Skip to Content
  • Proceeding Paper
  • Open Access

18 November 2026

10 Pages

Lightweight Ordinal Learning for Diabetic Retinopathy Grading: Balancing Performance and Computational Efficiency †

,
and
1
Meridian Team, LyRICA Laboratory, School of Information Sciences, Rabat 10100, Morocco
2
Laboratoire Parcours Santé Systémique (P2S), EA 4129, Université Lyon 1, 69372 Lyon, France
*
Authors to whom correspondence should be addressed.
†
Presented at the 8th edition of the International Conference on Advanced Technologies for Humanity (ICATH 2026), Rabat, Morocco, 15–17 July 2026.

Abstract

Lightweight models are of growing interest for medical image analysis, particularly for screening contexts where specialised hardware is not always available. A fair comparison between such models and heavier baselines requires that every architecture be trained and evaluated under the same conditions, since differences in preprocessing, data splits, or training recipes can otherwise account for part of any observed gap. We compare eight architectures spanning 1.3 to 23.5 M parameters—six lightweight backbones (ShuffleNetV2, MobileNetV3-Small, EfficientNet-B0, MobileNetV3-Large, GhostNetV2, DeiT-Tiny) and two widely used references (DenseNet121, ResNet50)—on diabetic retinopathy (DR) grading using APTOS 2019 (3662 fundus images), with all models sharing the same five-fold stratified splits, CLAHE preprocessing, training recipe, and evaluation protocol, so that observed differences are attributable to the architectures. We additionally evaluate two ordinal regression objectives that encode the ordered structure of DR grades, where distant misclassifications carry a greater clinical cost than adjacent ones: ORCU, which targets a discretised Gaussian soft label with a unimodality penalty, and CORN, which uses K − 1 conditional binary heads. Averaged across the eight backbones, ORCU improves quadratic weighted kappa (QWK) by +0.010 and CORN by +0.011 over focal cross-entropy, with the largest gains on the most compact models (up to +0.021 for ShuffleNetV2 under CORN). MobileNetV3-Large with ORCU (4.2 M parameters, 0.891 QWK) reaches a mean QWK within 0.001 of the 23.5 M-parameter ResNet50 baseline, with 82% fewer parameters, 18× fewer multiply–adds, and 4.6× lower CPU inference latency. Taken together, these findings show how pairing a matched cross-architecture comparison with a shared loss axis provides practical guidance for choosing models in medical imaging pipelines operating under resource constraints.

