Abstract
A measurement setup was developed for leakage determination in flanged joints with diameters up to 654 mm at temperatures ranging from −196 °C to +500 °C and pressures up to 200 bar. The operating principle is based on the differential pressure method, enabling the utilization of both helium and gaseous hydrocarbons as working media. The setup was validated through specific leak rate measurements on standard DN40/PN40 multigraphene gaskets in accordance with EN 13555, showing close agreement with data obtained from the reference Amtec TEMES fl.ai1 test rig. An intrinsically safe architecture combined with strain-gauge monitoring of tightening loads enabled the transition from bench-scale characterization to in situ testing of large-scale gaskets.
1. Introduction
Ensuring the tightness of flanged joints is a critical factor for the operational and environmental safety of gas transmission pipelines and petrochemical facilities [1,2,3]. Leakages of volatile organic compounds and flammable gases not only lead to substantial economic losses but also pose severe industrial hazards [4,5]. The modern oil and gas sector operates under extreme conditions, ranging from cryogenic natural gas liquefaction to high-temperature petrochemical synthesis [6,7,8].
Historically, asbestos-based gaskets dominated sealing applications [9,10]. Environmental and health regulations, however, have led to their global prohibition [11]. Although the subsequent adoption of polymer composites and polytetrafluoroethylene enhanced joint integrity and reduced environmental impact, economic considerations currently limit their broader commercial use [12,13,14]. Conventional soft materials, such as elastomers and aramids, often fail to withstand extreme temperature fluctuations [15,16], while rigid metallic gaskets necessitate high-precision flange face finishing [17,18]. Consequently, multigraphene structures have found widespread deployment owing to their exceptional chemical resistance and thermal stability [19,20,21].
Operational reliability of flanged joints is significantly governed by the capacity of the sealing material to adapt to transient pressure and temperature conditions [22,23]. These structures demonstrate enhanced sealing efficiency by virtue of their layered morphology [24,25,26]. Their characteristics, nevertheless, are closely linked to both the quality of graphite particle preparation [27,28] and the specific features of the manufacturing process [29,30]. The high thermal conductivity of these structures, governed by their synthesis conditions [31], minimizes thermal stresses within the flange assembly but concurrently necessitates highly sensitive instrumentation for leak verification.
Conventional measurement instrumentation, including the industry-benchmark Amtec TEMES fl.ai1 system (Amtec, Lauffen, Germany), is typically restricted to a maximum gasket outer diameter of 160 mm and operating pressures up to 200 bar [32,33,34]. These constraints preclude testing on large-diameter flanges under simulated field conditions utilizing gaseous hydrocarbons as the working medium, as opposed to helium.
Leveraging previous expertise in highly thermally conductive multigraphene materials [35] and thermal conductivity characterization rigs [36], an experimental setup has been developed for leak verification of large-diameter flanged joints. The apparatus enables testing of gaskets with outer diameters up to 654 mm within a temperature range of −196 to +500 °C and pressures up to 200 bar, utilizing the differential pressure method with actual process media, such as methane.
The integration of a strain-gauge system for monitoring axial loads, combined with an intrinsically safe design, facilitates a shift from bench-scale studies to evaluating the leak-tightness and operational reliability of full-scale flange assemblies.
2. Materials and Methods
2.1. Sample Preparation
Multigraphene gaskets of various diameters serve as reference specimens because of their reliable sealing capability and consistent reproducibility. The visual appearance of such gaskets is presented in Figure 1a. The gaskets consist of a compacted multigraphene material possessing a density of 1.0 g·cm−3. To ensure high edge quality, the specimens were blanked from sheets utilizing customized cutting dies.
Figure 1.
(a) Macroscopic appearance of the gaskets; (b) morphology of the starting flake graphite; (c) morphology of the expanded graphite; (d) surface morphology of the compacted multigraphene material; and (e) compressibility, recovery, and resiliency of multigraphene gaskets.
Two sizes of flange gaskets were employed in this study. The smaller specimen, designated as D1, has outer and inner diameters of 92 and 49 mm, respectively. The dimensions of the D1 gasket comply with the EN 13555 standard (DN40/PN40). The large-scale D2 specimen features an outer diameter of 308 mm and an inner diameter of 219 mm. This specific gasket nomenclature facilitated the size effect assessment in leakage tests.
Natural flake graphite with a particle size of 200–300 μm served as the raw material, with its morphology illustrated in Figure 1b. This precursor was then converted into a graphite intercalation compound via treatment with concentrated nitric acid [37].
The stage number of the resulting compound was confirmed by X-ray diffraction. To obtain oxidized graphite, the product was separated from the excess acid. Distilled water at room temperature was added to the oxidized graphite, and the mixture was stirred for several minutes and then filtered using filter paper. The collected material was dried at 50 °C for about 4 h until a constant weight was achieved. Therefore, chemical intercalation and subsequent thermal shock at 900 °C yielded the multigraphene structure illustrated in Figure 1c, a process accompanied by a 150- to 200-fold increase in the linear particle dimensions. The prepared thermally expanded graphite was then compacted to a density of 1.0 g·cm−3. Figure 1d indicates that the final material features high uniformity and low porosity.
Evaluation of the mechanical properties of the sealing material was performed using an Instron 5965 (Instron, Norwood, MA, USA) universal testing machine. The testing procedure involved uniaxial compression carried out according to the EN 13555 standard. The average values of compressibility and recovery were 49% and 9%, respectively, as shown in Figure 1e. Notably, the material compressibility directly determines its capability to conform to flange surface irregularities. Conversely, high recovery is vital to compensate for the thermal expansion of the flanges, ensuring contact stability during the dynamic temperature variations investigated later in this work.
Ultimate tensile strength measurements for the multigraphene material yielded values above 3 MPa. This parameter demonstrates the robust structural integrity of the gasket during installation loads. The fracture behavior indicates a high cohesive strength between the multigraphene layers.
