Skip to Content
Quantum ReportsQuantum Reports
  • Article
  • Open Access

17 February 2026

13 Pages

Enhancement of the Shift in the Photonic Spin Hall Effect and Its Application for Cancer Cell Detection

,
,
,
and
1
Department of Electronics Engineering, Institute of Engineering and Rural Technology, Prayagraj 211004, India
2
Department of Computer Science Engineering, Institute of Engineering and Rural Technology, Prayagraj 211004, India
3
Department of Electronics and Communication Engineering, Graphic Era Hill University, Dehradun 248002, India
4
Department of Electronics and Communication Engineering, Motilal Nehru National Institute of Technology Allahabad, Prayagraj 211004, India

Abstract

The photonic spin Hall effect (PSHE) originates from the spin–orbit interaction (SOI) of light. The literature indicates that the transverse spin-dependent shift, δ H − (SDS), from the PSHE is weak (in the nanometer range) and difficult to measure directly. This study utilizes a plasmonic structure to improve the δ H − in the PSHE. The obtained results of this study demonstrate that the inclusion of silicon nitride (Si3N4) significantly enhances the δ H − relative to its absence; however, plasmonic material is present in both cases. The enhanced shifts exhibit a significant dependence on the resonance angle ( θ r ) and the thickness of layers of the PSHE structure to attain the maximum increase in δ H − of 350.82 µm at the plasmonic resonance condition. A systematic analysis of the centroid positions of the reflected beam indicates a distinct and constant separation of opposing spin components. Further, the improved δ H − is utilized in cancer cell detection, as changes in the refractive index (RI) of cells facilitate the identification of cancer cells from healthy to cancerous. All examined cell types demonstrate that cancerous cells had a greater δ H − than normal cells, owing to their elevated effective RI. These results illustrate that the proposed plasmonic-assisted PSHE structure offers significant enhancement and a high sensitivity of 439.30 µm/RIU for label-free detection of cancer cells.

