Thermodynamic Investigation of a Novel Hybrid Carnot Battery with Thermal Storage at Two Temperature Levels

Department of Mechanical Engineering, School of Engineering, University of West Attica, 250 Thivon & Petrou Ralli, 12244 Athens, Greece

Abstract

Energy storage is a critical step for the decarbonization of our society by exploiting renewable energies. Carnot batteries are promising technologies for storing excess electricity from renewables, but their efficiency is generally limited. The present work suggests a novel idea for enhancing the performance and flexibility of Carnot battery units. Specifically, a hybrid system that exploits both electricity and waste heat streams is suggested, incorporating two stages of latent thermal storage to increase flexibility. Moreover, the present system uses an innovative cascade high-temperature heat pump, with an absorption heat transformer in the low stage and a vapor-compression unit in the upper stage. The power production machine is a recuperative organic Rankine cycle. Practically, the absorption heat transformer exploits the waste heat stream by upgrading it and reducing the temperature lift that the vapor-compression heat pump produces, so there is increased electrical performance with suitable consumption of the waste heat stream. Also, the respective configuration without the absorption heat transformer is studied to make a suitable comparison. The results of this analysis show that the adoption of the AHT enhances the roundtrip efficiency from 26.30% up to 92.31% (relative enhancement) compared to the system without it. For the main scenario with a waste heat stream temperature at 100 °C, the roundtrip efficiency was found to be 72.86% and the exergetic efficiency as 35.02% for the system with the absorption heat transformer.

1. Introduction

The increasing penetration of renewable energies in the electrical grid makes energy storage an essential element for balancing electricity demand and production with grid stability [1] and for limiting the loss of available renewable-produced electricity [2]. This issue is becoming increasingly important in Europe, where renewable generation reached 47% of the electricity mix in 2024, while the occurrence of negative electricity prices has increased considerably, indicating periods of excess generation and insufficient system flexibility [3]. In Greece, this challenge is already evident, since about 528 GWh of renewable electricity was curtailed only during the first seven months of 2024, corresponding to approximately 3.5% of renewable production [4]. Although electrochemical batteries can effectively provide short-term flexibility, their large-scale deployment is associated with issues related to cost, lifetime, safety, and dependence on critical materials, such as lithium, cobalt, nickel, and graphite [5]. Thermal management is also an important aspect of battery operation, and recent studies have investigated advanced cooling configurations, including radial divergent coolant channels and liquid cooling plates with non-uniform spiral fins, to improve heat transfer and temperature uniformity [6,7]. Thermal energy storage represents an interesting alternative, especially for large-scale applications, due to the possibility of using relatively inexpensive storage media and operating over long storage periods [8]. At the same time, thermal storage can facilitate the utilization of waste heat, which remains a largely underexploited energy source. Specifically, the yearly technically available waste heat potential is estimated to be 300 TWh within the European Union [9]. Within this framework, Carnot batteries constitute a very promising option because they convert excess electricity into thermal energy during charging, store it in thermal form, and subsequently convert it back into electricity when required [10]. Their ability to combine electrical and thermal energy flows, together with the possibility of integrating waste heat, makes them particularly attractive for future energy systems with high renewable penetration [11]. Usually, Carnot batteries are based on the use of Rankine or Brayton cycles [12]. They can be designed for various capacities from 100 kW to 100 MW or more [13] while also incorporating sensible or latent thermal storage [14]. Moreover, Carnot batteries can be exploited in polygeneration systems for producing multiple useful outputs (e.g., electricity, heating, and cooling).
In the literature, there have been several investigations that have examined the application of Carnot batteries for storing excess electricity from renewables. Steger et al. [15] studied an ambient-source Carnot battery that used the R1233zd(E) working medium with sensible water storage, and the storage temperature was studied in the range of 90 to 120 °C. The roundtrip efficiency was found to be 59%, and, in this case, the organic Rankine cycle (ORC)’s thermodynamic efficiency was 10.2%, and the heat pump (HP)’s coefficient of performance (COP) was 5.8. Frate et al. [16] investigated a Carnot battery with sensible storage and cyclopentane working fluid. They found that the roundtrip efficiency was 55% and the storage density was 15 kWh/m3. Eppinger et al. [17] conducted a detailed analysis of a Carnot battery with latent storage, and they concluded that the roundtrip efficiency ranged from 56% to 61%. In critical benchmark work by Dumont and Lemort [18], it was concluded that the classical architectures of Carnot batteries can reach up to 60% power-to-power efficiency, while advanced architectures and the exploitation of waste heat streams (WHSs) can increase this index. In this direction, McTigue et al. [19] investigated a recuperative Joule–Brayton configuration as a Carnot battery unit that can reach up to 72% roundtrip efficiency, proving that advanced configurations can be efficient.
The utilization of energy sources provides an important exergy input in the unit, such as in the evaporator of the HP, as a way to improve the roundtrip efficiency and develop suitable designs [20]. Henchoz et al. [21] examined a system that was driven by an ambient source and solar thermal collectors. They found that the roundtrip efficiency can reach up to 65%, which is a satisfying value. Bellos et al. [22] examined a solar-driven unit that uses a recuperative heat pump and an ORC with cyclopentane as the working medium, while latent storage is applied. They found the roundtrip efficiency to be 68% and the payback period to be 7.8 years in the optimal design. The application of concentrating parabolic trough solar collectors on a Carnot battery system has been studied by Yu et al. [23]. This idea makes it possible for the exploitation of heat input in the HP at greater temperatures and thus store thermal energy at higher temperature levels. The results of this work showed a roundtrip efficiency of 63% with solar-only operation, which is an important improvement compared to the system without solar collectors.
Moreover, other important ideas have been studied in the literature. Yang et al. [24] studied a Carnot battery coupled to an absorption chiller that also produced cold energy. They optimized the waste heat streams in order to exploit these properly. They found the exergy efficiency of the unit to be up to 37% and the roundtrip efficiency up to 73%. Lykas et al. [25] studied a polygeneration Carnot battery that covered the loads of a building regarding electricity, heating, and cooling. The results proved a gross roundtrip efficiency of 82%, which covers 87% of the building’s loads on average. Bellos [26] examined a novel design of a Carnot battery with latent storage that utilized a WHS optimally. The WHS was exploited in two ways, first by providing heat directly to the storage unit and then by feeding the heat pump. It was found that the roundtrip efficiency was 64%, and the exergy efficiency was close to 37%.
As indicated by the existing literature, a lot of research has been devoted to Carnot batteries, aiming to maximize their performance and to incorporate renewable and alternative energy sources into them. In this direction, this paper suggests a novel Carnot battery unit that incorporates two latent thermal storage systems, which is a key innovative feature as it increases the flexibility of the system, providing the opportunity to store energy from electricity and waste heat streams at different time periods. An additional innovative aspect is the high-temperature heat pump, which is a cascade unit that includes an absorption heat transformer in the lower stage (AHT) and a vapor-compression heat pump in the upper stage. The power thermodynamic cycle is a recuperative ORC. The existence of the AHT upgrades the WHS and enables the efficient operation of the HP with a high COP. It is useful to state that the unit is compared with a respective system without the AHT but with double storage systems. The analysis is thermodynamic and aims to calculate the energetic and exergetic performance of the unit for various design conditions. The simulation is performed in Engineering Equation Solver [27] through a verified model. The analysis focuses on identifying the conditions that maximize the thermodynamic performance of the proposed configuration.

