Skip to Content
BatteriesBatteries
  • Article
  • Open Access

2 September 2026

33 Pages

Human-Guided AI Development of Physics-Bounded Screening Rules for Sparse Battery Signals: A LiFePO4 Case Study

,
,
,
,
and
1
Department of Civil Engineering, Tennessee State University, Nashville, TN 37209, USA
2
EcoC2S, Nashville, TN 37206, USA
3
Department of Mechanical Engineering, Tennessee State University, Nashville, TN 37209, USA
4
Office of the Chancellor, Elizabeth City State University, 1704 Weeksville Road, Elizabeth City, NC 27909, USA

Abstract

Battery-management systems observe current, terminal voltage, limited temperature measurements, and operating setpoints, but not the internal variables of electrochemical theory, so routine signals generally cannot identify a unique mechanism. We present a human-guided, generative-AI-assisted methodology that translates physics-based expectations into deterministic, auditable screening rules: human scientific authority fixes the physical assumptions, evidence requirements, and permissible claims, artificial intelligence supports development, and runtime evaluation is non-generative. LiFePO4 is the test case. A Zeng–Bazant current-dependent plateau approximation supplies a physics-based reference, and a bivariate representational precedent motivates a composite, reference-dependent voltage residual that is not identified as thermodynamic work. Eleven observable screens return present, absent within resolution, indeterminate, or unavailable. Four evidence forms are separated. Digitized model curves show the reduced plateau relation tracks its parent phase-field simulation through moderate rates, with a high-rate limitation. Published temperature-conditioned discharge profiles show stable plateau elevation and flattening from 268 to 298 K across 0.5 C–2 C, with mixed 2 C curvature. Measured replicates of a commercial cylindrical cell at two ambient setpoints resolve a within-run surface-temperature depression whose integrated first-law balance is heat-rejection-dominant and compatible with, but not uniquely attributed to, a literature-bounded reversible contribution. Controlled synthetic cases verify deterministic feature recovery and abstention without establishing a mechanism.

1. Introduction

1.1. Artificial Intelligence in a Partially Observed Battery System

Artificial intelligence is used in battery research for state or parameter estimation and fault diagnosis [1,2]. Large-language-model (LLM)-assisted fault-diagnosis work in process systems provides adjacent methodological context [3]. A generative system used to help formulate scientific rules presents a distinct problem: plausible language does not establish that a relationship is physically observable, uniquely identifiable, or supported by the available evidence.
Electrochemical theory contains internal concentration, potential, reaction-current, phase-boundary, and heat-generation variables [4,5,6,7,8]. Practical battery-management-system (BMS) records are typically limited to current, terminal voltage, available temperature measurements, and operating metadata; this study treats that inventory as its declared observation model. Because several internal processes can produce similar terminal signatures and can act simultaneously, sparse measurements do not generally identify a unique mechanism without additional measurements, controlled perturbations, or independently validated model structure [1,9,10,11,12,13].
The practical question is therefore narrower: given a sparse record, an elected physical reference, declared limits, and candidate explanations, what can be stated without converting an assumption into an observation? Physics constrains admissible interpretations; it does not make hidden states observable.

1.2. Two Sides of the Scientific Thesis

The manuscript has two commitments. Physical claims retain their equations, assumptions, parameter provenance, reference states, and appropriate evidence. Operational inference is limited to what the measured record can support. These commitments are mutually necessary: physics prevents an observable rule from acquiring an unsupported interpretation, while sparse-signal reasoning preserves measured structure without pretending to reconstruct hidden states.
Human scientific authority selects the question, models, assumptions, evidence requirements, and final claims; generative AI assists development and critical examination; and after the specification is fixed, runtime evaluation is deterministic and non-generative. Cross-domain studies likewise combine human approval with deterministic rule components, expert orchestration, or supervisory separation [14,15,16,17,18,19,20]. This article documents a bounded workflow, not a comparison showing it superior to human-only or AI-only development.

1.3. LiFePO4 Plateau Physics as the Methodological Test Case

LiFePO4 provides a demanding test case because its extended plateau is physically structured but does not make internal phase behavior directly observable from terminal voltage [8,21,22]. The Zeng–Bazant phase-field model and its reduced plateau relation provide the qualified current-conditioned reference used here, with the assumptions, values, coordinate distinctions, and high-rate limitation retained in Section 4. Digitized source curves qualify the approximation within its model family; they do not experimentally validate the rule system.

1.4. From a Two-Coordinate Precedent to an Operational Voltage Residual

The Gemmer–Michel–Mahler bivariate formulation and first-law screening precedent supply a limited representational basis for separating an equilibrium-related coordinate from a driven departure [23,24]. Here, terminal voltage is represented against an elected plateau reference, and the difference is retained as a composite, reference-dependent voltage residual. The precedent supplies neither a battery constitutive law nor a thermodynamic-work interpretation; Section 4 defines the construction and its limits.

