Abstract
The complex and nonlinear load characteristics of Hall thrusters remain a key challenge in the design of propulsion power-supply output stages. In existing power-supply simulations for electric propulsion systems, the Hall thruster is often simplified as a fixed impedance or a prescribed current source, which makes it difficult to capture the time-synchronized interaction during simulation between the power-supply output stage and the thruster discharge process. To address this issue, this study encapsulates a one-dimensional discharge model as an externally callable thruster slave and proposes a HallThruster.jl–Simulink–Saber co-simulation method. The proposed method enables synchronized bidirectional exchange between the power-port voltage and the thruster discharge current . The results show that the discharge current under the co-simulation condition exhibits a sustained low-frequency response at approximately 15.0 kHz. Compared with a fixed-voltage standalone simulation, the co-simulation preserves the same principal oscillation band and overall internal-field structures, while small but observable differences remain in instantaneous phase, local waveform shape, harmonic amplitudes, and high-gradient regions of the internal fields. The proposed method provides a computational framework for investigating dynamically coupled port behavior between a Hall thruster and a representative power-supply output stage.
1. Introduction
Hall thrusters have been widely used in station keeping, orbit transfer, deep-space exploration, and low-Earth-orbit satellite constellations because of their high specific impulse, long lifetime, and high propellant utilization efficiency [1,2,3]. As the on-orbit operating time and the number of start–stop cycles of electric propulsion systems continue to increase, system design has gradually shifted from the performance of an individual thruster to the coordinated matching among the thruster, the power processing unit (PPU), and the control system. As the core unit for energy conversion and control in an electric propulsion system, the PPU must provide multiple power supplies for anode discharge, magnetic excitation, cathode heating, ignition, and other subsystems [3,4,5,6]. In particular, the anode power-supply output stage is directly connected to the thruster discharge channel and provides the anode voltage for the thruster. It is also subjected to output ripple and device stress induced by discharge-current oscillations and transient load variations. Therefore, it is a critical part of propulsion power-supply reliability design.
In current PPU design practice, the thruster load is often represented as a fixed resistor, an equivalent impedance, or a prescribed current source. These approaches are convenient for analyzing power topology, control loops, output filters, and device stress, but they cannot represent the real-time feedback of the thruster discharge state to the power-supply output stage. In fact, a Hall thruster is not a constant-impedance load. Neutral transport, ionization, electron transport, potential reconstruction, and ion acceleration inside the thruster jointly affect the discharge current and can generate periodic low-frequency oscillations [7,8,9,10,11,12,13,14,15,16]. Therefore, if a fixed impedance or an offline current waveform is used as the thruster load in the analysis of a propulsion power-supply output stage, the time-synchronized interaction during simulation between the thruster discharge process and the power port may not be captured, and the output-voltage ripple, load fluctuation, and subsequent device stress may be underestimated.
Previous Hall-thruster studies have mainly focused on discharge physics, low-frequency oscillation mechanisms, and internal plasma evolution. Choueiri systematically reviewed plasma oscillations in Hall thrusters [7]. Boeuf and Garrigues modeled the formation of low-frequency oscillations in stationary plasma thrusters [8]. Lafleur et al. analyzed the origin and stabilization of the breathing mode using 0D and 1D models [9]. Dale and Jorns studied the time-resolved variation of plasma parameters during the breathing mode [10]. Chapurin et al. discussed the formation mechanism of low-frequency instabilities from the perspectives of ionization-oscillation models and fluid/hybrid simulations [11,12]. Petronio et al. further investigated the development of the breathing mode using hybrid simulations [13]. Leporini et al. studied the onset and development of the breathing mode from the perspectives of electron-mobility perturbations and unstable 0D ionization models [14,15]. In contrast, PPU-related studies have mainly focused on power architecture, power density, and engineering implementation. Fang et al. proposed a PPU system architecture based on a high-frequency AC bus [5]. Goebel and Katz systematically described the power-supply relationships among the thruster, cathode, and PPU in electric propulsion systems [3]. These studies have advanced both Hall-thruster discharge modeling and PPU engineering design. However, in most simulations, the two parts are still connected through simplified boundaries or equivalent loads: the thruster side usually adopts a prescribed voltage boundary, whereas the power-supply side often treats the thruster as a fixed impedance or a prescribed current source. This treatment facilitates separate analysis of the thruster and the power supply, but it is difficult to describe the time-synchronized interaction during simulation between the power-supply output stage and the thruster discharge process.
In recent years, the influence of power-circuit parameters on Hall-thruster discharge dynamics has attracted increasing attention. Brieda et al. showed that the power-supply model can affect simulated discharge-voltage oscillations of Hall thrusters [17]. Simmonds et al. investigated the discharge response of a Hall thruster under modulated voltage and its relationship with the breathing mode [18]. Jovel et al. carried out impedance characterization of Hall thrusters, providing a basis for understanding the dynamic thruster load from the power-supply side [19]. Jorns et al. modeled mode transitions in a magnetically shielded Hall thruster, further indicating that discharge dynamics are closely related to external boundary conditions [20]. These studies demonstrate that the PPU and the Hall thruster do not form a simple one-way power-supply relationship. The power-supply output stage can affect thruster discharge parameters, while the thruster discharge state also feeds back to the power port through dynamic current. Therefore, an online coupling method capable of synchronously exchanging port voltage and discharge current during simulation is required.
