Abstract

Automated micromanipulation enables precise, repeatable interaction with single cells and subcellular structures. This review examines four platform archetypes defined by their dominant interaction mechanism: field-mediated optical tweezers, flow-mediated automated microfluidics, mobile microrobots, and fixed-probe micropipette/microneedle systems. Rather than treating them as equivalent robot classes, the review compares their working principles, sensing and control architectures, application fit, quantitative performance evidence, and biological trade-offs. Recent advances in closed-loop operation, intelligent perception, multimodal sensing, and hybrid workflows are analyzed, and a standardized set of reporting metrics is proposed to support objective comparison and translation.

1. Introduction

Robotic cell manipulation has become a cornerstone technology in modern biomedical engineering, enabling precise interaction with individual cells and subcellular structures for applications ranging from basic biological research to regenerative medicine, assisted reproduction, gene editing, and single-cell omics. These applications require the precise positioning, manipulation, and analysis of cells, organelles, droplets, and other microscopic objects with micrometer- or submicrometer-scale accuracy, while maintaining high cell viability and experimental reproducibility. Historically, these tasks depended on expert operators and bespoke instrumentation, which limited throughput and reproducibility. In the last decade, four lines of progress have converged: (i) photonic actuators such as optical tweezers (OTs) that apply calibrated pico- to nano-Newton forces with sub-micrometer resolution; (ii) microfluidic devices that shape flows, droplets, and local environments to sort, merge, lyse, electroporate, or culture; (iii) micro-robotic systems that interface with cells via compliant end-effectors or magnetic tools; and (iv) microneedle-based robotic platforms that execute targeted membrane penetration, microinjection/aspiration, and intracellular probing with force- and vision-guided control (Figure 1). Although these technologies differ substantially in their actuation mechanisms, sensing capabilities, control strategies, and application domains, they share the common objective of enabling accurate, reliable, and increasingly autonomous cell manipulation. Understanding their respective strengths, limitations, and complementarities is therefore essential for guiding future developments in robotic cell manipulation. The unifying thread across these technologies is automation, where sensing, modeling, planning, and feedback control close the loop between observation and action.
Figure 1. Optical tweezers use focused laser beams for non-contact trapping and positioning, while microfluidic platforms employ controlled fluid flow for cell focusing, separation, and sorting. Microrobotic platforms enable guided cell capture and transport, whereas micropipette and microneedle systems support probing, injection, aspiration, and cellular positioning. These technologies are integrated with image acquisition, target detection, trajectory planning, controlled actuation, and real-time feedback to achieve accurate, reproducible, and automated cellular manipulation.
Optical manipulation illustrates both the promise and perils of precision actuation [1]. Holographic OTs can trap and steer tens to hundreds of micro-objects concurrently, enabling rapid alignment, pairing, and force spectroscopy in heterogeneous samples [2]. Focused laser can heat and damage cells, so we must limit how strong the laser is and how long we use it—especially during steps like piercing the membrane or moving [3]. These trade-offs have been formalized via controlling laser intensity, stochastic models of trapping dynamics, and singular-perturbation control to jointly manage rotational and translational manipulation under noise [4,5,6]. Automated routines have demonstrated “cell-surgery” sequences—capture, orientation, perforation, and targeted delivery—that reduce preparation time and variability relative to manual operation [7].
Microfluidic platforms complement photonic tools by embedding upstream and downstream steps on-chip, thereby reducing off-chip transfers that degrade viability and introduce contamination. Pressure-driven networks provide predictable hydrodynamics and permit deterministic focusing, trapping, and release through geometry and valve timing. Droplet microfluidics discretizes operations into addressable pico- to nanoliter volumes, supporting programmable protocols for encapsulation, merging, incubation, and sorting at high throughput [8,9]. Critically, these systems now incorporate sensing—phase/fluorescence imaging, impedance/capacitance readouts and controllers that enable closed-loop responses such as on-the-fly droplet routing or exposure-limited electroporation [8,10,11,12]. Microfluidic–robotic hybrids further bridge scales: robotic micro-hands or magnetic micro-tools interface with cells within microchannels to perform tasks (e.g., organelle positioning, mechanotransduction assays) that benefit from both stable flow control and dexterous contact [13,14].
Microneedle-based robotic micromanipulation provides direct mechanical access to the cell interior and membrane, enabling operations that are difficult to realize with purely contactless or flow-based methods. Robotic microinjection and aspiration systems combine high-NA imaging with force/impedance sensing to detect membrane contact, infer penetration events, and meter injection volumes with sub-picoliter precision [15,16,17]. Closed-loop visual servoing localizes needle tips against low-contrast backgrounds and compensates for stage drift and sample motion, supporting subcellular targeting of nuclei, nucleoli, and specific organelles [18,19]. These capabilities enable intracellular delivery (e.g., CRISPR/Cas complexes, mRNA, organelles), patch-clamp-style electrophysiology, and minimally invasive biopsy/sampling for downstream omics analyses, while maintaining high post-procedure viability when force and dose constraints are enforced [20]. For microneedle systems, additional metrics such as penetration success rate, membrane integrity, injection volume, injection rate, and tip size optimization are critical for fair evaluation.
Although significant progress has been made in robotic cell manipulation, existing review articles typically focus on individual technologies, such as optical tweezers, microfluidics, or robotic microinjection, without providing a comprehensive comparison of their sensing modalities, control strategies, application domains, and technological trade-offs. Moreover, recent advances in artificial intelligence, multimodal sensing, hybrid robotic platforms, and autonomous operation have begun to blur the boundaries between these technologies, creating new opportunities for integrated robotic cell manipulation systems. A comprehensive synthesis of these developments is therefore timely and necessary.
Unlike previous reviews that primarily summarize individual manipulation techniques, this review provides a comparative analysis of four major automated single-cell manipulation paradigms optical tweezers, microfluidic platforms, microrobots, and micropipette/microneedle systems. Beyond comparing their actuation principles, sensing modalities, control strategies, strengths, limitations, and application domains, we critically analyze representative hybrid systems at three levels of integration: physical coupling of manipulation mechanisms, shared sensing and control, and workflow-level coordination. For each level, we examine the function of the combined components, the resulting performance benefit, the additional integration burden, and the end-to-end metrics required for objective evaluation. We further discuss artificial intelligence, multimodal sensing, standardization, reproducibility, and clinical translation.
The remainder of this manuscript is organized as follows. We present an in-depth literature review structured around four technology strands: (i) Optical-Tweezer (OT)-based robotic micromanipulation, (ii) automated microfluidic devices for cell manipulation, (iii) automated microrobots for cell manipulation, and (iv) automated micropipette-based micromanipulation. For each section, we present system architectures, actuation and sensing modalities, control and planning strategies, and representative applications, and we critically assess current limitations. We then outline future research directions for each area and conclude with a discussion that compares these approaches and highlights open challenges and opportunities.

