Skip to Content
Applied SciencesApplied Sciences
  • Article
  • Open Access

30 June 2026

15 Pages

Dual-Mode Detection of the Non-Traditional Preservative Caprylhydroxamic Acid in Cosmetics: A Green Chemistry Approach

,
,
,
,
and
1
NMPA Key Laboratory for Research and Evaluation ofCosmetics, National Institutes for Food and Drug Control, Beijing 100050, China
2
Gansu Institute for Drug Control, Lanzhou 730070, China
3
Chongqing Key Laboratory of Quality Control and Safety Evaluation of Active Pharmaceutical Ingredients, Chongqing Institute for Food and Drug Control, Chongqing 400713, China
*
Author to whom correspondence should be addressed.
This article belongs to the Section Chemical and Molecular Sciences

Abstract

Caprylhydroxamic acid (CHA) exhibits strong chelating capacity toward several metal ions and thereby inhibits microbial growth. Not being a conventional preservative, CHA is typically viewed as an emerging alternative in cosmetic formulations. Despite its growing application, CHA is not explicitly regulated under current EU, USA or Chinese cosmetic guidelines, leading to unsupervised usage and potential safety concerns. Consequently, there is an urgent need to establish reliable analytical methods for the detection of CHA in cosmetics, ensuring product safety and regulatory compliance. Herein, a chromogenic system is developed for the dual-mode detection of CHA in cosmetics, allowing both quantitative spectrophotometric and semi-quantitative colorimetric analysis. First of all, Fe3+ is introduced to catalyze the oxidation of 3,3′,5,5′-tetramethylbenzidine (TMB) under acidic conditions to produce a blue color. When CHA is added, it chelates Fe3+ strongly, forming a stable complex that competes with the TMB oxidation reaction, thereby causing the blue color to fade. The change in absorbance of the system at 656 nm exhibits a linearity with the concentrations of CHA ranging from 0.1 mmol/L to 2.0 mmol/L. The proposed method enables the detection of CHA in various cosmetics, including facial mask, cream, spray, and toner. A detection limit of 0.007% was achieved, far below the 0.3% limits set by South Korea and Australia, confirming its compliance with regulatory monitoring requirements. AGREE assessment of the method gave a score of 0.76, demonstrating its greenness. The dual-mode detection approach serves as an effective, rapid on-site screening tool, working alongside HPLC-UV for confirmatory analysis in the laboratory. In summary, the method is free of complex pretreatment and expensive instruments, providing a low-cost, on-site, and green approach for rapid screening. It can serve as a complement to routine laboratory detection methods.

1. Introduction

As essential daily products, cosmetic matrices comprise a complex blend of ingredients, including oils, emulsifiers, active substances, thickeners, and so on [1]. The nutrient-rich formulations are prone to microbial contamination, both intrinsically and through external sources during usage. Residual metal elements in cosmetics, such as Fe3+ and Cu2+, further promote microbial growth. For instance, Fe3+ participates in the redox center of iron−sulfur proteins within the electron transport chain and is involved in the reduction of nucleotide precursors [2]. Accordingly, certain ingredients are routinely added to cosmetic formulas to exert a preservative effect [3].
Caprylhydroxamic acid (CHA), also known as octyl hydroxamic acid or N-hydroxy-n-octanamide, exhibits keto−enol tautomerism. This tautomerism is characterized by the spatial proximity of the oxygen and nitrogen atoms within the oxime group, both of which possess lone pair electrons [4,5]. Therefore, it can form stable multi-cyclic metal chelates with various metal ions [6,7,8]. Leveraging its efficient and selective chelation of metal ions, CHA has been extensively applied in the fields of medicine [9,10], mineral flotation [11], metallurgy [12], cosmetics [13], etc. CHA exhibits antibacterial efficacy at neutral pH, along with high stability, strong antifungal activity, and excellent compatibility with most cosmetic raw materials. By inhibiting the activity of metal ions, CHA prevents turbidity, oxidation, and discoloration in products or raw materials, and thus extends the shelf life of cosmetic ingredients and finished products.
Cosmetics containing CHA have appeared in the markets of the EU and US since the beginning of this century. The number of personal care products containing CHA has rapidly increased in recent years. According to the new product database of MINTEL, it is indicated that a large base of usage worldwide currently contain CHA [14]. CHA exhibits effective antimicrobial and preservative properties, whereas it is not included in the list of approved preservatives for cosmetic products in either the EU or China. Due to cosmetics without preservatives being more popular among consumers, CHA is added in more and more cosmetics by manufacturers as a preservative while claiming “NO preservatives” to achieve promotional effects. More significantly, a rising number of reports identify CHA as a growing allergen in skin care products [15]. Regarding the usage limit of CHA in cosmetics, only Australia and South Korea currently stipulate that its maximum mass fraction shall not exceed 0.3%. Most countries lack defined usage limits for CHA, creating regulatory ambiguity and potential safety concerns for its application in cosmetics. However, the current detection method for CHA in cosmetics is scarce. Li et al. [16] reported the determination of CHA in human urine using ultra-performance liquid chromatography coupled with HRMS (UHPLC-HRMS), involving extraction with organic solvents and spiking with 13C6-methylparaben, and LOD was 2.5 ng/mL. However, this method requires large-scale instrumentation and skilled laboratory personnel and is time-consuming, which is inconsistent with the global regulatory concept of green chemistry. Therefore, it is essential to develop a simple, reliable, green, and cost-effective method for detecting CHA in cosmetics.
As a novel, safe reducing agent, 3,3′,5,5′-tetramethylbenzidine (TMB) has gradually replaced the potent carcinogen benzidine and its carcinogenic derivatives, and exhibits strong absorption in the ultraviolet region [17,18]. TMB possesses a unique symmetrical molecular structure containing two -NH2 groups. It can be oxidized by various oxidants to form charge-transfer complexes or diimide structures, enabling its use as a chromogenic substrate [19]. The amino groups on its benzene ring confer high redox activity, facilitating electron transfer and resulting in a high molar absorptivity (ε > 105 mol·L−1·cm−1) [20]. It produces a stable and significant color change that is highly visible to the naked eye [20]. Compared to other colorimetric probes, TMB is widely employed in analytical chemistry due to its advantages of rapid response, simplicity, suitability for on-site testing, and low cost [21,22,23]. As a result, TMB has found broad applications in clinical diagnostics [24], biochemical [25,26], and environmental monitoring [27,28,29]. It is also capable of detecting illegal adulterants in anti-acne cosmetics [30]. However, its application for the detection of CHA in cosmetic analysis has not been reported.
In the study, TMB was employed as both a chromogenic agent and chromogenic substrate, which was reduced by Fe3+ to form a color development reaction under acidic conditions [31]. Based on this, CHA was subsequently introduced to form a stable chelate with Fe3+ [32], leading to a decolorization reaction, as illustrated in Scheme 1. The absorbance variation at 656 nm was proportional to the CHA concentration. Accordingly, a spectrophotometric method was established for the quantitative determination of CHA in cosmetics. By simplifying the colorimetric system, this approach holds the potential for the development of a low-cost, sensitive, and visual detection method, thereby significantly reducing overall equipment costs. Additionally, this colorimetric method offers the advantages of convenient and rapid detection, which further facilitates its practical application.
Scheme 1. Schematic illustration of the colorimetric detection of CHA in cosmetics.