2. Materials and Methods

2.1. The Studied Configurations

In the present work, two Carnot battery systems are investigated, and their characteristic is thermal energy storage in two different latent systems. This idea permits storing energy at two different temperatures, increasing their flexibility and making possible the optimal utilization of the WHS that feeds the unit. In this analysis, the electricity input in the heat pump is assumed to be 1000 kW, while the WHS comprises flue gases with temperature levels at 80–100–120 °C. The mass flow rate of the flue gases is not restricted, assuming that there is always adequate waste energy for boosting the system performance. The WHS leaves the system with a 20 K lower temperature level, assuming that there is no problem with the minimum outlet temperature level. The latent storage is constructed with phase change materials (PCMs), which change phase at a constant temperature (a reasonable assumption), and these systems always store energy in the latent phase. Also, the maximum limit of the high pressure in the HP and ORC devices is selected at 90% of the critical pressure, which is a reasonable assumption.
The first examined system is depicted in Figure 1, and it is a novel one that includes AHT, HP, ORC, and two storage units. The AHT is driven by the WHS, and it practically upgrades the thermal input, which is stored in the low-stage PCM unit, and feeds the evaporator of the HP. The HP includes an internal heat exchanger (IHX) and exploits excess electricity to further the thermal input. After the upgrade, heat is released from the heat pump condenser to the high-stage PCM, where it is stored. When there is a need for electricity, the stored thermal energy in the high-stage PCM is given to the ORC for electricity production. The second examined system, which is depicted in Figure 2, is practically the benchmark scenario that is similar to the first one in Figure 1, but it does not include the AHT. This system includes both latent thermal storage units, the HP, and the ORC. As such, there is a double-stage heat upgrade in the AHT-HP-ORC system where, practically, the heat pump is a cascade one, with the AHT as the low-stage subsystem and the mechanical vapor-compression HP in the high-stage system. This idea is very interesting in high-temperature heat pumps, and it has been recently suggested by Bellos [28].
Figure 1. The novel Carnot battery, including AHT, HTHP, ORC, and two latent storage units (System-1).
Figure 2. The baseline Carnot battery, including HTHP, ORC, and two latent storage units (System-2).
Regarding the devices used, a small description would be beneficial for understanding their operational principles. The AHT operates with the LiBr/H2O working pair, which receives heat input in the generator and in the evaporator. The absorbed heat is upgraded, and it is released from the absorber by the low-stage latent storage unit. This storage unit stores the heat and feeds the HP when there is available excess electricity for performing further heat upgrades. The HP is a single-stage cycle with an IHX, and operates with cyclopentane as the working fluid. The upgraded heat from the HP is stored in the high-stage latent storage system. When there is electricity demand, the stored thermal energy in the high-stage storage device is provided to the heat recovery system (HRS) of the ORC for electricity production. The ORC is a cycle with a recuperator that operates using cyclopentane as the working medium. The selection of cyclopentane is a suitable choice for efficient operation according to the literature [15,29].

2.2. Mathematical Formulation

2.2.1. Absorption Heat Transformer Modeling

The WHS provides thermal input to the system via two devices, namely the evaporator and the generator. It is assumed that both devices operate at equal temperature levels [30], and the heat input is produced by the WHS in parallel. The following equations describe the respective energy equilibria:
Qwhs = mwhs ⋅ cp,whs ⋅ (Twhs,in − Twhs,out)
Qwhs = Qwhs,1 + Qwhs,2
The (mwhs) is the total mass flow rate of the WHS that feeds both devices. Also, the separate energy balances are:
Qwhs,1 = Qe,AHT
Qwhs,2 = Qg,AHT
The energy balance and the mass flow rate balance for the total mass and for the LiBr in the absorber are listed below:
Qa = mr ⋅ h4 + ms ⋅ h10 − mw ⋅ h5
mw = mstr + mr
mw ⋅ Xw = mstr ⋅ Xstr
The energy balances for the evaporator, condenser, generator, and solution heat exchanger are provided in the following equations:
Qe = mr ⋅ (h4 − h3)
Qc = mr ⋅ (h1 − h2)
Qg = mr ⋅ h1 + ms ⋅ h8 − mw ⋅ h7
Qhex = ms ⋅ (h10 − h9) = mw ⋅ (h5 − h6)
The effectiveness of the solution heat exchanger is given below, and it is selected at 70% [31]:
η hex = T 10 − T 9 T 5 − T 9
The process in the throttling valve is an ideal one, and according to the first thermodynamic law, it can be written as:
h7 = h6
In the AHT, the pumping work is extremely low in both pumps compared to the heat transfer quantities in the main devices, and consequently gives [30]:
h3 = h2
h9 = h8

2.2.2. Heat Pump Modeling

The thermal input in the HP from the low-stage storage unit is provided to the evaporator:
Qe,HP = mHP ⋅ (ha − hf)
The electricity input to the compressor is given below:
P el , in = m HP ⋅ ( h c − h b ) η motor , C
The compressor’s isentropic efficiency is presented below, using the isentropic point “c,is”:
η is , c = h c , is − h b h c − h b
The useful heat production from the HP to the high-stage storage system is:
Qc,HP = mHP ⋅ (hc − hd)
The energy equilibrium in the IHX is written as:
QIHX = mHP ⋅ (hb − ha) = mHP ⋅ (hd − he)
The temperature difference in the hot side of the IHX was set at ΔTIHX = 5 K [24]:
ΔΤΙHΧ = Td − Tb
The process in the throttling valve is an ideal one, and according to the first thermodynamic law, it can be written:
he = hf
In the HP, there is no superheating at the evaporator outlet and no subcooling at the condenser outlet [22].

