Abstract
To fill hydrogen fuel cell vehicles quickly and safely, the SAE J2601 protocol has published the MC method, which includes control of the filling speed and pressure target. The filling speed depends on the final filling time, the formula for which is obtained by fitting simulated data. The pressure target depends on the final hydrogen temperature, whose analytical solution is derived from a thermodynamic tank model. This article derives new analytical solutions of the final filling time and hydrogen temperature based on an established lumped-parameter model of the storage tank. Based on the original MC method’s control logic, a new filling method that directly uses the analytical solutions of the final filling time and hydrogen temperature was proposed. The simulation results of the new filling method and the validated model (zone-dimensional gas and a one-dimensional tank wall, 0D1D) are compared. Under the ambient temperature conditions of the 0–20 °C and precooling temperature conditions of −20–0 °C set in this article, results show that the new filling method achieves maximum errors of 4.3 °C in its final hydrogen temperature and 0.9% in a state of charge (SOC) compared to the 0D1D model. Parameter sensitivity analysis reveals that initial pressure has the most significant impact on computational accuracy, followed by ambient and precooling temperatures. Future work may further improve prediction accuracy by incorporating correction factors for initial pressure and ambient temperature. Moreover, since the analytical solution of the final hydrogen temperature inherently includes the precooling temperature parameter, the new filling method can automatically adapt to precooling temperature variations.
1. Introduction
Hydrogen fuel cell vehicles have emerged as a key development direction for new energy vehicles, owing to their advantages such as high efficiency and zero emissions. Achieving rapid and safe hydrogen filling is a critical technological requirement for enabling their commercial adoption [1]. The Society of Automotive Engineers (SAE) has issued a lookup table and MC methods for filling hydrogen vehicles quickly and safely. These methods are divided into communication and non-communication filling types. Communication type controls the filling process based on the tank’s temperature and pressure, measured by sensors, while the non-communication type is based on calculated temperature and pressure. This article focuses on the non-communication filling type [2].
For the non-communication lookup table method, the SAE relies on multiple tables generated in advance through simulations. The tables contain the pressure ramp rate (PRR), which controls the filling speed, and the pressure target, which controls the filling stop. The first step is to choose the table according to the nominal work pressure (NWP) of the vehicle tank (H70 means NWP is 70 MPa) and the precooling temperature category of the hydrogen refueling station (HRS) (T40 means the precooling temperature range of the HRS is −40 to −33 °C). The second step is to determine the PRR based on the ambient temperature. The third step is to determine the pressure target based on the initial tank pressure [2]. The PRR and pressure target in the table are determined through simulations under many extreme working conditions and verified by experiments [3,4].
The non-communication MC method, like the lookup table method, also includes the PRR to control the filling speed and the pressure target to control the filling stop, but the PRR and pressure target are not fixed. The PRR is calculated based on the final filling time. The final filling time is calculated based on the mass average temperature (MAT) of the delivered hydrogen. The formula for calculating the final filling time and its coefficients is determined by fitting a large volume of simulated data obtained under various extreme operating conditions. The MAT of the hydrogen is calculated based on the dispenser-measured temperature, pressure and mass flow rate of the delivered hydrogen. The pressure target is calculated from the final hydrogen temperature combined with the state-of-charge (SOC) target. The SAE-derived formula for the final hydrogen temperature is based on a simple physical model [5,6].
As mentioned above, both the lookup table and MC methods require, in advance, determining the relevant tables, formulas and coefficients. For example, in developing the lookup table method, parameters such as vehicle tank capacity class, dispenser nozzle type, station precooling temperature category, and delivery pressure category are used. Based on these, SAE employs simulations under extreme working conditions to predetermine 54 individual tables [2]. In developing the MC method, the formula and coefficients for the final filling time are derived as a polynomial fit to extensive data, obtained by simulation under various extreme conditions. SAE has established specific tables for these coefficients to facilitate queries during actual use. The determination of these tables, formulas, and coefficients represents a rigorous and systematic development effort [2]. Extending research to simplify the filling method is a natural and important technical direction to enhance overall operational efficiency.
