Abstract
Addressing the bottlenecks of separated concentration and defluorination units, high energy consumption, and low mass-transfer efficiency in wet-process phosphoric acid (WPA) refining, a novel integrated process for air-stripping concentration and defluorination in a turbulent ball contactor (TBC) is proposed within the thermodynamic framework of closed-loop tail-gas recycling in the process industry. The circulating gas simultaneously acts as a mass-transfer carrier, a heat-transfer carrier, and a medium for gas–liquid interfacial renewal and process intensification, thereby creating a triple “carrier–interface–intensification” effect. Theoretical analysis indicates that, under excess SiO2, the thermal decomposition of fluorosilicic acid and the reaction of HF with SiO2 can directionally generate highly volatile SiF4, thus achieving synchronous fluoride stripping and suppressing the formation of metal–fluoride complexes. In an industrial demonstration unit of Φ0.62 m × 9 m, three layers of lightweight hollow polypropylene spheres with a total static bed height of 1.5 m were used to treat hemihydrate wet-process crude phosphoric acid containing approximately 40 wt% P2O5 and >1.15 wt% F at atmospheric pressure. The results show that the suitable superficial gas velocity is 1.7–3.5 m/s, the liquid spray density is 49~99 m3/(m2·h), and the phosphoric acid throughput is 11–23 t/d (P2O5). The product contains >58 wt% P2O5 and <0.1 wt% F; the P2O5/F mass ratio increases from approximately 35 to above 726, the defluorination efficiency reaches 92–94%, and the steam consumption is reduced by 15.1% compared with the vacuum stripping defluorination process. Fluidization and mass-transfer analyses reveal that bed expansion and pressure drop are synergistically controlled by the gas-phase Reynolds number ReG and the liquid-phase Reynolds number ReL. The gas-phase overall height of a transfer unit (HTU) is 0.9–1.6 m and decreases significantly with increasing liquid-to-gas volume ratio. An empirical correlation is established as HTU = 673.98 × ReG −0.345 × ReL −0.353, with R2 = 0.7301, RMSE = 0.0807 m, and relative deviations between calculated and experimental values within ±15%. In addition, Sh = 9.95 × 10−8 × ReG1.5753 × ReL0.2489 × Sc1/3, with R2 = 0.9922, an average relative error of 2.89%, and a maximum relative error of 5.95%. This process enables simultaneous phosphoric acid concentration and deep defluorination in a single column, providing new principles, new methods, and fundamental scale-up data for green refining of WPA.
1. Introduction
Process-industry tail-gas abatement traditionally relies on an end-of-pipe dilution–emission paradigm, in which large-volume fresh air acts as a heat-and-mass carrier for pollutant dispersion to the atmosphere. For wet-process phosphoric acid (WPA) production, this conventional route yields a free-energy dissipation ratio up to 2.54, indicating pollutant-dispersion-related exergy loss surpasses the effective exergy for product manufacturing by 154% [1]. Dilute vent streams hinder economical recovery of low-grade heat and chemical species, raising carbon footprints and resource waste across phosphorus-chemical chains [2]. Closed-loop tail-gas recycling recovers waste heat and valuable components from off-gas and reintroduces them into production, reconciling pollution mitigation with material processing toward near-zero-emission targets [1]. Nevertheless, its industrial deployment is restricted by insufficient fundamental data on multiphase hydrodynamics and interfacial mass transfer for high-viscosity, impurity-laden process fluids [3].
WPA serves as a critical intermediate for phosphate fertilizers and fine phosphorus chemicals, where defluorination determines final product quality [4]. In crude hemihydrate WPA, fluorine mainly occurs as fluorosilicic acid, hydrofluoric acid, and metal–fluoride complexes generated with ore-derived multivalent cations (Al3+, Fe3+) [5]. Established defluorination technologies, including chemical precipitation, vacuum concentration, and air stripping, suffer from inherent drawbacks: precipitation introduces foreign ions and solid-waste burdens [6]; vacuum concentration requires expensive vacuum infrastructure and high-temperature operation that accelerates equipment corrosion [7]; conventional packed-column stripping suffers from poor interfacial renewal, low volumetric mass-transfer efficiency, and severe scaling induced by supersaturated impurities [8]. Mechanistic investigations reveal that elevated temperature accelerates fluorine release, whereas metal cations suppress fluoride volatilization by complexation [9]. Dosing excess active SiO2 shifts chemical equilibria to form volatile SiF4, mitigating complexation and improving defluorination performance [10]. Although emerging approaches such as solvent extraction and multistage cascade stripping have been reported [11], atmospheric-pressure single-unit integration of WPA concentration and deep defluorination remains largely underexplored, lacking reliable scale-up parameters [12].
A turbulent ball contactor (TBC) is an intensified three-phase column utilizing fluidization to enhance gas–liquid mass transfer [13]. Lightweight hollow spheres are fluidized by gas flow to continuously refresh gas–liquid interfaces, enabling high superficial gas velocity and throughput compared with static packed towers [14]. Sphere–sphere collisions endow TBCs with self-cleaning capacity to resist fouling [15]. CFD simulations have characterized TBC hydrodynamics such as bed expansion, liquid holdup, and pressure drop for general gas–liquid systems [16,17,18], and pilot trials confirm its feasibility for phosphorus-chemical tail-gas purification [19]. However, existing studies mostly focus on dilute low-viscosity absorption systems; mass-transfer data for high-viscosity impurity-rich WPA under coupled evaporation–reactive-stripping conditions are scarce [20,21,22].
For closed-loop TBC stripping of WPA, circulating gas performs three roles: a mass-transfer carrier for SiF4, heat carrier supplying evaporation latent heat, and turbulence generator for interfacial renewal [23]. This operation differs fundamentally from conventional TBC absorption without simultaneous solvent evaporation and reactive stripping [24,25,26]. Viscous phosphoric acid further complicates hydrodynamic behaviors and mass-transfer-resistance distribution [27].
Herein, we propose and industrially validate an integrated TBC process for simultaneous air-stripping concentration and deep defluorination of hemihydrate WPA under closed-loop tail-gas recycling principles [28]. Experiments are conducted on a Φ 0.62 m × 9 m industrial demonstration unit filled with hollow polypropylene spheres. We systematically investigate operational windows, fluidization features (bed expansion, pressure drop), and mass-transfer performance represented by gas-phase height of transfer unit (HTU) and Sherwood number (Sh) [29]. Empirical correlations for HTU and Sh are regressed from industrial-scale measurements. This work aims (i) to interpret the “carrier–interface–intensification” triple-effect mechanism for circulating-gas stripping inside TBCs; (ii) to develop hydrodynamic-mass-transfer correlations applicable for high-viscosity WPA systems; and (iii) to provide scale-up fundamentals for green intensified WPA refining [30]. The rest of this article is structured as follows: Section 2 presents theoretical principles; Section 3 describes experimental setup and analytical methods; Section 4 discusses experimental results; Section 5 summarizes major conclusions.