2. Platform-Specific Working Principles and Recent Advances

2.1. Optical-Tweezer-Based Automated Micromanipulation

Optical tweezers use a highly focused laser beam to trap and move microscopic objects without physical contact. When the laser passes through a cell or particle, refraction produces a gradient force that pulls it toward the region of highest light intensity—the beam focus. This restoring force counteracts the forward scattering force, creating a stable three-dimensional optical trap. By steering the laser focus with a computer-controlled system, cells and organelles can be automatically identified, transported, positioned, and sorted with high precision. Figure 2 and Figure 3 illustrate the working principle and closed-loop automation workflow, respectively, of optical-tweezer-based cell and organelle manipulation.
Figure 2. (A) Working principle. (B) Application of an automated optical-tweezer system.
Figure 3. Automated optical-tweezer manipulation of cells and intracellular organelles. (A) Microscopic images of cells are acquired. (B) Computer vision algorithms detect the target cell or organelle and determine the desired manipulation trajectory. (C) A focused laser beam forms a non-contact optical trap for the controlled positioning of whole cells or selected intracellular organelles. Real-time visual feedback enables continuous monitoring and automated correction of the manipulation process.
Optical tweezers -based automated micromanipulation employs tightly focused laser beams combined with advanced imaging, computer vision, and feedback control mechanisms to precisely position, orient, and manipulate single cells and subcellular structures with sub-micron accuracy. Contemporary OTs systems extensively utilize holographic beam shaping techniques for simultaneous multi-trap generation, enhancing throughput through automated task-level planning and exposure regulation to maintain cellular viability in the presence of Brownian motion and optical heating. To expand functionality, OTs are frequently integrated with auxiliary microtools, microfluidic environments, and supplementary force fields such as dielectrophoresis, thus enabling a diverse range of operations from gentle cell transport and controlled cell pairing to orientation-specific surgical interventions and intracellular material delivery, all while carefully balancing precision, speed, and photodamage. Compared with other robotic cell manipulation technologies, optical tweezers remain the preferred solution for applications requiring non-contact manipulation with submicrometer positioning accuracy. However, their practical deployment continues to require careful balancing of precision, throughput, and photothermal safety, motivating continuous developments in intelligent control and hybrid manipulation strategies.
Fully automated holographic OTs platforms enable cell identification, selection, and fusion without human intervention, relying on integrated vision systems and planning algorithms to ensure accurate positioning and reproducibility with minimal operator involvement [6,21,22,23]. Real-time computational image processing integrated with computer-controlled OTs setups quantifies the mechanical properties of red blood cells, providing standardized biomechanical assays that match expert measurements while significantly enhancing throughput and reproducibility [24]. Unified control frameworks have been developed to perform simultaneous translation and rotation, achieving precise, orientation-specific cell placement, substantially outperforming manual techniques in terms of alignment precision and preparation time [5].
In-depth analyses of stochastic dynamics involved in optical trapping have led to the derivation of operational “safe-speed” boundaries, designed to preserve desired trapping probabilities under dynamic conditions [25]. Saturation-based control strategies manage cell-trap offset distances during multi-target transport, stabilizing cell capture and minimizing unwanted oscillations in crowded environments [26]. Singular perturbation approaches separate rapid optical trap dynamics from slower cellular motions, yielding robust control schemes with improved stability margins, reduced computational load, and simplified integration into higher-level control architectures [27].
Furthermore, holographic OTs systems have successfully demonstrated simultaneous transport of various cell types by maintaining predefined trap-offset constraints, thus enabling generalized, multi-objective manipulations without frequent recalibrations [5,6,7]. Throughput-focused engineering methodologies, combining path planning, automated particle quality control, and hybrid actuator modalities, have facilitated the rapid reconfiguration and assembly of large-scale trap arrays capable of manipulating up to approximately 100 microspheres with improved reliability.
To address inherent phototoxicity and thermal stress from direct laser exposure, indirect manipulation techniques using nano-fabricated, V-shaped microtools controlled via holographic traps have been developed, significantly reducing cellular photodamage without compromising precision [22,28]. Orientation-based cellular surgery has advanced through robust three-dimensional pose estimation methods derived from two-dimensional images, employing T-matrix formulations to achieve precise rotational control required for intricate operations such as nucleus extraction [4]. Non-contact robotic manipulation using negative dielectrophoresis has complemented optical techniques by enabling gentle embryo grasping and rotation, thus reducing mechanical stress and enhancing alignment speed during assisted reproduction procedures [29].
Recent innovations include automated OT-assisted mitochondrial transfers from fetal to adult mesenchymal stem cells, delivering mitochondria with controlled quantity and quality, thereby enhancing recipient cell mitochondrial functionality and gene expression profiles associated with anti-aging pathways [3]. Laser-particle activated cell sorting (L-PACS), which utilizes optically embedded barcodes and spectrometric detection, efficiently organizes manipulated cells downstream, integrating seamlessly with OTs operations [30]. Massively parallel single-cell patterning techniques, employing PDMS micropillar stamps and titanium micro-dishes responsive to near-infrared light for cargo release, provide high-throughput, optically triggered alternatives complementing precise OTs operations [1]. Novel fluorescent lighting techniques combined with dynamic fluorescence imaging and advanced control strategies, such as adaptive sliding-mode controllers, offer improved accuracy and reduced operator effort for complex in vivo manipulations involving fluorescence-guided cell targeting [31]. Recent research has further extended robotic optical tweezers from independent single-cell manipulation toward coordinated multi-cell manipulation through synchronization-based control strategies. By incorporating synchronization theory into robotic optical manipulation, these approaches enable dynamic cell patterning while maintaining prescribed geometric and shape constraints among multiple cells, thereby improving coordination accuracy and scalability during collective manipulation. Such developments represent an important step toward high-throughput optical micromanipulation and demonstrate the potential of integrating advanced control theory with holographic optical tweezers for complex multicellular assembly and tissue engineering applications [32,33].
Overall, recent developments demonstrate that OT-based robotic micromanipulation has evolved from manual single-cell manipulation toward increasingly autonomous platforms integrating computer vision, closed-loop control, holographic beam shaping, and intelligent planning. This evolution has significantly improved manipulation precision, repeatability, and task complexity. Nevertheless, achieving a balance between precision, throughput, and photothermal safety remains a fundamental challenge, motivating continued research into hybrid manipulation strategies and intelligent control frameworks.

2.1.1. Limitations

Several critical limitations persist in OT-based robotic micromanipulation. First, direct optical trapping inevitably introduces photodamage and thermal effects near the focal point, and while indirect manipulation using microtools can mitigate these effects, it does not completely eliminate the associated risks. Second, stochastic disturbances caused by Brownian motion and microfluidic flows frequently lead to particle escape, necessitating conservative control strategies with defined “safe-speed” limits that reduce throughput and maneuverability [25,34,35]. Third, scaling manipulation processes to accommodate multiple simultaneous targets remains constrained by limited camera fields of view, latency in tracking, and calibration drift. Despite advancements in automated planning and quality control, large-scale assemblies remain susceptible to intermittent supervision failures [1,21]. Lastly, achieving accurate three-dimensional perception and reliable in vivo visualization remains challenging. Errors associated with deriving reliable 3D poses from 2D images, combined with tissue-induced optical scattering, significantly degrade image contrast and impose additional modeling complexities that require extensive, specimen-specific calibration [31].

2.1.2. Future Research Directions

Future research should prioritize several key areas to enhance OT-based robotic micromanipulation. These include incorporating laser intensity-aware trajectory planning and control strategies that explicitly account for photothermal exposure limits and stochastic safety constraints, effectively utilizing indirect manipulation techniques to minimize potential cellular damage. Additionally, further advancements in three-dimensional perception and control methods, integrating rigorous optical image-formation models with machine learning-based priors, will enable robust pose estimation even in low signal-to-noise ratio scenarios. Scalable, fault-tolerant multi-object manipulation platforms utilizing predictive tracking algorithms, multi-camera integration, and hierarchical task assignments will also be essential to reliably manipulate hundreds of individual targets simultaneously. Lastly, developing gentler and more standardized in vivo manipulation techniques that integrate adaptive illumination control with complementary actuation methods—such as negative dielectrophoresis (nDEP) and robotic microhands—alongside rigorous viability assessment, will facilitate the translation of OT-based manipulation techniques from controlled laboratory environments to practical clinical applications. Beyond improvements in optical hardware, future robotic optical tweezers are expected to benefit from artificial intelligence for adaptive trajectory planning, automated parameter optimization, and autonomous decision-making during complex manipulation tasks. Furthermore, synchronization-based multi-cell control and hybrid optical manipulation platforms integrating complementary actuation modalities are expected to improve scalability while reducing photothermal exposure. These developments will facilitate increasingly autonomous and high-throughput optical manipulation systems suitable for complex biological studies and translational biomedical applications.

2.2. Automated Microfluidic Platforms for Cell Manipulation

Microfluidic devices manipulate cells by precisely controlling very small fluid volumes within microscale channels. Because fluid flow is typically laminar, cells can be focused, separated, trapped, transported, or sorted using channel geometry, pressure-driven flow, microvalves, or external forces. Integrated sensors and automated controllers can identify target cells and adjust the flow conditions in real time for accurate cell positioning and collection. Figure 4 and Figure 5 illustrate the working principle and automated workflow, respectively, of a microfluidic platform for cell manipulation.
Figure 4. Working principle of an automated microfluidic platform for cell manipulation. (A) A suspension containing target and non-target cells is introduced through the sample inlet. (B) Sheath flows hydrodynamically focus the cells into a single-file stream. (C) Individual cells are detected and the target cell is identified. (D) Automated actuation of a microvalve or controlled pressure field redirects the target cell toward the collection outlet, while non-target cells proceed to the waste outlet.
Figure 5. Closed-loop automation workflow for microfluidic cell manipulation. (A) A cell suspension is introduced into the microfluidic device. (B) A microscope and camera continuously acquire images of cells flowing through the channel. (C) Computer vision algorithms detect the target cell and determine the required manipulation action. (D) The controller adjusts the pumps and microvalves according to the detection results. (E) The selected cell is directed toward the collection outlet, while the remaining cells are transported to waste. Real-time feedback enables continuous monitoring and correction of the manipulation process.
Existing system architectures include continuous-flow microfluidic chips driven by pressure gradients, incorporating passive and active structures for cell capture and sorting; droplet-based and digital microfluidics that compartmentalize cellular processes into discrete, addressable pico to nanoliter volumes; and open-channel microfluidics optimized for seamless integration with macro-scale robotic interfaces. Automation technologies ranging from precise valve sequencing and electrode manipulation to machine vision feedback and data-driven control algorithms transform these microfluidic systems into versatile micro-robots, capable of reliable capture, transport, stimulation, lysis, cryopreservation, and culture at high reproducibility and scale. Representative examples encompass pressure-driven single-cell handling devices [11], droplet–digital microfluidic platforms for programmable encapsulation and sorting, high-throughput inertial/vortex-based sorting methods [36,37], hybrid robotic–microfluidic platforms tailored for embryo and oocyte manipulation [38,39], and intelligent digital microfluidic (DMF) systems integrating object detection and large language models (LLMs) for adaptive electrode control [40].
Pressure-driven microchannels offer controlled hydrodynamics, enabling gentle and deterministic single-cell manipulation. Shen et al. developed an automated microfluidic platform utilizing tailored channel geometries and pressure-driven flows to perform selective single-cell capture, isolation, and release, demonstrating precise on-chip manipulation without bulky external actuators [11]. For high-throughput applications, inertial and vortex-driven sorters utilize fluid dynamics to achieve exceptional sorting rates with phenotype-based discrimination. Zhukov et al. designed a highly parallelized vortex-driven sorter, significantly enhancing throughput while maintaining reliable phenotype-specific cell routing [36]. Specific microstructures, such as interdigital (serpentine/side-branch) channels [37], double-slit arrays [41], and micropillar arrays [42], improve single-cell capture efficiency and cell viability, enabling programmable trapping, efficient cell isolation, and stable on-chip culture. Continuous-flow platforms also facilitate dynamic microenvironment control, as demonstrated by Song et al., who modulated spatial-temporal stimuli for cells to derive closed-loop manipulation strategies [43].
Droplet microfluidics compartmentalizes cellular assays into uniform microdroplets, enhancing encapsulation, incubation, and sorting capabilities. Ahmadi et al. combined droplet generation with an electrowetting-on-dielectric (EWOD)-based DMF system, achieving programmable, on-demand droplet manipulation within a unified platform, minimizing transfer-induced losses [39]. Tang et al. addressed challenges in single-cell encapsulation rates through fine-tunable on-chip enrichment, significantly increasing single-cell occupancy while preserving viability [9]. Jia et al. further advanced control methodologies by introducing an intelligent active-matrix DMF system employing object detection coupled with LLM-based electrode actuation planning, improving robustness and protocol generalization [40].
Hybrid robotic–microfluidic systems bridge micro-scale accuracy and macro-scale automation. Automated robotic platforms integrated with microfluidics streamline critical reproductive workflows, standardizing operations such as embryo vitrification, media exchange, and thermal management [44]. The same authors subsequently developed a complementary open microfluidic platform compatible with standardized carriers (e.g., Cryotop), facilitating precise control of vitrification parameters while simplifying system integration [45]. Liang et al. developed a robotic manipulator integrated directly with a microfluidic chip to automate repetitive, operator-dependent loading and reloading tasks in oocyte processing [46]. Vision-guided fluid control mechanisms have also improved reproducibility in cryopreservation by enabling precise positioning within gradients and timing of exposure steps [12]. Integration of real-time perception systems enhances the robustness of micromanipulation, accommodating variability among cells and device conditions. High-throughput analysis methods developed by Choi et al. demonstrated automated cell segmentation and tracking, allowing robust quantification of cellular properties for decision-making in real-time control scenarios [10]. Embedded microfluidic modules reduce off-chip transfers and enhance reproducibility. Huang et al. introduced optically triggered lysis within microfluidic platforms, automating subcellular processing and preparation for downstream analysis [47].

