Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline

Search Results (228)

Search Parameters:
Keywords = screen-printed gold electrode

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 1334 KB  
Article
Development of a Paper-Based Electrochemical Immunosensor for Cardiac Troponin I Determination Using Gold Nanoparticle-Modified Screen-Printed Electrodes
by Mayra Asevedo Campos de Resende, Ana Elisa Ferreira Oliveira, Thaís Cristina de Oliveira Cândido, Daniela Nunes da Silva, Scarlat Ohanna Dávila da Trindade, Lucas Franco Ferreira and Arnaldo César Pereira
Chemosensors 2025, 13(11), 383; https://doi.org/10.3390/chemosensors13110383 - 31 Oct 2025
Viewed by 604
Abstract
Acute Myocardial Infarction (AMI) is a critical cardiac condition that poses a substantial threat to myocardial function. Expedient diagnosis of AMI is paramount and relies on serological assays for rapid and accurate quantification of relevant biomarkers. Electrochemical sensors have emerged as promising candidates [...] Read more.
Acute Myocardial Infarction (AMI) is a critical cardiac condition that poses a substantial threat to myocardial function. Expedient diagnosis of AMI is paramount and relies on serological assays for rapid and accurate quantification of relevant biomarkers. Electrochemical sensors have emerged as promising candidates for this application, owing to their accessibility, operational simplicity, and high specificity. In this study, we developed a paper-based electrochemical immunosensor to detect cardiac troponin I in serum and saliva specimens. The electrode was fabricated using screen-printing technology with photographic paper as the substrate, employing graphite-based ink, nail polish, and acetone as the solvent. A quasi-reference electrode was constructed using silver powder-based ink, nail polish, and acetone. The immunosensor was prepared by modifying the working electrode with gold nanoparticles (AuNP) functionalized with cardiac troponin I antibodies (anti-cTnI) and bovine serum albumin (BSA). This modified electrode was subsequently used to detect the troponin I antigen. The analyses were performed in 0.1 mol L−1 phosphate buffer medium, pH 7.00, in the presence of 5.0 mmol L−1 of the potassium ferrocyanide probe. The immunosensor exhibited a sensitivity of 0.006 µA/fg mL−1, a limit of detection of 9.83 fg mL−1, and a limit of quantification of 32.79 fg mL−1. Specificity studies conducted in the presence of other macromolecules demonstrated minimal interference, with relative standard deviations (RSD) below 5.00%, indicating a specific interaction with troponin I. Furthermore, the immunosensor demonstrated excellent reproducibility and stability. Upon application to serum and saliva samples, the immunosensor presented recoveries of approximately 99–105%, suggesting its potential applicability in clinical analyses. Full article
Show Figures

Graphical abstract

12 pages, 2177 KB  
Article
A Sweat Cortisol Sensor Based on Gold-Modified Molecularly Imprinted Polymer
by Ziyu Liu, Guangzhong Xie, Jing Li, Hong Yuan and Yuanjie Su
Nanomaterials 2025, 15(21), 1654; https://doi.org/10.3390/nano15211654 - 30 Oct 2025
Viewed by 538
Abstract
Approximately 3.8% of the global population suffers from depressive disorders, posing a substantial public health challenge exacerbated by the COVID-19 pandemic due to widespread unemployment and prolonged social isolation. The difficulty in objectively quantifying psychological states underscores the need for effective stress assessment [...] Read more.
Approximately 3.8% of the global population suffers from depressive disorders, posing a substantial public health challenge exacerbated by the COVID-19 pandemic due to widespread unemployment and prolonged social isolation. The difficulty in objectively quantifying psychological states underscores the need for effective stress assessment methods. Herein, we developed a portable electrochemical cortisol sensor (PECS) for accurate mental stress assessment. The PECS consists of a screen-printed carbon electrode decorated with gold nanoparticles and a molecularly imprinted polymer (MIP) synthesized via electropolymerization. The as-prepared PECS demonstrates a wide and linear detection range from 1 fM to 1 μM, an ultra-low detection limit of 0.4112 fM and a high sensitivity of 15.518 nA∙lg(nM−1)∙cm−2. This work provides new possibility of developing soft bioelectronics for non-invasive and real-time mental health monitoring. Full article
(This article belongs to the Special Issue Application of Nanoscale Smart Textiles in Wearable Sensors)
Show Figures

