Abstract
With the growing demand for seismic resilience in urban building structures, the development of high-performance energy-dissipation components has become critical for enhancing structural safety and mitigating earthquake-induced damage. Traditional buckling restrained braces (BRBs) are typically designed to remain elastic under frequent earthquakes, limiting their ability to dissipate early seismic energy input. To address this limitation, a novel friction-damped double-stage yield buckling restrained brace (FD-DYBRB) is proposed by integrating friction dampers (FDs) with a conventional BRB. The mechanical performance of both the traditional BRB and the proposed FD-DYBRB was investigated through cyclic loading tests. Additionally, to evaluate the performance differences among various configurations, a cross-shaped double-stage yield BRB was also tested for comparison. The experimental results demonstrate that the proposed FD-DYBRB design is highly effective, exhibiting plump hysteretic curves and distinct double-stage yielding characteristics. Specifically, the FD-DYBRB possesses an initial stiffness ranging from 249.38 kN/mm to 250.31 kN/mm, which is comparable to traditional BRBs. Under small displacements, its equivalent damping ratio increases by approximately 7% for every 50 kN increase in friction force, achieving continuous early-stage energy dissipation. Furthermore, the proposed brace realizes full-process energy dissipation by maintaining stable average tensile and compressive capacities of 87.08 kN and 84.50 kN, respectively, even after the core plate fractures. Compared to the traditional BRB, the maximum dissipated energy of the FD-DYBRB increases by 23.55% to 54.75%, and its maximum equivalent damping ratio exceeds that of the cross-shaped DYBRB by 5%. These findings offer a reliable technical solution for improving the seismic performance of high-rise and long-span buildings, ultimately helping to mitigate structural damage and protect life and property during seismic events.
1. Introduction
Earthquakes are among the most devastating natural disasters in terms of human casualties. Their sudden and unpredictable nature causes enormous harm. There are three major seismic belts worldwide: the Circum-Pacific Seismic Belt, the Eurasian Seismic Belt, and the Ocean Ridge Seismic Belt [1,2]. With the acceleration of urbanization, the number of high-rise buildings, long-span public buildings, and prefabricated buildings has increased significantly. Such structures are characterized by complex configurations and uneven stiffness distribution, which make them prone to excessive lateral displacement, local damage, or even overall collapse under seismic action, posing higher requirements for structural seismic design [3,4,5,6]. Meanwhile, the seismic performance of existing buildings is generally insufficient to meet the current stringent seismic codes. How to improve the seismic energy dissipation capacity of various building structures and reduce earthquake-induced losses has become a core issue urgently needing to be addressed in the field of civil engineering. The design principle of conventional seismic-resistant structures prioritizes the plastic deformation of secondary structures, utilizing their inherent energy dissipation capacity to dissipate seismic energy [7,8]. However, this passive seismic approach has limitations, such as the inability to predict seismic effects and over-reliance on a single seismic system, which makes it difficult to meet the dual requirements of energy dissipation efficiency and damage control for high-rise, multi-story, and long-span buildings. Under strong earthquakes, it is prone to irreversible damage to the main structure, increasing the cost and difficulty of post-earthquake repair.
An emerging solution involves integrating dampers strategically within the structure to create a collaborative system that dissipates energy effectively [9,10]. This technology absorbs seismic energy through the deformation of dampers and allows for post-earthquake inspection and repair. It is not only suitable for the seismic design of new buildings but also applicable to the seismic retrofitting of existing buildings, demonstrating favorable economic viability and engineering applicability.
As highly efficient passive control devices, friction dampers (FDs) rely on friction-induced energy dissipation as their core principle. They convert seismic input energy through sliding friction at contact interfaces, thereby significantly reducing structural responses. Characterized by a small slip displacement, a large design displacement, structural simplicity, stable energy dissipation performance, and favorable economic benefits, FDs have been widely applied in engineering practices [11,12]. However, the energy dissipation capacity of FDs tends to degrade with the loss of preload. Furthermore, traditional FDs typically provide a constant friction force, which means their energy dissipation characteristics cannot be adjusted under varying seismic conditions. Consequently, it is difficult for them to meet the vibration mitigation requirements of structures across the entire range of seismic displacements. To enhance their performance, scholars worldwide have recently focused their research on multi-stage energy dissipation mechanisms. Existing approaches primarily involve several mechanisms. Reference [13] achieved graded energy dissipation by connecting friction units with different preloads in series through a proposed dual-damper series structure. Reference [14] realized nonlinear friction behavior by designing specific friction surface geometries, introducing concave–convex curved friction plates and a U-T slope friction device, respectively. Furthermore, Reference [15] combined friction units with other energy dissipation components, proposing a novel bending-friction-coupled damper by integrating a friction device with bending bars. Although these methods have made certain progress in enhancing the energy dissipation capacity of friction devices, they generally suffer from drawbacks such as structural complexity, high manufacturing costs, and inconvenient adjustability, which limit their widespread application in engineering practice.
BRBs serve as seismic damping devices, utilizing the plastic energy dissipation of a metal core plate. To prevent compression buckling of the core plate, restraining elements are installed around its perimeter, addressing the limitations of conventional steel braces. BRBs exhibit excellent energy dissipation capabilities during seismic events, making them widely utilized in building structures [16]. However, traditional buckling-restrained braces (BRBs) exhibit a notable limitation: they typically remain in an elastic state without yielding or dissipating energy under frequent earthquakes and only activate their energy dissipation mechanism under design-basis or rare earthquakes. To address the singular energy dissipation mode and limited cost-effectiveness of BRBs in practical applications, the concept of “dual-yield” has been proposed in recent years. Researchers worldwide have developed composite BRBs by integrating various types of dampers with conventional BRBs to achieve dual-yield energy dissipation.
