Integrated Hydroponic Bioelectrochemical Wastewater Treatment Process for Sustainable Agriculture †

,
and
1
School of Sustainability Engineering and Environmental Engineering, Purdue University, West Lafayette, IN 47907, USA
2
Purdue University Northwest Water Institute, Purdue University Northwest, Hammond, IN 46323, USA
3
Department of Mechanical and Civil Engineering, Purdue University Northwest, Hammond, IN 46323, USA
*
Authors to whom correspondence should be addressed.

Abstract

As the global population grows rapidly, effective wastewater management and resource recovery is increasingly critical. Conventional wastewater treatment is energy-intensive, and it increases reliance on fossil fuel supplies. Microbial Electrochemical Systems (MES) offer a sustainable alternative by treating wastewater and producing renewable electricity. This study evaluates a combined MES–hydroponic system facilitating Lactuca sativa growth in cathodes via nutrient transport across a cation exchange membrane (CEM) from municipal wastewater being treated in the anode chamber. The system achieved 56 ± 11% COD removal, 48 ± 21% N removal, 4.32 mW/m2 peak power density, and a 25% increase in plant wet weight. In contrast, a standard air-cathode cell had 60 ± 15% COD removal, 55 ± 20% N removal, and 0.29 mW/m2 peak power density. Findings demonstrate the potential of combined MES–hydroponic systems for wastewater treatment and agriculture in a circular economy framework.

1. Introduction

As the global population increases, having exceeded 8 billion people in 2022 [1], the treatment of wastewater, particularly municipal (domestic) wastewater, must be included in modern efforts to achieve ecological balance. When directly discharged into natural waters, untreated wastewater effluents raise concentrations of nutrients, minerals, and biomass in water bodies, causing serious harm to marine and freshwater ecosystems through eutrophication and other processes. Hence, wastewater must be treated prior to release. However, conventional municipal wastewater treatment is energy-intensive, representing 2–3% of the total energy consumption in the United States [2]. This, in turn, contributes to demand for fossil fuels, which produce greenhouse gases that exacerbate global warming [3]. Thus, efficiency and sustainability in treatment operations is a major contemporary research focus. Indeed, the chemical energy stored in wastewater (specifically nutrients and carbonaceous compounds) can be harnessed to power its own treatment.
To this end, bioelectrochemical systems have been studied for their potential to treat wastewater and generate renewable energy simultaneously. The Microbial Electrochemical System (MES) is a type of bioelectrochemical system (BES) that operates like a Galvanic battery [2]. Essentially, it is made up of an anode chamber, which accepts substrates like wastewater as the analyte, a semipermeable membrane (anion exchange, proton exchange, or cation exchange), and a cathode chamber, which usually accepts air or water as the catholyte. Electroactive bacteria (EAB) in the anode chamber, either introduced via inoculation or as part of the analyte, oxidize pollutants and transfer those electrons to the anode. The electrons then travel through a metallic wire, an external resistor, and end up in the cathode. With a cation exchange membrane, protons (H+) generated during oxidation at the anode travel across the membrane to the cathode chamber. Here, oxygen is reduced to water. This innovative technology shows promise for sustainable wastewater treatment and is being extensively investigated to increase power production, coulombic efficiency, pollutant removal efficiency, cost-effectiveness, and scalability, among other aspects [2]. This is demonstrated in Figure 1.
Figure 1. A Microbial Electrochemical System using a microbial fuel cell configuration—the anode compartment is fed with wastewater while the cathode compartment is exposed to the ambient.
While there are many ways to improve the performance of microbial fuel cells, the presence of strong catalytic activity in the cathode is critical to enhance their power generation potential. In this research, we study the effect of a hydroponic nutrient solution as a catholyte on the performance of a microbial fuel cell treating municipal wastewater from a local plant. The growing population also creates a growing demand for healthy, sustainably grown food. Hydroponics is an agricultural approach wherein edible plants are grown without soil using a nutrient solution [4]. Not only does this form of agriculture conserve water and energy due to its consolidated design, but it is also adaptable to urban environments, where residents, especially low-income populations, lack access to fresh produce and healthy foods. A hydroponics system can be conveniently integrated into the microbial electrochemical system’s process scheme to exploit the synergistic benefits from the two distinguishing technological platforms [5]. Many studies have demonstrated the potential for electricity and fertilizer production [6,7]. Some studies have focused on the effect of membranes [8] as well as the effect of using microalgae for pH control [9]. It was shown that the bio- and physico-chemical parameters of the system can be tailored to the different types of plants grown in the hydroponics unit; each plant has its own requirements. While these studies explored the potential of the integrated process, the use of actual wastewater to delineate the performance of the integrated process has not been studied so far. Synthetic wastewater or a specific nutrient source, such as urine, has been used as an anode or catholyte [6]. There is a significant knowledge gap in the understanding of the effect of real wastewater in the anode compartment and, similarly, of a hydroponic nutrient medium in the cathode compartment. As it has been shown that hydroponic setups can aid in and benefit from the processes of a microbial electrochemical system, this research aims to harness the untapped chemical energy in real wastewater using an integrated microbial electrochemical system (MES) configuration while boosting crop growth in the hydroponic system.