1. Introduction

Recently, the quantum science-based photonic spin Hall effect (PSHE) [1,2,3,4] has emerged as a powerful tool in the advancement of photonic devices for assessing the optical thickness of nanostructures [5] and determining the layer count of thin 2D materials [6], chiral metamaterials [7], and nano-metal films [8]. PSHE results from the spin–orbit interaction (SOI) of light, generating nanoscale transverse beam shifts. When linearly polarized light passes through an interface with a refractive index (RI) gradient, light splitting occurs into right-handed circular polarization (RCP) and left-handed circular polarization (LCP) [4,5,6]. This separation arises from the mutual interplay and interaction between the polarization and trajectory of the light beam. Onoda et al. first introduced this concept in 2004, illustrating that linearly polarized light experiences spin-dependent splitting, δ H − (SDS) into LCP and RCP components, which propagate perpendicular to the RI gradient during interaction with a multilayer structure with different RIs [9]. In 2006, Bliokh et al. provided a description of the transverse displacement of the PSHE based on electromagnetic field theory, incorporating the principle of the conservation of the total angular momentum of all photons. This provided the foundational theory for later investigations into the PSHE [10]. This theory fundamentally comprises two distinct geometric phases: the spin-redirection Ryto–Vladimirskii–Berry (RVB) phase, associated with changes in wave vector direction, and the Pancharatnam–Berry (PB) phase, related to changes in the polarization state of light. Hosten and Kwiat conducted the initial experimental demonstration of spin-dependent beam splitting at an air-glass interface in 2008 [11]. Researchers are presently utilizing the phenomenon of the PHSE to design different types of sensors. The various sensing applications have been documented in the scientific literature, including gas sensing [12,13], RI sensing [14], hemoglobin sensing [15], cancer cell detection [14], magnetic field detection [16], and air quality index (AQI) sensors [17]. It has been observed that the sensitivity of these sensors correlates with the δ H − present in the PHSE. This indicates that a larger δ H − results in greater sensor sensitivity.
The PSHE refers to a spin-dependent shift, δ H − (SDS), of light caused by SOI. This phenomenon can be utilized to detect minute changes in the RI [12,15] and to identify cancer cells without the use of labels. A key aspect of this process involves the separation of LCP and RCP light waves in different directions. This separation is highly sensitive to various physical factors [2]. However, the intrinsic PSHE is typically weak, resulting in δ H − values that range from the nanometer to several micrometers [2,7,9,13,18]. To enhance the δ H − , researchers utilize various techniques and materials, including weak measurement methods, the Brewster angle [19], surface plasmon resonance (SPR) [3], guided wave-based SPR [1,20], metamaterials [21], chiral materials [22], optical Tamm states (OTS) [23], and others [18] to advance extremely sensitive sensors and tunable photonic devices such as RI sensors [14], gas sensors [12], biosensors [14,15,20], magnetic field detection [16], image edge detection [24], etc. The optical vortex pair can also manipulate the amplitude and polarity of the PSHE, facilitating improved and tunable transverse δ H − without necessitating alterations to the material interface [25]. A 2024 study revisited the longitudinal δ H − process and elucidates the physical relationship between longitudinal δ H − and the Goos–Hänchen effect, resolving prior interpretative uncertainties [26]. These studies enhance the tunability of spatially varying δ H − by integrating both transverse and longitudinal δ H − into a cohesive framework based on the principles of angular momentum conservation. Despite these efforts, this δ H − still requires further enhancements for applications such as sensing and precision metrology.
The growing global burden of cancer underlines the urgent need for extremely sensitive and early-stage diagnostic methods. In contemporary times, lifestyle choices significantly influence the impact of cancer on human life. It is estimated that all types of cancer, including breast, blood, skin, adrenal gland, and cervical cancers, claimed the lives of 9.74 million people worldwide in 2022. The annual toll is expected to rise to 16.9 million by 2045 due to aging populations and environmental carcinogens. According to the latest global cancer death report, approximately 10.4 million individuals worldwide died from cancer in 2023, with 18.5 million new cases reported [27]. Breast and blood cancers remain the primary causes of cancer-related deaths globally (2022–2023), accounting for a substantial share of all cancer fatalities, while skin, adrenal gland, and cervical cancers account for relatively fewer occurrences. Breast cancer is one of the top five causes of cancer deaths around the world, accounting for about 6.9% of all cancer deaths [28]. Blood cancers, which include leukemia, lymphoma, and myeloma, account for about 6–7% of cancer deaths globally [29]. Cervical cancer is responsible for approximately 3.4% of all cancer-related deaths, with low- and middle-income countries bearing the majority of these cases [30]. Adrenal gland cancer is still very rare, making up less than 0.2% of all cancer deaths around the world. On the other hand, skin cancers, especially melanoma, make up more than 1% of all cancer deaths [31]. The literature indicates that the combined global impact of breast and blood cancers is significantly greater than that of other malignancies. Their detection is accomplished at an early stage through the usage of screening methods such as mammography, Pap tests, colonoscopy, and low-dose CT scans, which lead to satisfactory treatment results. However, these screening methods have the limitation that they can provide false positive or false negative results [32]. Therefore, it is necessary to use techniques that offer fast, accurate, non-invasive, and reliable cancer cell detection. In this direction, researchers proposed cancer cell detection using optical methods such as PSHE- and SPR-based sensing methods [14,20,33,34].
Based on the preceding discussion, it can be concluded that optical sensors are highly suitable for this challenge due to their capability for real-time detection, high sensitivity, compact design, and cost-effective operation without requiring elaborate sample preparation. Additionally, it has been observed that in optical SPR sensors utilized for cancer cell detection, cancer cells demonstrate a higher refractive index (RI) compared to normal cells, owing to the increased chromatin content within their larger nuclei. Therefore, the RI can be regarded as a vital parameter for differentiating between cancerous and normal cells [34].
The proposed PSHE structure in this work includes an SF10 glass prism, gold (Au), silicon nitride (Si3N4), molybdenum disulfide (MoS2), and an analyte. This study represents the first attempt to enhance the SDS amplitude using MoS2 and Si3N4. Additionally, we investigate a PSHE structure for the detection of cancer cells. To our knowledge, there are only a few works regarding the detection of cancer utilizing the PSHE. In this study, we propose an optical RI sensor based on the photonic SHE and explore new applications for the detection of cancer. The proposed sensor is capable of not only differentiating between normal human cells (including skin, cervical, breast, adrenal gland, and blood cells) and cancer cells but also distinguishing various concentrations of cancer cells. The results illustrate the enhanced sensing capabilities of this proposed PSHE structure, with a sensitivity of 439.30 μm/RIU, enabling effective discrimination between normal skin cells and cancerous cells.

2. Concept and PSHE Structure Design

2.1. PSHE Structure Design

To illustrate spin-dependent splitting (SDS) in a PSHE-based multilayer structure incorporating the Kretschmann configuration, a thin gold (Au) layer with optimized thickness (d2) is deposited onto an SF10 glass prism. Subsequently, a layer of silicon nitride (Si3N4) with an optimized thickness (d3) is deposited atop the gold, followed by molybdenum disulfide (MoS2) positioned on the Si3N4 with a thickness of d4 = 0.65 nm. The sensing medium is situated above the MoS2, as depicted in Figure 1a. In this figure, the PSHE of reflected light is represented. Here, θ i is the angle of incidence, d2 is the thickness of gold (Au), d3 is the thickness of Si3N4, and δ H − and δ H + are the transverse shifts of the RCP and LCP of reflected light. The incidence plane is xz, and the transverse shift is alongside the y-axis. The refractive indices (RIs) and thicknesses of all layers that make up the PSHE structure are shown in Table 1. The biomolecule solutions designed for both healthy and cancerous cells serve as a sensing medium to differentiate cancerous cells from healthy cells. The RI values for various cancer cell types and status are listed in Table 2. Gold serves as a plasmonic material that excites surface plasmons (SPs), which localize electromagnetic (EM) waves at the Au-dielectric interface. The excited SPs augment the spin–orbit interaction (SOI) of light, thereby amplifying the magnitude of the PSHE [1,4]. The SF10 prism is chosen for its high RI, which aids in effective momentum matching and enhances δ H − . Si3N4 is a high-RI material employed to reduce radiative losses and enhance the confinement of the evanescent field at the metal–dielectric interface [35]. Furthermore, the use of MoS2 is advantageous due to its direct bandgap, significant spin–orbit coupling, and larger light absorption [1,36]. Therefore, it interacts with light more strongly than conventional materials. This strong interaction modifies the refractive index variation gradient, which can effectively enhance the PSHE [1]. The Supplementary Materials (SM-1 and SM-2) [11,18,37,38,39,40,41,42,43,44,45,46,47,48,49,50,51] depict the potential experimental setup as well as possible deposition and characterization techniques for the proposed work.
Figure 1. (a) Systematic representation of the proposed PSHE multilayer structure when a beam is reflected from an interface. (b) Frontal aspect.
Table 1. RIs used in the proposed PSHE structure at a wavelength of 632.8 nm.
Table 2. RI data on cells in both healthy and cancerous states [34].

