Skip to Content
PhotonicsPhotonics
  • Article
  • Open Access

31 March 2026

13 Pages

Additive Manufacturing Based Polymer Compounded Refractive Lenses for X-Ray Focusing at Synchrotron Light Sources

,
,
,
,
,
and
1
Center of Transformative Science, ShanghaiTech University, Shanghai 201210, China
2
School of Physical Science and Technology, ShanghaiTech University, Shanghai 201210, China
*
Authors to whom correspondence should be addressed.

Abstract

Additive manufacturing offers a promising route to low-cost, rapidly deployable X-ray focusing optics with geometries that are difficult to realize by conventional machining. Here, we report polymer compound refractive lenses (CRLs) for hard X-ray focusing fabricated by projection micro-stereolithography (PµSL, DLP-based) and by two-photon polymerization (2PP). Two-dimensional bi-parabolic CRL elements were produced in multiple photopolymer resins (HTL, Tough, ST1400 for PμSL; IP-S for 2PP) and evaluated by at-wavelength metrology at the Shanghai Synchrotron Radiation Facility. The single-lens residual phase errors (RMS) less than 0.1 λ were measured for PµSL-fabricated HTL, and Toughlenses, respectively, while 2PP-fabricated IP-S lenses achieved 0.008 λ . And the analysis indicates that PµSL lenses are primarily limited by systematic mid-order aberrations, whereas 2PP substantially suppresses coma but shows residual spherical aberration attributable to process calibration and shrinkage. Leveraging the higher fidelity of 2PP, a 65-element parabolic CRL array (radius of curvature of 100 µm) was fabricated and demonstrated hard X-ray focusing at 15 keV with focal spot sizes of 6.4 ± 1 µm (H) and 6.8 ± 1 µm (V), and a flux gain of 220. The measured performance agrees with theoretical expectations when accounting for X-ray source properties, detector resolution and chromatic aberration. These results establish a practical pathway for additively manufactured polymer CRLs with DLP and 2PP techniques as compact, customization focusing optics for synchrotron beamlines.

