Abstract
Bacterial contaminants in ambulances could have a major impact on morbidities, mortalities, and healthcare resources, especially if these bacteria are antimicrobial-resistant. As far as we know, this is the first study in Al-Qassim region to evaluate the prevalence of bacterial contaminants in swab samples obtained from ambulances from Alqwarah General Hospital, Al-Qassim region, Saudi Arabia as an indicator for evaluation of the implemented infection control measures, and screen the antibiotics profiles of the isolates against the most regularly used antimicrobials. In total, 204 samples were collected from the ambulances following patient transport. To evaluate the effect of vehicle decontamination, 204 swabs were collected from the same sites of the ambulances immediately after cleaning and disinfection. The isolates were identified using standard bacteriological and biochemical methods, as recommended by the Clinical Laboratory Standard Institute (CLSI). The antibiotic susceptibility patterns were assessed using the Kirby–Bauer disc diffusion method. The prevalence of bacterial contamination in the samples collected following patient transport was 46.08%. In total, 83.33%, 75.00%, and 66.66% of the samples collected from DC shock apparatuses, ceilings, and emergency personnel seats, respectively, were contaminated. Furthermore, ceilings, DC shock apparatuses, emergency personnel seats, cervical collars, and monitors were found to harbor 10.8%, 9.8%, 7.8%, 6.8%, and 6.8% of the 102 bacterial isolates, respectively. Gram-positive organisms represented 96.1% of all bacterial isolates. Bacillus spp. was the most common isolate, accounting for 60.8% of all bacterial isolates. Although Pseudomonas aeruginosa and Proteus spp. isolates were sensitive to all the tested antimicrobials, many Gram-positive bacterial isolates were resistant to some antibiotics in variable frequencies. After 48 h of aerobic incubation (with or without 5–10% CO2) on nutrient, blood, chocolate, and MacConkey agar plates at 37 °C, no bacterial growth was detected in the samples collected immediately following cleaning and disinfection. This is the second Saudi study to evaluate the prevalence of bacterial contaminants in Saudi Arabian ambulances, and it could help health policy makers in improving the implemented infection prevention and control measures in Saudi Arabian ambulances. The samples taken after patient transport revealed bacterial contaminants with varying rates of antimicrobial resistance. Policies ensuring the optimal cleaning and disinfection of ambulances can minimize the potential of bacterial infection for high-risk patients, their relatives, and healthcare providers.
1. Introduction
The ambulances utilized by emergency medical care teams are workplaces for qualified medical and paramedical staff who oversee daily transportation for patients in life-threatening conditions from all walks of life with a variety of infections, diseases, and injuries. Millions of seriously ill and injured patients are transported to and from hospitals and other healthcare (HC) facilities by emergency medical services (EMS) personnel, who are frequently referred to as the “front lines” of the HC system. EMS providers frequently encounter a wide range of hazardous and erratic circumstances while carrying out their jobs, endangering both their own and their patients’ safety. EMS personnel are up to seven times more likely to suffer harm at work [1].
Numerous surfaces, including the patient-care compartments of ambulances, around the world have been found to harbor the organisms most frequently linked to healthcare-associated infections (HAIs). The complexity of addressing the accompanying infections makes organisms detected in ambulance environments problematic, especially if they are of a multidrug resistant (MDR) nature. Emergency care frequently involves people in life-threatening situations. When using ambulance services, vulnerable groups such as the old, young, immunocompromised, and seriously injured are frequently treated concurrently. Therefore, transport vehicles may be potential sources of transmission of microbes to high-risk patients, their relatives, and HC providers [2]. By encountering infected patients and their body fluids, as well as by visiting a variety of locations throughout their shifts (such as homes, workplaces, and hospitals), EMS providers are probably regularly exposed to biohazard threats from microorganisms [3].
According to the World Health Organization (WHO), millions of HAIs occur annually, affecting around 7% and up to 19% of patients in developed and developing countries, respectively [4]. According to the American Centers for Disease Control and Prevention (CDC), many bacteria, viruses, and/or fungi can cause HAIs, but special attention has been paid to the organisms that are highly contagious, exhibit high virulence, or are resistant to common antimicrobials. MDR bacteria are of particular concern because they can cause serious and challenging-to-treat HAIs [5]. Bacterial contaminants in ambulances could have a major impact on morbidities, mortalities, and HC resources, especially if these bacteria are MDR. Thus, ambulances may pose a risk of serious infection to patients, their relatives, HC providers, and paramedics [2,3].