2.2. Concept and Working of PSHE Structure

When linearly polarized Gaussian light passes through an inhomogeneous optical interface with a RI gradient, the PSHE occurs due to the interplay between the light’s polarization and trajectory. This phenomenon arises from the spin–orbit interaction (SOI) of light, which causes the linearly polarized light to be separated into RCP and LCP light upon interacting with the interface. The photons of opposite spin states, which correspond to right- and left-circular polarization components, experience minute transverse spatial shifts. As illustrated in Figure 1, a monochromatic Gaussian light beam operating at a wavelength of 632.8 nm is incident on the proposed PSHE structure with a variation in the angle of incidence ( θ i ). As illustrated in Figure 1b, the coordinate frames ( x i , y i , z i ) and ( x r , y r , z r ) represent the incident and reflected coordinates, respectively. For the purposes of this discussion, we will assume that the beam, which exhibits a linear polarization state, is reflected from a planar interface. A laboratory coordinate system is defined such that the reflecting interface lies in the x y -plane, and the plane of incidence is the x z -plane. This means the y -axis is perpendicular to the plane in which the light beam is incident. Because the proposed structure has an RI gradient in the x z -plane, the LCP and RCP components of light experience slightly different optical paths when the beam interacts with the interface. This difference causes the two spin components to shift in opposite directions along the z-axis, i.e., out of the plane of incidence. This opposite displacement of spins is known as the PSHE. So, when linearly polarized light is incident on the prism–Au interface, whether by reflection or refraction, it can be decomposed into LCP and RCP components. Each experiences a different geometric phase due to the RI gradient, causing spin-dependent shifts (SDSs) perpendicular to the incident plane (i.e., along y ). These shifts are the observable signature of the PSHE in the device. It is generally agreed upon that the PSHE is the result of an effective SOI that describes the mutually beneficial effect of the trajectory and polarization of the light beam [1]. In studies by T. Tang et al. [52] and T. Srivastava et al. [53], the transverse SDS was determined utilizing a beam propagation model that incorporates angular spectrum theory. The transverse SDS ( δ H − ) can be written as follows:
δ H − = 1 k 0 1 + r s r p   c o s ( φ s − φ p )   c o t θ i
where k 0 is the free space wave vector, and r p ( r s ) and φ p ( φ s ) are the Fresnel reflection coefficients and the phase difference between the incident and reflected lights of p-polarized (s-polarized) light, respectively. Equation (1) presents the formula for calculating the mathematical amplification of the shift induced by the Fresnel reflection coefficients. It is crucial to understand that this shift is distinct from the physically measurable spatial displacement. The amplified shift outlined in Equation (1) arises from the rapid phase variation of the Fresnel coefficients at the resonance angle, which enhances the computed beam shift; however, it does not, by itself, indicate a spatial displacement. A measurable displacement occurs only after the convolution of the finite beam profile with the detector’s response [9,11].

2.3. Sensing Performance of PSHE Structure for Cancer Detection

The sensing performance of the PSHE structure is assessed through sensitivity ( S P S H E ) and a limit of detection ( L o D P S H E ). The sensitivity can be defined to assess the performance of the PSHE structure in detecting cancer cells as follows:
S P S H E = ∆ δ H − ∆ n s
where ∆ δ H − represents the difference in SDS between healthy and cancerous cells, while ∆ n s denotes the RI difference between these two types of cells. If the RI changes due to the attachment of cancerous molecules in the sensing medium, the change in ∆ n s is altered, resulting in a corresponding change in ∆ δ H − . The unit of S P S H E is µm/RIU.
The L o D P S H E is inversely proportional to the S P S H E and proportional to the smallest detectable δ H − shift during the actual experimental measurements [4]. It is defined as follows:
L o D P S H E = 0.001 o S P S H E
The unit of L o D s d is degrees RIU/µm. Furthermore, for sensing applications, it is essential that the sensor’s S P S H E be maximized, and that the magnitude of the L o D P S H E be minimized.

