Skip to Content
AgricultureAgriculture
  • Article
  • Open Access

25 December 2025

10 Pages

Effect of Ecotechnological Chilling Parameters on Carcass Temperature and Mass Loss of Broiler Carcasses

,
,
and
1
Pivka Perutninarstvo d.d., Kal 1, 6257 Pivka, Slovenia
2
Faculty of Economics and Informatics, University of Novo Mesto, Na Loko 2, 8000 Novo Mesto, Slovenia
3
Faculty of Business and Management Sciences, University of Novo Mesto, Na Loko 2, 8000 Novo Mesto, Slovenia
4
Landscape Governance College Grm Novo Mesto, Ljubljanska Cesta 28, 8000 Novo Mesto, Slovenia

Abstract

This study comparatively evaluated the performance of three industrial broiler carcass chilling methods—air chilling, combination chilling (air and water spraying), and the Thor Ice ice-slurry system—under commercial processing conditions. A total of 90 Ross 308 carcasses were analyzed (30 per method, in three repetitions). Air chilling and Thor Ice chilling were conducted for 1 h 45 min at 4000 birds/h, whereas combination chilling lasted 3 h at 7200 birds/h. For each carcass, initial and final temperature and weight were recorded to determine chilling loss. Significant differences were observed among the methods (p < 0.05). Combination chilling achieved the lowest final temperature (1.4 °C), while Thor Ice chilling resulted in the smallest chilling loss (−0.47%). The analysis of energy consumption revealed that air chilling had the highest electrical energy use (15,491.6 kWh/h), whereas the Thor Ice system had a lower energy demand (13,511.2 kWh/h). Combination chilling exhibited the highest water consumption (413.7 m3), reflecting the use of water spraying. Based on these findings, combination chilling was the most effective in reducing carcass temperature, while the Thor Ice system provided a technologically efficient alternative with minimal mass loss and reduced energy demand.

1. Introduction

The global poultry industry is one of the fastest-growing sectors of animal-source food production, driven by rising demand for affordable, high-quality protein and efficient production systems. As processing volumes continue to rise, optimizing technological steps that influence food safety, product quality, and resource efficiency has become a central challenge for sustainable poultry production. Among all processing stages, carcass chilling represents a critical control point due to its direct impact on microbiological stability, physicochemical properties, yield, and operational energy use [1,2,3,4]. Warm post-mortem broiler carcasses provide favorable conditions for the proliferation of Salmonella spp., Campylobacter jejuni, and Listeria monocytogenes, making rapid reduction in internal temperature below 4 °C essential for ensuring product safety and extending shelf-life [1,5].
Two industrially dominant chilling technologies, air chilling and water immersion chilling—offer different thermal and quality outcomes. Air chilling, widely used in Europe, prevents excessive water uptake and generally supports improved sensory attributes, however, it is characterized by slower heat removal and higher energy demand due to less efficient convective transfer [6,7]. In contrast, immersion chilling in cold water or an ice slurry provides rapid, uniform cooling but often results in moisture absorption, increased cross-contamination risk, and yield variation during further processing [6]. These limitations have spurred the development of hybrid systems that combine the advantages of both methods.
Combination chilling, which alternates forced-air cooling with intermittent water spraying, enhances convective heat transfer while limiting carcass dehydration [3]. This method has been adopted in high-capacity plants because it offers a more balanced compromise among chilling speed, product quality, and energy use. Parallel to this development, ice-slurry technologies such as the Thor Ice system have emerged as promising innovations. By using a subzero ice-water suspension, these systems achieve highly efficient conductive heat transfer, enabling faster cooling and reduced moisture loss [8,9]. Recent studies report that subzero saline or slurry chilling can increase chilling efficiency, improve tenderness, and reduce bacterial loads compared with conventional methods [8,10].
The shift toward more sustainable agriculture has further highlighted the relevance of chilling technologies for energy efficiency, water consumption, and circular-economy strategies. Broiler production already faces pressures to reduce environmental impacts in feed use, energy consumption, hygiene management, and overall resource efficiency [11,12,13,14,15,16,17,18,19,20,21,22]. Since chilling systems represent a major contributor to total processing energy, the choice of method can significantly influence the environmental and economic performance of processing facilities. Studies emphasize the need for an integrative sustainability assessment that considers microbiological outcomes, energy demands, water use, and product quality [23,24,25,26].
Despite numerous investigations into individual chilling systems, comparative studies conducted under real industrial conditions remain scarce, particularly in the European context. Moreover, only a few studies simultaneously evaluate final carcass temperature, chilling loss, process stability, and operational constraints, although these represent key parameters for industrial decision-making [7,13,15]. This gap limits processors’ ability to adopt evidence-based strategies that align with sustainability and production efficiency goals.
Accordingly, the objective of this study was to comparatively evaluate three industrial broiler carcass chilling methods—(i) air chilling, (ii) combination chilling (air and water spraying), and (iii) the Thor Ice ice-slurry system—based on performance under commercial operating conditions. The study focused on quantifying their effects on:
  • Final carcass temperature as an indicator of heat-transfer efficiency;
  • Chilling loss (mass variation) as a measure of economic yield;
  • Temperature and weight stability as indicators of process consistency;
  • Energy and sustainability-related implications, interpreted within the framework of modern poultry processing.
By integrating technological, economic, and sustainability considerations, this study aims to contribute to a scientifically grounded evaluation of emerging chilling technologies and to support optimization of processing parameters in large-scale broiler production.

2. Materials and Methods

2.1. Experimental Material

Experimental material of Ross 308 broilers was used for this study, reared under standard commercial production conditions. The broilers were 42 days old at slaughter, with an average body weight of approximately 1.9–2.02 (±0.2) kg. After slaughter, the carcasses were bled, defeathered, and eviscerated in accordance with EU Regulation (EC) No. 853/2004 [27]. The experimental trial was conducted in June 2025.
Chilling methods for the study, broiler carcasses were randomly divided into three groups based on the chilling method used:
  • Thor Ice chilling (ice-slurry medium): Chilling with an ice-water slurry (medium temperature approx. 0 °C); chilling time 1 h 45 min; line capacity 4000 birds/h;
  • Air chilling: Chilling in a tunnel with circulating cold air (0–2 °C); chilling time 1 h 45 min; same line speed (4000 birds/h);
  • Combination chilling (air and water spraying): Combination of air flow and periodic cold-water spraying; total chilling time 3 h; line capacity 7200 birds/h.
For each method, 10 carcasses were analyzed in three independent repetitions (n = 30 per method; total n = 90 samples). Before chilling, each carcass was weighed, and its initial internal breast temperature (°C) was measured using a calibrated digital thermometer. Chilling was carried out under the aforementioned industrial conditions. After chilling, the final carcass temperature and weight were recorded. Temperature measurements were performed with a calibrated digital thermometer (±0.1 °C), and weights were measured with a precision scale (±1 g).

2.2. Experimental Design

Table 1 summarizes the experimental design and operational conditions used to evaluate the three chilling systems.
Table 1. Summary of consumption of water and electrical energy across chilling systems.
These parameters, including total chilling time, line capacity, chilling temperature, and the dominant heat-transfer mechanism, are integral to accurately describing the technological context in which the study was conducted. Such information is essential for ensuring reproducibility and for allowing meaningful comparison with previously published industrial chilling studies.
Because each chilling system operates under different technological constraints in real industrial settings, the parameters presented in Table 1, reflect standard commercial practice rather than controlled laboratory conditions. These operational differences were therefore incorporated into the study’s methodological framework and subsequently considered in the interpretation of the results. All measurements of carcass temperature and weight were performed immediately before and after chilling, as described in the subsequent subsections.

2.3. Chilling Yield Calculation

The yield loss (%) for each sample was calculated using the following equation:
C h i l l i n g   y i e l d   ( % ) = ( F i n a l   W e i g h t / I n i t i a l   W e i g h t ) · 100
The yield-based expression used in this study is a commonly applied industrial metric for quantifying carcass mass retention after chilling. Within this framework, values below 100% indicate net mass loss due to evaporation or drip loss, whereas values above 100% reflect slight water uptake.
Although the conventional scientific approach typically expresses chilling loss as the percentage reduction in weight relative to the initial carcass mass, yield-based calculations have also been used in previous studies evaluating chilling technologies under real industrial conditions. Notably, Kang et al. [10] employed a comparable yield formulation when assessing subzero saline chilling of turkey carcasses, demonstrating that this methodological choice is consistent with approaches used in processing-oriented research.
By applying this industry-aligned metric, the present study ensures methodological continuity with established practices in poultry processing plants and facilitates direct interpretation and applicability of results for industrial stakeholders.