2.2.3. Organic Rankine Cycle Modeling

The thermal input in the HRS of the ORC from the high-stage storage unit is:
Qhrs,orc = morc ⋅ (h4,orc − h3,orc)
In this analysis, no superheating is selected at the outlet of the HRS to minimize the exergy destruction during the heat transfer [22].
The heat discharged to the environment through the condenser is written as:
Qc,orc = morc ⋅ (h6,orc − h1,orc)
The electricity produced by the electrical generator is written as:
PG = ηmg ⋅ morc ⋅ (h4,orc − h5,orc)
The electricity consumed by the motor that drives the pump is given as:
P P = m orc ⋅ h 2 , orc − h 1 , orc η motor , P
The net electricity output by the ORC is calculated as:
Pel,out = PG − PP
The expander’s isentropic efficiency is presented below, using the isentropic point “5,orc,is”:
η is , T = h 4 , orc − h 5 , orc h 4 , orc − h 5 , orc , is
The pump’s isentropic efficiency is presented below, using the isentropic point “2,orc,is”:
η is , P = h 2 , orc , is − h 1 h 2 , orc − h 1 , orc
The energy equilibrium in the recuperator is:
Qrec = morc ⋅ (h3,orc − h2,orc) = morc ⋅ (h5,orc − h6,orc)
The temperature difference in the cold side of the recuperator is set at ΔTrec = 5 K [24]:
ΔTrec = T6,orc − T2,orc

2.2.4. Storage System Modeling

Low-stage storage system for AHT-HP-ORC:
The energy equilibrium in the low-stage latent storage system is written as follows:
Qa,AHT = Qe,HP + Qloss,low
The storage efficiency in the low-stage latent storage system is given as [26]:
η st , low = Q e , HP Q a , AHT
Low-stage storage system for HP-ORC:
The energy equilibrium in the low-stage latent storage system is written as follows:
Qwhs = Qe,HP + Qloss,low
The storage efficiency in the low-stage latent storage system is given as [26]:
η st , low = Q e , HP Q whs
High-stage storage for both systems (AHT-HP-ORC and HP-ORC):
The energy equilibrium in the high-stage latent storage system is written as follows:
Qc,HP = Qhrs,orc + Qloss,high
The storage efficiency in the high-stage latent storage system is given as [26]:
η st , high = Q hrs , orc Q c , HP
It is assumed that the phase change is conducted at a constant temperature level, and that there is only latent storage and no sensible storage [26].

2.2.5. Evaluation Indices of the System

The COP of the AHT is defined below, neglecting the pumping work demand [30]:
CO P AHT = Q a , AHT Q e , AHT + Q g , AHT
The COP of the HP is calculated as follows:
CO P HP = Q c , HP P el , in
The ORC thermal efficiency is calculated as follows:
η th , orc = P el , out Q hrs , orc
The power-to-power (or roundtrip) efficiency of the total unit is calculated as:
η P 2 P = P el , out P el , in
The exergy efficiency of the unit is calculated as:
η ex = P el , out P el , in + E x whs
In this investigation, the exploited WHS exergy rate is used. Specifically:
E x whs = Q whs − m whs ⋅ c p , whs ⋅ T 0 ⋅ ln T whs , in T whs , out
where the reference temperature is T0 = 298.15 K.

2.3. Followed Methodology

In this analysis, the studied configurations are simulated using developed codes in Engineering Equation Solver [27]. The investigation is conducted in steady-state conditions, assuming that there is latent storage in both storage units. The electricity input is equal to 1000 kW in all cases for the HTHP, and this is an assumption made by this analysis. Typical values for the turbomachinery, the heat exchanger design, and the remaining parameters are selected, and these are summarized in Table 1, where the respective references are also provided. It is important to note that vapor-compression high-temperature heat pumps (HTHPs) delivering heat at temperatures close to or above 200 °C require specialized system designs to address challenges associated with lubricant thermal stability, refrigerant–lubricant compatibility, material durability, component temperature limits, and the high operating pressures and discharge temperatures that may arise under such demanding conditions.
The developed models for the AHT, HTHP, and ORC have also been used in previous studies by the author, and their verification evidence is provided in these previous studies. Specifically, the verification of the AHT model was provided in Ref. [30] by using data from Ref. [31], while the HTHP-ORC system has been verified in Ref. [22] by using data from Ref. [29]. Therefore, there is no specific reason for presenting the verification processes again. Regarding the thermophysical properties of LiBr/water, the proper libraries of the tool were used, which are based on the data of Ref. [32].
During the present work, the temperature of the WHS varies from 80 to 120 °C with a step of 20 °C. The high-stage temperature of the PCM is studied parametrically for both configurations, while the low-stage temperature of the PCM is also studied parametrically but only for the AHT-HP-ORC. For the HP-ORC system, the low-stage temperature of the PCM is fixed, and it is dependent on the WHS temperature at the outlet and pinch point. This work is theoretical, and the PCM melting temperature is studied parametrically. However, there are real PCMs that can support the studied temperature-level demand, such as solar salt (NaNO3–KNO3), LiNO3–NaCl, and nitrate-based eutectics. Moreover, an optimization process for the optimum design of the AHT-HP-ORC system is conducted to maximize the exergy efficiency (objective function). In the optimization analysis, the PCM temperature levels of both stages are the optimization variables. For the cases with a single optimization variable, the “Golden Section Search Method” is applied; when there are two optimization variables, the “Conjugate Directions Method” is applied. Both optimization methods are supported by the tool used; 1000 iterations were selected for the maximum limit, and the convergence criterion was set at 10−8.
Table 1. Main boundary conditions of the analysis.