1. Introduction

Medical image analysis increasingly relies on deep learning, with applications that span classification, segmentation, and grading across a variety of imaging modalities [1,2]. Models such as DenseNet121 [3], ResNet50 [4], and large EfficientNet variants [5] have set strong accuracy baselines, but they typically contain between 7 and 25 million parameters and require several gigaFLOPs per image. These requirements can be limiting in settings where specialised hardware is unavailable. This has motivated interest in lightweight models such as MobileNetV3 [6], ShuffleNetV2 [7], GhostNetV2 [8], and compact vision transformers like DeiT-Tiny [9], which reach competitive ImageNet performance at lower computational cost and are candidates for medical deployment pipelines.
A question that arises in practice is how lightweight models of different designs behave on a given medical grading task compared with conventional heavier baselines, under otherwise identical conditions. We do not aim to identify a single best lightweight model: the goal of this study is to characterise how a representative set of designs behaves in a matched setting. When different models are reported across different studies, comparisons are complicated by differences in preprocessing, data splits, loss functions, and augmentation. This motivates the present work: we apply several models under a single protocol on a concrete medical grading task and observe how they compare to each other and to conventional baselines.
Diabetic retinopathy (DR) grading serves as the demonstration task in this work because it constitutes a well-established and commonly adopted benchmark. Pooling studies published between 2017 and 2024, a worldwide meta-analysis reported that roughly 23% (95% CI: 20–26%) of adults living with diabetes present with some form of DR, and that sight-threatening disease affects 11% of them [10]. Although fundus photography is a routine method for early detection, the availability of qualified human graders is not uniform across regions and is especially limited in low- and middle-income settings [11]. Because the problem is supported by a publicly available dataset (APTOS 2019 [12]) together with a recognised evaluation metric (quadratic weighted kappa, QWK), it lends itself naturally to architecture-level comparison. Recent work has explored deep-learning approaches to DR grading from several angles, including hybrid CNN and attention-based pipelines [13,14], graph-enhanced models [15], variants based on vision transformers [16,17,18], two-stage lightweight frameworks [19], and hybrid quantum-classical networks [20]. Those studies are complementary to the present one: whereas each introduces a specific model or pipeline, the present study benchmarks a family of eight architectures under matched conditions, so that the influence of the architectural choice itself can be separated out.
A further consideration concerns the loss function. DR grading is ordinal: the five severity levels form an ordered scale, so a misclassification from Grade 0 to Grade 4 has a different clinical implication than one from Grade 0 to Grade 1. Standard cross-entropy treats all misclassifications equally, which does not reflect this structure. Two recent ordinal regression objectives take distinct approaches to this problem. CORN (Conditional Ordinal Regression for Neural networks [21]) decomposes the K-class ordinal problem into K − 1 conditional binary sub-tasks, each predicting whether the true grade exceeds a threshold given that it already exceeded the previous one; the conditional factorisation provides rank-consistent probability estimates without weight sharing or explicit hyperparameters. ORCU (Ordinal Regression loss for Calibration and Unimodality [22]) takes a soft-label approach: the target is a discretised Gaussian centred on the true grade, and training minimises the Kullback–Leibler divergence to this target with an additional unimodality penalty and an optional cross-entropy auxiliary, producing a calibrated unimodal posterior over grades. Since the goal here is to benchmark architectures rather than to propose a new loss, we apply both ORCU and CORN as additional controlled factors across the benchmark, under otherwise identical conditions, to observe whether ordinal-aware training shifts the relative ranking of architectures and how the two formulations differ in practice.
The contribution of this work is twofold. From a methodological standpoint, it illustrates how architecture selection for a medical grading task can be approached as a controlled comparison, which is relevant beyond DR for other medical imaging problems with similar efficiency–accuracy trade-offs (e.g., multimodal cancer prediction [2] and clinical language tasks [23]). From a practical standpoint, it provides evidence on how lightweight models compare to heavier baselines for DR grading in a matched setting. Concretely, the study compares eight architectures spanning 1.3 to 23.5 M parameters under identical training conditions and shared five-fold cross-validation splits, evaluates the effect of two ordinal regression losses (ORCU and CORN) across the benchmark, and reports efficiency metrics (parameters, multiply-adds, on-disk size, and CPU latency) alongside grading accuracy.
The paper proceeds as follows. Section 2 presents the dataset, the preprocessing pipeline, the architectures, the training protocol, the two ordinal regression objectives, and the evaluation metrics. Section 3 gives the architecture and ordinal-loss ablation together with the CPU efficiency analysis. Section 4 comments on the findings and their limitations, and Section 5 draws the main conclusions.

2. Materials and Methods

The experimental setup adopted to compare the eight architectures under matched conditions is presented below, covering the dataset, the offline preprocessing pipeline, the networks and their shared training recipe, the two ordinal regression variants (ORCU and CORN), and the evaluation metrics together with the CPU-based efficiency measurements.

2.1. Dataset

Experiments are carried out on the APTOS 2019 Blindness Detection dataset [12], which comprises 3662 colour fundus photographs annotated along the five levels of the International Clinical Diabetic Retinopathy (ICDR) scale: Grade 0 (No DR, 1805 images, 49.3%), Grade 1 (Mild, 370, 10.1%), Grade 2 (Moderate, 999, 27.3%), Grade 3 (Severe, 193, 5.3%), and Grade 4 (Proliferative, 295, 8.1%). The class distribution is markedly imbalanced: Grade 0 accounts for close to half of the images, whereas Grade 3 makes up only 5.3%.