1.5. Observable Rules and Calibrated Abstention

The authors’ specification uses an eligibility gate and eleven observable screens to evaluate declared comparisons rather than issue mechanism verdicts. Each rule returns present, absent within resolution, indeterminate, or unavailable, and the combined report preserves agreement, conflict, layering, insufficiency, and unexplained behavior. This design is informed by qualitative and model-based diagnosis, including candidate-set reasoning, multiple-fault diagnosis, and multiple-valued residual evaluation [9,10,11,12,13].

1.6. Evidence Strategy

The study separates four evidence forms. These are published Zeng–Bazant model curves, which qualify the reference within a model regime; published measured electrode profiles, which support one external measured-data R9 application; published measured cylindrical-cell replicate records carrying synchronized electrical and surface-temperature channels, which support one external measured-data R8 application; and controlled synthetic records, which check deterministic feature recovery and abstention [21,25,26].

1.7. Contributions and Boundaries

This article (1) formulates battery reasoning as physics-bounded inference under partial observability; (2) documents a human-guided, generative-AI-assisted development process with deterministic runtime; (3) connects a current-conditioned LiFePO4 plateau reference to a composite voltage residual; (4) specifies G0, R1–R11, four local states, and combined outcomes; and (5) separates model-curve qualification, two measured-data applications, and controlled synthetic implementation checks.
The evidence boundary of these contributions is stated explicitly. The residual is a composite, reference-dependent observable rather than thermodynamic work; a macroscopic plateau coordinate is a bookkeeping coordinate rather than a microscopic filling measurement; terminal voltage is reported as a composite signal and is not uniquely decomposed; experimental application covers two rules rather than all eleven; diagnostic error rates are not calibrated; and deployment readiness and AI-development efficacy lie outside the reported evidence. Thermal conclusions are bounded to one measured within-run surface-temperature application. Section 7 states the limitations authoritatively, and Section 7.9 defines the next validation stage.

1.8. Organization of the Paper

Section 2 defines the development process and the deterministic-release boundary, Section 3 the study objects and evidence, and Section 4 the physical reference and the lumped energy-domain identity. Section 5 gives the human-readable G0/R1–R11 interface, Section 6 the measured R9 and R8 applications and the synthetic checks, and Section 7 and Section 8 the bounded contribution and validation program. Appendix A indexes the complete Supplementary Materials S1–S3 package.

2. Human-Guided AI Development and Deterministic Execution

2.1. Purpose of the Human–AI Method

The method is a development process, not a runtime battery-control architecture. It translates a physically rich but partially observed description into explicit questions that can be evaluated from sparse signals. Generative AI assists construction, challenge, calculation, and documentation; human scientific authority determines physical admissibility, evidence requirements, and permissible claims.
The process has two regimes. Development is iterative and generative: alternatives may be proposed, rejected, or revised. Execution begins only after the observable, required inputs, reference, preprocessing, thresholds, sensitivity conditions, and output states are fixed. The runtime evaluator is deterministic and never uses a language model to assign a result.

2.2. Human Scientific Authority

The human author retains authority over the scientific question; the physical model and assumptions; the admissible observables and reference; evidence requirements; rule acceptance, abstention conditions, and thresholds; and the final scientific claims. The review must determine whether each proposed quantity is measured, calculated from a declared reference, reference-dependent, or affected by unobserved contributions, because non-unique mappings require correspondingly narrow output language.

2.3. AI-Supported Development Functions

In this case study, AI assisted literature comparison, candidate formulation, counterexample and confounder generation, calculation and software support, adversarial consistency checking, and documentation: comparing source relations, testing whether wording implied direct observability or physical validation, enumerating alternatives to voltage and temperature features, inspecting calculations, and reconciling equations, prose, figures, captions, and software variables. These functions were development support, not autonomous scientific judgment; AI did not select the final interpretation, approve a rule, or decide that the evidence was sufficient.

2.4. Iterative Development Cycle

The development cycle was as follows: (1) the human states a diagnostic question; (2) AI produces candidate formulations, assumptions, observables, and alternatives; (3) the human rejects or modifies candidates that exceed the interpretation; (4) accepted candidates become explicit inputs, transformations, eligibility conditions, and outputs; (5) calculations or controlled tests expose inconsistencies; and (6) the human accepts, revises, retains as prospective, or removes the rule.
The cycle is not an optimizer or a convergence claim; its stopping condition is a human decision that a rule has a clear observable, declared assumptions, known confounders, reproducible implementation, and bounded output. A definition or analysis window changed after inspecting external data makes that dataset development evidence for the revised rule rather than an independent challenge. The detailed decision records are retained in Supplementary Materials S3 and indexed in Appendix A.

2.5. Transition from Generative Development to a Fixed Specification

A rule becomes executable when its required channels and metadata, reference and provenance, coordinate and branch convention, preprocessing, interval, reporting floor, feature definition, eligibility conditions, sensitivity perturbations, local states, and combined-report logic are fixed. After this release, the evaluator cannot select a favorable window, alter a threshold, reinterpret a branch, or replace a missing channel; such a change creates a new specification version.
The fixed scientific specification and deterministic implementation together are the reproducible object. The implementation boundary distinguishes missing evidence (unavailable), unresolved features in eligible data (absent within resolution), and sensitivity-conflicted calculations (indeterminate).