3. Results and Discussion

3.1. Performance of the Separate Devices

The present section presents the results regarding the performance of the separately examined devices in order to show how the variations in critical design parameters influences them. Figure 3 illustrates the AHT COP variation for different values of the low-stage PCM temperature level, as well as for three different WHS temperature levels. For the three studied WHS temperatures (Twhs,in = 80–100–120 °C), the three curves have a similar pattern; up to one temperature level, the COP is around 0.5, after which it has a dramatic reduction with the Tpcm,low increase. This fact indicates that for every Twhs,in, there is a window of Tpcm,low values in which the system has a relatively constant performance. Also, it is worthwhile to state that for higher Twhs,in values, the system can operate at higher values of Tpcm,low. Practically, the present results show that the system can keep relatively satisfying COP values for a proper range of Tpcm,low, but after a certain limit, the gross temperature lift of the AHT increases, and there is no possibility for efficient heat upgrade.
Figure 3. AHT performance for different combinations of low-stage PCM and WHS temperatures.
Figure 4 shows the COP of the heat pump for different values of Tpcm,low and Tpcm,high. The COP takes values from around 2 to 10, which is an extremely large range; this indicates that the operating conditions have a strong influence on the HP’s performance. It is obvious that the rise in Tpcm,low leads to a greater COP, while the rise in Tpcm,high leads to a smaller COP. Practically, the HP has a lower performance when it operates with a greater temperature lift, which can be defined as Tpcm,high minus Tpcm,low. The greater temperature lift means that the machine has to make a higher heat upgrade, which reduces the performance margin. It is critical to state that, in the framework of this analysis, the Tpcm,low did not reach very high values where the highest COP values were reported. Practically, it reached up to 150 °C depending on the Tpcm,high value.
Figure 4. COP of the HP for different combinations of low- and high-stage PCM temperature levels.
Figure 5 presents the ORC’s thermodynamic efficiency for various operating scenarios. The critical parameter for this index is the Tpcm,high, which ranges from 140 up to 220 °C, while the results are given for three condenser temperatures of 30, 35, and 40 °C. It was found that the rise in the condenser temperature decreases the thermodynamic efficiency, which is a reasonable outcome. In this work, the main analysis was performed using the condenser temperature of 30 °C. For this scenario, the ORC’s efficiency ranged from 17.00% for Tpcm,high = 140 °C to 22.97% for Tpcm,high = 220 °C.
Figure 5. ORC’s thermodynamic efficiency for different combinations of the high-stage PCM and condenser temperatures.

3.2. Parametric Analysis for WHS Temperature at 100 °C

The performance results of the AHT-HP-ORC system with Twhs,in = 100 °C are presented in this section. The results are given for various combinations of Tpcm,low and Tpcm,high temperature levels. The Tpcm,low ranges from 80 to 115 °C and the Tpcm,high from 140 to 220 °C.
Figure 6 illustrates the roundtrip efficiency of the unit for the scenarios studied. According to the results, this index increases with the rise in the Tpcm,low and decreases with the rise in the Tpcm,high. There are some scenarios where this index takes values over 100%, and it is justified by the exploitation of the WHS, which provides an exergy input to the system. This valuable outcome proves that the suitable utilization of waste heat streams in Carnot battery units makes the sustainable design with high performance and high electricity production values possible. Indicatively, for Tpcm,high = 140 °C, the roundtrip efficiency ranged from 66.16% to 134.40%; for Tpcm,high = 180 °C, the roundtrip efficiency ranged from 53.41% to 77.93%; and for Tpcm,high = 220 °C, the roundtrip efficiency ranged from 43.46% to 54.91%.
Figure 6. Power-to-power efficiency of the AHT-HP-ORC system with Twhs,in = 100 °C.
The exergy efficiency of the total unit is presented in Figure 7. This index accounts for the contribution of the exploited waste heat stream to the overall system performance, and it ranged from approximately 30% to 35%. The depicted curves present the maximum exergy efficiency for Tpcm,low = 110 °C, which indicates that this temperature level is the ideal one. This result can be explained by the performance of the AHT, which is depicted in Figure 3. For the case of Twhs,in = 100 °C, the COP of the AHT starts to dramatically reduce after the temperature level of Tpcm,low = 110 °C, and this fact means that the overall system exergy efficiency is maximized for this temperature level. Regarding the impact of Tpcm,high on the exergy performance, it was found that the exergy efficiency is maximized for Tpcm,high = 180 °C, and this is the ideal value for the high-stage PCM temperature. Therefore, the reported maximum exergy efficiency is 35.01% for Tpcm,low = 110 °C–Tpcm,high = 180 °C, according to the parametric analysis with Twhs,in = 100 °C.
Figure 7. Exergy efficiency of the AHT-HP-ORC system with Twhs,in = 100 °C.
In the next part of this section, the values of electricity production are given in Figure 8. The presented results have the same trends as the roundtrip efficiency of Figure 6 because, in this paper, the electricity input is 1000 kW in all the scenarios. The produced power increases with the increase in Tpcm,low and the decrease in Tpcm,high. Indicatively, for Tpcm,high = 140 °C, the roundtrip efficiency ranged from 661.6 kW to 1344 kW; for Tpcm,high = 180 °C, the roundtrip efficiency ranged from 534.1 kW to 779.3 kW; and for Tpcm,high = 220 °C, the roundtrip efficiency ranged from 434.6 kW to 549.1 kW.
Figure 8. Net power production by the ORC of the AHT-HP-ORC system with Twhs,in = 100 °C.
The last figure of this analysis is Figure 9, where the WHS thermal input in the system is given. This thermal input is provided to the AHT to be upgraded. The depicted results have a similar trend to the reported results for the produced power in Figure 8. Practically, the increase in the WHS demand leads to a rise in the electricity production as the extra WHS energy is converted into electricity through the studied unit. The demand for WHS increases with the rise in Tpcm,low and the decrease in Tpcm,high. Indicatively, for Tpcm,high = 140 °C, the roundtrip efficiency ranged from 6677 kW to 17,092 kW; for Tpcm,high = 180 °C, the roundtrip efficiency ranged from 3747 kW to 7005 kW; and for Tpcm,high = 220 °C, the roundtrip efficiency ranged from 2211 kW to 3646 kW. The reported results show that for high Tpcm,low, the demand was higher, as well as for low Tpcm,high. In cases with high HT COP, the demand for heat input from the WHS was higher because the electricity input was constant; this note can explain the reported results in Figure 9.
Figure 9. Waste heat stream input in the AHT-HP-ORC system with Twhs,in = 100 °C.