2.2.1. Limitations

Despite significant progress, several challenges persist in microfluidic micromanipulation. Passive continuous-flow systems struggle with deterministic single-cell release, requiring active geometries or precise flow control [11,41,42]. Inertial and vortex sorters offer high throughput but trade off fine per-cell control and are sensitive to fluid properties [36,37]. Channel fouling, bubble formation, and geometry-specific tuning hinder long-term operation, while pressure-based systems raise integration and cost barriers. In droplet microfluidics, Poisson-based loading leads to inefficiencies unless active enrichment is applied [9,39]. Surfactant formulations may affect biocompatibility and downstream assays. Digital microfluidics (DMF) faces constraints from dielectric breakdown, evaporation, and electrode failures, and intelligent control systems require significant computational resources while being sensitive to environmental changes [40]. Reproductive workflows demand tight control over timing, osmolarity, and thermal transitions. Standardized carriers like Cryotop simplify use but restrict flexibility [44,45]. Vision-in-the-loop systems depend on stable imaging and may suffer from latency or generalization issues [10,12,40]. On-chip processing methods like optically induced lysis risk local heating and add system complexity [47]. Long-term culture is challenged by clogging, waste accumulation, and integration with downstream omics.

2.2.2. Future Directions

Future work should focus on modular, interoperable systems that integrate continuous-flow, DMF, and droplet operations. Control strategies should combine real-time vision with learning-based, adaptive policies for dynamic tasks. Device self-diagnostics and deterministic cell loading will improve robustness and efficiency. Next-gen sorters should merge inertial flows with per-cell sensing and include standardized post-sort metrics. Materials and surface treatments must address fouling and evaporation, enabling long-term, unattended use. Reproductive applications require validated, auditable systems that meet clinical standards. Stronger integration of subcellular processing with omics pipelines and longitudinal culture platforms will support advanced single-cell studies. Recent microfluidic technologies are also being applied to cell manufacturing, where precise fluidic control can improve scalability, process integration, and the predictability of cell-based therapies [48].

2.3. Microrobotic Platforms for Cell Manipulation

Microrobots have emerged as versatile platforms for high-precision, minimally invasive manipulation of single cells and subcellular components. Microrobotic platforms use microscale mobile devices to capture, transport, position, or release individual cells within a controlled fluid environment. The microrobots are commonly actuated by external magnetic fields, which generate force and torque for directional movement without requiring onboard power. By adjusting the field, the microrobot can navigate toward a target cell, mechanically capture or support it, transport it along a planned path, and release it at the desired location. Imaging and feedback control can further improve the precision and automation of this process. Figure 6 and Figure 7 illustrate the working principle and closed-loop automation workflow, respectively, of a magnetically actuated microrobotic platform for cell manipulation. Compared to conventional techniques such as microinjection or optical tweezers, microrobotic systems offer distinct advantages by integrating both contact and non-contact manipulation modalities, enabling autonomous navigation within microfluidic environments, and supporting closed-loop execution of complex task sequences. Recent developments have introduced hybrid actuation mechanisms tailored for delicate biological interactions, real-time visual perception algorithms for tracking optically transparent microrobots, high-resolution actuation strategies for assisted reproductive workflows, formal control architectures for coordinated multi-agent manipulation, and soft, compliant end-effectors capable of grasping and transporting fragile biological samples [49,50]. Collectively, these advancements are steering the field from manual, operator-dependent platforms toward semi- and fully autonomous systems equipped with intelligent control, robust sensing, and application-specific design frameworks. Recent optically actuated soft microrobotic tools have demonstrated gentle cell transportation, manipulation, and cell-to-cell interactions, highlighting the potential of compliant mobile platforms for delicate biological tasks [51].
Figure 6. Working principle of a magnetically actuated microrobotic platform for cell manipulation. (A) External electromagnetic coils generate a controllable magnetic field that produces force and torque on the microrobot. (B) The microrobot is guided toward the selected target cell along a predefined path. (C) The target cell is captured by the microrobot. (D) The captured cell is transported to the desired location and released through controlled magnetic actuation.
Figure 7. Closed-loop automation workflow for microrobotic cell manipulation. (A) A microscope and camera acquire images of the microrobot and cells within the manipulation chamber. (B) Computer vision algorithms detect and track the microrobot and target cell. (C) A collision-free trajectory is planned toward the desired target position. (D) The controller regulates the electromagnetic coils to generate the required magnetic field for microrobot actuation. (E) The microrobot captures and positions the target cell, while real-time visual feedback continuously updates and corrects its motion.
Among various actuation strategies, magnetic actuation has maintained dominance due to its compatibility with biological media, deep penetration capabilities, and ability to exert controlled forces and torques at small scales [52]. Model predictive control (MPC) has been implemented to ensure robust trajectory tracking of magnetically actuated microrollers while accounting for environmental constraints and surface-induced disturbances [53]. Multi-physics actuation strategies further extend the manipulation repertoire. For instance, magneto-acoustic propulsion systems, augmented with real-time feedback control, improve microrobot stability during alignment and approach phases, whereas the combination of ultrasonic levitation and magnetic control has been employed to achieve precise, non-contact three-dimensional orientation of oocytes while minimizing mechanical stress on the cells [54]. These hybrid strategies facilitate non-contact stabilization, alignment, and orientation prior to physical interaction, which is critical for ensuring repeatable, safe manipulation in sensitive biological environments.
The mechanical interface between microrobot and target cell plays a pivotal role in safeguarding cell integrity during interaction. Recent advances in soft-bodied magnetic microrobots equipped with compliant grippers have demonstrated improved conformability and reduced stress concentrations during cell capture, transport, and release compared to their rigid counterparts [55].
Achieving autonomy at the microscale requires reliable perception, particularly given the transparency of many microrobots and the refractive complexity of biological environments. To this end, advanced computer vision techniques have been developed for real-time, three-dimensional pose estimation of microrobots under low-contrast imaging conditions [56]. In addition to spatial tracking, force-sensitive feedback is vital for regulating contact forces during manipulation. Microrobots embedded with micro-Newton-scale force sensors have enabled automated operations with minimized overshoot and improved consistency on compliant biological substrates [57]. Together, precise localization and force sensing provide the critical observability needed for dexterous, autonomous manipulation tasks.
On the control front, advanced planning and feedback algorithms have been formulated to ensure safe and precise microrobot behavior. System-level coordination among multiple microrobots has been achieved through formal methods such as temporal logic-based task planning, allowing the assignment and execution of complex task sequences under timing constraints [50]. Meanwhile, human–robot interaction paradigms have been explored to facilitate intuitive operation; haptic teleoperation systems incorporating force feedback have shown promise in guiding user input toward safer trajectories, particularly in magnetically actuated scenarios [58].
These technological advances have enabled a range of bio-relevant applications. In assisted reproduction, ultrasonic levitation paired with magnetic steering has allowed for accurate, non-contact three-dimensional oocyte rotation to facilitate visual inspection and alignment [56,59]. For intracellular delivery, on-chip nanorobots equipped with functionalized needle-like tips have demonstrated the ability to puncture cell membranes with high precision and minimal collateral damage, enabling targeted injection or cytoplasmic sampling [60]. In cell sorting and transport, soft magnetic microrobots have been shown to pick up, carry, and gently release individual cells with reduced contact-induced stress [55]. In tissue engineering and high-throughput biological assays, microfabricated chip-level features such as V-groove arrays, coupled with rapid magnetic actuation, have enabled fast and repeatable positioning and patterning of cells [14]. These application domains are supported by increasingly robust tracking and feedback systems, including transparent-robot localization algorithms and microforce-aware controllers.