Bacterial contamination of ambulances has been the subject of numerous studies worldwide [6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25]. Bacillus species (spp.) have been reported in many countries, including the UK [6], the USA [7], Saudi Arabia [14], and Spain [19]. In the UK, micrococci have been detected among ambulances’ bacterial contaminants [6]. In the UK [6], the USA [7], South Korea [10,12], Iraq [13], Spain [19], Denmark [20], Egypt [21], Iran [23], and India [24], Gram-negative bacterial contaminants have been isolated. Staphylococci were detected in UK [6], USA [7,8,11,22], Germany [9,16], South Korea [10,12], Saudi Arabia [14], Thailand [15], Australia [17], Denmark [18,20], Spain [19], Egypt [21], Iran [23], India [24], and Poland [25].
The family Firmicutes contains the genus Bacillus, which is composed of aerobic, facultative anaerobic, Gram-positive spore-forming bacilli with low GC content. The amount of vegetation, mean annual temperature, soil moisture content, and pH all have an impact on the abundance of Bacillus spores in the soil. Numerous pathogenic and non-pathogenic Bacillus spp. are frequently found in soil [26]. Micrococci are spherical, Gram-positive, coagulase-negative, catalase-positive cocci that are frequently seen in tetrads and are members of the Micrococcaceae family. Micrococcus species are frequently found in the environment and can cause opportunistic infections in people with impaired immune systems [27]. Moraxella is an aerobic, oxidase-positive, Gram-negative diplococcus that is often considered a potentially pathogenic genus, particularly in immunocompromised people [28]. The prevalence of bacteria, including staphylococci, in ambulances highlights the importance of maintaining high hygiene and decontamination standards during regular prehospital work with patients [6].
Infection or colonization with MDR organisms found in ambulances increases the probability of complications. Given the frequency of organisms often linked to HAIs in the patient-care compartments of ambulances, it is obvious that the best decontamination compliance procedures are not always followed [2]. The contribution of EMS vehicles and equipment to the epidemiological transmission of HAIs both inside and outside the HC industry requires further research. As far as we are aware, there is just one study looking at the bacterial contamination of Saudi Arabian ambulances [14]. In this prospective, our study aims were to determine the prevalence of bacterial contaminants in the ambulances used at Alqwarah General Hospital in the Al-Qassim region of Saudi Arabia and to assess the isolates’ antibiotic profiles against the most-used antimicrobials as indicators for evaluating the effectiveness of the infection control strategies that were put in place.
2. Materials and Methods
2.1. Design of the Study
Bioethical approval (no. 607-46-010690) was obtained from the Qassim Region Research Ethics Committee (QREC; No. H-04-Q-001), Qassim, Saudi Arabia. According to the inclusion criteria, we included ambulances that were regularly used for transfer of patients, ambulances whose drivers were unaware of when sampling visits would be conducted, and ambulances whose drivers agreed to cooperate. We excluded ambulances that were out of service, ambulances whose drivers previously knew when sampling visits would be conducted, and ambulances whose driver refused to cooperate.
Swab samples were collected from different sites of two ambulances at Alqwarah General Hospital, Al-Qassim region, Saudi Arabia, in a cross-sectional study during April and May 2025. The privacy and confidentiality of those responsible for the ambulances were protected. Processing of the samples was performed in the microbiology laboratory of the Department of Medical Laboratories, College of Applied Medical Sciences, Qassim University, Buraydah City 51452, Saudi Arabia, after obtaining the required permissions.
2.2. Collection and Transport of Samples
The required sample size for each of the two ambulances was estimated using the following formula: n = (Z2 × p(1 − p))/d2, where n = sample size, Z = Z-score corresponding to the desired confidence level (Z = 1.96 when confidence level = 95%), p = the estimated proportion of contamination (a conservative estimate was used: p = 0.5), and d = desired margin of error (we used a margin of error of 0.1) [29]. Thus, the estimated sample size for each ambulance was 96 swabs. In total, 204 samples were collected from different sites of two ambulances following patient transport (17 swabs were collected from each ambulance in six sampling visits).
We used sterile cotton-tipped swabs with amies transport media (GlobalRoll®, Hangzhou, China). The sampling sites were as follows: carrying handle of cart, sidebar of cart, DC shock apparatus, stethoscope, cervical collar, inside wall of vehicle, emergency personnel seats, portable ventilator, blood pressure cuff, monitor, door grip, oxygen humidifier glass, suction device, headboard of patient stretcher, and steering wheel. The sterile swabs, which had been moistened with the transport media, were rolled over all the selected surfaces.