3.3. Comparison of the Two Carnot Battery Systems for WHS Temperature at 100 °C

The performances of the AHT-HP-ORC (System-1) and the HP-ORC (System-2) systems with Twhs,in = 100 °C are included in this section. The comparison is conducted for different values of the Tpcm,high in the range from 140 to 220 °C. Regarding the values of the Tpcm,low, it is optimized for System-1 to maximize the system exergy efficiency, while it is fixed for System-2 due to the pinch point constraints. Specifically, it is 75 °C for System-2 because the WHS has a 100 °C temperature at the inlet; it loses 20 K in the heat exchanger, and there is also a pinch point of 5 K, as has been clearly explained in Section 2.
The electricity production of the ORC is depicted in Figure 10. System-1 (AHT-HP-ORC) produced significantly higher amounts of electricity than System-2 (HP-ORC). Power production decreased with the increase in Tpcm,high for both systems. The power production enhancement for System-1 was greater at lower Tpcm,high values. Specifically, it was 92.31% for Tpcm,high = 140 °C and 26.30% for Tpcm,high = 220 °C. Also, the power production variation for System-1 ranged from 1186 kW for Tpcm,high = 140 °C to 533.6 kW for Tpcm,high = 220 °C, while for System-2, this ranged from 616.7 kW for Tpcm,high = 140 °C to 422.5 kW for Tpcm,high = 220 °C.
Figure 10. Net power production by the ORC for both Carnot battery systems with Twhs,in = 100 °C, and further optimized Tpcm,low for the AHT-HP-ORC system.
The WHS demand for the unit operation is illustrated in Figure 11. The results prove that System-1 has a significantly greater demand for WHS to drive the unit. Specifically, the WHS demand for System-1 ranged from 14,086 kW for Tpcm,high = 140 °C to 3318 kW for Tpcm,high = 220 °C, while for System-2, it ranged from 3018 kW for Tpcm,high = 140 °C to 1038 kW for Tpcm,high = 220 °C. The significantly higher WHS demand for System-1 is justified by the increased COP of the HP due to the heat upgrade by the AHT (see Figure 12). This fact leads to a higher heat input demand of the HP due to the boundary condition of the constant electricity input at 1000 kW in all the scenarios. The increased WHS demand for System-1 practically means a higher exergy input in the system, and thus, this system is able to produce higher electricity output.
Figure 11. Waste heat stream input for both Carnot battery systems with Twhs,in = 100 °C, and further optimized Tpcm,low for the AHT-HP-ORC system.
Figure 12. Heat pump’s COPs for both Carnot battery systems with Twhs,in = 100 °C, and further optimized Tpcm,low for the AHT-HP-ORC system.
As was previously mentioned, the COP of HP was significantly higher in System-1 compared to System-2, as Figure 12 indicates. The COP for System-1 ranged from 7.34 for Tpcm,high = 140 °C to 2.45 for Tpcm,high = 220 °C, while for System-2, it ranged from 3.82 for Tpcm,high = 140 °C to 1.94 for Tpcm,high = 220 °C. COP enhancement ranged from 92.27% for Tpcm,high = 140 °C to 26.29% for Tpcm,high = 220 °C. At this point, it is critical to mention that the reason for the higher COP in System-1 was the existence of the AHT, which upgraded the WHS. The COP of the AHT was approximately constant for the optimum conditions, close to the value of 0.47, while the optimal value of Tpcm,low was around 111 °C.
The next part of this section is devoted to the basic performance index indicators. The power-to-power efficiency is depicted in Figure 13 for both systems. System-1 outperformed, presenting high roundtrip efficiency values in the range from 118.60% for Tpcm,high = 140 °C to 53.36% for Tpcm,high = 220 °C, while System-2 presented efficiency values from 61.67% for Tpcm,high = 140 °C to 42.25% for Tpcm,high = 220 °C. The results show significant performance enhancements with the application of the AHT in System-1, leading to an enhancement of 92.31% for Tpcm,high = 140 °C to 26.30% for Tpcm,high = 220 °C. Also, it is useful to note that the performance of System-1 was significantly affected by variations in Tpcm,high, while the variation for System-2 was more restricted.
Figure 13. Power-to-power efficiency for both Carnot battery systems with Twhs,in = 100 °C, and further optimized Tpcm,low for the AHT-HP-ORC system.
The other index studied is the exergy efficiency of the total unit, and the respective results are represented in Figure 14. Exergy efficiency is affected by the electricity input and output rates, as well as by the consumption of the WHS. The results show that System-2 had higher exergy efficiency than System-1, while System-1 produced more electricity. This outcome resulted from the higher demand for WHS in System-1, which led to a greater exergy addition in the unit. The exergy efficiency of System-2 decreased with the increase in Tpcm,high; specifically, it was at its maximum at 40.05% for Tpcm,high = 140 °C and its minimum at 35.64% for Tpcm,high = 220 °C. The exergy efficiency of System-1 was maximized at 35.02% for Tpcm,high = 180 °C, while it was 33.70% for Tpcm,high = 140 °C and 33.49% for Tpcm,high = 220 °C. The difference between the exergy efficiency of both scenarios was not huge, and it ranged from 18.83% for Tpcm,high = 140 °C to 6.42% for Tpcm,high = 220 °C.
Figure 14. Exergy efficiency for both Carnot battery systems with Twhs,in = 100 °C, and further optimized Tpcm,low for the AHT-HP-ORC system.

