Hybrid Thermoelectric Generation Characterization Platform

,
,
and
1
Research Group on Energy & Energy Sustainability (GPEnSE), Center for Alternative and Renewable Research (CEAR), Federal University of Paraiba (UFPB), João Pessoa 58051-900, PB, Brazil
2
Graduate Program in Mechanical Engineering (PPGEM), Technology Center (CT), Federal University of Paraiba (UFPB), João Pessoa 58051-900, PB, Brazil
3
Interdisciplinary Postgraduate Program in Energy and Sustainability (PPGIES), Federal University of Latin American Integration (UNILA), Foz do Iguaçu 85867-000, PR, Brazil
4
Faculdade de Engenharia Elétrica e de Computação (FEEC), Universidade Estadual de Campinas (UNICAMP), Av. Albert Einstein 400, Campinas 13083-852, SP, Brazil

Abstract

The growing adoption of thermoelectric generators (TEGs) and solar thermoelectric generators (STEGs) for energy harvesting has increased the demand for flexible experimental platforms capable of controlled electrothermal testing under diverse thermal excitation conditions. This paper presents the development and experimental demonstration of a hybrid thermoelectric experimental platform for controlled electrothermal investigations, integrating ceramic positive temperature coefficient (PTC) heating, controlled halogen-based optical irradiation, multistage thermoelectric cooling with active liquid heat rejection, embedded PID-based thermal regulation, and synchronized thermal and electrical data acquisition. An ESP32-WROOM-32-based supervisory system provides autonomous control, remote monitoring, and the independent regulation of the heating and cooling subsystems. Under the investigated conditions, cold-side temperatures approached −40 °C, while hot-side temperatures approached 200 °C under resistive excitation and approximately 170 °C under maximum optical excitation; sustained controlled optical operation was limited to approximately 150 °C. Four independently calibrated NTC temperature channels exhibited a maximum observed calibration deviation within ±1% over the evaluated ranges, representing calibration performance rather than the combined uncertainty of the complete measurement system. Timestamp-based alignment of thermal and electrical measurements resulted in a residual digital synchronization skew below 50 ms, characterizing the temporal alignment of the recorded data streams rather than the physical response time of the temperature sensors. In a transient TEG experiment, the platform produced a maximum externally measured temperature difference of approximately 161.74 K and a transient open-circuit voltage peak of 1.7818 V, demonstrating temporally aligned observation of thermal and electrical responses during controlled thermal conditioning and passive relaxation. These quantities characterize the transient system-level response under the imposed experimental boundary conditions rather than a direct determination of intrinsic TEG properties. Overall, the results demonstrate the coordinated operation of hybrid thermal excitation, multistage cooling, embedded control, and synchronized electrothermal acquisition within a single reconfigurable experimental infrastructure for TEG- and STEG-oriented investigations.

1. Introduction

The increasing global demand for energy efficiency has intensified the development of Energy Harvesting technologies aimed at converting residual energy into usable electrical power [1,2,3]. In this context, Thermoelectric Generators (TEGs) and Solar Thermoelectric Generators (STEGs) have emerged as promising alternatives for waste heat recovery and low-power distributed generation due to their capability to directly convert thermal gradients into electricity through the Seebeck effect [4,5,6,7].
Significant advances in thermoelectric materials science have been achieved over recent decades, primarily focusing on improving the thermoelectric figure of merit (ZT) to maximize energy conversion efficiency [1,2,3]. However, despite the progress in thermoelectric materials, experimental module-level characterization and metrological standardization remain critical challenges for the practical consolidation of thermoelectric systems [8]. Recent interlaboratory investigations reported deviations exceeding 20% for key thermoelectric parameters, revealing limitations associated with thermal contact resistance, non-uniform heat flux distribution, insufficient thermal stability, and poor experimental repeatability [8].
The electrothermal performance of TEG and STEG devices strongly depends on the capability of the experimental platform to establish and maintain controlled thermal gradients across the Device Under Test (DUT) [3,8]. Variations in thermal interfaces, heat rejection conditions, or thermal excitation stability may affect the determination of open-circuit voltage, internal resistance, maximum power point, and conversion efficiency. Consequently, experimental infrastructures intended for thermoelectric investigations must provide adequate control and monitoring of the thermal boundary conditions imposed on the DUT.
Several experimental platforms for thermoelectric characterization have been proposed in the literature. Previous studies, including earlier works by the authors’ research group, have developed dedicated experimental systems for conventional TEG characterization under controlled thermal gradients, enabling the acquisition of characteristic electrical and thermal parameters [9,10,11,12,13]. Nevertheless, most existing systems remain focused on conventional resistive heating approaches for TEG characterization and do not provide, within the same experimental infrastructure, thermal excitation mechanisms suitable for both conventional TEG and optically excited STEG investigations [9,10,11,12,13]. Furthermore, heat rejection architectures are commonly based on passive dissipators or thermoelectric cooling arrangements, and the achievable thermal conditions depend on the cooling configuration and heat rejection capability [14,15,16,17,18].
Another relevant aspect is that several characterization systems rely on external supervisory computers and dedicated instrumentation for thermal control, monitoring, and data acquisition, increasing operational complexity and laboratory infrastructure requirements. Recent advances in embedded systems and IoT-based monitoring architectures demonstrate the feasibility of compact supervisory platforms for thermal and electrothermal applications [19,20,21,22]. However, experimental infrastructures simultaneously integrating different thermal excitation mechanisms, multistage thermoelectric cooling, embedded supervisory control, remote monitoring, and electrothermal data acquisition remain scarcely explored in the literature.
Table 1 presents a comparative analysis between representative thermoelectric characterization approaches reported in the literature and the experimental infrastructure developed in this work. The comparison considers attributes relevant to the intended functionality of the proposed platform, including characterization scope, reported thermal operating range, thermal excitation mechanism, cooling architecture, temperature and electrical acquisition, embedded supervisory control, optical excitation, and transient acquisition capability. Because the referenced studies differ in purpose, measurement methodology, and experimental scope, the comparison is intended to identify differences in system architecture and functionality rather than to establish a ranking of metrological performance.
Table 1. Functional comparison of the proposed platform with representative thermoelectric characterization approaches reported in the literature.
As shown in Table 1, the evaluated platforms address different experimental requirements, including conventional TEG characterization, photovoltaic–thermoelectric methodologies, thermoelectric materials investigations, and thermoelectric efficiency measurement [9,10,11,12,13]. Within this context, the architecture developed in this work combines, in a single experimental infrastructure, resistive and radiative thermal excitation, multistage thermoelectric cooling with active liquid heat rejection, embedded supervisory control, remote monitoring, and temperature and electrical acquisition. This combination was adopted to provide a reconfigurable experimental environment capable of supporting both TEG- and STEG-oriented investigations under different thermal boundary conditions.
A relevant distinction of the proposed architecture is therefore not a claim of superior metrological performance relative to dedicated thermoelectric measurement systems, but the integration of complementary experimental functions within a single platform. Dedicated metrological arrangements may provide capabilities such as controlled heat-flow measurement and uncertainty analysis [12], whereas the platform developed here is primarily intended to establish, control, monitor, and record different electrothermal operating conditions for thermoelectric devices, supporting functional and system-level investigations under controlled thermal boundary conditions rather than reproducing standardized component-level characterization conditions. In particular, the combination of an ESP32-based supervisory system, independent thermal control loops, multichannel acquisition, and remote monitoring reduces dependence on an external supervisory computer while enabling coordinated operation of the thermal subsystems.
In this context, the present work aims to design, develop, and experimentally demonstrate a hybrid thermoelectric experimental platform for controlled electrothermal investigations of TEG and STEG devices. The proposed platform integrates hybrid thermal excitation based on ceramic PTC heating and controlled optical irradiation, multistage cascade thermoelectric cooling, embedded supervisory control, and synchronized multichannel electrothermal data acquisition. The developed architecture was conceived to provide a wide range of controlled thermal conditions and to support both transient and quasi-steady experimental procedures.
The focus of this work is therefore the development and functional demonstration of the integrated experimental infrastructure, rather than the establishment of a reference metrological facility or the complete validation of a specific thermoelectric characterization method. Accordingly, the experiments are intended to assess the coordinated operation of the platform and the electrothermal response of the DUT under the imposed experimental boundary conditions, rather than to reproduce manufacturer characterization curves obtained under different standardized test conditions. The experiments reported herein are used to demonstrate the operation of the heating, cooling, radiative excitation, sensing, control, and acquisition subsystems, as well as their coordinated operation during representative electrothermal experiments. Parameters requiring dedicated metrological procedures, such as direct heat-flow measurement and complete propagated measurement uncertainty, are outside the measurement capabilities demonstrated by the present platform.
Mechanical and thermal stability are supported by an adjustable fixation mechanism with thermal expansion compensation and expanded polyurethane thermal insulation. Operational control is performed by an ESP32-WROOM-32 microcontroller (Espressif Systems, Shanghai, China) [13], enabling remote supervisory operation through an embedded web interface, synchronized data acquisition, and multivariable thermal regulation using high-current H-bridge drivers module based on the BTS7960 half-bridge (Infineon Technologies AG, Munich, Germany) [16,17,23].
Experimental assessment was conducted through procedures applied to the resistive heating, multistage thermoelectric cooling, optical excitation, and electrothermal acquisition subsystems. The experiments demonstrated operation over a wide thermal range, reaching temperatures close to −40 °C on the cold side, 200 °C under PTC resistive excitation, and 170 °C under halogen irradiation under the experimental conditions investigated. For continuous operation, the hot-side temperature was limited to approximately 150 °C in order to preserve the integrity of thermally sensitive components.
The obtained results demonstrate the functional integration of the thermal excitation, cooling, sensing, control, and acquisition subsystems and their applicability to transient electrothermal investigations of thermoelectric devices. Rather than constituting a standardized metrological characterization system, the developed platform provides a reconfigurable experimental infrastructure for imposing and monitoring controlled thermal conditions relevant to TEG and STEG research.
This research is part of an ongoing research and development (R&D) effort conducted by the Energy and Sustainability Research Group (GPEnSE), focused on solid-state generators, self-powered devices, autonomous sensors, and thermoelectric energy harvesting systems for terrestrial and aerospace applications [7,9,13,24,25,26,27,28,29]. Building upon these developments, the present paper addresses the need for a unified experimental infrastructure capable of supporting both Thermoelectric Generator (TEG) and Solar Thermoelectric Generator (STEG) investigations under controlled thermal and radiative operating conditions.
The main contributions of this paper are summarized as follows:
  • Development of a Hybrid Thermoelectric Characterization Platform: Design and implementation of an autonomous experimental infrastructure supporting controlled electrothermal investigations of both TEG and STEG devices within a single platform, combining resistive and optical thermal excitation mechanisms.
  • Integration of Multistage Thermoelectric Cooling and Hybrid Thermal Excitation: Implementation of an asymmetric cascade refrigeration architecture coupled with active liquid recirculation, enabling operation over an extended thermal range from approximately −40 °C to 150 °C during continuous operation.
  • Development of an Autonomous Embedded Supervisory System: Implementation of an ESP32-based control architecture incorporating independent PID thermal regulation loops, synchronized multichannel acquisition, remote web-based monitoring, and experimental operation without dependence on external supervisory infrastructure.
  • Demonstration of Wide-Range Thermal Operation and Electrothermal Characterization Capability: Experimental assessment of the heating, cooling, irradiation, and acquisition subsystems, demonstrating stable operation from approximately −40 °C to 200 °C and enabling transient electrothermal characterization of thermoelectric devices under large thermal gradients.
  • Unified Infrastructure for TEG and STEG Characterization: Development of a versatile experimental platform capable of supporting controlled electrothermal investigations of conventional TEGs as well as optical-irradiation experiments for integrated STEG devices, addressing a gap commonly observed in existing thermoelectric testing platforms.
The technological relevance of the developed architecture is also supported by the software registration granted by the Brazilian National Institute of Industrial Property (INPI) under registration number BR512026002394 [30], as well as by the patent application associated with the complete characterization platform architecture, currently under analysis by INOVA-UFPB.
This paper is structured to guide the reader through the development and experimental assessment of the Hybrid Thermoelectric Characterization Platform for TEG and STEG devices. Section 2 describes the materials, design methodology, mechanical architecture, thermal subsystems, and embedded control and acquisition systems employed in the development of the platform. Section 3 presents the experimental procedures applied to the heating, cooling, irradiation, and electrothermal acquisition subsystems. Section 4 discusses the obtained results, including transient electrothermal behavior, thermal stability, thermal homogeneity, and operational limitations of the proposed architecture. Finally, Section 5 summarizes the main conclusions and outlines future research directions.