2.2. Preprocessing

All images undergo an offline preprocessing pipeline to standardise illumination and enhance retinal structures. The field of view is first isolated using a greyscale-threshold mask with morphological cleaning and largest-connected-component selection, and the resulting bounding box is expanded by a small margin, cropped, and zero-padded to a square aspect ratio. Contrast-limited adaptive histogram equalisation (CLAHE) is then applied to the L channel in the CIELAB colour space to enhance vascular detail while limiting noise amplification. Images are resized to 224 × 224 pixels. Representative examples before and after preprocessing are shown in Figure 1. The same pipeline is used for every model, so it does not contribute to the observed differences between architectures.
Figure 1. Sample fundus images for each DR grade (0–4) before (top) and after (bottom) the CLAHE preprocessing pipeline. CLAHE enhances vascular detail and reduces illumination variability across images.

2.3. Architectures

We evaluate eight architectures spanning a range of design paradigms and parameter counts, summarised in Table 1. Six are lightweight backbones (ShuffleNetV2 [7], MobileNetV3-Small and MobileNetV3-Large [6], EfficientNet-B0 [5], GhostNetV2 [8], DeiT-Tiny [9]), covering between 1.3 and 5.5 M parameters, and two are widely used references with larger capacity (DenseNet121 [3], ResNet50 [4]). All eight architectures are applied to the same APTOS 2019 images, under the same preprocessing, the same splits, the same training recipe, and the same evaluation protocol; only the network and, where indicated, the loss/head change between experiments.
Table 1. Architectures evaluated in this study, ordered by parameter count.
All models are initialised with ImageNet-pretrained weights. For the focal cross-entropy (CE) and ORCU variants, the original classification head is replaced with a single fully connected layer mapping to five logits. For the CORN variant, the final layer is replaced with K − 1 = 4 conditional binary logit outputs. The backbone parameter count is essentially identical across loss variants (the head difference is <0.001 M parameters), so inference cost is the same for a given backbone regardless of loss.
The eight backbones reach their parameter budget through different mechanisms. ShuffleNetV2 uses channel splitting with a parameter-free shuffle to restore cross-group information flow [7]. Both MobileNetV3 variants come from platform-aware NAS and combine depthwise-separable convolutions with squeeze-and-excitation attention and hard-swish activations, Large simply being deeper and wider than Small [6]. EfficientNet-B0 stacks MBConv blocks with SE attention and is itself the NAS-derived baseline from which the compound-scaled B1–B7 variants are obtained [5]. GhostNetV2 produces part of its feature maps via cheap “ghost” operations and compensates with a decoupled fully-connected attention branch [8]. DeiT-Tiny drops convolutions entirely in favour of patch-based self-attention, trained with a distillation token supervised by a CNN teacher [9]. DenseNet121 concatenates each layer’s output with all preceding ones within a block, favouring feature reuse [3], while ResNet50 stacks bottleneck ( 1 × 1 – 3 × 3 – 1 × 1 ) residual blocks with identity skip connections [4].

2.4. Training Protocol

To ensure that the comparison reflects architectural and loss differences rather than training-side choices, all models share the same training recipe. The full dataset (3662 images) is divided into five outer folds, stratified by class; within each outer training set, 12.5% is held out as a validation set for early stopping. This proportion was set so that, combined with the 80%/20% outer train/test split induced by the five outer folds, the overall data allocation approximates the standard 70%/10%/20% train/validation/test partition commonly used in supervised deep learning; it yields a validation subset of approximately 366 images per fold, providing a sufficiently large validation set for monitoring QWK during early stopping while leaving the bulk of each outer training set available for gradient updates. Fold indices are fixed across all experiments so that every model is trained and evaluated on exactly the same images.
Training uses the AdamW optimiser with a learning rate of 10 − 4 and weight decay of 10 − 4 . Early stopping monitors validation QWK with a patience of 10 epochs and a maximum of 50 epochs. Mixed-precision training (FP16) is enabled with gradient clipping at norm 1.0. Data augmentation comprises random horizontal flips ( p = 0.5 ), random rotation ( ± 10 ∘ ), and colour jitter (brightness, contrast, and saturation ±0.1), followed by ImageNet normalisation. The batch size is 32. For the focal cross-entropy baseline, class-weighted focal loss [24] with γ = 2.0 is used to address class imbalance. Models were implemented in PyTorch (PyTorch Foundation, San Francisco, CA, USA) and trained on an NVIDIA T4 GPU (NVIDIA Corporation, Santa Clara, CA, USA).