2.4. Statistical Analysis

Data were analyzed using the Statistical Package for the Social Sciences (SPSS, v. 30). For each chilling method, means and standard deviations (SD) were calculated. The one-way analysis of variance (ANOVA) was used to test for statistically significant differences among methods, with a significance level of p < 0.05.
Tukey’s HSD test was applied for post hoc comparisons between group pairs to identify statistically significant differences. Results were interpreted using p-values, 95% confidence intervals (CI), and mean differences (meandiff).
For each chilling system, tunnel chilling time, line capacity, and average initial carcass weight were also recorded and integrated into the interpretation of results due to their direct effect on heat transfer and mass variation.
Table 2 summarizes the experimental design comparing three industrial broiler carcass chilling methods. It details the number of samples, replications, chilling duration, line capacity, and key thermal parameters. The table emphasizes the different heat transfer mechanisms—conduction, convection, and mixed modes—that define Thor Ice, air, and combination chilling systems, respectively.
Table 2. Summary of experimental design.

3. Results

Although the results showed statistically significant differences among the chilling methods, these differences must be interpreted within the context of the non-uniform industrial conditions (chilling time, line capacity, and heat-transfer environment). As such, the findings reflect process-specific performance rather than demonstrating that one method is inherently superior to the other. The study of variance (ANOVA) showed a very high level of significance (p < 0.001) for the temperature parameter (Table 3) and p = 0.0012 for chilling loss (Table 5), confirming that the applied chilling methods have a substantial effect on the quality of the final product.
Table 3. Temperature (°C) and weight (kg) of eviscerated chicken carcasses before and after chilling using different cooling methods.
The final carcass temperature after chilling was lowest in the combination chilling method (air and water spraying), with mean values around 1.41 °C and a low standard deviation (SD = 0.55 °C). This indicates high heat transfer efficiency during the longer chilling time (3 h) and higher air throughput (7200 birds/h). Air chilling achieved the highest mean final temperature (5.82 °C) and the greatest variability (SD = 2.42 °C). The Thor Ice system, based on immersion in an ice slurry, ensured stable cooling consistency, achieving an average temperature of 4.09 °C with SD = 1.52 °C, while minimizing chilling loss.
The Tukey HSD test (Table 4) further confirmed that the differences between the combination chilling and the other two methods were statistically significant (p < 0.05). In contrast, the differences between Thor Ice and air chilling were not statistically significant for all parameters. This indicates that combination chilling allows for more intense heat transfer and greater temperature stability.
Table 4. Tukey HSD—temperature of eviscerated chicken carcasses.
For chilling loss, the differences between methods were also statistically confirmed (p = 0.0012). Combination chilling showed minimal mass change (−0.07%) but also the highest variability (SD = 0.81%), likely due to water absorption during spraying and the longer exposure time (Table 5). Both Thor Ice and air chilling exhibited negative chilling losses (−0.47% and −0.62%), with SDs of 0.35% and 0.51%, respectively, indicating smaller weight reductions and, consequently, higher economic efficiency. The Thor Ice system provided stable post-chill mass values, confirming the efficiency of ice as a heat transfer medium (Table 5).
Table 5. Chilling loss of eviscerated chicken carcasses (%).
Table 5 compares chilling loss across the three methods. The results show that combination chilling had the smallest weight reduction (−0.07%), whereas air chilling had the greatest loss (−0.62%). The Thor Ice system had a minimal loss (−0.47%), demonstrating better mass retention and consistent process performance (p = 0.0012).
The results of the Tukey test for the chilling loss parameter further support the one-way ANOVA findings and identify which chilling methods differ significantly. As shown in Table 6, both combination chilling and Thor Ice showed statistically significant differences compared with air chilling (p = 0.0222 and p = 0.0012, respectively). Combination chilling resulted in a notably lower chilling loss (p = 0.6008). In contrast, the difference between Thor Ice and air chilling was not statistically significant, indicating partial overlap in their effects. The 95% confidence intervals additionally confirm the robustness of the estimated mean differences.
Table 6. Tukey HSD—chilling loss of eviscerated chicken carcasses.
From the perspectives of production economics and meat quality, combination chilling proved most effective in achieving low final temperatures. However, it required a longer processing time and higher energy input. The Thor Ice system represents a balanced compromise between efficiency, speed, and cooling uniformity, while air chilling remains the simplest but least thermally efficient method. Overall, the results indicate that optimization of chilling time, medium temperature, and line speed is crucial for minimizing mass losses and achieving a microbiologically safe product without unnecessary yield reductions.