A review of the literature indicates that several research teams have already investigated hydrogen filling methods. For instance, Chae et al. [7] proposed a hydrogen communication filling method based on real-time response, which optimizes filling time, precooling requirements, and energy consumption. Using the H2SCOPE model, Reddi et al. [8] compared the lookup table method and the MC method in terms of SOC and filling time. Furthermore, Chochlidakis et al. [9] evaluated the filling time, SOC and total energy consumption of the two methods under different operating conditions. Lv et al. [10] constructed a three-dimensional computational fluid dynamics model to analyze the effect of different hydrogen filling methods on the temperature distribution within a 210 L Type IV hydrogen storage tank. The study found that the SAE J2601 protocol [2] is also applicable to the filling process of heavy-duty vehicles. Handa et al. [11] proposed a novel filling method, the cTPR method, specifically for heavy-duty vehicles, with simulation results indicating that it can reduce filling time by 49 s while effectively lowering the final hydrogen temperature. Additionally, Martorelli et al. [12] conducted a systematic analysis of the hydrogen filling process for heavy-duty vehicles, investigating the effect of the inner diameter-to-length ratio of the hydrogen storage tank on filling performance, and comparing the differences in results obtained between the new method and the SAE protocol in practical applications. Table 1 presents different hydrogen filling methods, their characteristics, advantages, and disadvantages.
Table 1.
Different hydrogen filling methods, their characteristics, advantages and disadvantages.
This article derives the analytical solutions of the final filling time and hydrogen temperature to control the filling process and then proposes a new filling method based directly on analytical solutions. The simulation results for the new filling method are compared with those of the validated tank model. The comparison results show only a small discrepancy between the new filling method and the 0D1D model, demonstrating the effectiveness of the new method.
2. MC Filling Method
Figure 1 shows the filling control logic for the non-communication MC method, including control of the filling speed and pressure target [2].
Figure 1.
Filling control process of non-communication MC method.
According to the MC method, if we only consider the case where the precooling temperature is constant, the PRR controlling the filling speed can be expressed as
where and are the target and initial hydrogen pressure in the storage tank, and is the final filling time. Based on simulations under many extreme working conditions, SAE determined the formula for calculating the final filling time [2], as shown below:
where a, b, c and d are determined by SAE in advance through many extreme working condition simulations. MAT is the mass average temperature. The pressure target to control the filling stop can be expressed as
where is the SOC target. SAE derived and obtained the analytical solution of the final hydrogen temperature based on a simple physical model, which can be expressed as [2]
where is the final hydrogen mass, is the initial hydrogen temperature, and is the final hydrogen temperature, assuming adiabatic conditions. MC is a parameter and can be expressed as
where is the initial hydrogen internal energy. is the final hydrogen internal energy, assuming adiabatic conditions. AC, BC, GC, KC and JC are coefficients determined in advance [2]. They are empirical coefficients from the SAE J2601 protocol, obtained by fitting extensive data. They do not have direct physical meanings but collectively represent complex effects such as heat transfer between hydrogen and the tank wall, heat losses to the environment, and real-gas behavior at high pressures.
As shown in Figure 1, the MC method first calculates the MAT, then determines the final filling time using Equation (2), calculates the parameter MC via Equation (5), computes the final hydrogen temperature using Equation (4), and finally derives the target pressure from Equation (3). Refueling stops when the dispenser outlet pressure reaches the target pressure. Simultaneously, the PRR is calculated based on the target pressure and final filling time to control the refueling speed. Since Equation (2) is derived by fitting extensive simulation data, with its coefficients (a, b, c, and d) being functions of ambient temperature, tank volume, and initial pressure, SAE has established specific tables for these coefficients to facilitate queries during actual use. The need to consult these tables in practice may be inconvenient. This article proposes to replace Equations (2) and (4) of the MC method with new analytical solutions.
3. Filling Models of Dual-Zone Dual-Temperature (0D0D) and Zero-Dimensional Gas and One-Dimensional Tank Wall (0D1D)
We established a hydrogen storage tank model in which the hydrogen region is treated as a zero-dimensional lumped-parameter zone, as shown in Figure 2a. If we treat the wall region as a zero-dimensional lumped-parameter zone, as shown in Figure 2b, the resulting hydrogen storage tank model becomes a dual-zone dual-temperature lumped-parameter model (0D0D). This model will be used to derive the analytical solution of the final hydrogen temperature and filling time. In the dual-zone dual-temperature model, the wall temperature is assumed to be uniform, which is inconsistent with reality and may lead to errors. Therefore, we further consider the wall region as a one-dimensional lumped-parameter zone, as shown in Figure 2c. This model can be referred to as a zero-dimensional gas and one-dimensional tank wall model (0D1D), which will be used to verify the proposed new filling method.