2. Materials and Methods

2.1. Chemicals and Apparatus

The standard CHA was purchased from J&K Technology Co., Ltd. (Beijing, China). TMB, together with other commonly used traditional preservatives, including benzoic acid, sorbic acid, phenoxyethanol, dehydroacetic acid, triclocarban and methylisothiazolinone, came from Sigma-Aldrich Company (Shanghai, China). Sodium chloride (NaCl) was obtained from Aladdin Scientific Company (Shanghai, China). All chemicals were used as received. Ferric chloride (FeCl3), sodium dihydrogen phosphate (NaH2PO4), Tris, acetic acid (HAc), sodium acetate (NaAc), citric acid (CA), and sodium citrate (SC) were from National Pharmaceutical Reagent (Beijing, China). The experimental water was ultrapure water.
Absorption spectra were recorded by a UV-2700 spectrophotometer from Shimadzu Corporation (Kyoto, Japan). A G10 centrifuge (Beijing Baiyang Medical Equipment, Beijing, China) and a Vortex-5 Oscillator (Qilin Bell Instrument, Haimen, China) were used for sample processing. Ultrasonic extraction was carried out using a KQ-700DE cleaner (Kunshan Ultrasonic Instrument, Kunshan, China), and an AL204 balance (Sartorius, Ann Arbor, MI, USA) was used for weighing. Cosmetics samples were purchased from the local market in Beijing, China.

2.2. Preparation of Standard Solution

An accurate amount of CHA standard was weighed and dissolved in methanol in a 10 mL volumetric flask to prepare a 20.0 mmol/L stock solution, which was stored at −20 °C. Working solutions at concentrations of 0.1~2.0 mmol/L (0.1, 0.2, 0.5, 0.8, 1.0, 1.5, and 2.0 mmol/L) were obtained by diluting the stock solution with water.

2.3. Detection of CHA by Spectrophotometer

Aliquots of TMB (500 μL, 0.8 mmol/L) and FeCl3 (500 μL, 0.5 mmol/L) were sequentially added to colorimetric tubes, followed by rapid addition of 1.5 mL of NaAc-HAc buffer solution (15 mmol/L, pH 3.8). The mixture was incubated in a 40 °C water bath for 7 min, and an obvious blue color was observed. Then, 500 μL of CHA standard solutions at various concentrations were added, and the tubes were incubated again at 40 °C for 5 min. The resulting solution was then transferred to a 3 mL quartz cuvette for measurement. The absorption spectra were recorded in the range of 400–700 nm using a spectrophotometer. The colored product exhibited a maximum absorption peak at 656 nm, which can be directly utilized for quantitative determination. The absorbance of the system containing without CHA was denoted as A0, while that of the sample system containing CHA solution was denoted as A. The absorbance difference (ΔA) was defined as the difference between A0 and A (ΔA = A0 − A). A calibration curve was constructed by plotting the CHA concentration (on the horizontal axis) against the corresponding ΔA (on the vertical axis). Obvious color fading was observed under different concentrations of CHA, enabling convenient qualitative recognition of CHA via the naked eye.

2.4. Pretreatment and Determination of Cosmetics

Aliquots of 0.5 g of cosmetic samples were weighed and placed into a 10 mL capped centrifuge tube. Then, 1 mL of saturated NaCl solution was added for sufficient dispersion, followed by sequential addition of water to 10 mL, and brief vortex mixing for 2 min to ensure homogenization. After being centrifuged at 10,000 rpm for 5 min, 500 μL of the supernatant was taken and added to the blue TMB-Fe3+ solution for quantitative measurement. The absorbance of TMB-Fe3+ solution before and after adding the extract was recorded. The resulting change in absorbance is substituted into the standard curve to calculate the CHA content in the sample.