To evaluate the effect of vehicle decontamination, 204 swabs were collected from the same sites of the ambulances immediately after cleaning and disinfection. Standard bleach (sodium hypochlorite solution, 10,000 parts per million; normal dilution, 1:10) was the main disinfectant that was used, especially for blood spills and external surfaces. Alcohol (70–95%) was used for external surfaces of certain pieces of equipment, including stethoscopes and pulse oximeters. For walls, floors, and furnishings, quaternary ammonium compounds or hydrogen peroxide was used.
Each sample was collected in a sterile bag and carried in an icebox to be processed according to the standard microbiological methods in the microbiology laboratory of the Department of Medical Laboratories, College of Applied Medical Sciences, Qassim University after the required permissions were obtained.
2.3. Isolation and Identification of Bacteria
To avoid contamination, the samples were handled aseptically upon arrival. All media used in this study were prepared according to the manufacturer’s guidelines. The swabs were placed in tubes containing five milliliters of double-strength brain–heart infusion broth (Oxoid, Hampshire, UK) and incubated (with or without 5–10% CO2) aerobically at 37 °C for 24 h. After enrichment, the swabs were cultured on nutrient, blood, chocolate, and MacConkey agar plates (Oxoid, Hampshire, UK) and incubated (with or without 5–10% CO2) aerobically at 37 °C for an additional 48 h. To isolate pure single colonies of each bacterial isolate, the colonies were further subcultured on these agar plates under the same conditions for another 24 h. Following this, the pure colonies were analyzed using standard microbiological techniques, which included examining colony morphology (size, color, and shape), performing Gram staining, and conducting biochemical tests [30].
2.4. Antibiotic Sensitivity Testing
The antibiotic susceptibilities patterns of the bacterial isolates were assessed via the Kirby–Bauer disc diffusion method according to the guidelines of the clinical and laboratory standards institute (CLSI) [31]. The Gram-positive bacterial isolates were tested against the following antimicrobials: AP—Ampicillin, 10 μg; AK—Amikacin, 30 μg; AUG—Augmentin, 30 μg; BA—Bacitracin, 10 U; C—Chloramphenicol, 30 μg; CAZ—Ceftazidime, 30 μg; CIP—Ciprofloxacin, 5 μg; CD—Clindamycin, 2 μg; CPM—Cefepime, 30 μg; E—Erythromycin, 15 μg; FOX—Cefoxitin, 30 μg; GM—Gentamicin, 10 μg; Imipenem, 10 μg; KF—Cephalothin, 30 μg; NE—Neomycin, 30 μg; OT—Oxytetracycline, 30 μg; OX—Oxacillin, 5 μg; PG—Penicillin G, 10 U; PRL—Piperacillin, 30 μg; T—Tetracycline, 30 μg; TS—Cotrimoxazole, 25 μg; and VA—Vancomycin, 30 μg. The Gram-negative bacterial isolates were tested against the following antimicrobials: AP—Ampicillin, 10 μg; AK—Amikacin, 30 μg; ATM—Aztreonam, 30 μg; AUG—Augmentin, 30 μg; C—Chloramphenicol, 30 μg; CAZ—Ceftazidime, 30 μg; CIP—Ciprofloxacin, 5 μg; CPM—Cefepime, 30 μg; FOX—Cefoxitin, 30 μg; GM—Gentamicin, 10 μg; Imipenem, 10 μg; KF—Cephalothin, 30 μg; NE—Neomycin, 30 μg; PRL—Piperacillin, 30 μg; PB—Polymyxin B, 300 U; and TS—Cotrimoxazole, 25 μg.
2.5. Quality Control (QC)
ATCC strains (Staphylococcus aureus; ATCC25923 as QC for Gram-positive isolates; and Escherichia coli ATCC10536 as QC for Gram-negative isolates) were used as positive controls. QC testing was carried out in triplicate. Each isolate was tested in triplicate. The study’s negative controls for bacterial culture were non-inoculated nutrient, blood, chocolate, and MacConkey agar plates incubated (with or without 5–10% CO2) aerobically at 37 °C for 48 h. All data were evaluated using CLSI’s guidelines [31].
2.6. Data Analysis
Categorical data was presented as numbers and percentages. The total bacterial contamination prevalence rate was determined from the number of growth-positive swabs at the time the study was conducted divided by the number of all collected swabs. Each sampling site’s bacterial contamination prevalence was tested statistically by using the Chi-square (X2) test to compare the likelihood of an event (bacterial contamination) occurring between two groups (growth-positive/growth-negative swabs). Alternatively, the Fisher Exact (FE) correction test was applied when more than 20% of the cells had an expected count of less than 5. Statistical significance was considered at p ≤ 0.05.