Figure 2.
Model diagrams for zero-dimension hydrogen zone (a), zero-dimension wall zone (b) and one-dimension wall zone (c).
3.1. Dual-Zone Dual-Temperature Model (0D0D)
3.1.1. Governing Equations for the Hydrogen Zone
The mass and energy conservation equations for the hydrogen zone during filling can be expressed as [13]
where is the mass flow rate of hydrogen, is the specific internal energy of hydrogen, and is the specific enthalpy of hydrogen.
3.1.2. Governing Equations for the 0D Wall Zone
For the dual-zone dual-temperature model, the energy conservation of the tank wall during filling can be expressed as [13]
where , and are the temperatures of the hydrogen, tank wall and air; and are the mass and specific heat capacity of the tank wall; and are the inner and outer areas of the tank; and and are the heat transfer coefficients inside and outside the tank.
3.1.3. Analytical Solution of the Final Hydrogen Temperature
To solve Equations (7)–(9), that is, considering hydrogen and the tank wall as a whole, its energy conservation during the filling process can be expressed as
If certain assumptions are not made, deriving an analytical solution will be very difficult. Therefore, making certain assumptions may be a compromise. The MC method assumes that the temperature of the hydrogen and the wall are equal, , and the outer wall is adiabatic. This article also makes this assumption, so and Equation (10) can be expressed as
According to the Leibniz formula, . Due to , Equation (11) can be further expressed as
where is the precooling temperature, and and are the constant-volume and constant-pressure specific heat capacities of hydrogen.
Divide both sides of Equation (12) by at the same time, substitute = and define as the ratio of specific heat capacity, ; then Equation (12) can be expressed as
Solving Equation (13), we can get . Then substituting , we can further get . So, the final hydrogen temperature can be expressed as
where and are the initial hydrogen temperature and mass; is the final hydrogen mass; , where V is the volume of the tank and is known; and is the density corresponding to the target state of charge () set at the beginning of filling, with . Therefore, once is specified at the initial moment of filling, the final hydrogen mass can be determined, and the final hydrogen temperature can then be solved from Equation (14).
3.2. Zero-Dimensional Gas and One-Dimensional Tank Wall Model (0D1D)
To evaluate the new filling method more accurately, this section introduces a 0D1D model that accounts for detailed and realistic heat transfer through the tank wall. Its accuracy is superior to that of the dual-zone dual-temperature model presented in Section 3.1. The reliability of this 0D1D model is first validated against experimental data; it is then used as a benchmark to assess the new filling method. Due to this stepwise validation approach, additional uncertainty is introduced at each stage. A detailed analysis of the associated uncertainties will be provided in Section 4.4.
3.2.1. Governing Equations for the 1D Wall Zone
For the 0D1D model, the mass and energy conservation equations for the hydrogen zone are consistent with those of the dual-zone dual-temperature model, but the temperature of the tank wall cannot be treated as the lumped temperature Tw at this time. The heat transfer equation for a one-dimensional tank wall can be expressed as [14]
where , are the thermal conductivity, density and specific heat capacity of the tank wall. Boundary conditions of the inner and outer surfaces of the wall can be expressed as [14]
The hydrogen storage tank is assumed to be horizontally mounted under the vehicle chassis. Considering the potential presence of light outdoor breezes in real-world refueling environments, the forced convection heat transfer coefficient based on a cylinder cross-flow model is adopted. The heat transfer coefficient inside and outside the tank can be expressed as [15]
where and are the Reynolds numbers at the injector and inside the storage tank, respectively; and are the thermal conductivities of hydrogen and air, respectively; is the Prandtl number of air; and , and are the diameters of the injector, the inside and outside of the tank, respectively.
3.2.2. Validation for the 0D1D Model
The data on the initial/boundary conditions, the geometry and the physical properties of a 40 L Type III tank in Ref. [16] are used for model verification, as shown in Table 2 and Table 3.
Table 2.
The different initial and boundary conditions.
Table 3.
Geometry and physical properties of the 70 MPa tank.
In our earlier study, Ref. [17], the 0D1D model was thoroughly validated. As shown in Figure 2 of Ref. [17], the simulation results demonstrate good consistency with the experimental data. The maximum temperature difference between the simulated and experimental values during the filling process is about 5 °C. The final hydrogen temperature is very consistent, indicating that our 0D1D model is reliable.