2.3.1. Limitations

Despite these advancements, several limitations persist. In optically scattering or acoustically attenuating media, pose estimation and force feedback quality degrade due to reduced imaging contrast and signal scattering, compromising the reliability of visual and acoustic feedback mechanisms [54]. Magnetic actuation using global fields introduces coupling effects between adjacent microrobots or with nearby ferromagnetic structures, limiting independent control and increasing the complexity of motion scheduling and collision avoidance [50]. While microfabricated guidance structures such as V-grooves enhance throughput and repeatability, they inherently limit system generalizability to predefined geometries and are less effective in unstructured environments [14].
Soft grippers, though beneficial for compliant manipulation, can exhibit reduced positional accuracy and temporal drift. Similarly, nanoneedle tools may cause inconsistent membrane damage due to variability in cell stiffness and shape [55]. Many microrobotic platforms remain specialized and lack the modularity required for mid-workflow tool switching. Furthermore, vision systems typically rely on transparent media and high-numerical-aperture objectives, and often suffer from limited depth tracking, occlusion handling, and sensitivity to lighting artifacts. Force sensors, while improving in resolution, still face challenges such as drift and limited spatial range, and sensor fusion remains underdeveloped [57].
Control strategies like MPC demand accurate real-time models and state estimation; deviations due to fluidic interactions or biological heterogeneity can reduce control performance [53]. Haptic teleoperation, while effective in low-throughput settings, does not scale efficiently to multi-agent scenarios and depends on reliable, low-latency feedback for safe operation [58]. Moreover, most demonstrations remain confined to in vitro environments with controlled optics and carefully selected media. The long-term biocompatibility of repeated magnetic or acoustic exposure, particularly in dynamic or semi-physiological settings, remains insufficiently studied [54,55].

2.3.2. Future Directions

Looking forward, achieving robust, automated microrobotic cell manipulation will require integrated co-design of multi-modal actuation and perception systems. By systematically combining magnetic, acoustic, and hydrodynamic field modalities, it is possible to expand the safe operational envelope and achieve stable alignment in biologically relevant media, while minimizing bio-exposure risks. On the control side, hybrid learning-based algorithms built atop model-predictive and formal temporal-logic frameworks offer the potential for real-time adaptation to biological variability and environmental uncertainties without sacrificing safety guarantees. Recent advances in biohybrid microrobots, which integrate living biological components with engineered robotic systems, further highlight the potential for improving biocompatibility, adaptive navigation, and targeted therapeutic functions in future robotic cell manipulation platforms [61].
Equally critical will be the development of self-sensing microrobots that incorporate embedded force, proximity, and pose estimation to reduce reliance on external instrumentation, minimize feedback latency, and enhance contact event detection and regulation. Advances in task-specific end-effector engineering, including reconfigurable soft grippers and chemically functionalized probes for selective adhesion or penetration, are expected to expand the applicability of microrobots across diverse cell types and experimental protocols, while preserving viability and throughput.
To accelerate translational progress and improve reproducibility across laboratories, the field would benefit from standardized benchmarks and shared datasets covering imaging conditions, cell types, and canonical micromanipulation tasks such as approach, alignment, grasping, and injection. Complementary to these efforts, open-source chip-level fixtures (e.g., V-groove arrays) and protocol-driven multi-robot evaluation frameworks will be essential for characterizing task allocation, parallel execution, and error recovery under realistic operational constraints. Finally, transitioning from idealized in vitro setups to more complex systems such as organ-on-chip and ex vivo tissues will help to validate sensing, control, and actuation strategies under conditions that approximate future in vivo applications, and clarify the operational boundaries and reliability metrics required for clinical translation.

2.4. Automated Micropipette/Microneedle Manipulation

Automated micropipette and microneedle platforms manipulate cells through precisely controlled positioning and interaction between a microscale tool and a selected cellular target. Cells may be cultured or adhered in a Petri dish, confined within a microfluidic device, or optionally stabilized using an auxiliary holding tool. Depending on the pipette geometry and the intended application, the system can perform material injection or aspiration, mechanical probing, cell deformation, positioning, transfer, or isolation. Motorized micromanipulators, pressure or force controllers, and image-based feedback enable these operations to be performed accurately and repeatedly. Figure 8 and Figure 9 illustrate the generalized working principle and closed-loop automation workflow, respectively, of micropipette- and microneedle-based cell manipulation.
Figure 8. Generalized working principle of micropipette- and microneedle-based cell manipulation. (A) Target cells may be presented in a Petri dish, confined within a microfluidic structure, or optionally stabilized using an auxiliary holding tool. (B) The micropipette or microneedle is aligned with the selected cellular region. (C) Depending on the application, controlled tool–cell interaction may be used for injection or aspiration, mechanical probing, deformation, positioning, or transfer. (D) The tool is withdrawn after manipulation, and the cellular response or manipulation outcome is subsequently verified.
Figure 9. Closed-loop automation workflow for micropipette- and microneedle-based cell manipulation. (A) Microscopic images of the cell and manipulation tool are acquired within the experimental environment. (B) Computer vision algorithms detect the cell, relevant target region, tool tip, and surrounding boundaries. (C) The required manipulation task is selected, and a safe tool trajectory is planned. (D) A controller regulates the micromanipulator together with the required pressure- and force-control parameters. (E) The selected operation such as injection, aspiration, mechanical probing, positioning, or transfer is performed and verified through imaging. Real-time feedback continuously updates the tool trajectory and operating parameters.
Automated micropipette-based micromanipulation integrates high-precision mechatronics, real-time computer vision, and advanced control either model-based or learning-driven to execute delicate cellular procedures such as microinjection, intracytoplasmic sperm injection (ICSI), somatic cell nuclear transfer (SCNT), enucleation, biopsy, and controlled cell orientation or transport. The field has progressed from semi-manual and teleoperated systems to fully automated platforms capable of translating complex biological protocols into consistent, auditable routines across both adherent and suspension cell types, including gametes [62,63,64,65,66,67,68,69]. Recent nanopipette-based nanoinjection platforms have further demonstrated controlled delivery of DNA, proteins, and protein fibrils into living cells at single-molecule resolution, illustrating the expanding role of nanoscale probes in intracellular manipulation [70].
Modern systems combine piezoelectric actuators with specialized micropipette end-effectors to achieve sub-micron resolution, high-frequency axial motion, and programmable rotational degrees of freedom. Innovations include piezo-driven manipulators for adjustable penetration force, drilling mechanisms for controlled ICSI penetration [71], and auto-alignment modules for accurate pipette-to-cell registration [72]. While haptic teleoperation remains useful for expert-guided cases and generating training data [73], recent advances in impedance-controlled microrobotics illustrate how combining axial and rotational motion can minimize trauma during insertion [74].
Automation depends critically on perception. Real-time detection and tracking of cells enable automatic orientation, target following, and precise pipette positioning [75]. 3D morphology estimation informs puncture planning and aspiration parameters [17]. Deep learning-enhanced systems now combine global scene understanding with local refinement for accurate injection-site targeting and throughput optimization [76]. Micropipette control demands accurate interaction modeling. Controllers grounded in fluid–structure interaction models regulate aspiration pressure and velocity, mitigating risks such as lysis or slippage [77]. Handling deformable or motile targets requires shape-aware models, as seen in orientation control of flexible cells [78] and sperm immobilization strategies for downstream ICSI [79].

2.4.1. Limitations

Key limitations persist across hardware, perception, and control. Piezoelectric components are sensitive to temperature and mechanical drift; rotational add-ons introduce inertia and sensing challenges [75]. Many platforms are rigidly tied to specific microscope configurations, limiting portability. Visual perception struggles with low-contrast transparent cells, debris occlusion, and cross-system variability; deep learning models require extensive training data and add latency that can burden real-time control [76,77,79].
Interaction models are affected by biological variability and hardware-induced noise; mid-task dynamics can shift due to clogging or leakage. Parameter tuning can interrupt workflows, and purely model-based approaches struggle with outliers like unusually stiff cells [77,78]. From a translational perspective, large-scale validation, traceability, and ergonomic integration remain underdeveloped. Automation frameworks often lack robust scheduling, error recovery, and traceable sample tracking for long-duration experiments [79]. Additionally, the field lacks standardized benchmarks and cross-lab reproducibility studies; many foundational works assume idealized conditions and do not account for integration complexity [74].

2.4.2. Future Directions

The future of micropipette-based automation lies in combining interpretable physics models with adaptive learning systems that self-calibrate to variations in cells, pipettes, and imaging setups. Multimodal sensing—including visual, pressure, impedance, and tip-mounted force feedback—can expand observability for vision-limited or occlusion-prone tasks. Software orchestration via modular task graphs should integrate perception, motion, and quality control, with automatic retries and contamination safeguards. Open datasets reflecting real-world variation across optics, cell lines, and procedures will be critical for generalization. Hardware trends will favor compact actuators with integrated sensing and damping, and rotational–axial coupling to minimize insertion trauma. Clinical translation will depend on rigorous, multi-center validation of outcomes, audit trails, and ergonomic design to ensure systems integrate smoothly into embryology and cellular engineering workflows.

3. Discussion

Table 1 summarizes the key robotic cell manipulation techniques discussed in this review. Each approach offers distinct advantages and is suited for specific tasks, environments, or biological contexts. Optical tweezers provide highly precise, non-contact manipulation but suffer from phototoxicity and limited scalability. Microfluidic platforms excel in throughput and integration but are often constrained in terms of flexibility. Microrobots offer a balance of contact/non-contact manipulation in complex environments, although they face control and perception challenges. Finally, micropipette and microneedle systems provide direct intracellular access with fine control but require sophisticated perception and force regulation strategies. This comparison underscores the need for hybrid platforms that combine the strengths of these approaches while mitigating their individual limitations.
Table 1. Summary comparison of robotic cell manipulation approaches.