Based on these issues, this paper establishes a port-level online co-simulation model for the dynamic load characteristics of Hall thrusters using HallThruster.jl [21], Simulink [22], and Saber [23]. In this model, the open-source one-dimensional Hall thruster discharge solver is encapsulated as a physical load module that can be driven in a time-synchronized manner by the power-supply output stage. Through the Simulink interface, the output-port voltage from the Saber power-supply model and the discharge current from HallThruster.jl are synchronously exchanged, enabling bidirectional time-domain coupling between the power-supply response and the internal discharge state of the thruster. During the simulation, in addition to the port voltage, discharge current, and frequency-domain response, internal thruster parameters such as electron density, neutral density, electric potential, axial electric field, and electron temperature can also be recorded. These results can be used to examine whether variations in the power-supply port voltage affect the internal discharge process of the thruster. The proposed method provides an extensible co-simulation platform for studying the dynamic coupling between the power supply and the Hall thruster. The present work focuses on establishing and verifying the port-level coupling method; detailed component-stress, controller-design, and reliability analyses require a more complete PPU model and are reserved for future work.
2. Materials and Methods
This section introduces the model components and data-exchange strategy of the online co-simulation. The Saber side is used to build the propulsion power-supply output-stage model and to describe the transient responses of the power-port voltage, current, and output filter network. The HallThruster.jl side is used to calculate the one-dimensional Hall-thruster discharge process and to obtain the internal plasma state and discharge current under the current discharge boundary. Simulink serves as the interface layer and organizes the data transfer and synchronous calls between Saber and Julia.
2.1. Hall-Thruster Fluid Model
In propulsion power-supply output-stage simulation, the choice of the load model directly affects the calculated port voltage, current ripple, and component stress. For a conventional resistor, the port relationship is mainly determined by fixed parameters. For example, a resistive load satisfies an approximately linear voltage–current relation . Under a given operating condition, the parameters of this type of load usually remain unchanged, and the power-supply side can describe its port response using a fixed impedance or simple differential equations.
A Hall thruster is different. Although the anode port of the thruster appears as a voltage-current relationship at the circuit level, its discharge current is not determined solely by the instantaneous port voltage. Instead, it is jointly determined by the neutral density, electron density, potential distribution, axial electric field, electron temperature, and ionization source term in the discharge channel. In other words, the propulsion power supply does not see a fixed impedance element but a nonlinear dynamic load formed by the real-time evolution of the plasma state. A change in the port voltage modifies the electric field and electron-energy state in the channel and then affects the ionization rate and charged-particle transport. Conversely, variations in particle density and potential structure change the discharge current and feed back to the power-supply output stage. Accordingly, the Hall thruster behaves as a time-varying and nonlinear load rather than a fixed impedance. Conventional representations retain only part of this interaction: a fixed resistor or prescribed current source does not account for the real-time evolution of the plasma state, whereas a fixed-voltage standalone thruster simulation does not allow the calculated discharge current to modify the power-supply boundary. In the present co-simulation, the Saber output voltage is applied as the instantaneous discharge boundary, and the resulting HallThruster.jl current is returned at each communication step, allowing the power-supply output and the internal plasma state to evolve within the same synchronized time-marching process.
This study uses the one-dimensional axial discharge model in HallThruster.jl to describe the main plasma processes inside the thruster. Along the axial direction, the model solves governing relations related to neutral transport, ion generation and acceleration, electron transport, potential distribution, and electron-energy evolution. The neutral continuity equation describes propellant supply and ionization depletion. The ion continuity equation and momentum relation describe ion generation and axial acceleration. The electron-transport relation describes electron mobility under magnetic-field confinement. The potential and axial electric field jointly determine the position of the main acceleration region. The electron-energy equation reflects the balance among electron heating, ionization loss, and wall loss. These internal variables jointly determine the discharge current at the current time.
To clarify the relationship between the port current and the internal state, the governing relations directly related to the formation of the dynamic load are listed below. Here, denotes the axial coordinate, is the electron density, is the neutral density, is the electron temperature, is the potential, is the axial electric field, is the discharge current, and is the ionization source term. The specific numerical discretization, boundary conditions, and transport closures follow the original implementation of HallThruster.jl.
To avoid ambiguity in the sign convention, the axial coordinate is defined from the anode toward the cathode/exit region. The electrostatic potential is denoted by , and the axial electric field is defined as
The ion and electron particle fluxes are defined as positive in the direction. The ion flux is , where is the ion density and is the axial ion velocity. The electron particle flux is denoted by . Under this convention, the discharge current through the channel cross-sectional area is written as
Here, is the elementary charge. The negative sign before accounts for the negative charge of electrons when the electron particle flux is defined in the positive axial direction.
The neutral continuity equation describes propellant injection and ionization depletion:
where is the neutral density, is the axial neutral velocity, and is the ionization source term. The ion continuity equation is
For the xenon-only case considered here, . The xenon single-ionization source term is evaluated as
where has units of , and are the electron and neutral-xenon number densities, respectively, and is the electron-impact ionization rate coefficient with units of . The coefficient is obtained by interpolating the tabulated electron-energy–rate-coefficient data in ionization_Xe_Xe+.dat. The listed xenon single-ionization energy is 12.13 eV, and the reaction-data source follows Dragnea et al. [24].
The one-dimensional ion momentum equation can be written in conservative form as
where is the ion pressure and is the ion mass. If multiple ion charge states are considered, the same form is applied to each charge state with the corresponding charge number.
Electron transport is described using the quasineutral drift–diffusion approximation. The axial electron particle flux can be expressed as
where is the electron density, is the electron pressure, and is the effective cross-field electron mobility. The mobility is written as
Here, is the electron mass, is the radial magnetic-field strength, is the electron cyclotron frequency, and is the Hall parameter. The total electron momentum-transfer collision frequency is
where is the classical collision frequency and is the anomalous collision frequency. For the default anomalous-transport closure used here, HallThruster.jl adopts the TwoZoneBohm model:
where inside the channel and downstream of the channel exit unless otherwise specified in the input file. is the channel length.