4. New Filling Method
4.1. Polynomial Equation of Pressure Target
Due to and , Equation (3) for the pressure target can be rewritten as
Once is specified at the initial moment of filling, the final hydrogen temperature can be calculated by Equation (14), and the target hydrogen pressure can be calculated by Equation (20). The specific form of Equation (20) can be constructed as a polynomial, namely
where , and represent the density, temperature and pressure of hydrogen, respectively, and and are the parameters. When N ranges from 1 to 4, the R2 values are all below 0.99. When N = 5, R2 reaches 0.998, indicating that the polynomial equation fits the simulation data sufficiently well. Considering computational efficiency, we set N = 5. When N = 5, the specific form of Equation (21) can be expressed as [18]
To determine the parameters in Equation (22), this study conducted fitting calculations using physical property data from the National Institute of Standards and Technology (NIST) database [19]. The temperature range for hydrogen was set from 223.15 K to 373.15 K with a step size of 2 K, while the pressure varied from 0.1 MPa to 100.1 MPa with a step size of 2 MPa. By combining different temperature and pressure conditions, a total of 3876 independent hydrogen temperature–pressure data pairs were obtained. Calculations based on the NIST database were performed on these data pairs to derive the corresponding (P, T, ρ) dataset. This dataset was then used to fit Equation (22), and the resulting parameter values are reported in our earlier study (Ref. [18]).
4.2. Analytical Solution of Final Filling Time
Equations (4) and (5) originate from the original MC method and are used to derive the analytical solution of the final filling time for the new filling method. Therefore, the final hydrogen temperature in Equation (4) is treated as a known parameter, while the final filling time in Equation (5) is treated as the unknown variable. By combining Equations (4) and (5), the analytical solution of the final filling time can be solved as
During hydrogen refueling, the energy stored in the tank increases with the filling time, leading to a monotonic increase in the final hydrogen temperature as a function of the final filling time. As shown in Figure 1, the control logic of the original MC method can be expressed as Tfinal = f(tfinal), which is monotonically increasing. According to SAE J2601, this function is subject to the constraints tfinal ≥ 30 and Tfinal ≥ 0. In the proposed method, Equation (23), tfinal = f(Tfinal), is derived from Equations (4) and (5). Since it is the inverse of a monotonically increasing function, it preserves monotonicity and should therefore be subject to the same constraints of Tfinal ≥ 0 and tfinal ≥ 30. Regarding numerical robustness, Equation (23) contains logarithmic and exponential terms that may approach singularities under extreme conditions. To prevent overflow, inputs are clipped to ϵ = 10−10 and validated against SAE J2601 constraints and the verified parameter range (Ta from 0 to 20 °C, Tc from −20 to 0 °C). Boundary testing confirms no computational failures, demonstrating excellent stability on embedded platforms. In Equation (23), the final hydrogen temperature can be calculated by Equation (14). is unknown and needs to be calculated in advance. From the energy conservation of hydrogen, we know that
where , , . is the average enthalpy of hydrogen inflow during the filling process, which can be solved by the following method [5], that is
where h is the specific enthalpy of hydrogen, which is a function of temperature and pressure, and can be calculated using a bivariate polynomial in temperature and pressure [5]. is the precooling temperature of hydrogen; ; and and are the initial and final hydrogen pressures inside the tank. In this article is equal to , which can be calculated by Equation (20) in advance. and are the pressure drop between the vehicle tank and dispenser at the initial and final moments. Powertech testing shows with the tank’s initial pressure of 2 MPa. 2 MPa with an initial pressure of 17 MPa. 1 MPa at higher initial pressures, and is assumed to be 1 MPa in all cases. So is only evaluated using the initial and target station pressures (via Equation (25)), and no iteration is needed because the detailed pressure ramp is not needed. Therefore, at the initial moment of filling, the average enthalpy, adiabatic internal energy, and final filling time of hydrogen can be sequentially and explicitly solved using Equations (23)–(25), without the need for iteration. So, Equation (23) is an explicit closed-form expression based on an approximate quadrature for that is consistent with the MC method, not an exact analytical solution in the strict sense of the word.
