6.7 (IQR: 3.9–9.7; 95% CI: 5.3–8.0) mm, p = 0.564). The Dice scores showed minor differences (GBCA: 0.829 (IQR: 0.723–0.900; 95% CI: 0.786–0.865) vs. vCE: 0.826 (IQR: 0.720–0.857; 95% CI: 0.770–0.836); p < 0.001). vCE images had slightly higher non-target tissue segmentation (median 6072 mm3 vs. 5754 mm3). Conclusions: A GBCA-trained algorithm demonstrated some cross-domain transferability to vCE images, albeit with a reduced case-level sensitivity of 84% (95% CI: 73.7–90.9%) vs. 91% (95% CI: 82.3–96.0%). Based on these preliminary results, further research, including larger cohorts and more diverse datasets, is warranted. Full article
Show Figures

Figure 1

22 pages, 6161 KB  
Article
Clinical Robustness of FDG-PET/CT Quantitative Metrics Post-Harmonization in a Multicenter, Cross-Scanner Setting
by Ayako Hino, Yoshinobu Ishiwata, Akira Kakiuchi, Tomohiro Numata, Hiroyuki Kamide, Hiroaki Kurihara, Zenjiro Sekikawa and Daisuke Utsunomiya
Tomography 2026, 12(7), 104; https://doi.org/10.3390/tomography12070104 - 13 Jul 2026
Viewed by 305
Abstract
Background/Objectives: Differences among scanners and reconstruction methods may limit the comparability of quantitative metrics derived from fluorodeoxyglucose positron emission tomography (FDG PET)/computed tomography (CT). Although harmonization reduces inter-scanner variability in standardized uptake values (SUVs), its impact on the preservation of lesion-level ranking [...] Read more.
Background/Objectives: Differences among scanners and reconstruction methods may limit the comparability of quantitative metrics derived from fluorodeoxyglucose positron emission tomography (FDG PET)/computed tomography (CT). Although harmonization reduces inter-scanner variability in standardized uptake values (SUVs), its impact on the preservation of lesion-level ranking in real-world clinical datasets remains unclear. Here, we evaluated the robustness of PET quantitative metrics, particularly focusing on rank preservation after harmonization. Methods: Phantom and clinical data retrospectively acquired from three institutions using four PET/CT scanner types were analyzed. Harmonization parameters were derived from National Electrical Manufacturers Association IEC Body Phantom data, using the oldest scanner as the reference, and were directly applied to the clinical datasets. Clinical evaluation included head and neck malignant melanoma (HNMM; high FDG avidity) and adenoid cystic carcinoma (ACC; low FDG avidity). Rank preservation between pre- and post-harmonization values was assessed using Spearman’s rank correlation coefficient (ρ). Results: Phantom-based harmonization reduced inter-scanner differences and enabled consistent evaluation in clinical datasets (HNMM: 34 patients, 93 lesions; ACC: 18 patients, 38 lesions). SUVpeak demonstrated the highest rank preservation across tumor types and lesion sizes (ρ = 0.94–1.00). Metabolic tumor volume (MTV) showed a high rank correlation in HNMM with an absolute threshold (MTV2.5; ρ = 0.99), but robustness varied depending on threshold definition, tumor type, and lesion size. Tumor-to-liver ratios showed moderate rank preservation. Conclusions: Our results suggested that SUVpeak is the most robust preservation of lesion ranking across tumor types after harmonization, suggesting its suitability as a reliable imaging biomarker in multicenter studies. Meanwhile, careful standardization is needed when using MTV-based metrics for prognostic evaluation. Full article
(This article belongs to the Special Issue Progress in the Use of Advanced Imaging for Radiation Oncology)
Show Figures

Figure 1

15 pages, 6278 KB  
Article
Radiographic Analysis of Lower Limb Alignment in Patients with Knee Osteoarthritis
by Ozden Bedre Duygu, Figen Govsa, Anil Murat Ozturk and Mehmet Alp Ozmen
Tomography 2026, 12(7), 103; https://doi.org/10.3390/tomography12070103 - 7 Jul 2026
Viewed by 327
Abstract
Background and Objectives: Knee osteoarthritis (OA) is a prevalent musculoskeletal disorder. This study aims to assess the hip-knee-ankle anatomical alignment in patients with OA at different stages. Materials and Methods: Radiological images of 200 OA patients were analyzed to measure parameters such as [...] Read more.
Background and Objectives: Knee osteoarthritis (OA) is a prevalent musculoskeletal disorder. This study aims to assess the hip-knee-ankle anatomical alignment in patients with OA at different stages. Materials and Methods: Radiological images of 200 OA patients were analyzed to measure parameters such as femoral and tibial lengths (both anatomical and mechanical), abductor length, hip center length, femoral offset, collum femoris length, and shaft angle using ImageJ software (version 1.53k; National Institutes of Health, Bethesda, MD, USA). Results: The female-to-male ratio was 2.17:1. Male participants exhibited greater values for femoral and tibial lengths, abductor length, hip center length, femoral offset, collum femoris length, and collum femoris shaft angle, whereas females showed higher Q angle, hip–knee–ankle angle, mechanical lateral distal femoral angle, mechanical medial proximal tibial angle, and femoral angle measurements. Significant differences in both linear and angular parameters were observed among age groups. Q angle, hip–knee–ankle angle, femoral mechanical axis shaft angle, plateau angle, and ankle tilt angle values were significantly higher in individuals aged 62–75 years. According to Kellgren–Lawrence staging, significant increases were observed in Q angle, hip–knee–ankle angle, femoral mechanical axis shaft angle, plateau angle, and ankle tilt angle in advanced-stage disease (Stage 4) (p < 0.05). Although mechanical lateral distal femoral angle, femoral Q angle, tibial Q angle, condylar plateau angle, and tibiotalar angle showed numerical differences across disease stages, these findings did not reach statistical significance. Conclusions: Comprehensive assessment of lower-extremity alignment may provide complementary information regarding biomechanical changes associated with knee osteoarthritis progression and could support individualized clinical follow-up and treatment planning. Full article
Show Figures

Figure 1

17 pages, 11284 KB  
Article
Impact of Different Energy Levels of Virtual Monoenergetic Reconstructions on Radiomic Features Stability in Organic Phantom Imaging Using Photon-Counting CT
by Farroch Vahidi Noghani, Lukas T. Rotkopf, Stefan O. Schoenberg, Matthias F. Froelich, Isabelle Ayx and Alexander Hertel
Tomography 2026, 12(7), 102; https://doi.org/10.3390/tomography12070102 - 6 Jul 2026
Viewed by 349
Abstract
Objectives: This study investigates the repeatability and reproducibility of radiomic features extracted from different energy levels of virtual monoenergetic reconstruction (VMER) and polyenergetic reconstruction (PER) obtained with photon-counting computed tomography (PCCT). Methods: Sixteen organic phantoms were scanned twice in a test–retest [...] Read more.
Objectives: This study investigates the repeatability and reproducibility of radiomic features extracted from different energy levels of virtual monoenergetic reconstruction (VMER) and polyenergetic reconstruction (PER) obtained with photon-counting computed tomography (PCCT). Methods: Sixteen organic phantoms were scanned twice in a test–retest format using a 120 kV tube potential and tube currents of 10, 50, and 100 mAs. After rotating the phantoms 90° around their z-axis, additional test–retest scans were performed. A PER and 16 VMERs were generated. Segmentation and extraction of 105 original radiomic features followed. The repeatability and reproducibility of these features were assessed using the concordance correlation coefficient (CCC) for agreement and the intraclass correlation coefficient (ICC) for reliability, excluding 14 shape-based features from the analysis. Results: On average, 85 out of 91 radiomic features from VMER showed high repeatability. Approximately 30% of features demonstrated high intra-scan and inter-scan reproducibility when comparing PER and VMER. For different energy levels of VMER, around 78% showed high intra-scan reproducibility, and 74% showed high inter-scan reproducibility. Comparing the average values of test and retest scans in both the initial and rotated states revealed that 65% of features showed high agreement and 73% high reliability for PER, while for VMER, these values were 51% and 55%, respectively. Conclusions: Radiomic features from VMERs showed high test–retest repeatability, whereas reproducibility across reconstruction types and widely separated energy levels was more limited. These findings suggest that energy levels should be carefully standardized when radiomic features are extracted from PCCT-derived VMER images. Full article
(This article belongs to the Section Cancer Imaging)
Show Figures

Figure 1

14 pages, 986 KB  
Article
CT-Based Three-Dimensional Volumetric Analysis of Posterior and Lateral Malleolar Fragments in SER-Type Trimalleolar Ankle Fractures: Correlation and Reproducibility Study
by Ruhat Ünlü, Barış Yılmaz, Hasan Emirhan Usta, Hamit Çağlayan Kahraman, Gülşah Yıldırım and Celaleddin Bildik
Tomography 2026, 12(7), 101; https://doi.org/10.3390/tomography12070101 - 4 Jul 2026
Viewed by 400
Abstract
Background: Posterior malleolar fractures are commonly assessed using two-dimensional measurements and morphology-based classification systems. However, ankle fracture morphology is inherently three-dimensional, and the reproducibility of CT-based volumetric segmentation for malleolar fracture fragments has not been sufficiently established. Objectives: This study aimed to evaluate [...] Read more.
Background: Posterior malleolar fractures are commonly assessed using two-dimensional measurements and morphology-based classification systems. However, ankle fracture morphology is inherently three-dimensional, and the reproducibility of CT-based volumetric segmentation for malleolar fracture fragments has not been sufficiently established. Objectives: This study aimed to evaluate the relationship between lateral and posterior malleolar fragment volumes in homogeneous supination–external rotation (SER)-type trimalleolar ankle fractures and to assess the intraobserver and interobserver reproducibility of a manual CT-based three-dimensional volumetric segmentation workflow. Methods: This retrospective musculoskeletal imaging study included 71 patients with SER-type trimalleolar ankle fractures who underwent preoperative computed tomography (CT). Posterior and lateral malleolar fracture fragments were segmented on thin-slice axial CT images using a standardized manual contour-based slice-by-slice workflow. Fragment volumes were calculated using dedicated volumetric imaging software. The association between lateral and posterior malleolar fragment volumes was assessed using Spearman correlation and multivariable linear regression analyses. Measurement reproducibility was evaluated using intraclass correlation coefficients for absolute agreement [ICC(A,1)] and Bland–Altman analyses. Results: The median lateral and posterior malleolar fragment volumes were 8.63 cm3 (interquartile range [IQR], 7.18–10.71) and 2.64 cm3 (IQR, 1.88–4.24), respectively. A weak but statistically significant positive correlation was observed between lateral and posterior malleolar fragment volumes (Spearman rho = 0.313, p = 0.008). In multivariable linear regression analysis, lateral malleolar fragment volume remained independently associated with posterior malleolar fragment volume after adjustment for age, sex, and body mass index (B = 0.316, standardized β = 0.39, p = 0.002). Intraobserver and interobserver reproducibility were excellent for all volumetric measurements, with ICC(A,1) values ranging from 0.996 to 0.999. Bland–Altman analyses demonstrated low mean bias and narrow limits of agreement across all comparisons. Geometric agreement was also excellent, with Dice similarity coefficient values ranging from 0.93 to 0.96 across intraobserver and interobserver segmentation comparisons. Full article
Show Figures

Figure 1

13 pages, 5554 KB  
Article
Correlation Between IVIM-DWI and DCE-MRI Parameters in Soft Tissue Tumors: A Comparative Analysis of Benign and Malignant Lesions
by Ahmet Peker, Yunus Emre Senturk, Enes Muhammed Canturk and Mohammed Salman Shazeeb
Tomography 2026, 12(7), 99; https://doi.org/10.3390/tomography12070099 - 1 Jul 2026
Viewed by 316
Abstract
Objective: The objective of this study was to investigate the relationship between intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and dynamic contrast-enhanced MRI (DCE-MRI) parameters in soft tissue tumors (STTs). Methods: This retrospective study included patients with histopathologically confirmed STTs who underwent [...] Read more.
Objective: The objective of this study was to investigate the relationship between intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and dynamic contrast-enhanced MRI (DCE-MRI) parameters in soft tissue tumors (STTs). Methods: This retrospective study included patients with histopathologically confirmed STTs who underwent both DCE-MRI and IVIM-DWI between March 2022 and February 2024. Patients with prior therapy and lipomatous tumors were excluded. DCE-MRI parameters (Ktrans, Kep, Ve, iAUC) were obtained from pharmacokinetic maps using manually placed regions of interest (ROIs) in the most perfused tumor areas, avoiding necrotic and cystic regions. Corresponding ROIs were applied to IVIM-DWI maps. IVIM parameters (D, D*, f) were calculated using 11 b-values. Results: Twenty-nine patients (mean age, 56 ± 18 years; 14 malignant, 15 benign) were included. Interobserver agreement was excellent for DCE-MRI parameters, whereas IVIM-DWI parameters showed moderate-to-good agreement, with D showing the lowest reproducibility. In malignant tumors, f demonstrated strong positive correlations with Ktrans (r = 0.81, p < 0.001) and iAUC (r = 0.79, p < 0.001), both of which remained significant after correction for multiple comparisons. fD* was higher in malignant than in benign lesions in the unadjusted group comparison; however, diagnostic performance was not evaluated in the present study. No significant differences were observed for DCE-MRI parameters between benign and malignant tumors. Conclusions: IVIM-DWI parameters demonstrated associations with DCE-MRI metrics in malignant STTs and may provide complementary information regarding tumor perfusion. However, the findings should be interpreted cautiously because ROI analysis was limited to a single representative slice. Further validation using larger cohorts and volumetric tumor assessment is required. Full article
(This article belongs to the Section Cancer Imaging)
Show Figures

