Effect of Regenerative Evaporative Cycle on Performance and NOx Formation of a Micro Gas Turbine

,
,
,
,
,
,
and
1
Academic Unit of Cabo de Santo Agostinho, Federal Rural University of Pernambuco, 163rd Street, 300, Garapu, Recife 545.18-430, PE, Brazil
2
Department of Mechanical Engineering, Federal University of Pernambuco, Arquitetura Ave., no number, Cidade Universitária, Recife 507.40-550, PE, Brazil
3
Academic Department of Higher Education Programs, Federal Institute of Education, Science, and Technology of Pernambuco, Professor Luiz Freire Avenue, 500, Cidade Universitária, Recife 507.40-545, PE, Brazil
4
Department of Nuclear Engineering, Higher Institute of Technologies and Applied Sciences, University of Havana, Quinta de los Molinos, Salvador Allende Ave., Plaza de la Revolución, Havana 19390, Cuba

Abstract

Micro gas turbines are small-scale systems based on the Brayton cycle and represent a viable solution for distributed generation. However, the main limitation to extending their application range is the cycle efficiency. Numerical and experimental analyses of power plants are important for evaluating the energy performance of different cycle configurations. Another issue is the formation of pollutants, including nitrogen oxide emissions. The humidified gas turbine cycle is one alternative to address these problems. Among wet cycles, the regenerative evaporative cycle offers a means to improve gas turbine efficiency. However, this configuration is less commonly discussed in the literature, which focuses more on steam injection cycles. Therefore, this paper presents an energy, exergetic, and nitrogen oxide formation analysis of an evaporative regenerative cycle for a 30 kW micro gas turbine across the gas turbine load range to define the most suitable operational system regime. The novelty of this study lies in an integrated assessment that simultaneously covers the operation of the micro gas turbine at full and part load under different conditions of water injection into the evaporator. The analyses conducted show that, for the micro turbine operating at full load, the benefits in terms of energy and pollutant formation are positive for all fractions of injected water. However, decreases in cycle performance are reported at power outputs below 19 kW compared with the dry cycle. Although nitrogen oxide formation decreases with increasing water injection, the reduction is less pronounced at lower microturbine power levels.