Abstract
Rotor spacing couples energy capture and hydrodynamic loading in confined turbine arrays. Two-dimensional unsteady Reynolds-averaged simulations with the SST <i>k</i>–<i>w</i> model evaluate ten spacings and nine tip-speed ratios for side-by-side co-rotating Savonius hydrokinetic turbines. Directional and vector-resultant loads are compared at each spacing’s highest-power sampled point. Cycle and averaging-window comparisons assess temporal stability; covariance decomposition and sampled peaks characterize the directional response. The closest spacing (<i>s</i> = 1.167) gives a mean power coefficient of 0.651 at <i>λ</i> = 1.4. Increasing the spacing to <i>s</i> = 1.361 retains 99.53% of this output while reducing the mean resultant-force coefficient by 2.21%, resultant-force RMS fluctuation by 14.03%, and thrust RMS fluctuation by 17.68%. Lateral-force RMS fluctuation increases by 13.61%. At a fixed blockage ratio of 0.480, spacing redistributes the central and sidewall passages, changing blade pressure loading and power sharing. The second-closest arrangement therefore combines near-maximum power with lower thrust and resultant fluctuations when the support accommodates the increased lateral demand. This joint assessment provides a quantitative basis for selecting spacing according to energy capture and directional support requirements in the modeled channel.