Figure 1

14 pages, 5797 KB  
Article
Investigation of Blade Printing Technique for Nano-Structuring Piezoelectric Polymer Ink in a Porous Anodic Aluminum Oxide
by Tsvetozar Tsanev and Mariya Aleksandrova
Polymers 2025, 17(21), 2839; https://doi.org/10.3390/polym17212839 - 24 Oct 2025
Viewed by 378
Abstract
In this work, we investigated the use of a piezoelectric flexible device for energy harvesting. The main goal of the study was to fill the nanostructured pores of anodic aluminum oxide (AAO) films with piezoelectric polymer (PVDF-TrFE) via a modified conventional screen printing [...] Read more.
In this work, we investigated the use of a piezoelectric flexible device for energy harvesting. The main goal of the study was to fill the nanostructured pores of anodic aluminum oxide (AAO) films with piezoelectric polymer (PVDF-TrFE) via a modified conventional screen printing technique using blade printing. In this way, it is possible to obtain a composite from nanostructured thin films of polymer nanorods that shows improved charge generation ability compared to other non-nanostructured composites or pure (non-composite) aluminum with similar dimensions. This behavior is due to the effect of the highly developed surface of the material used to fill in the AAO nanopore template and its ability to withstand the application of higher mechanical loads to the structured piezoelectric material during deformation. The contact blade print filling technique can produce nanostructured piezoelectric polymer films with precise geometric parameters in terms of thickness and nanorod diameters, at around 200 nm, and a length of 12 μm. At a low frequency of 17 Hz, the highest root-mean-square (RMS) voltage generated using the nanostructured AAO/PVDF-TrFE sample with aluminum electrodes was around 395 mV. At high frequencies above 1700 Hz, the highest RMS voltage generated using the nanostructured AAO/PVDF-TrFE sample with gold electrodes was around 680 mV. The RMS voltage generated using a uniform (non-nanostructured) layer of PVDF-TrFE was 15% lower across the whole frequency range. Full article
(This article belongs to the Special Issue Advanced Polymers for Harnessing Power and Energy)
Show Figures

Graphical abstract

13 pages, 1212 KB  
Article
Direct ECL Detection of Fentanyl Drug with Bare Screen-Printed Electrodes
by David Ibáñez, María Begoña González-García, David Hernández-Santos and Pablo Fanjul-Bolado
Biosensors 2025, 15(10), 697; https://doi.org/10.3390/bios15100697 - 15 Oct 2025
Viewed by 479
Abstract
Electrogenerated chemiluminescence (ECL) is a powerful analytical technique that combines the best features of both electrochemical and photoluminescence methods. In this work, we present a direct ECL-based method for the detection of fentanyl using unmodified screen-printed electrodes. The analysed system consists of tris(2,2′-bipyridyl)ruthenium(II) [...] Read more.
Electrogenerated chemiluminescence (ECL) is a powerful analytical technique that combines the best features of both electrochemical and photoluminescence methods. In this work, we present a direct ECL-based method for the detection of fentanyl using unmodified screen-printed electrodes. The analysed system consists of tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) as the luminophore and fentanyl as the co-reactant. A comprehensive optimization of the experimental parameters, such as buffer pH, luminophore concentration and working electrode material, was performed in order to maximize the ECL response. The optimal conditions are identified as PBS buffer pH 6, 2.5 × 10−3 M Ru(bpy)32+ and bare gold screen-printed electrodes. Under these conditions, the system exhibited a strong and reproducible ECL signal, with a linear response to fentanyl concentration from 1 × 10−7 to 1 × 10−5 M and a limit of detection of 6.7 × 10−8 M. Notably, the proposed method does not require electrode surface modification, sample pretreatment or complex instrumentation, offering a rapid, sensitive, and cost-effective alternative for fentanyl detection. Furthermore, the storage of bare SPEs at room temperature in a dry place ensures their stability over months or even years, overcoming the limitations offered by ECL systems based on modifications of the working electrode with different nanomaterials. These findings highlight the potential of the proposed ECL approach as a robust and sensitive tool for the detection of synthetic opioids. Its simplicity, portability, and analytical performance make it particularly attractive for forensic and clinical applications where rapid and accurate opioid screening is essential. Full article
(This article belongs to the Special Issue Recent Developments in Micro/Nano Sensors for Biomedical Applications)
Show Figures