Further mechanical characterization involved acquiring the specimen’s experimental deformation curves via an AMTEC TEMES fl.ai1 test rig. The relationship between the axial pressure and the material thickness variation was utilized to evaluate the elastic modulus. Specifically, the modulus of elasticity at a defined clamping pressure of 40 MPa was evaluated based on the slope of the unloading curve. For the studied multigraphene structure, this value was found to be above 1.1 GPa. Selecting these specific gasket stresses facilitated the assessment of the material’s elastic response under standard operating conditions. Importantly, the parameters are essential for ensuring joint tightness under cyclic loading conditions.
2.2. Pneumatic Circuit
Designed for the tightness evaluation of flanged joints featuring diameters up to 654 mm, the developed setup allows for the use of both helium and methane as the working medium, contrasting with most conventional testing systems. Measurements are carried out over a temperature range spanning from −196 °C to +500 °C. The testing apparatus operates by implementing the differential pressure method. Specifically, the pneumatic circuit of the experimental setup is presented in Figure 2.
Figure 2.
Pneumatic circuit diagram of the setup.
Gas feeding is carried out via the inlet ports S1 and S2. Line S1 is intended for the delivery of working gases, specifically helium or methane, while line S2 serves to supply nitrogen to the circuit purging system under pressure. To purify the incoming gases, filter elements F1 and F2 are installed directly upstream of the control valves. Adjustment of the inlet flow is performed by needle valves V1 and V3. Specifically, valve V1 ensures precise metering of the working gas from the main supply line, whereas valve V3 is responsible for delivering the purified nitrogen.
These feed lines join before the isolation valve V2, which separates the gas preparation stage from the rest of the circuit. Then, the gas flow is distributed to the functional components through a common manifold system, where pressure monitoring is provided by the PT/PS1 electronic transmitter and the PG1 dial pressure gauge, the latter enabling visual control. Connection of the tested flanged joint is established through valve V4. Downstream of this valve, the gas passes through filter F3, with the connection to the flange assembly implemented via an S3-type quick coupling. The test specimen is placed between two steel flanges to ensure tightness. Valve V5 serves for the rapid venting of pressure from the sample working line. Meanwhile, valve V6 connects the distribution manifold to the precision pressure control line, where the PS3 sensor serves to monitor and log static parameters.
A reference capacity vessel with a volume of 50 cm3 serves as a calibrated measurement standard. Meanwhile, the DPT/PS2 differential pressure transmitter is piped in parallel with the V8 shut-off valve to measure the pressure difference between the reference volume and the flange assembly line. The employed sensors feature an accuracy of 0.1% of full scale, which enables the detection and recording of minor gas leaks.
Discharge and evacuation lines are provided to prepare the setup for operation, with exhaust gas being removed through the EV1 discharge valve. To handle emergency pressure relief upon exceeding preset thresholds, the EV2 valve is utilized alongside a mechanical safety valve set to open at 200 bar. All these discharge lines vent to the atmosphere via outlet S4. Furthermore, complete removal of system impurities is carried out via the S5 vacuum port, thereby eliminating any impact of residual air on the experimental medium purity.
The measurement procedure begins by mounting the multigraphene gasket into the flange assembly, followed by applying a design axial load to the flanges for initial material compression. Once the system is sealed, air evacuation from the internal lines is performed. A vacuum transducer is employed to monitor the vacuum depth. Then, the working gas is fed into the system via valve V1, and the test chamber pressure is gradually raised to a predetermined operating level. After pressure stabilization, valve V8 is closed to isolate the measurement volumes, allowing the DPT/PS2 sensor to capture the pressure change rate dP/dt.
The differential pressure method is based on recording the pressure decay in a closed volume. This approach ensures high system sensitivity to minor working gas flows. The measurement process begins with the simultaneous filling of the test chamber and the reference capacity. After the thermodynamic parameters stabilize, shut-off valve V8 is closed, separating the system into two isolated circuits with identical initial pressure. Any leakage of the test specimen leads to a pressure drop in the working circuit.
The resulting pressure difference between the reference capacity and the test chamber is captured by the DPT/PS2 differential pressure transducer.
Based on the ideal gas law, the specific mass leak rate is determined via the following equation:
where denotes the combined volume of the test loop and connecting lines; is the universal gas constant; is the molar mass of the gas; is the absolute temperature of the medium monitored by thermocouples in real time; is the mean diameter of the gasket, and dP/dt is the pressure change rate recorded by the DPT/PS2 transducer.
The mean diameter of the gasket is calculated as the arithmetic average of its outer and inner contact diameters:
where and are the outer and inner diameters of the gasket sealing zone, respectively. For standard DN40/PN40 testing configurations per EN 13555, these dimensions correspond to the actual contact area under compression.
For practical calculations, the specific volumetric leak rate λ, normalized to standard atmospheric conditions, is frequently used:
where V is the effective volume of the test circuit, l; ΔP is the measured change in differential pressure, mbar; Δt is the corresponding measurement time, s; is the mean diameter of the gasket sealing zone, m; Pstd = 1013.25 mbar is the standard absolute pressure; Tstd = 293.15 K is the standard temperature; and Ttest is the measured absolute gas temperature during the test, K.
The effective volume, pressure change, gas temperature, and gasket diameter used in Equations (1)–(3) were determined separately for each test configuration. Before each test, the total system volume was determined by gas expansion using a calibrated volume Vcal = 96.61 cm3. After pressurization to approximately 40 bar and 30 s stabilization, P1 was recorded. The valve was then opened to connect the calibrated volume to the test section, and P2 was recorded after a further 30 s stabilization. Assuming constant temperature, we have:
where Vsys is the total internal volume of the system after connection of the flange assembly; P1,g and P2,g are the gauge pressures measured before and after gas expansion, respectively.
The effective volume was calculated as:
where VDPT is the 50 cm3 internal volume of the differential pressure transducer chamber. The relative uncertainty of V was estimated as 1.5%.
V = Vsys − VDPT
During leakage measurements, ΔP was recorded continuously by the DPT/PS2 transducer (accuracy ±0.1% FS). The gas temperature was measured using thermocouples. The inner and outer gasket diameters were measured using a digital caliper, with a maximum relative contribution of about 0.02%. The combined relative uncertainty of λ was calculated by the root-sum-of-squares method:
where PFS is the full-scale range of the differential pressure transducer; ΔTlim is the permissible absolute error of the thermocouple according to its calibration documentation, and Ttest is the measured temperature.