2. Theoretical Analysis
2.1. Thermodynamic Basis of Closed-Loop Tail-Gas Recycling
According to the generalized production system model, environmental pollution control in the process industry should be considered together with product processing. Let ΔGprod be the effective free-energy consumption of the product-processing process and ΔGemis be the free-energy dissipation of the pollutant emission–dispersion process. The free-energy dissipation ratio RFED is defined as:
RFED = ΔGemis/ΔGprod
Taking the WPA industry as a model, RFED = 2.54, i.e., the emission free-energy dissipation exceeds the effective free-energy consumption by 154%, for the closed-loop route, the emission–dispersion subprocess vanishes, ΔGemis = 0 and RFED = 0. The closed-loop route also lowers the product-processing free-energy demand from 485.3 MJ to 228.5 MJ (driving force reduced by more than 50%) and increases the free energy embodied in recovered products [1]. This huge waste originates from the end-of-pipe emission mode that abuses air as the heat/mass carrier. Closed-loop tail-gas recycling separates and recovers low-grade heat/mass from the discharged tail gas and returns them to the system, fundamentally changing the structure of free-energy consumption and representing a fundamental technological route for sustainable development of the process industry.
From a thermodynamic perspective, the end-of-pipe emission mode dilutes pollutants with large amounts of fresh air. Although this reduces the local pollutant concentration, it significantly increases the mixing entropy of the system and the subsequent separation burden, making low-grade heat/mass difficult to recover. In contrast, closed-loop recycling increases the enrichment of target components in the circulating gas, making water vapor and fluorine-containing components easier to separate in condensation, washing, and other units. Thus, free energy originally dissipated to the environment is reincorporated into the production process.
2.2. Physicochemical Principles of Air-Stripping Concentration and Defluorination
The existence forms of fluorine in WPA are closely related to phosphoric acid concentration, silicon content, and temperature. In hemihydrate wet-process crude phosphoric acid (approximately 40% P2O5, with SiO2 mass fraction typically 0.3–0.8%), fluorine exists mainly as fluorosilicic acid (H2SiF6) and its dissociation products (SiF62−, H, etc.). When the molar ratio of SiO2 to fluoride in the system is excessive (i.e., n(SiO2)/n(F) > 0.25), the chemical equilibrium of fluorine shifts significantly toward the formation of volatile SiF4. This characteristic is the core basis for the design of the air-stripping defluorination process.
For the main defluorination reaction pathways, in the presence of excess SiO2, the following key reactions occur during heating and stripping:
- (1)
- Thermal decomposition of fluorosilicic acid:
This reaction becomes significant above 80 °C. If the generated HF is not removed in time, it reacts with metal impurities in phosphoric acid (such as Fe3+, Al3+) to form nonvolatile fluoride complexes, reducing defluorination efficiency. The presence of excess SiO2 provides a rapid side reaction pathway for consuming HF.
- (2)
- Reaction of HF with excess SiO2:
This reaction is relatively fast in acidic media, and the product SiF4 is gaseous while water enters the liquid phase, introducing no new impurities. Combining reactions (1) and (2), the overall reaction is:
The overall reaction shows that, under excess SiO2, only 1 mol of SiO2 is consumed per 2 mol of H2SiF6 decomposed, and all fluorine can be removed by stripping in the form of SiF4, with water as a byproduct. The advantages of this reaction pathway are as follows: accumulation of the intermediate HF in the liquid phase is avoided, thereby suppressing side reactions in which fluorine forms nonvolatile complexes with metal ions in phosphoric acid; at atmospheric pressure, the volatility of SiF4 (boiling point −86 °C) is much higher than that of HF (boiling point 19.5 °C), making it easier to enter the gas phase under atmospheric stripping conditions and providing a larger mass-transfer driving force; and the water generated by the reaction helps maintain the fluidity of phosphoric acid and prevents excessively high viscosity or scaling caused by over-concentration.
From the perspective of coupling chemical equilibrium and mass transfer, the addition of SiO2 not only changes the speciation of fluorine but also reduces the activity of HF in the liquid phase by consuming HF, causing reaction (2) to proceed continuously to the right. Meanwhile, the stripping process continuously removes SiF4 from the gas phase, further reducing the apparent concentration of fluorine in the liquid phase and forming a synergistic “reaction–stripping” driving force. Water evaporation increases the phosphoric acid concentration, but excessively high viscosity increases liquid-film mass-transfer resistance. Therefore, concentration and defluorination must be coordinately controlled under suitable temperature, gas velocity, and liquid-to-gas ratio.
2.3. Height of a Transfer Unit in a TBC
The core hydrodynamic feature that distinguishes a TBC from a conventional packed column is that, under suitable operating gas velocities, the lightweight spheres in the column are fluidized, and the two gas–liquid phases and spheres move vigorously. The concentration and temperature within the bed tend to be uniform. This feature allows each TBC packing layer to be approximately regarded as a perfectly mixed unit, thereby simplifying the calculation of the number of transfer units. The column consists of three identical fluidized beds separated by inter-layer liquid redistributors. Within each bed, the intense turbulent motion homogenizes the gas–liquid concentration and temperature, so that a single bed is approximated as a perfectly mixed unit; the three beds are treated as three perfectly mixed units connected in series.
For the air-stripping concentration process, mass transfer of water from the liquid phase to the gas phase is the controlling step. In the TBC packing bed, the rapid turbulent motion of the spheres leads to a wide residence time distribution of the liquid phase, satisfying the basic conditions of the perfectly mixed flow model. The layer-wise perfectly mixed state is therefore adopted as an engineering approximation for scale-up correlation development. Let the total height of the TBC packing layer be H. The total number of transfer units is the sum of those of the three layers; the column-averaged gas-phase overall height of a transfer unit HTU still satisfies:
HTU comprehensively reflects the combined influence of gas–liquid two-phase mass-transfer resistance, effective interfacial contact area, and operating conditions. It is a core parameter for evaluating the mass-transfer performance of a packing layer. A smaller value indicates a lower packing height required to accomplish a unit mass-transfer task and a higher mass-transfer efficiency.
For the physical meaning and calculation method of HTU, the strict definition of the gas-phase overall height of a transfer unit is:
where Gm is the molar flow rate of inert gas (circulating gas excluding water vapor), in kmol/s; KG is the gas-phase overall mass-transfer coefficient, in kmol/(m2·s); a is the effective specific surface area, in m2/m3; and Ω is the column cross-sectional area, in m2. According to this definition, HTU is determined jointly by operating conditions (Gm), the mass-transfer coefficient (KG), and equipment structural parameters (Ω).