2.6. Deterministic Runtime Evaluator

At release, identical records and fixed configurations produce identical states, observables, and flags. G0 and the scientific interface in Section 5 govern eligibility and output semantics; Supplementary Materials S1 contains the normative executable details. The evaluator accepts only the released record and configuration, applies fixed transformations and decision logic, and does not invoke a language model.

2.7. Auditability and Reproducibility

Each reported result identifies its input data, branch, elected reference, interval, preprocessing, thresholds, resolution floor, sensitivity conditions, calculated features, and state. The artifacts indexed in Appendix A support deterministic reproduction and partial auditability of the development process. The retained record covers the released specification and its decision points rather than every discarded conversational branch or informal judgment, and software tests establish conformance to declared operations, with validation of the motivating physical assumptions reported separately as evidence.

2.8. What the Case Study Establishes

The case study establishes a documented way to use generative AI within human-controlled physical, evidentiary, and runtime boundaries. Optimality, efficiency, accuracy, creativity, reliability, and comparative superiority of the workflow lie outside this evidence: those questions are answered by independent developers, fixed tasks, predefined metrics, and controlled comparison, which the next validation stage identifies.

3. Study Design, Evidence, and Interpretation

3.1. Study Objective and Units of Evaluation

The study asks whether a physics-bounded rule framework can organize sparse battery records without assigning unsupported physical specificity. It evaluates distinct objects rather than one global classifier. The objects are the model-consistency of the Zeng–Bazant reference; the observability and boundedness of the rule architecture; an external measured-data R9 voltage-geometry application; a measured-data R8 within-run surface-temperature-geometry application on replicate cylindrical-cell records; deterministic implementation behavior on synthetic records; and the documented human–AI development process. The latter is descriptive and is not an efficacy comparison. Table 1 summarizes the study objects, evidence sources, and permitted conclusions.
Table 1. Study objects, evidence sources, and permitted conclusions.
Success for one object is not evidence for another: model-to-model agreement does not validate a full-cell rule, synthetic recovery does not identify a physical process, and two measured-data applications do not establish all eleven screens.

3.2. Evidence Sources

3.2.1. Published Zeng–Bazant Model Curves

Published numerical phase-field model output and the reduced analytical relation from Zeng and Bazant [21] were digitized with independently calibrated axes. The values are the authors’ digitization analysis with extraction uncertainty, not experimental cell data. See Table 1 above. Their purpose is to test the current-conditioned reference against its parent model while retaining filling-coverage limitations.

3.2.2. Published Temperature-Conditioned Discharge Profiles

The Ombrini et al. open electrochemical dataset [25,26] supplies measured electrode profiles for a 1 mAh cm−2 LiFePO4 electrode at declared test-temperature conditions of 268, 283, and 298 K and nominal 0.5 C, 1 C, and 2 C, with the source defining 1 C as 1 mA cm−2. The source provides no synchronized measured cell T ( t ) , chamber tolerance, or complete equilibration history, so the declared condition is used only as the matching condition for R9 voltage geometry and T c e l l ≈ T a m b is a limited working approximation, not a full-cell validation or an isothermal claim.
The primary window q = 0.10 – 0.35   m A h   c m − 2 was selected after inspection because all nine profiles contain it, and here q is an areal-capacity coordinate for the selected electrode records. This is an external measured-data development application, not a preregistered or held-out test, and it cannot support self-heating, heat-transfer, reversible-heat, thermal-time-constant, or within-run temperature-evolution claims.

3.2.3. Controlled Synthetic Records

Deterministic synthetic records deliberately contain or omit declared electrical and thermal features. They test feature extraction, sign handling, negative controls, and abstention under known generator conditions. They can establish generator-conditional implementation behavior, not physical specificity, calibrated thresholds for measured cells, or mechanism identification.

3.2.4. Measured Cylindrical-Cell Surface-Temperature and Voltage Records

A fourth evidence source is a set of published third-party galvanostatic discharge records for A123 Systems ANR26650M1-B cylindrical LiFePO4/graphite cells, identified in Section 6.9.1 and in the data availability statement. Six nominal replicates were recorded at each of two chamber setpoints, 25 °C and 35 °C, at a 1 C constant current, giving twelve records with synchronized current, terminal voltage, and can-surface temperature. The measured quantity T s u r f is the temperature of the cell can, distinct from the declared ambient chamber condition T a m b ; core temperature is not measured, and the surface-to-core offset is unresolved, so no core-temperature statement is made.
These twelve records are genuine nominal replicates of one cell model. Replicate agreement is therefore reported as a within-set reproducibility statement and not as a population confidence interval; six replicates of a single cell model do not license population language, and error rates and predictive values still require labeled ensembles. The earlier framing that measured curves are not treated as independent replicates remains scoped to the electrode-level discharge profiles used for the ambient-temperature voltage-geometry application. These records support an R8 within-run temperature-geometry evaluation and an integrated first-law consistency check; they do not support entropy measurement, heat-source identification, or a validated thermal model.