2. Materials and Methods

2.1. Standard Air-Cathode MES

The following configuration was used to develop a biofilm for the hydroponic MES configuration and analyze the feasibility of low-cost, environmentally friendly materials in power generation. Four such reactors were evaluated simultaneously. Each was composed of an anode chamber and a cathode chamber housing carbon felt electrodes connected with titanium wire to facilitate electron flow. The thickness of the felt was 1 cm, with the following dimensions: 5 cm × 3 cm × 1 cm. Carbon-based electrodes possess several properties that are desirable in an MES, including high electrical conductivity (EC), chemical stability, porosity, and biocompatibility [5]. Moreover, they are inexpensive, especially compared to the metallic electrodes used in several studies [5]. The chambers were separated by a cation exchange membrane (CEM, Membrane International Inc., Ringwood, NJ, USA). This setup can be seen in Figure 2.
Figure 2. Standard air-cathode reactor.
Distilled water was used as the catholyte in an aerobic cathode chamber. Aeration was determined to have a negligible effect on performance and was not utilized. The anolyte was filled with 100 mL of municipal wastewater from the primary treatment effluent (Portage Wastewater Treatment Plant, Portage, IN, USA), double-filtered through 0.42 µm filters. During the first startup cycles (16 days), 20 mL of oxidation ditch sludge was added to the anode to promote microbial inoculation and rapid biofilm formation.

2.2. Integrated Hydroponic–MES

This reactor (Figure 3) used the same anode and electrode setup and is mainly different in its building material and cathode setup. The anode chamber features outlets that enable easy sampling of the anolyte, while the cathode chamber is completely open on top. This reduces the system disruptions that can occur when a syringe is repeatedly inserted into each chamber until the desired sample amount for testing (approximately 15 mL) is acquired. The cathode chamber includes ledges for a mesh or other platform on which plants can be placed. These were 3D-printed using PETG filament, making them a highly modifiable and inexpensive alternative to traditional materials.
Figure 3. Integrated hydroponic-microbial fuel cell system.
Fluke Connect (v1.26.6.774) was used to view and transfer data from multimeters to a computer in .csv file format. Excel was then used to generate combination graphs for each experiment (containing trends for all reactors for a particular nutrient). A Python (version 3.13.1) program was developed to graph continuous voltage data collected by the multimeter.
The polarization test was performed after the open-circuit voltage (OCV) had stabilized, and then external resistance was sequentially adjusted to 10, 100, 500, 1000, 2000, 5000, 10,000, 20,000, and 50,000 Ω, maintaining each load for 15 min.

2.3. Calculations

Current was calculated by
I = V R e x t
where V is the voltage (V) produced by the MEC and R e x t is the external resistance (Ω) (either of a color-coded resistor or variable resistor).
Coulombic efficiency (CE) was calculated by [10].
C E = M ∫ I d t F b V a n ∆ C O D ≈ M I a v g t F b V a n ∆ C O D ∗ 100 %
where I a v g is the average current (A), t is time (seconds), M is the molecular weight of the terminal electron acceptor (O2 in this case) (g/mol), F is Faraday’s constant (96485 C/mol), b is the number of electrons exchanged per mole of TEA (4 e− per mole here), V a n is the volume of the anode solution (L), and ∆ C O D is the amount of COD removed (g/L).
Power density (PD) was calculated by
P D = V 2 R e x t A
where V is the voltage (V) produced by the MEC, R e x t is the external resistance (Ω), and A is the area of the anode or the combined area of both electrodes (m2). The latter may be more representative of the system; using the area of one electrode could be misleading [11].
Removal efficiency (E) of a pollutant x was calculated using
E = C 0 − C t C 0 ∗ 100 %
where C 0 and C t are the initial and time-dependent (i.e., final) concentrations of x, respectively.