2. Materials and Methods

The development of the proposed hybrid thermoelectric characterization platform followed a mechatronic design methodology integrating mechanical, thermal, electronic, and supervisory control requirements into a unified experimental infrastructure. The primary objective was to provide a versatile and autonomous platform capable of supporting controlled electrothermal investigations of both conventional Thermoelectric Generators (TEGs) and Solar Thermoelectric Generators (STEGs) under transient and steady-state operating conditions.
From a design perspective, the platform was conceived to address several limitations commonly reported in thermoelectric characterization systems, including restricted thermal operating ranges, insufficient thermal stability, limited control of thermal boundary conditions, dependence on external laboratory instrumentation, and the absence of integrated support for STEG characterization under controlled optical irradiation [5,10,28]. To overcome these challenges, the proposed architecture combines hybrid thermal excitation, multistage thermoelectric cooling, embedded supervisory control, synchronized electrothermal acquisition, and autonomous operation within a single experimental environment.
The complete system was initially modeled using Computer-Aided Design (CAD) techniques in the Autodesk Inventor environment (version 2024, Autodesk, Inc., San Francisco, CA, USA) to support the mechanical integration of thermal, fluidic, and electronic subsystems. To improve thermal management, assembly consistency, and operational flexibility, the platform was physically organized into three modular sectors arranged linearly, comprising structural, thermodynamic, and electronic subsystems. This modular configuration facilitates assembly, maintenance, thermal isolation, subsystem scalability, and the future integration of additional experimental capabilities.
Figure 1 compares the CAD-based conceptual design with the fully assembled experimental prototype, highlighting the physical arrangement of the heating, cooling, sensing, control, and fluid recirculation subsystems. Table 2 summarizes the main technical specifications, operational limits, and instrumentation employed in the developed characterization platform.
Figure 1. Overall architecture of the hybrid thermoelectric characterization platform: (a) CAD-based conceptual design and (b) fully assembled experimental prototype. The three main functional sectors are graphically identified in both views: S1, primary cooling and heat-rejection stage; S2, liquid recirculation and thermal-management stage; and S3, thermoelectric characterization chamber containing the hot- and cold-side thermal interfaces for DUT testing.
Table 2. Technical specifications of the proposed characterization bench.
The following subsections describe the mechanical design, thermal subsystems, embedded supervisory architecture, instrumentation, control strategies, and experimental procedures adopted during the development and experimental assessment of the proposed platform.

2.1. Structural Design and Mechanical Project

The mechanical structure of the characterization platform was manufactured from laser-cut and bent steel plates, providing high torsional rigidity to withstand thermal and mechanical stresses during operation. The structural assembly employs threaded rivets and stainless-steel fasteners to improve mechanical integrity and long-term durability.
The platform was designed to accommodate TEG- and STEG-oriented DUTs within the 100 mm × 100 mm maximum test area specified for the thermal interfaces. The DUT is positioned between the opposing thermal surfaces so that the imposed temperature difference is predominantly established across the module thickness. For DUTs with lateral dimensions smaller than the 100 mm × 100 mm test surfaces, the uncovered peripheral regions are filled with solid thermal insulation material to reduce parasitic convective heat exchange and promote preferential heat transfer through the active DUT region [8].
The thermal coupling of the Device Under Test (DUT) requires adequate and spatially distributed mechanical contact across the thermal interfaces, since variations in contact conditions can affect interfacial thermal resistance and experimental repeatability in thermoelectric measurements [8]. In the developed structure, mechanical loading is provided by parallel shafts, screws, and compression springs acting on the thermal assembly. The spring-loaded arrangement maintains contact between the opposing thermal surfaces while accommodating dimensional variations caused by thermal expansion during heating and cooling cycles.
This compliant fixation mechanism is particularly relevant because the copper heat spreaders operate over a wide temperature range, reaching temperatures approaching 200 °C under the investigated peak conditions. Thermal expansion of these components can modify the relative position of the thermal interfaces and compromise planar contact if a completely rigid fixation arrangement is employed. The compression springs therefore provide passive mechanical compensation during thermal cycling, reducing the sensitivity of the assembly to thermally induced dimensional changes.
The applied contact force and the corresponding interface pressure were not instrumented or independently quantified in the present platform. Consequently, the spring-loaded mechanism should be interpreted as a means of maintaining mechanical contact and accommodating thermal expansion rather than as a calibrated pressure-control system. The mechanical configuration was maintained consistently throughout the reported experiments; however, this configuration control should not be interpreted as quantitative control of the resulting contact pressure. The influence of contact pressure on the effective thermal resistance of the DUT interfaces is therefore not independently determined in the present work and constitutes a limitation when interpreting absolute thermoelectric parameters that depend on the temperature difference directly across the active thermoelectric junctions.

2.2. Primary Thermal System

Sector 1 is dedicated to the primary thermal rejection stage of the platform, operating as the main thermal sink for the circulating coolant fluid.
As illustrated in Figure 2, the cooling arrangement adopts a sandwich-type thermoelectric configuration centered on an aluminum heat exchanger through which the cooling fluid circulates. Four TEC1-12715 commercial bismuth telluride thermoelectric modules [31] were mounted onto the heat exchanger using high-performance thermal pads with thermal conductivity of 24 W/m·K and thickness of 0.5 mm.
Figure 2. Detailed view of the primary cooling stage responsible for heat extraction from the recirculating fluid.
Thermoelectric cooling systems require highly efficient hot-side heat dissipation to avoid thermal saturation and Joule heat accumulation [14,15,16,17]. Heat rejection to the environment is performed through copper heat spreaders coupled to Storm 8 air-cooling systems (Rise Mode, São Paulo, Brazil) equipped with eight heat pipes and forced-air ventilation.
To maximize thermal efficiency and minimize condensation effects, the entire assembly was encapsulated using polyurethane foam and aluminized thermal insulation blankets, forming a radiative thermal barrier.
The fluid recirculation subsystem (Sector 2), illustrated in Figure 3, employs an automotive expansion reservoir coupled to a 12 V recirculation pump (WP680 model, generic COTS component), capable of delivering a nominal flow rate of 800 L/h. The cooling medium consists of antifreeze solution transported through 10 mm silicone hoses insulated using tubular elastomeric foam, contributing to thermal stabilization and reduction in environmental heat exchange.
Figure 3. Expansion reservoir and recirculation pump integrated into the closed-loop fluid circuit.