Graphical abstract

16 pages, 2987 KB  
Article
Rapid and Sensitive Glucose Detection Using Recombinant Corn Mn Peroxidase and Advanced Voltammetric Methods
by Anahita Izadyar, Ezekiel McCain and Elizabeth E. Hood
Sensors 2025, 25(19), 5974; https://doi.org/10.3390/s25195974 - 26 Sep 2025
Viewed by 705
Abstract
We present a novel disposable electrochemical biosensor for highly sensitive and selective glucose detection, employing gold-modified screen-printed electrodes combined with square wave (SWV) and linear sweep voltammetry (LSV). The sensor integrates recombinant corn-derived manganese peroxidase with glucose oxidase, bovine serum albumin, and gold [...] Read more.
We present a novel disposable electrochemical biosensor for highly sensitive and selective glucose detection, employing gold-modified screen-printed electrodes combined with square wave (SWV) and linear sweep voltammetry (LSV). The sensor integrates recombinant corn-derived manganese peroxidase with glucose oxidase, bovine serum albumin, and gold nanoparticles to enhance stability and signal transduction. Glucose detection by LSV covered 0.001–6.5 mM (R2 = 0.9913; LOD = 0.50 µM), while SWV achieved a broader range of 0.0006–6.5 mM (R2 = 0.998; LOD = 0.29 µM). The sensor demonstrated excellent selectivity, showing minimal interference from common electroactive species including caffeine, aspartame, and ascorbic acid, and provided rapid responses, making it ideal for point-of-care and food monitoring applications. Full article
(This article belongs to the Section Chemical Sensors)
Show Figures

Figure 1

30 pages, 6580 KB  
Article
Advanced Nanomaterial-Based Electrochemical Biosensing of Loop-Mediated Isothermal Amplification Products
by Ana Kuprešanin, Marija Pavlović, Ljiljana Šašić Zorić, Milinko Perić, Stefan Jarić, Teodora Knežić, Ljiljana Janjušević, Zorica Novaković, Marko Radović, Mila Djisalov, Nikola Kanas, Jovana Paskaš and Zoran Pavlović
Biosensors 2025, 15(9), 584; https://doi.org/10.3390/bios15090584 - 5 Sep 2025
Viewed by 1178
Abstract
The rapid and sensitive detection of regulatory elements within transgenic constructs of genetically modified organisms (GMOs) is essential for effective monitoring and control of their distribution. In this study, we present several innovative electrochemical biosensing platforms for the detection of regulatory sequences in [...] Read more.
The rapid and sensitive detection of regulatory elements within transgenic constructs of genetically modified organisms (GMOs) is essential for effective monitoring and control of their distribution. In this study, we present several innovative electrochemical biosensing platforms for the detection of regulatory sequences in genetically modified (GM) plants, combining the loop-mediated isothermal amplification (LAMP) method with electrodes functionalized by two-dimensional (2D) nanomaterials. The sensor design exploits the high surface area and excellent conductivity of reduced graphene oxide, Ti3C2Tx, and molybdenum disulfide (MoS2) to enhance signal transduction. Furthermore, we used a “green synthesis” method for Ti3C2Tx preparation that eliminates the use of hazardous hydrofluoric acid (HF) and hydrochloric acid (HCl), providing a safer and more sustainable approach for nanomaterial production. Within this framework, the performance of various custom-fabricated electrodes, including laser-patterned gold leaf films, physical vapor deposition (PVD)-deposited gold electrodes, and screen-printed gold electrodes, is evaluated and compared with commercial screen-printed gold electrodes. Additionally, gold and carbon electrodes were electrochemically covered by gold nanoparticles (AuNPs), and their properties were compared. Several electrochemical methods were used during the DNA detection, and their importance and differences in excitation signal were highlighted. Electrochemical properties, sensitivity, selectivity, and reproducibility are characterized for each electrode type to assess the influence of fabrication methods and material composition on sensor performance. The developed biosensing systems exhibit high sensitivity, specificity, and rapid response, highlighting their potential as practical tools for on-site GMO screening and regulatory compliance monitoring. This work advances electrochemical nucleic acid detection by integrating environmentally-friendly nanomaterial synthesis with robust biosensing technology. Full article
(This article belongs to the Section Biosensor Materials)
Show Figures