2.5. Ordinal Regression Losses

DR grading is ordinal: the five severity levels form an ordered scale, so focal cross-entropy, which treats a Grade 0/Grade 4 confusion the same as a Grade 0/Grade 1 one, ignores useful structure. We evaluate two recent ordinal regression objectives as additional controlled factors on all eight backbones, applied as drop-in replacements for the classification head and loss while keeping the backbone and training recipe unchanged. CORN [21] reformulates the K-class problem as K − 1 = 4 conditional binary sub-tasks predicting P ( Y > k ∣ Y > k − 1 ) , which yields rank-consistent cumulative probabilities without tunable hyperparameters. Our ORCU-inspired loss, following [22], keeps the softmax head but trains against a discretised Gaussian soft target centred on the true grade, combining a KL divergence term, a unimodality penalty, and a focal cross-entropy auxiliary; we use the hyperparameters σ = 0.5 , λ uni = 0.2 , and β CE = 0.3 , and the auxiliary term uses the same class-weighted focal loss as the CE baseline so that class imbalance is handled identically across all three variants.

2.6. Evaluation Metrics

The primary metric is quadratic weighted kappa (QWK), the standard metric for DR grading, which penalises misclassifications proportionally to the squared distance between predicted and true grades. For K ordered grades, let O ∈ R K × K be the confusion matrix, where O i j is the number of images of true grade i predicted as grade j, and let E be the matrix of expected counts obtained from the outer product of the predicted and true marginals. With quadratic weights w i j = ( i − j ) 2 / ( K − 1 ) 2 , QWK is
κ = 1 − ∑ i , j w i j O i j ∑ i , j w i j E i j ,
where κ = 1 denotes perfect agreement, κ = 0 agreement no better than chance, and κ < 0 systematic disagreement. Because the weights grow quadratically with grade distance, QWK is well suited to the ordinal structure of the ICDR scale. Secondary metrics include accuracy, macro-averaged F1-score (F1-Macro), and mean absolute error (MAE, in grades). All metrics are computed on the held-out test fold and averaged across the five folds.
Inference efficiency is evaluated on a consumer CPU (Intel Core i7, 13th generation, 12 threads; PyTorch 2.8.0 CPU build). Latency at batch size 1 is measured with a synthetic input tensor of size 1 × 3 × 224 × 224 in FP32, using 20 warm-up passes followed by 100 timed passes per model. Throughput is additionally measured at batch size 32. Multiply-add operations (GMACs) are measured via the thop profiler, and the on-disk size (MB) of the saved state dictionary is reported to characterise storage requirements.

3. Results

This section reports the architecture-versus-loss comparison across the eight backbones and three loss variants, followed by the CPU efficiency analysis.

