Sample Integrity in Respiratory Virus Surveillance: A Study on Volume Loss in Collection Kits at a Public Health Laboratory †

,
,
,
,
,
,
and
1
Programa de Residência Multiprofissional em Vigilância em Saúde, Núcleo de Epidemiologia e Vigilância em Saúde, Fundação Oswaldo Cruz, Brasília 70.904-130, Brazil
2
Laboratório Central de Saúde Pública do DF (Lacen/DF), Subsecretaria de Vigilância à Saúde (SVS), Secretaria de Estado de Saúde do DF (SES/DF), Brasília 70.830-010, Brazil
3
Escola de Saúde Pública do Distrito Federal (ESP-DF), Fundação de Ensino e Pesquisa em Ciências da Saúde, Brasília 70.710-100, Brazil
*
Author to whom correspondence should be addressed.
Introduction: Sample integrity is a critical factor for the reliability of molecular testing in public health laboratories, especially for epidemiological surveillance data. Inconsistent transport media volume and variations in swab quantity are common pre-analytical challenges that impact the quality and reproducibility of diagnostic results. This study investigated the impact of saline absorption by swabs and the variation in swab numbers, seeking evidence for the standardization and improvement of collection protocols in an active surveillance scenario. Methodology: For this study, six standardized collection kits were used. The initial volume was measured, and the swabs were inserted into the tubes for 24 h. After immersion, the remaining volume was transferred to a microtube and measured again, allowing us to quantify the solution loss. Additionally, we evaluated the impact of the number of swabs (one to three) on molecular test performance. Results: The analysis demonstrated a 37% average loss of the initial saline solution volume, with absorption by the swabs being the primary factor. A maximum variation of 51% in volume loss was observed in one of the kits. This significant volume reduction and the variation in the number of swabs (1 to 3) did not directly impact the molecular test results. Conclusions: The reduction in sample volume due to liquid absorption by swabs is an underestimated pre-analytical factor that can compromise the sensitivity and quality of molecular diagnostics. This study highlights the urgent need to standardize collection materials to ensure the reliability of surveillance data, which is essential for public health decision-making.

Author Contributions

Conceptualization, F.C.M.; methodology, F.C.M.; validation, F.B.L., F.C.M. and F.G.d.O.A.Y.; formal analysis, F.C.M.; investigation, F.C.M.; data curation, E.H.d.P.; writing—original draft preparation, F.C.M.; writing—review and editing, E.H.d.P.; visualization, L.A.A.S.; writing—review, T.P.C.; project administration, E.H.d.P. supervision; F.J.Q.C. and G.A.d.S.; review. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

Data are available in this manuscript.

Conflicts of Interest

The authors declare no conflict of interest.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.