The electron-energy balance is written as
where is the electron internal-energy density; is the electron-energy flux; is the Joule heating term; and , , and are the ionization, wall, and collision loss terms, respectively. The detailed numerical discretization, boundary conditions, anomalous transport closure, wall-loss treatment, and initial condition follow the HallThruster.jl implementation used in this work and are summarized in Table 1.
Table 1.
Main parameters of the HallThruster.jl–Simulink–Saber co-simulation.
2.2. HallThruster.jl–Simulink–Saber Co-Simulation Method
Figure 1 shows the port-level online co-simulation structure adopted in this work. The Saber side represents a propulsion power-supply output stage and its port transients. Simulink serves as the interface organization layer and is responsible for S-Function calls and Transmission Control Protocol (TCP) data forwarding. The Julia side runs the HallThruster.jl thruster slave. Only two port variables are exchanged among the three components: Simulink–Saber sends to Julia, and Julia returns , which is determined by the current internal discharge state.
Figure 1.
Port-level co-simulation framework between the Simulink–Saber power-supply output stage and the Julia thruster slave. The component labels in the upper circuit use the following units: inductance in mH or μH, capacitance in μF or nF, and resistance in Ω.
The key feature of this structure is the synchronized feedback of port variables. At each interface instant, the Saber output stage receives returned by the thruster model from the previous communication step. The Julia thruster slave updates from the power-supply side with each communication step. Therefore, the port voltage, the internal thruster state, and the discharge current returned to the power-supply side are updated sequentially within the same time-marching process, forming an online closed loop of “port-voltage update of the discharge boundary—internal plasma-state advancement—diagnostic-current feedback to the output stage”.
The Saber circuit model retains the finite output impedance and filter network required for the output voltage to respond dynamically to the returned discharge current. Here, “closed-loop coupling” refers to the bidirectional numerical exchange between the Saber and HallThruster.jl models, rather than to a regulated voltage-control loop. The representative Saber power stage is operated using fixed gate pulses and does not include a closed-loop voltage compensator. With this treatment, the Saber side provides a non-ideal power-supply output, while the Julia-side thruster model updates the discharge state in real time and returns the dynamic load current.
In this work, the Saber-side model focuses on a representative propulsion power-supply output stage, which is sufficient for investigating the bidirectional port interaction between the power supply and the Hall thruster. Complete PPU functions, including closed-loop control, protection, and multi-output coordination, are beyond the scope of the present study and will be considered in future system-level investigations.
The representative Saber power stage consists of a four-switch full-bridge inverter, a high-frequency transformer, a full-bridge diode rectifier, and a two-stage output filter. The four IRF250 MOSFETs are driven by fixed-frequency phase-shifted voltage pulses with a period of 25 μs (40 kHz); a pulse width of 12 μs; and delays of 0, 5, 12.5, and 17.5 μs. The gate-pulse high level is 12 V, and the rise and fall times are both 0.1 μs. The transformer winding turns are N1 = 16 and N2 = 130. The rectified output is filtered by a 1 mH inductor and a 20 μF capacitor, followed by an 870 μH inductor with a parallel 200 Ω damping resistor and a 15 μF output capacitor. The present representative power stage uses fixed gate-pulse parameters and does not include a closed-loop voltage compensator or variable-duty modulation; therefore, no feedback-controller bandwidth is involved. The HallThruster.jl discharge current is applied online as the dynamic load through the Saber–Simulink interface. The main circuit and operating parameters of the representative Saber power-supply output stage are summarized in Table 2.
Table 2.
Main circuit and operating parameters of the representative Saber power-supply output stage.
The co-simulation adopts local TCP request–response communication. In the main case, the communication macro-step is consistent with the port recording interval, approximately 1 μs, whereas HallThruster.jl uses adaptive internal stepping with a configured maximum step of 5 ns. Within one communication macro-step, the power-port voltage is held by zero-order hold while the internal thruster state is advanced using smaller adaptive steps. The interface is therefore an explicitly synchronized sample-and-hold port coupling, and the returned current has at most one communication macro-step of response delay relative to the input voltage. This delay is much smaller than the low-frequency oscillation period considered in this work and does not affect dominant-frequency identification in the millisecond-scale windows used below.
This encapsulation preserves the traceability of the original HallThruster.jl model and diagnostic quantities while allowing it to serve as a physical load module callable by the power-supply side. The load current is calculated from the internal thruster state under the current discharge boundary. Each sampled port-voltage value is then used to advance the internal plasma state and determine the subsequent electron density, neutral density, potential, axial electric field, electron temperature, and discharge current.
The interface layer transmits only two port variables, and , to maintain a clear coupling boundary between the power-supply side and the thruster side. To improve long-term stability, the communication layer performs finite-value checks on the input voltage and returned current, preventing NaN, Inf, or other abnormal values from entering subsequent exchanges. The diagnostic outputs are divided into port quantities and internal quantities. The port time series include t, , and and are used for the analysis of mean current, peak-to-peak value, local peaks and troughs, and fast Fourier transform (FFT). The internal field quantities include , , , , and and are used to observe the spatiotemporal evolution of the ionization region, acceleration region, and electron-heating region during low-frequency cycles. Both types of data are saved using the same time base.