4. Discussion

The results of this analysis demonstrate that different chilling methods have a significant impact on temperature and carcass mass-loss parameters, consistent with previous studies [1,2]. Statistically significant differences (p < 0.001) in final temperatures were observed among Thor Ice, air chilling, and combination chilling. This confirms that the efficiency of heat transfer primarily depends on the mode of contact between the chilling medium and the carcass surface, as well as on process duration [3]. However, these differences must be interpreted within the constraints of the non-standardized industrial conditions under which each technology operates.
Combination chilling, which integrates air flow and water spraying, achieved the lowest final temperatures (1.4 °C) and the least variability, likely due to the prolonged chilling time (3 h) and enhanced convective heat transfer enabled by the thin water film on the carcass surface [1,2]. According to Huezo et al. [5], the combined method is optimal for reducing the risk of microbial growth while maintaining meat sensory quality. However, longer chilling time and greater energy consumption reduce production efficiency.
Air chilling produced the highest final temperatures (mean 5.8 °C) and the greatest standard deviations, consistent with Rodrigues et al. [15], who reported that air chilling is slower due to its limited thermal conductivity and dependence on airflow velocity. Conversely, the Thor Ice system, which uses an ice-slurry medium, achieved rapid temperature reduction with minimal weight loss. The observed weight loss was comparable to that of air chilling and lower than that associated with combination chilling, as also reported by Kawamura et al. [8] and Kang et al. [10]. The ice medium provides high thermal conductivity while limiting surface dehydration, resulting in the lowest chilling loss among the examined methods.
Tukey’s HSD test confirmed statistically significant differences (p < 0.05) between combination chilling and the other two methods, aligning with prior research on systems involving partial water contact. Under comparable conditions, Huezo et al. [5] reported that air-chilled carcasses lost up to 2.5% of their pre-chill weight, whereas water-immersion chilling caused weight gains of up to 9.3%, with values ranging from 2.2–3.5% to 3.4–14.7%. Similarly, Young and Smith [18] found that water-immersion chilled carcasses gained 4–12% of their pre-chill weight, while Mielnik et al. [19] reported that air-chilled carcasses lost up to 3% compared with immersion-chilled carcasses.
The differences between Thor Ice and air chilling were not always statistically significant, suggesting relatively similar efficiency levels, however, Thor Ice exhibited greater consistency and lower variability. For chilling loss (p = 0.0012), the differences among methods were also significant. Combination chilling occasionally resulted in a positive chilling loss (a slight weight increase) due to water adsorption on the carcass surface. Thor Ice and air chilling, in contrast, demonstrated negative chilling loss (~0.5%), confirming minimal weight reduction and better economic efficiency [8,10,18]. The effectiveness of ice-based chilling stems from direct thermal contact, enabling faster, more uniform cooling without increasing the meat’s water content.
From a microbiological safety perspective, achieving lower final temperatures more quickly may offer favorable conditions for reducing microbial risk, although microbiological parameters were not assessed in this study. However, it is important to consider possible effects on meat texture and color, which may be slightly altered by surface moisture [20]. The use of energy-efficient and water-saving systems, such as ice-slurry chilling (Thor Ice), represents a more environmentally sustainable alternative to traditional chilling methods in the poultry industry.
The overall findings emphasize that selecting an appropriate chilling system in poultry processing should consider technological efficiency, product quality, and sustainability. While combination chilling yielded the most effective temperature reduction, the Thor Ice slurry-ice system showed significant promise as a water- and energy-efficient option [1]. Recent research supports this, such as the slurry-ice device IceGun, which considerably lowered Campylobacter levels on broiler carcasses and sped up chilling without affecting product quality [20]. Additionally, studies on sub-zero saline and hybrid chilling systems highlight improvements in efficiency and sustainability through advanced heat-transfer techniques and resource-saving methods [3]. Together, these results highlight the importance of optimizing processes to reduce resource use, enhance energy efficiency, and maintain product quality—aligning with the aims of creating sustainable and economically viable food production systems [4,5,6,7,25,26].