2.5. Data Analysis and Calculation

The calibration curve was constructed by plotting ΔA against the analyte concentration c, and was described by Equation (1):
ΔA = kc + b
where ΔA, which is unitless, refers to the absorbance difference in absorbance between the color-developing and color-fading steps at 656 nm, k is the slope of the calibration curve, c represents the concentration of the target analyte (mmol/L), and b is the intercept of the regression line.
The limit of detection (LOD) was calculated according to the IUPAC-recommended formula:
LOD = 3 σ k
where σ denotes the standard deviation of absorbance measurements for blank samples (n = 11), and k represents the slope of the linear calibration curve obtained from Equation (1). The limit of quantification (LOQ), defined as the lowest concentration that can be reliably quantified, was determined based on 10σ/k.
The mass content of CHA in the cosmetic product was calculated according to the following Formula (3):
ω = c   ×   V   ×   159.23 m   ×   10
where ω (%) represents the mass content of CHA in the cosmetic product, and c represents the concentration of CHA in the cosmetic extraction solution, which was calculated based on the calibration curve, with units of mmol/L. In addition, 159.23 is the molecular weight of CHA. V is the constant volume after adding an appropriate amount of water to the cosmetic product, with units of L. m is the mass of the weighed cosmetic sample, with units of g.
The spike recovery was calculated using the following Equation (4):
R e c o v e r y ( % ) = c m e a s u r e d   −   c b a c k g r o u n d c s p i k e d × 100 %
where cmeasured is the measured concentration in spiked samples, cbackground refers to the intrinsic background concentration, and cspiked denotes the spiked concentration of the analyte.

3. Experimental Conditions

CHA is presumed to exist in both keto and enol tautomeric forms, as shown in Figure 1. The keto form tends to predominate under acidic conditions, whereas the enol form may dominate under alkaline conditions. The hydroxamic acid moiety enables CHA to act as a chelating agent, which facilitates the rapid formation of strong complexes with oxidized transition metals [33,34]. Based on this mechanism, a two-step reaction was designed for the quantitative detection of CHA, wherein CHA competes with the chromogenic substrate TMB for Fe3+, leading to a modulated colorimetric response. As the assay involves two reaction steps, which are color development followed by decolorization, multiple experimental factors can affect its sensitivity. Therefore, key parameters, including buffer solution, reaction temperature, and reaction time, were systematically optimized.
Figure 1. Caprylhydroxamic Acid.

3.1. Buffer Types

Typically, Fe3+ promotes the redox reactions of TMB under acidic conditions [35]. To optimize this process, several commonly used acidic buffer solutions, including HAc-NaAc, Tris-HCl, NaH2PO4, and CA-SC, were investigated at the same concentration (20 mmol/L) and pH (4.0). Among the buffers tested, as shown in Figure 2A, the HAc-NaAc buffer solution produced the highest signal response, while the Tris-HCl buffer showed a lower response, and no detectable signal was obtained with the CA-SC or NaH2PO4 buffer. The observed phenomenon can be attributed to the fact that the color development reaction in this study is catalyzed by free Fe3+. Strong chelators (e.g., phosphate and citrate) or reducing agents (e.g., Tris) inhibit the reaction, whereas acetate, with its negligible coordination ability, allows maximum catalytic activity. Therefore, HAc-NaAc buffer was chosen in order to realize higher sensitivity.
Figure 2. Optimization of the experimental conditions when using (A) different types of buffer solution at pH 4.0, (B) effect of pH, (C) concentration of HAc-NaAc buffer solution and (D) reaction temperature.

3.2. Effect of the pH

The response of TMB is also dramatically affected by the pH range of the buffer. Therefore, the performance of the TMB-Fe3+ colorimetric system was evaluated using HAc-NaAc buffer over a range of pH values. As shown in Figure 2B, the ΔA exhibited significant enhancement from pH 2.5 to 3.5 and reached the highest response at pH 3.8. An obvious downward trend of ΔA was discovered with further increment of pH value from 3.8 to 4.5. The absorption band at 656 nm originates from the probable charge transfer complex formed between the diamine (TMB) as the donor and the diamine dication (TMB2+) as the acceptor [36], catalyzed by Fe3+. Below pH 3.8, high proton concentration protonates TMB and suppresses Fe3+-mediated radical generation, limiting the oxidation reaction. Above pH 3.8, Fe3+ progressively hydrolyzes into catalytically inactive iron hydroxides, reducing the availability of free Fe3+ and thereby decreasing absorbance. At pH 3.8, these two opposing effects are optimally balanced, facilizing the formation of this TMB-based charge-transfer complex. Hence, a pH of 3.8 was a preferable condition.

3.3. Effect of Buffer Concentration

The ΔA of the color reaction was also influenced by the concentration of the buffer solution. Therefore, Hac-NaAc buffer at different concentrations was investigated. Slight enhancement of ΔA was indicated in buffer concentration from 10 mM to 15 mM and the colorimetric outcomes decreased dramatically with further increasing concentration from 15 to 30 mmol/L in Figure 2C. At lower buffer concentrations, the weak monodentate coordination of acetate ions had a negligible effect on free Fe3+. Above 15 mmol/L, excess acetate accumulates to form inactive iron−acetate complexes, and the increased ionic strength reduces dissolved oxygen and radical transfer, collectively decreasing free Fe3+ and thus lowering absorbance. Consequently, 15 mmol/L of HAc-NaAc solution was selected as the optimal buffer concentration to acquire a preferable intensity.