2.3. Multistage and Hybrid Thermal System

Sector 3 contains the main thermoelectric characterization chamber illustrated in Figure 4.
Figure 4. Multistage cascade cooling architecture integrated with the fluid recirculation system.
To overcome the thermodynamic limitations associated with single-stage thermoelectric cooling systems [14,15,16,17,18], the cold-side architecture employs an asymmetric cascade cooling configuration. The base stage consists of a Storm 8 heat sink coupled to a TEC1-12715 thermoelectric module [31]. Above the intermediate aluminum block, the secondary stage incorporates two TEC2-19008 thermoelectric modules [32], providing the multistage refrigeration required to establish low-temperature boundary conditions at the cold-side test surface.
The multistage cooling architecture operates in conjunction with the active liquid heat-rejection circuit shown in Figure 4, which removes the heat rejected by the thermoelectric cascade. Under the experimental conditions investigated in this work, the cold-side system reached temperatures approaching −40 °C. This value represents the minimum temperature observed for the tested configuration and operating conditions and should not be interpreted as a load-independent cooling specification. The achievable cold-side temperature depends on the thermal load imposed on the refrigeration stages and on the heat-rejection conditions of the cascade. A systematic characterization of minimum cold-side temperature as a function of applied thermal load was not performed in the present work.
The hot-side test surface employs a hybrid thermal excitation architecture. In conventional TEG characterization mode, thermal excitation is provided by two 12 V ceramic PTC heaters rated for operation up to 200 °C. PTC heaters inherently exhibit self-regulated thermal behavior, reducing thermal overshoot and simplifying PID-based thermal stabilization [16,17,18,33,34].
For STEG-oriented experiments, the PTC heating module can be replaced by the radiative excitation stage illustrated in Figure 5.
Figure 5. Controlled irradiation stage configured for STEG characterization mode.
The irradiation subsystem employs a halogen AR111 lamp with G53 base (12 V, 50 W, and 24° beam angle Ourolux Comercial Ltd.a., São Paulo, Brazil) integrated into a dual-contact halogen reflector housing with 118 mm length and R7s base, providing localized radiative excitation directly onto the DUT absorber surface. Owing to the directional beam of the AR111 source, the radiative excitation is spatially concentrated, with greater thermal concentration occurring in the central region of the irradiated area. Therefore, the optical subsystem is not assumed to provide spatially uniform irradiance over the complete test surface.
The halogen-based optical subsystem is employed in this work as a controlled radiative thermal excitation source for STEG-oriented experiments and is not intended to reproduce a standardized solar spectrum. Optical sources intended for standardized photovoltaic testing are evaluated in terms of spectral match, spatial irradiance non-uniformity over the test plane, and temporal irradiance instability. These parameters were not experimentally determined for the present optical subsystem, and the incident irradiance was not measured using a calibrated reference cell, pyranometer, or spectroradiometer. Consequently, the AR111 source is not classified in this work as a standardized solar simulator, and no equivalence to standard solar irradiance conditions, such as 1 sun, is claimed. Its present function is limited to providing controlled localized radiative excitation for evaluating the thermal and transient response of the developed platform and the DUT under the imposed irradiation conditions.

2.4. Thermal Sensing and Power Electronics

The cold-side sensing system employs redundant 10 kΩ NTC thermistors positioned directly between the thermal interface and the test surface. On the hot side, cylindrical 100 kΩ NTC thermistors were inserted into transverse cavities machined into the copper heat spreaders.
The separation of the sensing elements according to their operational temperature range was adopted to provide adequate sensitivity over the different thermal conditions investigated. The 10 kΩ NTC thermistors are employed over the nominal range from −40 °C to 50 °C for cold-side monitoring, whereas the 100 kΩ NTC thermistors are employed from 0 °C to 200 °C for hot-side measurements. The use of independent sensors at each thermal interface also enables comparison between spatially separated temperature measurements during the experimental procedures.
The thermal interfaces were filled with industrial-grade thermal compound featuring high thermal conductivity and a wide operational temperature range, promoting thermal coupling between the sensing elements and the corresponding measurement surfaces while protecting the sensors during prolonged thermal exposure. Because the temperature sensors measure the local temperature at their respective installation positions, the resulting hot- and cold-side measurements represent the temperatures at these external sensing locations rather than direct measurements of the active thermoelectric junction temperatures within the DUT. The measured values may also be influenced by sensor positioning, thermal contact conditions, and spatial temperature gradients across the thermal interfaces. These contributions were not independently quantified in the present experimental campaign and are therefore considered measurement limitations rather than included in the reported calibration deviation.
PID regulation of the PTC heating system and fine cooling control through the TEC2-19008 modules are performed using BTS7960B-based driver modules (Infineon Technologies AG, Munich, Germany) [23]. Configured as dual H-bridge drivers, these modules support high-current PWM operation for thermal actuation and closed-loop temperature regulation [16,17,18,23].

2.5. Embedded Web Server and DAQ

The supervisory architecture of the characterization platform is based on an ESP32-WROOM-32 microcontroller [19]. The selection of this System-on-Chip (SoC) is justified by the integration of 12-bit ADC converters and native Wi-Fi connectivity, enabling the implementation of an embedded web server without requiring external communication peripherals [19,20,21,22].
The switching logic for pumps and primary TEC modules is performed through six isolated relay channels. Figure 6 presents the complete embedded supervisory interface developed for thermal control and monitoring.
Figure 6. Embedded web interface for thermal control, monitoring, configuration, and data acquisition: (a) main control interface with the thermal actuators inactive, showing the four temperature channels, calculated temperature difference, data-logging controls, and subsystem status; (b) configuration interface for clock synchronization, PID parameters, and temperature-sensor calibration; and (c) main control interface during active operation, showing PTC and Peltier actuation and the enabled liquid-pump and refrigeration stages.
The embedded interface performs the acquisition and digital filtering of the signals generated by the NTC thermistor network through individual resistive divider circuits connected to the ESP32 ADC inputs. The temperature measurement subsystem comprises four independent NTC channels, including two 10 kΩ thermistors for cold-side measurements and two 100 kΩ thermistors for hot-side measurements. The 10 kΩ sensors are employed over the nominal range from −40 °C to 50 °C, whereas the 100 kΩ sensors are employed from 0 °C to 200 °C.
To compensate for the nonlinear response and individual variation in the thermistors, each channel incorporates a six-point calibration procedure with independent adjustment of the measurement curve, offset, and β parameter. After calibration, the maximum observed deviation relative to the reference measurements remained within ±1% over the corresponding evaluated ranges. Accordingly, the ±1% value is reported as an empirical calibration-performance bound for the evaluated calibration points and ranges. This value represents the experimentally observed calibration deviation in the individual temperature channels and not the combined measurement uncertainty of the complete platform.
The thermal regulation system is implemented using two independent discrete PID controllers, one associated with the hot-side PTC heating system and the other with the cold-side thermoelectric cooling system. The PTC controller uses the A3 temperature channel as feedback, whereas the thermoelectric cooling controller uses the A1 channel. The control algorithm is executed at 10 Hz, corresponding to a 100 ms control interval. The PID parameters used during the experimental campaign were Kp = 20.0, Ki = 0.5 and Kd = 100.0 for the PTC controller, and Kp = 40.0, Ki = 2.0, and Kd = 200.0 for the thermoelectric cooling controller. The controller parameters were experimentally adjusted based on step-response tests of the respective thermal subsystems.
The actuator commands are generated through PWM modulation at 100 Hz for the PTC heater and 10 kHz for the thermoelectric cooling stage. The control implementation includes conditional integral accumulation with integral-state limiting, output saturation within the available PWM range, and asymmetric output ramping to reduce abrupt changes in actuator excitation. The temperature signals used by the controllers are obtained after ADC averaging and digital filtering, with a filter coefficient of α = 0.05.
For dynamic electrothermal experiments, temporal correspondence between the thermal and electrical measurements is established through timestamp-based synchronization. The thermal control and temperature acquisition loop operates at 10 Hz, whereas the experimental data are recorded at an effective logging rate of 1 Hz. Each recorded temperature and voltage measurement is assigned an individual timestamp based on the host operating-system clock using Epoch time with millisecond resolution. The two data streams are subsequently aligned during post-processing by matching the corresponding timestamps, allowing the thermal and electrical measurements to be paired on a common temporal basis.
The residual temporal offset associated with USB latency and network transmission delays was quantified as less than 50 ms. This value represents the residual digital synchronization skew between the recorded data streams and should not be interpreted as the physical response time of the temperature sensors. The thermal response of the NTC sensors is additionally influenced by their physical construction, installation, thermal coupling, and the thermal mass of the measurement interface. The corresponding sensor time constants were not independently characterized in the present experimental campaign. Consequently, the <50 ms value characterizes the temporal alignment of the acquisition system rather than the overall dynamic response of the temperature measurement chain.
The supervisory platform enables multichannel acquisition, remote monitoring, and autonomous thermal control, reducing dependence on an external supervisory computer. The integrated architecture combines calibrated temperature channels, closed-loop thermal regulation, timestamp-aligned electrothermal acquisition, and embedded supervisory functions within a unified experimental environment. The main measurement characteristics and calibration performance are summarized in Table 3.
Table 3. Measurement Characteristics and Calibration Performance.
The quantitative values reported in Table 3 describe the instrument specifications and experimentally observed calibration performance available for the present measurement configuration. In particular, the ±1% value associated with the NTC channels represents the maximum observed deviation obtained after the six-point calibration procedure and should not be interpreted as the combined uncertainty of the complete electrothermal measurement system.
For the electrical measurement, the UNI-T UT61E+ (Uni-Trend Technology (China) Co., Ltd., Dongguan, China) provides a DC-voltage resolution of 0.0001 V and a specified accuracy of ± (0.05% + 5 digits). For the temperature channels, acquisition is performed through the 12-bit ADC, while the experimentally determined calibration performance is represented by the maximum observed deviation of ±1%. For temporal alignment, the independently timestamped thermal and electrical data streams exhibited a residual digital synchronization skew below 50 ms.
A complete propagated measurement uncertainty would additionally require the quantitative treatment of contributions that were not independently characterized during the present experimental campaign, including the complete thermistor measurement-chain uncertainty, ADC-related effects beyond the reported acquisition resolution, sensor positioning and thermal coupling, DUT-to-interface thermal contact resistance and its dependence on the unquantified contact pressure, spatial temperature gradients across the interfaces, and the physical response time of the temperature sensors. These effects are therefore not combined with the calibration deviation reported in Table 3.
Accordingly, the measurement information presented here is intended to document the sensing and acquisition performance used for the functional demonstration of the developed platform, rather than to establish a metrology-grade uncertainty budget for thermoelectric module calibration. Determination of a complete propagated uncertainty would require a dedicated metrological characterization beyond the experimental scope of the present work.

3. Experimental Procedures

To experimentally assess the operation of the developed hybrid thermoelectric characterization platform, independent experimental procedures were conducted using the resistive heating, multistage thermoelectric cooling, and controlled optical excitation subsystems. The experiments were designed to examine the thermal response, temperature-control behavior, thermal-gradient generation capability, and electrothermal acquisition functions of the platform under representative operating conditions for Thermoelectric Generator (TEG)- and Solar Thermoelectric Generator (STEG)-oriented experiments.
The experimental procedures were organized in a modular manner, allowing the individual assessment of the thermal subsystems and the subsequent integrated operation of the thermal and electrical acquisition architecture. During these experiments, the transient thermal response, temperature evolution at spatially separated sensing positions, control behavior, and synchronized multichannel data acquisition were evaluated.
The experiments also established the temperatures reached by the developed architecture under the investigated resistive-heating, radiative-excitation, and multistage-cooling conditions. These values represent the experimentally observed operating conditions of the present configuration rather than load-independent thermal specifications. The procedures described in the following subsections therefore provide a functional experimental assessment of the platform and the basis for the transient electrothermal analysis presented in Section 4.