Figure 1

15 pages, 4294 KB  
Article
Ambient Ozone Exposure and Pneumothorax Risk After CT-Guided Lung Biopsy
by Nour Afilal, Alois Komarek, Michael Dieckmeyer, Elif Can, Martin Jonczyk, Johannes T. Heverhagen and Michael P. Brönnimann
Tomography 2026, 12(7), 98; https://doi.org/10.3390/tomography12070098 - 1 Jul 2026
Viewed by 344
Abstract
Background/Objectives: To evaluate whether day-of-procedure ambient ozone exposure is associated with pneumothorax after CT-guided lung biopsy. Methods: This retrospective single-centre study included 160 CT-guided lung biopsies performed between January 2018 and February 2026. Environmental data from the day of biopsy were assigned from [...] Read more.
Background/Objectives: To evaluate whether day-of-procedure ambient ozone exposure is associated with pneumothorax after CT-guided lung biopsy. Methods: This retrospective single-centre study included 160 CT-guided lung biopsies performed between January 2018 and February 2026. Environmental data from the day of biopsy were assigned from the nearest national monitoring station. The primary outcome was any pneumothorax on post-biopsy CT; the secondary outcome was drainage-requiring pneumothorax. Multivariable logistic regression included ozone exposure, emphysema, and access route through dependent lung area (ARDA). Ozone was analysed as a continuous variable per 10 μg/m3 and, exploratorily, using a ROC-derived threshold of ≥75.8 μg/m3. Restricted cubic splines assessed nonlinearity. Sensitivity models adjusted for needle size, biopsy system, operator identity, and season. Drainage-requiring pneumothorax was analysed using Firth logistic regression. Results: Pneumothorax occurred after 86 of 160 biopsies (53.8%), and 13 biopsies (8.1%) required drainage. Ozone was not associated with pneumothorax when modelled linearly (OR, 1.09 per 10 μg/m3; 95% CI, 0.97–1.23; p = 0.167). In exploratory threshold modelling, ozone ≥ 75.8 μg/m3 was associated with pneumothorax (OR, 2.76; 95% CI, 1.39–5.61; p = 0.004). Emphysema increased pneumothorax odds (OR, 2.16; 95% CI, 1.03–4.68; p = 0.047), whereas ARDA was protective (OR, 0.23; 95% CI, 0.11–0.45; p < 0.001). Spline analysis supported nonlinearity (p = 0.001). For drainage-requiring pneumothorax, only emphysema was significant. Conclusions: Ambient ozone showed an exploratory nonlinear association with pneumothorax after CT-guided lung biopsy, with a threshold signal around 70–80 μg/m3. ARDA was protective, whereas emphysema was associated with drainage-requiring pneumothorax. Full article
Show Figures

Graphical abstract

13 pages, 4352 KB  
Article
The Impact of Cone Beam Computed Tomography on Surgical Decision-Making and Risk Assessment in Mandibular Third Molar Extractions: A Prospective Observational Diagnostic Study
by Fatma Hande Aktemur Gürkan and Mustafa Cenk Durmuşlar
Tomography 2026, 12(7), 97; https://doi.org/10.3390/tomography12070097 - 1 Jul 2026
Viewed by 382
Abstract
Aim: This study aimed to evaluate the impact of cone beam computed tomography (CBCT) on preoperative surgical decision-making and risk assessment for mandibular third molar (MM3) extractions in cases identified as high-risk by orthopantomography (OPG). Materials and Methods: This prospective observational [...] Read more.
Aim: This study aimed to evaluate the impact of cone beam computed tomography (CBCT) on preoperative surgical decision-making and risk assessment for mandibular third molar (MM3) extractions in cases identified as high-risk by orthopantomography (OPG). Materials and Methods: This prospective observational diagnostic study utilized the purposive sampling method, recruiting 50 MM3s from 33 patients (21 females, 12 males; mean age 24.24 ± 6.77 years, range 16–42). Samples were categorized into five distinct radiographic groups based on the proximity of roots to the inferior alveolar nerve (IAN) on OPG. The methodology involved a comparative 3D analysis to determine neurovascular contact, spatial orientation, and the presence of a cortical border. Surgical strategies, specifically the necessity for coronectomy or the lingual split technique, were reassessed following 3D evaluation. Postoperative neurosensory outcomes were recorded. Statistical analysis was performed using the Fisher–Freeman–Halton and Kruskal–Wallis tests. Results: CBCT identified direct IAC contact in 74% of the cases. In 18% of the cases initially deemed high-risk by OPG, CBCT revealed a safe distance, thereby altering the surgical approach. Tooth angulation (p = 0.012) and Pell and Gregory classification (p = 0.024) were significant predictors of contact. Temporary neurosensory disturbances occurred in 4% (n = 2) of the sample, specifically in cases where CBCT had confirmed the loss of nerve canal cortication. Conclusions: In accordance with the study aim, CBCT provides essential 3D data that refines surgical planning in nearly one-fifth of high-risk cases. The findings justify selective CBCT use, guided by the ALADA principle, to minimize iatrogenic injury. Full article
(This article belongs to the Special Issue Medical Image Analysis in CT Imaging)
Show Figures

