Abstract
This study presents a computational analysis of degradation caused by cavitation and hydro-abrasive erosion in a low-head axial microturbine ( ), incorporating strategic air injection as a passive mitigation technique. Using Computational Fluid Dynamics (CFD) within ANSYS CFX 2025 R2, the study investigates hydrodynamic performance and the spatial distribution of surface wear across the runner blades. The turbine geometry was developed from aerofoil profiles mapped onto cylindrical coordinates, using a structured three-dimensional mesh with localized refinement to ensure grid independence. Physical modeling employed the Shear Stress Transport (SST) turbulence model, with cavitation dynamics governed by the Rayleigh–Plesset equation and sediment transport modeled using a Lagrangian framework incorporating the Finnie erosion model. The numerical framework showed good agreement with reference characteristic curves, confirming its predictive accuracy. The results indicate that vapor cavities form predominantly on the suction side, whereas solid particle erosion highly concentrated on the pressure side of the blades, where the outer of the span accounts for over of the total erosion intensity. Parametric assessments of controlled air injection revealed a highly non-linear mitigation response, identifying IAVF 2 as the optimal air-injection case. This configuration reduced integrated erosion by and maximum localized erosion by . In contrast, excessive air volumes accelerated material removal due to localized flow distortion. The findings indicate that carefully controlled air injection is a viable strategy for extending the operational lifespan of small-scale hydropower assets.