3.3. Sparse Records and Declared References

The minimum electrical record is D I V = { t , I ( t ) , V t e r m ( t ) } ; individual rules may require a measured temperature trajectory, setpoint, capacity coordinate, interruption marker, branch label, or matched record. Reference-dependent results identify the elected reference and provenance. A macroscopic coordinate organizes a reproducible observed interval; it does not assert a microscopic concentration event. Branch-dependent rules require an established sign convention and branch identity.

3.4. Eligibility Gate

G0 is defined authoritatively in Section 5. At study-design level, each requested rule must have its required channels, ordered coordinates, branch identity, reference, observed support, matched conditions, declared resolution/preprocessing/thresholds, and quantities needed by its interpretation. A failed requirement returns unavailable, not absent within resolution. This local decision prevents ambient labels from being substituted for measured T ( t ) and prevents unsupported curve segments from becoming inferred observations.

3.5. Rule-Local States and Combined Outcomes

Section 5 defines present, absent within resolution, indeterminate, unavailable, and the combined-report outcomes. In this study design, those labels describe the eligible observable screen, not the existence of a hidden mechanism or a calibrated probability.

3.6. Thresholds, Resolution, and Preprocessing

Thresholds are identified as instrument-derived, literature-derived, model-derived, calibrated on declared development data, or author-selected operational reporting floors. Resolution is recorded for each measured channel, and derived features inherit measurement and preprocessing uncertainty. Preprocessing, alignment, and common-support selection are fixed for an evaluation, and unsupported curve segments are not extrapolated.

3.7. Sensitivity and Uncertainty

The study distinguishes extraction or numerical uncertainty from uncertainty in physical interpretation. Repeated digitization quantifies extraction variability; nine nearby windows, declared preprocessing and alignment variants, and conditional moving-block residual resampling assess numerical and directional stability within a record [27]. Neither creates population confidence intervals nor resolves mechanism non-uniqueness. A component is directionally stable only when it retains sign across declared valid variants and exceeds its reporting floor. Section 6 states the configurations actually applied.

3.8. Implemented and Prospective Evaluations

Implemented work comprises Zeng–Bazant digitization; specification of G0/R1–R11 and their outcomes; the R9 application to the Ombrini profiles; the R8 application to measured replicate cylindrical-cell records at one rate and two ambient setpoints; controlled synthetic checks; and documentation of the human–AI and deterministic-runtime boundary. Rules requiring matched cooling-boundary contrasts, interruptions, charge–discharge pairs, memory protocols, or additional rate scans were not evaluated on the selected external records.
Prospective work is listed in Section 7.9. A specification or validation plan is not reported as completed evidence.

3.9. Interpretation Limits

Residuals remain reference-dependent constructed observables, not thermodynamic work or uniquely identified losses. Macroscopic plateau coordinates are not microscopic measurements, and observable features are not mechanism verdicts. Model-to-model comparison, the two measured-data applications, and the synthetic checks retain their separate evidentiary scopes.

4. Physical Reference and Observable Construction

4.1. LiFePO4 Plateau Physics and Assumptions

The operational reference is motivated by the phase-separating behavior of LiFePO4. In a phase-field description, the active material can separate into Li-poor and Li-rich regions joined by a diffuse interface. As transformation proceeds, the phase boundary moves while the bulk-phase compositions remain near stable values, so the diffusional chemical potential is approximately constant through most of the transformation interval and produces the characteristic voltage plateau [8,21,22,28].
Zeng and Bazant describe this behavior using a Cahn–Hilliard-reaction model for a spherical intercalation particle [21,28]. In dimensionless form, the chemical potential is
μ ~ = l n c ~ 1 − c ~ + Ω ~ ( 1 − 2 c ~ ) − κ ~ ∇ ~ 2 c ~ ,
where c ~ is the local filling fraction, Ω ~ is the regular-solution interaction parameter scaled by thermal energy, and κ ~ is the dimensionless gradient-penalty coefficient. The gradient term accounts for the energetic cost of a diffuse phase boundary, and the source model couples this thermodynamic description to generalized Butler–Volmer charge-transfer kinetics at the particle surface.
The analytical plateau approximation applies within a more restricted regime. The particle is assumed isotropic, spherical, strain-free, and electronically conducting; surface wetting is set to zero, and the compositions within each bulk phase are treated as approximately uniform, so the gradient-penalty contribution is neglected away from the diffuse interface. The stable phase compositions then approximately satisfy
μ ~ ≈ l n c ~ 1 − c ~ + Ω ~ ( 1 − 2 c ~ ) = 0 .
The zero here is a reference condition in the nondimensional model, not an absence of chemical potential in the physical system: under the stated assumptions, the homogeneous chemical-potential contribution is constant at the stable phase compositions and is absorbed into the elected reference potential.
The source model relates dimensionless surface overpotential, chemical potential, voltage, and reference voltage through
η ~ = μ ~ + V ~ − V ~ Θ .
At equilibrium, η ~ = 0 . At the homogeneous reference condition c ~ = 1 / 2 , the logarithmic and regular-solution terms both vanish, so the homogeneous chemical-potential contribution is zero relative to the chosen reference and V ~ = V ~ Θ . This defines the role of half filling in the source model: it is a local homogeneous reference, not a statement that a phase-separated particle or practical electrode becomes spatially uniform at half filling.
The analytical approximation also inherits limitations from the isotropic single-particle model: real LiFePO4 particles can exhibit anisotropic transport, orientation-dependent reaction activity, coherency strain, surface wetting, defects, and particle-to-particle heterogeneity [8,22], and a porous electrode additionally contains electrolyte polarization, electronic and contact resistance, negative-electrode response, and nonuniform current sharing [4,5,6,7]. These effects do not invalidate the source relation as a reference construction, but they prevent it from serving as a complete full-cell voltage model.