Graphical abstract

13 pages, 672 KB  
Article
A Reproducible Multicentre MRI Radiomics Workflow for Pancreatic Cyst Risk Stratification Using Paired T1- and T2-Weighted Imaging
by George Sgourakis
Tomography 2026, 12(7), 100; https://doi.org/10.3390/tomography12070100 - 1 Jul 2026
Viewed by 266
Abstract
Purpose: To develop and technically validate a reproducible multicentre MRI radiomics workflow for pancreatic cyst risk stratification using paired T1- and T2-weighted imaging from public datasets. Methods: Public datasets were screened and Cyst-X was selected as the primary cohort because it contained pancreatic [...] Read more.
Purpose: To develop and technically validate a reproducible multicentre MRI radiomics workflow for pancreatic cyst risk stratification using paired T1- and T2-weighted imaging from public datasets. Methods: Public datasets were screened and Cyst-X was selected as the primary cohort because it contained pancreatic MRI, risk labels, masks and metadata. A linked Cyst-X subset was enriched with metadata, filtered to an exact paired T1/T2 cohort, and processed through image–mask quality control, 1.0 mm isotropic resampling, intensity normalisation, PyRadiomics feature extraction, feature reduction and patient-level centre-held-out validation. The revised modelling strategy used a T2 + clinical all-patient primary analysis (n = 409) and a complete-case paired T1/T2 sensitivity analysis (n = 299). Results: The final cohort comprised 409 patients and 818 image-level rows across EMC, IU, MCF and NYU. All 818 image–mask pairs passed post-preprocessing QC. T2 radiomics were complete for all 409 patients; however, 110 T1 feature sets were missing, all from MCF. In the all-patient T2 + clinical model comparison, logistic regression achieved the highest macro-AUC (0.737). The T2 + clinical random forest comparator achieved macro-AUC 0.716 (95% CI 0.678–0.755), accuracy 0.545 (95% CI 0.496–0.592) and macro-F1 0.530 (95% CI 0.481–0.577). The paired T1/T2 complete-case random forest sensitivity model achieved macro-AUC 0.735 (95% CI 0.691–0.777), accuracy 0.575 (95% CI 0.520–0.632) and macro-F1 0.554 (95% CI 0.494–0.605). Conclusion: This study demonstrates the feasibility of constructing a reproducible public data MRI radiomics workflow for pancreatic cyst risk stratification. Model performance was modest, and independent external validation is required before clinical application. Full article
Show Figures

Graphical abstract

32 pages, 2041 KB  
Article
Efficient Uncertainty Quantification in Medical Imaging via Mamba State Space Models
by Ali Güneş
Tomography 2026, 12(7), 96; https://doi.org/10.3390/tomography12070096 - 30 Jun 2026
Viewed by 280
Abstract
Background/Objectives: Reliable uncertainty quantification (UQ) is a prerequisite for deploying automated systems in safety-critical medical imaging workflows, yet existing approaches either sacrifice computational efficiency or provide poorly calibrated confidence estimates. We present UQ-Mamba, a lightweight architecture that embeds uncertainty quantification natively into a [...] Read more.
Background/Objectives: Reliable uncertainty quantification (UQ) is a prerequisite for deploying automated systems in safety-critical medical imaging workflows, yet existing approaches either sacrifice computational efficiency or provide poorly calibrated confidence estimates. We present UQ-Mamba, a lightweight architecture that embeds uncertainty quantification natively into a Mamba state space model via linearized error propagation. Methods: UQ-Mamba yields per-prediction approximate epistemic and aleatoric uncertainty estimates in a single deterministic forward pass at only 9.5% additional inference overhead. We note that these components are heuristic approximations derived under three explicit assumptions (diagonal covariance, first-order linearization, and scalar mean-activation reduction) and have not been empirically validated as true Bayesian posteriors. By propagating learnable log-variance parameters through the SSM state transition matrix, UQ-Mamba bridges the gap between parameter efficiency and principled calibration without requiring stochastic sampling or multiple forward passes. Results: Evaluated across four medical imaging modalities—CT organ classification, colorectal histopathology, dermoscopy, and chest radiography—UQ-Mamba achieves 89.71% accuracy with ECE = 0.0217 on OrganMNIST using only 466K parameters (3.3× lower ECE than ResNet-50 at 50× fewer parameters; note that UQ-Mamba optimizes NLL, whereas ResNet-50 uses standard cross-entropy, which is a confounding factor in the ECE comparison), improves the Mamba baseline by 2.42 percentage points on PathMNIST (ECE = 0.1188 after temperature scaling), achieves 68.88% test accuracy with ECE = 0.0597 on HAM10000 dermoscopy (matching EfficientNet-B0 at 9× fewer parameters), and reaches mAUC = 0.8196 on CheXpert chest radiographs. Conclusions: Ablation studies confirm that the SSM propagation mechanism is necessary for meaningful uncertainty decomposition. These results establish uncertainty-aware SSMs as a promising proof-of-concept direction for calibrated, parameter-efficient medical image classification, with potential relevance to resource-constrained deployment settings pending further clinical validation. Full article
Show Figures