In experimental data processing, HTU is usually back-calculated from the integral definition of the number of transfer units N. Because the vapor–liquid equilibrium of water in phosphoric acid is complex (affected by phosphoric acid concentration, temperature, and fluorides) and varies continuously along the column height, direct integration is difficult. Based on measured gas-phase compositions and temperature distributions at the top and bottom of the column, combined with material balance, the logarithmic-mean N value is calculated as:
where y1 and y2 are the water vapor mole fractions in the circulating gas at the column bottom and top, respectively (the concentration index used for the mass-transfer process in this work), y∗ is the gas-phase water vapor mole fraction in equilibrium with the liquid-phase bulk concentration, and Δym is the logarithmic mean driving force for the mass-transfer process, expressed in terms of the gas-phase water vapor mole fraction. The flow-pattern approximation and the logarithmic-mean treatment are common to all operating points; their systematic bias acts in the same direction and is absorbed into the regressed correlation coefficients, lying within the reported regression accuracy.
3. Experimental Apparatus and Methods
3.1. Industrial Demonstration Unit
The experiments were carried out in a multi-layer air-stripping phosphoric acid concentration and defluorination TBC industrial demonstration unit of Φ0.62 m × 9 m. The column body was made of 316L stainless steel, with a total height of 9.0 m and an inner diameter of 0.62 m, designed for atmospheric operation. Three TBC packing beds were arranged inside the column, each with a static packing height of 0.5 m and a total static height of 1.5 m. Each packing section consisted of a bottom support plate, a TBC packing layer, and a top retaining screen. Liquid redistributors were installed between layers to ensure uniform liquid distribution along the column cross-section.
The TBC packing consisted of hollow polypropylene spheres with a nominal diameter of 38 mm, a wall thickness of 1.0–1.2 mm, a packed voidage of approximately 0.85, and a bulk density of approximately 120 kg/m3, supplied by Yixin Packing Co., Ltd., Shangyu, China. The hollow structure significantly reduces the apparent density of the spheres, enabling fluidization at relatively low gas velocities. The sphere surfaces possess self-cleaning characteristics during turbulent collisions, effectively suppressing clogging caused by phosphoric acid scaling.
A circulating gas inlet and a concentrated phosphoric acid outlet were arranged at the bottom of the column, and a circulating gas outlet and a crude phosphoric acid inlet were arranged at the top. A mist eliminator, supplied by Sichuan Kexin Mechanical and Electrical Equipment Co., Ltd., Deyang, China, was installed at the top to capture droplets entrained in the circulating gas. Multiple temperature (Pt100 resistance thermometer, Chuanyi Sensor Co., Ltd., Chongqing, China) and pressure (pressure transmitter, Chuanyi Sensor Co., Ltd., Chongqing, China) measurement points and liquid sampling ports were arranged along the column height for real-time monitoring of operating conditions and sample collection.
3.2. Process Flowsheet
The process flowsheet is shown in Figure 1. Wet-process crude phosphoric acid (approximately 40 wt% P2O5) was first transported to the phosphoric acid premixing tank B1, where excess active SiO2 was added at a set ratio (initial SiO2/F molar ratio controlled at approximately 0.4) and stirred uniformly. The mixed slurry overflowed to the phosphoric acid transfer tank B2 and was fed by the transfer pump into the stripping defluorination circulation tank B3.
Figure 1.
Process flowsheet; B1—premixing tank; B2—transfer tank; B3—circulation tank; B4—mist eliminator; T1—turbulent ball contactor; T2—primary water scrubber; T3—secondary water scrubber; T4—electrostatic mist precipitator; F1—fan; H1—heater; P1/2/3—pumps.
The phosphoric acid in circulation tank B3 was sent by the circulation pump to graphite heat exchanger H1, heated to 105–110 °C, and then entered the top of TBC T1. Circulating gas from circulation fan P1 entered the bottom of T1. The gas and liquid phases contacted countercurrently in the column, completing water vapor evaporation and stripping removal of fluorides (mainly SiF4). Part of the phosphoric acid discharged from the column bottom was output as product through a three-way pipeline at the outlet of the defluorination circulation pump (P2O5 concentration >58%, F concentration <0.1%), and the remainder returned to circulation tank B3. The tail gas from the top of the column sequentially entered primary water scrubber T2 and secondary water scrubber T3. After washing, the fluorine content in the tail gas was ≤3 mg/m3. The gas then entered electrostatic mist precipitator T4, and the outlet droplet content was ≤5 mg/m3. The purified tail gas was returned to TBC T1 by induced draft fan P1 for reuse, forming a closed-loop tail-gas cycle.
3.3. Operating Conditions and Operational Parameters
The experimental operating conditions covered the following parameter ranges: superficial gas velocity, 1.7–3.5 m/s; phosphoric acid spray density, 49~99 m3/(m2·h); circulating gas inlet temperature, 50–65 °C; phosphoric acid inlet temperature, 105–110 °C; operating pressure, atmospheric; phosphoric acid throughput, 11–23 t/d (P2O5). During the experiments, the system operated continuously and stably, and samples were periodically collected at each measurement point for chemical analysis. The gas phase was analyzed for water vapor content, and the liquid phase was analyzed for P2O5 and F concentrations. The P2O5 concentration in phosphoric acid was determined by the quinoline phosphomolybdate gravimetric method (GB/T 1871.1–1995) [31]; the F concentration was determined by the fluoride ion-selective electrode method (GB/T 1872–1995) [32]. The water vapor mole fraction in the circulating gas was measured jointly by a wet-and-dry-bulb thermometer and a dew-point meter. Gas velocity was measured by a standard Pitot tube and a differential pressure transmitter; liquid flow rate was measured by an electromagnetic flowmeter; temperature was measured by Pt100 resistance thermometers; and pressure was measured by pressure transmitters.
4. Results and Discussion
4.1. Product Specifications and Energy Consumption
Under the optimal operating conditions (superficial gas velocity 1.8 m/s, liquid-to-gas volume ratio 3.5, circulating gas inlet temperature 65 °C), the system operated continuously and stably. The main specifications of the product phosphoric acid are shown in Figure 2.
Figure 2.
Comparison of process parameters between air-loop concentration–defluorination and vacuum concentration/stripping defluorination.