The dominant contributions were those of the effective volume and pressure change rate. The temperature contribution was smaller, while that of the gasket diameter was negligible. The combined uncertainty was evaluated separately for each experimental point.
The application of the reference capacity allows minimizing the influence of ambient temperature fluctuations. Thermal drift affects both arms of the differential measurement circuit equally. This eliminates the appearance of false leak signals during changes in climatic conditions.
2.3. Device Control System
The diagram of the control system is shown in Figure 3. The system is built on a modular industrial architecture. The central element of the structure is a communication line for digital signal transmission. Peripheral measurement units are integrated via this common bus. This topology ensures a high polling rate for the primary transducers. The architecture of the system enables real-time synchronization of data from various sensors.
Figure 3.
Block diagram of the control system.
Testing process monitoring is performed using a local operator panel. The panel visualizes current parameters and allows modifying the operating modes of the actuators. The software interface of the panel ensures the interaction between the researcher and the software complex of the test rig.
To measure temperature fields, a dedicated measurement segment is integrated into the system. Thermocouples record the thermal state of key zones within the test chamber. The connection of these primary transducers is implemented via a dedicated thermo-analog interface of Analog module 1. This module performs cold junction compensation and digitization of low-voltage signals. Temperature data are required for introducing corrections into the leak calculation algorithms. The monitoring system maintains control over thermal conditions during the experiments. The modular structure allows changing the number of monitoring points if necessary.
The pressure of the experimental medium is monitored by Analog module 2. A gauge pressure sensor and a differential pressure transducer are integrated into this unit.
An intrinsically safe barrier eliminates the possibility of electrical discharge. The pressure sensor records the pressure inside the working chamber of the setup. The differential sensor determines the pressure difference between the chambers of the measurement system. These data are used to calculate the standard characteristics of the gas flow through the specimen.
Monitoring of the evacuation parameters is assigned to Analog module 3. The vacuum pressure interface ensures coupling with a vacuum pressure sensor. This sensor monitors the system preparation before the test starts. Preliminary evacuation of atmospheric air is an obligatory step to ensure the purity of the experiment. The module transfers data on the achieved vacuum level directly to the central controller. Stable readings from the vacuum gauge confirm the absence of obvious defects in the assembly of the test tooling. The software complex blocks gas supply if the preliminary vacuum level in the loop is insufficient.
Axial compression loads on the multigraphene gaskets are measured by a load cell subsystem. This subsystem includes two load cell analog modules. These units provide power and polling for the installed load cells. The load cells are arranged along the flange perimeter to monitor load uniformity. This distributed measurement layout allows detecting misalignments during the mounting of large-scale gasket specimens. The current values of mechanical stresses are transmitted via the digital bus to the data logging unit. The correlation of leakage and the tightening load allows analyzing the characteristics of flanged joints.
An external leak detector serves as an auxiliary device for conducting the tests. Its application allows verifying the results obtained by the pressure decay leak measurement method. When connected, the device transmits data to the common network via a standard protocol. The integration of this instrument expands the capabilities of the setup when searching for local gas leaks. Its operation is synchronized with the measurement cycle via the communication line. If direct flow registration is not required, the leak detector is excluded from the circuit.
Test results are compiled into structured data files and plots. The system ensures data storage in a local database and on external media. The software enables statistical analysis and generates comprehensive reports. These documents include the main monitored parameters, such as temperature, pressure, and mechanical loads.
2.4. Design and Components of the Test Rig
The developed experimental setup for large-diameter flange leakage measurements is illustrated in Figure 4. A general view of the system configuration is shown in Figure 4a,b for small and large flanges, respectively, with the process gas manifold and its dual-stage pressure regulators highlighted in Figure 4c. The internal configuration of the pneumatic system, designed for gas supply and monitoring, is further detailed in Figure 4d. The setup enables automated measurements across a range of pressures and temperatures.
Figure 4.
Experimental setup with (a) small and (b) large flanges, (c) the process gas manifold, and (d) the pneumatic system.
The cryogenic testing methodology involves integrating a liquid nitrogen supply system and a specialized thermal insulation jacket into the measurement loop. The thermal insulation setup is integrated during the test section preparation. Specifically, a metal distribution disk is positioned on a dielectric substrate, and the primary insulation shell is subsequently fixed over it. The flange joint configuration subjected to testing is displayed in Figure 5.
Figure 5.
Components of the setup: (a) small flange for high-temperature and cryogenic testing; (b) custom muffle furnace; (c) cryogenic components; and (d) control system.
Prior to the primary measurements, the system’s measuring volume is calibrated. The calibration procedure is executed by introducing a predefined volume of the test gas into the loop. For the identification of technologically significant leakages, testing is carried out for 3–4 h, whereas in cases of high gasket tightness, the measurement period may extend beyond 20 h. Following the test duration, the digital monitoring system automatically computes the permeability of the multigraphene gasket. Finally, the software suite processes the acquired data and logs them into the final test report.
2.5. Comparative Analysis and Novelty of the Test Setup
To demonstrate the metrological and structural novelty of the developed measurement setup, its core parameters are quantified and directly benchmarked against the commercial system Amtec TEMES fl.ai1. While commercial equipment is highly effective for material-level investigation using small-diameter gaskets, there are some limitations when evaluating full-scale industrial joints under multi-factor extreme exposures. A technical comparison of the proposed architecture is presented in Table 1.
Table 1.
Comparison between the commercial system and the developed experimental setup.
As demonstrated by the quantitative indicators, the developed setup overcomes critical scale and media constraints by enabling the evaluation of large-diameter multigraphene gaskets (up to 654 mm) under significantly higher fluid pressures (up to 200 bar) and broader temperature margins (from −196 °C to +500 °C). The engineering novelty lies in the integration of the differential pressure measurement circuit with automated safety systems and precise multi-channel structural monitoring. Specifically, the reference-volume differential configuration inherently isolates the pressure changes from ambient thermal fluctuations during prolonged testing cycles. The three-module automated control system provides safe handling of the methane via vacuum-interlocked pneumatic sequencing. This comprehensive hardware-software architecture bridges the gap between material measurements and full-scale operational reliability analysis.