3. Results

3.1. Optimization of Layers Thickness in the PSHE Structure

To improve the SDS ( δ H − ), it is crucial to optimize the thickness of both Au (designated as d2) and Si3N4 (designated as d3) inside the PSHE structure. Figure 2a,b illustrate the ratio of r s r p alongside the maximum δ H − in relation to the thicknesses of Au and Si3N4. It is important to note that δ H − is proportional to the r s r p as indicated in Equation (1). This correlation is also illustrated in Figure 2, where both parameters demonstrate comparable tendencies, either increasing or decreasing concurrently as the thicknesses of Au and Si3N4 change. The peak δ H − value of 350.82 µm is achieved, corresponding to a maximum r s r p of approximately 3.2   × 10 7 at a resonance angle ( θ r ) of 57.524 degrees, with d2 measured at 44 nm and d3 at 1 nm. These maximum values are indicated by the green circle in Figure 2. Furthermore, this study utilized the optimized thicknesses of Au (d2) and Si3N4 (d3) to assess sensitivity.
Figure 2. Optimization of (a) r s r p and (b) δ H − with the thicknesses of Au and Si3N4.
To investigate the effect of Si3N4 thickness on the peak of δ H − , we varied the thicknesses of Si3N4, as shown in Figure 3a,b. In both figures, it is observed that the maximum δ H − is achieved at d3 of 1 nm because at this thickness of Si3N4, the ratio of r s r p is at its maximum due to r p being at its minimum, and the phase gradient of r p ( φ p ) is maximized. From Figure 3, it is also indicated that without the use of Si3N4, i.e., d3 = 0 nm, the maximum value of δ H − is only 9.10 µm. The enhancement of the δ H − induced by the introduction of the Si3N4 layer is not attributed to its crystal structure, as Si3N4 is optically isotropic and non-chiral in the wavelength range considered. Instead, the enhancement originates from interface-mediated SOI of light. The Si3N4 layer modifies the RI contrast and phase accumulation at the interface, leading to an increased gradient of the Fresnel reflection coefficients and an enhanced spin-dependent geometric (Pancharatnam–Berry) phase. These interfacial effects strengthen the transverse spin splitting characteristic of the PSHE. Prior research has extensively reported comparable enhancing mechanisms resulting from dielectric multilayers and interface engineering [2,8].
Figure 3. Impact of thicknesses of Si3N4 on δ H − (a) θ i vs. δ H − (b) d3 vs. δ H − .
Further, as the thickness increases, the δ H − is reduced because of the higher ohmic losses.
Figure 4 illustrates the out-of-plane spatial shift ( ∆ y ) as a function of the θ i to determine the beam centroid position. This spatial shift is calculated using the expression ∆ y   =   ∬ y r E r H 2 d x r d y r ∬ E r H 2 d x r d y r [24,37]. It is observed that the maximum centroid of 6.12   × 10 − 5 nm occurs at the θ r attributed to the maximum phase gradient with low intensity, and E r H 2 values for the RCP and LCP components are identical. At angles other than the θ r , the phase gradient changes, and E r H 2 values for the RCP and LCP components are not identical, so the result is a lower value of ∆ y in comparison to ∆ y at θ r = 57.524   degrees .
Figure 4. Beam centroid position shift with the θ i .
Finally, a comparison is made with the prism-based research on the PSHE to illustrate the enhancement in δ H − for the proposed PSHE structure. Table 3 provides a comparative analysis of the δ H − values achieved by different plasmonic PSHE structures. The obtained results indicate that the proposed PSHE structure attains a substantially higher δ H − compared to the current state of the art.
Table 3. Comparative study of PSHE with prism-based work.
The proposed PSHE structure is further analyzed in relation to its application as a refractive index (RI) sensor for cancer cell detection.