5. Limitations Section

A central limitation of this study is that the three chilling systems were evaluated under their respective industrial operating conditions, which inherently differ in chilling duration, line capacity, and dominant heat-transfer mechanisms. While these parameters reflect authentic commercial practice and therefore strengthen the practical relevance of the findings, they also limit the ability to isolate the pure technological effect of each chilling method. Consequently, the results should be interpreted as representative of real production environments rather than controlled laboratory comparisons.
Future research should evaluate these chilling technologies under harmonized experimental conditions—including equal residence time, standardized line speed, and the same target final temperature—to enable a more controlled assessment of their relative technological efficiency.
A further limitation relates to the calculation of chilling yield. The present study employed a yield-based formula (Final Weight/Initial Weight × 100), which is widely used in industrial poultry processing and has been applied in previous published research. However, this approach differs from the conventional scientific method for expressing chilling loss, which reports the percentage decrease in mass relative to the initial weight. Although both metrics are valid and informative, comparisons with studies using the traditional loss-based formula should be interpreted with caution due to the methodological differences.

6. Conclusions

The results of this study demonstrated that the method of carcass chilling significantly affects both temperature reduction and weight changes in broiler chickens after processing. Among the evaluated systems, combination chilling proved most effective for achieving uniform, rapid cooling, thereby improving meat quality and product stability. Air chilling resulted in greater moisture loss due to surface evaporation, whereas the Thor Ice ice-slurry system maintained a balanced relationship among cooling efficiency, mass retention, and product quality.
Statistical analysis confirmed that the chilling methods differed significantly in terms of temperature and weight-related parameters. The findings indicate that the combination of cooling mechanisms (airflow and water spraying or ice slurry) offers better process control and lower variability in results.
From an industrial perspective, the results have broader implications for process optimization, sustainability, and product yield.
Combination chilling is particularly suitable for processing environments where achieving very low carcass temperatures is a priority, while the Thor Ice system may be preferred where water use, weight retention, and energy balance are key considerations.
Air chilling remains operationally simple but may require further optimization of airflow, humidity, and chilling duration to minimize yield loss and variability.
Despite their relevance, the findings must be interpreted within the study’s methodological limitations. The study was conducted on a single broiler genotype (Ross 308) within a single industrial plant under summer conditions, which may limit generalizability to other production systems or seasons. Additionally, the study did not include microbiological, sensory, or physicochemical analyses.
Future research should incorporate harmonized chilling conditions across methods (equal line speeds, exposure times, and temperatures) to isolate technological efficiency more precisely. Additional studies should evaluate: microbial safety outcomes, sensory and physicochemical quality, environmental impacts, performance across seasons, and different broiler breeds.
In conclusion, this study provides relevant insights into the performance of modern chilling technologies under real industrial conditions. It highlights the potential of combination and ice-slurry systems to rapidly reduce temperature while maintaining carcass yield, supporting the development of more sustainable, data-driven strategies in poultry processing.

Author Contributions

Conceptualization, D.B.-Š. and A.Š.; methodology, D.B.-Š.; software, D.B.-Š.; validation, D.B.-Š., A.Š., S.G. and L.-M.C.-J.; formal analysis, D.B.-Š.; investigation, D.B.-Š.; resources, D.B.-Š.; data curation, D.B.-Š.; writing—original draft preparation, D.B.-Š. and A.Š.; writing—review and editing, D.B.-Š., A.Š., S.G. and L.-M.C.-J.; visualization, S.G. and L.-M.C.-J.; supervision, D.B.-Š., A.Š. and S.G.; project administration, A.Š.; funding acquisition, D.B.-Š., A.Š., S.G. and L.-M.C.-J. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable. A formal ethical review was not required, as all animal-related procedures were carried out as part of routine industrial operations in an authorized poultry processing plant. Trained personnel and the supervising veterinarian ensured humane stunning and slaughter in accordance with legal requirements. The research phase began only after carcass evisceration (post mortem) and involved the measurement of technological chilling parameters exclusively. All procedures complied with Council Regulation (EC) No. 1099/2009 [28] on the protection of animals at the time of killing.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

During the preparation of this manuscript/study, the author(s) used Grammarly, version information for language editing, ChatGPT 5.1, and GrammarlyPRO v 1.2.212.1789 were used for copy editing, and SPSS v. 30 for the results calculations. The authors have reviewed and edited the output and take full responsibility for the content of this publication. The authors would like to express their sincere gratitude to Pivka perutninarstvo d. d. for providing the facilities and technical support necessary for conducting the experimental part of this study.