4.3. Control Logic for the New Filling Method
Section 3.1.3 derives a new analytical solution of the final hydrogen temperature, Equation (14). Subsequently, by inversely deriving from Equations (4) and (5) of the MC method, a new analytical solution of the final filling time is obtained in Equation (23) (treating the final hydrogen temperature in Equation (4) as known and the final filling time in Equation (5) as unknown). For the new filling method, first, based on the station and vehicle parameters obtained from the HRS sensors, including initial hydrogen temperature T0 and pressure P0, precooling temperature Tc, ambient temperature Ta, specific heat capacities of the tank and hydrogen, etc., can be calculated using the gas equation of state, can be calculated by , can be calculated by Equation (14), Ptarget can be calculated by Equation (20), can be calculated by Equation (23), and then PRR can be calculated by Equation (1).
In comparing Figure 1 and Figure 3, our new filling method essentially uses the new analytical solution of the final hydrogen temperature Equation (14) to replace Equation (4), and uses the new analytical solution of the final filling time Equation (23) to replace Equation (2) of the original MC method. Equation (2) is obtained by fitting extensive simulation data, with its coefficients (a, b, c, and d) being functions of the ambient temperature, tank volume and initial pressure. SAE has established specific tables for these coefficients to facilitate queries during actual use. As shown in Figure 3, according to the filling control logic and the parameters provided by the vehicle and the station, the final hydrogen temperature is calculated directly and mathematically through Equation (14), and then the final filling time is calculated directly and mathematically through Equation (23). Equation (23) is derived by combining Equations (4) and (5) in the original MC method, with the coefficients being constants, specifically AC = 1.10487, BC = 2.20466, GC = 22.2198, KC = 0.00163097, and JC = 0.823284, as provided in the SAE J2601 protocol [2]. Equation (23) of the new filling method adopts constants from SAE to replace the curve-fitted coefficients used in Equation (2) of the original MC method. Therefore, from an implementation standpoint, Equation (23) can be considered more straightforward to apply in practice than Equation (2). In short, the new filling method is a computationally efficient analytical approximation of the MC method, representing an algorithmic simplification.
Figure 3.
The control logic of the new filling method proposed in this article.
4.4. Result Comparison of New Filling Method and 0D1D Model
To verify the effectiveness of our proposed new filling method, the ambient temperature is set to 0 and 20 °C; the precooling temperature is set to −20, −10 and 0 °C; and the initial pressure is set to 2, 6 and 10 MPa. The ranges of these parameters correspond to the typical operating conditions observed in practical HRS. Under 18 combined operating conditions, the proposed new filling method and the 0D1D model were executed, respectively, and their results were compared. The 0D1D model has been validated in Section 3.2, so its results can be regarded as accurate and used as a standard.
Figure 4 and Figure 5 show that, across different initial pressures and ambient temperatures, both the final hydrogen temperature and pressure increase as the precooling temperature rises. This phenomenon aligns with physical analysis: a higher precooling temperature leads to greater enthalpy entering the storage tank, resulting in greater energy accumulation in the tank and, consequently, a higher final hydrogen temperature and pressure. Similarly, under different precooling temperatures and initial pressures, the final hydrogen temperature and pressure also increase with a rising ambient temperature. This trend is consistent with physical principles: a higher ambient temperature reduces the temperature difference between the tank and the environment, thereby decreasing heat loss from the tank and leading to a higher final temperature and pressure. Furthermore, under different precooling and ambient temperatures, the final hydrogen temperature and pressure decrease as the initial pressure increases. This observation is also consistent with physical reasoning: a higher initial pressure means more residual hydrogen remains in the tank, resulting in less actual hydrogen being injected during the filling process, less energy being introduced, and thus a lower final temperature and pressure. In summary, these results also demonstrate the effectiveness of the new filling method. Figure 4 shows that, within the entire range of boundary conditions investigated in this study (ambient temperature from 0 to 20 °C, precooling temperature from −20 to 0 °C, and initial pressure from 2 to 10 MPa), the maximum final hydrogen temperature simulated by the new method occurs under the most severe operating condition: an ambient temperature of 20 °C, a precooling temperature of 0 °C, and an initial pressure of 2 MPa. This peak temperature is 61.5 °C, which is 23.5 °C lower than the safety threshold of 85 °C, thereby validating the safety of the proposed method within the studied range.
Figure 4.
Comparison of final hydrogen temperature between the new filling method and 0D1D model under different initial pressures P0, precooling temperature Tc and ambient temperature (a) Ta = 0 °C, (b) Ta = 20 °C.
Figure 5.
Comparison of final hydrogen pressure between the new filling method and 0D1D model under different initial pressures P0, precooling temperature Tc and ambient temperature (a) Ta = 0 °C, (b) Ta = 20 °C.
Figure 6 shows that the SOC of the new filling method varies only slightly across different ambient and precooling temperatures and increases with increasing initial pressure. At an ambient temperature of 20 °C and an initial pressure of 10 MPa, the final SOC exceeds 1. This is because during the simulation process in this research, both the 0D1D model and the new filling method were run simultaneously and stopped when the target SOC of the 0D1D model reached 1. This was only the simulation scenario established for this research. In future practical applications of the new filling method, the target SOC will be set to a value not exceeding 1, and filling will automatically stop once this target SOC is reached, thereby completely eliminating the risk of overcharging.
Figure 6.
Comparison of SOC between the new filling method and 0D1D model under different initial pressures P0, precooling temperature Tc and ambient temperature (a) Ta = 0 °C, (b) Ta = 20 °C.
Figure 5 shows that the final hydrogen pressure calculated by the new filling method is in excellent agreement with the 0D1D model results. In contrast, deviations are observed in the final hydrogen temperature and SOC in Figure 4 and Figure 6. Therefore, a further analysis of their specific errors was conducted.
Figure 7 and Figure 8 illustrate the errors in the final hydrogen temperature and SOC between the new filling method and the 0D1D model, respectively. Intuitively, at an initial pressure of 2 MPa, ambient temperature of 0 °C and precooling temperature of −20 °C, the error in the final hydrogen temperature is the largest at 4.3 °C, and the error in the SOC reaches its peak at 0.9%. According to the comparative validation results in Section 3.2.2, the maximum error in the final hydrogen temperature simulated by the 0D1D model, relative to experimental data, is approximately 5 °C, while the maximum error between the new filling method and the 0D1D model is about 4.3 °C. It can thus be inferred that the upper limit of the cumulative error between the new method and the experimental data is approximately 9.3 °C. To ensure a sufficient safety margin in practical applications, the safety threshold for the final hydrogen temperature can be set to 75.7 °C (i.e., 85 °C minus 9.3 °C). As shown in Figure 4, across the entire range of boundary conditions investigated in this study, the peak final hydrogen temperature simulated by the new method is 61.5 °C, which remains substantially below the safety threshold of 75.7 °C, further validating the safety of the proposed method under the studied operating conditions. To identify which parameter (ambient temperature, precooling temperature, and initial pressure) has more impact on the accuracy of the new filling method, we conducted a further parameter sensitivity analysis.
Figure 7.
Error of final hydrogen temperature between the new filling method and 0D1D model under different initial pressures, ambient and precooling temperatures.
Figure 8.
Error of final SOC between the new filling method and 0D1D model under different initial pressures, ambient and precooling temperatures.
Under various combinations of initial pressures and ambient temperatures, the errors in the final hydrogen temperature and SOC calculated by the new filling method and the 0D1D model change only slightly as the precooling temperature changes (all curves remain nearly horizontal), indicating that the precooling temperature has little effect on the computational accuracy of the new filling method. Under various combinations of precooling temperatures and initial pressures, as the ambient temperature changes, the maximum absolute error (MAE) in the final hydrogen temperature is 1.7 °C, and the MAE in SOC is 0.39% (comparison between curves of the different symbols with the same color), indicating that ambient temperature has a moderate effect on the computational accuracy of the new filling method. Under various combinations of ambient and precooling temperatures, as the initial pressure changes, the MAE in the final hydrogen temperature is 5.0 °C, and the MAE in SOC changes is 1.1% (comparison between curves of the same symbol with different colors), indicating that initial pressure has the most significant effect on the computational accuracy of the new filling method.
We further define the normalized coefficient , where is 100% for SOC and 85 °C for the final hydrogen temperature. For the SOC error, initial pressure (2 to 10 MPa) yields ΔE = 1.1%FS (S = 0.0110), 2.8 times that of ambient temperature and 12 times that of precooling temperature. For the temperature error, the initial pressure gives ΔE = 5.0 °C (S = 0.0589), which is 2.9 times that of the ambient temperature and 13 times that of the precooling temperature. Initial pressure is the most sensitive parameter, followed by ambient temperature, while precooling temperature shows the weakest influence. This one-factor-at-a-time-based analysis identifies main effects; interaction effects will be studied in future work.
In future work, the correction factors regarding the initial pressure and ambient temperature can be introduced to improve the accuracy of our new filling method further. For example, we can implement in Equation (1) , where k1 and k2 are the correction factors. In the MC method, the parameters AC, BC, GC, KC and JC in Equation (5) are determined based on the conservative “cold tank” assumption [2]. Consistently, the correction factors k1 and k2 can be calibrated following the same principle, conducting simulations using the “cold tank” parameters. Based on thermodynamic principles, variations in ambient temperature affect the final hydrogen temperature, which in turn directly determines the target pressure, as illustrated in Figure 3. Therefore, the correction factor for ambient temperature can be indirectly coupled into the calculation of the target pressure.
5. Conclusions
This article derives analytical solutions of the final filling time and hydrogen temperature using an established lumped-parameter model of the storage tank and proposes a new filling method based directly on these solutions. The simulation results of the new filling method and the validated 0D1D model are compared. Under the ambient temperature condition of 0–20 °C and precooling temperature condition of −20–0 °C set in this article, the specific conclusions of this article are as follows:
- (1)
- Compared with the simulation results of the 0D1D model, the new filling method demonstrates maximum errors of 4.3 °C in the final hydrogen temperature and 0.9% in the SOC, indicating a certain degree of effectiveness of the new method.
- (2)
- Compared to the ambient and precooling temperatures, initial pressure has the most significant effect on the computational accuracy of the new filling method. In future work, the correction factors for the initial pressure and ambient temperature can be introduced further to improve the accuracy of the new filling method. This study adopts a one-factor-at-a-time approach to identify main effects, while interaction effects will be investigated in future work.
- (3)
- Because the analytical solution of the final hydrogen temperature includes the precooling temperature, the new filling method can also automatically respond to the precooling temperature.
The filling method proposed in this article has been validated using a 0D1D model simulation, which focused on the most widely applied range (ambient temperature: 0 to 20 °C; precooling temperature: −20 to 0 °C) and demonstrated reasonable accuracy. Further experimental validation and broader verification, including the range for HRS specified in SAE J2601/2 (ambient temperature of −40 to 50 °C and a minimum precooling temperature of −40 °C), will be conducted in subsequent work.
Author Contributions
Conceptualization, J.X.; methodology, T.Y. and C.L.; software, X.W. (Xu Wang); validation, S.D.; formal analysis, C.L.; investigation, T.Y.; resources, S.D. and J.X.; data curation, X.W. (Xu Wang); writing—original draft preparation, S.D. and H.L.; writing—review and editing, H.L. and T.Y.; visualization, X.W. (Xianhuan Wu); supervision, J.X.; project administration, H.L. and X.W. (Xianhuan Wu); funding acquisition, H.L. and S.D. All authors have read and agreed to the published version of the manuscript.
Funding
This research are funded by the 2024 China University-Industry-Research Innovation Fund (2024IT275) and the Natural Science Foundation of Hubei Province of China (2024AFC069).
Data Availability Statement
The data are contained within this article.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| MAT | Mass average temperature |
| MC | Mass capacity |
| NWP | Nominal working pressure |
| NIST | National Institute of Standards and Technology |
| PRR | Pressure ramp rate |
| SAE | Society of Automotive Engineers |
| SOC | State of charge |
| HRS | Hydrogen refueling station |
| 0D1D | Zero-dimensional gas and one-dimensional tank wall |
References
- Cosso, S.; Benevieri, A.; Passalacqua, M.; Formentini, A.; Vaccaro, L.; Kissling, S.; Carpita, M.; Marchesoni, M. Energy Storage Configuration in Fuel Cell Electric Vehicle: An Analysis on a Real Urban Mission Profile. Energies 2025, 18, 6136. [Google Scholar] [CrossRef] [Scilit]
- SAE J2601; Fueling Protocols for Light Duty Gaseous Hydrogen Surface Vehicles. SAE International: Warrendale, PA, USA, 2020.