Figure 1

15 pages, 10089 KB  
Article
Virtual Bronchoscopic Pathfinder (VBP): An Open-Source Web-Based System for Airway Segmentation, Cost-Field Path Planning, and Cross-Device 3D Navigation
by Young Kim, Sunggyu Choi, Chulmin Park, Woojin Park and Doohee Lee
Tomography 2026, 12(7), 95; https://doi.org/10.3390/tomography12070095 - 29 Jun 2026
Viewed by 313
Abstract
Background/Objectives: Virtual Bronchoscopic Navigation is used to guide bronchoscopes toward peripheral pulmonary lesions, but broad clinical and research adoption remains limited by the cost of proprietary software and by segmentation failures in small distal airways that can interrupt path planning. This study presents [...] Read more.
Background/Objectives: Virtual Bronchoscopic Navigation is used to guide bronchoscopes toward peripheral pulmonary lesions, but broad clinical and research adoption remains limited by the cost of proprietary software and by segmentation failures in small distal airways that can interrupt path planning. This study presents Virtual Bronchoscopic Pathfinder, an open-source, web-based system designed to provide automated airway segmentation, robust path generation, and browser-based three-dimensional visualization. Methods: The system integrates five components: a connectivity-aware deep learning model for pulmonary airway segmentation using Connectivity-Aware Surrogate and Local-Sensitive Distance modules; TotalSegmentator for automated tumor localization; a topology-preserving three-dimensional thinning algorithm implemented in C++ for centerline extraction; a bidirectional Dijkstra algorithm operating on a three-tier anatomical cost field with centerline, airway lumen, and parenchymal costs; and a zero-footprint visualization interface built on vtk.js with synchronized axial viewing and interactive volume rendering. VBP was validated on 306 thin-section CT series from 154 subjects in the public Lung-PET-CT-Dx dataset. Results: Among the 306 CT series, 33 series (10.8%) were excluded because of scanner-specific segmentation artifacts. In the remaining 273 anatomically valid series, the system successfully generated complete end-to-end navigation paths for all cases. The overall pipeline success rate was therefore 273 of 306 series (89.2%). The web-based interface was also confirmed to operate without client-side installation across desktop, laptop, and mobile device configurations. Conclusions: Virtual Bronchoscopic Pathfinder demonstrates that a reliable and accessible virtual bronchoscopic navigation workflow can be constructed entirely from open-source components. By combining connectivity-aware segmentation, cost-field path planning, and browser-based visualization, the system provides a practical foundation for imaging informatics research and future development of intra-procedural bronchoscopic guidance. Full article
(This article belongs to the Special Issue Medical Image Analysis in CT Imaging)
Show Figures