Conflicts of Interest

Author Diana Bilić-Šobot was employed by the company Pivka Perutninarstvo d.d. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest

References

  1. Belk, A.D.; Duarte, T.; Quinn, C.; Coil, D.A.; Belk, K.E.; Eisen, J.A.; Quinn, J.C.; Martin, J.N.; Yang, X.; Metcalf, J.L. Air versus water chilling of chicken: A pilot study of quality, shelf-life, microbial ecology, and economics. Systems 2021, 6, e00912-20. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Ricke, S.C. Achieving Sustainable Production of Poultry Meat. In Safety, Quality and Sustainability; Burleigh Dodds Science Publishing: Cambridge, UK, 2017; Volume 1. [Google Scholar]
  3. Li, Z.; Huang, H.; Wang, P.; Xing, T.; Xu, X. Water-spraying forced ventilation during holding improves the water holding capacity, impedance, and microstructure of breast meat from summer-transported broiler chickens. Poult. Sci. 2019, 99, 1744–1749. [Google Scholar]
  4. Munther, D.; Sun, X.; Xiao, Y.; Tang, S.; Shimozako, H.; Wu, J.; Smith, B.A.; Fazil, A. Modeling cross-contamination during poultry processing: Dynamics in the chiller tank. Food Control 2016, 59, 271–281. [Google Scholar] [CrossRef] [Scilit]
  5. Huezo, R.; Northcutt, J.K.; Smith, D.P.; Fletcher, D.L.; Ingram, K.D. Effect of dry air or immersion chilling on recovery of bacteria from broiler carcasses. J. Food Prot. 2007, 70, 1829–1834. [Google Scholar] [CrossRef] [Scilit]
  6. James, C.; Vincent, C.; de Andrade Lima, T.I.; James, S.J. The primary chilling of poultry carcasses: A review. Int. J. Refrig. 2006, 29, 847–862. [Google Scholar] [CrossRef] [Scilit]
  7. Nauman, K.; Ali, S.; Mustafa, A.J.; Mehmood, S. Comparison of the effects of air and water immersion chilling on processing and sensory attributes of broiler carcasses. Arch. Für Leb. 2020, 71, 129–133. [Google Scholar]
  8. Kawamura, K.; Ma, D.; Pereira, A.; Ahn, D.U.; Kim, D.M.; Kang, I. Subzero saline chilling with or without prechilling in icy water improved chilling efficiency and meat tenderness of broiler carcasses. Poult. Sci. 2023, 102, 103070. [Google Scholar] [CrossRef] [Scilit]
  9. Veerkamp, C.H. Chilling of poultry and poultry products. In Chilled Foods: The State of the Art; Gormley, T.R., Ed.; Elsevier Applied Science: New York, NY, USA, 1990; Volume 1, pp. 147–158. [Google Scholar]
  10. Kang, H.C.; Lee, H.C.; Park, S.H. Research note: Subzero saline chilling improved chilling efficiency and bacterial reduction of turkey carcasses. Poult. Sci. 2021, 100, 101458. [Google Scholar] [CrossRef] [Scilit]
  11. Bilić-Šobot, D. Current trends with enzyme applications in industrial broiler production. Asian J. Dairy Food Res. 2024, 43, 71–78. [Google Scholar]
  12. Bilić-Šobot, D. Essential points of effective mechanical cleaning in the poultry meat industry. In Globalisation Challenges and the Social-Economic Environment of the EU: Book of Proceedings; University of Novo Mesto, Faculty of Business and Management Sciences: Novo mesto, Slovenia, 2025; p. 17. ISBN 978-961-6770-89-7. [Google Scholar]
  13. Rašeta, M.; Branković-Lazić, I.; Mrdović, B.; Beckei, Z. Determination of Weight Loss and Temperature of Broiler Carcasses During Air Cooling with Intermittent Water Spraying—Case Study; Institute of Meat Hygiene and Technology: Belgrade, Serbia, 2010. [Google Scholar]