Studies [17,18,19] indicate that conventional BRBs suffer from insufficient energy dissipation under rare earthquakes and wind loads, thereby proposing a hybrid solution termed the “Hybrid BRB”. Comparative tests on the internal core plates of conventional BRBs and Hybrid BRBs demonstrated that the latter exhibits superior seismic performance. Furthermore, integrating smart control technologies into bracing systems has emerged as a research hotspot. For instance, Reference [20] proposed a novel semi-active magnetorheological (MR) damper and systematically evaluated a new seismic protection system that combines this MR damper with BRBs. Alternatively, focusing on internal structural optimization, Reference [21] proposed a novel dual-yield assembled BRB with replaceable cores (DYP-ABRB) based on the concept of rapid post-earthquake repair, which realizes a dual-yield mechanism by configuring core plates of varying lengths. Nevertheless, devices such as MR dampers often suffer from high costs, complex configurations, and a reliance on external power supplies. Meanwhile, purely mechanical assembled dual-yield braces still exhibit limitations regarding the adjustment of initial stiffness and the flexibility of their energy dissipation mechanisms.
In response to the prevalent limitations of existing hybrid BRBs—namely, high costs, complex configurations, and the lack of flexibility in tuning yield mechanisms—this paper proposes a novel dual-yield buckling-restrained brace (DYBRB) that integrates a friction damper (FD) with a conventional buckling-restrained brace (BRB). Distinguished from traditional hybrid braces, the core innovation of this design lies in its sequential energy dissipation mechanism: the FD slips first to provide early and stable energy dissipation under minor to moderate earthquakes, while the axial yielding of the BRB serves as the primary energy dissipation mechanism under severe earthquakes. Consequently, this design achieves an ideal dual-yield behavior and establishes multiple seismic defense lines through a more economical and simplified modular mechanical configuration.
To systematically elucidate the mechanical behavior and practical efficacy of this novel component, low-cycle reversed cyclic loading tests were conducted. A comprehensive comparative study on the mechanical characteristics and energy dissipation performance between the DYBRB and the conventional BRB was performed to verify the reliability of its dual-yield features. Furthermore, to investigate the influence of internal structural configurations on mechanical performance, a DYBRB featuring a “cross-shaped” inner core was specifically designed and introduced as a control group in the experiments. The results demonstrate that the proposed DYBRB not only effectively overcomes the deficiency of conventional braces regarding insufficient energy dissipation under minor to moderate earthquakes, but its modular design and the post-earthquake replaceability of core components also offer a highly promising and resilient solution. This makes it particularly suitable for vibration-sensitive high-rise and large-span structures, as well as for the cost-effective seismic retrofitting of existing buildings.
2. Experimental Program
2.1. Specimen Composition and Working Mechanism
The proposed FD-DYBRB comprises a hybrid configuration of an FD and a BRB. As illustrated in Figure 1a, the FD is positioned at the end of the BRB, forming a tandem system with the external restraining sleeve. This tandem system is connected in parallel with the core plate of the BRB to ensure identical axial displacements, thus establishing a cohesive force transfer mechanism. The clamp plate is inserted into the designated slot of the outer sleeve, facilitating connection via welding. The BRB component primarily consists of the inner metal energy-dissipating core plate, with a concrete-filled steel tube encasing it to prevent global buckling under compression. An unbonded layer separates the two components, minimizing and delaying friction with the outer sleeve by providing a gap to accommodate the transverse expansion of the core plate caused by the Poisson effect during compression. The FD component encompasses the clamp plates, friction pads, stiffening ribs with slotted holes, baffle plates, high-strength bolts, disc springs, gaskets, and other associated elements. The exploded views of the FD-DYBRB structure and its terminus are depicted in Figure 1b and Figure 1c, respectively.
Figure 1.
Structural diagram of DYBRB.
During assembly, a predetermined torque is applied to the high-strength bolts of the FD-DYBRB. Under frequent earthquakes, the stiffening ribs with slotted holes undergo relative displacement against the friction plates affixed to the clamp plate, resulting in sliding friction under external forces. Meanwhile, the core plate simply undergoes elastic deformation and remains in an elastic state. Under severe or rare earthquakes, the built-in metal core plate yields and dissipates energy. Simultaneously, it collaborates with the FD, capitalizing on the latter’s significant design displacement to ensure joint seismic energy dissipation by both components. Throughout the operational phases of the FD-DYBRB, the axial deformation of the energy-dissipating core plate matches the displacement of the stiffening ribs with slotted holes. To meet the double-stage yield energy dissipation requirement, the initial slip displacement of the FD-DYBRB’s FD component is intentionally set smaller than the yield displacement of the metal core plate.