For the frequency-domain comparison, the co-simulation and fixed-voltage reference current signals were analyzed over the same 1.0–5.0 ms interval with a sampling interval of 1.0 μs. Each record contained 4000 samples. After removal of the mean value, a Hann window was applied, and no zero padding was used. The corresponding frequency-bin spacing was 0.25 kHz. As an independent time-domain estimate, local peaks were detected over the same interval using a three-point moving average only for peak identification, with a minimum peak separation of 50 μs. The peak–interval frequency was calculated as the reciprocal of the mean interval between consecutive valid peaks.
3. Results
Based on the online co-simulation method described above, this section analyzes the coupled response between the propulsion power-supply output stage and the Hall-thruster load. The port-current response and spectral characteristics of the main co-simulation case are first presented. A fixed-voltage reference, internal-field comparisons, and a resistive-load comparison are then used to evaluate the influence of online bidirectional coupling on the thruster discharge process and the power-supply output response.
3.1. Output Characteristics of the Hall Thruster Under Online Port Coupling
Figure 2 shows the discharge-current response of the 200-cell main co-simulation case over 0–10 ms. After the start-up transient, the current does not converge to a constant value but maintains periodic peaks and troughs in the subsequent time interval. The blue shaded region bounded by the dashed lines in Figure 2a denotes the 4–5 ms stable oscillation window, which is enlarged in Figure 2b. The FFT dominant peaks in the 1–5 ms and 5–10 ms windows are both located at approximately 15 kHz, indicating that this response is not a short-lived start-up disturbance. Table 3 summarizes the quantitative discharge-current metrics obtained over the different analysis windows. In the 1–5 ms window, the mean current is 4.95 A, the peak-to-peak value is 6.93 A, and the dominant frequency is 15.00 kHz. In the 5–10 ms window, the mean current is 4.95 A, the peak-to-peak value is 5.97 A, and the dominant frequency is 15.00 kHz. The similar mean values, standard deviations, and dominant frequencies in the two later windows indicate that the main case forms a sustained low-frequency dynamic load.
Figure 2.
Discharge-current response of the main co-simulation case over 0–10 ms, local oscillation window, and FFT comparison.
Table 3.
Discharge-current metrics in different time windows for the main co-simulation case.
Figure 2 also shows a start-up current peak of approximately 15.45 A at about 0.37 ms. This response occurs while the Saber output voltage is being established and the HallThruster.jl plasma state is being initialized. It is therefore interpreted as a coupled start-up/initialization transient rather than as part of the later sustained low-frequency oscillation. The transient decays before approximately 1 ms; consequently, the principal statistical and spectral metrics are evaluated in windows beginning at 1 ms.
To determine whether the online co-simulation merely reproduces the self-oscillation of the thruster under fixed-voltage simulation, this study compares the co-simulation and fixed-voltage simulation results in the 4.20–4.95 ms window. The reference uses a fixed discharge voltage of 245 V, selected to represent the late-time port-voltage level of the co-simulation. This window contains approximately eight low-frequency cycles and is suitable for comparing peaks, troughs, and phase.
Figure 3 shows sustained low-frequency periodic peaks under both boundary conditions, confirming that the principal oscillation is retained when the time-varying port boundary is replaced by a representative fixed-voltage boundary. The mean current and local peak-to-peak range are nearly identical, whereas the raw time-aligned curves exhibit a gradual phase offset and differences in cycle-scale spike shape. Table 4 quantifies the close statistical agreement. The fixed-voltage result therefore confirms that the oscillation is primarily associated with the thruster discharge dynamics, while the remaining phase and waveform differences indicate a modest modulation by the online power-supply boundary.
Figure 3.
Discharge-current comparison between the co-simulation and fixed-voltage simulation in a stable local window.
Table 4.
Local discharge-current metrics of the co-simulation and fixed-voltage simulation (4.20–4.95 ms).
Figure 4 further compares the above- and below-mean current stages under the two conditions. The above-mean stage is defined as the interval in which the current is higher than the local window mean, whereas the below-mean stage corresponds to the interval in which the current is lower than or equal to the mean. The above-mean time occupancies are 43.33% for the online co-simulation and 45.20% for the fixed-voltage reference, while the corresponding below-mean occupancies are 56.67% and 54.80%, respectively. The similar occupancy ratios indicate that the two cases retain comparable non-sinusoidal waveform asymmetry in the selected window.
Figure 4.
Comparison of above- and below-mean current time occupancy between the online co-simulation and fixed-voltage reference.
Figure 5 compares the discharge-current FFTs of the co-simulation and fixed-voltage reference cases over the 1–5 ms window using their common 1.0 μs time base. Both signals were mean-removed and processed using a Hann window. With N = 4000 samples, the effective record length is 4.000 ms and the frequency-bin spacing is 0.25 kHz. The dominant FFT bins are identified at 15.00 kHz for the online co-simulation and 14.75 kHz for the fixed-voltage reference. The corresponding vertical dashed lines in Figure 5 mark these two dominant FFT frequencies. The corresponding peak–interval frequencies are approximately 14.98 and 14.75 kHz. Thus, both cases lie within the same approximately 15 kHz low-frequency oscillation band. The corresponding FFT-bin and peak–interval frequency results are summarized in Table 5.
Figure 5.
Discharge-current FFT comparison between the co-simulation and fixed-voltage simulations over 1–5 ms using a common 1.0 μs time base and a Hann window.
Table 5.
FFT and peak–interval frequency comparison in the 1–5 ms window.
Because the FFT-bin difference of 0.25 kHz corresponds to one frequency bin, it is reported as a small difference between the identified spectral peaks rather than as a statistically established physical frequency shift. Differences in the harmonic amplitudes nevertheless indicate modest changes in waveform shape under the dynamic port boundary.