3.1. Resistive Heating

The resistive heating procedure was conducted to evaluate the transient thermal response and heating capability of the proposed hybrid characterization platform under controlled ceramic PTC excitation. The experiment was performed using the resistive heating subsystem operating under embedded PID-based thermal regulation [16,17,18].
The experiments were carried out in a temperature-controlled environment to reduce external thermal disturbances. Temperature acquisition was performed using two independent 100 kΩ NTC thermistors positioned at opposite extremities of the copper heat spreader located on the hot-side surface. The two sensing positions were used to monitor the temperature evolution at spatially separated locations of the heat spreader during the heating process [8].
The experimental procedure consisted of a step-response test in which the heating system was driven toward maximum thermal excitation conditions corresponding to 100% PWM duty cycle. However, because of the characteristic electrical behavior of ceramic PTC heaters, the instantaneous application of maximum excitation may produce elevated inrush current when the heating elements are initially at low temperature. This behavior results from the lower initial electrical resistance of the ceramic PTC elements under cold-start conditions [33,34].
The thermal-control parameters for the PTC heating subsystem were experimentally adjusted from step-response tests performed on the thermal plant. The resulting discrete PID controller employed Kp = 20.0, Ki = 0.5, and Kd = 100.0, with a control-update interval of 100 ms (10 Hz). The PTC actuator was driven using PWM at 100 Hz. The controller output was limited to the available PWM range and incorporated conditional integral accumulation, integral-state limiting, and progressive output ramping to reduce abrupt actuator transitions during heating. These parameters were maintained throughout the experiments reported in this work.
To reduce transient electrical stress and abrupt power-supply loading, a progressive PWM soft-start strategy was implemented during the initial stage of the experiment. As the temperature of the ceramic heaters increases, the self-regulating electrical behavior of the PTC elements increases their electrical resistance, reducing the current demand. Thermal actuation was subsequently regulated through the embedded PID controller based on PWM modulation [16,17,18,33,34].
The experiment started from an ambient temperature close to 25 °C. During the procedure, the supervisory system progressively increased the excitation applied to the PTC heaters while the controller regulated the thermal actuation.
The transient thermal response obtained during the experimental procedure is presented in Figure 7. Both temperature channels exhibit the progressive temperature increase in the hot-side assembly and similar temporal behavior. Temperatures approaching 200 °C were reached under the investigated peak operating conditions.
Figure 7. Transient thermal response of the PTC resistive heating subsystem using two independent temperature monitoring channels positioned at opposite extremities of the copper heat spreader.
The difference between the two sensing channels represents the temperature difference observed between the corresponding measurement positions on the copper heat spreader. Because only two local temperature measurements were employed, these measurements characterize the monitored positions and should not be interpreted as a complete spatial temperature map of the test surface. The magnitude and temporal evolution of this difference are analyzed quantitatively in Section 4.

3.2. Controlled Optical Irradiation

The controlled optical irradiation procedure was conducted to evaluate the transient thermal response produced by the radiative excitation subsystem under STEG-oriented operating conditions [5,10,28]. The experiment employed the halogen irradiation subsystem integrated into the hot-side thermal excitation structure.
The experimental setup utilized an AR111 halogen lamp with G53 base rated at 12 V and 50 W, featuring a 24° beam angle. The irradiation source was positioned at a fixed distance of approximately 15 cm from the test surface, maintaining the same source-to-surface geometry during the experiment.
Unlike the resistive heating experiment, no copper heat spreader plate was employed between the irradiation source and the temperature sensing elements during this procedure. Temperature acquisition was performed using two independent 100 kΩ NTC thermistors exposed to the radiative heating condition and positioned longitudinally at different regions of the irradiated area. This configuration enabled comparison of the local thermal responses at the two monitored positions under the directional radiation field generated by the AR111 source. Because the sensors measure local temperature rather than incident radiative heat flux, these measurements do not constitute a quantitative spatial irradiance map.
In practical STEG configurations, the temperature sensors may be positioned between the photovoltaic cell and the thermoelectric module or attached to the photovoltaic surface using Kapton polyimide tape. Under such conditions, the influence of the fixation interface and local thermal coupling must be considered when interpreting the measured temperatures.
The experimental procedure consisted of a step-response test in which the optical excitation system was driven toward its maximum operating condition corresponding to 100% PWM duty cycle applied to the halogen source. Because of the electrical transient associated with cold-start operation of the halogen filament, a progressive PWM soft-start strategy was implemented during the initial stage of the experiment to reduce abrupt electrical loading of the subsystem [16,17,18].
The thermal-control parameters for the optical heating subsystem were adjusted experimentally from step-response tests of the halogen-based thermal plant. The same hot-side PID-controller architecture was used, with Kp = 20.0, Ki = 0.5, and Kd = 100.0, updated at 10 Hz and applied to the 100 Hz PWM excitation of the halogen source. Although temperatures approaching 170 °C were observed under maximum excitation, the closed-loop operating temperature was limited to approximately 150 °C to avoid excessive thermal loading of the experimental assembly and temperature-sensitive components.
The experiments were carried out under ambient temperature conditions close to 25 °C. Thermal actuation was regulated through embedded PID control based on PWM modulation [16,17,18].
Figure 8 presents the transient thermal response obtained during controlled optical irradiation. The two channels exhibit progressive temperature increases under radiative excitation, with differences between the temperatures measured at the two monitored positions.
Figure 8. Transient thermal response of the controlled halogen irradiation subsystem using two independent thermal monitoring channels longitudinally positioned within the irradiated area.
Temperatures approaching 170 °C were observed under the investigated peak excitation condition. The difference between the two sensing channels is consistent with different local thermal responses within the directional irradiation region. As established in Section 2.3, however, spatial irradiance non-uniformity was not independently quantified using a calibrated radiometric measurement system. The temperature measurements presented here therefore characterize the thermal response at the two sensor locations and are not used to claim spatially uniform irradiance or to quantify radiative heat-flux uniformity over the complete test area.

3.3. Multistage TEC

The multistage thermoelectric cooling (TEC) procedure was conducted to evaluate the transient thermal response and cooling capability of the cascade thermoelectric refrigeration architecture. The experiment employed the complete cooling subsystem operating together with the active liquid recirculation system and embedded PWM-based thermal regulation.
The experimental setup utilized the asymmetric cascade cooling architecture composed of TEC1-12715 and TEC2-19008 commercial bismuth telluride thermoelectric modules coupled to the liquid recirculation system described in Section 2. Thermoelectric modules simultaneously perform heat pumping while generating Joule heat during operation, requiring heat rejection from the cascade during cooling [16,17,18].
Progressive actuation and embedded PID regulation were employed to control the cooling transient and reduce abrupt changes in actuator excitation [16,17,18]. The thermal-control parameters for the multistage thermoelectric cooling subsystem were experimentally adjusted from step-response tests of the refrigeration plant. The discrete PID controller employed Kp = 40.0, Ki = 2.0, and Kd = 200.0, with a control-update interval of 100 ms (10 Hz). The thermoelectric actuator was driven by PWM at 10 kHz. The controller incorporated conditional integral accumulation with integral-state limiting, output saturation, and progressive actuation. The selected parameters were maintained during the experimental cooling procedure.
The experiments were conducted under ambient temperature conditions close to 25 °C. Temperature acquisition was performed using two miniature 10 kΩ tape-type NTC thermistors longitudinally positioned over the 100 mm × 100 mm copper cold plate and underneath the thermal interface pad employed in the experimental assembly.
The experimental procedure consisted of a step-response test in which the cascade thermoelectric system was driven toward its maximum operating condition corresponding to 100% PWM duty cycle. During the experiment, the supervisory system progressively increased the thermoelectric actuation while the liquid recirculation subsystem removed heat rejected from the hot-side stages of the cascade.
Figure 9 presents the transient thermal response obtained during the multistage cooling procedure. Both measurement channels exhibit progressive temperature reduction and similar temporal behavior at the two monitored positions.
Figure 9. Transient thermal response of the multistage thermoelectric cooling subsystem using two miniature 10 kΩ NTC temperature sensors longitudinally positioned over the copper cold plate underneath the experimental thermal interface.
Temperatures approaching −40 °C were reached under the investigated experimental configuration. As discussed in Section 2.3, this value corresponds to the minimum temperature observed under the tested conditions and should not be interpreted as a load-independent cooling specification. A systematic determination of minimum cold-side temperature as a function of externally imposed thermal load was not performed in the present experimental campaign.
The difference between the two sensing channels represents the local temperature difference between the monitored positions on the copper cold plate. Because the experimental arrangement employed two local sensing positions rather than a distributed temperature field measurement, the results do not constitute a complete spatial thermal map of the cold-side test surface. The observed differences between the two channels are quantified and discussed in Section 4.