4.2. Zeng–Bazant Current-Conditioned Plateau Relation

For ion insertion into the phase-separating particle, with Butler–Volmer transfer coefficient α = 1 / 2 , Zeng and Bazant obtain the approximate discharge-plateau relation [21]
V p l Z B ( I ) ≈ V Θ − 2 k B T e s i n h − 1 I ^ 4 ( 1 − c ~ l ) .
Zeng and Bazant’s source plateau relation is reproduced here without carrying the source equation number into the manuscript equation sequence.
Here,
I ^ = I ~ I ~ 0 ( c ~ = 1 / 2 ) ,
where I ~ is the dimensionless applied insertion current and I ~ 0 ( c ~ = 1 / 2 ) the exchange current evaluated at the homogeneous half-filling reference. The composition c ~ l is the Li-rich stable surface-phase composition satisfying the homogeneous stable-phase condition; it is not equal to 1 / 2 .
Under the stated two-phase assumptions, the equilibrium-related contribution is contained in V Θ , while the current-conditioned departure appears through the inverse-hyperbolic-sine kinetic term. The relation is not a first-law decomposition of terminal voltage, and it does not enumerate every contribution present in a full cell.
The source authors compare this analytical relation with the plateau produced by the full numerical Cahn–Hilliard-reaction model. Figure 6 of Zeng and Bazant [21] shows charge and discharge voltage versus whole-particle mean filling at ± 1   C , ± 10   C , ± 100   C , and ± 1000   C ; Figure 7 of that source [21] compares the simulated discharge plateau with the analytical approximation for positive insertion current.
Digitization of the published figures provides two checks: whether the whole-particle midpoint is available and locally representative for the displayed charge and discharge branches, and how the analytical approximation compares with the numerical plateau over current. The two figures were calibrated independently because they have different axes and curve presentations. Reported uncertainties describe digitization, including axis calibration, line thickness, and local sampling dispersion; they are not model error bars or experimental confidence intervals.
Table 2 reports the visible charge and discharge branches at X = 0.5 and Table 2 shows the fit for the digitized Zeng—Bazant plateaus.
Table 2. Digitized Zeng–Bazant voltages at the whole-particle mean-filling midpoint (source figure [21]).
At 1 C, 10 C, and 100 C, the visible branches are sufficiently flat around X = 0.5 for the midpoint to serve as a representative local plateau comparison. At 1000 C, neither branch is available at the midpoint, so no midpoint voltage or gap is inferred.
Table 3 compares the digitized numerical discharge plateau with the analytical approximation over the available filling intervals.
Table 3. Digitized Zeng–Bazant numerical and analytical discharge-plateau comparison (source figure [21]). Plateau values are means over the sampled filling intervals X = 0.25–0.70 (1 C and 10 C), X = 0.20–0.75 (100 C), and X = 0.15–0.30 (1000 C). The 1000 C interval lies away from X = 0.5 because neither branch reaches the midpoint at that rate, which is why Table 2 reports the 1000 C midpoint as unavailable while a plateau mean over the available interval is still reported here.
The reduced relation tracks the numerical plateau within combined digitization uncertainty at 1 C, 10 C, and 100 C. At 1000 C, the difference slightly exceeds the combined digitization uncertainty and the numerical curve is strongly filling-dependent. The source relation is therefore used as a current-conditioned particle-model reference with an explicit high-rate limitation. This comparison does not establish experimental agreement or full-cell applicability.

4.3. Distinct Concentration and Capacity Coordinates

Four coordinates appear in the reference construction and must not be conflated.
Local homogeneous filling, c ~ = 1 / 2 . This is the local reference composition in the homogeneous source model. It defines V Θ and the exchange-current normalization used in I ^ .
Li-rich stable composition, c ~ l . This is the high-concentration root of the homogeneous stable-phase condition. It describes the approximate surface composition during insertion and enters the analytical plateau relation.
Whole-particle mean filling, X . Zeng and Bazant define
X = ∫ c   d V 4 3 π R p 3 c m ,
where R p is the particle radius and c m is the maximum site concentration. The condition X = 0.5 is a whole-particle average used to compare the displayed charge and discharge branches. It does not imply that the local field is uniformly one-half.
Operational macroscopic coordinate, z . For a measured cell or electrode record, a normalized capacity coordinate is obtained from Coulomb counting and mapped onto the observed plateau interval, and z r e f = 0.5 denotes the operational midpoint of that interval. Its relationship to X = 0.5 is an elected model-to-observation correspondence rather than a direct measurement of particle filling.
The mapping can be summarized as
c ~ = 1 / 2   →   V Θ   and   exchange-current   normalization ,
c ~ l   →   Li-rich   phase   composition   in   V p l Z B ( I ) ,
X = 0.5   →   representative   whole-particle   midpoint ,
z r e f = 0.5   →   operational   midpoint   in   the   measured   plateau   record .
This correspondence permits a practical plateau comparison without requiring microscopic observability. Intraparticle gradients, phase coexistence, particle-size distributions, orientation, and nonuniform current sharing remain unresolved by the macroscopic coordinate.