The operating condition with a magnetic-field scaling factor of 1.4 and an anode mass flow rate of 5 mg/s was used as the common reference for the operating-parameter comparison. This condition corresponds to the main co-simulation condition adopted in the preceding analysis and exhibits a bounded and sustained low-frequency discharge-current oscillation after the start-up transient. It therefore provides a representative dynamic state for examining how the coupled discharge response changes with magnetic-field strength and propellant supply.
Two one-factor-at-a-time comparisons were conducted around this reference condition. For the magnetic-field comparison, the scaling factor was varied from 1.2 to 1.6 while the anode mass flow rate was fixed at 5 mg/s. The value 1.4 lies at the center of the investigated magnetic-field range and permits the effects of both a decrease and an increase in field strength to be evaluated relative to the same oscillatory operating state. For the mass-flow comparison, the anode mass flow rate was varied from 5 to 7 mg/s while the magnetic-field scaling factor was fixed at 1.4.
All comparison cases were recalculated using 200 axial cells and a 10 ms simulation duration. The discharge voltage, co-simulation macro-step, physical models, transport and wall-loss closures, and remaining boundary conditions were kept unchanged. Consequently, the observed variations in mean current, oscillation amplitude, and dominant frequency can be attributed primarily to the operating parameter being examined. The resulting discharge-current responses are presented in Figure 6.
Figure 6.
Discharge-current responses for the operating-parameter comparison. Left column: magnetic-field scaling-factor variation at 5 mg/s; right column: anode mass-flow-rate variation at . The , 5 mg/s condition is repeated as the common reference.
A preliminary operating-parameter screening, presented here to justify the selected reference condition, was conducted before the detailed main-case analysis. As shown in Figure 6, when the magnetic-field scaling factor is reduced to 1.2, the discharge-current fluctuation becomes significantly stronger. However, the oscillation amplitude is excessively large and the waveform is less regular, making it difficult to obtain a stable and clearly defined breathing-mode response. When the magnetic-field scaling factor is increased to 1.6, the oscillation is markedly suppressed. In particular, the current fluctuation gradually decays during the late-time interval, and a sustained and distinguishable dominant oscillation cannot be maintained. Therefore, neither of these magnetic-field conditions is suitable as the reference condition for the subsequent analysis.
At , increasing the anode mass flow rate raises the mean discharge current but does not produce a more representative oscillatory response. The 6 mg/s condition exhibits a relatively large oscillation amplitude and stronger waveform fluctuations, with weaker periodicity and regularity than those observed at 5 mg/s. The 7 mg/s condition shows pronounced fluctuations during the early stage, followed by a clear reduction in oscillation amplitude, resulting in inconsistent dynamic characteristics between the two time intervals. This behavior makes it unsuitable as a stable comparison baseline. In contrast, the , 5 mg/s condition maintains a relatively clear, regular, and sustained low-frequency oscillation throughout the entire analysis interval. It exhibits neither excessively strong and irregular current fluctuations nor an obvious late-time decay in oscillation amplitude, and therefore provides a representative sustained low-frequency oscillation for the present numerical comparison. Accordingly, this condition is selected as the reference operating condition for the subsequent numerical-sensitivity analysis.
Table 6 summarizes the one-factor-at-a-time numerical-sensitivity checks. Halving the communication macro-step from 1.0 to 0.5 μs leaves the dominant FFT frequency unchanged, while the differences in the mean current, standard deviation, and peak-to-peak current are 0.04%, 0.39%, and 4.52%, respectively. Reducing the maximum adaptive internal step from 5 to 2.5 ns also leaves the dominant frequency unchanged, with differences of 0.07%, 0.36%, and 1.95% in the corresponding current metrics. Refining the axial grid from 200 to 400 cells results in differences of 0.07%, 2.21%, 4.87%, and 1.69% in the mean current, standard deviation, peak-to-peak current, and dominant frequency, respectively. These results indicate limited sensitivity of the principal port-level quantities to the selected numerical settings and support the use of a 1.0 μs communication macro-step, a 5 ns maximum internal step, and a 200-cell grid for the present analysis.
Table 6.
Summary of the numerical-sensitivity checks for the main co-simulation case.
The port-current comparison alone cannot determine whether the internal thruster solution changes. To examine this point, this study compares the spatiotemporal distributions of , , , , and over 4.55–4.90 ms. This 0.35 ms window covers approximately five low-frequency cycles and reveals the periodic evolution of the ionization, acceleration, and electron-heating regions. These quantities are solved or diagnosed internally by HallThruster.jl and are not transmitted to Saber as port variables. The maps are plotted from the native 1 μs diagnostic output on the 200-cell grid using common axes and color scales; no temporal or spatial smoothing is applied. The comparison therefore tests whether the small port-boundary perturbation is accompanied by changes within the internal discharge solution.
Figure 7 and Figure 8 show the local spatiotemporal distributions of electron density and neutral density, respectively. Both boundary conditions exhibit the same repeated electron-density enhancement and neutral depletion–replenishment pattern, with very similar overall axial locations and morphologies. The most visible differences are a relative phase displacement and localized changes in the intensity and continuity of the stripes; the distribution remains nearly unchanged apart from a slight temporal displacement near the depletion boundary. Isolated cell-scale high-value features in the electron-density maps are retained from the unsmoothed diagnostic output, and the interpretation is based on the repeated stripe structures rather than individual pixels. These results indicate a limited modulation of the ionization evolution rather than a transition to a different discharge regime.
Figure 7.
Local comparison of electron density between the co-simulation and fixed-voltage simulation.
Figure 8.
Local comparison of neutral density between the co-simulation and fixed-voltage simulation.
