Abstract
Passengers routinely carry numerous Portable Electronic Devices (PEDs) powered by lithium-ion batteries, which present hazards when subjected to thermal runaway, including emission of toxic gases, smoke generation and potential fires. The LOKI-PED project investigates the severity of such events in aircraft cabins by experimentally characterizing combustion gases, validating a zonal cabin model and predicting exposure to harmful substances and smoke. PEDs were deliberately forced into thermal runaway in both burn chamber and A320 cabin mockup tests, enabling the quantification of emitted carbon dioxide and toxic compounds such as carbon monoxide, formaldehyde, hydrogen fluoride, and hydrogen chloride. These measurements were correlated to CO2 peak concentrations, enabling a factor-based scaling approach for full-scale cabin simulations. A validated zonal model was then used to predict the temporal and spatial spread of gases and smoke in the cabin, cockpit and galley. Results show that while cabin ventilation generally keeps exposure below harmful levels, the cockpit and galley are significantly more vulnerable. The study highlights the importance of rapid crew response, limitations on PED battery capacities and operational mitigation strategies to ensure flight safety.