The temperature and pressure limits stated above define the design envelope of the apparatus rather than the range experimentally demonstrated in this study. The reported tests were performed at −70, 20, and 300 °C and at gas pressures up to 40 bar, covering low-temperature gas processing, ambient operation, and elevated-temperature refinery and gas-processing conditions.
High-temperature operation is achieved using split-type flexible ceramic band heaters with closed-loop thermocouple control, whereas the lower temperature limit is provided by the liquid-nitrogen cooling system and thermal insulation described above. The stainless-steel flanges are selected in accordance with the pressure–temperature (P–T) ratings specified in EN 1092-1. The pneumatic circuit includes stainless-steel double-ferrule compression fittings rated for pressures up to 700 bar. For each test condition, the allowable pressure is limited by the lowest-rated component in the assembled circuit, including the flanges, tubing, fittings, valves, and pressure transducers.
In summary, the comparison shows that the developed setup expands the limits of standard laboratory testing. It allows for realistic evaluation of full-scale gaskets under actual industrial conditions.
3. Results and Discussion
3.1. Validation of the Experimental Setup
Validation outcomes for the designed experimental apparatus were compared against the reference Amtec TEMES fl.ai system, as illustrated in Figure 6. The investigation focused on DN40/PN40 multigraphene gaskets with inner and outer diameters of 49 and 92 mm, respectively, with the sample geometry and testing methodology selected in compliance with EN 13555. Gasket tightness was evaluated across a pressure range of 10 to 40 bar, employing helium as the working medium to ensure high sensitivity for micro-leakage detection.
Figure 6.
Measurement verification of the designed experimental apparatus. The solid green line represents the trend, while blue and red markers show the experimental data. Error bars are omitted for clarity.
The data presented in Figure 6 represent the directly measured pV leak rate, here defined as the specific leakage rate. It was calculated from the measured pressure change and the effective volume of the test system as:
where is expressed in mbar·L/s, V is the effective test volume, and is the measured rate of pressure change.
This quantity was used for the validation shown in Figure 6 because the same gasket size and test conditions were used for both the developed setup and the reference AMTEC system. Therefore, the use of the same definition of specific leakage rate allows a direct comparison of the two datasets. When normalization to standard conditions and gasket circumference is required, the specific leakage rate can be further converted using Equation (3). Similarly, Equation (1) can be used to convert the measured value into the corresponding circumference-normalized mass leak rate.
Throughout the testing procedure, a constant gasket compressive stress of 40 MPa was sustained. This was achieved using a system of strain-gauge studs for precise load control, which successfully provided uniform axial pressure distribution while maintaining stable test conditions.
Specific helium leak rates on the Amtec system were measured at discrete pressure levels of 10, 20, and 40 bar. Testing on the developed setup encompassed five leak rate measurements, three of which replicated these Amtec reference pressures, while the remaining two served as additional intermediate data points at 15 and 30 bar. To ensure statistical validity, the final specific leak rates were calculated as the arithmetic mean of three independent measurements.
To ensure reliability, all validation tests were performed in triplicate to calculate standard deviations. The maximum relative deviation from the reference Amtec system does not exceed 5% across the entire pressure range. Based on the error propagation law, the instrumental uncertainty budget includes the differential pressure sensor (±0.1%), reference volume (±1.5%), and thermocouples (±0.5 °C). The resulting combined expanded uncertainty (U, k = 2) for the specific leakage rate is within ±4.0%.
The non-linear relationship observed between the specific leakage rate and gas pressure is likely governed by the predominant role of Knudsen diffusion through the microporous network of the material [38,39,40]. At a density of 1.0 g·cm−3, the characteristic channel dimensions become comparable to the mean free path of the working gas molecules.
Under these conditions, molecule–wall collisions within the nanopores dominate over intermolecular interactions, shifting the transport mechanism from a viscous flow to a selective diffusion regime [41]. Crucially, a steady increase in the leak rate indicates that the pores remain partially open under a 40 MPa compressive stress, sustaining a continuous helium diffusion path that accelerates with rising fluid pressure. This behavior is supported by the high material compressibility (49%), which ensures efficient conformability to the steel flange microrelief at 40 MPa and consequently reduces Greenwood–Williamson interfacial leakage to negligible values [42].
The resulting experimental curves exhibit a characteristic non-linear growth in the specific leak rate; notably, the data points obtained using the developed setup show excellent agreement with the reference Amtec measurements. At the maximum pressure of 40 bar, the leak rate values for both systems asymptotically approach a common value of 1.0 × 10−2 mbar·L·s−1, which verifies that the sealing performance of the multigraphene material remains consistent across distinct flange configurations.
Consistent alignment between the experimental data from the developed setup and the Amtec system over a broad pressure range confirms the validity of the pneumatic system architecture, as well as the metrological robustness of the deployed automation and control instrumentation. Successful validation of the setup on reference specimens paves the way for leak characterization of large-diameter gaskets up to 654 mm across a diverse range of process gases and thermal regimes. Incorporating intrinsically safe barriers along with an automated monitoring system ensures safe experimental operations when utilizing hazardous gases like methane across a wide range of ambient pressures.
3.2. Scale Factor and Improper Assembly on Leakage
Scaling the gasket outer diameter from D1 = 92 mm to D2 = 308 mm extends the sealing perimeter, thereby increasing the overall potential gas leakage rate. Field operations on large-diameter flange assemblies typically complicate achieving proper component alignment and uniform bolt preloads. Consequently, this study evaluates the combined influence of the scale effect and tightening asymmetry on the sealing performance of multigraphene gaskets. Non-uniform loading was simulated via an asymmetric bolt load distribution around the perimeter to assess the conformability of multigraphene in maintaining a reliable seal under localized gasket stress gradients.