3. Results
During the study, different samples were collected from the ambulances used by Alqwarah General Hospital, Al-Qassim region, Saudi Arabia. A total of 204 samples were collected following patient transport. Under suitable incubation conditions, samples were processed and grown on suitable media. Bacterial contaminants were detected (94 bacterial-growth-positive swabs/204 samples collected from the ambulances after the patients had been transported—46.08%). Out of the 94 swabs with positive bacterial growth, 86 samples revealed a single pathogen, while 8 samples revealed two pathogens. As a result, the overall count of bacterial isolates was 102.
The frequency of positive bacterial growth from each site of each vehicle is presented in Table 1. It is clear that 83.33%, 75.00%, and 66.66% of the samples collected from DC shock apparatuses, ceilings, and emergency personnel seats, respectively, were contaminated. Statistically, it is clear that the DC shock apparatuses and ceilings have a greater probability of being contaminated (p ≤ 0.05). Furthermore, the frequency of bacterial isolates in each site of each ambulance is presented in Table 2. In total, 10.8%, 9.8%, 7.8%, 6.8%, and 6.8% of the bacterial isolates were recovered from the ceilings of the ambulances, DC shock apparatuses, emergency personnel seats, cervical collars, and monitors, respectively.
Table 1.
Frequencies of positive bacterial growth from each site of the ambulance vehicles based on the samples collected following patient transport.
Table 2.
Frequencies of bacterial isolates in each site of ambulances based on the samples collected following patient transport.
The distribution of bacterial isolates on each site in the ambulances is presented in Table 3. It is clear that Gram-positive organisms represent 96.1% of all the bacterial isolates (98 Gram-positive/102 total isolates). Bacillus spp. was the most common isolate, accounting for 60.8% of all the bacterial isolates (62 Bacillus spp./102 total isolates), followed by Micrococcus spp., which represented 30.4% of the total bacterial isolates. The Gram-negative isolates only represented 3.9% of the total bacterial isolates.
Table 3.
Distribution of bacterial isolates on each site in the ambulances, as derived from the samples collected following patient transport.
Regarding the antimicrobial resistance patterns of the Gram-positive bacterial isolates, variable frequencies of resistance to some antibiotics were detected, as presented in Table 4. The control strain S. aureus ATCC25923 was susceptible to the tested antimicrobial. The Gram-negative bacterial isolates were tested against many antimicrobials. Fifty percent of the Moraxella isolates were resistant to cotrimoxazole and cephalothin antimicrobials. The isolates of Moraxella were susceptible to the remaining antibiotics, while the Pseudomonas aeruginosa and Proteus spp. isolates were sensitive to all the tested antibiotics. The control strain, E. coli ATCC10536, was susceptible to the tested antimicrobials.
Table 4.
Antimicrobial resistance patterns of Gram-positive bacterial isolates, as derived via disc diffusion method. Data shown are frequencies (n (%)).
Concerning the samples collected from the ambulances immediately following cleaning and disinfection, no bacterial growth was detected after 48 h of aerobic incubation (with or without 5–10% CO2) on nutrient, blood, chocolate, or MacConkey agar plates blood agar plates at 37 °C.
4. Discussion
Bacterial contaminants found in ambulances must be further isolated and characterized to be properly prevented and controlled. In this prospective study, we aimed to determine the prevalence of bacterial contaminants in swab samples obtained from ambulances used by Alqwarah General Hospital, Al-Qassim region, Saudi Arabia as an indicator for evaluating the implemented infection prevention and control measures, and screen the isolates’ antibiotics profiles for the most regularly used antimicrobials. The bacterial contamination prevalence in the samples collected following patient transport was 46.08%. The ambulances’ ceilings, DC shock apparatuses, and emergency personnel seats were the most common sites for bacterial contaminant detection.
Variable bacterial contamination rates have been reported in many countries, including the United Kingdom, the USA, Germany, South Korea, Iraq, Saudi Arabia, Thailand, Australia, Denmark, Spain, Egypt, Iran, India, and Poland [6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25], with great variability in isolate types, and the highly contaminated sites are presented in Appendix A Table A1. To our knowledge, only one prior Saudi study has examined bacterial contamination in ambulances in Saudi Arabia. This research was carried out at the EMS Department of Prince Sultan Bin Abdulaziz College of EMS at King Saud University in Riyadh, Saudi Arabia, in October and November 2013, involving a total of 10 ambulances. The study reported a 90.00% total ambulance bacterial contamination rate (100%, 90%, and 80% contamination rates of the interior handle of the rear door, oxygen knobs, and stretcher handles, respectively) [14].