Figure 9 and Figure 10 compare the potential and axial electric field. Under both boundary conditions, the same main potential-drop region and strong-electric-field region recur with the low-frequency cycle, showing that the overall acceleration-region structure is preserved. The remaining differences are modest and are concentrated in local phase, stripe curvature, and the instantaneous position of the sharpest field gradient. Thus, the dynamic boundary produces a localized perturbation of the ion-acceleration-related region without changing its principal spatial organization.
Figure 9.
Local comparison of potential between the co-simulation and fixed-voltage simulation.
Figure 10.
Local comparison of axial electric field between the co-simulation and fixed-voltage simulation.
Figure 11 shows the local spatiotemporal distribution of electron temperature. The high-value region remains spatially associated with the strong-electric-field region and repeats at the same low-frequency scale in both cases. Small differences in local phase and stripe morphology are visible, but the overall electron-heating region and temperature range remain in the same operating regime. The dynamic port boundary therefore modulates the instantaneous electron-energy evolution without producing a qualitatively different temperature structure.
Figure 11.
Local comparison of electron temperature between the co-simulation and fixed-voltage simulation.
Taken together, Figure 7, Figure 8, Figure 9, Figure 10 and Figure 11 show that the overall internal-field structures are highly similar, consistent with the close mean currents and dominant frequencies of the two calculations. Small but repeatable differences are concentrated in relative phase and localized high-gradient regions. Because electron density, neutral density, potential, axial electric field, and electron temperature are solved internally by HallThruster.jl and are not exchanged as port variables, these differences support the conclusion that the time-varying port-voltage boundary propagates into the internal discharge solution. They do not, however, indicate a large restructuring of the plasma state. These results demonstrate synchronized bidirectional port coupling while showing that the principal thruster operating mode is preserved.
3.2. Comparison of Power-Supply Response Characteristics Under Resistive and Hall-Thruster Loads
To evaluate the influence of the Hall-thruster dynamic load on the power-supply output response, the Saber power stage was simulated under two load conditions: a fixed resistive load and the online Hall-thruster load. The fixed-load branch consisted of the 130 Ω load resistance together with the 4.5 Ω series resistance used in the Saber model. The same power-stage topology, component parameters, gate-pulse settings, and simulation duration were adopted in both cases. Under the resistive-load condition, the load current was determined only by the circuit voltage and the prescribed resistance. Under the Hall-thruster-load condition, the discharge current was calculated from the evolving plasma state in HallThruster.jl and returned to the Saber circuit at each communication step. The resistive-load case therefore provides a static-load baseline for distinguishing the inherent response of the power stage from the additional modulation associated with the time-varying thruster current.
As shown by the global responses in Figure 12, both load conditions exhibit a rapid output-voltage rise, an initial overshoot, and a subsequent settling process. These common features are mainly associated with the open-loop voltage-establishment transient of the representative power stage, including the charging of the output capacitors and the establishment of the filter-inductor currents. Because the Saber power stage is operated using fixed gate pulses and does not include a closed-loop voltage compensator, this response represents the start-up and natural filter-network dynamics rather than a closed-loop voltage-regulation process. Under the resistive load, the oscillation following the initial overshoot gradually decreases because the prescribed resistance does not introduce an additional time-varying internal state. The remaining relatively slow and low-amplitude fluctuation is therefore mainly associated with the lightly damped response of the output filter network.
Figure 12.
Global and enlarged late-time output-voltage responses under resistive and Hall-thruster loads.
The Hall-thruster-load case exhibits a distinctly different late-time response. After the initial voltage-establishment transient, a sustained periodic ripple remains superimposed on the output voltage. In the enlarged 4–5 ms interval shown in Figure 12, the mean output voltages are approximately 262 V under the resistive load and 242.84 V under the Hall-thruster load. The corresponding peak-to-peak voltage values are approximately 2.21 and 5.45 V, respectively, giving a case-specific ripple ratio of approximately 2.47. The two cases establish different mean operating points and were not adjusted to match the same average voltage, current, or power. Therefore, this ratio should not be interpreted as a universal ripple-amplification factor. Nevertheless, the comparison clearly shows that a stronger sustained output-voltage modulation occurs when the time-varying Hall-thruster current is applied to the representative power stage.
The sustained voltage ripple under the Hall-thruster load is attributed to the interaction between the oscillatory discharge-current demand and the finite impedance of the power-stage output network. Variations in neutral replenishment, ionization, charged-particle transport, and the acceleration-region state produce a periodically varying discharge current inside the thruster. This current is returned to the Saber model through the co-simulation interface and produces a corresponding voltage response across the output capacitors, filter inductors, connection paths, and other circuit elements. The frequency scale of the higher-frequency voltage component under the Hall-thruster load is also consistent with the low-frequency discharge-current oscillation identified in the preceding analysis. In contrast, the slower and smaller fluctuation under the resistive load primarily reflects the inherent dynamics of the power-supply output network.
The Hall-thruster-load voltage waveform is not an ideal single-frequency sinusoid, because the nonlinear discharge-current oscillation contains waveform distortion and harmonic components, which interact with the frequency-dependent impedance of the output network. The observed voltage ripple should therefore be interpreted as a coupled port response rather than as an oscillation generated solely by the thruster or the power stage. The fixed resistive load remains useful for evaluating the basic start-up, filtering, and steady-output behavior of the representative circuit, but it cannot reproduce the sustained dynamic-current demand generated by the modeled Hall-thruster discharge process. The online co-simulation consequently provides a dynamically varying load boundary for investigating power-port voltage ripple. A complete component-stress assessment and rigorous frequency-domain impedance identification are beyond the scope of the present study and will be addressed using a more complete PPU model in future work.