Graphical abstract

16 pages, 2774 KB  
Article
Enzyme-Free Monitoring of Glucose Using Molecularly Imprinted Polymers and Gold Nanoparticles
by Ana Rita Aires Cardoso, Pedro Miguel Cândido Barquinha and Maria Goreti Ferreira Sales
Biosensors 2025, 15(8), 537; https://doi.org/10.3390/bios15080537 - 15 Aug 2025
Viewed by 694
Abstract
This work describes a non-enzymatic electrochemical glucose biosensor combining for the first time molecularly imprinted polymers (MIPs) for glucose concentration and gold nanoparticles (AuNPs) on screen-printed carbon electrodes (SPEs), where both MIPs and AuNPs were assembled in situ. Electrochemical impedance spectroscopy (EIS) was [...] Read more.
This work describes a non-enzymatic electrochemical glucose biosensor combining for the first time molecularly imprinted polymers (MIPs) for glucose concentration and gold nanoparticles (AuNPs) on screen-printed carbon electrodes (SPEs), where both MIPs and AuNPs were assembled in situ. Electrochemical impedance spectroscopy (EIS) was used to evaluate the analytical performance of the sensor, which has a linear range between 1.0 µM and 1.0 mM when standard solutions are prepared in buffer. Direct measurement of glucose was performed by chronoamperometry, measuring the oxidation current generated during direct glucose oxidation. The selectivity was tested against ascorbic acid and the results confirmed a selective discrimination of the electrode for glucose. Overall, the work presented here represents a promising tool for tracking glucose levels in serum. The use of glucose MIP on the electrode surface allows the concentration of glucose, resulting in lower detection limits, and the use of AuNPs reduces the potential required for the oxidation of glucose, which increases selectivity. In addition, this possible combination of two analytical measurements following different theoretical concepts can contribute to the accuracy of the analytical measurements. This combination can also be extended to other biomolecules that can be electrochemically oxidised at lower potentials. Full article
Show Figures

Figure 1

18 pages, 3248 KB  
Article
Electrochemical Nanostructured Aptasensor for Direct Detection of Glycated Hemoglobin
by Luminita Fritea, Cosmin-Mihai Cotrut, Iulian Antoniac, Simona Daniela Cavalu, Luciana Dobjanschi, Angela Antonescu, Liviu Moldovan, Maria Domuta and Florin Banica
Int. J. Mol. Sci. 2025, 26(15), 7140; https://doi.org/10.3390/ijms26157140 - 24 Jul 2025
Viewed by 936
Abstract
Glycated hemoglobin (HbA1c) is an important biomarker applied for the diagnosis, evaluation, and management of diabetes; therefore, its accurate determination is crucial. In this study, an innovative nanoplatform was developed, integrating carbon nanotubes (CNTs) with enhanced hydrophilicity achieved through cyclodextrin (CD) functionalization, and [...] Read more.
Glycated hemoglobin (HbA1c) is an important biomarker applied for the diagnosis, evaluation, and management of diabetes; therefore, its accurate determination is crucial. In this study, an innovative nanoplatform was developed, integrating carbon nanotubes (CNTs) with enhanced hydrophilicity achieved through cyclodextrin (CD) functionalization, and combined with gold nanoparticles (AuNPs) electrochemically deposited onto a screen-printed carbon electrode. The nanomaterials significantly improved the analytical performance of the sensor due to their increased surface area and high electrical conductivity. This nanoplatform was employed as a substrate for the covalent attachment of thiolated ferrocene-labeled HbA1c specific aptamer through Au-S binding. The electrochemical signal of ferrocene was covered by a stronger oxidation peak of Fe2+ from the HbA1c structure, leading to the elaboration of a nanostructured aptasensor capable of the direct detection of HbA1c. The electrochemical aptasensor presented a very wide linear range (0.688–11.5%), an acceptable limit of detection (0.098%), and good selectivity and stability, being successfully applied on real samples. This miniaturized, simple, easy-to-use, and fast-responding aptasensor, requiring only a small sample volume, can be considered as a promising candidate for the efficient on-site determination of HbA1c. Full article
Show Figures