  14. Sunoh, C.; Susta, L.; Barbut, S. Effects of broiler chilling methods on the occurrence of pale, soft, exudative (PSE) meat and comparison of detection methods. Poult. Sci. 2023, 102, 102907. [Google Scholar] [CrossRef] [Scilit]
  15. Rodrigues, L.G.G.; Carciofi, B.A.M.; Laurindo, J.B. Poultry carcasses chilled by forced air, water immersion and combination of forced air and water immersion. J. Food Process Eng. 2015, 37, 550–559. [Google Scholar] [CrossRef] [Scilit]
  16. Gričar, S.; Šugar, V. Sustainable consumption using the example of food processing in a restaurant. Sustainability 2021, 13, 13868. [Google Scholar] [CrossRef] [Scilit]
  17. Huezo, R.; Northcutt, J.K.; Smith, D.P.; Fletcher, D.L. Effect of chilling method and deboning time on broiler breast fillet quality. J. Appl. Poult. Res. 2007, 16, 537–545. [Google Scholar] [CrossRef] [Scilit]
  18. Young, L.L.; Smith, D.P. Moisture retention by water and air-chilled chicken broilers during processing and cut-up operations. Poult. Sci. 2004, 83, 119–122. [Google Scholar] [CrossRef] [Scilit]
  19. Mielnik, M.B.; Dainty, R.H.; Lundby, F.; Mielnik, J. The effect of evaporative air chilling and storage temperature on quality and shelf life of fresh chicken carcasses. Poult. Sci. 1999, 78, 106–111. [Google Scholar] [CrossRef] [Scilit]
  20. Leone, C.; Xu, X.; Mishra, A.; Thippareddi, H.; Singh, M. Interventions to reduce Salmonella and Campylobacter during chilling and post-chilling stages of poultry processing: A systematic review and meta-analysis. Poult. Sci. 2024, 103, 103492. [Google Scholar] [CrossRef] [Scilit]
  21. Beal, C.M.; Robinson, D.M.; Smith, J.; Van Doren, L.G.; Tabler, G.T.; Rochell, S.J.; Lei, X. Economic and environmental assessment of U.S. broiler production: Opportunities to improve sustainability. Poult. Sci. 2023, 102, 102887. [Google Scholar] [CrossRef] [Scilit]
  22. John, E.P.; Mishra, U. Sustainable Broiler Chicken Meat Production: A Three-Layer Model for Emissions Reduction and Traceability. J. Clean. Prod. 2024, 476, 143731. [Google Scholar] [CrossRef] [Scilit]
  23. Sundrum, A. Public Welfare-Oriented Production of Food: Substantially New Impulses for a Sustainable Agro-Food Sector; Springer Nature: Cham, Switzerland, 2024. [Google Scholar]
  24. Vlaicu, P.A.; Untea, A.E.; Oancea, A.G. Sustainable Poultry Feeding Strategies for Achieving Zero Hunger and Enhancing Food Quality. Agriculture 2024, 14, 1811. [Google Scholar] [CrossRef] [Scilit]
  25. Abbasi, I.A.; Shamim, A.; Shad, M.K.; Ashari, H.; Yusuf, I. Circular Economy-Based Integrated Farming System for Indigenous Chicken: Fostering Food Security and Sustainability. J. Clean. Prod. 2024, 436, 140368. [Google Scholar] [CrossRef] [Scilit]
  26. Adaszyńska-Skwirzyńska, M.; Konieczka, P.; Bucław, M.; Majewska, D.; Pietruszka, A.; Zych, S.; Szczerbińska, D. Analysis of the Production and Economic Indicators of Broiler Chicken Rearing in 2020–2023: A Case Study of a Polish Farm. Agriculture 2025, 15, 139. [Google Scholar] [CrossRef] [Scilit]
  27. European Union. Regulation (EC) No. 853/2004 of the European Parliament and of the Council of 29 April 2004 laying down specific hygiene rules for food of animal origin. Off. J. Eur. Union 2004, L 139, 55–205. [Google Scholar]
  28. European Union. Council Regulation (EC) No. 1099/2009 of 24 September 2009 on the protection of animals at the time of killing. Off. J. Eur. Union 2009, L 303, 1–30. [Google Scholar]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.