3. Results

3.1. Polarization

Figure 4 and Figure 5 depict the results of polarization for the standard and integrated setups, respectively. Current and power measured throughout the experiments are divided by the surface area of the anode, which is 0.0046 m2.
Figure 4. Polarization curves for the standard air-cathode setup.
Figure 5. Polarization curves for the integrated setup.
There is a clear improvement in both power density and voltage output for the integrated setup. In Figure 4, the standard air-cathode shows a rapid initial voltage drop indicative of activation polarization, followed by a linear decline due to ohmic losses, yielding a narrow power density peak of 0.29 mW/m2 at low current densities between 1 and 5 mA/m2. In contrast, Figure 5, depicting the integrated setup, shows a steeper but shorter activation region, then a more sustained voltage profile with a reduced slope, enabling much higher current densities of up to 100 mA/m2 and a broader, elevated power density peak near 4.32 mW/m2. The 15-fold improvement of the integrated setup affirms the system’s superiority for scalable power output.

3.2. Nutrient Analyses

Influent concentrations of wastewater varied among experimental cycles due to day-to-day fluctuations in quality (as occurred at the wastewater treatment plant), which caused corresponding changes in total nitrogen and chemical oxygen demand loading and led to cycle-to-cycle differences in removal efficiency for both configurations. Figure 6a,b show that the wastewater-fed anode compartments of the integrated and air-cathode systems both achieved effective total nitrogen removal across the experimental period. Figure 6c,d indicate that the COD concentrations of both systems declined markedly. This confirmed the robust organic matter degradation under variable influent conditions.
Figure 6. Nutrient removal trends in the anode chamber during the ten cycles of the operating period (a) Total Nitrogen (TN) of the integrated system; (b) Total Nitrogen (TN) of the air-cathode system; (c) COD of the integrated system; (d) COD of the air-cathode system; (e) ammonia of the integrated system; (f) ammonia of the air-cathode system.

4. Discussion

4.1. Nitrogen Removal

The nitrogen removal may have occurred due to the biological nitrification and subsequent denitrification process. There was sufficient DO in the anode (it was always greater than 1 mg/L and hence not truly anaerobic) to nitrify bacteria and perform conversion from ammonia (NH4+) to nitrate (NO3−), at least to some extent, as explained by Zhao et al. in their review of N removal in MFCs [12]. This NO3− would then have been converted to nitrogen gas (N2), an environmentally harmless molecule that is naturally present in the atmosphere [13]. Another mechanism of concentration decrease may have been the migration of NH4+ across the CEM into the cathode, as the pH was low enough to prompt an equilibrium shift toward ammonia (see Equation (5)), according to Le Chatelier’s principle. The two species exist at equal concentrations at a pH of 9.25 [14].
N H 3 + H 2 O ⇌ N H 4 + + O H −
As shown in Figure 6e,f, the integrated setup exhibited consistent ammonium removal, with an average recovery of 48%, indicating active nitrogen transformation. Elevated dissolved oxygen in the anode in both configurations supported aerobic ammonia oxidation. The stable pH indicated that ammonium removal was not driven by pH-induced ammonia volatilization but rather by biologically mediated processes and membrane-driven ion transport. Alternatively, bacteria in the anolyte may have assimilated ammonium into their proteins and DNA, as both of these cell-building macromolecules contain nitrogen. Other, less likely pathways are adherence to suspended solids in the anolyte, the partitioning of gaseous (not aqueous) NH3 such that bubbles form in the space above the anolyte in the chamber, and precipitation with cations.