2.2. Specimen Design
Following the delineation of constructional forms in the preceding section, three new FD-DYBRB test specimens were designed and manufactured (designated as DYBRB-1, DYBRB-2, and DYBRB-3), alongside a traditional BRB (designated as T-BRB), and a “cross-shape” core plate DYBRB (designated as DYBRB-4) were utilized as control groups for testing. The inclusion of DYBRB-4 aims to address a specific comparative scientific question: whether and how the cross-sectional shape of the core plate (linear versus cross-shaped, both being common configurations in practical engineering) influences the overall mechanical performance of the DYBRB when combined with the FD. Among these, the T-BRB and DYBRB-1, DYBRB-2, and DYBRB-3 all featured a uniform linear shape metal energy-dissipating core plate (16 mm × 105 mm) and identical buckling restraint sleeves (150 mm × 150 mm × 8 mm). Furthermore, all specimens were coated with a 2 mm waterproofing membrane on the core plate surfaces, and C40 fine-grained concrete was filled between the metal energy-dissipating core plates and the buckling restraint sleeves. The sliding friction force of the FD at the terminations of DYBRB-1, DYBRB-2, and DYBRB-3 was set at 100 kN, 150 kN, and 200 kN, respectively. These target friction forces were achieved by applying specific preloads to M20 class 10.9 high-strength bolts using a calibrated torque wrench. To ensure a stable and reliable friction coefficient, the sliding surfaces of the friction panels were treated by wire brushing to achieve a uniform surface roughness. Furthermore, preliminary sliding tests were conducted prior to the formal loading to verify the actual friction forces. The measured friction forces exhibited an acceptable tolerance/uncertainty of approximately ±5%, primarily attributed to minor bolt relaxation and initial surface wear. To ensure a rigorous comparison, DYBRB-4 maintained the same second-stage yield force as DYBRB-1. Its internal cross-shaped metal energy-dissipating core plate comprises a web made of LY100 (8 mm × 40 mm) and a flange made of Q235 (16 mm × 120 mm). The assembly employed welding, with the Q355 reinforcement section integrated at the end. The sleeve dimensions were 150 mm × 150 mm × 6 mm, while the treatment of other components mirrored that of the T-BRB. Detailed component dimensions for each test specimen and the FD situated at the end of DYBRB-1 to DYBRB-3 are illustrated in Figure 2. Design parameters for each test specimen are outlined in Table 1. represents first-order yield displacement; represents first-order yield force; represents double-stage yield displacement; and represents double-stage yield force.
Figure 2.
Dimension of specimens.
Table 1.
Design parameters of specimens.
To ensure that the series system (comprising the friction damper and the external restraint sleeve) works in parallel with the internal energy-dissipating core plate, a specific spatial configuration was designed. At one end of the brace (the fixed end, opposite to the FD), the core plate adopts a locally enlarged section which is directly welded to the external restraint sleeve, creating a shared anchor point. At the other end (the sliding end, as shown in Figure 3a,c), the core plate and the sleeve remain independent, and the friction damper (FD) is installed between them. Under axial loading, the force splits at the fixed end: one portion is transmitted directly through the internal core plate, while the other portion travels through the outer sleeve to activate the FD at the sliding end. The processing and fabrication site plan of the test specimens is depicted in Figure 3.
Figure 3.
Specimen processing site.
The mechanical properties of the materials were determined according to relevant Chinese standards. The steel plates (LY100, Q235, and Q355) conform to the national standards, with nominal yield strengths of 100 MPa, 235 MPa, and 355 MPa, respectively. The high-strength bolts used in the friction damper conform to GB/T 3098.1. Additionally, the C40 concrete infill was used, which has a standard cube compressive strength of 40 MPa.
2.3. Specimen Installation
The experiment took place in a steel structure laboratory in Huqiu District, Suzhou, China, utilizing a PWS-1200 large-scale multifunctional structural test system manufactured by Jinan Dongce in Jinan, China, with a servo linear actuator serving as the loading device. The test system has an effective space length of 3500 mm, a width of 1500 mm, a maximum loading force of 1200 kN, and a loading displacement stroke of up to ±500 mm. Installation details of the testing apparatus and specimens are illustrated in Figure 4.
Figure 4.
Testing instruments and installation detail.
2.4. Loading Scheme
The test loading was divided into two stages: the pre-loading elasticity stage and the formal loading stage. In the pre-loading stage, force-controlled loading was applied up to 25% of the design capacity. In the formal loading stage, static low-cycle reciprocating displacement was applied at a loading speed of 0.1 mm/s, complying with the requirements outlined in GB 50011-2010 [22]. During the variable amplitude loading stage, the T-BRB specimens were loaded at amplitudes of 1/300, 1/200, 1/150, and 1/100 of the total specimen length (L), with three cycles for each amplitude. For the DYBRB specimens (DYBRB-1 to DYBRB-4), since they yield to first-order under small displacements, additional loading amplitudes and were introduced prior to the standard amplitudes to better understand their mechanical behavior. Following the variable amplitude stage, both groups underwent a fatigue loading stage to compare their mechanical behavior throughout the entire process. The loading amplitude was unified and reduced to 1/150 L for 30 reciprocating cycles. If the core plate did not fracture, the amplitude was increased to 1/100 L until the specimen’s load-bearing capacity decreased, at which point loading was stopped (for DYBRB specimens, this final amplitude was maintained for an additional 15 cycles if fracture did not occur earlier). The loading schemes of the specimens are illustrated in Figure 5.
Figure 5.
Loading schemes of specimens.
2.5. Measurement Arrangement
Displacement meters 1 and 2 measured the relative deformation at both ends of the specimen’s core plate, with their average value representing the axial deformation of the specimen. Displacement meter 3 measured the axial deformation of the outer constraint sleeve. The arrangement of these displacement meters is depicted in Figure 6.
Figure 6.
Location of displacement meters.
3. Experimental Phenomena
3.1. Experimental Phenomena of T-BRB
During the loading process, T-BRB specimens exhibited no bulging in the external restraint sleeve, indicating sufficient bending capacity. The core plate experienced noticeable compression and tensile deformation. The welds connecting the right core plate to the external restraint sleeve and the stiffening rib to the external restraint sleeve remained intact. However, during fatigue loading up to the 46th cycle, a splitting sound occurred, signaling a decrease in specimen bearing capacity. Subsequent examination revealed local buckling outer extending portion of the core plate, with a maximum deformation of 2.5 mm, as depicted in Figure 7. It should be noted that under large compressive deformations, the core plate undergoes higher-order buckling. The crests of these buckling waves compress the unbonded layer and eventually contact the inner wall of the sleeve, generating sliding friction. This friction contributes to a higher compressive capacity compared to the tensile capacity.