1. Introduction

Advanced X-ray light sources with high brightness and coherence have been widely used in scientific research, including materials science, physics, biomedical fields, and industrial applications. Along with the development of light sources, optics for X-ray beam manipulation, such as focusing, tuning, monochromatization, and shaping, have been the key components in fully utilizing the extraordinary properties of X-ray light, especially X-ray focusing optics. Reflective mirrors are the most commonly used focusing optics for micro-scale or nano-scale focusing. Although numerous X-ray focusing schemes have been proposed over the subsequent decades, Kirkpatrick–Baez (KB) mirrors are still widely used in large-scale X-ray light source facilities, including synchrotron radiation sources and free-electron lasers. However, X-ray mirrors rely on atomic fabrication technologies; for example, a height profile of the mirror surface with a 1 nm peak-to-valley error is essential for diffraction-limited light sources. Therefore, difficulties in fabrication and metrology for high-quality X-ray mirrors have been the main challenge. Compared with reflective mirrors, X-ray Compounded Refractive Lenses (CRLs) have attracted a lot of attention since their first proposal [1] due to advantages such as low cost, flexibility, easier fabrication, and compactness. In terms of design, X-ray refractive optical components adopt one-dimensional [2] and two-dimensional profile designs [3], among which the most widely used types include spherical [1], parabolic, and kinoform [4]. Based on these designs, CRLs fabricated from high delta-to-beta ratio materials such as Be, Al, Si, Ni, and diamond have gained significant attention and are widely used in synchrotron radiation sources around the world [5,6]. Among them, Beryllium CRLs are the most popular, considering their low absorption, high refractive index, and low scattering. However, Be CRLs impose extremely high requirements on the purity of beryllium to reduce X-ray scattering [7].
The silicon CRLs fabricated via advanced lithography and etching technology are superior in resolution to Be-based CRLs and achieve a minimum focal spot size down to 50 nm with a 1D array. However, the high X-ray absorption of silicon for hard X-rays imposes significant limitations on beam flux, resulting in extremely low focusing efficiency. Furthermore, the one-dimensional contour design inherently limits their capability for two-dimensional imaging of objects.
Additive Manufacturing (i.e., 3D printing) provides great flexibility in the fabrication of 3D structures for complicated components. After decades of development, the resolution of 3D printing technology has reached the sub-micrometer scale. 3D printing technology features integral forming, which enables the fabrication of special surface profiles that are difficult to process via traditional manufacturing processes and offers shorter fabrication cycles compared to other processing methods. Meanwhile, 3D printing materials derived from 3D printing technology are also thriving. Amorphous polymeric materials, represented by photosensitive resins, have achieved a balance in cost, precision, and plasticity. Therefore, amorphous polymeric CRLs via 3D printing provide a feasible way to fabricate CRLs with controllable costs, short fabrication cycles, excellent beam flux, and customizable surface profiles.
Digital Light Processing (DLP) and Two-Photon Polymerization (2PP) are two typical 3D printing techniques. DLP is a high-efficiency 3D printing technology widely used in industrial production, and many advanced technologies have been derived from DLP, among which Projection Micro Stereolithography (PµSL) [8]—a technique employing a Digital Micromirror Device (DMD) as a dynamic mask-has been extensively applied, with a maximum resolution of 0.6 µm. This technology balances printing precision and printing speed and has been rapidly adopted in the research and development of metamaterials [9,10]. Two-Photon Polymerization (2PP)-induced lithography technology was proposed in 1997 [11]. This method is simple and reliable, offering a wide range of processable materials, and is currently one of the 3D additive manufacturing technologies with the highest precision. The feature size of 3D structures fabricated via this method can be smaller than 100 nm [12]. To date, several research groups have reported polymer CRLs fabricated using 2PP-induced lithography technology [13,14]. In the design of these CRLs, tower-type and train-type configurations have been adopted. Additionally, some groups have integrated zone plates with tower-type CRLs to fabricate apochromatic lenses. Although the spatial resolution is only 480 nm, their chromatic aberration-free range has been significantly improved compared with traditional lenses [15].
Although the 2PP-induced lithography provides high spatial resolution, fabrication efficiency remains an obstacle for producing highly focusing CRLs, which require hundreds of CRL elements and several days of fabrication time. In comparison, DLP technology offers an advantage in fabrication efficiency at the cost of spatial resolution, but, to our knowledge, there are no reports on DLP-based CRLs. In this paper, we present two-dimensional parabolic X-ray CRLs developed from amorphous polymers via PµSL and 2PP technologies. The two types of CRLs were experimentally compared at a synchrotron light source, showing that DLP-based CRLs exhibited higher but acceptable thickness errors. Additionally, a large-aperture, high-efficiency train-type parabolic X-ray CRL was developed using 2PP lithography. Its thickness error was characterized using the X-ray speckle tracking method, and the focusing performance and beam flux gain coefficient of the 2PP-fabricated train-type parabolic X-ray CRL were tested at a synchrotron radiation source. The results demonstrate the potential application of highly focusing optics using 2PP technology.

2. Materials and Methods

According to the paraxial approximation for parabolic X-ray CRLs [16], the focusing characteristics and focal length of CRLs can be calculated using the following formula:
f = R 2 N δ
where R denotes the radius of curvature of the parabolic surface, N represents the number of bi-parabolic surface, and δ is the material’s refractive index.
Generally speaking, the materials selected for CRLs should possess good hardness and thermal stability to ensure their continuous operation under X-ray irradiation. Considering the differences in operating wavelengths between PµSL and 2PP lithography, the photopolymer resins used for them also differ. For PµSL, we selected three materials: Tough, HTL, and ST1400, which are provided by Boston Micro Fabrication [17]. For 2PP lithography, we adopted the IP-S material from Nanoscribe (Eggenstein-Leopoldshafen, Germany). The comparison of various parameters of these materials is shown in Table 1:
Table 1. Mechanical and Physical Properties of Different Materials.