It was evident from the distribution of bacterial isolates on each ambulance site in our study that 96.1% of all the bacterial isolates were Gram-positive species. Accounting for 60.8% of all bacterial isolates, Bacillus spp. were the most prevalent, followed by Micrococcus spp., which accounted for 30.4% of all the bacterial isolates. Only 3.9% of the detected total bacterial contaminants were Gram-negative isolates. Although Pseudomonas aeruginosa and Proteus spp. isolates were sensitive to all the antimicrobials tested, many Gram-positive bacterial isolates were resistant to some antibiotics at variable frequencies. In line with our study, great variabilities in the bacterial contaminants of ambulances and their sensitivity/resistance to antimicrobials reported were in [6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25], as presented in Appendix A Table A1. The predominance of Gram-positive bacterial isolates was clear in a previous Saudi Arabian study in which Bacillus spp. and coagulase negative staphylococci were the top two detected bacterial contaminants [14]. Bacillus spp. can be transmitted via air currents, especially during hot, dry summer months [32], as in many Saudi regions. Bacillus spp. have been reported in other countries too, including the UK [6], the USA [7], and Spain [19].
To assess safety, microbiological standards that include the presence of indicator organisms can be implemented. Identifying these organisms helps determine potential risks to human health in HC settings. Staphylococcus aureus can be considered a reliable indicator of environmental hygiene [33]. While Staphylococcus aureus was not detected among the isolates in our study, it has been detected in the UK [6], the USA [8,11,22], Germany [9,16], South Korea [10,12], Thailand [15], Australia [17], Denmark [18,20], Spain [19], Egypt [21], India [24], and Poland [25].
The variability in the contamination rates of ambulances, their highly contaminated sites, and the types of bacterial isolates can be attributed to several factors, including the nature of emergency calls (for example, a trauma call may introduce more pathogens than non-emergency calls), patient demographics (including age and health status, as some people may carry higher bacterial loads), variations in decontamination practices (cleaning and disinfection protocols, equipment, and frequency of decontamination), and environmental conditions. Environmental factors such as urban density, pollution levels, and environmental temperature can influence the bacterial load present on surfaces. While it is conceivable that the intense heat typical of Saudi Arabia’s environment could serve as a defense against certain infections, it was clearly demonstrated in both our study and the earlier Saudi research that Bacillus spp. can resist hot atmospheres. The different types of materials utilized in an ambulance’s interior, which may retain bacteria to variable degrees, can also have an impact on contamination levels, as can seasonal bacterial fluctuations and high passenger turnover. These discrepancies are further exacerbated by the infrastructure of HC facilities in particular regions and the existence of microbial resistance, underscoring the necessity of using focused approaches to enhance the EMS’ infection prevention and control regulations.
The bacteria associated with HAIs possess two notable characteristics. They not only cause illness but also can persist in hospital environments for weeks. It is essential to ensure that pathogens are not present on surfaces in HC settings to maintain safety for both patients and HC workers. Important bacteria to steer clear of in these environments include Methicillin-resistant Staphylococcus aureus (MRSA), Vancomycin-resistant Enterococci (VRE), Clostridium difficile, and Acinetobacter. While Gram-negative coliforms, such as E. coli and Klebsiella spp., are not as resilient, they can survive on both dry and wet surfaces, albeit for shorter durations compared to the more durable Acinetobacter and Gram-positive bacteria mentioned earlier [32].
The results of our study show that no bacterial growth was detected in the samples taken from the ambulances immediately after they were cleaned and disinfected, suggesting that efficient infection prevention and control measures were implemented. Alqwarah General Hospital in Al-Qassim region, Saudi Arabia, implements the EMS infection control guidelines of the Saudi Ministry of health [34]. Briefly, these infection prevention and control guidelines include patient transfer recommendations; immunization programs; tuberculosis screening guidelines for EMS providers; an EMS provider fitness test and basic infection control skills license (BICSL); a patient isolation guide for EMS transport; standard precautions; hand hygiene; personal protective equipment (PPE), cleaning and disinfection for vehicle equipment, patient contact surfaces, and ambulance surfaces, as presented in Table 5 and Table 6; continuous availability of supplies; and education, training, compliance, and monitoring for EMS providers. Furthermore, the infection control practices are audited using a checklist for the cleaning and disinfection of the ambulances.
Table 5.
Recommendations for ambulance decontamination (cleaning and disinfection) following patient transport according to the Saudi Ministry of Health infection control guidelines [34].
Table 6.