Figure 2 compares key process parameters between the air-loop concentration–defluorination process normally operated by the Chanheng Group and the vacuum stripping defluorination process under continuous operation for 72 h. After integrated TBC air-stripping concentration and defluorination, the P2O5 concentration of phosphoric acid increased from approximately 40% to above 58%, an increase of more than 43%. The fluorine content decreased from approximately 1% to below 0.1%, and the defluorination efficiency reached 92–94%. The P2O5/F mass ratio increased from approximately 40 to above 726, far exceeding the quality requirements of industrial-grade phosphoric acid. These results indicate that the integrated process can simultaneously achieve concentration and defluorination in a single device, verifying the feasibility and technical–economic performance of the process. The steam consumption of the air-loop concentration–defluorination process was 0.732 t/tP2O5, while that of the vacuum stripping defluorination process was 0.862 t/tP2O5. Compared with the vacuum stripping defluorination process, the steam consumption of the air-loop concentration–defluorination process was reduced by 15.1%, showing significant energy-saving advantages. In terms of operating temperature, the maximum operating temperature of the air-loop concentration–defluorination system was 108 °C, while that of the vacuum concentration/stripping defluorination process reached 120 °C, i.e., the latter was 14.1% higher. A higher operating temperature imposes stricter temperature and corrosion resistance requirements on equipment materials, easily aggravating equipment corrosion and loss. The air-loop concentration–defluorination process operates at a lower temperature, which can effectively alleviate the material tolerance pressure caused by high temperature, reduce the difficulty of material selection, and lower equipment-loss risk. The above 15.1% reduction is based on process steam consumption per ton of P2O5, a widely adopted energy-performance benchmark in the wet-process phosphoric acid industry. To comprehensively evaluate the overall energy-saving effect, auxiliary power consumption was also accounted for. Under typical operating conditions, the circulation fan shaft power is approximately 1.8 kW (circulating gas flow of 1500 Nm3/h, system pressure drop of ~3 kPa, and fan efficiency of 70%), while auxiliary pumps and instruments consume about 0.6 kW in total. Based on an average output of 17 t/d, the total auxiliary power consumption is approximately 2.54 kWh/t P2O5. In standard coal equivalent, the steam saving corresponds to about 16.7 kgce/t P2O5, whereas the additional power consumption corresponds to only 0.31 kgce/t P2O5. These results indicate that the additional power consumption of the closed-loop circulation system is far less than the steam saving, and the comprehensive energy-saving rate remains at approximately 14.8%.
Under the representative steady condition, the fresh crude acid feeds at 1.1 m3/h (ρ = 1.47 t/m3) with 1.15 wt% F, and the product acid is withdrawn at 0.76 m3/h (ρ = 1.68 t/m3) with 0.08 wt% F; the liquid-phase defluorination efficiency is 94.5%, and the residual free SiO2 in the product acid is about 0.1 wt%. The fluoride in the purified closed-loop vent gas is below 3 mg/m3 at 1500 Nm3/h. Most fluoride is expected to be recovered by the two-stage water scrubbers, in agreement with the directional formation of volatile SiF4. The independently measured scrubbing recovery, the SiF4 molar yield and the balance closure, based on scrubbing-liquor and speciation analyses, are to be supplemented in a follow-up study.
4.2. Fluidization Characteristics of the TBC
The fluidization behavior of lightweight packing in a TBC is the result of the combined action of gas–liquid two-phase drag, gravity, buoyancy, and bed turbulence, directly determining gas–liquid contact efficiency and operating stability. Given the extremely low residual SiO2 content in the liquid phase, the influence of suspended solids on hydrodynamic behavior is not considered in the following analysis. In this section, the relative bed expansion height H/H0 (H is the bed height under operating conditions, H0 is the static bed height) and the pressure drop per unit static bed height ΔP/H0 were used as characteristic parameters. The effects of the gas-phase Reynolds number ReG and the liquid-phase Reynolds number ReL, both based on the column’s inner diameter as the common characteristic length, on the fluidization characteristics were systematically investigated, and the underlying laws of flow resistance and bed expansion were explained from the mechanism of gas–liquid two-phase interaction. The gas-phase Reynolds number ReG is calculated based on the superficial gas velocity and gas physical properties at the column inlet (bottom). The density and viscosity of the bulk phosphoric acid phase are adopted for ReL calculation. Since most of the dosed active SiO2 reacts with HF and is removed as gaseous SiF4, the residual dissolved SiO2 in the product acid is only about 0.1 wt%, and its influence on liquid density and viscosity is less than 1%, which is negligible compared with the property fluctuations caused by changes in acid concentration and operating temperature.
Figure 3 compares the relative bed expansion height and bed pressure drop gradient as functions of gas-phase and liquid-phase Reynolds numbers.
Figure 3.
(a) Variations in relative bed expansion height under different liquid operating conditions; (b) Variations in relative bed expansion height under different gas operating conditions; (c) Variations in pressure drop gradient under different liquid operating conditions; (d) Variations in pressure drop gradient under different gas operating conditions.
As shown in Figure 3a, at a fixed gas-phase Reynolds number (ReG = 55,971), the relative bed expansion height H/H0 first increased and then decreased with an increasing liquid-phase Reynolds number ReL. In the lower-ReL range, increasing the liquid flow enhanced the drag on the spherical packing, continuously lifting the packing particles and increasing bed expansion. After ReL reached a critical value, excess liquid formed a thick liquid film in the packing voids. The adhesion and retardation effects of the liquid film inhibited the suspension and lifting of the spheres, while the liquid phase occupied effective space in the bed and weakened the lifting effect of the gas phase on the spheres, causing the relative expansion height to decrease. With increasing ReL, H/H0 increased from approximately 1.22 near ReL = 700 to a peak of 1.33 (ReL ≈ 1000–1200), then decreased to 1.24 (ReL = 1400). This indicates that an excessively large liquid-phase Reynolds number leads to deterioration of the flow state. Therefore, the ReL range studied in this work was 697–1162.
As shown in Figure 3b, three groups of liquid-phase Reynolds numbers (ReL = 697, 929, 1162) were selected for analysis. At a fixed liquid-phase Reynolds number, the relative bed expansion height H/H0 increased monotonically with an increasing gas-phase Reynolds number ReG. As the gas velocity increased, the drag of the gas flow on the packing spheres and the turbulent disturbance were enhanced, and the suspension height of the packing continuously increased. At the same ReG, a higher ReL corresponded to a larger bed expansion height, indicating that liquid flow also assisted packing suspension. In the high-ReL range, the difference between the two curves gradually decreased, indicating that gas-phase drag gradually became dominant and the contribution of the liquid phase was weakened. When ReG increased to 111 and 943, H/H0 reached 1.75 under the ReL = 697 condition. The spheres expanded too high and began to hit the upper support plate, and backmixing became more severe.
