Next Article in Journal
Analysis and Design of a Smart Controller for Managing Penetration of Renewable Energy Including Cybersecurity Issues
Previous Article in Journal
Managed Evolution of Automotive Software Product Line Architectures: A Systematic Literature Study
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Multi-Intensity Optimization-Based CT and Cone Beam CT Image Registration

School of Information Science and Engineering, Yunnan University, Kunming 650500, China
*
Author to whom correspondence should be addressed.
Electronics 2022, 11(12), 1862; https://doi.org/10.3390/electronics11121862
Submission received: 19 May 2022 / Revised: 8 June 2022 / Accepted: 9 June 2022 / Published: 13 June 2022
(This article belongs to the Section Computer Science & Engineering)

Abstract

Cancer is a highly lethal disease that is mainly treated by image-guided radiotherapy. Because the low dose of cone beam CT is less harmful to patients, cone beam CT images are often used for target delineation in image-guided radiotherapy of various cancers, especially in breast and lung cancer. However, breathing and heartbeat can cause position errors in images taken during different periods, and the low dose of cone beam CT also results in insufficient imaging clarity, rendering existing registration methods unable to meet the CT and cone beam CT registration tasks. In this paper, we propose a novel multi-intensity optimization-based CT and cone beam CT registration method. First, we use a multi-weighted mean curvature filtering algorithm to preserve the multi-intensity details of the input image pairs. Then, the strong edge retention results are registered using and intensity-based method to obtain the multi-intensity registration results. Next, a novel evaluation method called intersection mutual information is proposed to evaluate the registration accuracy of the different multi-intensity registration results. Finally, we determine the optimal registration transformation by intersection mutual information and apply it to the input image pairs to obtain the final registration results. The experimental results demonstrate the excellent performance of the proposed method, meeting the requirements of image-guided radiotherapy.
Keywords: CT; cone beam CT; registration; image-guided radiotherapy CT; cone beam CT; registration; image-guided radiotherapy
Graphical Abstract

Share and Cite

MDPI and ACS Style

Xie, L.; He, K.; Gong, J.; Xu, D. Multi-Intensity Optimization-Based CT and Cone Beam CT Image Registration. Electronics 2022, 11, 1862. https://doi.org/10.3390/electronics11121862

AMA Style

Xie L, He K, Gong J, Xu D. Multi-Intensity Optimization-Based CT and Cone Beam CT Image Registration. Electronics. 2022; 11(12):1862. https://doi.org/10.3390/electronics11121862

Chicago/Turabian Style

Xie, Lisiqi, Kangjian He, Jian Gong, and Dan Xu. 2022. "Multi-Intensity Optimization-Based CT and Cone Beam CT Image Registration" Electronics 11, no. 12: 1862. https://doi.org/10.3390/electronics11121862

APA Style

Xie, L., He, K., Gong, J., & Xu, D. (2022). Multi-Intensity Optimization-Based CT and Cone Beam CT Image Registration. Electronics, 11(12), 1862. https://doi.org/10.3390/electronics11121862

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop