Skip to Content
You are currently on the new version of our website. Access the old version .

6 Results Found

  • Article
  • Open Access
4 Citations
2,301 Views
11 Pages

Quantification of Thread Engagement in Screw-Plate Interface of Polyaxial Locking System Using X-ray Computed Tomography

  • Tomasz Bartkowiak,
  • Daria Madalińska,
  • Patryk Mietliński,
  • Jakub Kaczmarek and ,
  • Bartosz Gapiński,
  • Marcin Pelic and
  • Piotr Paczos
  • + 2 authors+ 0 author

30 August 2023

This study demonstrates a new method for quantifying thread engagement in mechanical connections and verifies its applicability using biomedical implants under push-out tests. The focus is on orthopedic plate implants employed for bone fracture fixat...

(This article belongs to the Special Issue Material, Design and Biological Studies of Bones & Implants)
  • Article
  • Open Access
598 Views
20 Pages

Biomechanical Evaluation of Patient-Specific Titanium Fixation Systems for Segmental Le Fort I Osteotomy: A Finite Element Analysis

  • Neculai Onică,
  • Elena-Raluca Baciu,
  • Cezara Andreea Onică,
  • Florin-Emilian Țurcanu and ,
  • Geta-Mirela Ispas,
  • Vlad Nicolae Arsenoaia,
  • Loredana Golovcencu and
  • Alice Murariu
  • + 3 authors+ 0 author

7 September 2026

Patient-specific Ti–6Al–4V fixation systems are increasingly used to stabilise the maxilla following segmental Le Fort I osteotomy; however, the biomechanical responses of complete locking and non-locking patient-specific fixation configu...

(This article belongs to the Special Issue State of the Art: Biomaterials in Bone Implant and Regeneration (2nd Edition))
  • Article
  • Open Access
7 Citations
2,801 Views
15 Pages

Influence of Screw Angulation on the Mechanical Properties on a Polyaxial Locking Plate Fixation

  • Gabriel Martínez-Fortún,
  • Alejandro Yánez and
  • Alberto Cuadrado

Polyaxial locking systems are widely used for strategic surgical placement, particularly in cases of osteoporotic bones, comminuted fractures, or when avoiding pre-existing prosthetics. However, studies suggest that polyaxiality negatively impacts sy...

(This article belongs to the Section Biomedical Engineering and Biomaterials)
  • Article
  • Open Access
6 Citations
6 Pages

The Use of 2.4-mm Locking Plate System in Treating Comminuted Mandibular Fracture by Firearm

  • Cassiano Costa Silva Pereira,
  • Pâmela Letícia dos Santos,
  • Ellen Cristina Gaetti Jardim,
  • Idelmo Rangel Garcia Júnior and ,
  • Elio Hitoshi Shinohara and
  • Marcelo Marotta Araujo
  • + 1 author+ 0 author

Maxillofacial trauma caused by firearms has considerably increased, in which the mandibular body is the site of highest incidence of firearm projectiles. In these cases, the use of titanium plates and screws allows the early restoration of form and f...

  • Article
  • Open Access
1 Citations
1,900 Views
14 Pages

A Human Self-Locking Cone Morse Connection Retrieved After 30 Years: A Histological and Histomorphometric Case Report

  • Carlo Mangano,
  • Margherita Tumedei,
  • Adriano Piattelli,
  • Francesco Guido Mangano and ,
  • Tea Romasco,
  • Natalia Di Pietro and
  • Giovanna Iezzi
  • + 2 authors+ 0 author

20 March 2025

The Cone Morse (CM) implant-abutment junction is designed to improve screw mechanics and minimize bacterial leakage through a process known as “cold fusion”. This research evaluated a clinically stable self-locking CM implant that was ret...

  • Article
  • Open Access
17 Citations
7,859 Views
12 Pages

14 June 2020

This study proposes a novel titanium 3D printing patient-specific implant: a lightweight structure with enough biomechanical strength for a distal femur fracture with segmental large defect using nonlinear finite element (FE) analysis. CT scanning im...

(This article belongs to the Section Materials Science and Engineering)