3.1. Architectures and Ordinal Regression Losses

Table 2 compares focal cross-entropy (CE) training against the two ordinal regression objectives, ORCU and CORN, across all eight architectures. Under focal cross-entropy alone, DenseNet121 and ResNet50 lead (0.893 and 0.892 QWK), DeiT-Tiny follows at 0.883 QWK (within one standard deviation of ResNet50 despite a 77% parameter reduction), and the remaining lightweight backbones fall within 0.020 QWK of ResNet50 except MobileNetV3-Small (0.866 QWK).
Table 2. Loss-function ablation comparing focal cross-entropy (CE), ORCU, and CORN under five-fold cross-validation (mean ± std). For each model, the highest QWK and the lowest MAE are highlighted in bold.
When averaged over the eight backbones, mean QWK rises by +0.010 with ORCU and by +0.011 with CORN relative to the focal cross-entropy baseline, and each of the two ordinal losses yields a QWK gain on every backbone tested. The largest gains are observed on the most compact models (ShuffleNetV2: +0.021 QWK under CORN; MobileNetV3-Large: +0.018 QWK under ORCU), while the smallest are on ResNet50 (+0.004 for ORCU, +0.002 for CORN), which already had the strongest CE baseline. Accuracy and F1-Macro follow the QWK trend with smaller absolute differences, and MAE drops under both ordinal losses for seven of the eight backbones. The two losses track closely: ORCU gives a slightly higher mean QWK on five backbones and CORN on three, with an absolute difference of at most 0.007 QWK. MobileNetV3-Large with ORCU (0.891 QWK) reaches a mean QWK within 0.001 of the 23.5 M-parameter ResNet50 baseline (0.892 QWK), with 82% fewer parameters; DenseNet121 with ORCU (0.902 QWK) is the highest QWK observed across all 24 (model, loss) combinations.

3.2. Efficiency Analysis

Table 3 reports deployment efficiency for all eight backbones alongside their best observed QWK across the three loss variants. Latency is measured at batch size 1 on an Intel Core i7 13th-generation CPU (12 threads, PyTorch 2.8.0 CPU build), and throughput at batch size 32. Because the head difference between loss variants changes the parameter count by less than 0.001 M, inference cost is essentially identical across CE/ORCU/CORN for a given backbone; we therefore report one latency per backbone.
Table 3. CPU deployment efficiency for the eight backbones. GMACs are multiply-add operations per forward pass at input resolution 224 × 224 . “Best QWK” is the maximum mean QWK over the three loss variants (CE, ORCU, CORN).
On the CPU used here, MobileNetV3-Large is the fastest backbone at 28.0 ms per image, which is 4.6× faster than ResNet50 (127.8 ms) and 5.2× faster than DenseNet121 (145.2 ms); its on-disk size (16.2 MB) is also 5.5× smaller than that of ResNet50 (90.0 MB), and its best observed QWK (0.891, with ORCU) is within 0.005 of ResNet50’s best (0.896, with ORCU) and within 0.011 of the overall top (DenseNet121 with ORCU, 0.902). ShuffleNetV2 (1.3 M, 40.2 ms) and EfficientNet-B0 (4.0 M, 41.9 ms) are also in the sub-50 ms latency range; MobileNetV3-Small has the lowest GMACs but a higher single-image latency than MobileNetV3-Large, reflecting the overhead of its many small layers, while it remains the highest-throughput model at batch size 32 (140 img/s). GhostNetV2’s CPU latency (85.2 ms) is disproportionate to its GMACs (0.18 G), which we attribute to the memory-access pattern of its ghost modules on CPU. Two configurations stand out for different purposes: MobileNetV3-Large with ORCU for deployment where latency and storage are constrained (0.891 QWK, 28.0 ms, 16.2 MB), and DenseNet121 with ORCU when compute constraints are relaxed (0.902 QWK, 145.2 ms, 27.1 MB).