4. Discussion
To address the difficulty of real-time coupling of Hall-thruster loads in propulsion power-supply output-stage simulation, this paper establishes a HallThruster.jl–Simulink–Saber port-level online co-simulation method. In this method, the output-port voltage from Simulink–Saber is used as the instantaneous discharge boundary of HallThruster.jl, and the discharge current calculated from the internal thruster state is returned to the power-supply output stage. In this way, synchronized bidirectional port coupling between the propulsion power-supply output stage and the one-dimensional thruster discharge model is achieved.
The 200-cell main co-simulation case shows that, after the start-up transient, the discharge current forms a sustained low-frequency periodic oscillation. In the 1–5 ms and 5–10 ms windows, the dominant frequencies are approximately 15.00 kHz and the peak-to-peak values are approximately 6.93 A and 5.97 A, respectively. Compared with the fixed-voltage reference, the online co-simulation retains nearly identical mean-current levels and the same dominant-frequency band. In the 4.20–4.95 ms local window, the peak-to-peak values differ by only about 1.4% (5.72 versus 5.80 A). The more consistent distinctions are the relative phase, cycle-scale waveform shape, above-/below-mean current occupancy, and harmonic amplitudes. These results indicate that the power-supply port boundary modestly modulates the thruster response without changing its principal oscillation mode.
The identified 14.75–15.00 kHz FFT band is consistent in order of magnitude with independent SPT-100 evidence. Sankovic et al. reported a prominent discharge-current oscillation at 16.8 kHz during SPT-100 testing at NASA LeRC [25]. Hara et al. reported SPT-100 breathing-mode frequencies of approximately 20–25 kHz in a hybrid simulation and noted consistency with previous SPT-100 experiments [26]. The present frequency is therefore reasonably close to the measured 16.8 kHz value and falls within the low-frequency range reported for SPT-100-related studies. Because the cited experiments and simulations do not use exactly the same discharge voltage, magnetic-field scaling, wall treatment, and electron-transport closure as the present case, this comparison is used as an independent physical-plausibility check rather than as a direct one-to-one validation. This qualification is also consistent with the intended partially predictive use of HallThruster.jl, for which detailed quantitative agreement can depend on model calibration [21]. In addition, the 0.25 kHz difference between the co-simulation and fixed-voltage reference FFT bins corresponds to one frequency bin and is not treated as a statistically established physical frequency shift.
The internal-field comparison further shows that the two cases retain very similar electron-density, neutral-density, potential, axial-electric-field, and electron-temperature structures. The observable differences are small and localized, primarily involving relative phase and high-gradient regions. Because these quantities are calculated inside HallThruster.jl rather than transmitted through the port interface, the differences indicate that the dynamic voltage boundary enters the internal solution, while the close overall structures confirm that the principal discharge regime is unchanged. The resistive-load comparison separately shows that a fixed load reproduces the basic voltage-rise response but not the sustained ripple associated with the modeled thruster dynamics.
The present study focuses on synchronized port-level coupling between a representative propulsion power-supply output stage and the Hall-thruster discharge model. Future work will extend the framework by incorporating complete PPU control and protection functions, multi-output coordination, and component parasitic parameters for system-level analyses of output ripple, dynamic-load matching, and component stress.
Author Contributions
Conceptualization, Z.F., Y.Z. and L.W.; methodology, Z.F. and Y.Z.; software, Z.F.; validation, Z.F.; formal analysis, Z.F.; investigation, Z.F.; resources, L.W.; data curation, Z.F.; writing—original draft preparation, Z.F.; writing—review and editing, Y.Z., J.L., Y.T., L.S., S.W. and L.W.; visualization, Z.F.; supervision, Y.Z. and L.W.; project administration, L.W. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the Key Research and Development Program of Heilongjiang Province, grant number 2024ZX05B07, and the Advanced Space Propulsion Laboratory of BICE and Beijing Engineering Research Center of Efficient and Green Aerospace Propulsion Technology, grant number LabASP-2023-02.
Data Availability Statement
The data presented in this study are available from the corresponding author upon reasonable request.
Acknowledgments
The authors would like to thank the members of the research group for their helpful discussions and technical support during the development of the HallThruster.jl–Simulink–Saber co-simulation platform.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Franco, D.K.; Shoor, B.; Davidson, A.; Zimmerman, R.; Appel, L.; Rinski, V.; Lev, D.; Herscovitz, J. On-orbit mission overview of the low power Hall thruster propulsion system aboard Venμs satellite. J. Electr. Propuls. 2024, 3, 15. [Google Scholar] [CrossRef] [Scilit]
- Hsu, A.; Dragnea, H.; Schilling, J.; Doumitt, A. 2023 Small Satellite Propulsion Technologies Compendium; Version 1.41; OTR-2024-00338; The Aerospace Corporation: Chantilly, VA, USA, 2024; pp. 1–458. Available online: https://aerospace.org/sites/default/files/2024-02/20231218%20Small%20Satellite%20Propulsion%20Survey_DISTRO_A.pdf (accessed on 26 July 2026).
- Goebel, D.M.; Katz, I. Fundamentals of Electric Propulsion: Ion and Hall Thrusters; Wiley: Hoboken, NJ, USA, 2008. [Google Scholar]
- Petrenko, O.; Alekseenko, O.; Tolmachov, V. Power processing and control unit of the electric propulsion system. J. Rocket-Space Technol. 2023, 32, 15–22. [Google Scholar]
- Fang, M.; Zhang, D.; Qi, X. A novel power processing unit (PPU) system architecture based on HFAC bus for electric propulsion spacecraft. IEEE J. Emerg. Sel. Top. Power Electron. 2022, 10, 5381–5391. [Google Scholar] [CrossRef] [Scilit]
- Rhodes, C.R.; Benavides, G.F.; Piñero, L.R. Sub-kW class Hall-effect thruster power processing unit for wide output range applications. In Proceedings of the 38th International Electric Propulsion Conference, Toulouse, France, 23–28 June 2024. IEPC-2024-331. [Google Scholar]
- Choueiri, E.Y. Plasma oscillations in Hall thrusters. Phys. Plasmas 2001, 8, 1411–1426. [Google Scholar] [CrossRef] [Scilit]
- Boeuf, J.-P.; Garrigues, L. Low frequency oscillations in a stationary plasma thruster. J. Appl. Phys. 1998, 84, 3541–3554. [Google Scholar] [CrossRef] [Scilit]
- Lafleur, T.; Chabert, P.; Bourdon, A. The origin of the breathing mode in Hall thrusters and its stabilization. J. Appl. Phys. 2021, 130, 053305. [Google Scholar] [CrossRef] [Scilit]
- Dale, E.T.; Jorns, B.A. Experimental characterization of Hall thruster breathing mode dynamics. J. Appl. Phys. 2021, 130, 133302. [Google Scholar] [CrossRef] [Scilit]
- Chapurin, O.; Smolyakov, A.; Hagelaar, G.J.M.; Raitses, Y. On the mechanism of ionization oscillations in Hall thrusters. J. Appl. Phys. 2021, 129, 233307. [Google Scholar] [CrossRef] [Scilit]
- Chapurin, O.; Smolyakov, A.; Hagelaar, G.J.M.; Boeuf, J.-P.; Raitses, Y. Fluid and hybrid simulations of the ionization instabilities in Hall thrusters. J. Appl. Phys. 2022, 132, 053301. [Google Scholar] [CrossRef] [Scilit]
- Petronio, F.; Laguna, A.A.; Bourdon, A.; Chabert, P. Study of the breathing mode development in Hall thrusters using hybrid simulations. J. Appl. Phys. 2024, 135, 073301. [Google Scholar] [CrossRef] [Scilit]
- Leporini, L.; Giannetti, V.; Saravia, M.M.; Califano, F.; Camarri, S.; Andreussi, T. On the onset of breathing mode in Hall thrusters and the role of electron mobility fluctuations. Front. Phys. 2022, 10, 951960. [Google Scholar] [CrossRef] [Scilit]
- Leporini, L.; Giannetti, V.; Saravia, M.M.; Califano, F.; Camarri, S.; Andreussi, T. An unstable 0D model of ionization oscillations in Hall thrusters. Front. Phys. 2023, 10, 1097813. [Google Scholar] [CrossRef] [Scilit]
- Gottfried, J.A.; Antozzi, S.; Stienike, J.; Thompson, S.J.; Williams, J.D.; Yalin, A.P. Temporally resolved relative krypton neutral density during breathing mode of a Hall effect thruster recorded by TALIF. J. Electr. Propuls. 2024, 3, 9. [Google Scholar] [CrossRef] [Scilit]
- Brieda, L.; Koo, J.; Scharfe, M. Influence of a power supply model on simulated Hall thruster discharge voltage oscillations. AIP Adv. 2019, 9, 025320. [Google Scholar] [CrossRef] [Scilit]
- Simmonds, J.; Raitses, Y.; Smolyakov, A.; Chapurin, O. Studies of a modulated Hall thruster. Plasma Sources Sci. Technol. 2021, 30, 055011. [Google Scholar] [CrossRef] [Scilit]
- Jovel, D.R.; Cabrera, J.D.; Walker, M.L.R. Hall effect thruster impedance characterization in ground-based vacuum test facilities. J. Electr. Propuls. 2024, 3, 31. [Google Scholar] [CrossRef] [Scilit]
- Jorns, B.A.; Dale, E.; Hofer, R.R. Mode transitions in a magnetically shielded Hall thruster. I. Experimentally informed model. J. Appl. Phys. 2024, 136, 053301. [Google Scholar] [CrossRef] [Scilit]
- Marks, T.; Schedler, P.; Jorns, B. HallThruster.jl: A Julia package for 1D Hall thruster discharge simulation. J. Open Source Softw. 2023, 8, 4672. [Google Scholar] [CrossRef] [Scilit]
- The MathWorks, Inc. Simulink, version 8.6 (R2015b); The MathWorks, Inc.: Natick, MA, USA, 2015.
- Synopsys, Inc. Synopsys Saber, version 2016; Synopsys, Inc.: Sunnyvale, CA, USA, 2016.
- Dragnea, H.C.; Ortega, A.L.; Kamhawi, H.; Boyd, I.D. Simulation of a Hall Effect Thruster Using Krypton Propellant. J. Propuls. Power 2020, 36, 335–345. [Google Scholar] [CrossRef] [Scilit]
- Sankovic, J.M.; Hamley, J.A.; Haag, T.W. Performance evaluation of the Russian SPT-100 thruster at NASA LeRC. In Proceedings of the 23rd International Electric Propulsion Conference, Seattle, WA, USA, 13–16 September 1993. IEPC-93-094. [Google Scholar]
- Hara, K.; Boyd, I.D.; Sekerak, M.J.; Gallimore, A.D. Breathing mode in Hall effect thrusters. In Proceedings of the Joint Conference of the 30th International Symposium on Space Technology and Science, the 34th International Electric Propulsion Conference, and the 6th Nano-Satellite Symposium, Kobe-Hyogo, Japan, 4–10 July 2015. IEPC-2015-283/ISTS-2015-b-283. [Google Scholar]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.