4.4. A Two-Coordinate Representational Precedent

The Gemmer–Michel–Mahler bivariate formulation and the first-law screening precedent provide limited bases for representing an equilibrium-related contribution and a driven departure as separate coordinates [23,24]. The present work applies that representational idea to terminal battery voltage: the equilibrium-related coordinate is supplied by an elected plateau reference, and the second coordinate records the departure of the measured terminal voltage from that reference.
The precedent is used at the level of representation only. It does not supply a battery constitutive equation, identify the second coordinate with thermodynamic work, or prove that the battery residual is reference-invariant. This limited use is sufficient for the present purpose. It preserves both the physical reference and the observed departure without requiring the departure to have one cause, so the rule system can evaluate how the departure changes with time, current, branch, temperature condition, and interruption while the residual retains its composite status.

4.5. Elected Reference and Composite Voltage Residual

Let V r e f ( z , I , T r e f ; P r e f ) denote a general elected voltage-reference object, where P r e f records the reference protocol and provenance. It can represent an open-circuit, quasi-equilibrium, or declared low-current reference; in a low-current special case I = I r e f is fixed by P r e f , and a Zeng–Bazant special case uses V p l Z B ( I ) . At the operational plateau midpoint,
V r e f , 1 / 2 = V r e f ( z r e f , I r e f , T r e f ; P r e f ) ,     z r e f = 0.5 .
The reference type, current conditioning, and provenance are reported with every result. An empirical low-current reference and a model-derived current-conditioned reference are different analytical choices and are not substituted without relabeling the result.
For a discharge branch, define the composite voltage residual
r V ( t ) = V r e f ( z ( t ) , I ( t ) , T r e f ; P r e f ) − V t e r m ( t ) .
Positive r V therefore means that the measured terminal voltage lies below the elected discharge reference. Charge and discharge branches are evaluated separately, with sign conventions stated before calculation.
Where an elected Butler–Volmer activation reference is available, define the excess residual
r e x ( t ) = r V ( t ) − η B V , r e f ( I ( t ) , z ( t ) , T r e f ) .
The two residuals answer different questions: r V measures departure from the complete elected voltage reference, and r e x the departure remaining after the specified activation-reference term is removed. Neither is directly measured independently of the elected reference, and neither is identified as thermodynamic work.
The observation model can be written
V t e r m ( t ) = V r e f ( z ( t ) , I ( t ) , T r e f ; P r e f ) − r V ( t ) .
Equation (4) is an operational identity once the reference and sign convention have been declared. It is not a first-law proof that terminal voltage contains only two physical processes.

4.6. Reference Dependence and Unresolved Full-Cell Contributions

The residual is a full-cell observable constructed from a measured terminal voltage and an elected reference. A bookkeeping expansion may be written as
r V =   r + + r − + r e l y t e + r c t + r o h m / c o n t a c t + r s h a r e + r t h e r m a l + r s e n s o r + r r e f e r e n c e + r o t h e r ,
where the terms denote positive-electrode departure, negative-electrode contribution, electrolyte polarization, charge-transfer departure, ohmic and contact losses, nonuniform current sharing, temperature-dependent effects, sensor error, reference-curve discrepancy, and unenumerated contributions. The signs and exact grouping depend on the voltage convention and reference model.
Equation (5) is not an identifiable decomposition from the available terminal record, and the framework does not independently estimate its terms. It records the contributors that may remain inside the composite residual and therefore limits the interpretation of residual features.
Reference dependence enters in two ways. First, changing V r e f changes the residual directly. Second, a model-derived reference carries the assumptions and omitted processes of that model: a low-current empirical reference may include effects that a single-particle analytical relation excludes, while the analytical relation may provide current conditioning unavailable in a single empirical curve. Results are therefore reported with the reference choice and, where possible, repeated under alternative admissible references.
The residual may also preserve contributions from both electrodes. A positive-electrode particle model does not by itself isolate positive-electrode behavior in a full-cell terminal voltage: negative-electrode potential, lithium-metal counter-electrode polarization in half-cell data, electrolyte transport, series resistance, and contact effects remain unless independently removed or measured [4,5,6,7].
Temperature produces another non-unique contribution. An ambient label can condition a voltage comparison, but a rule requiring T ( t ) needs a measured temperature trajectory. A voltage difference across ambient conditions can reflect kinetics, electrolyte transport, resistance, capacity access, and thermal boundary effects [4,5,6,7,29]; it cannot be assigned uniquely to heat generation or cooling from voltage geometry alone.
These unresolved terms define the alternatives against which rule outputs are interpreted. A resolved residual feature can support a candidate relative to declared alternatives, but it does not isolate one term in Equation (5).