A general view of the large-scale flange assembly with an installed 308 mm diameter multigraphene gasket and a system of strain-gauge studs is shown in Figure 7a. To evaluate the stress–strain state of the assembly, a three-dimensional finite element model was developed, as presented in Figure 7b,c. Specifically, on the geometric CAD model shown in Figure 7b, diametrically opposed pairs of mounting studs utilized for bolt load monitoring are highlighted in blue and red.
Figure 7.
Experimental and numerical analysis of non-uniform flange assembly configurations: (a) visual appearance of the large-diameter flange; (b) geometric CAD model with highlighted reference studs; (c) finite element mesh of the assembly; simulated stress–strain states of the fasteners under (d) nominal tightening, (e) assembly misalignment, and (f) utilization of studs with contrasting mechanical properties.
The FEM assembly was discretized using a hex-dominant mesh with a fixed boundary condition at the pipe base and friction contact at the flange–gasket interfaces. This numerical simulation serves as a qualitative tool to visualize the stress–strain states and joint deformation, supporting the experimental results.
Three distinct flange assembly configurations were evaluated to simulate the stress–strain states of the fasteners, as depicted in Figure 7d–f. In particular, Figure 7d illustrates a symmetric stress distribution corresponding to the nominal uniform tightening, whereas Figure 7e demonstrates a pronounced asymmetry induced by a prescribed flange misalignment. Additionally, Figure 7f displays the stress profile for a scenario employing fasteners with highly contrasting mechanical properties. In this layout, one stud is intentionally fabricated from a ductile steel featuring a low yield strength, leading to severe plastic deformation before reaching the nominal clamping force. The other stud, made of high-strength steel, remains in the elastic state and successfully sustains the target bolt load.
Aimed at evaluating the measurement capabilities of the developed test setup and analyzing the scale effect, this study investigates the influence of geometric parameters on the sealing performance of flanged joints. Experimental data for three control groups of gaskets are presented in Figure 8. Small-diameter reference samples D1 served as the baseline for comparison, whereas the large-scale gaskets were evaluated under two distinct configurations: a nominal, uniform bolt preload D2-G and a prescribed tightening asymmetry designed to simulate flange misalignment D2-B.
Figure 8.
Specific leak rates under various thermal conditions demonstrating scale and assembly effects at −70 °C (a), 20 °C (b), and 300 °C (c) for the D1, D2-G, and D2-B configurations. The relative uncertainty is 5%.
It should be noted that the leak rates presented in Figure 8 represent the integral helium flow through the entire circumference and porous structure of the gasket and should not be interpreted as leakage through a single geometrical opening. Approximate correlations between leak rate and the size of a local defect, such as a hair trapped on a sealing surface, are generally derived for air flowing through an isolated gap under specified air-to-vacuum conditions and are therefore not directly applicable to the present tests with helium under positive pressure. The reliability of the measured leakage rates was confirmed by the validation presented in Figure 6, where the results obtained for the D1 gasket using the developed setup showed close agreement with those measured using the reference AMTEC TEMES fl.ai1 system. The validated measurement method was subsequently applied to the large-diameter D2-G configuration presented in Figure 8.
At an ambient temperature of 20 °C, the specific leak rate for the D1 reference sample was found to be 1.0 × 10−2 mbar·L·s−1. For the large-scale gasket in the D2-G configuration, this value increases by more than threefold to 3.6 × 10−2 mbar·L·s−1.
Thus, accordingly, increasing the seal diameter expands the integral flow cross-section of the microchannels. Coupled with the heightened non-uniformity of contact stresses inherent to large-diameter flanges, this mechanism is suggested to non-linearly degrade the sealing performance of the flange joint [43,44]. This effect can be interpreted as the primary cause for the abrupt drop in sealing performance observed under asymmetric bolt loading D2-B, where the specific leakage rate reaches 18 × 10−2 mbar·L·s−1, which underscores the critical importance of uniform bolt preload.
At 300 °C, the observed dependence of gas permeability on the gasket diameter persists. The specific leakage rate for sample D1 is 1.8 × 10−2 mbar·L·s−1, whereas for the D2-G configuration, this parameter increases more than threefold, reaching 6.3 × 10−2 mbar·L·s−1.
This increase can be primarily attributed to the thermal expansion of structural microchannels within the multigraphene matrix. According to [45,46], the main factor in seal degradation is the non-linear deformation of the material, which worsens upon heating. This behavior is suggested to induce the opening of micro-gaps within zones of reduced contact pressure, thereby promoting higher leakage rates. Under asymmetric bolt loading D2-B, the specific leakage rate reaches a peak value of 32 × 10−2 mbar·L·s−1.
Cooling to −70 °C induces the most severe reduction in the leak-tightness of the flange joints. The specific leak rate for sample D1 increases to 16 × 10−2 mbar·L·s−1, and for the D2-G configuration reaches 59 × 10−2 mbar·L·s−1.
At cryogenic temperatures, the primary driver of seal degradation is the differential thermal contraction of the assembly components, which induces bolt load relaxation and compromises the conformability of the gasket. This effect is maximized under asymmetric bolt loading D2-B, where the specific leak rate reaches a peak value of 293 × 10−2 mbar·L·s−1. These findings confirm that under low-temperature conditions, assembly precision and bolt preload control are critical to preventing depressurization in large-diameter flange joints.
The obtained results show that the scale effect leads to a stable increase in the specific leak rate during the transition from small-diameter samples to large-scale gaskets across the entire temperature range. Nevertheless, the quality of assembly remains the governing factor dictating sealing reliability. The prescribed load asymmetry increases the gas permeability of the flange joint more than fivefold both at room temperature and under thermal extremes of −70 and +300 °C. Consequently, extreme thermal exposure severely degrades the sealing performance, rendering localized stress asymmetry the dominant driver of joint depressurization.
3.3. Methane Leakage Tests
In order to demonstrate the measurement capabilities of the developed test setup, large-diameter multigraphene gaskets were evaluated under conditions designed to simulate the operating regimes of industrial gas transmission systems.