As shown in Figure 3c, at a fixed ReG = 55,971, the pressure drop gradient per unit bed height ΔP/H0 first increased and then decreased with increasing ReL. Under low-ReL conditions, as the liquid flow increased, the liquid holdup in the packing voids increased, the gas–liquid two-phase flow resistance increased, and the pressure drop gradient continuously rose. A peak value of ΔP/H0 = 4.42 kPa/m was reached near ReL = 1200. As the liquid flow continued to increase, the bed expansion height increased significantly, the distance between packing particles increased, the bed bulk density decreased, and the blocking effect of particles on the fluid weakened, offsetting the resistance increment caused by increased liquid holdup. Ultimately, the pressure drop gradient decreased, falling to approximately 4.30 kPa/m at ReL = 1400.
As shown in Figure 3d, under liquid-phase Reynolds numbers ReL = 697,929 and 1162, the bed pressure drop gradient ΔP/H0 increased monotonically overall with an increasing gas-phase Reynolds number ReG (for high-ReL conditions, the growth slowed at extremely high ReG). As the gas-phase Reynolds number increased, the gas velocity increased, and the friction resistance between the gas and particles and at the gas–liquid interface simultaneously increased, leading to a continuous increase in pressure drop. At the same ReG, a higher ReL resulted in greater bed liquid holdup, higher fluid resistance, and a larger pressure drop gradient. In the high ReG region, the slope of the curves decreased, indicating that after the bed was fully expanded, the packing moved vigorously and the growth rate of collision dissipation between particles slowed. For example, at ReG = 55,971, the corresponding ΔP/H0 values at ReL = 697, 929, 1162 were approximately 3.85, 4.05, and 4.40 kPa/m; at ReG = 93,286, the three data sets increased to 5.60, 5.80, and 5.90 kPa.
The bed expansion and pressure drop of a TBC are determined by the competition among gas-phase drag, liquid-phase drag, particle gravity, and liquid-film viscous resistance. At low liquid flow, increasing the liquid flow can assist the suspension of spheres, increasing the expansion height and flow resistance. After exceeding the critical liquid-phase Reynolds number, excess liquid changes the fluid structure in the bed, weakening the suspension ability of particles, and the pressure drop gradient decreases. Increasing the gas-phase Reynolds number always strengthens the lifting effect on the packing and flow friction; therefore, both expansion height and pressure drop increase with increasing ReG. From the perspective of process intensification, moderate bed expansion is beneficial for increasing the gas–liquid contact area and surface renewal frequency. However, excessive expansion causes particle impact on the retaining screen, intensified axial backmixing, and a rapid increase in pressure drop. Therefore, a suitable operating range exists.
4.3. Mass-Transfer Characteristics
The reported HTU and Sh correlations characterize the water-evaporation step, which is gas-film-controlled. The fluorine removal is a reaction–mass-transfer coupled process: the liquid-phase reactions H2SiF6 → SiF4↑ + 2HF and 4HF + SiO2 → SiF4↑ + 2H2O generate volatile SiF4, while gas-phase stripping maintains a low SiF4 partial pressure. Owing to the high volatility of SiF4, the fluorine side is also governed mainly by the gas film, and the gas-phase turbulence (ReG) plays the dominant role, in qualitative agreement with the evaporation system. A quantitative fluorine-side mass-transfer coefficient cannot be obtained from the evaporation correlation; it requires the axial gas-phase SiF4 concentration profile, which is left for future work.
Figure 4a shows the variation in HTU with the gas-phase Reynolds number ReG under different liquid-phase Reynolds numbers ReL. For the ReL = 697 condition, HTU decreased monotonically with an increasing gas-phase Reynolds number: when ReG increased from 55,971 to 111,943, HTU decreased from approximately 1.54 m to 1.03 m. A smaller HTU represents a lower required mass-transfer contact height and a higher mass-transfer rate. This variation is consistent with the typical behavior of gas-film-controlled mass transfer. For the two higher liquid-phase Reynolds number conditions, ReL = 929 and ReL = 1162, increasing the gas-phase Reynolds number intensified particle expansion and increased the expanded bed height. Due to the upper bed limit constraint (to prevent particles from hitting the top support plate), the maximum ReG for these two conditions could only be increased to 93,286. Comparing the three curves, at the same ReG, a higher liquid-phase Reynolds number gave a lower HTU, indicating that increasing the liquid flow also favors mass-transfer intensification.
Figure 4.
(a) Variations in the height of a transfer unit in the TBC under different gas operating conditions; (b) Variations in the height of a transfer unit in the TBC under different liquid operating conditions.
Figure 4b fixes the gas-phase Reynolds number at ReG = 55,971 and shows the evolution of HTU with the liquid-phase Reynolds number ReL. HTU first decreased and then slightly increased with increasing ReL: as ReL increased from 700 to 1162, the bed wetted area continuously increased, the interfacial mass-transfer area expanded, mass transfer was intensified, and HTU decreased from 1.54 m to a minimum of 1.34 m. When ReL continued to increase beyond 1162, excess liquid caused droplet coalescence and deteriorated liquid dispersion, reducing the effective mass-transfer interfacial area and causing a slight increase in HTU.
Figure 5 shows the variation in the evaporation Sherwood number Sh with gas-phase Reynolds numbers ReG under different liquid-phase Reynolds numbers. Sh = kGdp/DG, where dp = 0.038 m is the sphere diameter and DG is the gas-phase molecular diffusivity. The effective specific surface area is obtained by counting the spheres (Ns = 8436) loaded in the bed: the total external surface area is As = Nsπdp2, and a = As/(ΩH); under the static state this gives a0 = As/(ΩH0), so that a = a0H0/H in the expanded bed. Since the process is gas-film-controlled, KG ≈ kG and KGa = ShDGa/dp; substituting into HTU = Gm/(KGaΩ) closes the mass-transfer framework. Overall, Sh increased approximately linearly with increasing ReG. As the gas-phase turbulence increased, the gas-phase mass-transfer boundary layer became thinner, and the evaporation mass-transfer capacity was enhanced. At the same ReG, when ReL increased from 929 to 1162, the increase in Sherwood number was limited, and the effect of liquid-phase Reynolds numbers on Sh was weaker than that of gas-phase Reynolds numbers, further confirming that the evaporation system is controlled by gas-film mass transfer.
Figure 5.
Variations in the Sherwood number for mass transfer in the TBC under different gas–liquid operating conditions.