3.2. Sensing Performance of the PSHE Structure for Cancer Cell Detection

From Figure 5, it is evident that the peak of the δ H − is distinguishable across all types of cancer cells, showing a significant shift between healthy and cancerous cells. The RIs of biomolecule solutions for healthy and cancerous basal cells in skin cancer are 1.36 and 1.38, respectively. As illustrated in Figure 5a, the PSHE structure clearly shows the resonance angle shift and δ H − resulting from the presence of cancerous basal cells. The S P S H E and L o D P S H E are determined to be 439.30 µm/RIU and 2.28 × 10−6 deg. RIU/µm, respectively. Normal HeLa cells become cancerous after infection with human papillomavirus 18 (HPV18). In Figure 5b, the RIs of normal and cancerous HeLa cells are measured at 1.368 and 1.392, respectively. The sensing performance of the PSHE structure for cancerous HeLa cells yields an S P S H E of 322.02 µm/RIU and a L o D P S H E of 3.10 × 10−6 deg. RIU/µm. In Figure 5c, the δ H − response as a function of the incident light angle is examined for normal and Jurkat cell recognition using the PSHE structure. The S P S H E and L o D P S H E for this configuration are found to be 149.78 µm/RIU and 6.68 × 10−6 deg. RIU/µm, respectively. For adrenal gland cancer, breast (MDA-MB-231) cancer, and breast (MCF-7) cancer, the S P S H E values are 118.68 µm/RIU, 102.82 µm/RIU, and 91.49 µm/RIU, with L o D P S H E values of 8.43 × 10−6 deg. RIU/µm, 9.73 × 10−6 deg. RIU/µm, and 10.90 × 10−6 deg. RIU/µm, respectively. These results indicate that the proposed biosensor has a high capability to detect subtle refractive index changes between normal and cancerous basal cells, demonstrating significant sensitivity. Additionally, a comparative analysis of all proposed configurations is presented in Table 4.
Figure 5. The δ H − response curves for six cancer cells to be used to examine S P S H E and L o D P S H E for (a) skin, (b) cervical, (c) blood, (d) adrenal gland (PC-12), (e) breast (MDA-MB-231), and (f) breast (MCF-7) cancer.
Table 4. The sensing performance of the proposed PSHE structure for cancerous cells with respect to normal cells.
Finally, Table 5 provides a comparative study of the proposed work with previously reported results. This analysis emphasizes the superiority of the present research due to its substantially enhanced sensitivity.
Table 5. Comparative analysis of sensitivity for the proposed PSHE structures with reported PSHE-based cancer cell detection.

4. Conclusions

In this work, first, the enhancement of the spin-dependent shift ( δ H − ) using a multilayer structure is proposed. The multilayer structure is optimized in such a way as to achieve the resonance condition to improve the PSHE. The maximized δ H − of 350.82 µm is achieved due to the combined SPR waveguiding effect, which is much higher than reported in the literature. In the second part of the study, the enhanced δ H − is utilized to detect cancerous cells. This sensitivity is achieved with minimal RI variations between healthy and cancerous cells. The PSHE structure showed a substantial incident angle shift in the PSHE resonance between healthy and cancerous blood cells. The maximum sensitivity of 439.30 µm/RIU is attained for the skin cell. These findings collectively underscore the significant potential of PSHE-based sensing for biomedical applications, especially in accurately differentiating between diverse healthy and cancerous blood cells. This capability may facilitate the creation of sophisticated diagnostic photonics devices specifically designed for cancer detection and monitoring. Further, the authors believe that the proposed work also has potential future applications, such as secure encoding and encryption [57], and hardware-level security systems [58]. The proposed work can be further enhanced by integrating it with compact on-chip photonic platforms. This integration would allow for its application within the wider framework of ongoing developments in PSHE-based sensing, security, and information processing, ultimately strengthening the overall impact and future prospects of the study.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/quantum8010017/s1, Figure S1: The schematic representation illustrates the experimental setup for measuring PSHE.