3.4. Effect of Reaction Temperature

To determine the optimal reaction temperature, the complexation reaction was evaluated by measuring the ΔA across a temperature gradient from 25 °C to 50 °C. As shown in Figure 2D, the ΔA exhibited an approximate bell-shaped profile with increasing temperature, which is a significant upward trend of ΔA between 25 °C and 40 °C, but a downward trend between 40 °C and 50 °C. This phenomenon can be attributed to the fact that rising temperature accelerated Fe3+-catalyzed radical generation, enhancing TMB oxidation and blue product accumulation. Above 40 °C, further heating promoted Fe3+ hydrolysis into inactive iron hydroxides, reducing the active catalytic center and thus decreasing both product formation and absorbance. Accordingly, 40 °C was selected as the optimal reaction temperature, which is consistent with previous reports [37].

3.5. Optimization of TMB-Fe3+ Reaction Time (Step 1)

For this two-step reaction of color development first and then fading, greater absorbance in the first step facilitates higher sensitivity. The optimization of reaction time between TMB and Fe3+ is depicted in the accompanying Figure 3A. The time-dependent profile of A0 over 60 min exhibited a distinct unimodal trend, characterized by an initial rapid increase, followed by a peak and a subsequent gradual decline. During the initial phase (1–7 min), A0 increased sharply at 1 min to a maximum at approximately 7 min, indicating a strong and efficient formation or activation process under the experimental conditions. This was followed by a progressive decline phase (7–60 min) where the A0 gradually decreased. This trend suggests the onset of consumption mechanisms. The overall trajectory resembled a consecutive kinetic process, where the initial rapid increase reflects efficient complex formation. Accordingly, 7 min was selected as the optimal reaction time for achieving maximum A0 under the tested conditions.
Figure 3. Time-dependent absorbance changes in the first-step color-developing reaction (A), and time-dependent variations in absorbance difference for the second-step fading reaction (B).

3.6. Optimization of TMB-Fe3+-CHA Reaction Time (Step 2)

Adding CHA to the first-step reaction triggers competitive chelation of Fe3+, which inhibits TMB color generation and fades the blue color. This absorbance variation (ΔA) is then used to quantify CHA. The time-dependent variation in ΔA was monitored over a 20 min reaction period following the addition of CHA with the same concentrations. Figure 3B reveals a non-monotonic trend characterized by an initial gradual increase, a relatively stable phase, and a late-stage rise. During the initial phase, ΔA rose steadily from 1 min to 5 min, indicating a progressive chelation of Fe3+ by CHA. Between 5 and 10 min, ΔA remained relatively stable, suggesting that the coordination reaction had reached saturation. With continued extension of the reaction time, ΔA displayed a weak oscillatory pattern. While a slight increase was observed at 20 min, the gain was insufficient to warrant the extra time. Accordingly, 5 min was adopted as the optimal reaction time to achieve a near-maximal signal efficiently.

4. Results and Discussion

4.1. Method Evaluation

A calibration curve was established to determine CHA using UV-vis spectrophotometry, enabling the calculation of unknown sample concentrations from their measured absorbance values. Under the optimized experimental conditions, the method was validated in terms of linearity, LOD and LOQ. These performance characteristics are presented in Table 1. A series of CHA standard solution were prepared, yielding seven concentration points spanning a range from 0.1 to 2.0 mmol/L. Under the optimized experimental conditions, ΔA increased linearly with CHA concentration, as shown in Figure 4, with a correlation coefficient of 0.9918. The LOD and LOQ were calculated according to Formula (2). Taking into account that the extraction came from 0.5 g of cosmetics, the LOD and LOQ of the method were determined to be 0.007% and 0.02%, respectively. Furthermore, a convenient visual method for CHA detection was established. As shown in the inset of Figure 4, seven test tubes containing CHA standards at increasing concentrations were arranged sequentially, exhibiting a clear color gradient. This color change permits direct visual judgment of CHA presence and allows semi-quantitative estimation of its concentration in the test sample. It was worth noting that as the reaction time was prolonged, the sample color would change. Therefore, the visual readout should be completed as soon as possible.
Table 1. Performance of the present method for detecting CHA.
Figure 4. Linear calibration plot for CHA quantification based on the TMB-Fe3+ system. Experimental conditions: 15 mmol/L of HAc-NaAc solution, pH = 3.8, the temperature was 40 °C, the reaction times were 7 min and 5 min. Inset shows the photograph of the colored products for corresponding concentrations of CHA with the naked eye.

4.2. Recoveries

The proposed method was exploited to analyze CHA in various categories of cosmetics such as facial mask, cream, spray and toner. The cosmetic samples initially undergo pretreatment in which saturated NaCl solution was added for better dispersion of the solution. The recovery experiments were performed by adding CHA standard solution to the real samples before sample pretreatment. The recovery results are listed in Table 2. All values fell within the generally accepted validation range of 70–120%. The recoveries of toner and spray for the initially non-detectable samples ranged within 107.9%~117.5%. These elevated values suggested a potential matrix enhancement effect—components in the liquid formulations (e.g., alcohols, solvents, or surfactants) might slightly augment the chromogenic reaction, leading to a higher measured signal than expected. Alternatively, the low initial concentration (n.d.) magnified any minor proportional error in the measurement of the spiked sample. These values were still within a reasonable margin for a complex matrix at a low spike level and confirmed that CHA could be detected in such samples. The method could provide a simple and robust way for the detection of CHA in cosmetics.
Table 2. Recoveries for the determination of CHA in different kinds of cosmetics (n = 3).
Notably, cream-type matrices show lower recoveries, likely owing to the complex formulation. To mitigate this interference, several strategies can be further attempted: extracting CHA with an organic solvent followed by solvent exchange (via nitrogen blow-drying and reconstitution), applying additional cleanup procedures such as solid-phase extraction (SPE), or using matrix-matched calibration to correct matrix-induced deviations.