In addition to mass-transfer performance, the TBC’s anti-fouling performance was preliminarily verified industrially. After 72 h of continuous stable operation, shutdown inspection showed no obvious blockage, and bed pressure drop showed no upward trend. This test only confirms short-term stability, not long-term scaling resistance. Mechanistically, the TBC’s anti-scaling advantage arises from continuous fluidization and frequent collisions of packing spheres: under turbulent fluidization, inter-particle collisions generate continuous shear on sphere surfaces, timely peeling off incipient scale—unlike static packed towers, where scale accumulates on fixed surfaces. Longer-term industrial monitoring is ongoing, and long-term performance will be reported subsequently.
To quantitatively assess the mass-transfer intensification of the proposed TBC for high-viscosity WPA, the HTU and Sherwood number results are compared with conventional stripping equipment and low-viscosity TBC systems. For high-viscosity mineral acid stripping, conventional random packed columns yield gas-phase HTU of 2.0–4.0 m and sieve plate columns 1.8–3.0 m [33], limited by poor interfacial renewal and severe fouling on static surfaces. In contrast, the present TBC achieves HTU of 0.9–1.6 m, a 40–60% reduction, benefiting from continuous fluidization, frequent particle collisions, enhanced interfacial renewal and inherent self-cleaning ability. Similar superiority of fluidized contactors over packed beds was reported by Ilea et al. [18] for CO2 absorption. Regarding viscosity effects, the HTU in this work is 40–60% higher than values reported for low-viscosity TBC systems [22,34], as elevated phosphoric acid viscosity thickens the liquid-side boundary layer and reduces surface renewal. Even so, the TBC still outperforms conventional static equipment for high-viscosity feeds. Dimensionlessly, the ReG exponent in the Sh correlation (1.5753) is far larger than the ~0.6 from the classical Wakao–Funazkri fixed-bed correlation [35], confirming that intense turbulence induced by fluidized spheres dominates the mass-transfer intensification.
4.4. Mass-Transfer Correlations
For engineering design applications, based on the experimental data and using a nonlinear iterative optimization method, a power-law correlation between the evaporation HTU and gas-phase and liquid-phase Reynolds numbers was established:
where HTU is the height of a transfer unit, in m; ReG is the gas-phase Reynolds number; and ReL is the liquid-phase Reynolds number. The applicable range of the correlation is: 5.6 × 104 ≤ ReG ≤ 1.12 × 105, 697 ≤ ReL ≤ 1162.
HTU = 673.98 × ReG−0.345 × ReL−0.353
A mass-transfer correlation was constructed using the Sherwood number, Reynolds number, and Schmidt number. The experimental data were fitted by multiple regression in the form Sh = AReGB ReLCSc1/3. Considering that the Schmidt number remained constant in this experimental system and referring to classical empirical gas–liquid mass-transfer correlations, the Schmidt number exponent was fixed at 1/3. The regression yielded:
Sh = 9.95 × 10−8 × ReG1.5753 × ReL0.2489 × Sc1/3
The exponent of the gas-phase Reynolds number is significantly larger than that of the liquid-phase Reynolds number, indicating that the mass-transfer process in the expanded bed is gas-film-controlled. The Sherwood number increases superlinearly with the gas-phase Reynolds number. This is because increasing the gas velocity significantly intensifies turbulent disturbance at the gas–liquid interface, thins the mass-transfer boundary layer, and greatly enhances the mass-transfer rate, consistent with the physical law of gas-phase turbulence-controlled mass transfer in gas–liquid two-phase flows. The liquid phase provides only limited turbulence near the interface. In a gas-phase-dominated mass-transfer system, the influence of the liquid-phase Reynolds number is weakened, consistent with the behavior of conventional gas–liquid mass-transfer equipment such as falling-film and bubble columns. The 1/3 Schmidt number exponent in Equation (9) was not independently fitted to this work’s data. The gas is mainly air with minor water vapor, and narrow temperature/pressure fluctuations keep Sc stable at ~0.622; without Sc variation, its exponent cannot be regressed. The 1/3 exponent is thus inherited from classical correlations (e.g., Ranz–Marshall), with Sc effects absorbed into the pre-factor. Its universality requires future verification with different Sc data.
Figure 6 compares experimental values with correlation-calculated values. The black solid line is the ideal reference line (Y = X) representing perfect agreement between predicted and experimental values; the two red dashed lines are the ±10% relative error boundaries; the gray filled region is the corresponding error interval; and each blue circle represents an independent experimental data point. This comparison intuitively quantifies the prediction performance of the established Sherwood number correlation Sh = AReGBReLCSc1/3. The data points are distributed near the 45° diagonal, indicating that the correlation has good prediction accuracy. Statistical tests of the HTU correlation regression results show that the model coefficient of determination R2 = 0.7301 and the root-mean-square error RMSE = 0.0807 m, indicating that the correlation can reasonably reflect the variation in HTU with gas- and liquid-phase Reynolds numbers and can be used for engineering calculations and process simulation under these operating conditions. The relative deviation from experimental data is within ±15%. The coefficient of determination of the Sh correlation is R2 = 0.9922, indicating high fitting accuracy. In this set of experiments, Sc = 0.622 was constant; therefore, Sc1/3 in the model was pre-specified according to the classical form of mass-transfer theory and was not obtained by regression fitting. If experimental data at different Sc become available in the future, the rationality of this exponent can be further verified. All experimental data points are closely distributed on both sides of the ideal (Y = X) reference line, indicating extremely high agreement between correlation predictions and experimental measurements. Statistical results show that the coefficient of determination R2 of the correlation reaches 0.9922, indicating that 99.22% of the variation in the Sherwood number can be explained by the three independent variables: the gas-phase Reynolds number, liquid-phase Reynolds number, and Schmidt number. The adjusted coefficient of determination R2 is 0.9908, further confirming that the model does not exhibit overfitting after introducing two hydrodynamic parameters and maintains excellent generalization ability. All data points fall completely within the ±10% relative error band. This error range is a generally accepted qualified accuracy threshold for correlations in the mass-transfer engineering field. Along the column height, the gas composition and physical properties change slightly due to water evaporation and SiF4 stripping. The water vapor mole fraction increases by about 8–10 percentage points from bottom to top, corresponding to a gas density variation of approximately 10% and a gas viscosity variation of less than 5%. The variation in ReG caused by gas property change along the column is within the error band of the correlations (±15% for HTU, ±10% for Sh). As SiF4 concentration in the gas phase is at the ppm level, its influence on gas physical properties can be completely ignored. Calculation shows that the average relative error of the correlation is 2.89%, and the maximum relative error under all operating conditions is only 5.95%. Over the entire range of Sherwood number values, the data points are symmetrically and uniformly distributed around the ideal fitting line, without systematic overall overestimation or underestimation bias, indicating that the correlation has good applicability and stability over the entire range of gas- and liquid-phase flow velocities investigated in this study. The good fitting performance also verifies the physical rationality of the correlation structure. The Sherwood number depends more strongly on the gas-phase Reynolds number, consistent with the mechanism of turbulence-controlled interfacial mass transfer in a gas-continuous system: increasing the gas velocity significantly intensifies turbulent disturbance at the gas–liquid interface and thins the mass-transfer boundary layer, which is the dominant factor enhancing the mass-transfer process. The small exponent of the liquid-phase Reynolds number is consistent with the limited contribution of liquid-side turbulence to interfacial mass transfer under the flow conditions of this experiment. The classical Sc1/3 form inherited from convective mass-transfer theory was also verified under the constant Schmidt number condition of this study through stable prediction accuracy.