4.2. Phosphate Removal

Due to the use of a CEM, P O 4 3 − levels were not expected to significantly change, which is supported by the writing of Ramirez-Nava et al. [15]. This is mainly because CEM only allows for the transfer of cations across the membrane, and P O 4 3 − cannot be oxidized further as phosphorus is already in its highest oxidation state of +5. Indeed, in one trial, when an AEM was used in place of a CEM, P O 4 3 − removal from the anode was 100%. With a CEM, a majority of the interactions involving P O 4 3 − would have been contained within individual chambers. A rise in concentrations could be caused by the leaching of P O 4 3 − into the anolyte from the sludge matrix [16]. Also, the death of microbes from the biofilm (biofilm breakdown), sludge matrix, or those suspended in the anolyte could trigger increases [16]. If cell death occurs, phosphate within the cells, cell membranes, or the adenosine triphosphate (ATP, an energy storage molecule) stored within cells could leach into the anolyte. The decreases could be explained by the assimilation of phosphorus by bacteria, which could use it to build and maintain cell membranes or produce adenosine triphosphate (ATP, an energy storage molecule) [17]. Another less likely reason for decreases could be the precipitation of phosphorus as struvite by the reaction in Equation (6), as illustrated by Paucar and Sato in their overview of the role of MFCs in nutrient removal [17]. Struvite (the final product) could precipitate due to the ammonium present in the wastewater at low pH and with magnesium (Mg) present as a trace metal (measured as part of TDS).
M g 2 + + N H 4 + + P O 4 3 − + 6 H 2 O ⇌ N H 4 M g P O 4 · 6 H 2 O

4.3. COD Removal

COD removal in both systems can be attributed primarily to the biodegradation of the organic matter inherently present in the municipal wastewater. The complex mixture of soluble and particulate organics, including proteins and volatile fatty acids, served as electron donors for electroactive microorganisms in the anode biofilm, resulting in a consistent reduction in COD as these substrates were metabolized and partially converted into electrons and protons. This study demonstrated that while both systems provided effective COD removal, the integrated configuration more effectively coupled organic oxidation to electricity generation, as evidenced by the higher voltage profiles in the integrated system.

5. Conclusions

This study evaluated the treatment performance and electrochemical behavior of two distinct configurations, a conventional air-cathode MES and an integrated MES–Hydroponic system. Despite differences in operational setup and cathodic environment, both systems showed comparable pollutant removal, suggesting that coupling a hydroponic plant does not compromise treatment efficiency. Moreover, integrated MES consistently produced a higher power output and density, proving that the presence of the hydroponic electrolyte, coupled with enhanced ionic transport across the membrane, supported more favorable cathodic kinetics and reduced overall system losses. This outcome highlights the potential of MES–Hydroponics, not only to treat wastewater, but also to recover energy. Future work will focus on quantifying the kinetics of organic matter removal, experimentally resolving internal resistance contributions from each reactor component, and examining plant performance under long-term integrated operation. These will help clarify how hydroponic cultivation responds to electrochemical interactions and support the advancement of integrated systems capable of simultaneous contaminant removal, nutrient recovery, and renewable energy generation.

Author Contributions

Conceptualization, N.A.M., K.T.T. and V.G.G.; methodology, K.T.T. and V.G.G.; validation, N.A.M., K.T.T. and V.G.G.; formal analysis, N.A.M., K.T.T. and V.G.G.; investigation, N.A.M., K.T.T. and V.G.G.; resources, V.G.G.; data curation, N.A.M. and K.T.T.; writing—original draft preparation, N.A.M. and K.T.T.; writing—review and editing, N.A.M., K.T.T. and V.G.G.; visualization, N.A.M. and K.T.T.; supervision, V.G.G.; project administration, V.G.G.; funding acquisition, V.G.G. All authors have read and agreed to the published version of the manuscript.

Funding

This work is supported by the competitive grants, REEU program, [grant no. 2023-68018-40325], WAMS program [grant no. 2023-38503-41313], and HSI program [2024-77040-43780], from the U.S. Department of Agriculture, National Institute of Food and Agriculture. Any opinions, findings, conclusions, or recommendations expressed in this publication are those of the author(s) and should not be construed to represent any official USDA or U.S. Government determination or policy.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors on request.

Acknowledgments

The authors gratefully acknowledge David McLees (PNW College of Technology) for assistance with the 3D-printed reactors used in this study. The authors also acknowledge support from the NiSource–Meyer Foundation Professor of Energy and the Environment Professorship and the Purdue University Northwest Water Institute.