3.1. Application-Dependent Trade-Offs Among Automated Cell Manipulation Platforms

No platform simultaneously maximizes precision, throughput, flexibility, intracellular access, and biological safety. Optical tweezers are well suited to delicate non-contact positioning but remain constrained by working volume, exposure, and scaling. Automated microfluidics excels in parallel processing and environmental control but offers less dexterity for arbitrary single-cell motion. Microrobots provide mobile, reconfigurable interaction but introduce localization and multi-agent control challenges [80]. Micropipette/microneedle systems provide direct intracellular access at the cost of invasiveness and relatively low throughput. Platform selection should therefore follow the biological task and the measurable performance requirements summarized in Table 1.

3.2. Integration and Hybrid Automated Systems

To assess research activity in integrated optical-tweezer–microfluidic cell manipulation, a Web of Science Core Collection search was conducted using the Topic query “optical tweezers cell manipulation” AND “microfluidic.” The search returned 191 publications from 2010 to 2025 and 12 records indexed for 2026 at the time of data collection. As shown in Figure 10, annual output reached 18 publications in both 2011 and 2014 and remained active in recent years, with 33 records published during 2023–2025. The three-year moving average indicates sustained interest in this integration pathway. Although publication activity alone does not establish a universal performance advantage, these results support the relevance of examining how optical tweezers and microfluidics can provide complementary capabilities for precise manipulation, controlled transport, sorting, and sample processing.
Figure 10. Web of Science publication trend for integrated optical-tweezer–microfluidic cell manipulation from 2010 onward. Bars represent annual publications, and the red line represents the three-year moving average. The 2026 value represents a partial publication year.
Physical integration combines complementary actuation mechanisms within a shared workspace. Wang et al. [38] combined optical tweezers with a microfluidic chip, using fluidic transport for sample handling and optical forces for localized cell manipulation. This arrangement adds dexterous single-cell positioning to flow-based transport, but it retains limitations associated with optical exposure, restricted working volume, and alignment between the optical and microfluidic subsystems. More recent work has demonstrated non-invasive cell manipulation using single-fiber optical tweezers in a lens-integrated microfluidic device, where the microcapillary geometry enhanced optical focusing while separating the probe from the sample [81]. Microfluidic–microrobotic architectures provide a different form of physical integration. Hagiwara et al. [14] demonstrated high-speed magnetic microrobot actuation within a microfluidic chip, where the channel geometry constrained the workspace while magnetic actuation supplied mobile manipulation. Hayakawa et al. [60] further integrated an on-chip nanorobot with functional nanomaterials for localized single-cell puncture. These systems improve access and dexterity in confined environments, although their performance depends on chip geometry, external actuation equipment, localization accuracy, optical exposure, and reliable tool release or withdrawal after contact.
The literature also includes integrated systems combining optical tweezers with microfluidic transport, sorting, cell stretching, and environmental control [82,83,84,85,86,87]. Related hybrid platforms have integrated robotic manipulators or magnetic microrobots with microfluidic chips for oocyte loading, embryo vitrification, cell injection, reconfigurable fluid handling, and confined particle transport [44,46,88,89,90,91,92]. Liang et al. [46] mounted a microfluidic chip on a robotic manipulator to automate oocyte loading and reloading. The principal contribution of this architecture is not merely the coexistence of robotics and microfluidics, but the coordinated transfer of biological samples between successive operations. However, this integration introduces additional requirements for coordinate registration, subsystem synchronization, repeated calibration, contamination control, and recovery from unsuccessful loading events. At the sensing and control level, shared visual, force, fluorescence, impedance, or acoustic measurements can support supervisory decisions across multiple stages. Nevertheless, heterogeneous sampling rates, latency, coordinate frames, and uncertainty models remain barriers to unified closed-loop operation.
These examples demonstrate that hybridization does not automatically improve overall performance. Its value depends on whether the additional subsystem resolves a defined bottleneck and whether the resulting benefit exceeds the added calibration, fabrication, control, and validation burden. Integrated platforms should therefore be evaluated using end-to-end measures such as hand-off success, total workflow time, calibration frequency, contamination events, manipulation success, post-procedure viability, and overall sample yield. Most available studies emphasize subsystem-level demonstrations rather than workflow-level outcomes, which currently limits rigorous quantitative comparison among hybrid architectures.
Representative examples of integrated and hybrid automated cell manipulation platforms are summarized in Table 2. These systems illustrate how complementary manipulation modalities can be combined to address specific limitations of individual technologies. Examples include optical tweezers integrated with microfluidics for precise positioning in controlled fluidic environments, magnetic microrobots integrated with microfluidic chips for mobile and repeatable cell transport, robotic manipulators combined with microfluidic devices for automated oocyte handling, and on-chip nanorobotic tools for localized single-cell intervention. However, integration also introduces additional challenges related to subsystem alignment, calibration, synchronization, localization, contamination control, and cross-platform validation. These factors must be addressed to achieve reliable and scalable operation.
Table 2. Representative integrated and hybrid automated cell manipulation platforms.

3.3. Cross-Platform Future Directions and Standardization

Despite significant technological progress, several challenges continue to hinder the widespread adoption and clinical translation of robotic cell manipulation systems. A major limitation is the absence of standardized benchmarking protocols that enable objective comparison of different robotic platforms across laboratories. Future studies should establish common evaluation metrics, including positioning accuracy, manipulation success rate, throughput, cell viability, intracellular delivery efficiency, and long-term biological functionality following manipulation. In parallel, the increasing integration of artificial intelligence, multimodal sensing, and data-driven control offers new opportunities for adaptive robotic manipulation capable of responding to biological variability in real time. The development of open datasets, standardized experimental protocols, and reproducible validation procedures will further accelerate algorithm development and facilitate meaningful comparisons among different technologies. Ultimately, the combination of hybrid robotic architectures, intelligent automation, and standardized performance evaluation will play a critical role in advancing robotic cell manipulation from laboratory demonstrations toward reliable biomedical and clinical applications. Recent developments in biohybrid microrobots further demonstrate that successful clinical translation will depend not only on advances in actuation and control, but also on improved biocompatibility, adaptive navigation, and standardized validation under physiologically relevant conditions [61].
Standardized reporting should include target type and preparation, task definition, workspace and medium, actuation parameters, sensing rate and latency, positioning or pose error, throughput, manipulation success, post-procedure viability, failure modes, and duration of autonomous operation. For hybrid systems, investigators should additionally report hand-off success, total workflow time, calibration frequency, contamination events, and end-to-end yield. These measures would support fairer cross-laboratory comparison and more credible translation.

4. Conclusions

Automated single-cell manipulation is better understood as a family of complementary platform archetypes than as a single hierarchy of robotic devices. Optical tweezers offer precise non-contact interaction, automated microfluidics provides parallel processing and environmental control, microrobots add mobile and reconfigurable manipulation, and micropipette/microneedle systems provide direct intracellular access. Their performance must be judged against application-specific requirements and under explicitly reported experimental conditions.
The strongest path forward is integration supported by shared sensing, supervisory control, standardized metrics, and transparent reporting of failure and viability. Such a framework can convert isolated demonstrations into reproducible workflows and clarify which combinations of precision, throughput, dexterity, and biological safety are technically achievable.

Funding

The author would like to acknowledge the support provided by King Fahd University of Petroleum & Minerals (KFUPM) for funding this work though project No. IN26064.

Data Availability Statement

No new data were created or analyzed in this study. Data sharing is not applicable to this article.

Acknowledgments

The author would like to acknowledge the support provided by the Deanship of Research (DR) at King Fahd University of Petroleum & Minerals (KFUPM) for funding this work through project No. IN26064. During the preparation of this manuscript, the author used ChatGPT (GPT-5.6 Sol; OpenAI) to improve the English language, grammar, clarity, and readability of the text. All AI-assisted content was subsequently reviewed and edited by the author, who takes full responsibility for the accuracy and integrity of the final manuscript.

Conflicts of Interest

The author declares no conflicts of interest.