Figure 1

15 pages, 2527 KB  
Article
A Disposable SWCNTs/AuNPs-Based Screen-Printed ISE at Different Temperatures to Monitor Ca2+ for Hypocalcemia Diagnosis
by Zhixue Yu, Hui Wang, Yue He, Ruipeng Chen, Xiangfang Tang and Benhai Xiong
Chemosensors 2025, 13(7), 252; https://doi.org/10.3390/chemosensors13070252 - 12 Jul 2025
Viewed by 673
Abstract
In this paper, screen-printed ion-selective electrodes combined with single-walled carbon nanotubes (SWCNTs) and gold nanoparticles (AuNPs) were used to rapidly and accurately measure serum Ca2+ concentration. Due to the susceptibility of cows to hypocalcemia after delivery, this disease can affect the health [...] Read more.
In this paper, screen-printed ion-selective electrodes combined with single-walled carbon nanotubes (SWCNTs) and gold nanoparticles (AuNPs) were used to rapidly and accurately measure serum Ca2+ concentration. Due to the susceptibility of cows to hypocalcemia after delivery, this disease can affect the health of cows and reduce milk production. Therefore, the development of an economical and swift detection method holds paramount importance for facilitating early diagnosis and subsequent treatment. In this study, by combining the high electrical conductivity and large surface area of SWCNTs with the strong catalytic activity of AuNPs, a SWCNTs/AuNPs composite with high sensitivity and good stability was prepared, achieving efficient selective recognition and signal conversion of Ca2+. The experimental results indicate that the screen-printed electrode modified with SWCNTs/AuNPs exhibited excellent performance in the determination of Ca2+ concentration. Its linear response range is 10−5.5–10−1 M, covering the normal and pathological concentration range of Ca2+ in cow blood, and the detection limit is far below the clinical detection requirements. In addition, the electrode also has good anti-interference ability and fast response time (about 15 s), showing good performance in the range of 5–45 °C. In practical applications, the combination of the electrode and portable detection equipment can realize the field rapid determination of cow blood Ca2+ concentration. This method is easy to operate, cost-effective, and easy to promote, providing strong technical support for the health management of dairy farms. Full article
(This article belongs to the Section Electrochemical Devices and Sensors)
Show Figures

Figure 1

14 pages, 1587 KB  
Article
Electrochemical Disposable Printed Aptasensor for Sensitive Ciprofloxacin Monitoring in Milk Samples
by Daniela Nunes da Silva, Thaís Cristina de Oliveira Cândido and Arnaldo César Pereira
Chemosensors 2025, 13(7), 235; https://doi.org/10.3390/chemosensors13070235 - 28 Jun 2025
Cited by 1 | Viewed by 787
Abstract
An electrochemical aptasensor was developed for the rapid and sensitive detection of ciprofloxacin (CPX) in milk samples. The device was fabricated on a polyethylene terephthalate (PET) substrate using a screen-printing technique with carbon-based conductive ink. Gold nanoparticles (AuNPs) were incorporated to enhance aptamer [...] Read more.
An electrochemical aptasensor was developed for the rapid and sensitive detection of ciprofloxacin (CPX) in milk samples. The device was fabricated on a polyethylene terephthalate (PET) substrate using a screen-printing technique with carbon-based conductive ink. Gold nanoparticles (AuNPs) were incorporated to enhance aptamer immobilization and facilitate electron transfer at the electrode surface. The sensor’s analytical performance was optimized by adjusting key parameters, including AuNP volume, DNA aptamer concentration, and incubation times for both the aptamer and the blocking agent (6-mercapto-1-hexanol, MCH). Differential pulse voltammetry (DPV) measurements demonstrated a linear response ranging from 10 to 50 nmol L−1 and a low detection limit of 3.0 nmol L−1. When applied to real milk samples, the method achieved high recovery rates (101.4–106.7%) with a relative standard deviation below 3.1%, confirming its robustness. This disposable and cost-effective aptasensor represents a promising tool for food safety monitoring, with potential for adaptation to detect other pharmaceutical residues in dairy products. Full article
Show Figures