2.1. Development of CRLs Under the PµSL Process

3D printing based on PµSL utilizes Computer-Aided Design to slice a three-dimensional model into two-dimensional planar patterns, which are then input into a Digital Micromirror Device (DMD) [8]. The DMD modulates the patterns according to the 2D planar designs and projects the modulated patterns onto the photopolymer resin in the form of UV light passing through a lens, triggering local photopolymerization of the resin. This completes the printing of one 2D planar layer. The process is repeated as the stage moves, ultimately completing the fabrication of the entire structure.
In terms of design, we adopted the parabolic configuration [4] with a radius of curvature R of 160 µm selected. For the ST1400 material, due to its relatively higher viscosity compared to HTL and Tough, the original thin shell was replaced with a uniform-width rectangular shell to avoid deformation during the printing process Figure 1. The design was entrusted to BMF Precision Tech for sample fabrication, with the requirements of a lateral resolution of 2 µm and a 2D planar slicing layer thickness precision of 5 µm, which represents the highest accuracy achievable for the DLP 3D printing technique. Preliminary observations of the fabricated biparabolic lenses were conducted using a Scanning Electron Microscope (SEM), Figure 1. Under a 100 µm scale bar, obvious layer lines were observed in all three materials, and significant deformation occurred in the devices themselves. We attribute this phenomenon to the insufficient release of internal stresses during the printing process.
Figure 1. 2D parabolic CRL fabricated with PµSL technology. (a) Cross-Sectional Views of HTL/Tough and ST1400 (mm); SEM Images at 50 µm Scale: (b,c) HTL, (d,e) Tough, (f,g) ST1400.

2.2. Development of CRLs with the 2PP

Two-photon Polymerization Lithography is based on the process of triggering the photopolymerization of photopolymer resin via the two-photon absorption effect, wherein the photopolymer resin can absorb two photons simultaneously. The polymerization threshold in this process enables the resolution to reach the 100 nm scale. Sample fabrication was conducted at the Soft Matter Nanofab of ShanghaiTech University using a Photonic Professional GT2 (PPGT2) manufactured by Nanoscribe. This equipment offers a minimum lateral resolution of 160 nm and a minimum 2D planar slicing layer thickness of 100 nm. Samples were fabricated using IP-S photopolymer resin under the Dip-in lithography mode, with an objective lens of 25× (NA = 0.8).
Owing to the ultra-high precision and point-by-point fabrication of the 2PP lithography process, its manufacturing time is relatively prolonged. Fabricating samples strictly following the design of the PµSL process would result in insufficient release of internal stresses. Meanwhile, considering that the viscosity of IP-S photopolymer resin is much higher than that of the three materials used in PµSL, we observed that during the fabrication of microstructures via 2PP lithography, insufficient support due to the excessively small spacing between biparabolic surfaces may lead to the structural collapse of the upper curved surface under its own weight before the complete structure is printed. Therefore, targeted structural optimization was performed for the 2PP-fabricated CRLs Figure 2. An arc-shaped base is introduced to mitigate the effect of internal stresses, and a trapezoidal design is adopted to provide support for the upper curved surface. Additionally, the radius of curvature R is restricted to 130 µm, and the required number of biparabolic elements for a controllable focal length can be recalculated according to Equation (1). The main reactive groups of IP-series photopolymer resins are acrylates (C14H18O7), and the density of IP-S photopolymer resin is 1.19 g/cm3. Considering that material density is very close to that of the original SU-8 photopolymer resin (1.2 g/cm3), the refractive index of IP-S photopolymer resin was approximated using the empirical formula for SU-8 [18], where δ denotes the real part of the refractive index decrement, and E represents the X-ray energy.
δ = 0.00027142 keV 2 · 1 E keV 2
Figure 2. 2D parabolic CRL fabricated with 2PP technology. (a) Design of 2PP. Characterization of IP-S CRLs: (b) 200 µm Scale (c) 30 µm Scale, (d) 10 µm Scale.
For the fabrication of CRLs, fused silica substrates coated with Indium Tin Oxide (ITO) were used, and IP-S photopolymer resin was dropped onto the ITO-coated side. During preprocessing, to balance the precision and speed of sample fabrication, the horizontal slicing precision was set to 1 µm. For vertical slicing, the adaptive function of the equipment was enabled, allowing it to automatically achieve the maximum resolution of the 25× objective lens on curved surfaces. The effective field of view of the 25× objective lens is approximately 400 µm, and the limited field of view restricts the geometric dimensions of the CRLs. To ensure the precision and reliability of the devices, the device dimensions were controlled within the range of the effective field of view. After printing, the devices were subjected to a development process with Propylene Glycol Methyl Ether Acetate (PGMEA) for 18 min, followed by immersion in isopropanol for 1 min to remove excess developer. Ultimately, a set of horizontally arranged CRLs was obtained, consisting of 65 individual biparabolic lenses with a radius of curvature of 100 µm and a spacing of 10 µm between the base of each lens, and with the spacing between the effective functional curved surfaces of the lenses being 150 µm. The total printing time for the entire CRL assembly was 8 h. Meanwhile, individual devices were also fabricated for surface profile characterization. Observations under a Scanning Electron Microscope (SEM), Figure 2, clearly demonstrate the significant precision advantage of 2PP lithography. At a 30 µm scale bar, the layer lines of the devices are significantly finer compared with those fabricated via the PµSL process. Furthermore, thanks to the improved design, no obvious deformation of the devices was observed in the 2PP-fabricated samples, which makes us highly anticipate the practical performance of 2PP lithography under X-ray irradiation.