This phase enabled the evaluation of the flange assembly sealing performance when substituting the surrogate helium medium with the target hydrocarbon gas, methane. Figure 9 presents the specific leak rates as a function of operating pressure for the D2 = 308 mm diameter gaskets. The observed behavior stems from discrepancies in both the molecular kinetic diameters and the dynamic viscosities of the evaluated gases. In contrast to thermal effects, increasing pressure does not alter the activation energy barrier for permeation; instead, it elevates the pressure gradient, thereby accentuating the differences in their transport mechanisms. Consequently, methane permeation through the structural microchannels of the multigraphene gasket proceeds at a significantly lower rate than helium transport.
Figure 9.
Specific leakage rate of helium for D2-B (blue line) and methane for D2-B (red line) and D2-G (green line). The relative uncertainty is 5% for helium and 4% for methane (error bars are omitted for clarity).
As established in [47], this selectivity exhibits an exponential dependence on the process activation energy and is described by the temperature-activated gas flux J equation:
where the activation energy Eact is governed by the ratio between the gas molecular diameter dg and the effective pore size a, as well as a scaling exponent n dictating the sensitivity to molecular size:
Since the kinetic diameter of methane (~0.380 nm) exceeds the kinetic diameter of helium (~0.260 nm), the energy barrier for permeation in the narrow channels of multigraphene increases significantly. Consequently, the layered structure of the material functions as a molecular sieve, effectively suppressing the permeability of the heavier hydrocarbon molecules.
Experiments under an artificially induced tightening load asymmetry (methane D2-B) were conducted to evaluate the stability of the multigraphene sealing performance. Despite the intentional flange misalignment, the methane leakage rate exhibits only a minor increase. At the peak operating pressure of 40 bar, the specific methane leak rate for the D2-B assembly is 2.1 × 10−2 mbar·L·s−1, which remains below the baseline helium permeability measured under a nominal, uniform bolt preload of 2.5 × 10−2 mbar·L·s−1. Thus, the low permeability of multigraphene to methane compensates for the tightening asymmetry, maintaining high joint leak-tightness even under assembly defect conditions.
4. Conclusions
A custom leakage measurement setup and a methodology for specific leak rate determination were developed, enabling the investigation of hydrocarbon gas permeability in large-diameter multigraphene flanged joints. The developed test setup accommodates the evaluation of flange joints with diameters up to 654 mm, substantially outperforming existing laboratory benchmarks. Implementation of the differential pressure method achieved high sensitivity in gas flux registration across a pressure range of up to 200 bar and thermal conditions spanning from −196 °C to +500 °C.
The metrological accuracy of the developed setup was validated through verification testing of standard DN40/PN40 size specimens. The obtained results exhibited excellent agreement with data from the reference Amtec TEMES fl.ai benchmark system across the entire operating pressure range.
The critical influence of the scale effect and assembly precision on the leak-tightness of flange seals was experimentally demonstrated. It was found that during the transition to larger diameters, assembly errors simulating flange misalignment lead to a substantial increase in the specific leak rate both at room temperature and under thermal extremes of −70 °C and +300 °C. This substantiates the necessity of implementing strain-gauge systems for real-time monitoring of stud tightening loads.
Methane evaluations at elevated pressures confirmed the molecular sieve effect inherent to the layered structure of multigraphene. At an operating pressure of 40 bar, the specific leak rate of methane was more than twofold lower than that of helium, demonstrating the high selectivity and superior barrier efficiency of the developed material toward hydrocarbon gases. Consequently, the developed instrumentation successfully bridges the gap between laboratory-scale gas permeability testing of advanced materials and the comprehensive evaluation of large-diameter flanged seal operational reliability under real process methane media.
Author Contributions
Conceptualization, V.A. and S.C.; methodology, D.D., I.N., K.K., and A.G.; software, V.G. and I.N.; validation, D.D. and N.M.; investigation, N.M., V.S., K.K., and A.G.; resources, V.S.; writing—original draft preparation, D.D. and V.A.; writing—review and editing, S.C.; visualization, N.M., V.S., and V.G.; supervision, S.C. All authors have read and agreed to the published version of the manuscript.
Funding
The study was supported by the state assignment of Lomonosov Moscow State University, project No. AAAA-A21-121011590086-0.
Data Availability Statement
The data presented in this study are available on request from the corresponding author.
Conflicts of Interest
The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analysis, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.
References
- Bouzid, A.-H.; Khelil, A. Comparison of Stresses in the Junctions of Shell Structures with Bolted Flange Rings. Int. J. Press. Vessels Pip. 2026, 219, 105660. [Google Scholar] [CrossRef] [Scilit]