Figure 1

15 pages, 3426 KB  
Article
Multiparametric Coronary CT Angiography-Derived Imaging Biomarkers for Risk Stratification in Nonobstructive Coronary Artery Disease: Incremental Prognostic Value in Patients with Diabetes
by Lei Chen, Hong Huang, Hao Tian, Wen-Yue Chen, Yong Wu, Hong-Yan Qiao and Jun Liu
Tomography 2026, 12(7), 94; https://doi.org/10.3390/tomography12070094 - 25 Jun 2026
Viewed by 276
Abstract
Background: Patients with diabetes mellitus and nonobstructive coronary artery disease (NOCAD) may remain at increased cardiovascular risk despite the absence of flow-limiting stenosis. Quantitative coronary CT angiography (CCTA) enables comprehensive assessment of anatomical, functional, and inflammatory imaging biomarkers beyond luminal stenosis. This study [...] Read more.
Background: Patients with diabetes mellitus and nonobstructive coronary artery disease (NOCAD) may remain at increased cardiovascular risk despite the absence of flow-limiting stenosis. Quantitative coronary CT angiography (CCTA) enables comprehensive assessment of anatomical, functional, and inflammatory imaging biomarkers beyond luminal stenosis. This study aimed to evaluate the prognostic value of an automated multiparametric CCTA-derived imaging framework for risk stratification in patients with NOCAD, with exploratory assessment in those with diabetes mellitus. Methods: This retrospective single-center study included 485 patients with NOCAD who underwent CCTA between January 2020 and December 2021. Automated CCTA analysis was performed to quantify plaque burden, high-risk plaque features, CT-derived fractional flow reserve (CT-FFR), and perivascular fat attenuation index. The primary endpoint was major adverse cardiovascular events (MACE) during follow-up. Prognostic associations were assessed using Kaplan–Meier analysis, Cox regression, and hierarchical models. Results: During a median follow-up of approximately three years, MACE occurred in 56 patients. Patients with diabetes had a higher event rate than those without diabetes. Increased plaque burden, high-risk plaque features, elevated perivascular fat attenuation index, and reduced CT-FFR were associated with adverse outcomes. The fully integrated model combining anatomical, functional, and inflammatory CCTA-derived biomarkers improved risk stratification compared with plaque-based assessment alone. Conclusions: Automated multiparametric CCTA phenotyping may provide complementary prognostic information for risk stratification in patients with NOCAD. The diabetes-specific findings should be considered exploratory and require validation in larger prospective cohorts. Full article
(This article belongs to the Section Cardiovascular Imaging)
Show Figures

Figure 1

20 pages, 2412 KB  
Article
An Efficient Cross-Modal Interaction and Dynamic Fusion Network for Multimodal Breast Ultrasound Diagnosis
by Xiangqiong Wu, Yin Lan, Lina Han and Peng Wang
Tomography 2026, 12(7), 93; https://doi.org/10.3390/tomography12070093 - 25 Jun 2026
Viewed by 319
Abstract
Background: Multimodal breast ultrasound, including B-mode imaging, color Doppler flow imaging, and elastography, provides complementary information for lesion characterization. However, effectively integrating heterogeneous modalities remains challenging due to inconsistent feature distributions, limited cross-modal interaction, computational cost in existing methods, and sensitivity to noise [...] Read more.
Background: Multimodal breast ultrasound, including B-mode imaging, color Doppler flow imaging, and elastography, provides complementary information for lesion characterization. However, effectively integrating heterogeneous modalities remains challenging due to inconsistent feature distributions, limited cross-modal interaction, computational cost in existing methods, and sensitivity to noise and missing data. Methods: We presented an efficient Cross-Modal Interaction and Dynamic Fusion Network (CIDFNet) for multimodal breast ultrasound analysis. The framework integrates a multi-scale feature enhancement module to improve modality-specific representations, a cross-modal interaction module to enable early-stage feature exchange across modalities, and a dynamic fusion strategy to adaptively combine modality information based on feature reliability estimation. In addition, an invertible neural network is incorporated to reconstruct missing modality features during training. Results: Experiments on an internal dataset of 248 patients with 1532 images show that CIDFNet obtains an AUC of 85.69%, accuracy of 75.51%, recall of 50.00%, F1-score of 62.50%, and precision of 83.33%, while requiring 49.51 M parameters and 79.79 G FLOPs, respectively. Under a simplified Gaussian noise perturbation setting, performance degradation is observed. Conclusions: CIDFNet presents a framework for multimodal breast ultrasound analysis that reflects a trade-off between performance and computational efficiency. Full article
(This article belongs to the Special Issue Imaging in Cancer Diagnosis)
Show Figures