Conflicts of Interest

The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

References

  1. United Nations. Day of 8 Billion. Available online: https://www.un.org/en/dayof8billion (accessed on 26 January 2026).
  2. Gude, V.G. Wastewater treatment in microbial fuel cells—An overview. J. Clean. Prod. 2016, 122, 28–307. [Google Scholar] [CrossRef] [Scilit]
  3. Kokabian, B.; Gude, V.G. Photosynthetic microbial desalination cells (PMDCs) for clean energy, water and biomass production. Environ. Sci. Process. Impacts 2013, 15, 2178–2185. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Wang, S.; Adekunle, A.; Raghavan, V. Exploring the integration of bioelectrochemical systems and hydroponics: Possibilities, challenges, and innovations. J. Clean. Prod. 2022, 366, 132855. [Google Scholar] [CrossRef] [Scilit]
  5. Prashanthi, R. A review on microbial fuel cell and green energy. Ionics 2023, 29, 1667–1697. [Google Scholar] [CrossRef] [Scilit]
  6. Nath, D.; Ieropoulos, I.A. Electricity and fertiliser production using microbial fuel cell stacks for possible integration with hydroponics. J. Power Sources 2025, 652, 237546. [Google Scholar] [CrossRef] [Scilit]
  7. Yadav, R.K.; Chiranjeevi, P.; Sukrampal; Patil, S.A. Integrated drip hydroponics-microbial fuel cell system for wastewater treatment and resource recovery. Bioresour. Technol. Rep. 2020, 9, 100392. [Google Scholar] [CrossRef] [Scilit]
  8. Khuman, C.N.; Bhowmick, G.D.; Ghangrekar, M.M.; Mitra, A. Effect of Using a Ceramic Separator on the Performance of Hydroponic Constructed Wetland-Microbial Fuel Cell. J. Hazard. Toxic Radioact. Waste 2020, 24, 04020005. [Google Scholar] [CrossRef] [Scilit]
  9. Yolanda, Y.D.; Kim, S.; Sohn, W.; Shon, H.K.; Yang, E.; Lee, S. Simultaneous nutrient-abundant hydroponic wastewater treatment, direct carbon capture, and bioenergy harvesting using microalgae–microbial fuel cells. Desalination Water Treat. 2024, 321, 100941. [Google Scholar] [CrossRef] [Scilit]
  10. Sato, C.; Apollon, W.; Luna-Maldonado, A.I.; Paucar, N.E.; Hibbert, M.; Dudgeon, J. Integrating Microbial Fuel Cell and Hydroponic Technologies Using a Ceramic Membrane Separator to Develop an Energy–Water–Food Supply System. Membranes 2023, 13, 803. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Schneider, K.; Thorne, R.J.; Cameron, P.J. An investigation of anode and cathode materials in photomicrobial fuel cells. Philos. Trans. R. Soc. A Math. Phys. Eng. Sci. 2016, 374, 20150080. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Zhao, J.; Wu, J.; Li, X.; Wang, S.; Hu, B.; Ding, X. The Denitrification Characteristics and Microbial Community in the Cathode of an MFC with Aerobic Denitrification at High Temperatures. Front. Microbiol. 2017, 8, 9. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Ahn, Y.-H. Sustainable nitrogen elimination biotechnologies: A review. Process. Biochem. 2006, 41, 1709–1721. [Google Scholar] [CrossRef] [Scilit]
  14. Hristov, A.N.; Hanigan, M.; Cole, A.; Todd, R.; McAllister, T.A.; Ndegwa, P.M.; Rotz, A. Review: Ammonia emissions from dairy farms and beef feedlots. Can. J. Anim. Sci. 2011, 91, 1–35. [Google Scholar] [CrossRef] [Scilit]
  15. Ramirez-Nava, J.; Martínez-Castrejón, M.; García-Mesino, R.L.; López-Díaz, J.A.; Talavera-Mendoza, O.; Sarmiento-Villagrana, A.; Rojano, F.; Hernández-Flores, G. The Implications of Membranes Used as Separators in Microbial Fuel Cells. Membranes 2021, 11, 738. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Bond, P.L.; Keller, J.; Blackall, L.L. Anaerobic phosphate release from activated sludge with enhanced biological phosphorus removal. A possible mechanism of intracellular pH control. Biotechnol. Bioeng. 1999, 63, 507–515. [Google Scholar] [CrossRef]
  17. Paucar, N.E.; Sato, C. Microbial Fuel Cell for Energy Production, Nutrient Removal and Recovery from Wastewater: A Review. Processes 2021, 9, 1318. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.