3.4. Electrothermal Acquisition Procedure

The electrothermal acquisition procedure was developed to examine the temporal relationship between the externally measured temperature difference established across the TEG assembly and its open-circuit electrical response. The ESP32-based supervisory system continuously acquired the hot- and cold-side temperatures at the 10 Hz control and acquisition rate, while the thermal and electrical measurements used for experimental analysis were recorded at an effective logging rate of 1 Hz. The electrical signal was acquired using the multimeter operating in USB datalogger mode.
Each recorded temperature and voltage measurement was associated with an Epoch timestamp with millisecond resolution. The thermal and electrical datasets were subsequently paired during post-processing according to their timestamps. As described in Section 2.5, the residual offset between the recorded data streams associated with USB and network transmission was less than 50 ms. This value represents the residual digital synchronization skew and not the physical response time of the temperature sensors.
The thermoelectric module was mounted using high-thermal-conductivity interface materials and the spring-loaded fixation mechanism described in Section 2.1. The mechanical arrangement maintained contact between the DUT and the thermal interfaces; however, the applied contact force and corresponding interface pressure were not independently quantified. The same mechanical configuration was maintained during the reported experimental procedure, but the resulting contact pressure was not treated as a controlled experimental variable.
The experimental sequence was designed specifically to investigate the transient electrothermal response of the TEG during thermal redistribution. During the preparation stage, the hot- and cold-side thermal subsystems were conditioned to establish the required initial thermal boundary conditions. The TEG was initially coupled to the cold-side refrigeration structure, while the heating structure was thermally separated from the DUT during this conditioning stage. The cold-side system progressively reduced the DUT-side temperature while the heating structure was independently brought to the required thermal condition.
Once the prescribed initial thermal conditions had been established, the heated structure was mechanically coupled to the TEG. The active heating and refrigeration subsystems were then disabled, and temperature and open-circuit voltage acquisition continued during the subsequent passive thermal redistribution of the assembly. This sequence generated a time-varying externally measured temperature difference across the TEG assembly and enabled its corresponding open-circuit voltage response to be recorded during the thermal transient.
The procedure was conceived to reproduce a controlled laboratory thermal transition relevant to the illuminated-to-eclipse thermal transition considered for low Earth orbit applications [24,25,35]. It should therefore be interpreted as a transient electrothermal experiment rather than as a conventional steady-state thermoelectric characterization procedure. Accordingly, the experiment was not designed to reproduce the standardized boundary and interface conditions used for manufacturer-level characterization of an isolated commercial TEG, and direct reproduction of manufacturer performance curves was not an objective of the present procedure.
For the transient analysis presented in this work, data acquisition was maintained continuously during the thermal redistribution process. Consequently, the measurements were not restricted to a final steady-state condition. The relevant quantities are the time-dependent hot-side temperature, cold-side temperature, resulting externally measured temperature difference ΔT(t), and corresponding open-circuit voltage Voc(t). As established by the sensor arrangement described in Section 2.4, ΔT(t) represents the difference between the temperatures measured at the external hot- and cold-side sensing locations and is not interpreted as a direct measurement of the temperature difference between the active thermoelectric junctions. Any portions of the curves exhibiting slowly varying temperatures are treated as quasi-steady intervals only when appropriate and are not assumed to represent complete thermal equilibrium unless explicitly stated.
The acquired thermal and electrical data were temporally aligned and stored by the supervisory acquisition system and subsequently exported in CSV format for transient electrothermal processing and analysis. The resulting thermal and electrical responses are presented and discussed in Section 4.

4. Results and Discussion

This section presents the experimental results obtained using the developed hybrid thermoelectric characterization platform, emphasizing the transient analysis of thermal and electrical variables under different operating conditions. The performed experiments allowed the evaluation of the dynamic behavior of the heating, refrigeration, and synchronized acquisition subsystems, as well as the thermal stability, local temperature differences between monitored positions, and electrothermal response of TEG modules under controlled excitation conditions.
The experimental results are discussed considering the physical mechanisms associated with heat transfer, transient thermal redistribution dynamics, and the thermoelectric conversion process based on the Seebeck effect [1,2,3]. Additionally, operational limitations of the platform and the experimental characteristics observed during active excitation and passive thermal relaxation regimes are analyzed.

4.1. Transient Electrothermal

The experimental methodology was structured to evaluate the transient electrothermal response of the developed platform under controlled initial thermal conditions followed by passive thermal relaxation. As described in Section 3.4, the adopted procedure was not intended to reproduce a conventional steady-state thermoelectric characterization routine. Instead, it was designed to establish independently conditioned hot- and cold-side thermal boundaries and subsequently monitor the time-dependent relationship between the externally measured temperature difference and the open-circuit voltage of the Device Under Test (DUT).
The thermoelectric module was mounted between the thermal interfaces of the characterization platform using high-thermal-conductivity interface materials and the spring-loaded fixation mechanism described in Section 2.1. The mechanical configuration was maintained during the reported experiment, but contact pressure was not treated as a controlled experimental variable. Temperature monitoring was performed using the calibrated NTC channels described in Section 2.4 and Section 2.5.
The experiment employed the ceramic PTC heating subsystem together with the multistage thermoelectric refrigeration architecture. During the initial conditioning stage, the hot and cold thermal structures were operated independently. The TEG remained coupled to the cold-side refrigeration structure, whereas the heating structure was mechanically separated from the DUT. This arrangement allowed the two thermal structures to establish different initial temperature conditions before the transient electrothermal measurement [16,17,18].
The transient thermal response obtained during the experiment is presented in Figure 10a, while the corresponding timestamp-aligned open-circuit voltage is presented in Figure 10b. The results show the temporal correspondence between the externally measured hot- and cold-side temperatures and the electrical response of the TEG during the transition from active thermal conditioning to passive thermal relaxation.
Figure 10. (a) Transient thermal dynamics of the characterization platform during active thermal conditioning and passive thermal relaxation. (b) Corresponding timestamp-aligned open-circuit voltage response of the thermoelectric generator module.
During Region I, the heating and refrigeration subsystems actively conditioned their respective thermal structures while the heating structure remained mechanically decoupled from the TEG. Consequently, Region I should be interpreted primarily as a thermal-conditioning stage used to establish the initial boundary conditions rather than as a steady-state TEG characterization interval. This experimental configuration was conceived to generate a controlled thermal transition relevant to illuminated-to-eclipse transitions considered for LEO applications [7,24].
The transition between the two experimental regimes occurred at approximately 1250 s, corresponding to the beginning of the shaded Region II in Figure 10. This instant represents a deliberately imposed change in the experimental configuration rather than the attainment of cold-side thermal equilibrium. At this point, the previously heated structure was mechanically coupled to the TEG and both active heating and refrigeration subsystems were disabled. The event therefore simultaneously established the conductive thermal path between the previously conditioned hot and cold structures and initiated the passive thermal-relaxation stage.
During Region II, the assembly evolved without active heating or refrigeration. Thermal energy stored in the hot-side structure was redistributed through the TEG/interface assembly toward the colder structure and the surrounding environment. The increase in cold-side temperature following mechanical coupling is therefore consistent with conductive heat transfer through the newly established thermal path and with the finite thermal masses of the experimental assembly. Accordingly, the absence of a cold-side temperature plateau at approximately 1250 s should not be interpreted as failure to reach a required steady-state measurement condition, because the electrothermal experiment was intentionally performed as a transient relaxation test rather than as a steady-state test [14,15,17].
For the electrothermal analysis, the time-dependent externally measured temperature difference was determined as ΔText(t) = Thot,block(t) − Tcold,block(t). This quantity therefore represents the temperature difference between the monitored positions in the hot- and cold-side thermal structures and not a direct measurement of the temperature difference across the active thermoelectric junctions.
Immediately before the transition from thermal conditioning to passive relaxation, the maximum externally measured temperature difference reached approximately 161.74 K. Following mechanical coupling of the previously separated thermal structures, the open-circuit voltage reached a transient maximum of 1.7818 V. The subsequent voltage evolution followed the progressive reduction in the thermal difference during passive thermal redistribution.
Using the peak experimental values directly, the ratio between the measured open-circuit voltage and the externally measured block-to-block temperature difference is αapp = Voc/ΔText = 1.7818/161.74≈0.0110 V/K, or approximately 11.0 mV/K. This quantity is defined here as an apparent system-level electrothermal ratio and should not be interpreted as the intrinsic Seebeck coefficient of the TEG module.
This distinction arises from the temperature measurement locations. According to the measurement convention considered for the commercial 1261G-7L31-24CX1 TEG (Custom Thermoelectric, LLC, Bishopville, MD, USA) used in the experiment, the relevant hot- and cold-side temperatures for module-level electrical performance correspond to temperatures at the TEG interfaces. In the present platform configuration, however, the NTC thermistors were embedded within the copper thermal structures rather than positioned directly at the active TEG interfaces. Consequently, the externally measured difference ΔText is not, in general, equivalent to the actual temperature difference ΔTTEG across the active thermoelectric junctions. The block-to-block measurement includes temperature drops distributed through the thermal interfaces and spreading structures located between the sensor positions and the active thermoelectric region.
For the same reason, the measured Voc and ΔText values should not be used as a direct point-by-point validation against manufacturer performance data obtained under different prescribed interface and thermal-boundary conditions. Such a comparison would require reproducing the relevant manufacturer test conditions and measuring the temperatures at locations representative of the TEG interfaces. The present experiment instead evaluates the transient system-level electrothermal response under the boundary conditions imposed by the developed platform.
This distinction also explains the different hot- and cold-side thermal responses observed after the transition. Once the previously separated structures are mechanically coupled through the TEG assembly, the TEG and its interface layers become part of the conductive thermal path connecting thermal masses initially maintained at substantially different temperatures. The hot-side structure therefore cools while the cold-side structure warms as stored thermal energy is redistributed. In this configuration, the TEG acts not only as the electrical transducer being monitored but also as part of the thermal conduction path between the two sides. This thermal coupling progressively reduces the temperature difference available for thermoelectric generation during Region II.
Because temperatures directly at the TEG faces were not independently measured, the experimental data cannot separate the individual temperature drops associated with the TEG, thermal interface materials, contact conditions, and copper spreading structures. Furthermore, because contact pressure was not independently quantified, its contribution to the effective interface thermal resistance cannot be isolated from these other effects. The present experiment therefore does not provide a direct measurement of contact thermal resistance or an intrinsic Seebeck coefficient. Direct temperature measurements at the hot- and cold-side TEG interfaces, together with the corresponding metrological characterization of the thermal measurement chain and quantified mechanical loading would be required for such a determination.
After the transient voltage maximum, the open-circuit voltage progressively decreased together with the passive thermal relaxation of the experimental assembly. The temporal correspondence between the externally measured temperature difference and Voc is consistent with the expected qualitative Seebeck response of a thermoelectric generator subjected to a time-varying thermal condition [1,2,3]. The experiment therefore demonstrates the capability of the developed acquisition architecture to record temporally aligned thermal and open-circuit electrical variables during a controlled electrothermal transient.
The electrical results presented in Figure 10b must also be distinguished from electrical power and thermoelectric conversion-efficiency measurements. Because the electrical response was acquired under open-circuit conditions, the current delivered to an external load was not measured during this experiment and the open-circuit voltage alone cannot be used to determine generated electrical power. In general, electrical output power requires simultaneous voltage and current under an applied electrical load, Pout = VI. Likewise, thermoelectric conversion efficiency is defined from the ratio between electrical output power and the heat rate entering the hot side, η = P out / Q ˙ h . Because the heat rate Q ˙ h was not directly measured in the present transient experiment, an absolute thermoelectric conversion efficiency cannot be determined from the data in Figure 10.
Accordingly, the results presented in Figure 10 should be interpreted as a functional demonstration of synchronized transient electrothermal acquisition using a commercial TEG, rather than as a complete metrological determination of the intrinsic thermoelectric properties or conversion efficiency of the module.