Figure 1

19 pages, 2696 KB  
Article
Improving the Identification of the Preclinical Stages of Spinocerebellar Ataxia Type 2
by Camilo Mora-Batista, Cruz Vargas-De-León, Ramón Reyes-Carreto, Frank J. Carrillo-Rodes and José Alberto Álvarez-Cuesta
Tomography 2026, 12(7), 92; https://doi.org/10.3390/tomography12070092 - 24 Jun 2026
Viewed by 422
Abstract
Background: Spinocerebellar ataxia type 2 (SCA2) is an inherited neurodegenerative disorder characterized by progressive cerebellar degeneration. One difficulty in treating this disease lies in identifying preclinical carriers: individuals who carry the pathogenic ATXN2 mutation but remain asymptomatic with respect to motor manifestations. Though [...] Read more.
Background: Spinocerebellar ataxia type 2 (SCA2) is an inherited neurodegenerative disorder characterized by progressive cerebellar degeneration. One difficulty in treating this disease lies in identifying preclinical carriers: individuals who carry the pathogenic ATXN2 mutation but remain asymptomatic with respect to motor manifestations. Though magnetic resonance imaging (MRI) has proven valuable in supporting the diagnosis of ataxia, traditional univariate approaches using linear measurements have shown limited ability to capture the complex anatomical changes that occur across the disease spectrum, particularly during the preclinical phase. Methods: This study employed a comprehensive multivariate approach to improve the classification of individuals across the SCA2 spectrum. We developed a multinomial logistic regression model incorporating multiple linear measurements derived from magnetic resonance imaging to discriminate between healthy controls (n = 72), preclinical carriers (n = 17), and patients with manifest SCA2 (n = 61). To mitigate inherent class imbalance, particularly in the smaller preclinical subgroup, we implemented the Synthetic Minority Over-sampling Technique (SMOTE), generating a balanced dataset that enhances the model’s ability to discern the distinctive anatomical features. This was compared to the model applied to the unbalanced data. An improvement was observed when applying SMOTE. Results: The multivariate model demonstrated discriminatory performance, achieving an overall accuracy of 80.7%. The ability to identify healthy controls (AUC: 0.96), preclinical individuals (AUC: 0.75), and clinical individuals (AUC: 95%). This represents an advance over previous univariate approaches, which have had difficulty capturing the neurodegenerative changes characteristic of the preclinical stage. Conclusions: By integrating multiple neuroimaging biomarkers into a multivariable model, this study provides a tool for early identification of preclinical SCA2 carriers. The ability to accurately classify these individuals opens an opportunity for early therapeutic intervention before irreversible neurological deterioration occurs. This approach shows promise for optimizing clinical trial design and personalized care in SCA2. Full article
(This article belongs to the Section Neuroimaging)
Show Figures

Figure 1

12 pages, 2730 KB  
Article
Inter-Vendor Variability of Perfusion Parameters Derived from Dynamic Contrast-Enhanced MRI in Patients with Prostate Cancer
by Mingyu Kim, Seung Ho Kim and Joo Yeon Kim
Tomography 2026, 12(7), 91; https://doi.org/10.3390/tomography12070091 - 23 Jun 2026
Viewed by 300
Abstract
Purpose: To investigate the agreement on perfusion parameters derived from two different commercially available solutions for dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in patients with prostate cancer (PCa). Methods: A total of 50 patients (mean age, 71.6; range 56–86) who had undergone [...] Read more.
Purpose: To investigate the agreement on perfusion parameters derived from two different commercially available solutions for dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in patients with prostate cancer (PCa). Methods: A total of 50 patients (mean age, 71.6; range 56–86) who had undergone radical prostatectomy between December 2021 and September 2022 were included in this retrospective study. All patients had undergone DCE-MRI on a single 3T-MR scanner. Tumor segmentation on MR images was performed by two radiologists in consensus after radiologic-pathologic correlation using topographic maps as a reference standard. Subsequently, four perfusion parameters were calculated by dedicated commercially available solutions from two different vendors. Both solutions adopted a population-based arterial input function and an extended Tofts model as the pharmacokinetic model. The perfusion parameters were as follows; volume transfer constant (Ktrans), rate constant (kep), volume fraction of extravascular extracellular space (ve), and volume fraction of plasma (vp). The differences between paired measurements were compared by Bland–Altman analyses and the reproducibility was evaluated using the intraclass correlation coefficient (ICC). Results: The study population consisted of Gleason score (GS) 6 (n = 12), GS 7 (n = 34), GS 8 (n = 1), and GS 9 (n = 3). Significant differences were found for all parameters (p < 0.0001). Mean differences were as follows: Ktrans, −0.2102 (95% confidence interval; −0.2687 to −0.1518); kep, −0.7632 (−0.9005 to −0.6258); ve, −0.1507 (−0.2422 to −0.05907); vp, −0.02929 (−0.03383 to −0.02476). ICCs for average measures were as follows: Ktrans, 0.2989 (−0.2355 to 0.6021); kep, 0.6883 (0.4507 to 0.8231); ve, −0.1331 (−0.9967 to 0.3570); vp, 0.2653 (−0.3106 to 0.5881). Conclusion: All perfusion parameters were significantly different between the two solutions. Therefore, comparison of perfusion parameters across different solutions is not recommended. Full article
(This article belongs to the Special Issue Progress in the Use of Advanced Imaging for Radiation Oncology)
Show Figures

Figure 1

Previous Issue
Next Issue
Back to TopTop