Figure 6.
Comparison between experimental values and correlation-calculated values.
5. Conclusions
In summary, within a closed-loop tail-gas recycling framework, an integrated turbulent bed contactor (TBC) process was proposed and industrially validated for simultaneous air-stripping concentration and deep defluorination of wet-process phosphoric acid (WPA). The circulating gas serves as a mass carrier, heat carrier, and interfacial-renewal/intensification medium, creating a triple “carrier–interface–intensification” effect. Under excess SiO2, fluorine species—mainly H2SiF6, HF, and fluoride complexes—are directionally converted to volatile SiF4 via H2SiF6 decomposition and the HF–SiO2 reaction (2H2SiF6 + SiO2 → 3SiF4↑ + 2H2O), thereby avoiding HF accumulation and suppressing nonvolatile metal–fluoride complexes while maintaining acid fluidity. In a Φ0.62 m × 9 m industrial demonstration unit packed with three layers of hollow polypropylene spheres (static height 1.5 m), crude hemihydrate WPA (~40.5 wt% P2O5, ~1.15 wt% F) was upgraded in one step at atmospheric pressure to industrial-grade acid containing 58.1 wt% P2O5 and 0.08 wt% F; the P2O5/F mass ratio increased from ~35 to >726, and the defluorination efficiency reached 92–94%. Steam consumption was 0.732 t/t P2O5, 15.1% lower than the 0.862 t/t P2O5 for vacuum stripping, with a lower maximum operating temperature. Hydrodynamically, H/H0 increased monotonically with ReG and first increased then decreased with ReL (peak ~1.33), whereas ΔP/H0 increased overall with ReG and first increased then decreased with ReL (peak 4.42 kPa/m), indicating that ReG governs fluidization intensity while ReL regulates system resistance. HTU ranged from 0.9 to 1.6 m and decreased with increasing liquid-to-gas ratio; low spray density exhibited an optimal gas velocity, while medium/high spray densities favored high gas velocity to reduce HTU. Sh increased approximately linearly with ReG but depended weakly on ReL, confirming gas-film-controlled evaporation. Empirical correlations were established as HTU = 673.98 × ReG−0.345 × ReL−0.353 (R2 = 0.7301, RMSE = 0.0807 m, ±15%) and Sh = 9.95 × 10−8 × ReG1.5753 × ReL0.2489 × Sc1/3 (R2 = 0.9922, average relative error 2.89%, maximum 5.95%, within ±10%), applicable for 5.6 × 104 ≤ ReG ≤ 1.12 × 105 and 697 ≤ ReL ≤ 1162. The TBC packing exhibited self-cleaning and anti-clogging behavior, with no blockage after 72 h of continuous operation. This single-column integrated process enables simultaneous concentration and deep defluorination, providing reliable scale-up data for green WPA refining.
Funding
This research was funded by the Sichuan Provincial Science and Technology Support Program (Grant No. 2023ZHJY0015).
Data Availability Statement
Data are contained within the article.
Acknowledgments
The authors acknowledge Jiacai Wang, Yongqiang Ma, Haibing Yuan, Pan Luo from the Chanheng Group for the help with industrial data collection.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Li, J.; Peng, Y.F.; Zhu, J.H. Principle and application of closed-loop recycling of tail gas in process industries (I): Wet-process phosphoric acid. CIESC J. 2021, 72, 5257–5264. [Google Scholar]
- Wang, W.; Fan, D.; Chen, D.L.; Huang, Z. Research progress on defluorination processes and fluorine resource recovery from wet-process phosphoric acid. Eco-Ind. Sci. Phosphorus-Fluor. Eng. 2025, 40, 31–40. [Google Scholar]
- Huang, Z.; He, B.B.; Zhang, X.F. Review on systematic synergy and integrated optimization of fluorine resource recovery in phosphorus-chemical systems. Eco-Ind. Sci. Phosphorus-Fluor. Eng. 2025, 40, 70. [Google Scholar]
- Ai, P.P.; Peng, Z.K.; Liu, C.L.; Chen, Y.X.; Weng, X.Q.; Li, H.Q. Research status and development direction of defluorination technology of wet-process phosphoric acid. Hydrometall. China 2024, 43, 9–14. [Google Scholar]
- He, B.; Zhu, Y.; Zu, Y.; Nie, Y.; Mei, Y. Designing an efficient fluorine recovery strategy for wet-process phosphoric acid purification by disclosing competitive complexation behavior between fluorine species and metal cations. Sep. Purif. Technol. 2023, 320, 124122. [Google Scholar] [CrossRef] [Scilit]
- He, B.B.; Zhou, Q.B.; Zhang, H. Study on stripping defluorination technology of wet-process phosphoric acid. Inorg. Chem. Ind. 2016, 48, 61–64. [Google Scholar]
- Jradi, R.; Marvillet, C.; Jeday, M. Analysis and estimation of cross-flow heat-exchanger fouling in phosphoric-acid concentration plant using response-surface methodology and artificial neural network. Sci. Rep. 2022, 12, 20437. [Google Scholar] [CrossRef] [Scilit]
- Bagoun, R.; EL Khouakhi, M.; Elhoussaine, O.; El Asri, M. Critical fouling resistance in heat-exchanger energy efficiency in phosphoric-acid concentration: An industrial-plant Aspen-Plus simulation-based approach. Moroc. J. Chem. 2025, 13, 45–54. [Google Scholar]
- He, B.B.; Zhang, Y.; Mei, Y.M. Investigation on the fluorine recovery mechanism by air stripping for synthetic and industrial wet-process phosphoric acid. Carbon Lett. 2023, 33, 2313–2325. [Google Scholar] [CrossRef] [Scilit]
- Chen, Y.; Garcia-Meza, J.V.; Zhou, B. Efficient recovery of fluorine from wet-process phosphoric acid using silicon powder as a new and eco-friendly reagent. Sep. Purif. Technol. 2024, 337, 125471. [Google Scholar] [CrossRef] [Scilit]