Figure 1

22 pages, 5030 KB  
Article
Flexible Screen-Printed Gold Electrode Array on Polyimide/PET for Nickel(II) Electrochemistry and Sensing
by Norica Godja, Saied Assadollahi, Melanie Hütter, Pooyan Mehrabi, Narges Khajehmeymandi, Thomas Schalkhammer and Florentina-Daniela Munteanu
Sensors 2025, 25(13), 3959; https://doi.org/10.3390/s25133959 - 25 Jun 2025
Cited by 1 | Viewed by 878
Abstract
Nickel’s durability and catalytic properties make it essential in the aerospace, automotive, electronics, and fuel cell technology industries. Wastewater analysis typically relies on sensitive but costly techniques such as ICP-MS, AAS, and ICP-AES, which require complex equipment and are unsuitable for on-site testing. [...] Read more.
Nickel’s durability and catalytic properties make it essential in the aerospace, automotive, electronics, and fuel cell technology industries. Wastewater analysis typically relies on sensitive but costly techniques such as ICP-MS, AAS, and ICP-AES, which require complex equipment and are unsuitable for on-site testing. This study introduces a novel screen-printed electrode array with 16 chemically and, optionally, electrochemically coated Au electrodes. Its electrochemical response to Ni2+ was tested using Na2SO3 and ChCl-EG deep eutectic solvents as electrolytes. Ni2+ solutions were prepared from NiCl2·6H2O, NiSO4·6H2O, and dry NiCl2. In Na2SO3, the linear detection ranges were 20–196 mM for NiCl2·6H2O and 89–329 mM for NiSO4·6H2O. High Ni2+ concentrations (10–500 mM) were used to simulate industrial conditions. Two linear ranges were observed, likely due to differences in electrochemical behaviour between NiCl2·6H2O and NiSO4·6H2O, despite the identical Na2SO3 electrolyte. Anion effects (Cl vs. SO42−) may influence response via complexation or ion pairing. In ChCl-EG, a linear range of 0.5–10 mM (R2 = 0.9995) and a detection limit of 1.6 µM were achieved. With a small electrolyte volume (100–200 µL), nickel detection in the nanomole range is possible. A key advantage is the array’s ability to analyze multiple analytes simultaneously via customizable electrode configurations. Future research will focus on nickel detection in industrial wastewater and its potential in the multiplexed analysis of toxic metals. The array also holds promise for medical diagnostics and food safety applications using thiol/Au-based capture molecules. Full article
(This article belongs to the Section Chemical Sensors)
Show Figures

Figure 1

12 pages, 9594 KB  
Article
An Electrochemical Sensor Based on AuNPs@Cu-MOF/MWCNTs Integrated Microfluidic Device for Selective Monitoring of Hydroxychloroquine in Human Serum
by Xuanlin Feng, Jiaqi Zhao, Shiwei Wu, Ying Kan, Honemei Li and Weifei Zhang
Chemosensors 2025, 13(6), 200; https://doi.org/10.3390/chemosensors13060200 - 1 Jun 2025
Viewed by 1294
Abstract
Hydroxychloroquine (HCQ), a cornerstone therapeutic agent for autoimmune diseases, requires precise serum concentration monitoring due to its narrow therapeutic window. Current HCQ monitoring methods such as HPLC and LC-MS/MS are sensitive but costly and complex. While electrochemical sensors offer rapid, cost-effective detection, their [...] Read more.
Hydroxychloroquine (HCQ), a cornerstone therapeutic agent for autoimmune diseases, requires precise serum concentration monitoring due to its narrow therapeutic window. Current HCQ monitoring methods such as HPLC and LC-MS/MS are sensitive but costly and complex. While electrochemical sensors offer rapid, cost-effective detection, their large chambers and high sample consumption hinder point-of-care use. To address these challenges, we developed a microfluidic electrochemical sensing platform based on a screen-printed carbon electrode (SPCE) modified with a hierarchical nanocomposite of gold nanoparticles (AuNPs), copper-based metal–organic frameworks (Cu-MOFs), and multi-walled carbon nanotubes (MWCNTs). The Cu-MOF provided high porosity and analyte enrichment, MWCNTs established a 3D conductive network to enhance electron transfer, and AuNPs further optimized catalytic activity through localized plasmonic effects. Structural characterization (SEM, XRD, FT-IR) confirmed the successful integration of these components via π-π stacking and metal–carboxylate coordination. Electrochemical analyses (CV, EIS, DPV) revealed exceptional performance, with a wide linear range (0.05–50 μM), a low detection limit (19 nM, S/N = 3), and a rapid response time (<5 min). The sensor exhibited outstanding selectivity against common interferents, high reproducibility (RSD = 3.15%), and long-term stability (98% signal retention after 15 days). By integrating the nanocomposite-modified SPCE into a microfluidic chip, we achieved accurate HCQ detection in 50 μL of serum, with recovery rates of 95.0–103.0%, meeting FDA validation criteria. This portable platform combines the synergistic advantages of nanomaterials with microfluidic miniaturization, offering a robust and practical tool for real-time therapeutic drug monitoring in clinical settings. Full article
(This article belongs to the Special Issue Feature Papers on Luminescent Sensing (Second Edition))
Show Figures