Recommended ambulance disinfectants according to the Saudi Ministry of Health infection control guidelines [34].
Aerobic colony counts of less than 2.5 to 5 colony-forming units per cm2 on surfaces frequently touched by hands are recognized as microbiological standards for surfaces inside hospitals [35]. Although achieving a completely sterile environment is unrealistic, the objective is to reduce the number of harmful microorganisms on ambulance surfaces to safeguard patients and HC providers. It is essential to set an appropriate benchmark for regular microbiological monitoring of surface cleanliness in ambulances. Once these benchmarks are in place, ongoing microbiological monitoring can reveal trends in ambulance cleanliness and workload and, most importantly, signal when additional cleaning is necessary to prevent potential infections. Adhering to best practices for cleaning and disinfecting EMS vehicles and patient care equipment is crucial for controlling the spread of infections.
Among the limitations of our study were the small sample size (204 swabs) and the fact that the swab samples were only collected from a single medical center. Furthermore, we did not evaluate seasonal bacterial fluctuations. Nonetheless, we focused on a crucial issue and think we have enough data to achieve our goal and support our findings. Despite these limitations, our work emphasizes the necessity of further investigation into the bacteria that frequently result in HAIs via ambulance environments.
5. Conclusions and Recommendations
To the best of our knowledge, this is the second Saudi study to evaluate the prevalence of bacterial contaminants in swab samples obtained from Saudi Arabian ambulances, and it could help health policy makers in improving the infection prevention control measures implemented in Saudi Arabian ambulances. The swab samples collected from the ambulances after the patients were transported revealed bacterial contaminants with varying degrees of reduced antimicrobial susceptibility. Ambulance environments can be sources of HAIs. No bacterial contaminants were detected after proper cleaning and disinfection. Optimal infection control measures, including effective policies for cleaning and disinfecting ambulances, can minimize the potential of bacterial infection for high-risk patients, their relatives, and HC providers. Our study underscores the need for more widespread and in-depth studies of the ambulance microbiome as an important pathogen reservoir for HAIs. It is essential to establish a suitable benchmark for routine microbiological surveillance of ambulance surface safety.
Author Contributions
Conceptualization, A.E.T.; data curation, A.E.T., A.R.A. and A.M.K.; formal analysis, A.E.T., A.R.A. and A.M.K.; investigation, A.E.T., A.R.A. and A.M.K.; methodology, A.E.T.; project administration A.E.T.; resources, A.E.T., A.R.A., O.N.A., A.M.K., A.A., S.A., A.N.A., M.A., K.A. and F.M.A.; software, A.E.T., A.R.A., O.N.A., A.M.K., A.A., S.A., A.N.A., M.A., K.A. and F.M.A.; supervision, A.E.T.; validation, A.E.T., A.R.A. and A.M.K.; visualization, A.E.T., A.R.A., O.N.A., A.M.K., A.A., S.A., A.N.A., M.A., K.A. and F.M.A.; writing—original draft, A.E.T. and A.R.A.; writing—review and editing, A.E.T. All authors have read and agreed to the published version of the manuscript.
Funding
The authors declare that they did not receive any financial support for this research.
Institutional Review Board Statement
The study was conducted in accordance with the Decla-ration of Helsinki and approved by the Qassim Region Research Ethics Committee (QREC; No. H-04-Q-001), Qassim, Saudi Arabia (Bioethical approval no. 607-46-010690, approved on 12 March 2025).
Informed Consent Statement
Written informed consent was obtained from the supervisors of the ambulances used in the study. All data were anonymized to ensure confidentiality.
Data Availability Statement
The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding authors.
Acknowledgments
We are very thankful for the administration of Alqwarah General Hospital, Ministry of Health, Alqassim province, Buraydah City 51452, Saudi Arabia, for facilitating the work of the research team during sample collection. We appreciate the support of the administration of the Department of Medical Laboratories, College of Applied Medical Sciences, Qassim University, Buraydah City 51452, Saudi Arabia, during our use of their microbiology facilities.
Conflicts of Interest
The authors declare that there are no conflicts of interest.
Appendix A
Table A1.
Previous studies reporting bacterial contamination in ambulances.