References

  1. Gayathri, R.; Kar, S.; Nagai, M.; Mahapatra, P.S.; Santra, T.S. Massively Parallel High-Throughput Single-Cell Patterning and Large Biomolecular Delivery in Mammalian Cells Using Light Pulses. Small 2023, 19, 2303053. [Google Scholar] [CrossRef] [Scilit]
  2. Xie, M.Y.; Wang, Y.; Feng, G.; Sun, D. Automated Pairing Manipulation of Biological Cells with a Robot-Tweezers Manipulation System. IEEE-ASME Trans. Mechatron. 2015, 20, 2242–2251. [Google Scholar] [CrossRef] [Scilit]
  3. Shakoor, A.; Wang, B.; Fan, L.; Kong, L.; Gao, W.; Sun, J.; Man, K.; Li, G.; Sun, D. Automated Optical Tweezers Manipulation to Transfer Mitochondria from Fetal to Adult MSCs to Improve Antiaging Gene Expressions. Small 2021, 17, 2103086. [Google Scholar] [CrossRef] [Scilit]
  4. Xie, M.Y.; Shakoor, A.; Shen, Y.J.; Mills, J.K.; Sun, D. Out-of-Plane Rotation Control of Biological Cells with a Robot-Tweezers Manipulation System for Orientation-Based Cell Surgery. IEEE Trans. Biomed. Eng. 2019, 66, 199–207. [Google Scholar] [CrossRef] [Scilit]
  5. Xie, M.Y.; Mills, J.K.; Wang, Y.; Mahmoodi, M.; Sun, D. Automated Translational and Rotational Control of Biological Cells with a Robot-Aided Optical Tweezers Manipulation System. IEEE Trans. Autom. Sci. Eng. 2016, 13, 543–551. [Google Scholar] [CrossRef] [Scilit]
  6. Xie, M.Y. Autonomous robot-aided optical tweezer system for biological cell manipulation. Int. J. Adv. Manuf. Technol. 2019, 105, 4953–4966. [Google Scholar] [CrossRef] [Scilit]
  7. Yang, H.; Li, X.P.; Liu, Y.H.; Sun, D. Automated Transportation of Biological Cells for Multiple Processing Steps in Cell Surgery. IEEE Trans. Autom. Sci. Eng. 2017, 14, 1712–1721. [Google Scholar] [CrossRef] [Scilit]
  8. Coluccio, M.L.; Perozziello, G.; Malara, N.; Parrotta, E.; Zhang, P.; Gentile, F.; Limongi, T.; Raj, P.M.; Cuda, G.; Candeloro, P.; et al. Microfluidic platforms for cell cultures and investigations. Microelectron. Eng. 2019, 208, 14–28. [Google Scholar] [CrossRef] [Scilit]
  9. Tang, T.; Zhao, H.; Shen, S.F.; Yang, L.K.; Lim, C.T. Enhancing single-cell encapsulation in droplet microfluidics with fine-tunable on-chip sample enrichment. Microsyst. Nanoeng. 2024, 10, 3. [Google Scholar] [CrossRef] [Scilit]
  10. Choi, S.; Lee, H.; Lee, S.; Park, I.; Kim, Y.S.; Key, J.; Lee, S.Y.; Yang, S.; Lee, S.W. A novel automatic segmentation and tracking method to measure cellular dielectrophoretic mobility from individual cell trajectories for high throughput assay. Comput. Methods Programs Biomed. 2020, 195, 105662. [Google Scholar] [CrossRef] [Scilit]
  11. Shen, Y.G.; Song, Z.Y.; Yan, Y.M.; Song, Y.X.; Pan, X.X.; Wang, Q. Automatic and Selective Single Cell Manipulation in a Pressure-Driven Microfluidic Lab-On-Chip Device. Micromachines 2017, 8, 172. [Google Scholar] [CrossRef] [Scilit]
  12. Miao, S.; Jia, Y.Y.; Jiang, Z.; Xu, J.H.; Li, X. Cell Cryopreservation in a Microfluidic Chip with Vision-Based Fluid Control and Region Reaching. IEEE Trans. Autom. Sci. Eng. 2025, 22, 9327–9337. [Google Scholar] [CrossRef] [Scilit]
  13. Zhang, Y.; Wang, F.; Ye, Y.; Guo, X.; Wang, X.; Knoll, A.; Wang, Y.; Dai, C.; Ying, Y.; Zhou, M. Enhanced Automated Cell Micromanipulation via Programmable Magnetic Microgripper Design. IEEE Trans. Autom. Sci. Eng. 2025, 22, 10107–10117. [Google Scholar] [CrossRef] [Scilit]
  14. Hagiwara, M.; Kawahara, T.; Iijima, T.; Arai, F. High-Speed Magnetic Microrobot Actuation in a Microfluidic Chip by a Fine V-Groove Surface. IEEE Trans. Robot. 2013, 29, 363–372. [Google Scholar] [CrossRef] [Scilit]
  15. Wang, Z.Q.; Zhang, Y.; Zhang, Y.; Zhang, D.; Chu, Z.; Zhao, Q.; Sun, M.; Cui, M.; Zhao, X.; Liu, Y. Prediction-Based Method for Micropipette Approaching to Optimal Spindle Removal Position. IEEE Trans. Autom. Sci. Eng. 2025, 22, 11894–11905. [Google Scholar] [CrossRef] [Scilit]
  16. Pan, F.; Chen, S.X.; Jiao, Y.; Guan, Z.Y.; Shakoor, A.; Sun, D. Automated High-Productivity Microinjection System for Adherent Cells. IEEE Robot. Autom. Lett. 2020, 5, 1167–1174. [Google Scholar] [CrossRef] [Scilit]
  17. Sun, M.Z.; Yao, Y.; Zhao, X.; Li, L.; Gong, H.; Qiu, J.; Liu, Y.; Zhao, X. Precise Aspiration and Positioning Control Based on Dynamic Model Inside and Outside the Micropipette. IEEE Trans. Autom. Sci. Eng. 2023, 20, 385–393. [Google Scholar] [CrossRef] [Scilit]
  18. Li, R.M.; Li, M.; Qiu, J.; Li, K.; Liu, Y.; Cui, C.; Fu, S.; Ma, B.; Zhang, Q.; Cui, M.; et al. Precise Robotic Picking Up of Polar Body for Biopsy Application. IEEE Trans. Autom. Sci. Eng. 2025, 22, 5895–5905. [Google Scholar] [CrossRef] [Scilit]
  19. Wei, Y.Z.; Xu, Q.S. A Survey of Force-Assisted Robotic Cell Microinjection Technologies. IEEE Trans. Autom. Sci. Eng. 2019, 16, 931–945. [Google Scholar] [CrossRef] [Scilit]
  20. Shakoor, A.; Xie, M.; Luo, T.; Hou, J.; Shen, Y.; Mills, J.K.; Sun, D. Achieving automated organelle biopsy on small single cells using a cell surgery robotic system. IEEE Trans. Biomed. Eng. 2019, 66, 2210–2222. [Google Scholar] [CrossRef] [Scilit]
  21. Shaw, L.A.; Chizari, S.; Hopkins, J.B. Improving the throughput of automated holographic optical tweezers. Appl. Opt. 2018, 57, 6396–6402. [Google Scholar] [CrossRef] [Scilit]
  22. Hu, S.Y.; Xie, H.; Wei, T.Y.; Chen, S.X.; Sun, D. Automated Indirect Transportation of Biological Cells with Optical Tweezers and a 3D Printed Microtool. Appl. Sci. 2019, 9, 2883. [Google Scholar] [CrossRef] [Scilit]
  23. Hu, S.Y.; Chen, S.X.; Chen, S.; Xu, G.; Sun, D. Automated Transportation of Multiple Cell Types Using a Robot-Aided Cell Manipulation System with Holographic Optical Tweezers. IEEE-ASME Trans. Mechatron. 2017, 22, 804–814. [Google Scholar] [CrossRef] [Scilit]
  24. Moura, D.S.; Silva, D.C.N.; Williams, A.J.; Bezerra, M.A.C.; Fontes, A.; de Araujo, R.E. Automatic real time evaluation of red blood cell elasticity by optical tweezers. Rev. Sci. Instrum. 2015, 86, 053702. [Google Scholar] [CrossRef] [Scilit]
  25. Yan, X.; Cheah, C.C.; Ta, Q.M.; Pham, Q.C. Stochastic Dynamic Trapping in Robotic Manipulation of Micro-Objects Using Optical Tweezers. IEEE Trans. Robot. 2016, 32, 499–512. [Google Scholar] [CrossRef] [Scilit]
  26. Chen, H.Y.; Wang, C.; Li, X.J.; Sun, D. Transportation of Multiple Biological Cells Through Saturation-Controlled Optical Tweezers in Crowded Microenvironments. IEEE-ASME Trans. Mechatron. 2016, 21, 888–899. [Google Scholar] [CrossRef] [Scilit]
  27. Li, X.; Cheah, C.C. A Simple Trapping and Manipulation Method of Biological Cell Using Robot-Assisted Optical Tweezers: Singular Perturbation Approach. IEEE Trans. Ind. Electron. 2017, 64, 1656–1663. [Google Scholar] [CrossRef] [Scilit]
  28. Kawakami, M.; Kojima, M.; Masuda, Y.; Mae, Y.; Horii, T.; Nagai, T.; Nakahata, M.; Sakai, S.; Arai, T. Automated Microhand System for Measuring Cell Stiffness by Using Two Plate End-Effectors. IEEE Robot. Autom. Lett. 2022, 7, 2385–2390. [Google Scholar] [CrossRef] [Scilit]
  29. Huang, K.C.; Abu Ajamieh, A.; Cui, Z.X.; Lai, J.W.; Mills, J.K.; Chu, H.K. Automated Embryo Manipulation and Rotation via Robotic nDEP-Tweezers. IEEE Trans. Biomed. Eng. 2021, 68, 2152–2163. [Google Scholar] [CrossRef] [Scilit]
  30. Dannenberg, P.H.; Kang, J.; Martino, N.; Kashiparekh, A.; Forward, S.; Wu, J.; Liapis, A.C.; Wang, J.; Yun, S.-H. Laser particle activated cell sorting in microfluidics. Lab Chip 2022, 22, 2343–2351. [Google Scholar] [CrossRef] [Scilit]