- Xu, H.C.; Sun, Z.; Yu, J.G. Mechanism of extracting and separating fluoride in phosphoric acid by TBP system. J. East China Univ. Sci. Technol. (Nat. Sci. Ed.) 2020, 46, 589–597. [Google Scholar]
- Li, J.; Wang, J.C.; Ma, Y.Q.; Yuan, H.B.; Jian, L.M.; Jiang, J.C.; Zhu, J.H. Thermodynamic analysis and engineering practice of high-efficient recycle of fluorine contained in tail gas from wet-process phosphoric acid plant. CIESC J. 2025, 76, 1484–1492. [Google Scholar]
- Ullah, A.; Amanat, A.; Imran, M.; Zaman, M. Effect of turbulence modeling on hydrodynamics of a turbulent contact absorber. Chem. Eng. Process.-Process Intensif. 2020, 148, 108101. [Google Scholar]
- Bensebia, B.; Chaouche, F.Z.; Bensebia, O.; Bouafia, H. Bed expansion in turbulent bed contactor: Experiments and prediction. Chem. Ind. Chem. Eng. Q. 2024, 30, 47–58. [Google Scholar] [CrossRef] [Scilit]
- Dou, R.G.; Wang, W.H.; Zhu, J.H. Study on critical fluidization velocity of a turbulent-bed contactor for tail-gas deammoniation. Chem. Eng. Equip. 2014, 6, 24–26. [Google Scholar]
- Muhammad, M.; Zaman, M.; Li, F.; Ullah, A. CFD simulation of liquid holdup in a three-phase countercurrent turbulent contact absorber. Powder Technol. 2023, 416, 118203. [Google Scholar] [CrossRef] [Scilit]
- Gillani, S.S.J.; Ullah, A.; Zaman, M.; Chugtai, I.R.; Inayat, M.H. Counter-current three-phase fluidization in a turbulent contact absorber: A CFD simulation. Particuology 2017, 33, 51–67. [Google Scholar] [CrossRef] [Scilit]
- Ilea, F.M.; Cormos, A.M.; Dragan, S.; Cormos, C.C. Assessment of turbulent contact absorber hydrodynamics with application in carbon capture. Chem. Eng. J. 2022, 444, 137674. [Google Scholar] [CrossRef] [Scilit]
- Leng, H.; Liu, Y.C.; Yan, Y.H.; Zhang, M.; Zhou, H.B. Study on enhanced recovery of fluoride escaping from wet-process phosphoric acid. Eco-Ind. Sci. Phosphorus-Fluor. Eng. 2025, 40, 16–21. [Google Scholar]
- Abukhalfieh, H. Hydrodynamics of turbulent-bed contactor with non-Newtonian liquids. Can. J. Chem. Eng. 2015, 93, 1448–1456. [Google Scholar] [CrossRef] [Scilit]
- Bruce, A.E.R.; Vinay, W.A.; Sai, P.S.T.; Krishnaiah, K. Estimation of liquid-phase mixing due to solids in a turbulent-bed contactor. Chem. Eng. Sci. 2006, 61, 3403–3408. [Google Scholar] [CrossRef] [Scilit]
- Guerriere, R.A.; Fayed, M.E. Mass transfer in a turbulent-bed contactor. Chem. Eng. Res. Des. 1995, 73, 347–354. [Google Scholar] [CrossRef] [Scilit]
- Wang, W.H.; Dou, R.G.; Xia, S.L.; Zhu, J.H. Mass-transfer coefficient of low-concentration NH3 tail-gas absorption in a turbulent-bed contactor. Chem. Eng. Des. 2014, 44, 43–46. [Google Scholar]
- Bruce, A.E.R.; Sai, P.S.T.; Krishnaiah, K. Liquid-phase mixing in turbulent bed contactor. Chem. Eng. Sci. 2003, 58, 3453–3463. [Google Scholar] [CrossRef] [Scilit]
- Ilea, F.M.; Cormos, C.C. Techno-economic implications of three-phase fluidized-bed absorption column applied to power generation for an intensified carbon-capture process. Energy Convers. Manag. 2024, 315, 118790. [Google Scholar]
- Zuchrillah, D.R.; Pudjiastuti, L.; Zalsabila, A.; Pratama, R.A.; Setyawan, H. Effect of additional concentration of ATMP inhibitor on the formation of 40% phosphoric acid scale. Eng. Chem. 2025, 26, 112–118. [Google Scholar] [CrossRef] [Scilit]
- Wang, X.H.; Sun, W.Z. Research progress on fluorine-recovery technology in wet-process phosphoric acid. Inorg. Chem. Ind. 2020, 52, 25–29. [Google Scholar]
- He, B.B.; Zhu, Y.; Zu, Y.; Nie, Y.; Mei, Y. Efficient and cost-effective fluorine recovery from liquid-phase wet-process phosphoric acid via two-step precipitation method. Sep. Purif. Technol. 2023, 325, 124687. [Google Scholar] [CrossRef] [Scilit]
- Bichri, A.; Jbari, Y.; Abderafi, S. Multi-objective optimization of phosphoric acid production unit, to minimize P2O5 losses. Comput. Chem. Eng. 2025, 191, 109477. [Google Scholar] [CrossRef] [Scilit]
- Teng, B.; Mekdimu, M.D.; Wang, C.; Li, Y. Comprehensive review of modified clay minerals for phosphate management and future prospects. J. Clean. Prod. 2024, 447, 141425. [Google Scholar] [CrossRef] [Scilit]
- Standard’s GB/T 1871.1-1995; Phosphate Rock and Concentrate—Determination of Phosphorus Pentoxide Content—Quinoline Phosphomolybdate Gravimetric and Volumetric Methods. State Bureau of Technical Supervision: Beijing, China, 1995.
- Standard’s GB/T 1872-1995; Phosphate Rock and Concentrate—Determination of Fluorine Content—Specific Ion Electrode Method. State Bureau of Technical Supervision: Beijing, China, 1995.
- Gómez-Díaz, L.M.; Navaza, J.M.; Sanjurjo, B. A Review on Gas-Liquid Mass Transfer Coefficients in Packed-Bed Columns. Separations 2018, 5, 43. [Google Scholar]
- Roohian, A.; Jahanmiri, A.; Rahimpour, M.R. Comparative Modeling and Analysis of the Mass Transfer Coefficient in a Turbulent Bed Contactor using Artificial Neural Network and Adaptive Neuro-Fuzzy Inference Systems. Sep. Sci. Technol. 2014, 49, 762–771. [Google Scholar] [CrossRef] [Scilit]
- Wakao, N.; Funazkri, T. Effect of fluid dispersion coefficients on particle-to-fluid mass transfer coefficients in packed beds. Chem. Eng. Sci. 1978, 33, 1375–1384. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.