Abstract
Microfluidic paper-based analytical devices have broadened the scope of microfluidics by offering low-cost, simple, faster fabrication, biodegradability, and environmentally benign devices capable of medical diagnostics, environmental sensing, and food quality control. These devices are incredibly versatile, which is one of their most notable features. Despite recent advancements in paper-fluidics, creating slow flow channels in paper still remains a challenge. Herein, we propose viscous barriers of various concentrations embedded along the paper channel to control its flow velocity by altering the pore size. We used sugar concentrations in the range of 0–40% dried in porous media and then recorded flow behaviors of water and castor oil. From experiments, it was observed that by increasing the sugar concentration, delay time also increased. Moreover, changing the type of fluid (w.r.t viscosity) also varies the flow delays as castor oil took a much longer time to cover the same channel length as compared to water. We believe that our proposed method will play an important part in improving flow delays and can be applied for food quality applications such as time–temperature indicators due to its simple fabrication and cost-effective technique.