Author Contributions

Conceptualization, A.V. and Y.K.P.; methodology, A.V. and Y.K.P.; software, A.V., D.K. and Y.K.P.; validation, A.V., D.K. and Y.K.P.; formal analysis, A.V. and Y.K.P.; investigation, A.V. and Y.K.P.; resources, A.V., Y.K.P. and V.M.; data curation, A.V.; writing—original draft preparation, A.V., D.K. and Y.K.P.; writing—review and editing, A.V., Y.K.P., V.M. and R.G.; supervision, A.V. and Y.K.P. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding authors.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Xiang, Y.; Jiang, X.; You, Q.; Guo, J.; Dai, X. Enhanced spin Hall effect of reflected light with guided-wave surface plasmon resonance. Photonics Res. 2017, 5, 467–472. [Google Scholar]
  2. Li, H.; Jia, Q.; Shi, B.; Zhou, Y.; Cao, Y.; Luan, K.; Wang, D.; Zhu, T.; Shi, Y.; Tang, D.; et al. Large Optical Lateral Force with a Phase-Engineered Photonic Spin Hall Effect. ACS Photonics 2025, 12, 3337–3343. [Google Scholar] [CrossRef] [Scilit]
  3. Zeng, Z.; Liang, J.; Guo, L.; Deng, D.; Wang, G.; Zhang, L.; Liang, C. Manipulating photonic spin Hall split based on nonlinear effect and surface plasmon resonance. Opt. Commun. 2024, 572, 130949. [Google Scholar] [CrossRef] [Scilit]
  4. Kumar, V.; Maurya, J.B.; Prajapati, Y.K. Piezoplasmonic System for Enhanced Photonic Spin Hall Effect for Applications in Optical Refractive Index Sensing. IEEE J. Sel. Top. Quantum Electron. 2025, 31, 1–9. [Google Scholar] [CrossRef] [Scilit]
  5. Ling, X.; Zhou, X.; Luo, H.; Wen, S. Steering far-field spin dependent splitting of light by inhomogeneous anisotropic media. Phys. Rev. A 2012, 86, 053821. [Google Scholar] [CrossRef] [Scilit]
  6. Zhou, X.; Ling, X.; Luo, H.; Wen, S. Identifying graphene layers via spin Hall effect of light. Appl. Phys. Lett. 2012, 101, 251602. [Google Scholar] [CrossRef] [Scilit]
  7. Wang, H.; Zhang, X. Unusual spin Hall effect of a light beam in chiral metamaterials. Phys. Rev. A 2011, 83, 053820. [Google Scholar] [CrossRef] [Scilit]
  8. Olaya, C.M.; Hayazawa, N.; Balgos, M.H.; Tanaka, T. Enhancing angular photonic spin Hall effect at surface plasmon resonance. Nanophotonics 2025, 14, 3115–3124. [Google Scholar] [CrossRef] [Scilit]
  9. Onoda, M.; Murakami, S.; Nagaosa, N. Hall effect of light. Phys. Rev. Lett. 2004, 93, 083901. [Google Scholar] [CrossRef] [Scilit]
  10. Bliokh, K.Y.; Bliokh, Y.P. Conservation of angular momentum, transverse shift, and spin Hall effect in reflection and refraction of an electromagnetic wave packet. Phys. Rev. Lett. 2006, 96, 073903. [Google Scholar] [CrossRef] [Scilit]
  11. Hosten, O.; Kwiat, P. Observation of the spin Hall effect of light via weak measurements. Science 2008, 319, 787–790. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Kumar, V.; Srivastava, R.; Prajapati, Y.K. Improved Photonic Spin Hall Effect by an Induced Polarization Gradient in Anisotropy-Black Phosphorous and Its Application to NO2 Gas Detection. IEEE Sens. J. 2023, 23, 20976–20983. [Google Scholar] [CrossRef] [Scilit]
  13. Yang, W.; Ang, L.K.; Zhang, W.; Han, J.; Xu, Y. High sensitivity gas sensor based on surface exciton polariton enhanced photonic spin Hall effect. Opt. Express 2023, 31, 27041–27053. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Cheng, J.; Xiang, Y.; Xu, J.; Liu, S.; Dong, P. Highly sensitive refractive index sensing based on photonic spin Hall effect and its application on cancer detection. IEEE Sens. J. 2022, 22, 12754–12760. [Google Scholar] [CrossRef] [Scilit]
  15. Ahlawat, L.; Kishor, K.; Sinha, R.K. Photonic spin Hall effect-based ultra-sensitive refractive index sensor for haemoglobin sensing applications. Opt. Laser Technol. 2024, 170, 110183. [Google Scholar] [CrossRef] [Scilit]
  16. Pandey, S.; Shukla, H.; Mishra, V.; Pal, S.; Prajapati, Y.K.; Verma, A. Highly Sensitive Magneto-Optical SPR Sensor Based on the Photonic Spin Hall Effect with CeYIG and Graphene. IEEE Trans. Magn. 2026, 62, 4000409. [Google Scholar] [CrossRef] [Scilit]
  17. Ahlawat, L.; Kishor, K.; Baitha, M.N.; Sinha, R.K. Photonic Spin Hall Effect-Based AQI Sensor: Effect of Concentration of PM2.5. IEEE Sens. J. 2025, 25, 14589–14597. [Google Scholar] [CrossRef] [Scilit]
  18. Liu, S.; Chen, S.; Wen, S.; Luo, H. Photonic spin Hall effect: Fundamentals and emergent applications. Opto-Electron. Sci. 2022, 1, 220007. [Google Scholar] [CrossRef] [Scilit]