4.7. First-Law Energy-Domain Identity for a Lumped Surface Temperature

Equation (4) is a voltage-domain bookkeeping identity. This subsection states a separate energy-domain identity for a lumped surface-temperature description; neither identity validates the other, and the energy-domain form is not a first-law proof about the composition of terminal voltage. Let θ q = T s u r f q − T 0 denote the measured surface departure of the can-surface temperature from T0, the measured pre-discharge baseline of that record, C t h an effective heat capacity, H an effective heat-rejection coefficient, and q = I t the charge passed at constant current. With the discharge-positive convention I > 0 , the lumped balance is
C t h d θ d t = I E e q − V − T ∂ E e q ∂ T − H θ
where E e q is the equilibrium potential of the elected reference, V the terminal voltage, and T ∂ E e q ∂ T the voltage-equivalent reversible term. Writing the voltage-equivalent forcing as g q = E e q q − V q − T q ∂ E e q ∂ T and integrating between two charge coordinates gives
C t h θ q b − θ q a = ∫ q a q b g q d q − H / I ∫ q a q b θ q d q
At an extremum of the surface departure, d θ d q = 0 implies g = H / I θ . Over an interval on which the surface departure decreases, heat rejection exceeds internal generation in the integrated balance; that statement concerns an integrated balance and does not imply negative instantaneous internal heat generation. Equations (6) and (7) constrain signs and integrated balances only. They contain no fitted parameters, identify no microscopic heat source, and do not make Equation (5) identifiable, because the reversible term here is an externally bounded energy-domain quantity rather than an estimate of the r t h e r m a l term of Equation (5).

4.8. Operational Reference Logic and Handoff to the Screens

The reference construction identifies the measured branch and observed interval, maps it onto z , assigns z r e f = 0.5 where relevant, and documents the reference type, source, temperature, current conditioning, and assumptions. It then calculates r V ( t ) , and r e x ( t ) only where an activation reference is justified, retaining branch, rate, declared condition, resolution, preprocessing, and reference-sensitivity metadata before passing declared observables to R1–R11.
The screens operate on observable properties rather than on the individual terms in Equation (5): residual sign and magnitude, relaxation after current interruption, charge–discharge asymmetry, rate dependence, plateau level, slope, curvature, temperature-trajectory geometry, ambient-temperature interaction, electrical–thermal correlation, and response to controlled cooling.
Each screen inherits the assumptions and availability limits of the reference construction. A midpoint screen is unavailable if the branch does not reach the declared midpoint; a thermal-trajectory screen is unavailable without measured T ( t ) , a reference-dependent result remains labeled with its reference, and a feature that changes state across admissible references is reported as reference-sensitive or indeterminate.
Section 5 defines the eligibility conditions and R1–R11 screens that operate on these quantities. The physical reference constrains what the rules may ask; the sparse record constrains what they may answer.

5. Human-Readable Interface to the Rule Specification

5.1. Purpose and Division Between Article and Backend

The rule system is presented at two levels. This section provides the human-readable scientific interface: the information supplied to the evaluator, the eligibility decision, the question asked by each rule, the observable returned, and the interpretation boundary. Supplementary Materials S1 provides the executable detail, including equations, preprocessing, windows, thresholds, sensitivity perturbations, confounder checks, code-function mappings, and tests.
The two levels describe the same rule system. A rule is fully defined only when its scientific interface and technical specification agree; any discrepancy among prose, equations, and code must be resolved before reporting a result. This separation of observable residual features from mechanism assignment is consistent with qualitative and model-based diagnosis practice [9,10,11,12,13].

5.2. Rule Interface

For rule R j , the logical interface is
R j ( D , C j ) → s j , y j , f j ,
where
  • D is the measured record and associated metadata;
  • C j is the fixed configuration for rule j ;
  • s j is the rule-local state;
  • y j contains calculated observable values and units; and
  • f j records eligibility, resolution, sensitivity, and confounder flags.
The configuration identifies the elected reference, sign convention, required channels, evaluation interval, preprocessing, thresholds, reporting floors, and sensitivity variants; these are inputs to the rule rather than values selected during execution.
Every rule returns its calculated observables even when the final local state is indeterminate, provided the calculation itself is eligible, so a mixed result is not reduced to an uninformative label. If eligibility fails, the unavailable state is returned together with the failed requirement.