Figure 1

25 pages, 899 KB  
Review
A Scoping Review of Vitamins Detection Using Electrochemically Polymerised, Molecularly Imprinted Polymers
by Mohd Azerulazree Jamilan, Balqis Kamarudin, Zainiharyati Mohd Zain, Kavirajaa Pandian Sambasevam, Faizatul Shimal Mehamod and Mohd Fairulnizal Md Noh
Polymers 2025, 17(10), 1415; https://doi.org/10.3390/polym17101415 - 21 May 2025
Cited by 2 | Viewed by 1247
Abstract
Vitamins are crucial micro-nutrients for overall well-being, making continuous monitoring essential. There are demands to provide an alternative detection, especially using a portable detection or a point-of-care-testing (POCT) device. One promising approach is employing an in situ electro-polymerised MIP (eMIP), which offers a [...] Read more.
Vitamins are crucial micro-nutrients for overall well-being, making continuous monitoring essential. There are demands to provide an alternative detection, especially using a portable detection or a point-of-care-testing (POCT) device. One promising approach is employing an in situ electro-polymerised MIP (eMIP), which offers a straightforward polymerisation technique on screen-printed electrodes (SPEs). Here, we report a review based on three databases (PubMed, Scopus, and Web of Science) from 2014 to 2024 using medical subject heading (MeSH) terms “electrochemical polymerisation” OR “electropolymerisation” crossed with the terms “molecularly imprinted polymer” AND “vitamin A” OR “vitamin D” OR “vitamin E” OR “vitamin K” OR “fat soluble vitamin” OR “vitamin B” OR “vitamin C” OR “water soluble vitamin”. The resulting 12 articles covered the detection of vitamins in ascorbic acid, riboflavin, cholecalciferol, calcifediol, and menadione using monomers of catechol (CAT), 3,4-ethylenedioxythiophene (EDOT), o-aminophenol (oAP), o-phenylenediamine (oPD), pyrrole, p-aminophenol (pAP), p-phenylenediamine (pPD), or resorcinol (RES), using common bare electrodes including graphite rod electrode (GRE), glassy carbon electrode (GCE), gold electrode (GE), and screen-printed carbon electrode (SPCE). The most common electrochemical detections were differential pulse voltammetry (DPV) and linear sweep voltammetry (LSV). The imprinting factor (IF) of the eMIP-modified electrodes were from 1.6 to 21.0, whereas the cross-reactivity was from 0.0% to 29.9%. Several types of food and biological samples were tested, such as supplement tablets, poultry and pharmaceutical drugs, soft drinks, beverages, milk, infant formula, human and calf serum, and human plasma. However, more discoveries and development of detection methods needs to be performed, especially for the vitamins that have not been studied yet. This will allow the improvement in the application of eMIPs on portable-based detection and POCT devices. Full article
(This article belongs to the Special Issue Molecularly Imprinted Polymers: Latest Advances and Applications)
Show Figures