  31. Li, R.; Li, J.; Li, Z.; Qiu, J.; Hu, B.; Li, M.; Sun, M.; Zhao, X.; Zhao, Q. Robotic Fluorescent Lighting Method based on Dynamic Fluorescence Imaging Modeling for In Vivo Cell Manipulation. IEEE Trans. Autom. Sci. Eng. 2025, 22, 13716–13727. [Google Scholar] [CrossRef] [Scilit]
  32. Yan, X.; Fu, X.; Hong, Y.; Wang, J.; Ruan, Y. Synchronization control for optical micromanipulation of cell ensembles with shape constraints. Commun. Nonlinear Sci. Numer. Simul. 2026, 158, 109856. [Google Scholar] [CrossRef] [Scilit]
  33. Yan, X.; Fu, X.; Hong, Y.; Ruan, Y. A theoretical framework for dynamic cell patterning and synchronization using optical tweezers. Eur. Phys. J. Plus 2025, 140, 449. [Google Scholar] [CrossRef] [Scilit]
  34. Li, X.; Yan, X.; Cheah, C.C. Robot-assisted optical trapping and manipulation of a biological cell with stochastic perturbations. In Proceedings of the 2016 IEEE International Conference on Robotics and Automation (ICRA), Stockholm, Sweden, 16–21 May 2016; IEEE: New York, NY, USA, 2016; pp. 5236–5241. [Google Scholar] [CrossRef] [Scilit]
  35. Xie, M.; Shakoor, A.; Wu, Z.; Jiang, B. Optical Manipulation of Biological Cells with a Robot-Tweezers System: A Stochastic Control Approach. IEEE Trans. Circuits Syst. II Express Briefs 2020, 67, 3232–3236. [Google Scholar] [CrossRef] [Scilit]
  36. Zhukov, A.A.; Pritchard, R.H.; Withers, M.J.; Hailes, T.; Gold, R.D.; Hayes, C.; la Cour, M.F.; Hussein, F.; Rogers, S.S. Extremely High-Throughput Parallel Microfluidic Vortex-Actuated Cell Sorting. Micromachines 2021, 12, 389. [Google Scholar] [CrossRef] [Scilit]
  37. Tu, J.; Qiao, Y.; Xu, M.; Li, J.; Liang, F.; Duan, M.; Ju, A.; Lu, Z. A cell sorting and trapping microfluidic device with an interdigital channel. AIP Adv. 2016, 6, 125042. [Google Scholar] [CrossRef] [Scilit]
  38. Wang, X.; Chen, S.; Kong, M.; Wang, Z.; Costa, K.D.; Li, R.A.; Sun, D. Enhanced cell sorting and manipulation with combined optical tweezer and microfluidic chip technologies. Lab Chip 2011, 11, 3656–3662. [Google Scholar] [CrossRef] [Scilit]
  39. Ahmadi, F.; Samlali, K.; Vo, P.Q.N.; Shih, S.C.C. An integrated droplet-digital microfluidic system for on-demand droplet creation, mixing, incubation, and sorting. Lab Chip 2019, 19, 524–535. [Google Scholar] [CrossRef] [Scilit]
  40. Jia, Z.Q.; Jiang, C.; Li, J.; Belgaid, Y.; Ge, M.; Li, L.; Hu, S.; Huang, X.; Ho, T.-Y.; Dong, W.; et al. Intelligent single-cell manipulation: LLMs- and object detection-enhanced active-matrix digital microfluidics. Microsyst. Nanoeng. 2025, 11, 133. [Google Scholar] [CrossRef] [Scilit]
  41. Xu, J.Y.; Chen, S.; Wang, D.; Jiang, Y.; Hao, M.; Du, G.; Ba, D.; Lin, Q.; Mei, Q.; Ning, Y.; et al. A Microfluidic Chip with Double-Slit Arrays for Enhanced Capture of Single Cells. Micromachines 2018, 9, 157. [Google Scholar] [CrossRef] [Scilit]
  42. Nguyen, T.H.; Thi, N.A.N.; Thu, H.B.; Bui, T.T.; Duc, T.C.; Quang, L.D. Design and proof-of-concept of a micropillar-based microfluidic chip for trapping and culture of single cells. Microfluid. Nanofluidics 2024, 28, 35. [Google Scholar] [CrossRef] [Scilit]
  43. Song, J.; Ryu, H.; Chung, M.; Kim, Y.; Blum, Y.; Lee, S.S.; Pertz, O.; Jeon, N.L. Microfluidic platform for single cell analysis under dynamic spatial and temporal stimulation. Biosens. Bioelectron. 2018, 104, 58–64. [Google Scholar] [CrossRef] [Scilit]
  44. Miao, S.; Xu, J.; Jiang, Z.; Luo, J.; Sun, X.; Jiang, X.; Wei, H.; Liu, Y.-H. Microfluidics-Enabled Robotic System for Embryo Vitrification with Real-Time Observation: Design, Method, and Evaluation. IEEE-ASME Trans. Mechatron. 2024, 29, 179–189. [Google Scholar] [CrossRef] [Scilit]
  45. Miao, S.; Guo, C.; Jiang, Z.; Wei, H.-X.; Jiang, X.; Gu, J.; Hai, Z.; Wang, T.; Liu, Y.-H. Development of an Open Microfluidic Platform for Oocyte One-Stop Vitrification with Cryotop Method. Biosensors 2022, 12, 766. [Google Scholar] [CrossRef] [Scilit]
  46. Liang, S.Z.; Amaya, S.; Sugiura, H.; Mo, H.; Dai, Y.G.; Arai, F. A Microfluidic Chip on a Robotic Manipulator for Loading and Reloading of Oocytes. Adv. Intell. Syst. 2024, 6, 2400185. [Google Scholar] [CrossRef] [Scilit]
  47. Huang, S.H.; Hung, L.Y.; Lee, G.B. Continuous nucleus extraction by optically-induced cell lysis on a batch-type microfluidic platform. Lab Chip 2016, 16, 1447–1456. [Google Scholar] [CrossRef] [Scilit]
  48. Wang, Z.; Kelley, S.O. Microfluidic technologies for enhancing the potency, predictability and affordability of adoptive cell therapies. Nat. Biomed. Eng. 2025, 9, 803–821. [Google Scholar] [CrossRef] [Scilit]
  49. Chowdhury, S.; Jing, W.M.; Cappelleri, D.J. Controlling multiple microrobots: Recent progress and future challenges. J. Microbio Robot. 2015, 10, 1–11. [Google Scholar] [CrossRef] [Scilit]
  50. Kantaros, Y.; Johnson, B.V.; Chowdhury, S.; Cappelleri, D.J.; Zavlanos, M.M. Control of Magnetic Microrobot Teams for Temporal Micromanipulation Tasks. IEEE Trans. Robot. 2018, 34, 1472–1489. [Google Scholar] [CrossRef] [Scilit]
  51. Yashinski, M. Collection of microrobots for gentle cell manipulation. Sci. Robot. 2024, 9, eads619. [Google Scholar] [CrossRef] [Scilit]
  52. Charreyron, S.L.; Boehler, Q.; Danun, A.N.; Mesot, A.; Becker, M.; Nelson, B.J. A Magnetically Navigated Microcannula for Subretinal Injections. IEEE Trans. Biomed. Eng. 2021, 68, 119–129. [Google Scholar] [CrossRef] [Scilit]
  53. Pieters, R.; Lombriser, S.; Alvarez-Aguirre, A.; Nelson, B.J. Model Predictive Control of a Magnetically Guided Rolling Microrobot. IEEE Robot. Autom. Lett. 2016, 1, 455–460. [Google Scholar] [CrossRef] [Scilit]
  54. Kirmizitas, F.C.; Rivas, D.P.; Sokolich, M.; McNeill, J.M.; Dutta, A.; Das, S. CAMP: Closed-Loop Acoustic-Magnetic Propulsion of Microrobots for Precision Cell Manipulation. Adv. Intell. Syst. 2025, 7, e202500300. [Google Scholar] [CrossRef] [Scilit]
  55. Wang, F.H.; Zhang, Y.; Jin, D.; Jiang, Z.; Liu, Y.; Knoll, A.; Jiang, H.; Ying, Y.; Zhou, M. Magnetic Soft Microrobot Design for Cell Grasping and Transportation. Cyborg Bionic Syst. 2024, 5, 0109. [Google Scholar] [CrossRef] [Scilit]
  56. Grammatikopoulou, M.; Yang, G.Z. Three-Dimensional Pose Estimation of Optically Transparent Microrobots. IEEE Robot. Autom. Lett. 2020, 5, 72–79. [Google Scholar] [CrossRef] [Scilit]
  57. Jing, W.M.; Chowdhury, S.; Guix, M.; Wang, J.; An, Z.; Johnson, B.V.; Cappelleri, D.J. A Microforce-Sensing Mobile Microrobot for Automated Micromanipulation Tasks. IEEE Trans. Autom. Sci. Eng. 2019, 16, 518–530. [Google Scholar] [CrossRef] [Scilit]
  58. Al Khatib, E.; Zhang, X.; Kim, M.J.; Hurmuzlu, Y. Teleoperation control scheme for magnetically actuated microrobots with haptic guidance. J. Microbio Robot. 2020, 16, 161–171. [Google Scholar] [CrossRef] [Scilit]
  59. Feng, L.; Di, P.; Arai, F. High-precision motion of magnetic microrobot with ultrasonic levitation for 3-D rotation of single oocyte. Int. J. Robot. Res. 2016, 35, 1445–1458. [Google Scholar] [CrossRef] [Scilit]
  60. Hayakawa, T.; Fukada, S.; Arai, F. Fabrication of an On-Chip Nanorobot Integrating Functional Nanomaterials for Single-Cell Punctures. IEEE Trans. Robot. 2014, 30, 59–67. [Google Scholar] [CrossRef] [Scilit]
  61. Quan, X.; Sun, B.; Song, X.; Zhang, L. Biophysics-informed design of biohybrid microrobots. Nat. Rev. Bioeng. 2026, 4, 559–579. [Google Scholar] [CrossRef] [Scilit]
  62. Zhang, Z.R.; Wang, X.; Liu, J.; Dai, C.S.; Sun, Y. Robotic Micromanipulation: Fundamentals and Applications. Annu. Rev. Control. Robot. Auton. Syst. 2019, 2, 181–203. [Google Scholar] [CrossRef] [Scilit]
  63. Zhuang, S.L.; Dai, C.S.; Shan, G.Q.; Ru, C.H.; Zhang, Z.R.; Sun, Y. Robotic Rotational Positioning of End-Effectors for Micromanipulation. IEEE Trans. Robot. 2022, 38, 2251–2261. [Google Scholar] [CrossRef] [Scilit]
  64. Zhao, Q.L.; Sun, M.Z.; Cui, M.S.; Yu, J.; Qin, Y.D.; Zhao, X. Robotic Cell Rotation Based on the Minimum Rotation Force. IEEE Trans. Autom. Sci. Eng. 2015, 12, 1504–1515. [Google Scholar] [CrossRef] [Scilit]
  65. Gao, X.; Deng, J.; Wang, W.; Chang, Q.; Sun, J.; Liu, J.; Zhang, S.; Liu, Y. A Compact 2-DOF Cross-Scale Piezoelectric Robotic Manipulator with Adjustable Force for Biological Delicate Puncture. IEEE Trans. Robot. 2024, 40, 4561–4577. [Google Scholar] [CrossRef] [Scilit]
  66. Qiu, J.Y.; Zhu, R.; Zhang, Y.; Li, M.; Li, R.; Fu, S.; Zhao, X.; Zhao, Q. Robotic Microscopic Vision-Free Cell Transportation Based on Pressure Variation Model Inside Bilayer Micropipette. IEEE Trans. Autom. Sci. Eng. 2025, 22, 4134–4144. [Google Scholar] [CrossRef] [Scilit]
  67. Dai, C.S.; Shan, G.Q.; Liu, X.J.; Ru, C.H.; Xin, L.M.; Sun, Y. Automated Orientation Control of Motile Deformable Cells. IEEE Trans. Autom. Sci. Eng. 2023, 20, 2126–2134. [Google Scholar] [CrossRef] [Scilit]
  68. Liu, J.; Zhang, Z.; Wang, X.; Liu, H.; Zhao, Q.; Zhou, C.; Tan, M.; Pu, H.; Xie, S.; Sun, Y. Automated Robotic Measurement of 3-D Cell Morphologies. IEEE Robot. Autom. Lett. 2017, 2, 499–505. [Google Scholar] [CrossRef] [Scilit]
  69. Dai, C.S.; Zhang, Z.; Lu, Y.; Shan, G.; Wang, X.; Zhao, Q.; Ru, C.; Sun, Y. Robotic Manipulation of Deformable Cells for Orientation Control. IEEE Trans. Robot. 2020, 36, 271–283. [Google Scholar] [CrossRef] [Scilit]
  70. Chau, C.C.; Maffeo, C.M.; Aksimentiev, A.; Radford, S.E.; Hewitt, E.W.; Actis, P. Single molecule delivery into living cells. Nat. Commun. 2024, 15, 4403. [Google Scholar] [CrossRef] [Scilit]
  71. Dai, C.S.; Xin, L.; Zhang, Z.; Shan, G.; Wang, T.; Zhang, K.; Wang, X.; Chu, L.-T.; Ru, C.; Sun, Y. Design and Control of a Piezo Drill for Robotic Piezo-Driven Cell Penetration. IEEE Robot. Autom. Lett. 2020, 5, 339–345. [Google Scholar] [CrossRef]
  72. Dai, C.S.; Zhuang, S.L.; Shan, G.Q.; Ru, C.H.; Zhang, Z.R.; Sun, Y. Automated End-Effector Alignment in Robotic Micromanipulation. IEEE-ASME Trans. Mechatron. 2022, 27, 3932–3941. [Google Scholar] [CrossRef] [Scilit]
  73. Feng, K.; Xu, Q.S.; Tam, L.M. Design and Development of a Teleoperated Robotic Microinjection System with Haptic Feedback. IEEE Robot. Autom. Lett. 2021, 6, 6092–6099. [Google Scholar] [CrossRef] [Scilit]
  74. Shang, W.F.; Lu, H.J.; Yang, Y.Y.; Shen, Y.J. 7-DoFs Rotation-Thrust Microrobotic Control for Low-Invasive Cell Pierce via Impedance Compensation. IEEE-ASME Trans. Mechatron. 2022, 27, 5095–5106. [Google Scholar] [CrossRef] [Scilit]
  75. Gong, H.Y.; Li, L.; Qiu, J.; Yao, Y.; Liu, Y.; Cui, M.; Zhao, Q.; Zhao, X.; Sun, M. Automatic Cell Rotation Based on Real-Time Detection and Tracking. IEEE Robot. Autom. Lett. 2021, 6, 7910–7917. [Google Scholar] [CrossRef] [Scilit]
  76. Pan, F.; Jiao, Y.; Chen, S.X.; Xing, L.X.; Sun, D. Deep Learning-Enhanced Dual-Module Large-Throughput Microinjection System for Adherent Cells. IEEE Trans. Autom. Sci. Eng. 2023, 20, 2409–2422. [Google Scholar] [CrossRef] [Scilit]
  77. Shan, G.Q.; Zhang, Z.R.; Dai, C.S.; Wang, X.; Chu, L.T.; Sun, Y. Model-Based Robotic Cell Aspiration: Tackling Nonlinear Dynamics and Varying Cell Sizes. IEEE Robot. Autom. Lett. 2020, 5, 173–178. [Google Scholar] [CrossRef] [Scilit]
  78. Dai, C.S.; Shan, G.Q.; Liu, H.; Ru, C.H.; Sun, Y. Robotic Manipulation of Sperm as a Deformable Linear Object. IEEE Trans. Robot. 2022, 38, 2799–2811. [Google Scholar] [CrossRef] [Scilit]
  79. Song, H.C.; Chen, W.; Shan, G.; Dai, C.; Yang, S.; Jiang, A.; Liu, H.; Zhang, Z.; Sun, Y. Automated Sperm Tracking and Immobilization with a Clinically-Compatible XYZ Stage. IEEE Trans. Autom. Sci. Eng. 2025, 22, 10764–10774. [Google Scholar] [CrossRef] [Scilit]
  80. Medany, M.; Mukkavilli, S.K.; Ahmed, D. AI-driven autonomous microrobots for targeted medicine. Nat. Rev. Bioeng. 2024, 2, 914–915. [Google Scholar] [CrossRef] [Scilit]
  81. Jiang, C.; Wang, Y.; Dong, T.; Li, D.; Yan, B.; Chen, P.; Shao, K.; Wang, X.; Wang, Z. Completely non-invasive cell manipulation in lens-integrated microfluidic devices by single-fiber optical tweezers. Opt. Lett. 2023, 48, 2130–2133. [Google Scholar] [CrossRef] [Scilit]
  82. Enger, J.; Goksor, M.; Ramser, K.; Hagberg, P.; Hanstorp, D. Optical tweezers applied to a microfluidic system. Lab Chip 2004, 4, 196–200. [Google Scholar] [CrossRef] [Scilit]
  83. Eriksson, E.; Enger, J.; Nordlander, B.; Erjavec, N.; Ramser, K.; Goksör, M.; Hohmann, S.; Nyström, T.; Hanstorp, D. A microfluidic system in combination with optical tweezers for analyzing rapid and reversible cytological alterations in single cells upon environmental changes. Lab Chip 2007, 7, 71–76. [Google Scholar] [CrossRef] [Scilit]
  84. Landenberger, B.; Höfemann, H.; Wadle, S.; Rohrbach, A. Microfluidic sorting of arbitrary cells with dynamic optical tweezers. Lab Chip 2012, 12, 3177–3183. [Google Scholar] [CrossRef] [Scilit]
  85. Yao, Z.; Kwan, C.C.; Poon, A.W. An optofluidic ‘tweeze-and-drag’ cell stretcher in a microfluidic channel. Lab Chip 2020, 20, 601–613. [Google Scholar] [CrossRef] [Scilit]
  86. Wang, Y.; Dai, X.; Jiang, Q.; Fan, H.; Li, T.; Xia, X.; Dou, Y.; Mao, Y. Fluorescence imaging-activated microfluidic particle sorting using optical tweezers. Biosensors 2025, 15, 541. [Google Scholar] [CrossRef] [Scilit]
  87. Cieslik, J.P.; Xia, X.; Salehi-Reyhani, A. MaGIC-OT: An AI-guided optical tweezers platform for autonomous single-cell isolation in microfluidic devices. Lab Chip 2026, 26, 2451–2462. [Google Scholar] [CrossRef] [Scilit]
  88. Liang, S.; Mo, H.; Dai, Y.; Sugiura, H.; Amaya, S.; Arai, F. Dual vision-equipped microfluidic chip for spatiotemporal sequential pick-and-place of oocytes. LabChip 2026, 26, 2355–2367. [Google Scholar] [CrossRef] [Scilit]
  89. Zhou, Q.; Song, B.; Feng, Y.; Feng, L. Cell injection microrobot development and evaluation in microfluidic chip. In Proceedings of the 2018 International Symposium on Micro-NanoMechatronics and Human Science (MHS), Nagoya, Japan, 9–12 December 2018; IEEE: New York, NY, USA, 2018. [Google Scholar] [CrossRef] [Scilit]
  90. Chen, Y.; Xu, Z.; Sun, Y.; Xu, Q. Design of a reconfigurable microfluidic system enabled by magnetic miniature robots. Adv. Intell. Syst. 2025, 8, e202500745. [Google Scholar] [CrossRef] [Scilit]
  91. Sharma, P.K.; Lu, T.-Y.; Chen, C.-Y. Modular reconfiguration and actuation of microrobotic assemblies. iScience 2026, 29, 117208. [Google Scholar] [CrossRef] [Scilit]
  92. Feng, L.; Zhou, Q.; Song, B.; Feng, Y.; Cai, J.; Jiang, Y.; Zhang, D. Cell injection millirobot development and evaluation in microfluidic chip. Micromachines 2018, 9, 590. [Google Scholar] [CrossRef] [Scilit]
  93. Hayakawa, T.; Arai, F. Fabrication and manipulation of 3D hybrid nanorobot for single cell puncture. In Proceedings of the 2013 International Symposium on Micro-NanoMechatronics and Human Science (MHS), Nagoya, Japan, 10–13 November 2013; IEEE: New York, NY, USA, 2013; pp. 1–2. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.