Abstract
This paper presents the prototype validation of an accelerated gradient observer (AGO)-assisted continuous predictive control (CPC)-based model-free control framework for a fuel-cell/supercapacitor/battery (FC/SC/battery) hybrid power source in electric-vehicle applications. The AGO, based on second-order gradient-descent dynamics, estimates lumped nonlinearities, parameter variations, unmodeled dynamics, and disturbances through ultra-local models. These estimates are integrated into three outer energy-management loops and three inner current-control loops to regulate the DC bus and coordinate multi-time-scale power sharing among the fast supercapacitor, intermediate battery, and slow fuel cell while respecting source constraints. Lyapunov analyses establish nominal tracking convergence and AGO stability under stated assumptions. Simulation comparisons with an extended-state observer (ESO), sliding-mode observer (SMO), and high-order disturbance observer (HODO) show that the AGO provides smooth, overshoot-free estimation under noise-free conditions, although the ESO yields lower ITSE and IAE values. Under measurement noise, the AGO reduces normalized RMSE, error standard deviation, and maximum absolute error by 80%, 95%, and 79%, respectively, relative to the ESO. Experimental tests on a 25 kHz prototype using a real 2.5 kW PEMFC in motoring mode and an FC emulator during regenerative braking confirm stable 96 V DC-bus regulation, approximately 1.6 ms recovery in the SC-only CPL test, coordinated power sharing, energy recovery, and source protection.