4.3. Selectivity Studies

The selectivity of the proposed method was evaluated separately for the first-step color development and the second-step fading reaction. For the first step, the catalytic activity of various inorganic elements, including Fe3+, Ag+, Pb2+, Hg2+, Cd2+, Cr2+, Zn2+, Ni2+, Se2+, Na+, Mg2+ and K+, was individually tested in the TMB-buffer system. As shown in Figure 5A, only Fe3+ was found to catalyze the oxidation of TMB, producing a blue color, whereas none of the other ions exhibited any color change, confirming their lack of catalytic activity in this reaction. Even the previously reported [38,39] Ag+ failed to develop blue color under these conditions, suggesting no interference occurred. In agreement with an earlier study [40], Fe3+ catalyzed TMB to generate a distinct blue color, serving as the foundation for this reaction system. The selectivity of the second-step fading reaction was also studied by testing six other traditional preservatives that are commonly used in cosmetics [41] under the same conditions. As shown in Figure 5B, the colorimetric tubes from left to right correspond to the systems containing buffer only, CHA, benzoic acid, sorbic acid, phenoxyethanol, dehydroacetic acid, triclocarban and methylisothiazolinone, respectively. A distinct color fading was observed only upon addition of CHA. In contrast, no significant color change occurred with the other preservatives. These results demonstrate the acceptable selectivity of the proposed method for detection of CHA in cosmetics.
Figure 5. Colorimetric responses of the proposed two-step system: (A) various metal ions for the first-step color-developing reaction, and (B) various preservatives for the second-step fading reaction. From left to right in panel B: 1, no preservative; 2, CHA; 3, benzoic acid; 4, sorbic acid; 5, phenoxyethanol; 6, dehydroacetic acid; 7, triclocarban; 8, methylisothiazolinone.
Potential interference from coexisting chelating agents (e.g., EDTA, citric acid) and endogenous Fe3+ in cosmetic matrices was also considered. Strong chelators may compete with CHA for Fe3+, leading to negative deviations, while intrinsic Fe3+ could generate background coloration and thus cause overestimation. Nevertheless, the chromogenic system contains Fe3+ in large excess relative to the possible levels of endogenous Fe3+ in real cosmetic products. More importantly, the stability constant of the Fe3+–CHA chelate is on the order of 1025, conferring CHA with an overwhelming competitive advantage over weaker chelators such as EDTA or citrate. In addition, two practical strategies could be employed to further minimize potential interference: (1) preparation of a sample blank to subtract the background absorbance from endogenous Fe3+, and (2) extraction of CHA into an organic solvent, which retains Fe3+ and hydrophilic chelators in the aqueous phase, thereby achieving effective separation of the target analyte from most interferents. Nevertheless, such strategies lead to more complex sample pretreatment operations, so they can be implemented only if more accurate quantification results are needed.
Therefore, despite possible theoretical interference, the proposed method is considered to exhibit acceptable selectivity for CHA detection in cosmetic matrices, particularly in its intended use as a rapid on-site screening tool. Its purpose is to improve regulatory efficiency by enabling quick identification of potentially non-compliant samples, which can then be confirmed by more sophisticated techniques such as HPLC or HPLC-MS/MS.

4.4. Possible Mechanism of the Two-Step Colorimetric Strategy

The developed two-step reaction strategy offers high selectivity through specific chemical reactions, with the possible mechanism shown in Figure 6. In the first step, Fe3+ oxidizes TMB under acidic conditions to form charge-transfer complexes or diimide structures accompanied by a characteristic blue color [35,40]. This reaction is reversible. Upon addition of CHA, which predominantly exists in its keto tautomeric form under acidic conditions, three CHA molecules strongly chelate one Fe3+ ion [33,34]. This chelation releases the diimide-form TMB, which is then converted back to colorless TMB, ultimately resulting in color fading. Thus, this competitive reaction—where CHA competes for Fe3+—triggers the fading response, enabling the detection of CHA in complex matrices.
Figure 6. Competitive chelation-mediated two-step colorimetric reaction mechanism.

4.5. Comparative Evaluation and Method Positioning

A comprehensive comparison between the proposed method and the reported HPLC-UV method [13] is presented in Table 3. HPLC-UV offers simultaneous multi-analyte detection (10 preservatives) with accurate quantification, yet it is time-consuming (30–60 min), operationally complex, expensive, and laboratory-bound. In contrast, our method targets a single analyte but provides a comparable or slightly better LOQ (0.012 vs. 0.015 mg/mL), shorter analysis time (15–30 min), simpler operation (no expertise needed), lower cost, and field portability. Therefore, the present method is well-suited as a rapid on-site pre-screening tool, complementing HPLC-UV for laboratory confirmation of suspicious samples [42].
Table 3. Comparison of two methods for CHA detection in cosmetics.
Green analytical chemistry focuses on making analytical procedures more environmentally benign and safer for humans. By referencing the 12 principles of green analytical chemistry, AGREE calculates a numerical score from 0 to 1 for analytical procedures and displays the result using a red-yellow-green pictogram. A score above 0.6 represents satisfactory environmental performance, with scores near 1 reflecting increasingly superior sustainability [43]. In this study, the developed method and the HPLC method were comprehensively assessed and calculated using AGREE software (https://mostwiedzy.pl/wojciech-wojnowski,174235-1/AGREE, accessed on 19 June 2026). As shown in Figure 7, the proposed method achieved an AGREE score of 0.76, whereas the HPLC method [13] scored 0.61, highlighting the excellent greenness of the developed procedure. Our approach fulfilled many aspects of the principles of green chemistry such as direct analytical techniques, minimal sample size, energy efficiency, simplified process, non-toxicity, environmental compatibility and operational safety.
Figure 7. Application of the AGREE approach to evaluate this proposed method (A) and the HPLC method (B), with the corresponding color scale for reference.

4.6. Practical Performance for Regulatory Application

For the purpose of verifying the practical utility of the proposed method, the concentrations of CHA in commercially available cosmetic products were determined. Cosmetic samples, including whitening cream, anti-acne facial mask, moisturizing spray and soothing toner, were collected, either labeled with CHA or unlabeled. The analytical results, including absorbance readings, calculated concentration, and the final content in the product, are presented in Table 4. CHA was successfully detected in an anti-acne facial mask and whitening cream. For these samples, a measurable decrease in absorbance was observed after the chromogenic reaction. The content in the original cosmetic was then calculated, yielding values of 0.21% and 0.23%. In contrast, for the spray and toner samples, the A was virtually identical to the blank absorbance (A0), resulting in a not-measured ΔA. It indicated the concentration of the CHA was below the LOD (0.007%). Therefore, these products were reported as not detected. The above detection results were in agreement with the CHA labeling indicated on the product packaging.
Table 4. Determination result of CHA in real samples (n = 3).
At present, no standardized analysis method has been issued for the quantitative detection of CHA in cosmetics worldwide, and the chromatographic conditions reported in the literature [13] lack unified specifications, making it difficult to establish a generally recognized reference system. Therefore, comparative experiments were not conducted in this study. In future research, a standardized HPLC protocol will be optimized, and large-scale comparative analysis will be implemented to further confirm the quantitative accuracy of the spectrophotometric method.
In major countries worldwide, compliance testing plays a vital role in the post-market regulation of cosmetics, verifying that target ingredient concentrations do not exceed regulatory limits and are consistent with product labeling [44,45]. In view of the current public emphasis on green chemistry, it remains to be further discussed whether this method can serve as a green technique for the regulation of cosmetics. As shown in Table 5, regulatory and historical usage limits for CHA differ geographically. Australia and South Korea enforce a 0.3% maximum permitted concentration for CHA, while China specifies a historical maximum usage level of 0.12%, and the United States records a historical upper limit of 0.3%. With an LOQ of 0.02%, the proposed spectrophotometric method is sufficiently sensitive to detect CHA well below all these thresholds, fully meeting regional compliance-monitoring needs. For the European Union, where no CHA regulatory limit is defined, this method enables effective routine screening to identify potential misuse or undeclared addition of CHA in cosmetics. Overall, the developed method possesses favorable sensitivity, greenness and wide applicability for CHA analysis under diverse global regulatory frameworks, supporting both official compliance testing and daily cosmetic surveillance.
Table 5. Method sensitivity and practical regulatory application.

5. Conclusions

As a common non-traditional preservative in cosmetics, the use of CHA has not been officially regulated by the European Union or Chinese authorities, raising the possibility of its misuse. To address this issue, this study leverages the strong chelation between CHA and Fe3+ and designs a two-step reaction to enable visual detection of CHA. The developed method features straightforward sample pretreatment, enables semi-quantitative analysis without specialized equipment, and provides accurate quantitative results for CHA in cosmetics using a simple spectrophotometer. In addition, the method showed favorable selectivity and accuracy in real sample detection. Beyond selective detection, this method is suitable for on-site rapid analysis of CHA in cosmetics and demonstrates good environmental friendliness, consistent with green chemistry concepts.

6. Patents

Patents (Grant No. CN 111795964 B) resulting from the work reported in this manuscript.

Author Contributions

Conceptualization, Y.D. and Y.W.; methodology, Y.D. and Y.Q.; validation, Q.Y.; formal analysis, Y.S. and L.L.; investigation, Y.D. and L.L.; data curation, Y.W. and Q.Y.; software: Y.D.,Y.Q. and Q.Y.; visualization: Y.D., Y.W. and Y.Q.; writing—original draft preparation, Q.Y. and Y.W.; writing—review and editing, Y.D. and Y.S.; supervision, Y.D. and Y.S.; project administration, Y.S.; funding acquisition and resources, Y.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by Gansu Provincial Science and Technology Program: (22YF7FA080); Gansu Provincial Key Talent Program: (2024RCXM49); Gansu Provincial Pharmaceutical Research Program: (2021GSMPA0014).

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The data used in this study are available upon reasonable request.