Figure 7.
T-BRB specimen test phenomena.
3.2. Experimental Phenomena of DYBRB
After installing the DYBRB-1 to DYBRB-3 specimens, the predetermined preloads were applied using a calibrated torque wrench in a diagonal sequence across the bolts to achieve the target friction forces, such as a torque of 300 N·m for specific configurations. Throughout the loading process, the stiffening ribs with slotted holes and the baffle plate with friction panels exhibited relative displacement, yet no evident local buckling was observed in the specimens. This suggests that the attached FD exerted a strong restraining effect on the outer extending portion of the core plate, surpassing the effect observed in the T-BRB specimen. During the fatigue loading stage, the preload was completely released, and then the preset torque was reapplied, with new disc springs replacing the old ones. Six disc springs were installed in parallel for each bolt to maintain a significant force on the bolts during operation.
Throughout the loading process, powder continued to drop to the ground. This phenomenon was caused by the continuous relative sliding and abrasive wear between the friction panels and the stiffening ribs under the high normal pressure exerted by the preloaded bolts during cyclic axial loading. The continuous generation of this wear debris directly reflects the force state of the FD and indicates that it was actively participating in energy dissipation. DYBRB-1, DYBRB-2, and DYBRB-3 underwent fatigue loading for 49, 47, and 46 cycles respectively, after which a loud splitting sound was heard, indicating core plate fracture and a subsequent decrease in load-bearing capacity. Following this, the FD system continued to provide load-bearing capacity to the specimens. After the completion of the test, the end of the DYBRB-1 specimen was sectioned, revealing no significant in-plane or out-of-plane deformation in the core plate outreach section. Clear friction marks were evident on the stiffening ribs with slotted holes, and the welds between the cover plate and the reserved groove of the outer sleeve remained intact with no fractures. The friction panels showed no signs of damage. These observations are depicted in Figure 8a. The experimental phenomena of DYBRB-2 and DYBRB-3 are depicted in Figure 8b,c. Bulging occurred on the external restraint sleeve; however, no local buckling was observed in the outer extending portion of the core plate. During the 22nd cycle of the fatigue loading process for DYBRB-4, a regular dull sound was heard during the compression stage when the bearing capacity declined. From the perspective of the damage evolution process, this sound served as an early indicator of internal structural degradation under high compressive stress. It was attributed to the pressure-induced fracture at the welded connection between the LY100 steel core plate and the reinforced Q355 steel section, causing misalignment between the two components and disrupting the stable internal load transmission path. Subsequently, during the 40th cycle of the tensile stage, a significant cracking sound was accompanied by the fracture of the core plate. This event marked the ultimate limit state of fatigue damage accumulation for the inner core, resulting in a sudden loss of its primary tensile resistance.
Figure 8.
DYBRB specimen test phenomena.
Furthermore, bulging was observed on both sides of the specimen’s external restraint sleeve at distances of 55 cm and 65 cm from the end plate. This deformation was directly linked to the complex internal force state: as the core plate yielded and buckled under severe compression, it exerted a significant lateral expansion force that exceeded the local out-of-plane restraint stiffness of the external sleeve. These combined failure modes led to the termination of loading. The experimental phenomena for DYBRB-4 are illustrated in Figure 8d. Compared to the linear-shaped core plates (T-BRB and DYBRB-1 to 3), the cross-shaped core plate of DYBRB-4 exhibits different buckling modes and contact areas with the sleeve under severe compression. Consequently, the extrusion force and the resulting sliding friction at the contact points vary, which may lead to differences in the degree of compression-tension asymmetry between the linear and cross-shaped configurations.
4. Test Result and Discussion
4.1. Hysteresis Curve
The hysteresis curve and skeleton curve of each specimen are illustrated in Figure 9. The hysteresis curve is further categorized into variable loading and fatigue loading hysteresis curves.
Figure 9.
Hysteresis curve and skeleton curve of specimens. (Different colors in the skeleton curves are used to distinguish various specimens).
The hysteresis curves of each specimen, as shown in Figure 9, exhibit full and stable behavior under cycle loads, without evident strength and stiffness degradation or pinching phenomena. Specifically, in Figure 9d,e,g,h,j,k, it is evident that specimens DYBRB-1 to DYBRB-3 demonstrate pronounced double-order yielding characteristics, forming complete hysteresis circles under small displacement loading amplitudes. These specimens maintain stable energy dissipation capacity even after a decrease in bearing capacity during fatigue loading. For instance, taking DYBRB-1 as an example, its bearing capacity diminished in the 49th tensile stage of the fatigue loading process, causing the core plate of the specimen to fracture. Mechanistically, while the additional friction enhances early-stage energy dissipation, it also imposes extra local axial restraints and shear forces on the core plate, which exacerbates local stress concentration and accelerates the initiation of fatigue cracks. Subsequently, under further loading, DYBRB-1 demonstrated that the energy-consuming core plate was not dissipating energy, while the FD and the tandem system formed by the restraining member operate independently to provide bearing capacity. During the compression loading process, the two broken parts of the core plate compressed against each other, causing a steep increase in the bearing capacity of DYBRB-1. The tandem system’s load-carrying capacity demonstrates greater stability, with the tensile and compressive load-carrying capacities averaging 87.08 kN and 84.50 kN, respectively. Results indicate that during fatigue loading, the load-carrying capacity of the FD component decreased significantly. This macroscopic degradation in load-carrying capacity is fundamentally attributed to the wear of the contact surfaces and the relaxation of the preload, which are caused by the continuous relative sliding between the friction panels and the core plate during prolonged fatigue cycles. However, the FD-DYBRB demonstrated stable energy dissipation capacity throughout the entire process.