4.2. Thermal Stability and Spatial Temperature Differences

Thermal stability and spatial temperature differences between monitored positions are relevant parameters in thermoelectric experiments because differences in the thermal boundary conditions can influence the relationship between the measured temperature gradient and the corresponding electrical response [3,8]. The experiments presented in Figure 7, Figure 8 and Figure 9 therefore provide a comparative assessment of the transient temperature evolution at two spatially separated sensing positions under resistive heating, radiative excitation, and multistage thermoelectric cooling. Because only two local temperature channels were employed for each subsystem, the results characterize the monitored positions and do not constitute a complete two-dimensional temperature map of the corresponding test surfaces.
Figure 7 presents the transient thermal response of the resistive heating subsystem based on ceramic PTC heaters. Both sensors positioned at opposite regions of the copper heat spreader exhibit similar temporal trends during heating. The progressive actuation and embedded PID regulation produced a smooth temperature evolution toward the investigated high-temperature condition, while the self-regulating electrical behavior of the ceramic PTC heaters also contributed to limiting abrupt changes in thermal excitation [16,17,18,33,34].
The temperature difference between the two channels provides a direct indication of the local thermal difference between the monitored positions. However, this two-point comparison should not be interpreted as a complete demonstration of spatial homogeneity over the entire 100 mm × 100 mm test surface. The measurements instead show that the two monitored regions followed comparable thermal trajectories under the investigated resistive-heating condition.
The thermal response obtained with the halogen irradiation subsystem is presented in Figure 8. In this configuration, the two 100 kΩ NTC thermistors were positioned at different locations within the irradiated region and directly monitored the local thermal response produced by the AR111 source. Because the lamp has a directional 24° beam and the experiment did not employ a radiometric spatial mapping system, the temperature difference between the two sensors cannot be converted into a quantitative spatial irradiance non-uniformity.
Nevertheless, the different responses observed at the two monitored positions are consistent with spatially dependent thermal excitation within the directional irradiation region. As established in Section 2.3 and Section 3.2, these measurements characterize local temperature responses and should not be interpreted as a measurement of radiative heat-flux distribution or as evidence of uniform irradiance across the complete test area. A quantitative determination of optical spatial non-uniformity would require dedicated radiometric measurements over the test plane, which were not performed in the present experimental campaign.
For sustained operation of the optical subsystem, the closed-loop temperature was limited to approximately 150 °C, as presented in Figure 11. This operating limit was adopted to avoid excessive thermal loading of the experimental assembly and temperature-sensitive components. The two monitored temperature channels exhibit stable controlled behavior under this operating condition, demonstrating the ability of the embedded control architecture to maintain the selected thermal operating level at the monitored locations.
Figure 11. Thermal response of the PID control system during continuous stabilization of the halogen heating subsystem limited to 150 °C.
The progressive PWM actuation strategy was also employed during startup of the halogen subsystem to reduce abrupt electrical loading associated with cold-start operation of the lamp. Together with the PID controller, this strategy provided progressive transition from startup to the controlled operating condition.
Figure 9 presents the transient thermal response of the multistage thermoelectric refrigeration architecture. Both miniature 10 kΩ NTC sensors positioned over the copper cold plate exhibit similar decreasing temperature trends as the refrigeration cascade is activated. Temperatures approaching −40 °C were observed under the investigated experimental configuration. As established in Section 2.3 and Section 3.3, this minimum temperature corresponds to the tested operating condition and should not be interpreted as a load-independent cooling specification.
At deep-cooling conditions, the transient behavior of the cascade is influenced by the thermal dynamics of the multistage assembly, including heat pumping, Joule heating, heat rejection, and thermal redistribution within the refrigeration structure [14,15,17]. The active liquid recirculation subsystem removes heat rejected by the thermoelectric stages during operation and is therefore an integral component of the demonstrated cooling architecture.
As in the heating experiments, the difference between the two cold-side temperature channels characterizes only the monitored positions on the copper plate. The similar temporal evolution of the two measurements indicates comparable thermal behavior at these positions, but the available two-point measurements are insufficient to establish a complete spatial temperature distribution over the 100 mm × 100 mm cold-side surface.
Overall, the results demonstrate stable controlled thermal operation at the monitored positions across the three investigated excitation modes: resistive heating, radiative heating, and multistage thermoelectric cooling. The embedded PID architecture provides controlled thermal actuation, while the paired temperature channels enable local comparison of the thermal response at spatially separated positions. The results should therefore be interpreted as evidence of thermal-control performance and local temperature consistency at the monitored positions, rather than as a complete quantitative demonstration of spatial thermal or irradiance homogeneity over the entire test area.

4.3. Experimental Limitations and Measurement Scope

The experimental results demonstrate the functional operation of the developed thermal excitation, refrigeration, sensing, control, and synchronized acquisition subsystems over the investigated operating conditions. However, several limitations must be considered when interpreting the measured thermal and electrical quantities, particularly because the present work focuses on platform development and functional demonstration rather than on complete metrological validation.
The hot-side thermal subsystem reached temperatures approaching 200 °C under resistive PTC excitation and approximately 170 °C under maximum AR111 radiative excitation. For sustained radiative operation, however, the controlled temperature was limited to approximately 150 °C to avoid excessive thermal loading of the experimental assembly and temperature-sensitive components. These experimentally observed peak temperatures and the adopted continuous operating limit should therefore be distinguished from a certified temperature operating range for all possible DUT configurations.
On the cold side, temperatures approaching −40 °C were obtained using the multistage thermoelectric refrigeration architecture combined with active liquid heat rejection. As discussed in Section 2.3 and Section 3.3, this value represents the minimum temperature observed under the investigated experimental configuration and is not a load-independent cooling specification. The achievable cold-side temperature depends on the thermal load imposed on the refrigeration cascade and on the corresponding heat-rejection conditions. A systematic determination of minimum cold-side temperature as a function of applied thermal load was not performed in the present experimental campaign.
During deep-cooling operation, condensation was observed on exposed metallic surfaces and thermal interfaces near the cold-side region. This effect becomes increasingly relevant as the surface temperature decreases below the ambient dew-point condition and can modify parasitic heat transfer and compromise electrical insulation during prolonged operation. Thermal insulation and environmental control should therefore be considered when the platform is operated for extended periods under deep subzero conditions [8].
Mechanical and thermal contact conditions constitute an additional source of measurement variability. The spring-loaded fixation mechanism described in Section 2.1 was designed to maintain contact between the DUT and the thermal interfaces while accommodating thermally induced dimensional changes. However, the applied contact force and corresponding interface pressure were not instrumented or independently quantified. Consequently, the influence of contact pressure on interface thermal resistance and run-to-run repeatability cannot be quantitatively separated from the present measurements. Although the same mechanical arrangement was maintained for the reported experimental procedure, this configuration consistency does not constitute quantitative control or measurement of contact pressure. Variations in thermal-interface-material thickness, sensor positioning, surface contact, and mechanical loading may contribute to differences between the externally measured temperatures and the actual temperatures at the active TEG interfaces [8].
The radiative excitation subsystem introduces a separate limitation. The AR111 halogen source provides directional localized radiative excitation but was not characterized as a standardized solar simulator. The two temperature sensors used during the radiative experiments provide local thermal measurements and do not constitute a spatial irradiance map. Spectral match, spatial irradiance non-uniformity, and temporal irradiance instability were not experimentally quantified using calibrated radiometric instrumentation. Consequently, the optical experiments should be interpreted as controlled radiative thermal excitation for STEG-oriented investigations rather than as reproduction of standardized solar irradiance conditions.
The temperature measurement channels were individually calibrated using the six-point procedure described in Section 2.5, resulting in a maximum observed calibration deviation within ±1% over the evaluated ranges. This value represents calibration performance and not the combined uncertainty of the complete measurement system. A complete propagated uncertainty budget was not established during the present experimental campaign. Such a budget would require quantitative treatment of additional contributions including the complete thermistor measurement chain, ADC-related effects beyond the reported acquisition resolution, sensor positioning and thermal coupling, DUT-to-interface thermal contact resistance and its dependence on the unquantified contact pressure, spatial temperature gradients, sensor dynamic response, and other systematic contributions relevant to the specific measurement configuration.
The temporal acquisition limitation must likewise be distinguished from digital synchronization performance. Timestamp alignment of the thermal and electrical data streams resulted in a residual digital synchronization skew below 50 ms. This value characterizes the alignment of the recorded data streams and does not represent the physical response time of the NTC thermistors. Sensor response is additionally affected by sensor construction, installation, thermal coupling, and the thermal mass of the measurement interface. These physical sensor time constants were not independently characterized in the present experimental campaign.
The electrothermal experiment presented in Section 4.1 also has a defined measurement scope. The electrical response was acquired under open-circuit conditions; therefore, the measured Voc does not by itself determine electrical output power. Electrical power delivered to a load would require simultaneous loaded voltage and current measurements, for which Pout = VI. Similarly, absolute thermoelectric conversion efficiency, defined as η = P out / Q ˙ h , requires measurement of the heat rate entering the hot side. Because Q ˙ h was not directly measured in the transient experiment, absolute TEG conversion efficiency is not reported.
These limitations define the appropriate interpretation of the experimental results. The present platform demonstrates controlled heating and cooling, localized radiative excitation, calibrated multichannel temperature acquisition, embedded closed-loop control, and timestamp-aligned transient electrothermal measurements. Quantities requiring direct heat-flow measurement, complete spatial mapping, calibrated contact pressure, sensor dynamic characterization, or a full propagated uncertainty budget remain outside the demonstrated measurement scope of the present configuration.