Acknowledgments

During the preparation of this manuscript, the author used Deepseek-V3 for the purposes of Language polishing. The authors have reviewed and edited the output and take full responsibility for the content of this publication.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Du, X.; He, Y.; Chen, Y.; Liu, Q.; Sun, L.; Sun, H.; Wu, X.; Lu, Y. Decoding Cosmetic Complexities: A Comprehensive Guide to Matrix Composition and Pretreatment Technology. Molecules 2024, 29, 411. [Google Scholar] [CrossRef] [Scilit]
  2. Chu, B.C.; Garcia-Herrero, A.; Johanson, T.H.; Krewulak, K.D.; Lau, C.K.; Peacock, R.S. Siderophore uptake in bacteria and the battle for iron with the host; a bird’s eye view. Biometals 2010, 23, 601–611. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Nasrollahi, S.S.; Moosavi, N.S.; Yamini, Y. Determination of parabens in different samples using green analytical chemistry approaches since 2015. TrAC Trends Anal. Chem. 2023, 166, 117163. [Google Scholar] [CrossRef] [Scilit]
  4. Ganeshpurkar, A.; Kumar, D.; Singh, S.K. Strategies for the synthesis of hydroxamic acids. Curr. Org. Synth. 2018, 15, 154–165. [Google Scholar] [CrossRef] [Scilit]
  5. Schraml, J. Derivatives of hydroxamic acids. Appl. Organomet. Chem. 2000, 14, 604–610. [Google Scholar] [CrossRef] [Scilit]
  6. Chowdhury, R.; Antolasic, F. Structural analysis of hydroxamate reagents by X-ray diffraction. J. Earth Sci. Eng. 2012, 2, 584. [Google Scholar]
  7. Ren, L.; Qiu, H.; Qin, W.; Zhang, M.; Li, Y.; Wei, P. Inhibition mechanism of Ca2+, Mg2+ and Fe3+ in fine cassiterite flotation using octanohydroxamic acid. R. Soc. Open Sci. 2018, 5, 180158. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Keth, J.; Johann, T.; Frey, H. Hydroxamic acid: An underrated moiety marrying bioinorganic chemistry and polymer science. Biomacromolecules 2020, 21, 2546–2556. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Muri, E.M.F.; Nieto, M.J.; Sindelar, R.D.; Williamson, J.S. Hydroxamic acids as pharmacological agents. Curr. Med. Chem. 2002, 9, 1631–1653. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Andrianov, V.; Gailite, V.; Lola, D.; Loza, E.; Semenikhina, V.; Kalvinsh, I. Novel amide derivatives as inhibitors of histone deacetylase: Design, synthesis and SAR. Eur. J. Med. Chem. 2009, 44, 1067–1085. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Ni, X.; Liu, Q. Notes on the adsorption of octyl hydroxamic acid on pyrochlore and calcite. Colloids Surf. A Physicochem. Eng. Asp. 2013, 430, 91–94. [Google Scholar] [CrossRef] [Scilit]
  12. Liu, M.; Li, H.; Jiang, T.; Liu, Q. Flotation of coarse and fine pyrochlore using octyl hydroxamic acid and sodium oleate. Miner. Eng. 2019, 132, 191–201. [Google Scholar] [CrossRef] [Scilit]
  13. Chen, T.; Chang, H. Deciphering trends in replacing preservatives in cosmetics intended for infants and sensitive population. Sci. Rep. 2024, 14, 19053. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Ackermann, L.; Virtanen, H.; Korhonen, L.; Laukkanen, A.; Huilaja, L.; Riekki, R. An epidemic of allergic contact dermatitis caused by a new allergen, caprylhydroxamic acid, in moisturizers. Contact Dermat. 2017, 77, 159–162. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Theret, V.; Burle, E.; Giordano, F. Caprylhydroxamic Acid: A Growing Allergen in Skincare Products. Contact Dermat. 2025, 93, 265–266. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Li, X.; Yang, T.; Tan, J.; Kuang, H.; Liang, W.; Peng, X. Nontarget screening and identification of emerging preservatives and their metabolites in human urine. J. Chromatogr. A 2025, 1760, 466322. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  17. Mesulam, M.-M. Tetramethyl benzidine for horseradish peroxidase neurohistochemistry: A non-carcinogenic blue reaction product with superior sensitivity for visualizing neural afferents and efferents. J. Histochem. Cytochem. 1978, 26, 106–117. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Huang, W.; Xie, Z.; Deng, Y.; He, Y. 3,3′,5,5′-tetramethylbenzidine-based quadruple-channel visual colorimetric sensor array for highly sensitive discrimination of serum antioxidants. Sens. Actuators B Chem. 2018, 254, 1057–1060. [Google Scholar] [CrossRef] [Scilit]
  19. Josephy, P.D.; Eling, T.; Mason, R.P. The horseradish peroxidase-catalyzed oxidation of 3,3′,5,5′-tetramethylbenzidine. Free radical and charge-transfer complex intermediates. J. Biol. Chem. 1982, 257, 3669–3675. [Google Scholar] [CrossRef] [Scilit]
  20. Volpe, G.; Draisci, R.; Palleschi, G.; Compagnone, D. 3,3′,5,5′-Tetramethylbenzidine as electrochemical substrate for horseradish peroxidase based enzyme immunoassays. A comparative study. Analyst 1998, 123, 1303–1307. [Google Scholar] [CrossRef] [Scilit]