3.4. Performance for Different WHS Temperatures and Discussion

The last part of Section 3 is devoted to comparing the results of both systems for different WHS temperatures and further discussing them. The present results have an optimal value for the Tpcm,low for System-1. Figure 15 shows the power-to-power efficiency for Twhs,in = 80–100–120 °C for both systems. The results are given for different Tpcm,high in the range from 140 to 220 °C. For the cases of Twhs,in = 120 °C, Tpcm,high ranged from 160 to 220 °C because, for lower values, there was not enough space for thermal storage in two different temperature levels. The results show that the rise in Tpcm,high reduced the power-to-power efficiency for all cases. Also, System-1 was always more efficient than System-2. The performance enhancement was higher in lower Tpcm,high values.
Figure 15. Power-to-power efficiency for both Carnot battery systems for various Twhs,in values and further optimized Tpcm,low for the AHT-HP-ORC system.
The exergy efficiency of the studied scenarios with Twhs,in = 80–100–120 °C is depicted in Figure 16. System-2 presented a higher exergetic performance for all the cases, and the exergy efficiency had a decreasing rate with the growth of Tpcm,high. On the other hand, the curves of the exergy efficiency for System-1 presented a maximum performance. For Twhs,in = 80 and 100 °C, the optimal Tpcm,high was 180 °C, while for Twhs,in = 120 °C, this was 190 °C.
Figure 16. Exergy efficiency for both Carnot battery systems for various Twhs,in values and further optimized Tpcm,low for the AHT-HP-ORC system.
It is interesting to comment that both roundtrip efficiency and exergy efficiency presented higher values when the WHS was warmer. This is an interesting result, which indicates that the warmer the WHS, the higher the performance achieved. Also, this is a reasonable outcome, because the input of a higher exergy rate into the system through the WHS affords a higher ability for top performance. Table 2 includes the results for the parametric investigation of System-1 with different WHS temperatures.
Table 2. Summary of the results for the AHT-HP-ORC system, with optimized Tpcm,low and different Twhs,in (optimized parameter: Tpcm,low).
The last part of this analysis is the optimization of System-1 for the various WHS temperatures. The optimization variables are the two PCM temperatures, and the goal is the maximization of the exergy efficiency. The optimization results are reported in Table 3. The results show that for Twhs,in = 80 °C, the optimal Tpcm,low was 72.5 °C, the optimal Tpcm,high was 178.7 °C, the electricity production was 503.8 kW, the roundtrip efficiency was 50.38%, and the system exergy efficiency was 34.18%. For Twhs,in = 100 °C, the optimal Tpcm,low was 110.8 °C, the optimal Tpcm,high was 181.5 °C, the electricity production was 728.6 kW, the roundtrip efficiency was 72.86%, and the system exergy efficiency was 35.02%. For Twhs,in = 120 °C, the optimal Tpcm,low was 150 °C, the optimal Tpcm,high is 187.7 °C, the electricity production was 1254 kW, the roundtrip efficiency was 125.40%, and the system exergy efficiency was 35.36%.
Table 3. Optimal design of the AHT-HP-ORC system for different Twhs,in (optimized parameters: Tpcm,low and Tpcm,high).
It is interesting to note that the rise in the WHS temperature significantly increases the optimal low-stage PCM temperature, while the optimal high-stage PCM temperature presents a small increase. Also, the increase in the WHS temperature leads to a significant enhancement of power production and of the roundtrip efficiency, while the exergy efficiency presents a marginal enhancement. Practically, a warmer WHS can lead to higher power production, but higher amounts of the WHS are required; so, the power-to-power efficiency index that values only the electricity flows is enhanced a lot, while the exergy efficiency that also takes into account the WHS presents a small enhancement.
The present work suggests a novel unit that includes thermal storage at two different temperature levels and incorporates an advanced cascade high-temperature heat pump. This heat pump includes an AHT and a vapor-compression unit, exploiting both the WHS and excess electricity. The application of two-stage systems makes it possible to increase flexibility, as the WHS and excess electricity can be exploited in cases where they have different operational profiles due to the existence of the two storage systems. The incorporation of the AHT can significantly increase the power-to-power efficiency, where in some scenarios, values over 100% are reported due to the optimal exploitation of the WHS. The present system (System-1) is compared with an alternative one with two storage levels but without the AHT. It was found that the AHT is beneficial in terms of power production, although it reduces the exergetic performance a bit.
Generally, the reported power-to-power efficiency values are greater than other reported values in the literature. The present system is efficient when there is a WHS temperature of 100 °C or more to be able to drive the AHT. A WHS temperature of less than 80 °C cannot drive the AHT, and so the configuration of System-2 has to be selected. Indicatively, it can be stated that in its optimal design, the roundtrip efficiency of System-1 is 72.86% for Twhs,in = 100 °C and 125.40% for Twhs,in = 120 °C. The typical literature values for this index are up to 60% for usual configurations; that is, 55% [16], 59% [15], 56% to 61% [17], and up to 60% [18]. Higher values have been reported for advanced systems: 64% with double-waste heat exploitation [26], 68% with a solar-driven system [22], and up to 72% with a Joule–Brayton system [19]. As such, it is obvious that the results of this analysis indicate outperformance compared to the other literature studies; thus, the present idea is a very promising one in terms of thermodynamic performance. However, it has to be highlighted that the suggested system with the AHT consumes large amounts of the WHS, and this is a critical aspect that has to be considered.
In future work, there is a need to study in detail the present configuration using dynamic analysis and further select suitable PCMs. Real input data for the profiles of the WHS and excess electricity can be used. Also, the system can be optimized by applying an economic analysis that takes into account the variable electricity cost during the day, while storage strategies can be adopted for maximizing the profit. Moreover, there is a need to design proper turbomachinery to enable operation at high temperatures and for reversible systems to operate efficiently [40]. Last but not least, a detailed exergy analysis at the component level can be performed, with the aim to determine the devices that play a significant role in the system performance and optimize them properly.

4. Conclusions

The present work has suggested a novel Carnot battery configuration with two latent storage systems that exploit a WHS. This system included an absorption heat transformer, a high-temperature heat pump, and an organic Rankine cycle. This system was compared to a similar one without the absorption heat transformer for benchmarking. The analysis was thermodynamic, and the goal was to indicate the performance of the unit in energy and exergy terms. The most valuable conclusions of this work are given below:
-
The system with the AHT (System-1) consumed higher amounts of WHS compared to the system without (System-2), because System-1 had a greater COP from its heat pump and needed higher amounts of heat input.
-
System-1 presented significantly higher roundtrip efficiency compared to System-2. For Twhs,in = 100 °C, the enhancement ranged from 92.31% for Tpcm,high = 140 °C to 26.30% for Tpcm,high = 220 °C.
-
The exergy efficiency of System-2 was a bit higher than that of System-1 due to the high amounts of the WHS that were required to properly drive System-1, which included the AHT.
-
The optimization of the AHT-HP-ORC system proved that for Twhs,in = 80 °C, the produced electricity was 503.8 kW, the roundtrip efficiency was 50.38%, and the system exergy efficiency was 34.18%; for Twhs,in = 100 °C, the produced electricity was 728.6 kW, the roundtrip efficiency was 72.86%, and the system exergy efficiency was 35.02%; and for Twhs,in = 120 °C, the produced electricity was 1254 kW, the roundtrip efficiency was 125.40%, and the system exergy efficiency was 35.36%.
-
The optimal low-stage latent storage temperature level was found to be 72.5 °C for Twhs,in = 80 °C, 110.8 °C for Twhs,in = 100 °C, and 150.0 °C for Twhs,in = 120 °C. However, the optimal high-stage latent storage temperature was 178.7 °C for Twhs,in = 80 °C, 181.5 °C for Twhs,in = 100 °C, and 187.7 °C for Twhs,in = 120 °C.
It was found that the suggested solution led to sustainable values of roundtrip efficiency, while the two-stage storage gave flexibility advantages. The challenge was the requirement for high amounts of the waste heat stream needed to drive the unit properly.

Funding

This research received no external funding.

Data Availability Statement

Data available after request.

Conflicts of Interest

The author declares no conflict of interest.

Nomenclature

cpSpecific heat capacity, kJ/kgK
ExwhsExergy rate of the WHS, kW
hSpecific enthalpy, kJ/kg
mMass flow rate, kg/s
pPressure, bar
Pel,inElectricity input into the system, kW
Pel,outElectricity output from the system, kW
TTemperature, oC
QHeat rate, kW
XLiBr concentration, %
Greek Symbols
ΔTApproach temperature, K
ηexExergetic efficiency
ηhexHeat exchanger effectiveness
ηis,CIsentropic efficiency of the compressor
ηis,PIsentropic efficiency of the pump
ηis,TIsentropic efficiency of the turbine
ηmotor,CMotor efficiency of the compressor
ηmotor,PMotor efficiency of the pump
ηmgElectromechanical efficiency
ηP2PPower-to-power efficiency
ηst,lowStorage efficiency in the low-stage
ηst,highStorage efficiency in the high-stage
ηth,orcThermodynamic efficiency of the organic Rankine cycle
Subscripts and Superscripts
aAbsorber
AHTAbsorption heat transformer
cCondenser
GElectrical generator
eEvaporator
gGenerator
HPHeat pump
hrsHeat recovery system
IHXInternal heat exchanger
isIsentropic
loss,lowThermal losses in low-stage storage
loss,highThermal losses in high-stage storage
optOptimum
orcOrganic Rankine cycle
PPump
rRefrigerant
recRecuperator
sStrong
wWeak
whsWaste heat source
whs,inWaste heat source inlet
whs,outWaste heat source outlet

Abbreviations

AHTAbsorption Heat Transformer
COPCoefficient of Performance
HPHeat Pump
HRSHeat Recovery System
IHXInternal Heat Exchanger
ORCOrganic Rankine Cycle
PCMPhase Change Material
WHSWaste Heat Source