4.4. Functional Benchmarking and Methodological Positioning

To position the proposed system within representative thermoelectric characterization approaches, a functional benchmarking analysis was conducted using the studies summarized in Table 1 [9,10,11,12,13]. The comparison is intended to identify differences in experimental scope, thermal excitation, cooling capability, sensing, control, and acquisition architecture rather than to establish a universal ranking of metrological performance.
As established in Table 1, the compared studies address different experimental objectives. Some focus on conventional TEG characterization, thermoelectric materials, or efficiency-related measurements, whereas others discuss methodologies applicable to photovoltaic–thermoelectric configurations [9,10,11,12,13]. Consequently, parameters that are not explicitly reported in the corresponding studies are identified as not reported rather than estimated or inferred, and the absence of a reported characteristic should not be interpreted as evidence that the corresponding platform lacks that capability.
The approach represented by [9] provides a reference for experimental TEG characterization based on controlled thermal excitation and electrical measurement. Together with the acquisition and monitoring approach reported in [13], these earlier studies illustrate experimental arrangements specifically developed for conventional component-level TEG characterization. However, the information available for direct comparison does not provide a common quantitative basis for all indicators relevant to the present architecture. In particular, spatial thermal uniformity, settling time, repeated-run variability, and complete propagated measurement uncertainty are not consistently available across the compared studies. These quantities are therefore not used to claim superior performance of the proposed platform.
Cotfas et al. [10] differs from the other entries because it addresses photovoltaic–thermoelectric generation methodologies rather than a single characterization apparatus. It is retained in the comparison because it provides relevant context for coupled PV–TEG and STEG-oriented experimental configurations. Accordingly, the characteristics associated with [10] should be interpreted as representative of methodologies discussed in that work rather than as specifications of one experimental platform.
The approach represented by [11] provides a comparison for elevated-temperature thermoelectric investigation, with operation reported up to approximately 226.8 °C. This exceeds the nominal sustained hot-side limit adopted for the present platform, although temperatures approaching 200 °C were experimentally obtained with the resistive heating subsystem. The comparison illustrates the different design objectives of the systems: the proposed platform combines subzero active cooling, resistive and radiative excitation, embedded thermal control, and transient acquisition rather than focusing exclusively on maximum hot-side temperature.
Okawa et al. [12] is particularly relevant for distinguishing the present measurement scope from dedicated thermoelectric efficiency-measurement approaches. Heat-flow-related measurement capability is not implemented in the current platform configuration. Therefore, the proposed system does not provide direct heat-flow measurement or complete thermoelectric conversion-efficiency determination equivalent to an experimental arrangement specifically designed for that purpose. Its demonstrated scope instead comprises controlled thermal-boundary generation, calibrated temperature acquisition, open-circuit voltage measurement, and transient electrothermal observation.
The approach represented by [13] provides an additional reference for controlled thermoelectric experimentation, including operation at temperatures up to approximately 200 °C. The present work addresses a different experimental scope, emphasizing integration of hot- and cold-side conditioning, transient operation, embedded control, and TEG/STEG-oriented excitation within a common architecture. The present architecture combines an adopted sustained hot-side operating limit of approximately 150 °C, experimentally observed higher peak temperatures under the investigated excitation conditions, and active cold-side operation approaching −40 °C under the tested configuration. More importantly for the objective of this work, heating, refrigeration, sensing, embedded control, and electrothermal acquisition are integrated within the same experimental architecture.
For the proposed platform, the quantitative characteristics reported in Table 1 correspond to the experimental configuration demonstrated in this work. These include four individually calibrated NTC temperature channels acquired through a 12-bit ADC, dual PID thermal control updated at 10 Hz, open-circuit voltage acquisition using the UT61E+ instrumentation, and residual digital synchronization skew below 50 ms between the recorded thermal and electrical data streams. The maximum observed temperature-channel calibration deviation remained within approximately ±1% over the evaluated calibration points; as established previously, this value is a calibration-performance indicator rather than a complete propagated measurement uncertainty.
The comparison with established thermoelectric measurement routines also requires distinguishing the present transient procedure from methods intended to determine intrinsic material or module properties. Established approaches such as the Harman method use a specific electrical and thermal measurement sequence to derive thermoelectric parameters under defined boundary conditions. The transient procedure demonstrated in the present work was not implemented as a Harman measurement and should not be interpreted as one. Instead, the platform independently conditions the thermal boundaries and subsequently records the temporal relationship between the externally measured temperature difference and the open-circuit voltage during controlled thermal redistribution. Consequently, the present procedure demonstrates the platform’s capability for synchronized transient electrothermal observation rather than replacing established property-determination routines.
This distinction is particularly relevant to the apparent electrothermal ratio reported in Section 4.1. Because the hot- and cold-side temperatures were measured within the external copper structures rather than directly at the active TEG interfaces, the ratio Voc/ΔText was explicitly reported as an apparent system-level quantity rather than as an intrinsic Seebeck coefficient. Dedicated methods for intrinsic thermoelectric-property determination require boundary conditions, measurement locations, and uncertainty treatment appropriate to the corresponding property being evaluated.
Similarly, comparison with manufacturer data for a commercial TEG requires correspondence between the thermal-interface temperatures, mechanical contact conditions, electrical operating condition, and other boundary conditions used in the reference characterization and those reproduced experimentally. Because the present transient experiment employed externally located temperature sensors, unquantified contact pressure, and passive thermal redistribution following independently established initial conditions, it does not provide such a one-to-one reproduction. Manufacturer data therefore provide component-level reference information, whereas the results reported here characterize the response observed within the integrated experimental configuration.
Accordingly, the comparison in Table 1 should be interpreted as a functional and architectural benchmark. The principal contribution of the proposed platform is not the individual use of commercially available heating, cooling, sensing, or control components, but their coordinated integration within a common experimental environment. The system combines independently conditioned hot- and cold-side thermal structures, selectable resistive or radiative excitation, multistage thermoelectric cooling with active heat rejection, calibrated multichannel temperature sensing, embedded closed-loop control, and timestamp-aligned thermal and electrical acquisition.
This architecture enables programmable transient experiments in which thermal excitation, temperature evolution, and the corresponding thermoelectric open-circuit response can be monitored within the same experimental sequence. The methodological contribution therefore lies in the coordinated generation, control, and observation of transient thermal conditions and their associated electrical response rather than in claiming superior performance for any individual hardware element.
The proposed system is consequently positioned as a reconfigurable experimental infrastructure for TEG- and STEG-oriented investigations, while maintaining a common sensing, control, and acquisition framework. It is not intended to replace dedicated metrological thermoelectric-property measurement systems, heat-flow calorimetric arrangements, or standardized solar-simulator facilities.

5. Conclusions

This paper presented the development, implementation, and experimental demonstration of a hybrid thermoelectric characterization platform for controlled electrothermal investigations involving thermoelectric generators (TEGs) and STEG-oriented optical excitation. The proposed architecture integrates ceramic PTC heating, controlled halogen irradiation, multistage thermoelectric cooling, active liquid heat rejection, embedded PID-based thermal regulation, and synchronized multichannel data acquisition within a unified experimental infrastructure.
Under the investigated experimental conditions, the developed system reached cold-side temperatures approaching −40 °C, hot-side temperatures approaching 200 °C under resistive PTC excitation, and approximately 170 °C under maximum optical excitation. During sustained controlled optical operation, the hot-side temperature was limited to approximately 150 °C to avoid excessive thermal loading of the experimental assembly and temperature-sensitive components. These values represent the conditions observed for the tested configuration and should not be interpreted as load-independent operating specifications. The embedded architecture employed independent PID loops for the hot- and cold-side subsystems, with experimentally adjusted parameters and defined control and PWM frequencies, enabling controlled thermal operation under the investigated conditions.
The temperature measurement subsystem incorporated four independently calibrated NTC channels, with six-point calibration and individual adjustment of the measurement curve, offset, and β parameter. After calibration, the maximum observed deviation relative to the reference measurements remained within ±1% over the evaluated ranges. This value represents the observed calibration deviation and not a complete propagated measurement uncertainty. The thermal and electrical acquisition architecture also enabled timestamp-based post-processing alignment of transient measurements, with a residual digital synchronization skew below 50 ms. This value characterizes the digital time alignment and does not represent the physical response time of the temperature sensors, which was not independently characterized.
The transient TEG experiment demonstrated the temporally aligned evolution of the externally measured temperature difference and the generated open-circuit voltage. A maximum externally measured temperature difference of approximately 161.74 K was observed immediately before the transition to passive thermal relaxation, while a transient open-circuit voltage peak of 1.7818 V was subsequently recorded. Their ratio corresponds to an apparent system-level value of approximately 11.0 mV/K; however, this value should not be interpreted as the intrinsic Seebeck coefficient of the TEG because the temperatures were measured in the external copper thermal structures rather than directly at the active hot- and cold-side TEG junctions. The experiment therefore also illustrates the influence of the complete thermal path, including the spreaders and interfaces, on the temperature difference effectively established across the thermoelectric device. Accordingly, these transient system-level results should not be interpreted as a direct reproduction of manufacturer performance curves obtained under different prescribed interface and thermal-boundary conditions.
Overall, the results demonstrate the coordinated operation of controlled thermal excitation, multistage thermoelectric cooling, embedded thermal regulation, and synchronized electrothermal acquisition within a single experimental platform. The principal contribution of the work lies in this functional integration and in the ability to perform TEG/STEG-oriented experiments under resistive or radiative excitation, including controlled transient electrothermal measurements. The platform is therefore positioned as a reconfigurable experimental infrastructure rather than as a complete metrologically traceable thermoelectric characterization standard.
Several limitations define the scope of the present demonstration. The experiments did not include a complete propagated uncertainty budget, statistical repeatability assessment across multiple independent runs, calibrated spatial irradiance mapping of the optical source, calibrated measurement of the mechanical contact pressure, direct determination of interfacial thermal resistance, independent characterization of the physical temperature-sensor response times, direct heat-flow measurement, or systematic determination of the minimum cold-side temperature as a function of applied thermal load. Moreover, the open-circuit experiment does not provide electrical output power or absolute thermoelectric conversion efficiency because loaded voltage and current and the heat rate entering the TEG were not simultaneously measured. Because contact pressure was not instrumented, its influence on interface thermal resistance and run-to-run variability also could not be quantitatively isolated. These limitations should be considered when interpreting the reported results.
Future work should therefore address direct interface-temperature instrumentation, complete measurement-uncertainty quantification, statistical repeatability assessment, calibrated spatial irradiance and heat-flux measurements, controlled mechanical contact-force characterization, sensor dynamic-response characterization, and quantitative determination of cooling capacity under defined thermal loads. Reference benchmarking under matched thermal-boundary, interface, and mechanical-contact conditions could additionally support future metrological qualification of the platform without altering its present role as a reconfigurable experimental infrastructure. Electrical characterization under load through I–V and P–V measurements would additionally enable direct determination of output-power behavior, while simultaneous heat-flow measurements would be required for absolute thermoelectric conversion-efficiency assessment. Broader testing with different thermoelectric devices, automated thermal-profile generation, and advanced control strategies can further extend the experimental capabilities of the platform. The developed system thus provides a modular and scalable infrastructure for controlled investigation and further development of TEG- and STEG-oriented electrothermal experimental procedures and energy-harvesting systems.