- Schneider, J.; Meadows, G.; Mathison, S.; Veenstra, M. Validation and Sensitivity Studies for SAE J2601, the Light Duty Vehicle Hydrogen Fueling Standard. SAE Int. J. Alt. Power 2014, 3, 257–309. [Google Scholar] [CrossRef] [Scilit]
- Mathison, S.; Handa, K.; McGuire, T.; Brown, T.; Goldstein, T.; Johnston, M. Field Validation of the MC Default Fill Hydrogen Fueling Protocol. SAE Int. J. Alt. Power 2015, 4, 130–144. [Google Scholar] [CrossRef] [Scilit]
- Harty, R.; Mathison, S. Improving Hydrogen Tank Refueling Performance Through the Use of an Advanced Fueling Algorithm—The MC Method. In Proceedings of the NHA Hydrogen Conference & Expo, Long Beach, CA, USA, 3–6 May 2010. [Google Scholar]
- Mathison, S.; Harty, R.; Cohen, J. Application of MC Method-Based H2 Fueling. In Proceedings of the SAE 2012 World Congress & Exhibition, Detroit, MI, USA, 24–26 April 2012. [Google Scholar]
- Chae, C.K.; Park, B.H.; Huh, Y.S.; Kang, S.Y.; Kang, S.Y.; Kim, H.N. Development of a new real time responding hydrogen fueling protocol. Int. J. Hydrogen Energy 2020, 45, 15390–15401. [Google Scholar] [CrossRef] [Scilit]
- Reddi, K.; Elgowainy, A.; Rustagi, N.; Gupta, E. Impact of hydrogen SAE J2601 fueling methods on fueling time of light-duty fuel cell electric vehicles. Int. J. Hydrogen Energy 2017, 42, 16675–16685. [Google Scholar] [CrossRef] [Scilit]
- Chochlidakis, C.G.; Rothuizen, E.D. Overall efficiency comparison between the fueling methods of SAEJ2601 using dynamic simulations. Int. J. Hydrogen Energy 2020, 45, 11842–11854. [Google Scholar] [CrossRef] [Scilit]
- Lv, H.; Su, Y.; Huang, G.; Zhang, Q.; Zhang, C. Research on rapid refueling of Type-IV hydrogen storage tanks for hydrogen-powered heavy-duty commercial vehicles. Renew. Energy 2025, 253, 123673. [Google Scholar] [CrossRef] [Scilit]
- Handa, K.; Yamaguchi, S.; Rembutsu, T.; Akami, Y.; Nakanishi, I. Hydrogen refueling method for heavy-duty FCV with pressure loss compensation. Int. J. Hydrogen Energy 2024, 66, 223–230. [Google Scholar] [CrossRef] [Scilit]
- Martorelli, M.; Genovese, M.; Fragiacomo, P. Enhancing heavy duty vehicle hydrogen refueling by alternative approach to SAE J2601/2 protocol and flow dynamics. Int. J. Hydrogen Energy 2025, 101, 234–249. [Google Scholar] [CrossRef] [Scilit]
- Wang, X.; Hui, C.; Liu, D.; Deng, S.; Sui, P.-C. Optimization of Inlet Hydrogen Temperature during the Fast-Filling Process Based on a Back Propagation Neural Network Model. Energies 2024, 17, 1569. [Google Scholar] [CrossRef] [Scilit]
- Rothuizen, E.; Mérida, W.; Rokni, M. Optimization of hydrogen vehicle refueling via dynamic simulation. Int. J. Hydrogen Energy 2013, 38, 4221–4231. [Google Scholar] [CrossRef] [Scilit]
- Bourgeois, T.; Ammouri, F.; Weber, M.; Knapik, C. Evaluating the temperature inside a tank during a filling with highly-pressurized gas. Int. J. Hydrogen Energy 2015, 40, 11748–11755. [Google Scholar] [CrossRef] [Scilit]
- de Miguel, N.; Ortiz Cebolla, R.; Acosta, B.; Moretto, P.; Harskamp, F. Compressed hydrogen tanks for onboard application: Thermal behaviour during cycling. Int. J. Hydrogen Energy 2015, 40, 6449–6458. [Google Scholar] [CrossRef] [Scilit]
- Luo, H.; Xiao, J.; Bénard, P.; Zong, Y.; Chahine, R.; Tong, L.; Yuan, C.; Yang, T.; Yuan, Y. Optimal estimation of MC parameter in SAE J2601 hydrogen refuelling protocol based on modified formula and artificial neural networks. Fuel 2024, 365, 131315. [Google Scholar] [CrossRef] [Scilit]
- Luo, H.; Xin, Q.; Yao, C.; Li, C.; Yang, T.; Wu, X.; Chahine, R.; Xiao, J. Effect of real gas equations on calculation accuracy of thermodynamic state in hydrogen storage tank. Appl. Sci. 2025, 15, 11151. [Google Scholar] [CrossRef] [Scilit]
- Lemmon, E.W.; Bell, I.H.; Huber, M.L.; McLinden, M.O. NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP. Available online: https://www.nist.gov/srd/refprop (accessed on 10 December 2025).
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.