Graphical abstract

16 pages, 1919 KB  
Article
Multi-Parametric Electrochemical Sensing Platform: Applications in Animal Welfare
by C. Ferreira, E. Lynch, A. O’Herlihy, F. Barry, L. C. Nagle, S. R. Teixeira and P. Galvin
Biosensors 2025, 15(5), 304; https://doi.org/10.3390/bios15050304 - 10 May 2025
Viewed by 901
Abstract
The rapid growth of the dairy sector requires advanced monitoring tools to ensure sustainable practices that benefit the environment, economy, and human health. Current monitoring devices often lack multi-parametric capabilities, limiting their ability to provide comprehensive data on critical chemical and biochemical parameters. [...] Read more.
The rapid growth of the dairy sector requires advanced monitoring tools to ensure sustainable practices that benefit the environment, economy, and human health. Current monitoring devices often lack multi-parametric capabilities, limiting their ability to provide comprehensive data on critical chemical and biochemical parameters. To address this challenge, this work presented the integration of a real-time multi-parametric device with sensors for pH, temperature, nitrate, and nitrite, providing a comprehensive solution to dairy cattle health monitoring. This solution included an electrochemical platform, Portable Unit for Lab-on-Site Electrochemistry (PULSE), and an application for data processing and display. In-house fabricated flexible gold-printed electrodes demonstrated accurate detection of nitrite and nitrate when integrated with the PULSE, achieving sensitivities of 6.32 μA/ppm/cm2 in artificial interstitial fluid and 1.92 μA/ppm/cm2 in phosphate buffered saline, respectively. The PULSE achieved 65.83% and 58.3% lower limits of detection in phosphate buffered saline than a benchtop potentiostat, for nitrate and nitrite, respectively, along with a 24.5% increase in nitrite sensitivity, enhancing its ability to detect lower analyte concentrations. pH sensing was carried out with a commercial screen-printed electrode coated with a layer of iridium oxide. The pH was tested in ruminal complex fluid, obtaining a pH sensitivity of −59.63 mV/pH and an accuracy of 98.9%. These findings highlighted the potential of this technology as an effective tool for dairy cattle health monitoring and its deployment in real-world scenarios. Full article
Show Figures

Figure 1

16 pages, 2711 KB  
Article
Ultrasensitive Peptide-Based Electrochemical Biosensor for Universal Diagnostic of Dengue
by Isis Campos Prado, João Pedro Rangel da Silva Carvalho, André Souza Araujo, Paloma Napoleão-Pêgo and Salvatore Giovanni De-Simone
Biosensors 2025, 15(4), 236; https://doi.org/10.3390/bios15040236 - 8 Apr 2025
Viewed by 1591
Abstract
Dengue is a neglected disease mainly affecting tropical and subtropical countries. The diagnosis of dengue fever is still a problem since most of it is made from whole or recombinant DENV proteins, which present cross-reactions with other members of the Flavivirus family. Therefore, [...] Read more.
Dengue is a neglected disease mainly affecting tropical and subtropical countries. The diagnosis of dengue fever is still a problem since most of it is made from whole or recombinant DENV proteins, which present cross-reactions with other members of the Flavivirus family. Therefore, there is still a huge demand for new diagnostic methods that provide rapid, low-cost, easy-to-use confirmation. Thus, in this study, we developed an affordable electrochemical biosensor for rapidly detecting immunoglobulin G (IgG) serological antibodies in the sera of DENV-infected patients. An identified linear B-cell epitope (DENV/18) specific for DENV 1–4 serotypes recognized by IgG in patient sera was selected as a target molecule after a microarray of peptides using the SPOT-synthesis methodology. After chemical synthesis, the DENV/18-peptide was immobilized on the surface of the working electrode of a commercially available screen-printed gold electrode (SPGE). The capture of DENV-specific IgG allowed for the formation of an immunocomplex that was measured by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) using a potassium ferrocyanide/ferricyanide ([Fe(CN)6]3−/4−) electrochemical probe. An evaluation of the biosensor’s performance showed a detection limit of 100 µg mL−1 for the synthetic peptides (DENV/18) and 1.21 ng mL−1 in CV and 0.43 ng mL−1 in DPV for human serum, with a sensitivity of 7.21 µA in CV and 8.79 µA in DPV. The differentiation of infected and uninfected individuals was possible even at a high dilution factor that reduced the required sample volumes to a few microliters. The final device proved suitable for diagnosing DENV by analyzing real serum samples, and the results showed good agreement with molecular biology diagnostics. The flexibility to conjugate other antigenic peptides to SPEs suggests that this technology could be rapidly adapted to diagnose other pathogens. Full article
(This article belongs to the Special Issue Biosensing and Diagnosis—2nd Edition)
Show Figures

Graphical abstract

Back to TopTop