Author Contributions

Conceptualization: E.A.d.S., J.J.G.L., M.R.C. and O.H.A.J.; methodology: E.A.d.S., J.J.G.L. and O.H.A.J.; validation: E.A.d.S., J.J.G.L., M.R.C. and O.H.A.J.; investigation and simulation: E.A.d.S. and O.H.A.J., writing—original draft preparation: E.A.d.S., J.J.G.L., M.R.C. and O.H.A.J.; writing—review and editing: E.A.d.S., J.J.G.L., M.R.C. and O.H.A.J.; project administration: O.H.A.J.; funding acquisition: M.R.C. and O.H.A.J. All authors have read and agreed to the published version of the manuscript.

Funding

This research was partially supported by the Brazilian National Council for Scientific and Technological Development (CNPq), grant numbers 407531/2018-1, 303293/2020-9, 405385/2022-6, 405350/2022-8 and 406662/2022-3.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

Data are not available for patent reasons.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Tritt, T.M. Thermoelectric phenomena, materials, and applications. Annu. Rev. Mater. Res. 2011, 41, 433–448. [Google Scholar] [CrossRef] [Scilit]
  2. Snyder, G.J.; Toberer, E.S. Complex thermoelectric materials. Nat. Mater. 2008, 7, 105–114. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Goldsmid, H.J. Introduction to Thermoelectricity; Springer: Berlin, Germany, 2010. [Google Scholar]
  4. Xiao, D. Thermoelectric generator design and characterization for industrial pipe waste heat recovery. Processes 2023, 11, 1714. [Google Scholar] [CrossRef] [Scilit]
  5. Kraemer, D. High-performance flat-panel solar thermoelectric generators with high thermal concentration. Nat. Mater. 2011, 10, 532–538. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Junior, O.H.A.; Calderon, N.H.; Souza, S.S. Characterization of a thermoelectric generator (TEG) system for waste heat recovery. Energies 2018, 11, 1555. [Google Scholar] [CrossRef] [Scilit]
  7. Soares, G.B.; Ledesma, J.J.G.; Silva, E.A.; Junior, O.H.A. Thermoelectric generators applied as a power source in CubeSats: State of the art. Energies 2025, 18, 173. [Google Scholar] [CrossRef] [Scilit]
  8. Ziolkowski, P. Heat flow measurement as a key to standardization of thermoelectric generator module metrology: A comparison of reference and absolute techniques. Measurement 2019, 135, 59–69. [Google Scholar]
  9. Izidoro, C.L.; Junior, O.H.A.; Carmo, J.P.; Schaeffer, L. Characterization of thermoelectric generator for energy harvesting. Measurement 2017, 106, 283–290. [Google Scholar] [CrossRef] [Scilit]
  10. Cotfas, P.A. Comprehensive review of methods and instruments for PV-TEG hybrid systems characterization. Energies 2020, 13, 6045. [Google Scholar] [CrossRef] [Scilit]
  11. Nguyen, K.T. An in-situ thermoelectric measurement apparatus inside a thermal-evaporator. Meas. Sci. Technol. 2023, 34, 095601. [Google Scholar] [CrossRef] [Scilit]
  12. Okawa, K. Quantitative comparison of heat flow, guarded-heater and AC Harman methods for thermoelectric module efficiency. arXiv 2026, arXiv:2605.11440. [Google Scholar]
  13. Junior, O.H.A.; Izidoro, C.L.; Gomes, J.M.; Correia, J.H.; Carmo, J.P.; Schaeffer, L. Acquisition and monitoring system for TEG characterization. Int. J. Distrib. Sens. Netw. 2015, 11, 531516. [Google Scholar] [CrossRef] [Scilit]
  14. T.T. Solutions. Multistage MS Series—High Temperature Differential Peltier Modules. Available online: https://tark-solutions.com/products/thermoelectric-cooler-modules/peltier-multistage-series (accessed on 10 June 2026).
  15. European Commission. Thermoelectric Cooling Using Innovative Multistage Active Systems; CORDIS Project Report, 2019. Available online: https://cordis.europa.eu/project/id/632436/reporting (accessed on 15 May 2026).
  16. Alter, D.M. Thermoelectric Cooler Control Using a TMS320F2812 DSP and a DRV592 Power Amplifier; Texas Instruments Application Report SPRA873; Texas Instruments: Dallas, TX, USA, 2003. [Google Scholar]
  17. Kherkhar, A. Thermal investigation of a thermoelectric cooler based on Arduino and PID control approach. Case Stud. Therm. Eng. 2022, 36, 102249. [Google Scholar] [CrossRef] [Scilit]
  18. Oliveira, M.B. Development of an adaptive PID control applied to thermoelectric cooling systems. In Proceedings of the ENCIT Conference; ABCM: Rio de Janeiro, Brazil, 2010; pp. 1–10. [Google Scholar]
  19. Espressif Systems. ESP32-WROOM-32 Datasheet, Version 3.6; Espressif Systems: Shanghai, China, 2021.
  20. Govind, S.M. Adapting the DEVS Kernel RT-CADMIUM to the ESP32 Embedded Platform. arXiv 2023, arXiv:2304.07961. [Google Scholar]
  21. Hasib, A. HydroSense: A Dual-Microcontroller IoT Framework for Real-Time Multi-Parameter Monitoring with Edge Processing and Cloud Analytics. arXiv 2026, arXiv:2601.21595. [Google Scholar]
  22. Hemalatha, H.R.J. IoT-Enabled Hemodynamic Surveillance System: AD8232 Bioelectric Signal Processing with ESP32. arXiv 2025, arXiv:2505.18173. Available online: https://arxiv.org/abs/2505.18173 (accessed on 15 May 2025).
  23. Infineon Technologies. BTS7960 High Current Half-Bridge Driver Datasheet; Infineon Technologies: Neubiberg, Germany, 2020. [Google Scholar]
  24. Silva, E.A. STEG-CUBE: Sistema Híbrido Solar-Termoelétrico para Energy Harvesting em CubeSat. Ph.D. Thesis, Universidade Federal da Integração Latino-Americana (UNILA), Foz do Iguaçu, Brazil, 2026. [Google Scholar]
  25. Junior, O.H.A.; Silva, E.A.; Lira, E.R.; Degiorgi, S.V.B.; Carmo, J.P.P. Comparative analysis and integrated methodology for the electrical design and performance evaluation of thermoelectric generators (TEGs) in energy harvesting applications. Energies 2024, 17, 5176. [Google Scholar] [CrossRef] [Scilit]
  26. Espejo, S.C.C.; Souza, S.S.; Junior, O.H.A. Development of a biochemical oxygen demand incubator prototype based on thermoelectric effect with monitoring system. IEEE Lat. Am. Trans. 2020, 18, 2037–2046. [Google Scholar] [CrossRef] [Scilit]
  27. Maran, A.L.O.; Martin, C.A.G.; Montes-Páez, E.; Junior, O.H.A. Modelling and simulation of a thermoelectric waste heat recovery system—TWRHS. DYNA 2021, 88, 265–272. [Google Scholar] [CrossRef] [Scilit]
  28. Calderón-Henao, N.; Venturini, O.J.; Franco, E.H.M.; Eduardo Silva Lora, E.; Scherer, H.F.; Maya, D.M.Y.; Ando Junior, O.H. Numerical–experimental performance assessment of a non-concentrating solar thermoelectric generator (STEG) operating in the Southern Hemisphere. Energies 2020, 13, 2666. [Google Scholar] [CrossRef] [Scilit]
  29. Amorim, M.L.M.; Junior, O.H.A.; Gazziro, M.; Carmo, J.P.P. Nexus: A modular open-source multichannel data logger—Architecture and proof of concept. Automation 2026, 7, 25. [Google Scholar] [CrossRef] [Scilit]
  30. Instituto Nacional da Propriedade Industrial—INPI. Software Registration BR512026002394; Instituto Nacional da Propriedade Industrial: Rio de Janeiro, Brazil, 2026.
  31. TT. Electronics. TEC1-12715 Thermoelectric Cooler Datasheet; Rev.; TT. Electronics: Woking, UK, 2022. [Google Scholar]
  32. Wellen Technology. TEC2-19008 Thermoelectric Cooling Module Specification; Shenzhen Wellen Technology Co., Ltd.: Shenzhen, China, 2022; Available online: https://www.wellentech.com/two-stage-modules/tec2-19008-thermoelectric-cooling-module.html (accessed on 15 May 2025).
  33. DigiKey. Introduction to PTC Heaters: Positive Temperature Coefficient Self-Regulating Electric Heaters; Application Note; DigiKey: Thief River Falls, MN, USA, 2020. [Google Scholar]
  34. Smith, J. Heating Performance Characteristics of High-Voltage PTC Heater for an Electric Vehicle. Energies 2018, 10, 1494. [Google Scholar] [CrossRef] [Scilit]
  35. Kraemer, L.R.; Maran, A.L.O.; Souza, S.S.; Junior, O.H.A. Analytical and numerical study for the determination of a thermoelectric generator’s internal resistance. Energies 2019, 12, 3053. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.