Impact of First Tower Earthing Resistance on Fast Front Back-Flashover in a 66 kV Transmission System

  • Abdullah H. Moselhy,
  • Abdelaziz M. Abdel-Aziz,
  • Mahmoud Gilany and
  • Ahmed Emam

8 September 2020

Lightning stroke on a transmission tower structure is one of the major reasons that results in high voltages at the tower arms due to the excessive lightning current flowing through the transmission tower to earth. The Surge voltage seen at the tower...

  • Article
  • Open Access
29 Citations
5,694 Views
20 Pages

Evaluation of the Transient Overvoltages of HVDC Transmission Lines Caused by Lightning Strikes

  • Amr S. Zalhaf,
  • Ensheng Zhao,
  • Yang Han,
  • Ping Yang,
  • Abdulrazak H. Almaliki and
  • Reda M. H. Aly

16 February 2022

High-voltage direct-current (HVDC) transmission systems are considered an outstanding solution due to high electrical losses emerging from long-distance transmission. However, HVDC transmission lines (TLs) are vulnerable to lightning strikes. In this...

  • Article
  • Open Access
2 Citations
2,778 Views
17 Pages

10 December 2020

Earthing and protective devices such as line surge arrestors (LSAs) play an important role in areas with high lightning occurrence for overhead HVAC lines’ performance. A lightning stroke of high magnitude can lead to back flash-overs, and the...

  • Article
  • Open Access
10 Citations
2,839 Views
17 Pages

10 January 2023

Due to micro landforms and climate, the 110 kV transmission lines crossing the mountain areas are exposed to severe icing conditions for both their high voltage (HV) conductors and shield wires during the winter. Ice accumulation on the shield wire c...

  • Article
  • Open Access
8 Citations
6,839 Views
20 Pages

Impact of Earthing System Designs and Soil Characteristics on Tower Footing Impedance and Ground Potential Rise: A Modelling Approach for Sustainable Power Operation

  • Nur Alia Farina Mohamad Nasir,
  • Mohd Zainal Abidin Ab Kadir,
  • Miszaina Osman,
  • Muhamad Safwan Abd Rahman,
  • Ungku Anisa Ungku Amirulddin,
  • Mohd Solehin Mohd Nasir,
  • Nur Hazirah Zaini and
  • Nik Hakimi Nik Ali

27 July 2021

Improving a tower earthing system by reducing the impedance is an effective solution to prevent back flashover from occurring and thus maintaining the sustainable operation of power supply. Knowledge of the soil and earthing structure is an important...

  • Article
  • Open Access
10 Citations
3,274 Views
13 Pages

Research on Lifespan Prediction of Composite Insulators in a High Altitude Area Experimental Station

  • Yi Zhang,
  • Zhijin Zhang,
  • Xingliang Jiang,
  • Tian Liang and
  • Dongdong Zhang

15 August 2019

In this paper, composite insulators of the same batch from Factory A, aged for 1–12 years in a high altitude area experimental station of Hunan province, were sampled. In order to investigate the changing law of lifespan prediction parameters w...

  • Article
  • Open Access
21 Citations
7,413 Views
31 Pages

20 August 2019

This paper evaluates the effect of a lightning strike directly on the 24 kV distribution lines in Thailand, where such strikes are one of the main causes of power outages. The voltage across the insulator, and the arrester energy absorbed due to the...

  • Article
  • Open Access
19 Citations
3,796 Views
12 Pages

Analysis of Pollution in High Voltage Insulators via Laser-Induced Breakdown Spectroscopy

  • Xinwei Wang,
  • Shan Lu,
  • Tianzheng Wang,
  • Xinran Qin,
  • Xilin Wang and
  • Zhidong Jia

13 February 2020

Surface pollution deposition in a high voltage surface can reduce the surface flashover voltage, which is considered to be a serious accident in the transmission of electric power for the high conductivity of pollution in wet weather, such as rain or...

  • Article
  • Open Access
14 Citations
4,122 Views
22 Pages

Application of Mineral Compounds for a High-Voltage Portable Grounding System: An Experimental Study

  • Rizwan Ahmad,
  • Mahmoud Kassas,
  • Chokri B. Ahmed,
  • Faisal Khan,
  • Sikandar Khan,
  • Arshad Jamal and
  • Irshad Ullah

23 August 2021

Electrical grounding is an indispensable part of the power system network. The grounding system is mainly affected by grounding resistance and the nature of the soil. High ground resistance produces the phenomenon of soil ionization, surface arching,...

  • Article
  • Open Access
11 Citations
4,856 Views
18 Pages

7 March 2023

The icing of glass insulators is likely to cause faults such as insulator flashover, which poses a serious threat to the power system. Traditional deicing techniques have the disadvantage of being costly and inefficient. Herein, polytetrafluoroethyle...

  • Article
  • Open Access
12 Citations
3,356 Views
17 Pages

Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current Limiter

  • Changfu Chen,
  • Yongxia Han,
  • Junxiang Liu,
  • Wenxiong Mo,
  • Zhao Yuan,
  • Jianning Huang,
  • Haibo Su,
  • Xiancong Zhang and
  • Kaijian Wu

11 October 2019

As one of the key technologies to solve the problem of high short-circuit current, the fault current limiter (FCL) has become a research hotspot in China and abroad. The overvoltage and protection measures of the FCL are the key technologies for its...