  19. Ma, Z.; Lai, Z.; Lin, S.; Hong, J.; Chen, Y.; Zhou, X. Generalized Brewster angle enhanced photonic spin Hall effect in an all-dielectric metasurface. Opt. Lett. 2023, 48, 3003–3006. [Google Scholar] [CrossRef] [Scilit]
  20. Kim, Y.; Baitha, M.N.; Chun, H.-J.; Kim, K. High-sensitivity cancer cell detection with dual-polarization photonic spin Hall effect. Opt. Laser Technol. 2025, 189, 113174. [Google Scholar] [CrossRef] [Scilit]
  21. Ling, X.; Zhou, X.; Yi, X.; Shu, W.; Liu, Y.; Chen, S.; Luo, H.; Wen, S.; Fan, D. Giant photonic spin Hall effect in momentum space in a structured metamaterial with spatially varying birefringence. Light. Sci. Appl. 2015, 4, e290. [Google Scholar] [CrossRef] [Scilit]
  22. Zhou, Q.; Tan, Y.; Sheng, L.; Cao, Y.; Wang, Z.; Ling, X. Chirality-induced tunable quasi-Brewster angle and anomalous photonic spin-Hall effect. Opt. Laser Technol. 2025, 187, 112811. [Google Scholar] [CrossRef] [Scilit]
  23. Tang, J.; Zhang, Y.; Yuan, H.; Long, X.; Jiang, J.; Tian, H.; Jiang, L. Enhanced and tunable photonic spin Hall effect with optical Tamm states. J. Appl. Phys. 2023, 134, 233102. [Google Scholar] [CrossRef] [Scilit]
  24. Zhu, T.; Lou, Y.; Zhou, Y.; Zhang, J.; Huang, J.; Li, Y.; Luo, H.; Wen, S.; Zhu, S.; Gong, Q.; et al. Generalized spatial differentiation from the spin hall effect of light and its application in image processing of edge detection. Phys. Rev. Appl. 2019, 11, 034043. [Google Scholar] [CrossRef] [Scilit]
  25. Zhen, W.; Wang, X.-L.; Ding, J.; Wang, H.-T. Controlling the symmetry of the photonic spin Hall effect by an optical vortex pair. Phys. Rev. A 2023, 108, 023514. [Google Scholar] [CrossRef] [Scilit]
  26. Zhen, W.; Wang, X.L.; Ding, J.; Wang, H.T. Revisiting physical mechanism of longitudinal photonic spin splitting and Goos-Hänchen shift. New J. Phys. 2024, 26, 013045. [Google Scholar] [CrossRef] [Scilit]
  27. Filho, A.M.; Laversanne, M.; Ferlay, J.; Colombet, M.; Piñeros, M.; Znaor, A.; Parkin, D.M.; Soerjomataram, I.; Bray, F. The GLOBOCAN 2022 cancer estimates: Data sources, methods, and a snapshot of the cancer burden worldwide. Int. J. Cancer 2025, 156, 1336–1346. [Google Scholar] [CrossRef] [Scilit]
  28. Al-Hajj, M.; Wicha, M.S.; Benito-Hernandez, A.; Morrison, S.J.; Clarke, M.F. Prospective identification of tumorigenic breast cancer cells. Proc. Natl. Acad. Sci. USA 2003, 100, 3983–3988. [Google Scholar] [CrossRef] [Scilit]
  29. Jang, S.J.; Gardner, J.M.; Ro, J.Y. Diagnostic approach and prognostic factors of cancers. Adv. Anat. Pathol. 2011, 18, 165–172. [Google Scholar] [CrossRef] [Scilit]
  30. Hakim, R.U.; Amin, T.; Islam, S.M.B.U. Advances and challenges in cervical cancer: From molecular mechanisms and global epidemiology to innovative therapies and prevention strategies. Cancer Control. 2025, 32, 10732748251336415. [Google Scholar] [CrossRef] [Scilit]
  31. Nissan, N.; Albiztegui, R.E.O.; Fruchtman-Brot, H.; Gluskin, J.; Arita, Y.; Amir, T.; Reiner, J.S.; Feigin, K.; Mango, V.L.; Jochelson, M.S.; et al. Extremely dense breasts: A comprehensive review of increased cancer risk and supplementary screening methods. Eur. J. Radiol. 2025, 182, 111837. [Google Scholar] [CrossRef] [Scilit]
  32. Macios, A.; Nowakowski, A. False negative results in cervical cancer screening—Risks, reasons and implications for clinical practice and public health. Diagnostics 2022, 12, 1508. [Google Scholar] [CrossRef] [Scilit]
  33. Alsaad, A.M.; Al-Hmoud, M.; Marashdeh, M.W.; Aljaafreh, M.J.; Rababah, T.M. Design and modeling of a novel highly sensitive surface plasmon resonance sensor applying tin selenide and graphene for cancer detection. Plasmonics 2024, 19, 2061–2069. [Google Scholar] [CrossRef] [Scilit]
  34. Mostufa, S.; Akib, T.B.A.; Rana, M.; Islam, R. Islam, highly sensitive TiO2/Au/graphene layer-based surface plasmon resonance biosensor for cancer detection. Biosensors 2022, 12, 603. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  35. Yesudasu, V.; Srivastava, R.; Pal, S.; Verma, A.; Prajapati, Y.K. Numerical analysis of an advanced surface plasmon resonance biosensor utilizing nitride material-tungsten ditelluride-black phosphorus. Phys. B Condens. Matter 2023, 675, 415619. [Google Scholar] [CrossRef] [Scilit]