4. Discussion

The main observation from this benchmark is that, in this setup, the QWK gap between lightweight and larger architectures is smaller than the difference in parameter counts would suggest. Under matched training and evaluation with focal cross-entropy, DeiT-Tiny (5.5 M parameters) is within 0.009 QWK of ResNet50 (23.5 M), and when the ordinal regression objectives are added, MobileNetV3-Large with ORCU (4.2 M parameters, 0.891 QWK) reaches a mean QWK within 0.005 of ResNet50 with its best loss (0.896 QWK). In the context of this dataset and protocol, competitive QWK does not require a large backbone, and smaller models are a reasonable choice when resource constraints apply.
The ORCU and CORN ablation indicates that, for this ordinal task, the choice of loss function has an effect of the same order of magnitude as moving between architectures. Average QWK gains over focal cross-entropy are +0.010 for ORCU and +0.011 for CORN, with the largest single-model improvements (+0.021 for ShuffleNetV2 under CORN, +0.018 for MobileNetV3-Large under ORCU) on the most compact backbones. The two losses track closely on QWK and reach the best mean QWK on roughly equal numbers of backbones; the per-fold direction is consistent in favour of the ordinal losses on every backbone, although with only five folds we read this as a directional trend rather than a formal significance claim.
The CPU efficiency results clarify the deployment cost. On the CPU used here, MobileNetV3-Large processes a fundus image in 28.0 ms (about 36 images/s at batch size 1), 4.6× faster than ResNet50 in these measurements, with 18× fewer GMACs (0.23 vs. 4.13) and a 5.5× smaller on-disk size (16.2 MB vs. 90.0 MB). ShuffleNetV2, EfficientNet-B0, and MobileNetV3-Large form a sub-50 ms latency cluster whose best QWKs span 0.891–0.894, with DeiT-Tiny close behind (0.898 QWK at 58.7 ms). GhostNetV2 stands out as an efficiency outlier: despite one of the lowest GMAC counts in the benchmark (0.18 G), its single-image CPU latency (85.2 ms) is comparable to the heavier DeiT-Tiny, which reflects that its ghost-module feature reuse is harder to accelerate on general-purpose CPU than the depthwise separable convolutions of MobileNetV3.
DeiT-Tiny, a pure vision transformer with 5.5 M parameters, is competitive with CNNs of comparable size in this benchmark, which is in line with recent reports on vision transformers for DR grading [16,17,18]. Both ordinal losses also transfer to this attention-based backbone, with the largest gain coming from CORN (+0.015 QWK) and ORCU close behind (+0.010 QWK), in line with the pattern observed on the CNN backbones.
Limitations. Evaluation is limited to a single dataset (APTOS 2019); generalisability to other populations, cameras, and imaging conditions requires further validation on additional, external datasets. The substantial class imbalance of APTOS 2019—with Grade 0 accounting for nearly half of the images and Grade 3 for only 5.3%—also places an upper bound on minority-class performance. Our CPU latency measurements were obtained on a single consumer-grade laptop; complementary measurements on mobile devices and embedded platforms (such as a Raspberry Pi or smartphone SoCs) would reinforce the deployment discussion.
Perspectives and future work. Several directions follow from this study. First, the matched protocol could be extended to additional public DR datasets (e.g., EyePACS, Messidor-2, IDRiD) and to multi-source training, to assess cross-domain generalisation across cameras, populations, and acquisition conditions. Second, the deployment analysis invites validation on mobile and embedded targets (smartphone SoCs, Raspberry Pi), combined with post-training compression such as quantisation, pruning, and knowledge distillation, which could further reduce the latency and storage footprint of the lightweight backbones. Finally, the loss axis could be broadened to other ordinal and cost-sensitive objectives, paired with a calibration study; clinical-facing extensions such as explainability and referral-oriented evaluation remain a further avenue.

5. Conclusions

For DR grading under a protocol that fixed preprocessing, splits, training recipe, and evaluation across all eight architectures, models with as few as 4–5.5 M parameters reached within 0.011 QWK of the 23.5 M-parameter ResNet50 baseline. Competitive predictive performance therefore does not require the largest available backbone.
Both ORCU and CORN improved QWK over focal cross-entropy for every architecture tested, with the largest gains on the most compact backbones. Loss design narrows part of the gap to larger models, in addition to the effect of architecture choice. ORCU applied to MobileNetV3-Large reached a QWK of 0.891, remaining within 0.001 QWK of the ResNet50 focal-CE baseline (0.892) and within 0.005 of the best ResNet50 configuration (0.896), while requiring only a fraction of the parameter count and inference cost, making it a reasonable choice when latency and storage are constrained. DenseNet121 with ORCU gives the highest QWK observed and remains preferable when this is the priority.
These results support the value of a controlled cross-architecture comparison combined with a shared loss axis for model selection in resource-constrained medical imaging pipelines.