References
- Roberts, M.H.; Sim, M.R.; Black, O.; Smith, P. Occupational injury risk among ambulance officers and paramedics compared with other healthcare workers in Victoria, Australia: Analysis of workers’ compensation claims from 2003 to 2012. Occup. Environ. Med. 2015, 72, 489–495. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Obenza, A.; Cruz, P.; Buttner, M.; Woodard, D. Microbial contamination on ambulance surfaces: A systematic literature review. J. Hosp. Infect. 2022, 122, 44–59. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hudson, A.J.; Glaister, G.D.; Wieden, H.J. The Emergency Medical Service Microbiome. Appl. Environ. Microbiol. 2018, 84, e02098-17. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
- World Health Organization (WHO). Report on the Burden of Endemic Health Care-Associated Infection Worldwide; World Health Organization: Geneva, Switzerland, 2011; Available online: http://apps.who.int/iris/bitstream/10665/80135/1/9789241501507_eng.pdf (accessed on 15 November 2025).
- Centers for Disease Control and Prevention (CDC). Antibiotic Resistance Threats in the United States, 2013 (Report CS239559-B); Centers for Disease Control and Prevention: Atlanta, GA, USA, 2013. Available online: https://www.cdc.gov/antimicrobial-resistance/media/pdfs/ar-threats-2013-508.pdf (accessed on 15 November 2025).
- Nigam, Y.; Cutter, J. A preliminary investigation into bacterial contamination of Welsh emergency ambulances. Emerg. Med. J. 2003, 20, 479–482. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
- Galtelli, M.; Deschamp, C.; Rogers, J. An assessment of the prevalence of pathogenic microorganisms in the rotor wing ambulance: One program’s findings. Air Med. J. 2006, 25, 81–84. [Google Scholar] [CrossRef] [Scilit]
- Brown, R.; Minnon, J.; Schneider, S.; Vaughn, J. Prevalence of methicillin-resistant Staphylococcus aureus in ambulances in southern Maine. Prehospital Emerg. Care 2010, 14, 176–181. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Eibicht, S.J.; Vogel, U. Meticillin-resistant Staphylococcus aureus (MRSA) contamination of ambulance cars after short term transport of MRSA-colonised patients is restricted to the stretcher. J. Hosp. Infect. 2011, 78, 221–225. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Noh, H.; Shin, S.D.; Kim, N.J.; Ro, Y.S.; Oh, H.S.; Joo, S.I.; Kim, J.I.; Ong, M.E. Risk stratification-based surveillance of bacterial contamination in metropolitan ambulances. J. Korean Med. Sci. 2011, 26, 124–130. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
- Rago, J.V.; Buhs, L.K.; Makarovaite, V.; Patel, E.; Pomeroy, M.; Yasmine, C. Detection and analysis of Staphylococcus aureus isolates found in ambulances in the Chicago metropolitan area. Am. J. Infect. Control. 2012, 40, 201–205. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yoo, S.; You, Y.; Kwan, K.C.; Jeong, T.O. Bacterial contamination conditions in ambulances and their equipment in South Korea. J. Korean Soc. Emerg. Med. 2012, 23, 1–7. [Google Scholar]
- Lesho, E.; Ake, J.; Huang, X.Z.; Cash, D.M.; Nikolich, M.; Barber, M.; Robens, K.; Garnett, E.; Lindler, L.; Scott, P. Amount of usage and involvement in explosions not associated with increased contamination of prehospital vehicles with multi-drug-resistant organisms. Prehospital Disaster Med. 2013, 28, 107–109. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Alrazeeni, D.; Al Sufi, M.S. Nosocomial infections in ambulances and effectiveness of ambulance fumigation techniques in Saudi Arabia. Phase I study. Saudi. Med. J. 2014, 35, 1354–1360. [Google Scholar] [PubMed] [PubMed Central]
- Luksamijarulkul, P.; Pipitsangjan, S. Microbial air quality and bacterial surface contamination in ambulances during patient services. Oman Med. J. 2015, 30, 104–110. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
- Wepler, M.; Stahl, W.; von Baum, H.; Wildermuth, S.; Dirks, B.; Georgieff, M.; Hafner, S. Prevalence of nosocomial pathogens in German ambulances: The SEKURE study. Emerg. Med. J. 2015, 32, 409–411. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Makiela, S.; Taylor-Robinson, A.W.; Weber, A.; Maguire, B.J. A preliminary assessment of contamination of emergency service helicopters with MRSA and multi-resistant Staphylococcus aureus. Emerg. Med. Open Access 2016, 6, 1–6. [Google Scholar] [CrossRef]