  36. Wang, Q.; Jiang, X.; Wang, X.; Dai, X.; Xiang, Y. Enhancing photonic spin Hall effect in the surface plasmon resonance structure covered by the graphene–MoS2 heterostructure. IEEE Photonics J. 2017, 9, 1–10. [Google Scholar] [CrossRef] [Scilit]
  37. Luo, H.; Zhou, X.; Shu, W.; Wen, S.; Fan, D. Enhanced and switchable spin Hall effect of light near the Brewster angle on reflection. Phys. Rev. A. 2011, 84, 043806. [Google Scholar] [CrossRef] [Scilit]
  38. Bliokh, K.Y.; Alonso, M.A.; Ostrovskaya, E.A.; Aiello, A. Angular momenta and spin-orbit interaction of nonparaxial light in free space. Phys. Rev. A. 2010, 82, 063825. [Google Scholar] [CrossRef] [Scilit]
  39. Lin, S.; Hong, J.; Chen, Z.; Chen, Y.; Zhou, X. Optimal weak measurement in the photonic spin Hall effect for arbitrary linear polarization incidence. Optics Express 2022, 30, 4096–4105. [Google Scholar] [CrossRef] [Scilit]
  40. Homola, J. Surface Plasmon Resonance Sensors; Springer: Berlin/Heidelberg, Germany, 2006. [Google Scholar]
  41. Chopra, K.L. Thin Film Phenomena; McGraw-Hill: New York, NY, USA, 1969. [Google Scholar]
  42. Smith, D.L. Thin-Film Deposition: Principles and Practice; McGraw-Hill: New York, NY, USA, 1995. [Google Scholar]
  43. George, S.M. Atomic Layer Deposition: An Overview. Chem. Rev. 2010, 110, 111–131. [Google Scholar] [CrossRef] [Scilit]
  44. Elam, J.W.; Zinovev, A.V.V.; Pellin, M.J.; Comstock, D.J.; Hersam, M.C. Nucleation and growth of ALD films on noble metals. J. Vac. Sci. Technol. A 2003, 21, 1099–1107. [Google Scholar]
  45. Meng, X.; Byun, Y.C.; Kim, H.S.; Lee, J.S.; Lucero, A.T.; Cheng, L.; Kim, J. Atomic layer deposition of silicon nitride thin films: A review of recent progress, challenges, and outlooks. Materials 2016, 9, 1007. [Google Scholar]
  46. Powell, C.J.; Jablonski, A. Surface sensitivity of X-ray photoelectron spectroscopy. J. Electron. Spectrosc. Relat. Phenom. 2010, 178–179, 331–346. [Google Scholar] [CrossRef] [Scilit]
  47. Wang, Q.H.; Kalantar-Zadeh, K.; Kis, A.; Coleman, J.N.; Strano, M.S. Electronics and optoelectronics of two-dimensional transition metal dichalcogenides. Chem. Soc. Rev. 2015, 44, 2664–2680. [Google Scholar] [CrossRef] [Scilit]
  48. Najmaei, S.; Liu, Z.; Zhou, W.; Zou, X.; Shi, G.; Lei, S.; Yakobson, B.I.; Idrobo, J.-C.; Ajayan, P.M.; Lou, J. Vapour phase growth and grain boundary structure of MoS2 atomic layers. Nature Mater. 2013, 12, 754–759. [Google Scholar] [CrossRef] [Scilit]
  49. Garcia, R.; Perez, R. Dynamic atomic force microscopy methods. Surf. Sci. Rep. 2002, 47, 197–301. [Google Scholar] [CrossRef] [Scilit]
  50. Tompkins, H.G.; Irene, E.A. Handbook of Ellipsometry; William Andrew Publishing: Norwich, NY, USA, 2005. [Google Scholar]
  51. Moulder, J.F.; Stickle, W.F.; Sobol, P.E.; Bomben, K.D. Handbook of X-Ray Photoelectron Spectroscopy; Perkin-Elmer: Shelton, CT, USA, 1992. [Google Scholar]
  52. Tang, T.; Li, C.; Luo, L. Enhanced spin Hall effect of tunneling light in hyperbolic metamaterial waveguide. Sci. Rep. 2016, 6, 30762. [Google Scholar] [CrossRef] [Scilit]
  53. Srivastava, T.; Chitriv, S.; Sahu, S.; Gorai, P.; Jha, R. Photonic spin Hall effect using hybrid Tamm plasmon polariton. J. Appl. Phys. 2022, 132, 203103. [Google Scholar] [CrossRef] [Scilit]
  54. Zhou, X.; Ling, X. Enhanced Photonic Spin Hall Effect Due to Surface Plasmon Resonance. IEEE Photonics J. 2016, 8, 1–8. [Google Scholar] [CrossRef] [Scilit]
  55. Srivastava, A.; Sharma, A.K.; Prajapati, Y.K. On the sensitivity-enhancement in plasmonic biosensor with photonic Spin Hall effect at visible wavelength. Chem. Phys. Lett. 2021, 774, 138613. [Google Scholar] [CrossRef] [Scilit]
  56. Sahu, S.; Srivastava, T.; Jha, R. Plexcitonic system for high photonic spin Hall effect. Appl. Phys. Lett. 2023, 123, 203302. [Google Scholar] [CrossRef] [Scilit]
  57. Pei, N.; Zheng, Y.; Tang, Y.-Q.; Tang, X.-Z.; Zhang, H.-F. Theoretical investigation of photonic spin Hall effect based on layered metastructure with graphene regulation by WOA for encoding and encryption. Mater. Des. 2025, 255, 114218. [Google Scholar] [CrossRef] [Scilit]
  58. Divyanshu, D.; Goyal, A.K.; Massoud, Y. Physical unclonable function using photonic spin Hall effect. Sci. Rep. 2024, 14, 14393. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.