- Cai, L.; Lu, Y.; Zhang, L.; Zhang, W.; Huang, W.; Liu, J.; Liu, Y.; Lai, C.; Liu, K.; Li, Y. Leak tightness tests of mechanical seal joints for HL-2M tokamak under thermal cycle loads. Vacuum 2023, 218, 112614. [Google Scholar] [CrossRef] [Scilit]
- Garcinuño, B.; Malo, M.; Patiño, J.; Arranz, F.; Fernández-Berceruelo, I.; Jiménez-Rey, D.; Navas, J.; García, J.M.; Rapisarda, D. Hydrogen injection into liquid PbLi for fusion applications: Fabrication and commissioning. Int. J. Hydrogen Energy 2025, 112, 503–510. [Google Scholar] [CrossRef] [Scilit]
- Schmidt, K.; Podmore, I. Current Challenges in Volatile Organic Compounds Analysis as Potential Biomarkers of Cancer. J. Biomark. 2015, 2015, 981458. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gui, C.; Li, G.; Zhu, R.; Lei, Z.; Dong, Y. Capturing VOCs in the pharmaceutical industry with ionic liquids. Chem. Eng. Sci. 2022, 252, 117504. [Google Scholar] [CrossRef] [Scilit]
- Kim, Y.; Lee, J.; An, N.; Kim, J. Advanced natural gas liquefaction and regasification processes: Liquefied natural gas supply chain with cryogenic carbon capture and storage. Energy Convers. Manag. 2023, 292, 117349. [Google Scholar] [CrossRef] [Scilit]
- He, T.; Si, B.; Gundersen, T.; Chen, L.; Lin, W. Integrated ethane recovery and cryogenic carbon capture in a dual mixed refrigerant natural gas liquefaction process. Energy 2024, 290, 130125. [Google Scholar] [CrossRef] [Scilit]
- Clarke, J.; Ren, Z.; Dettmer, W.; Zhang, W. Liquefaction phenomena in under-expanded cryogenic hydrogen gas jets. Phys. Fluids 2025, 37, 056111. [Google Scholar] [CrossRef] [Scilit]
- Liukonen, L.B.; Weir, F.W. Asbestos exposure from gaskets during disassembly of a medium duty diesel engine. Regul. Toxicol. Pharmacol. 2005, 41, 113–121. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Cheng, R.T.; McDermott, H.J. Exposure to Asbestos from Asbestos Gaskets. Appl. Occup. Environ. Hyg. 1991, 6, 588–591. [Google Scholar] [CrossRef] [Scilit]
- Gibbons, W. The Exploitation and Environmental Legacy of Amphibole Asbestos: A Late 20th Century Overview. Environ. Geochem. Health 1998, 20, 213–230. [Google Scholar] [CrossRef] [Scilit]
- Amenta, F.; Bolelli, G.; Pedrazzi, S.; Allesina, G.; Santeramo, F.; Bertarini, A.; Sassatelli, P.; Lusvarghi, L. Sliding wear behaviour of fibre-reinforced PTFE composites against coated and uncoated steel. Wear 2021, 204097, 486–487. [Google Scholar] [CrossRef] [Scilit]
- Xiao, J.; Nie, Z.; Wang, Z.; Du, Y.; Tang, E. Energy release behavior of Al/PTFE reactive materials powder in a closed chamber. J. Appl. Phys. 2020, 127, 165106. [Google Scholar] [CrossRef] [Scilit]
- Sheetz, B.S.; Dwyer, J.R. Probing nanopore surface chemistry through real-time measurements of nanopore conductance response to pH changes. Rev. Sci. Instrum. 2023, 94, 104101. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, P.-C.; Chen, M.-H.; Jenkinson, J.; Song, Y.-X.; Sun, L. Interfacial friction effects on sealing performances of elastomer packer. Pet. Sci. 2024, 21, 2037–2047. [Google Scholar] [CrossRef] [Scilit]
- Conway, K.M.; Pataky, G.J. Aramid Fiber Surface Area Impact on Elastomer Crack Growth. Exp. Mech. 2022, 62, 1647–1654. [Google Scholar] [CrossRef] [Scilit]
- Davtyan, A.; Isunts, H.; Azizov, A.; Avagyan, V. Comprehensive overview of materials, sealing methods and vulnerabilities of UHV systems for particle accelerators. J. Instrum. 2025, 20, T03002. [Google Scholar] [CrossRef] [Scilit]
- Pérez-Ràfols, F.; Larsson, R.; Almqvist, A. Modelling of leakage on metal-to-metal seals. Tribol. Int. 2016, 94, 421–427. [Google Scholar] [CrossRef] [Scilit]
- Li, H.-Y.; Yu, Y.; Liu, L.; Liu, L.; Wu, Y. One-step electrochemically expanded graphite foil for flexible all-solid supercapacitor with high rate performance. Electrochim. Acta 2017, 228, 553–561. [Google Scholar] [CrossRef] [Scilit]
- Li, Y.; Fu, Z.; Xue, M.; Shao, Z.; Li, Y.; Zhu, Q. Experimental study on preparation and thermal storage properties of expanded graphite/paraffin wax as a shape-stabilized phase change material. Energy Rep. 2022, 8, 324–331. [Google Scholar] [CrossRef] [Scilit]
- Hou, B.; Sun, H.-J.; Peng, T.-J.; Zhang, X.-Y.; Ren, Y.-Z. Rapid preparation of expanded graphite at low temperature. New Carbon Mater. 2020, 35, 262–268. [Google Scholar] [CrossRef] [Scilit]
- Wang, Y.; Fan, J.; Jiang, H.; Wang, S. Study on the sealing performance of high-pressure flanges by a magnetic measurement method of bolt axial force. Measurement 2024, 236, 114853. [Google Scholar] [CrossRef] [Scilit]
- Jaszak, P. Prediction of the durability of a gasket operating in a bolted-flange-joint subjected to cyclic bending. Eng. Fail. Anal. 2021, 119, 105027. [Google Scholar] [CrossRef] [Scilit]
- Ambjørner, H.R.; Bjørnlund, A.S.; Bonczyk, T.G.; Dollekamp, E.; Kaas, L.M.; Colding-Fagerholt, S.; Mølhave, K.S.; Damsgaard, C.D.; Helveg, S.; Vesborg, P.C.K. Thermal dynamics of few-layer-graphene seals. Nanoscale 2023, 15, 16896–16903. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Chaitoglou, S.; Spachis, L.; Zisis, G.; Raptis, I.; Papanikolaou, N.; Vavouliotis, A.; Penedo, R.; Fernandes, N.; Dimoulas, A. Layer-by-layer assembled graphene coatings on polyurethane films as He permeation barrier. Prog. Org. Coat. 2021, 150, 105984. [Google Scholar] [CrossRef] [Scilit]