It is crucial to clarify the engineering implications of the system’s post-fracture behavior. The observed residual bearing capacity and energy dissipation provided by the FD component act strictly as a fail-safe mechanism during a Maximum Considered Earthquake to prevent sudden structural collapse, rather than an acceptable state for continued service. Following a core plate fracture, the primary axial stiffness drops drastically, and the remaining strength relies solely on the degrading friction of the FD. Furthermore, the jamming of the broken core ends under compression creates a severe tension-compression asymmetry that introduces significant unbalanced forces and stability risks to the global frame. In practical post-earthquake assessments, such ultimate failure can be diagnosed through excessive residual inter-story drifts, pronounced sliding marks on the FD, or localized sleeve deformation, dictating that the entire FD-DYBRB unit must be completely replaced rather than repaired.
Furthermore, examination of Figure 9m,n reveals that under the small displacement loading regime of DYBRB-4, the LY100 core plate exhibited yielding before the Q235 core plate, accomplishing the objective of double-order yielding. However, the manifestation of double-order yielding in DYBRB-4 is not readily apparent. This can be attributed to the mechanical property of the LY100, leading to a theoretical calculated ratio of first-order stiffness to second-order stiffness of 1.34, with both stiffness values being closely matched. During reciprocating loading, the fracture of welded joints between the LY100 core plate and the Q235 core plate caused a slight reduction in tensile capacity, decreasing from 861.42 kN to 611.96 kN. Simultaneously, the compression stage experienced a more significant decrease, dropping from 985.02 kN to 501.62 kN.
Figure 9c,f,i,l illustrate that the T-BRB specimens exhibit distinct bilinear characteristics in their skeleton curves. In contrast, the FD-DYBRB specimens display trilinear curves, indicating clear double-order yielding during loading. Following partial slippage of the FD, the phase difference in force during loading aligns closely with the predetermined friction force. This phenomenon occurs because the magnitude of the preset friction directly determines the critical force for the FD to initiate sliding; a higher friction force requires a greater axial load to overcome static friction, thereby delaying the initial displacement of the second-stage yielding. Upon overcoming static friction between the stiffening rib and the friction panel, the stiffnesses of DYBRB-1 to DYBRB-3 and T-BRB are 250.28 kN/mm, 249.38 kN/mm, 250.31 kN/mm, and 260.89 kN/mm, respectively. The stiffness differences are 4.07%, 4.41%, and 4.06%, respectively, showing negligible variation.
Figure 9o demonstrates that under large-displacement loading, the compressive load capacity of DYBRB-4 exceeds its tensile load capacity. As previously noted, the ratio of first-order stiffness to second-order stiffness in DYBRB-4 is 1.37, which fails to distinctly illustrate double-order yielding in the skeleton curve. Moreover, with increasing loading amplitude, the cyclic hardening characteristics of LY100 material result in a higher bearing capacity for DYBRB-4 compared to DYBRB-1 to DYBRB-3 specimens, after the yielding of both LY100 and Q235 core plates in DYBRB-4.
4.2. Compression Strength Adjustment Factor
The core plate of the BRB exerts a mutual contact force on the external restraint sleeve when subjected to an external force of a certain magnitude. Due to the substantial bending stiffness of the external restraint sleeve, it effectively restricts the bending deformation of the core plate, causing a transition in the flexural mode from low-order to high-order. Additionally, a relative slip occurs between the core plate and the external restraint sleeve, generating friction. Consequently, the compression bearing capacity of the BRB surpasses its tension bearing capacity, leading to an asymmetric load characteristic evident in the hysteresis curve. This asymmetry can be assessed through parameters such as the compression strength adjustment factor and residual deformation of the BRB. In this study, we utilize the compression strength adjustment factor index β for evaluation. The compression strength adjustment factor, expressed as β = Fcmax/Ftmax (where Fcmax and Ftmax denote the maximum compressive and tensile bearing capacities of the current cycle, respectively, both taken as absolute values), is presented in Table 2 for each specimen.
Table 2.
Compression strength adjustment factor.
Examination of the table reveals that the maximum compression strength adjustment factor among the specimens is 1.134, aligning with the stipulation in ANSI/AISC 341-10 [23] that the coefficient should not exceed 1.3. Notably, at a large displacement of L/100, the β values for DYBRB-1, DYBRB-2, and DYBRB-3 are 1.113, 1.111, and 1.107, respectively, which are slightly lower than that of the conventional T-BRB (1.121). This highlights a unique stabilization mechanism introduced by the friction damper (FD). In ordinary BRBs, the Poisson effect and high-order buckling under large compressive displacements cause a sharp increase in friction between the core plate and the sleeve, thereby exacerbating asymmetry. However, in the FD-DYBRB specimens, the total bearing capacity is the superposition of the core plate’s capacity and the FD’s friction. Because the friction provided by the FD is symmetric and essentially constant in both tension and compression, adding this constant value to both the tensile and compressive capacities mathematically drives their ratio closer to 1. This demonstrates that the FD not only facilitates double-order yielding but also effectively mitigates the deterioration of compressive strength asymmetry under large displacements. Furthermore, the highest β value of 1.134 observed in DYBRB-4 is fundamentally linked to its material properties. Since DYBRB-4 utilizes a dual-material configuration of LY100 and Q235, the significant cyclic hardening characteristics of the LY100 material, combined with its more pronounced lateral expansion (Poisson effect) under compression, lead to a larger increase in compressive friction. Despite this slight increase, all specimens exhibit a commendable symmetry in both tensile and compressive force directions, confirming that the construction of the FD-DYBRB is rational.
4.3. Stiffness Degradation Curve
A phenomenon of stiffness degradation in the member occurs under the reciprocating action of external loads, with the secant stiffness and stiffness degradation coefficient serving as evaluation indices. These indices are calculated using Equations (1) and (2), respectively. A comparison of the secant stiffness and stiffness degradation coefficient for each specimen is presented in Figure 10a,b. The peak load at the cycle of the level of loading is denoted as ; displacement corresponding to peak load is denoted as the initial stiffness of the specimen is denoted as .
From Figure 10a,b, it is evident that the stiffness of each specimen underwent significant variation at the beginning of the loading process. Rather than merely indicating a faster stiffness degradation rate compared to the conventional T-BRB, this rapid initial degradation signifies the anticipated activation of the double-yield mechanism. In terms of engineering significance, during the initial loading phase (corresponding to minor earthquakes or wind loads), the FD-DYBRB maintains a high initial stiffness to provide essential lateral resistance. As displacement increases (corresponding to moderate earthquakes), the sliding of the FD or the early yielding of the LY100 material causes a rapid reduction in stiffness. This indicates that the first-stage energy dissipation mechanism has been activated to absorb seismic energy and protect the main structure. The subsequently stabilized residual stiffness represents the second line of defense provided by the yielding of the main load-bearing core plate. Furthermore, the mechanical nature of this stiffness degradation differs between the two FD-DYBRB configurations. For the friction-type specimens (DYBRB-1 to DYBRB-3), the degradation is induced by the transition from static to kinetic friction. Once the maximum static friction is overcome, the tangential stiffness of the FD instantly drops to zero (providing only a constant friction force); thus, their degradation curves exhibit a distinct “steep drop” feature initially. Conversely, for the material-type specimen (DYBRB-4), the degradation is governed by the elastoplastic evolution of the low-yield-point steel (LY100). Unlike the friction type, the yielding of LY100 is a process of internal dislocation movement accompanied by strain hardening, which results in a relatively smoother and more continuous stiffness degradation process.
4.4. Energy Dissipation
The energy dissipation capacity of the specimen is assessed through the envelope area of the load–displacement curve, typically determined using the energy dissipation coefficient E or the equivalent damping ratio . In the case of a center-symmetric hysteresis curve, the equivalent damping ratio can be defined by Equation (3). denotes the energy dissipated by the hysteresis curve at the level, equal to the area enclosed by the hysteresis curve at that level; represents the elastic strain energy, calculated based on the maximum force and maximum loading amplitude of the current cycle Additionally, E represents the total dissipated energy of the specimen at each loading amplitude, expressed in kN·mm, and denotes the energy dissipation coefficient of the component.
The energy dissipation evaluation indexes of the two types of supports, T-BRB and DYBRB, are shown in Table 3, and the relationship curves between the dissipated energy, equivalent damping ratio and the axial displacement of the specimen are shown in Figure 10c,d.
Table 3.
Evaluation indexes of energy consumption of specimens.
Figure 10.
Comparison of mechanical performance indexes between T-BRB and DYBRBs.
From Table 3 and Figure 10c, it is evident that the total energy dissipation of each specimen continues to increase with displacement, indicating stability in energy dissipation across the four specimen groups during the loading process. Highlighting the advantage of “early activation” at small displacement amplitudes (corresponding to frequent earthquakes or wind loads), the traditional T-BRB remains in an elastic state and fails to provide damping. In contrast, the FD-DYBRB successfully activates the first-stage energy dissipation mechanism (frictional sliding for DYBRB-1 to 3, and early yielding of LY100 for DYBRB-4). This demonstrates that the FD-DYBRB can intervene in the structural energy dissipation much earlier than the traditional BRB, which perfectly reflects the core intention of the “double-stage” design. With increased friction, energy dissipation in these specimens also rises. At maximum loading displacement, each specimen reached its maximum dissipated energy: 95,577 kN·mm, 118,084 kN·mm, 130,618 kN·mm, 147,904 kN·mm, and 137,510 kN·mm, respectively. Compared to T-BRB specimens, the maximum dissipated energy of DYBRB-1 to DYBRB-3 specimens increased by 23.55%, 36.66%, and 54.75%, respectively.
Table 3 and Figure 10d reveal that when the loading amplitude is reached, the equivalent damping ratio of T-BRB is zero, and the core plate remains elastic with minimal participation in energy dissipation. In contrast, the energy dissipation coefficients of DYBRB-1 to DYBRB-3 specimens at this stage were 0.917, 0.995, and 1.062, respectively, primarily reflecting the frictional energy dissipation characteristics of the FD-DYBRB specimen’s FD component. Based on the same buckling restrained brace section, the specimen’s equivalent viscous damping coefficient increased by approximately 7% on average for every 50 kN increase in the friction force under small displacement loading. At the same loading amplitude, the LY100 core plate of the DYBRB-4 enters yield and begins to dissipate energy, with the energy dissipation coefficient reaching 0.574. This suggests that the FD-BRB (DYBRB 1–3) exhibits superior energy dissipation capability compared to the “cross-shape” core plate double-order yielding buckling restrained brace (DYBRB-4) under small displacement loading. Moreover, the friction-based mechanism in FD-BRBs avoids the low-cycle fatigue degradation typically associated with the yielding of LYP steel (as seen in DYBRB-4) under frequent small-displacement cycles, thereby ensuring more durable long-term performance.
As the displacement increases (corresponding to major earthquakes), the yielding of the main core plate (Q235) marks the full activation of the second-stage energy dissipation mechanism. When the core plates of DYBRB-1 to DYBRB-3 specimens yielded, the energy dissipation coefficient increased significantly due to the collaborative action of the FD and the energy-dissipating core plate in dissipating energy. Similarly, when the Q235 core plate of the DYBRB-4 specimen yielded, its energy dissipation coefficient also increased notably, attributed to the collaborative action of the energy-dissipating core plate made of two different steel materials in dissipating energy. This synergistic working mechanism achieves massive energy dissipation under severe earthquakes. Upon attaching the FD to the end of the T-BRB, the specimens’ equivalent damping ratio increased by 10.61% for a friction force-to-load bearing capacity of core plate ratio of 0.2 (DYBRB-1), by 13.21% for a ratio of 0.3 (DYBRB-2), and by 17.62% for a ratio of 0.4 (DYBRB-3).
The maximum energy dissipation coefficient of DYBRB-1 exceeds that of DYBRB-4 by approximately 5%, even though DYBRB-4 exhibits a very high total absolute energy dissipation E. This apparent discrepancy can be explained by the mechanical definitions of these two metrics. As defined in Equation (3), the equivalent damping ratio represents the energy dissipation efficiency or the “plumpness” of the hysteresis loop, which is inversely proportional to the maximum restoring force . For DYBRB-4, the dual-steel core plates (LY100 and Q235) both undergo significant cyclic strain hardening at large displacements. This collaborative hardening leads to a pronounced increase in the maximum load-carrying capacity Fmax which substantially enlarges the denominator (elastic strain energy, ) in Equation (3). Consequently, while the absolute area under the curve is large, the hysteresis loop itself becomes more diagonal, lowering the . In contrast, the first-stage energy dissipation in DYBRB-1 to 3 relies on friction, which provides a constant resistance without strain hardening. This characteristic keeps the overall relatively lower and results in fuller and more rectangular hysteresis loops, thereby yielding a higher equivalent damping ratio. Therefore, while DYBRB-4 dissipates massive absolute energy, the FD-BRBs (DYBRB-1 to 3) exhibit superior energy dissipation efficiency.
5. Conclusions
An experimental study was conducted on T-BRB, FD-DYBRB (DYBRB 1–3), and DYBRB with “cross-shape” core plates (DYBRB-4) to evaluate and compare their seismic performance. The primary conclusions drawn from the study are as follows:
(1) The proposed FD-DYBRB successfully achieves full-process energy dissipation, which is the most crucial finding of this study. Experimental results demonstrate that even after the energy-dissipating core plates fracture under large deformations, such as at the 49th tensile stage of fatigue loading for DYBRB-1, the friction damper (FD) continues to operate stably and maintain energy dissipation. It provides stable average tensile and compressive capacities of 87.08 kN and 84.50 kN, respectively. In contrast, the DYBRB-4 specimen completely loses its ability to function after the rupture of its core plate.
(2) The double-order yielding mechanism of the FD-DYBRB was experimentally validated. Rather than just a design concept, the tests confirmed that the parallel connection allows the FD to dissipate energy via sliding friction during frequent earthquakes, achieving equivalent damping ratios ranging from 0.917 to 1.062 at small displacement amplitudes, whereas the traditional T-BRB provides zero damping. Meanwhile, the core plate yields to provide secondary energy dissipation under severe earthquakes.
(3) The FD-DYBRB specimens (DYBRB 1–3) exhibit higher initial stiffness and smaller first-order yielding displacements compared to DYBRB-4. This characteristic facilitates an earlier activation of the first-order yielding operational phase.
(4) The FD-DYBRB specimens exhibited stable hysteretic behavior and superior energy dissipation. Compared to the T-BRB, their maximum dissipated energy increased by 23.55%, compared to 54.75%, and the energy dissipation coefficient also showed significant improvement. Furthermore, the equivalent damping ratio increased by approximately 7% for every 50 kN increase in friction force under small displacements, and its maximum value exceeded that of the cross-shaped DYBRB-4 by 5%.
(5) Compared to the traditional double-order yielding braces that rely on low-yield-point (LYP) steel or complex “cross-shape” core plates (such as DYBRB-4), the proposed FD-DYBRB features a simpler structure, more convenient manufacturing process, and lower fabrication cost. This makes it a highly practical, economical, and reliable solution for structural seismic design.
Author Contributions
Conceptualization, Y.Z. and R.C.; methodology, Y.Z.; software, R.C.; validation, Y.Z.; formal analysis, Y.Z.; writing—original draft preparation, Y.Z.; writing—review and editing, W.S.; supervision, W.S.; funding acquisition, W.S. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the National Natural Science Foundation of China, grant number 51578114.
Data Availability Statement
The original contributions presented in the study are included in the article; further inquiries can be directed to the corresponding author.
Conflicts of Interest
The research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
References
- Zhu, L.; Feng, W.; Qian, G. Overview of worldwide earthquake disasters in 2022. Prog. Earthq. Sci. 2023, 53, 351–359. [Google Scholar] [CrossRef]
- Hussain, E.; Kalaycıoğlu, S.; Milliner, C.W.D.; Çakir, Z. Preconditioning the 2023 Kahramanmaraş (Türkiye) earthquake disaster. Nat. Rev. Earth Environ. 2023, 4, 287–289. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xiao, Z.H.; Huang, S.; Li, S.; Li, M.H.; Hu, Y. Low-damage seismic design approach for a long-span cable-stayed bridge in a high seismic hazard zone: A case study of the new Panama Canal Bridge. Buildings 2026, 16, 428. [Google Scholar] [CrossRef] [Scilit]
- Hsiao, F.P.; Lin, C.C.; Weng, P.W.; Haryanto, Y.; Llano, S.P.; Hu, H.T.; Nugroho, L.; Calad, A.S.; Hidayat, B.A. Seismic performance of a hybrid structural steel–reinforced concrete coupled wall building: Preliminary response estimates from an NCREE-QuakeCoRE joint study. Buildings 2026, 16, 246. [Google Scholar] [CrossRef] [Scilit]
- Almajhali, K.Y.M.; He, M.; Alhaddad, W.; Halabi, Y. Evolutionary Strategy for Performance-Based Seismic Design of High-Rise Structures: Novel Methodologie and Efficiency Analysis. Comput. Exp. Simul. Eng. 2025, 175, 763–777. [Google Scholar] [CrossRef] [Scilit]
- Xue, H.J.; Zhao, Z.; Li, P.; Shu, W.; Guan, Y.; He, D.; Wei, D.; Song, J. Application of amplified damped outrigger in seismic design of high-rise buildings. Struct. Des. Tall Spec. Build. 2024, 24, e2077. [Google Scholar] [CrossRef] [Scilit]
- Hossain, M.R.; Ashraf, M.; Albermani, F. Numerical modelling of yielding shear panel device for passive energy dissipation. Thin-Walled Struct. 2011, 49, 1032–1044. [Google Scholar] [CrossRef] [Scilit]
- Symans, M.D.; Charney, F.A.; Whittaker, A.S.; Constantinou, M.C.; Kircher, C.A.; Johnson, M.W.; McNamara, R.J. Energy dissipation systems for seismic applications: Current practice and recent developments. J. Struct. Eng. 2008, 134, 3–21. [Google Scholar] [CrossRef] [Scilit]
- De Domenico, D.; Ricciardi, G.; Takewaki, I. Design strategies of viscous dampers for seismic protection of building structures: A review. Soil Dyn. Earthq. Eng. 2019, 118, 144–165. [Google Scholar] [CrossRef] [Scilit]
- Gunay, H.; Torumbacı, N. Architectural Design of New Buildings with Seismic Base Isolation and Energy Damping Systems. J. Archit. Eng. 2024, 30, 03124002. [Google Scholar] [CrossRef] [Scilit]
- Jaisee, S.; Yue, F.; Ooi, Y.H. A state-of-the-art review on passive friction dampers and their applications. Eng. Struct. 2021, 235, 112022. [Google Scholar] [CrossRef] [Scilit]
- Pasquin, C.; Leboeuf, N.; Pall, R.T.; Pall, A. Friction dampers for seismic rehabilitation of Eaton’s building. In Proceedings of the Montreal 13th World Conference on Earthquake Engineering, Vancouver, BC, Canada, 1–6 August 2004; pp. 1–2. Available online: https://www.iitk.ac.in/nicee/wcee/article/13_1949.pdf (accessed on 4 March 2026).
- Yang, Y.; Xue, J.Y.; Liu, R. Experimental and numerical study on hysteresis behaviour of a novel dual-stage friction damper. Structures 2024, 70, 107911. [Google Scholar] [CrossRef] [Scilit]
- Qiu, C.X.; Bai, M.Y.; Liu, J.W.; Liu, H. Tests of friction dampers with enhanced recentering capability. Eng. Struct. 2025, 326, 119522. [Google Scholar] [CrossRef] [Scilit]
- Lu, Y.J.; Lv, Q.F.; Sun, T.F.; Liu, Y.; Tang, H.Y. Experimental and numerical studies on hysteretic behavior of a novel bending-friction coupled damper. Thin-Walled Struct. 2023, 183, 110385. [Google Scholar] [CrossRef] [Scilit]
- Chen, L.H.; Ma, G. Structural resilience and retrofit benefit evaluation method: Case studies on RC frames retrofitted with BRB. Earthq. Eng. Eng. Dyn. 2021, 41, 176–185. [Google Scholar] [CrossRef]
- Kim, D.H. Experimental Study on the Seismic Performance of Hybrid Buckling-Restrained Braces. J. Korean Soc. Hazard Mitig. 2013, 13, 23–29. [Google Scholar] [CrossRef] [Scilit]
- Kim, D.H.; Ju, Y.K.; Kim, M.H.; Kim, S.D. Wind-induced vibration control of tall buildings using hybrid buckling-restrained braces. Struct. Des. Tall Spec. Build. 2014, 23, 549–562. [Google Scholar] [CrossRef] [Scilit]
- Kim, D.H.; Kim, Y.S. Analytical Estimation on the Seismic Performance of Hybrid Buckling-Restrained Braces. J. Korean Assoc. Spat. Struct. 2014, 14, 57–65. [Google Scholar] [CrossRef] [Scilit]
- Vulcu, C.; Dubină, D.; Popa, N.; Vekas, L.; Ghiţă, G.; Sireteanu, T.; Borbath, I.; Oprescu, R. 11.13: Hybrid seismic protection system: Buckling restrained brace of nano-micro composite magneto rheological damper. Ce/papers 2017, 1, 2936–2945. [Google Scholar] [CrossRef] [Scilit]
- Zhang, A.; Wang, H.W.; Jiang, Z.Q.; Guo, K.; Niu, Z.Y. Numerical simulation analysis of double yield points assembled buckling-restrained brace with replaceable inner core. Structures 2021, 35, 1278–1294. [Google Scholar] [CrossRef] [Scilit]
- GB 50011-2010; Code for Seismic Design of Buildings. The Professional Standard Compilation Group of the People’s Republic of China: Beijing, China, 2010.
- ANSI/AISC 341-10; Seismic Provisions for Structural Steel Buildings. American National Standards Institute (ANSI): Washington, DC, USA; American Institute of Steel Construction (AISC): Chicago, IL, USA, 2010.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.