2.3. Experimental Setup

The 3D printed CRLs were experimentally characterized at the BL13HB beamline of the Shanghai Synchrotron Radiation Facility (SSRF). Figure 3 shows the schematic of the experimental setup. The BL13HB beamline provides a hard X-ray beam with an energy range of 8–40 keV using a double multilayer monochromator (DMM) with a bandwidth of ∼1.5%. Due to differences in experimental plans, X-rays with an energy of 12.4 keV were used for data acquisition of samples fabricated via the PµSL process, while 15 keV X-rays were used for those fabricated via 2PP lithography. A 2D array detector (Hamamatsu Flash 4.0, Hamamatsu Photonics, Hamamatsu City, Japan), a 10× objective, a tube lens, and a LuAG:Ce scintillator with a thickness of 50 µm were used for high-resolution imaging data collection, giving an effective pixel size of 0.65 µm. Due to the limited NA of the objective and the point spread function of the scintillator, the spatial resolution of the detector system is estimated to be around 2 µm.
Figure 3. Experimental setup of Speckle-based imaging and focusing characterization for at-wavelength metrology of CRLs. (a) Speckle tracking for at-wavelength metrology of single CRL; (b) focusing characterization of CRLs array.
The X-ray speckle tracking method was used for the at-wavelength metrology of the CRLs. A binary random coded mask with a pitch size of 5 µm was inserted before the CRLs to generate speckle patterns [19,20]. The distance from the coded mask to CRLs and the distance from CRLs to the detector are 325 mm and 435 mm, respectively. To characterize the thickness error of the CRL with high accuracy and resolution, the binary mask was scanned in both the X and Y directions with a step size of 3 µm and a grid of 10 × 10. Then the 2D phase or thickness was reconstructed using the speckle reconstruction algorithm. Here, the Wavelet Transform-based Speckle Vector Tracking (WSVT) is used to reconstruct the phase of the under-test optics [21]. This method enables controllable noise suppression via different cutoff coefficients, and can achieve faster scanning speeds when processing large-sized images and phase shifts without sacrificing reconstruction quality. WSVT is capable of acquiring the absorption and dark-field signals of samples, possesses a high angular dynamic range, and thus serves as an excellent tool for testing focusing optical components. For the focusing characterization of the CRLs array, the 2D detector system with the mentioned 2 µm resolution was used to directly image the focal spot, which is shown in Figure 3b.

3. Results and Discussion

3.1. Comparison of the Phase Aberration of the CRLs

The WSVT was used to analyze the speckle tracking images and reconstruct the 2D phase of the single CRL fabricated via DLP technology for the materials HTL, Tough, and ST1400, and the CRL fabricated with the 2PP technique for the material IP-S. Then the second-order phase was subtracted from the raw 2D phase to obtain the phase error. 80% of the aperture size of the device was selected as the analysis region, and finally, the residual map of each device was shown in Figure 4. The RMS and PV residual phase errors of the HTL, Tough, ST1400 and IP-S materials are 0.023 λ /0.135 λ , 0.020 λ /0.134 λ , 0.092 λ /0.586 λ and 0.008 λ /0.150 λ . Among the three materials, the ST1400 shows the largest error compared with the HTL and Tough, which may be caused by the relatively lower elastic modulus. It can be intuitively concluded that the IP-S material exhibits a significantly more uniform residual distribution in the transmission image and the residual phase. A phase aberration of λ / 14 is generally regarded as the minimum precision standard for practically usable X-ray optical components. Although the HTL and Tough materials give slightly higher errors, the RMS residual phase error is acceptable for X-ray CRL applications. Meanwhile, from the residual maps, we can observe that due to the influence of layer lines, the single devices fabricated via DLP printing exhibit a regular distribution of surface profile errors. However, there is no obvious phase structure related to the laser line shown in the transmission image. Considering that X-ray speckle tracking is not sensitive to phase jumping, it is reasonable that the residual phase did not show the layer artifact. However, this layer error distribution is highly likely to induce intense X-ray scattering effects during the focusing process.
Figure 4. Transmission images and residual phase after removing the second-order phase of single CRL with different materials: (a,b) HTL; (c,d) Tough; (e,f) ST1400; (g,h) IP-S.
In addition, the Zernike analysis was performed on the residual phase, and the surface profile errors of the devices were assessed via Zernike polynomials (Figure 5). The first six low-order terms of the Zernike fitting were masked during the 2D phase unwrapping process, and we mainly focus on the impact of the middle-order terms on the RMS of the devices.
Figure 5. Zernike analysis results of single CRL with different materials: (a) HTL; (b) Tough; (c) ST1400; (d) IP-S.
For the Z7-Z15 terms, the following definitions apply: Z7/Z8 are considered to represent the X/Y-direction primary coma, Z9/Z10 denote high-order coma, Z11 corresponds to primary spherical aberration, Z12/Z13 are orthogonal terms representing secondary astigmatism, and Z14/Z15 are also orthogonal terms corresponding to fourth-order distortion. For X-ray optical devices, low-order errors have a more significant impact. CRLs fabricated via the PµSL process all have RMS values below 0.1 λ , but the three materials exhibit relatively high primary coma. Although the Tough and HTL samples have relatively similar RMS values, the HTL sample performs relatively poorly, with larger spherical aberration and secondary astigmatism. ST1400 shows an extremely large coma, and its RMS value indicates that devices made from this material are not particularly suitable for use under X-ray irradiation due to precision issues. The large coma may be related to the processing precision provided by the PµSL process in the Z-direction, which is also a persistent challenge for projection-based 3D printing methods such as DLP.
Devices fabricated from IP-S photopolymer resin via the 2PP lithography process exhibit a significant advantage in RMS value compared to the previous three materials, with a precision an order of magnitude higher than that of ST1400. Compared to the three PµSL fabricated samples, the IP-S sample has essentially eliminated primary coma, retaining only partial high-order coma, thus showing distinct superiority over DLP technology. However, it is also observed that the IP-S sample exhibits relatively large primary spherical aberration, indicating that the parabolic design was not well reproduced during printing. Meanwhile, similar fluctuations are observed in the orthogonal terms Z12/Z13 and Z14/Z15. This phenomenon may be related to the precision of the equipment’s horizontal translation stage and the material’s shrinkage coefficient, which can be the focus of subsequent optimization work. The results of Zernike fitting are consistent with the initial expectations. CRLs fabricated via the 2PP lithography process exhibit a more favorable RMS value compared to those fabricated via the PμSL process, thereby being more in line with the practical application requirements under X-ray irradiation.

3.2. Focusing Performance of CRL Array Fabricated via the 2PP Lithography Process

Considering that the accuracy of the 2PP technique is significantly higher than the DLP method, an array of 65 CRLs with a radius of 100 µm was fabricated to achieve high focusing at hard X-rays. The experiment was performed with an energy of 15 keV at the BL13HB beamline at the Shanghai Synchrotron Radiation Facility (SSRF). The experimental setup is illustrated in Figure 3b.
On the basis of the CRL surface profile characterization experiment, the binary-coded mask was removed, and a slit was used to restrict the X-ray beam size transmitted to the detector. The closest distance from the CRLs to the detector was 435 mm. The detector was moved from its closest position to the farthest position in steps of 2 mm, and three images were acquired at each position for averaging. Throughout the experiment, it was confirmed that the 65-element CRL array remained under X-ray irradiation, and no obvious damage was observed on the 65-element CRL array exposed to 15 keV X-rays for several hours. For the focal spot analysis, the full-width at half maximum (FWHM) spot size is calculated, and the focal length is then derived based on the corresponding moving distance of the detector. Additionally, the beam flux gain coefficient is calculated from the with/without CRL images after removing the background. The final experimental data are presented in Figure 6.
Figure 6. Focusing properties of the CRLs array. (a) 2D image of the focal spot at the position of maximum beam flux gain value; (b) beam flux gain value after passing through the CRL; (c) horizontal focal size (FWHM) vs. CRL distance; (d) vertical focal size (FWHM) vs. CRL distance; (e) horizontal 2D slice of the focal spot vs. CRL distance; (f) vertical 2D slice of the focal spot vs. CRL distance.
Figure 6c,d show the focal spot sizes (FWHM) of the 65-element CRL array in the horizontal and vertical directions, respectively. The minimal size in the horizontal direction is 6.4 ± 1 μ m, and the minimal size in the vertical direction is 6.8 ± 1 μ m. Through calculation, the maximum beam flux gain value of 220 was measured at a distance of 615 mm, as shown in Figure 6b. In both the horizontal and vertical directions, the 65-element CRL array exhibited a phenomenon of focal point separation (at the position of the minimum FWHM), with the focal point at 643 mm in the horizontal direction and 598 mm in the vertical direction. Combined with the analysis of the Zernike fitting results mentioned above, this phenomenon is primarily attributed to the influence of primary astigmatism aberration. In particular, the primary spherical aberration is effectively amplified in the 65-element CRL array. To minimize the impact of primary spherical aberration, accurate calibration should be performed on the 2PP lithography process.
According to Equation (1), the theoretical focal length of the 65 CRL array at 15 keV is 637.6 mm, while the measured focal lengths for the horizontal and vertical directions are 643 mm and 598 mm, respectively. Considering the presence of significant astigmatism aberration, it is reasonable that the measured vertical focal length is shorter than the theoretical value. For the focal spot size, the theoretical focal spot size can be calculated by combining the geometric magnification of the source size S g , diffraction-limited size S d , imaging detector resolution S r , and chromatic aberration S c : S = S g 2 + S d 2 + S r 2 + S c 2 . As described in the experimental setup section, the 65 CRL array was measured at an X-ray energy of 15 keV with a bandwidth of 1.5%. The horizontal and vertical source sizes ( σ H / σ V ) at BL13HB are 51.73 µm and 26.11 µm, respectively, and the source to CRL array distance p is 35 m. According to the measured focal length of the CRL array, the geometric sizes (FWHM) are 2.28 µm (H) and 1.07 µm (V). Considering that the CRL aperture A is 200 µm, the diffraction-limited sizes S d are 0.24 µm (H) and 0.22 µm (V). The imaging detector resolution was estimated as 2 µm based on the NA of the objective and scintillator thickness. Since the double multilayer monochromator was used to set the X-ray energy during the experiment, chromatic aberration significantly restricts the focal spot size. Theoretically, the focal size induced by chromatic aberration can be calculated as S c = A Δ f f p p + f , where f is the focal length. According to the above analysis, the theoretical focal sizes S (FWHM) of the CRL array are 6.73 µm (H) and 6.42 µm (V). The measured minimal focal sizes are 6.4 µm (H) and 6.8 µm (V), which agree with the theoretical values, indicating good fabrication quality of the CRLs array.

4. Conclusions

In conclusion, we demonstrated additively manufactured polymer compound refractive lenses (CRLs) for hard X-ray focusing and performed an experimental comparison between projection micro-stereolithography (PµSL, DLP-based) and two-photon polymerization (2PP). Single PµSL lenses in HTL and Tough resins achieved acceptable residual phase errors (RMS value is 0.02 λ ), whereas ST1400 showed substantially larger aberrations. SEM and phase maps indicate that layer-wise artifacts, Z-direction limitations, and resin-dependent warping can introduce systematic figure errors that may accumulate in long CRL arrays and increase scattering. 2PP fabrication in IP-S produced significantly higher figure fidelity (RMS residual phase is 0.008 λ ) and avoided the macroscopic deformation observed in PµSL parts. Zernike analysis suggests coma is largely suppressed in 2PP lenses, while residual spherical aberration and astigmatism likely arise from process calibration and polymer shrinkage. A 65-element 2PP train-type CRL array demonstrated focusing at 15 keV with 6.4 ± 1 µm (H) and 6.8 ± 1 µm (V) spots and a peak flux gain of 220, consistent with the theoretical values. Although the ultra-long geometry increases spherical aberration, it can be mitigated through process optimization or aberration compensation. Future work focuses on the long-term stability of 2PP polymer CRLs across broader hard X-ray energies and the focusing geometry with complicated 3D structures for X-ray beam manipulation.

Author Contributions

Conceptualization, Z.Q.; methodology, B.W. and R.Y.; validation, Z.Q.; formal analysis, B.W. and R.Y.; investigation, B.W.; data curation, B.W., P.W., R.Y. and Z.G.; writing—original draft preparation, B.W.; writing—review and editing, B.W. and Z.Q.; visualization, B.W. and R.Y.; supervision, Y.T., Z.Q. and H.J.; funding acquisition, Z.Q. and H.J. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by National Natural Science Foundation of China (12305363, 12575346); Shanghai Rising-Star Program (23QA1406700); STCSM No. 24JD1402200.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding authors.

Acknowledgments

We acknowledge the Shanghai Synchrotron Radiation Facility (SSRF) of BL13HB for the provision of experimental facilities, and thank for the assistance on X-ray speckle tracking measurements. We thank Soft Matter Nanofab (SMN180827) at ShanghaiTech University for support in sample fabrication. The X-ray measurements were performed at the BL13HB beamline of the Shanghai Synchrotron Radiation Facility.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
DLPDigital light processing
2PPTwo-photon polymerization
PµSLProjection micro stereolithography
WSVTWavelet speckle vector tracking
CRLCompounded refractive lens

References

  1. Snigirev, A.; Kohn, V.; Snigireva, I.; Lengeler, B. A compound refractive lens for focusing high-energy X-rays. Nature 1996, 384, 49–51. [Google Scholar] [CrossRef] [Scilit]
  2. Snigirev, A.; Snigireva, I.; Grigoriev, M.; Yunkin, V.; Di Michiel, M.; Kuznetsov, S.; Vaughan, G. Silicon planar lenses for high-energy x-ray nanofocusing. In Proceedings of the Advances in X-Ray/EUV Optics and Components II; SPIE: Bellingham, WA, USA, 2007; Volume 6705, pp. 39–49. [Google Scholar]
  3. Lengeler, B.; Schroer, C.; Tümmler, J.; Benner, B.; Richwin, M.; Snigirev, A.; Snigireva, I.; Drakopoulos, M. Imaging by parabolic refractive lenses in the hard X-ray range. Synchrotron Radiat. 1999, 6, 1153–1167. [Google Scholar] [CrossRef] [Scilit]
  4. Lengeler, B.; Schroer, C.G.; Kuhlmann, M.; Benner, B.; Günzler, T.F.; Kurapova, O.; Zontone, F.; Snigirev, A.; Snigireva, I. Refractive X-ray lenses. J. Phys. D Appl. Phys. 2005, 38, A218. [Google Scholar] [CrossRef] [Scilit]
  5. Lyubomirskiy, M.; Schroer, C. Refractive lenses for microscopy and nanoanalysis. Synchrotron Radiat. News 2016, 29, 21–26. [Google Scholar] [CrossRef] [Scilit]
  6. Snigireva, I.; Vaughan, G.; Snigirev, A. High-Energy Nanoscale-Resolution X-ray Microscopy Based on Refractive Optics on a Long Beamline. In Proceedings of the AIP Conference Proceedings; American Institute of Physics: Melville, NY, USA, 2011; Volume 1365, pp. 188–191. [Google Scholar]
  7. Lyatun, I.; Ershov, P.; Snigireva, I.; Snigirev, A. Impact of beryllium microstructure on the imaging and optical properties of X-ray refractive lenses. Synchrotron Radiat. 2020, 27, 44–50. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Sun, C.; Fang, N.; Wu, D.; Zhang, X. Projection micro-stereolithography using digital micro-mirror dynamic mask. Sens. Actuators A Phys. 2005, 121, 113–120. [Google Scholar] [CrossRef] [Scilit]
  9. Zheng, X.; Lee, H.; Weisgraber, T.H.; Shusteff, M.; DeOtte, J.; Duoss, E.B.; Kuntz, J.D.; Biener, M.M.; Ge, Q.; Jackson, J.A.; et al. Ultralight, ultrastiff mechanical metamaterials. Science 2014, 344, 1373–1377. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Zheng, X.; Smith, W.; Jackson, J.; Moran, B.; Cui, H.; Chen, D.; Ye, J.; Fang, N.; Rodriguez, N.; Weisgraber, T.; et al. Multiscale metallic metamaterials. Nat. Mater. 2016, 15, 1100–1106. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Maruo, S.; Nakamura, O.; Kawata, S. Three-dimensional microfabrication with two-photon-absorbed photopolymerization. Opt. Lett. 1997, 22, 132–134. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Paz, V.F.; Emons, M.; Obata, K.; Ovsianikov, A.; Peterhänsel, S.; Frenner, K.; Reinhardt, C.; Chichkov, B.; Morgner, U.; Osten, W. Development of functional sub-100 nm structures with 3D two-photon polymerization technique and optical methods for characterization. J. Laser Appl. 2012, 24, 042004. [Google Scholar] [CrossRef] [Scilit]
  13. Petrov, A.; Bessonov, V.; Abrashitova, K.; Kokareva, N.; Safronov, K.; Barannikov, A.; Ershov, P.; Klimova, N.; Lyatun, I.; Yunkin, V.; et al. Polymer X-ray refractive nano-lenses fabricated by additive technology. Opt. Express 2017, 25, 14173–14181. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Lyubomirskiy, M.; Koch, F.; Abrashitova, K.; Bessonov, V.; Kokareva, N.; Petrov, A.; Seiboth, F.; Wittwer, F.; Kahnt, M.; Seyrich, M.; et al. Ptychographic characterisation of polymer compound refractive lenses manufactured by additive technology. Opt. Express 2019, 27, 8639–8650. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Sanli, U.T.; Rodgers, G.; Zdora, M.C.; Qi, P.; Garrevoet, J.; Falch, K.V.; Müller, B.; David, C.; Vila-Comamala, J. Apochromatic X-ray focusing. Light Sci. Appl. 2023, 12, 107. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Kohn, V.; Snigireva, I.; Snigirev, A. Diffraction theory of imaging with X-ray compound refractive lens. Opt. Commun. 2003, 216, 247–260. [Google Scholar] [CrossRef] [Scilit]
  17. Materials v2—bmf3d.com. Available online: https://bmf3d.com/micro-3d-printing-materials/ (accessed on 8 December 2025).
  18. Gelorme, J.; Cox, R.; Gutierrez, S. Photoresist Composition and Printed Circuit Boards and Packages Made Therewith. U.S. Patent 4,882,245, 21 November 1989. [Google Scholar]
  19. Qiao, Z.; Shi, X.; Wojcik, M.J.; Rebuffi, L.; Assoufid, L. Single-Shot X-Ray Phase-Contrast and Dark-Field Imaging Based on Coded Binary Phase Mask. Appl. Phys. Lett. 2021, 119, 011105. [Google Scholar] [CrossRef] [Scilit]
  20. Zdora, M.C. State of the art of X-ray speckle-based phase-contrast and dark-field imaging. J. Imaging 2018, 4, 60. [Google Scholar] [CrossRef] [Scilit]
  21. Qiao, Z.; Shi, X.; Celestre, R.; Assoufid, L. Wavelet-transform-based speckle vector tracking method for X-ray phase imaging. Opt. Express 2020, 28, 33053–33067. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.