- Vikke, H.S.; Giebner, M. POSAiDA: Presence of Staphylococcus aureus/MRSA and Enterococcus/VRE in Danish ambulances. A cross-sectional study. BMC Res. Notes 2016, 9, 194. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
- Varona-Barquin, A.; Ballesteros-Peña, S.; Lorrio-Palomino, S.; Ezpeleta, G.; Zamanillo, V.; Eraso, E.; Quindós, G. Detection and characterization of surface microbial contamination in emergency ambulances. Am. J. Infect. Control. 2017, 45, 69–71. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Vikke, H.S.; Giebner, M.; Kolmos, H.J. Prehospital infection control and prevention in Denmark: A cross-sectional study on guideline adherence and microbial contamination of surfaces. Scand. J. Trauma Resusc. Emerg. Med. 2018, 26, 71. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
- El-Mokhtar, M.A.; Hetta, H.F. Ambulance vehicles as a source of multidrug-resistant infections: A multicenter study in Assiut City, Egypt. Infect. Drug Resist. 2018, 11, 587–594. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
- Gibson, C.V. Emergency medical services oxygen equipment: A fomite for transmission of MRSA? Emerg. Med. J. 2018, 36, 89–91. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Paravar, M.; Safavi, S.; Eghtesadi, R.; Mohamadzade, M.; Sehat, M.; Fazel, M.; Fakharian, E.; Makki, M.; Erami, M.; Taghipor, T.; et al. The prevalence of Staphylococcus aureus contamination in the ambulances and on-all emergency medical service personnel of Kashan city in Iran. J. Emerg. Pract. Trauma 2019, 6, 3–6. [Google Scholar] [CrossRef] [Scilit]
- Sharma, S.; Datta, P.; Gupta, V.; Vasesi, D.; Chander, J. Bacteriological Surveillance of Ambulance Vehicles from a Tertiary Care Hospital of North India. J. Lab. Physicians 2021, 13, 202–207. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
- Leszczyński, P.K.; Olędzka, A.; Wierzchowska, K.; Frankowska-Maciejewska, A.; Mitura, K.M.; Celinski, D. Occurrence and Phenotypic Characteristics of Methicillin-Resistant Staphylococcus aureus (MRSA) in Emergency Medical Service Ambulances as a Potential Threat to Medical Staff and Patients. J. Clin. Med. 2024, 13, 7160. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
- Ehling-Schulz, M.; Lereclus, D.; Koehler, T.M. The Bacillus cereus Group: Bacillus Species with Pathogenic Potential. Microbiol. Spectr. 2019, 7, 10–128. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
- Kao, C.C.; Chiang, C.K.; Huang, J.W. Micrococcus species-related peritonitis in patients receiving peritoneal dialysis. Int. Urol. Nephrol. 2012, 46, 261–264. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Huang, X.; Yu, L.; Sun, C.; Xiao, F.; Jia, N.; Chen, M.; Zhang, Y.; Fu, J.; Xu, Z.; Cui, X.; et al. Visual and fluorescent detection of Moraxella catarrhalis by multiple cross displacement amplification-based assay. Heliyon 2024, 10, e38805. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
- Daniel, W.W. (Ed.) Biostatistics: A Foundation for Analysis in the Health Sciences, 7th ed.; John Wiley & Sons: New York, NY, USA, 1999. [Google Scholar]
- Cheesbrough, M. (Ed.) Microbiological tests. In District Laboratory Practice in Tropical Countries; Cambridge University Press: New York, NY, USA, 2006; pp. 62–70. [Google Scholar]
- Clinical and Laboratory Standards Institute (CLSI). Performance Standards for Antimicrobial Susceptibility Testing, 35th ed.; CLSI Supplement M100; Clinical and Laboratory Standards Institute: Wayne, PA, USA, 2025. [Google Scholar]
- Dancer, S.J. Hospital cleaning in the 21st century. Eur. J. Clin. Microbiol. Infect. Dis. 2011, 30, 1473–1481. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mulvey, D.; Redding, P.; Robertson, C.; Woodall, C.; Kingsmore, P.; Bedwell, D.; Dancer, S.J. Finding a benchmark for monitoring hospital cleanliness. J. Hosp. Infect. 2011, 77, 25–30. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Saudi Ministry of Health (MOH; 2019). Emergency Medical Services (EMS) Infection Control Guidelines. Available online: https://jed-s3.bluvalt.com/psj1-ifn-s3-ifn01/files/03/Guidelines/Emergency-Medical-Services-EMS-Infection-Control-Guidelines-2019.pdf (accessed on 15 November 2025).
- Giovinazzo, R.; Caradonna, L.; Giaquinta, G.; Guerrera, E.; Mameli, M.; Mansi, A.; Marena, G.; Mastromartino, T.; Sarto, D.; Tomao, P. Benchmark Guidance Values for Microbiological Monitoring on Surfaces: A Literature Overview. Biomed. Prev. Issues 2017, 4, 174–180. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).