- Wang, X.; Lin, H.; Bi, H.; Cao, Q.; Meng, D.; Sun, L.; Ren, G.; Qi, J.; Zhang, J. New leak element based on transfer-free single-layer graphene membrane. Vacuum 2022, 195, 110681. [Google Scholar] [CrossRef] [Scilit]
- Gracheva, A.V.; Klyukova, K.E.; Makhina, V.S.; Morozov, N.S.; Konstantinov, M.S.; Filippova, M.S.; Semenyako, D.M.; Chebotarev, S.N.; Avdeev, V.V. Impact of Natural Spheronized Graphite Structure on Lithium-Ion Performance. J. Electrochem. Soc. 2025, 172, 110542. [Google Scholar] [CrossRef] [Scilit]
- Darabut, A.M.; Lobko, Y.; Yakovlev, Y.; Rodríguez, M.G.; Veltruská, K.; Šmíd, B.; Kúš, P.; Nováková, J.; Dopita, M.; Vorokhta, M.; et al. Influence of thermal treatment on the structure and electrical conductivity of thermally expanded graphite. Adv. Powder Technol. 2022, 33, 103884. [Google Scholar] [CrossRef] [Scilit]
- Nigmatullin, I.; Morozov, N.; Olshukov, A.; Shulyak, V.; Gubin, V.; Klyukova, K.; Gracheva, A.; Avdeev, V.; Chebotarev, S. Influence of Manufacturing Factors on Mechanical Behavior of Sealing Multigraphene Materials. J. Mater. Eng. Perform. 2026, 35, 27775–27785. [Google Scholar] [CrossRef] [Scilit]
- Wang, X.L.; Li, B.; Qu, Z.G.; Zhang, J.F.; Jin, Z.G. Effects of graphite microstructure evolution on the anisotropic thermal conductivity of expanded graphite/paraffin phase change materials and their thermal energy storage performance. Int. J. Heat Mass Transf. 2020, 155, 119853. [Google Scholar] [CrossRef] [Scilit]
- Shulyak, V.A.; Morozov, N.S.; Gracheva, A.V.; Gritskevich, M.D.; Chebotarev, S.N.; Avdeev, V.V. Anisotropy of Electrical and Thermal Conductivity in High-Density Graphite Foils. Nanomaterials 2024, 14, 1162. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Jaszak, P. Modeling of the elastic properties of compressed expanded graphite—A material used in spiral wound gaskets. Int. J. Press. Vessels Pip. 2020, 187, 104158. [Google Scholar] [CrossRef] [Scilit]
- Grine, L.; Bouzid, A. Analytical and Experimental Studies of Liquid and Gas Leaks through Micro and Nano-Porous Gaskets. Mater. Sci. Appl. 2013, 4, 32–42. [Google Scholar]
- Sakamoto, S.; Azami, T.; Nitta, I.; Tsukiyama, Y. Fundamental study of acoustic leakage through a gap between gasket and flange surface. J. Adv. Mech. Des. Syst. Manuf. 2016, 10, JAMDSM0067. [Google Scholar] [CrossRef] [Scilit][Green Version]
- Shulyak, V.A.; Morozov, N.S.; Minushkin, R.A.; Klyukova, K.E.; Gubin, V.Y.; Gracheva, A.V.; Chebotarev, S.N.; Avdeev, V.V. Effect of intermolecular explosion on thermal conductivity in multi-graphene structures. Appl. Phys. Lett. 2025, 126, 242202. [Google Scholar] [CrossRef] [Scilit]
- Gubin, V.Y.; Vakhrushin, D.V.; Morozov, N.S.; Shulyak, V.A.; Gracheva, A.V.; Klyukova, K.E.; Avdeev, V.V.; Chebotarev, S.N. Approach and setup to measure high thermal conductivity in multigraphene materials. Rev. Sci. Instrum. 2026, 97, 034901. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Shulyak, V.A.; Morozov, N.S.; Makhina, V.S.; Klyukova, K.E.; Gracheva, A.V.; Chebotarev, S.N.; Avdeev, V.V. Intercalation of Large Flake Graphite with Fuming Nitric Acid. C 2024, 10, 108. [Google Scholar] [CrossRef] [Scilit]
- Levitz, P. Knudsen diffusion and excitation transfer in random porous media. J. Phys. Chem. 1993, 97, 3813–3818. [Google Scholar] [CrossRef] [Scilit]
- Fakher, X.S.; Khlaifat, A. Real-Gas Corrected Knudsen-Based Flow Regime Mapping of Methane in Nanoporous Media: Sensitivity, Validity Limits, and Engineering Implications. Gases 2026, 6, 31. [Google Scholar] [CrossRef] [Scilit]
- Guo, X.W.; Zhao, J.; Wang, G.; Fang, M.; Zhu, K. Effect of Pore-Scale Anisotropic and Heterogeneous Structure on Rarefied Gas Flow in Three-Dimensional Porous Media. Fluids 2025, 10, 175. [Google Scholar] [CrossRef] [Scilit]
- Yu, S.; Ameel, T.A. Slip-flow heat transfer in rectangular microchannels. Int. J. Heat Mass Transf. 2001, 44, 4225–4234. [Google Scholar] [CrossRef] [Scilit]
- Greenwood, J.A.; Putignano, C.; Ciavarella, M. A Greenwood & Williamson theory for line contact. Wear 2011, 270, 332–334. [Google Scholar] [CrossRef] [Scilit]
- Cloostermans, B.; Pronk, D.; Bruckenburg, B.; Goossens, S.; Baghdasaryan, T.; Berghmans, F. Bolted Flange Connection Leakage: A Systematic Review of Monitoring Challenges and Technologies. IEEE Sens. Rev. 2025, 2, 1–16. [Google Scholar] [CrossRef] [Scilit]
- Cheng, X.H.; Xue, W.H.; Zheng, G.M.; Wang, S.J.; Xu, B.S.; Wang, J.X. Study on the Tribological Behavior and the Interaction between Friction and Oxidation of Graphite Reinforced by Impregnated Phosphate at High Temperatures. Materials 2023, 16, 3517. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Han, H.S.; Hwang, S. Numerical simulation of leakage rate through bolted flanged joints with non-linear gasket deformation. Int. J. Press. Vessels Pip. 2017, 150, 74–84. [Google Scholar]
- Xu, X.Z.; Xu, L.J.; Sun, J.F.; Liu, M.H.; Liao, T.H.; Hu, X.P. Research on Micro Gap Flow Field Characteristics of Cylindrical Gas Film Seals Based on Experimental and Numerical Simulation. Aerospace 2024, 11, 40. [Google Scholar] [CrossRef] [Scilit]
- Sun, P.Z.; Yagmurcukardes, M.; Zhang, R.; Kuang, W.J.; Lozada-Hidalgo, M.; Liu, B.L.; Cheng, H.-M.; Wang, F.C.; Peeters, F.M.; Grigorieva, I.V.; et al. Exponentially selective molecular sieving through angstrom pores. Nat. Commun. 2021, 12, 7170. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |