Skip to Content
FluidsFluids
  • Article
  • Open Access

21 November 2026

24 Pages

Structural and Hemodynamic Performance of a Polyurethane Prosthetic Aortic Valve

,
and
Biomedical, Industrial and Human Factors Engineering, Wright State University, 3640 Col. Glen Hwy, Dayton, OH 45435, USA
*
Author to whom correspondence should be addressed.
Fluids2026, 11(12), 303;https://doi.org/10.3390/fluids11120303 
(registering DOI)
This article belongs to the Special Issue Advances in Hemodynamics and Related Biological Flows, 2nd Edition

Abstract

Computational modeling has become an essential tool for evaluating prosthetic heart valve performance prior to experimental and clinical investigations. The objective of this study was to evaluate the structural response and hemodynamic performance of a tricuspid polyurethane prosthetic aortic valve using finite element analysis (FEA) and computational fluid dynamics (CFD). A three-dimensional valve model was developed in SolidWorks and analyzed in SimScale under physiologically representative loading conditions. The structural simulations quantified leaflet deformation, strain, and von Mises stress distributions, while the CFD simulations assessed pressure distribution, velocity fields, turbulent kinetic energy, wall shear stress, and flow streamlines through the valve in its fixed-open configuration with a k–ω SST turbulence model. The maximum leaflet displacement was 2.07 mm, with a peak von Mises stress of 1.19 MPa and a peak shear strain component (EPXY) of 6.70 × 10−2, primarily localized near the commissural attachment regions. The CFD analysis yielded a maximum axial Y-velocity component of 2.93 m/s and a maximum three-dimensional velocity magnitude of 3.10 m/s. The simplified Bernoulli estimate based on the velocity magnitude was 38.44 mmHg (34.34 mmHg when based on the axial component); these are velocity-derived estimates rather than directly calculated CFD pressure differences. The simulations also showed localized turbulent kinetic energy and localized wall shear stress concentrations near the leaflet free edges. The combined structural and hemodynamic results indicate that the proposed polyurethane valve geometry exhibits controlled leaflet deformation and stable flow characteristics under the prescribed loading conditions, within the limits of a linear elastic leaflet model and a rigid, fixed-open CFD model that does not capture valve dynamics. These findings demonstrate the feasibility of an independent computational framework for preliminary prosthetic valve evaluation and the provide baseline data for future experimental validation and fluid–structure interaction studies.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.