  21. Huang, L.; Cao, Y.-J.; Sun, X.-Y.; Liu, B.; Shen, J.-S. Diverse applications of TMB-based sensing probes. Org. Biomol. Chem. 2018, 16, 5667–5676. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. Liu, J.; Wu, F.; Liu, C.; Bao, H.; Fu, T. “Turn-on” fluorometric probe for α-glucosidase activity using red fluorescent carbon dots and 3,3′,5,5′-tetramethylbenzidine. Microchim. Acta 2020, 187, 498. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Liu, D.-M.; Dong, C.; Ma, R.-T. A colorimetric method for screening α-glucosidase inhibitors from flavonoids using 3,3′,5,5′-tetramethylbenzidine as a chromogenic probe. Colloids Surf. B Biointerfaces 2021, 197, 111400. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  24. Qian, R.; Gao, D.; Liu, L.P.; Jiang, Y.Y. Colorimetric glucose sensing with multiple-color changes by using a MnO2 NSs-TMB nanosystem. Anal. Methods 2021, 13, 769–775. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  25. Niu, X.; Cheng, N.; Ruan, X.; Du, D.; Lin, Y. Nanozyme-based immunosensors and immunoassays: Recent developments and future trends. J. Electrochem. Soc. 2020, 167, 037508. [Google Scholar]
  26. Lee, G.-Y.; Park, J.-H.; Chang, Y.W.; Cho, S.; Kang, M.-J.; Pyun, J.-C. Chronoamperometry-based redox cycling for application to immunoassays. ACS Sens. 2018, 3, 106–112. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  27. Wang, J.; Wang, J.; Zhou, P.; Tao, H.; Wang, X.; Wu, Y. Oligonucleotide-induced regulation of the oxidase-mimicking activity of octahedral Mn3O4 nanoparticles for colorimetric detection of heavy metals. Microchim. Acta 2020, 187, 99. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  28. Jang, G.-G.; Roper, D.K. Balancing redox activity allowing spectrophotometric detection of Au(I) using tetramethylbenzidine dihydrochloride. Anal. Chem. 2011, 83, 1836–1842. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Singh, S.; Mitra, K.; Shukla, A.; Singh, R.; Gundampati, R.K.; Misra, N. Brominated graphene as mimetic peroxidase for sulfide ion recognition. Anal. Chem. 2017, 89, 783–791. [Google Scholar] [PubMed]
  30. Dong, Y.; Qiao, Y.; Yuan, Y.; Wang, H.; Sun, L.; Ren, C. Rapid and visual detection of benzoyl peroxide in cosmetics by a colorimetric method. Chem. Pap. 2023, 77, 2151–2160. [Google Scholar] [CrossRef] [Scilit]
  31. Lin, M.; Guo, Y.; Liang, Z.; Zhao, X.; Chen, J.; Wang, Y. Simple and fast determination of biothiols using Fe3+-3,3′,5,5′-tetramethylbenzidine as a colorimetric probe. Microchem. J. 2019, 147, 319–323. [Google Scholar] [CrossRef] [Scilit]
  32. Zhang, B.; Zhong, H. Determination of hydroxamic acids by direct spectrophotometry of colored complex in acidic solution. Res. Chem. Intermed. 2010, 36, 495–501. [Google Scholar] [CrossRef] [Scilit]
  33. Gillam, A.; Lewis, A.; Andersen, R. Quantitative determination of hydroxamic acids. Anal. Chem. 1981, 53, 841–844. [Google Scholar] [CrossRef] [Scilit]
  34. Agrawal, Y. Hydroxamic acids and their analytical applications. Rev. Anal. Chem. 1980, 5, 3–28. [Google Scholar] [CrossRef] [Scilit]
  35. Su, L.; Feng, J.; Zhou, X.; Ren, C.; Li, H.; Chen, X. Colorimetric detection of urine glucose based ZnFe2O4 magnetic nanoparticles. Anal. Chem. 2012, 84, 5753–5758. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  36. Li, X.; Kong, C.; Chen, Z. Colorimetric sensor arrays for antioxidant discrimination based on the inhibition of the oxidation reaction between 3,3′,5,5′-tetramethylbenzidine and hydrogen peroxides. ACS Appl. Mater. Interfaces 2019, 11, 9504–9509. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. Di, Y.; Zheng, J.; Zhao, Y.; Yang, Z.; Xie, C.; Yu, J.; Zheng, Y.; Gao, L. Colorimetric/photothermal dual-mode sensing detection of ascorbic acid based on a Ag(I) ion/3,3′,5,5′-tetramethylbenzidine (TMB) system. RSC Adv. 2022, 12, 36012–36017. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  38. Shu, X.; Chen, Y.; Yuan, C.; Wang, Y. Ag+-3,3′,5,5′-tetramethylbenzidine as a probe for colorimetric detection of ascorbic acid in beverages. New J. Chem. 2020, 44, 1772–1776. [Google Scholar] [CrossRef] [Scilit]
  39. Ni, P.; Sun, Y.; Dai, H.; Hu, J.; Jiang, S.; Wang, Y.; Li, Z. Highly sensitive and selective colorimetric detection of glutathione based on Ag(I) ion-3,3′,5,5′-tetramethylbenzidine (TMB). Biosens. Bioelectron. 2015, 63, 47–52. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  40. Zhang, L.; Du, J. Selective sensing of submicromolar iron(III) with 3,3′,5,5′-tetramethylbenzidine as a chromogenic probe. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 2016, 158, 24–28. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  41. Poddębniak, P.; Kalinowska-Lis, U. A Survey of Preservatives Used in Cosmetic Products. Appl. Sci. 2024, 14, 1581. [Google Scholar] [CrossRef] [Scilit]
  42. Sentana, P.A.; Denny, H.M.; Susanto, H.S. Health Safety in Cosmetics Industries: A Case Study of Evaluation on Physical Environmental Safety. Int. J. Sci. Res. 2019, 8, 685–689. [Google Scholar]
  43. Pena-Pereira, F.; Wojnowski, W.; Tobiszewski, M. AGREE Analytical GREEnness Metric Approach and Software. Anal. Chem. 2020, 92, 10076–10082. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  44. Rahmawati, E.; Huda, M.; Aldhi, I.F. Legal Liability of Business Operators for Beauty Products Containing Hazardous Chemicals. J. Law Polit. Humanit. 2024, 4, 334–343. [Google Scholar] [CrossRef] [Scilit]
  45. Krawiec, K.D. Cosmetic compliance and the failure of negotiated governance. Wash. Univ. Law Q. 2003, 81, 487. [Google Scholar]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.