Author Contributions

Conceptualization, Y.C., M.M. and M.R.; methodology, software, investigation and writing—original draft preparation, Y.C.; writing—review and editing, M.M. and M.R.; supervision, M.M. and M.R. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The APTOS 2019 dataset analysed in this study is publicly available at https://www.kaggle.com/c/aptos2019-blindness-detection (accessed on 3 November 2026).

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Nadeem, M.W.; Goh, H.G.; Hussain, M.; Liew, S.-Y.; Andonovic, I.; Khan, M.A. Deep learning for diabetic retinopathy analysis: A review, research challenges, and future directions. Sensors 2022, 22, 6780. [Google Scholar] [CrossRef] [Scilit]
  2. Rhanoui, M.; Mikram, M.; Amazian, K.; Ait-Abderrahim, A.; Yousfi, S.; Toughrai, I. Multimodal machine learning for predicting post-surgery quality of life in colorectal cancer patients. J. Imaging 2024, 10, 297. [Google Scholar] [CrossRef] [Scilit]
  3. Huang, G.; Liu, Z.; Van Der Maaten, L.; Weinberger, K.Q. Densely connected convolutional networks. In Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition (CVPR), Honolulu, HI, USA, 21–26 July 2017; pp. 4700–4708. [Google Scholar]
  4. He, K.; Zhang, X.; Ren, S.; Sun, J. Deep residual learning for image recognition. In Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition (CVPR), Las Vegas, NV, USA, 27–30 June 2016; pp. 770–778. [Google Scholar]
  5. Tan, M.; Le, Q.V. EfficientNet: Rethinking model scaling for convolutional neural networks. In Proceedings of the 36th International Conference on Machine Learning (ICML), Long Beach, CA, USA, 9–15 June 2019; pp. 6105–6114. [Google Scholar]
  6. Howard, A.; Sandler, M.; Chu, G.; Chen, L.-C.; Chen, B.; Tan, M.; Wang, W.; Zhu, Y.; Pang, R.; Vasudevan, V.; et al. Searching for MobileNetV3. In Proceedings of the IEEE/CVF International Conference on Computer Vision (ICCV), Seoul, Republic of Korea, 27 October–2 November 2019; pp. 1314–1324. [Google Scholar]
  7. Ma, N.; Zhang, X.; Zheng, H.-T.; Sun, J. ShuffleNet V2: Practical guidelines for efficient CNN architecture design. In Proceedings of the European Conference on Computer Vision (ECCV), Munich, Germany, 8–14 September 2018; pp. 116–131. [Google Scholar]
  8. Tang, Y.; Han, K.; Guo, J.; Xu, C.; Xu, C.; Wang, Y. GhostNetV2: Enhance cheap operation with long-range attention. In Proceedings of the Advances in Neural Information Processing Systems (NeurIPS), New Orleans, LA, USA, 28 November–9 December 2022. [Google Scholar]
  9. Touvron, H.; Cord, M.; Douze, M.; Massa, F.; Sablayrolles, A.; Jégou, H. Training data-efficient image transformers & distillation through attention. In Proceedings of the 38th International Conference on Machine Learning (ICML), Virtual, 18–24 July 2021; pp. 10347–10357. [Google Scholar]
  10. Owens, D.R.; Gurudas, S.; Sivaprasad, S.; Zaidi, F.; Tapp, R.; Kazantzis, D.; Evans, L.; Thomas, R.L. IDF Diabetes Atlas: A worldwide review of studies utilizing retinal photography to screen for diabetic retinopathy from 2017 to 2024 inclusive. Diabetes Res. Clin. Pract. 2025, 226, 112346. [Google Scholar] [CrossRef] [Scilit]