References

  1. Sadi, M.; Arabkoohsar, A. Advanced AI technique for optimizing the operation strategy of an industrial heat pump coupled with thermal energy storage. J. Energy Storage 2026, 146, 119877. [Google Scholar] [CrossRef] [Scilit]
  2. Zafirakis, D.; Smyrnioti, I.; Papapostolou, C.; Moustris, K. From Operations to Design: Probabilistic Day-Ahead Forecasting for Risk-Aware Storage Sizing in Wind-Dominated Power Systems. Energies 2026, 19, 1972. [Google Scholar] [CrossRef] [Scilit]
  3. Quarterly Reports Confirm Continued Electricity and Gas Market Resilience. Available online: https://energy.ec.europa.eu/news/quarterly-reports-confirm-continued-electricity-and-gas-market-resilience-2025-03-31_en (accessed on 28 August 2026).
  4. Country Report—Greece—Economy and Finance—European Commission. Available online: https://economy-finance.ec.europa.eu/economic-surveillance-eu-member-states/country-pages-including-country-reports/country-report-greece_en (accessed on 28 August 2026).
  5. Lebrouhi, B.E.; Baghi, S.; Lamrani, B.; Schall, E.; Kousksou, T. Critical materials for electrical energy storage: Li-ion batteries. J. Energy Storage 2022, 55, 105471. [Google Scholar] [CrossRef] [Scilit]
  6. Qi, W.; Wang, X.; Yu, J.; Liu, Y.; Lan, P.; Cheng, Z.; Ge, S.; He, Z.; Jin, C.; Zhang, Y. Influence of radial divergent coolant flow plate channel distribution on thermal management of power batteries. Int. Commun. Heat Mass Transf. 2026, 180, 112450. [Google Scholar] [CrossRef] [Scilit]
  7. Qi, W.; Liu, Y.; Wang, X.; Ge, S.; Yu, J.; He, Z.; Tuo, J.; Wang, H.; Zhou, S.; Jin, C.; et al. Performance enhancement of battery thermal management based on liquid cooling plate channels embedded with non-uniform spiral fin structures. Appl. Therm. Eng. 2026, 300, 131501. [Google Scholar] [CrossRef] [Scilit]
  8. Paul, A.; Holy, F.; Textor, M.; Lechner, S. High temperature sensible thermal energy storage as a crucial element of Carnot Batteries: Overall classification and technical review based on parameters and key figures. J. Energy Storage 2022, 56, 106015. [Google Scholar] [CrossRef] [Scilit]
  9. Papapetrou, M.; Kosmadakis, G.; Cipollina, A.; La Commare, U.; Micale, G. Industrial waste heat: Estimation of the technically available resource in the EU per industrial sector, temperature level and country. Appl. Therm. Eng. 2018, 138, 207–216. [Google Scholar] [CrossRef] [Scilit]
  10. Dumont, O.; Frate, G.F.; Pillai, A.; Lecompte, S.; De Paepe, M.; Lemort, V. Carnot battery technology: A state-of-the-art review. J. Energy Storage 2020, 32, 101756. [Google Scholar] [CrossRef] [Scilit]
  11. Vecchi, A.; Knobloch, K.; Liang, T.; Kildahl, H.; Sciacovelli, A.; Engelbrecht, K.; Li, Y.; Ding, Y. Carnot Battery development: A review on system performance, applications and commercial state-of-the-art. J. Energy Storage 2022, 55, 105782. [Google Scholar] [CrossRef] [Scilit]
  12. Novotny, V.; Basta, V.; Smola, P.; Spale, J. Review of Carnot Battery Technology Commercial Development. Energies 2022, 15, 647. [Google Scholar] [CrossRef] [Scilit]
  13. Frate, G.F.; Ferrari, L.; Desideri, U. Rankine Carnot Batteries with the Integration of Thermal Energy Sources: A Review. Energies 2020, 13, 4766. [Google Scholar] [CrossRef] [Scilit]
  14. Fan, R.; Xi, H. Energy, exergy, economic (3E) analysis, optimization and comparison of different Carnot battery systems for energy storage. Energy Convers. Manag. 2022, 252, 115037. [Google Scholar] [CrossRef] [Scilit]
  15. Steger, D.; Regensburger, C.; Eppinger, B.; Will, S.; Karl, J.; Schlücker, E. Design aspects of a reversible heat pump—Organic rankine cycle pilot plant for energy storage. Energy 2020, 208, 118216. [Google Scholar] [CrossRef] [Scilit]
  16. Frate, G.F.; Ferrari, L.; Desideri, U. Multi-criteria investigation of a pumped thermal electricity storage (PTES) system with thermal integration and sensible heat storage. Energy Convers. Manag. 2020, 208, 112530. [Google Scholar] [CrossRef] [Scilit]
  17. Eppinger, B.; Steger, D.; Regensburger, C.; Karl, J.; Schlücker, E.; Will, S. Carnot battery: Simulation and design of a reversible heat pump-organic Rankine cycle pilot plant. Appl. Energy 2021, 288, 116650. [Google Scholar] [CrossRef] [Scilit]
  18. Dumont, O.; Lemort, V. Mapping of performance of pumped thermal energy storage (Carnot battery) using waste heat recovery. Energy 2020, 211, 118963. [Google Scholar] [CrossRef] [Scilit]
  19. McTigue, J.D.; Farres-Antunez, P.; Sundarnath J, K.; Markides, C.N.; White, A.J. Techno-economic analysis of recuperated Joule-Brayton pumped thermal energy storage. Energy Convers. Manag. 2022, 252, 115016. [Google Scholar] [CrossRef] [Scilit]
  20. Weitzer, M.; Müller, D.; Steger, D.; Charalampidis, A.; Karellas, S.; Karl, J. Organic flash cycles in Rankine-based Carnot batteries with large storage temperature spreads. Energy Convers. Manag. 2022, 255, 115323. [Google Scholar] [CrossRef] [Scilit]
  21. Henchoz, S.; Buchter, F.; Favrat, D.; Morandin, M.; Mercangöz, M. Thermoeconomic analysis of a solar enhanced energy storage concept based on thermodynamic cycles. Energy 2012, 45, 358–365. [Google Scholar] [CrossRef] [Scilit]
  22. Bellos, E.; Tzivanidis, C.; Said, Z. Investigation and optimization of a solar-assisted pumped thermal energy storage system with flat plate collectors. Energy Convers. Manag. 2021, 237, 114137. [Google Scholar] [CrossRef] [Scilit]
  23. Yu, J.; Jia, T.; Tan, C.; Gao, Z.; Gu, X.; Zhou, D.; Zhao, Y.; Dai, Y. Carnot battery integrated with ultra-high-temperature heat pump and parabolic trough collector for hybrid PV-concentrating solar power plants. Renew. Energy 2026, 275, 126271. [Google Scholar] [CrossRef] [Scilit]
  24. Yang, Z.; Zhao, X.; Liu, R.; Xu, W.; Chen, R.; Ma, J.; Zhao, L.; Gao, R. Optimization of waste heat allocation and temperature matching for Carnot battery. Energy Convers. Manag. 2026, 367, 121930. [Google Scholar] [CrossRef] [Scilit]
  25. Lykas, P.; Bellos, E.; Tzivanidis, C. Dynamic investigation of a multiple energy production and storage system for a residential building. Renew. Energy 2026, 256, 123938. [Google Scholar] [CrossRef] [Scilit]
  26. Bellos, E. Thermodynamic analysis of a Carnot battery unit with double exploitation of a waste heat source. Energy Convers. Manag. 2024, 299, 117844. [Google Scholar] [CrossRef] [Scilit]
  27. EES: Engineering Equation Solver | F-Chart Software: Engineering Software. Available online: https://fchartsoftware.com/ees/ (accessed on 31 March 2023).
  28. Bellos, E. An efficient cascade high temperature heat pump for heat production in the range of 200 °C to 300 °C. Appl. Therm. Eng. 2026, 300, 131343. [Google Scholar] [CrossRef] [Scilit]
  29. Eppinger, B.; Zigan, L.; Karl, J.; Will, S. Pumped thermal energy storage with heat pump-ORC-systems: Comparison of latent and sensible thermal storages for various fluids. Appl. Energy 2020, 280, 115940. [Google Scholar] [CrossRef] [Scilit]
  30. Bellos, E.; Arabkoohsar, A.; Lykas, P.; Sammoutos, C.; Kitsopoulou, A.; Tzivanidis, C. Investigation of a solar-driven absorption heat transformer with various collector types for industrial process heating. Appl. Therm. Eng. 2024, 244, 122665. [Google Scholar] [CrossRef] [Scilit]
  31. Rivera, W.; Cerezo, J.; Rivero, R.; Cervantes, J.; Best, R. Single stage and double absorption heat transformers used to recover energy in a distillation column of butane and pentane. Int. J. Energy Res. 2003, 27, 1279–1292. [Google Scholar] [CrossRef] [Scilit]
  32. Pátek, J.; Klomfar, J. A computationally effective formulation of the thermodynamic properties of LiBr–H2O solutions from 273 to 500 K over full composition range. Int. J. Refrig. 2006, 29, 566–578. [Google Scholar] [CrossRef] [Scilit]
  33. Wang, L.; Li, H.; Bu, X.; Wang, H.; Ma, W. Performance Study of a Double Absorption Heat Transformer. Energy Procedia 2017, 105, 1473–1482. [Google Scholar] [CrossRef] [Scilit]
  34. Wang, H.; Li, H.; Bu, X.; Wang, L. Effects of the generator and evaporator temperature differences on a double absorption heat transformer—Different control strategies on utilizing heat sources. Energy Convers. Manag. 2017, 138, 12–21. [Google Scholar] [CrossRef] [Scilit]
  35. Zühlsdorf, B.; Bühler, F.; Bantle, M.; Elmegaard, B. Analysis of technologies and potentials for heat pump-based process heat supply above 150 °C. Energy Convers. Manag. X 2019, 2, 100011. [Google Scholar] [CrossRef] [Scilit]
  36. Pantaleo, A.M.; Camporeale, S.M.; Sorrentino, A.; Miliozzi, A.; Shah, N.; Markides, C.N. Hybrid solar-biomass combined Brayton/organic Rankine-cycle plants integrated with thermal storage: Techno-economic feasibility in selected Mediterranean areas. Renew. Energy 2020, 147, 2913–2931. [Google Scholar] [CrossRef] [Scilit]
  37. Gonidaki, D.; Lykas, P.; Sammoutos, C.; Kitsopoulou, A.; Polychronakis, K.; Mitsopoulos, G.; Tzivanidis, C.; Bellos, E. Multi-Criteria Design of Industrial Process Heat Solutions, Including Concentrating Solar Thermal Collectors, High Temperature Heat Pumps, and Boilers. Designs 2026, 10, 62. [Google Scholar] [CrossRef] [Scilit]
  38. Zühlsdorf, B.; Jensen, J.K.; Cignitti, S.; Madsen, C.; Elmegaard, B. Analysis of temperature glide matching of heat pumps with zeotropic working fluid mixtures for different temperature glides. Energy 2018, 153, 650–660. [Google Scholar] [CrossRef] [Scilit]
  39. Song, J.; Gu, C. Parametric analysis of a dual loop Organic Rankine Cycle (ORC) system for engine waste heat recovery. Energy Convers. Manag. 2015, 105, 995–1005. [Google Scholar] [CrossRef] [Scilit]
  40. Liang, T.; Vecchi, A.; Knobloch, K.; Sciacovelli, A.; Engelbrecht, K.; Li, Y.; Ding, Y. Key components for Carnot Battery: Technology review, technical barriers and selection criteria. Renew. Sustain. Energy Rev. 2022, 163, 112478. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.