  11. Wong, T.Y.; Sun, J.; Kawasaki, R.; Ruamviboonsuk, P.; Gupta, N.; Lansingh, V.C.; Maia, M.; Mathenge, W.; Moreker, S.; Muqit, M.M.; et al. Guidelines on diabetic eye care: The International Council of Ophthalmology recommendations for screening, follow-up, referral, and treatment based on resource settings. Ophthalmology 2018, 125, 1608–1622. [Google Scholar]
  12. APTOS 2019 Blindness Detection. Available online: https://www.kaggle.com/c/aptos2019-blindness-detection (accessed on 3 November 2026).
  13. Mikram, M.; Moujahdi, C.; Rhanoui, M.; Meddad, M.; Khallout, A. Hybrid deep learning models for diabetic retinopathy classification. In Big Data and Internet of Things, Lecture Notes in Networks and Systems; Springer: Cham, Switzerland, 2022; Volume 489, pp. 167–178. [Google Scholar]
  14. Dharrao, D.; Dharrao, M.; Patil, S.; Salvin, S.; Ahire, P.; Dongre, Y. AI-driven detection and classification of diabetic retinopathy stages using EfficientNetB0. Discov. Appl. Sci. 2025, 7, 1400. [Google Scholar] [CrossRef] [Scilit]
  15. Akter, Z.; Ahad, J.I.; Farhan, M.M.; Khan, R. Graph-enhanced deep learning for diabetic retinopathy diagnosis: A quality-aware and uncertainty-driven approach. PLoS Comput. Biol. 2025, 21, e1013745. [Google Scholar] [CrossRef] [Scilit]
  16. Liu, C.; Wang, W.; Lian, J.; Jiao, W. Lesion classification and diabetic retinopathy grading by integrating softmax and pooling operators into vision transformer. Front. Public Health 2025, 12, 1442114. [Google Scholar] [CrossRef] [Scilit]
  17. Ahmed, F.; Uddin, M.J. OcuViT: A vision transformer-based approach for automated diabetic retinopathy and AMD classification. J. Imaging Inform. Med. 2026, 39, 2511–2521. [Google Scholar] [CrossRef] [Scilit]
  18. Bhoopalan, R.; Sekar, P.; Nagaprasad, N.; Mamo, T.R.; Krishnaraj, R. Task optimized vision transformer for diabetic retinopathy detection and classification in resource constrained early diagnosis settings. Sci. Rep. 2025, 15, 39047. [Google Scholar] [CrossRef] [Scilit]
  19. Zafar, A.; Kim, K.S.; Ali, M.U.; Byun, J.H.; Kim, S.-H. A lightweight multi-deep learning framework for accurate diabetic retinopathy detection and multi-level severity identification. Front. Med. 2025, 12, 1551315. [Google Scholar] [CrossRef] [Scilit]
  20. Ara, T.; Mishra, V.P.; Bali, M.; Yenkikar, A. Hybrid quantum-classical deep learning framework for balanced multiclass diabetic retinopathy classification. MethodsX 2025, 15, 103605. [Google Scholar] [CrossRef] [Scilit]
  21. Shi, X.; Cao, W.; Raschka, S. Deep neural networks for rank-consistent ordinal regression based on conditional probabilities. Pattern Anal. Appl. 2023, 26, 941–955. [Google Scholar] [CrossRef] [Scilit]
  22. Kim, D.; Chung, H.; Jang, I. Calibration of ordinal regression networks. arXiv 2024, arXiv:2410.15658. [Google Scholar]
  23. Zekaoui, N.E.; Yousfi, S.; Mikram, M.; Rhanoui, M. Enhancing large language models’ utility for medical question-answering: A patient health question summarization approach. In Proceedings of the 14th International Conference on Intelligent Systems: Theories and Applications (SITA), Casablanca, Morocco, 22–23 November 2023. [Google Scholar]
  24. Lin, T.-Y.; Goyal, P.; Girshick, R.; He, K.; Dollár, P. Focal loss for dense object detection. In Proceedings of the IEEE International Conference on Computer Vision (ICCV), Venice, Italy, 22–29 October 2017; pp. 2999–3007. [Google Scholar]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.