5.3. Eligibility Gate G0

The common eligibility gate, G0, runs before any R1–R11 evaluation. It does not decide whether a feature is present; it decides whether the requested rule can be interpreted from the supplied record and configuration.
G0 checks:
  • Presence and units of required measurement channels;
  • Ordering and coverage of time, capacity, or state coordinates;
  • Branch and current-direction identification;
  • Reference type, source, and applicability;
  • Common observed support for matched comparisons;
  • Current, temperature, loading, or cooling-condition matching;
  • Declared resolution, thresholds, and preprocessing; and
  • Availability of every quantity required by the rule’s interpretation.
The gate is local to the requested rule. An ambient-temperature label can satisfy G0 for R9 but cannot satisfy a measured-temperature-trajectory requirement for R8, and a discharge curve can support a plateau-geometry screen while remaining ineligible for a charge–discharge asymmetry screen. G0 also prevents extrapolation from being treated as observation: if one curve ends before the declared comparison window, the missing segment is not generated from a fitted model, and the matched comparison is unavailable or support-sensitive.

5.4. Rule Families and Observable Questions

The eleven rules are grouped by the type of comparison they require. Table 4 gives the main-text interface; full equations and decision logic are provided in Supplementary Materials S1. The rule names identify the observable comparison rather than a mechanism verdict: a rule can be relevant to several candidate mechanisms, and one candidate may require evidence from several rules. This many-to-many relationship is preserved in the combined report.
Table 4. Human-readable interface to the G0 and R1–R11 rule system.

5.5. Rule-Local States

The state s j returned by each rule is one of four values:
  • Present: The declared feature is resolved beyond the reporting floor and remains stable under required sensitivity checks;
  • Absent within resolution: The rule is eligible, but the declared feature is not resolved under the stated measurement and analysis limits;
  • Indeterminate: The calculation is eligible, but opposing components, confounders, alignment, reference choice, or sensitivity prevent a stable local statement; or
  • Unavailable: One or more required channels, metadata elements, references, matched conditions, or support intervals are missing.
The same state vocabulary applies across all rules, but the observable and eligibility requirements remain rule-specific. Present for R6 means that a declared geometric feature is resolved; present for R8 means that a declared measured-temperature trajectory feature is resolved. Neither state alone identifies a physical mechanism.
The result object retains the reason for an indeterminate or unavailable state—for example, inadequate common support, missing branch identity, reference sensitivity, threshold crossing under window perturbation, missing measured T ( t ) , unmatched current, or incomplete cooling metadata—so the reason guides the next measurement or protocol rather than disappearing into a generic failure label.

5.6. Deterministic Execution Sequence

The released evaluator applies G0, fixed transformations, declared calculations, sensitivity variants, and local-state logic without selecting favorable windows or thresholds, under the deterministic runtime boundary of Section 2. Supplementary Materials S1 supplies the complete executable sequence and test fixtures.

5.7. Combined Report

The combined report operates on the complete vector
s = ( s 1 , s 2 , … , s 11 ) ,
together with the observable vectors and flags. It does not reduce the result immediately to one mechanism label.
The report can state:
  • candidate supported relative to declared alternatives, when a coherent subset of eligible rules agrees with the candidate and no declared alternative explains the same combination equally well;
  • layered, when more than one candidate remains compatible or different observables indicate concurrent behavior;
  • conflicting, when eligible rules give materially opposing indications;
  • insufficient, when the available rule states do not distinguish among candidates;
  • unavailable, when the measurements required for the requested distinction are absent; or
  • unexplained, when resolved behavior is not represented in the declared candidate set.
“Supported” is relational and conditional: it identifies compatibility with the observed rule vector relative to the alternatives actually considered, and is not a calibrated posterior probability, confidence score, or proof that the candidate mechanism is present.
The combined report also identifies corroborating measurements that would reduce ambiguity. An ambient-conditioned R9 result motivates collection of measured temperature trajectories for R8 and R10, which Section 6 reports for one measured replicate set, and a matched cooling-boundary comparison for R11 is identified as a next-stage measurement. The framework therefore connects abstention to experimental design.

5.8. Backend Technical Specification

Supplementary Materials S1 is the normative executable specification, including equations, preprocessing, windows, thresholds, sensitivity perturbations, confounder checks, code mappings, dependencies, and tests. This article does not reproduce pseudocode or an exhaustive backend schema.

5.9. Handoff to Applications

Section 6 applies this interface in three settings. The first is an ambient-temperature application evaluating R9 on external measured LiFePO4 discharge profiles; a measured cylindrical-cell application evaluating R8 on replicate records that carry synchronized electrical and surface-temperature channels; and controlled synthetic cases testing deterministic feature recovery, negative-control behavior, and abstention. Each is reported as configuration, G0 outcome, calculated observables, sensitivity behavior, state, and interpretation boundary, with full numerical definitions and test fixtures in Supplementary Materials S1 and S2.

6. Rule Applications and Deterministic Implementation Checks

6.1. Purpose and Evidence Separation

The three applications answer different questions. The published temperature-conditioned electrode profiles test whether the ambient-temperature screen captures a stable structure in an external battery dataset. The controlled synthetic records test whether the implementation reads inserted mathematical features as specified. The measured cylindrical-cell records with synchronized current, terminal voltage, and surface temperature test whether the declared R8 screen resolves a within-run surface-temperature shape across nominal replicates. Each measured-data application is bounded to the rule it exercises rather than to all eleven, and the synthetic cases are classified as deterministic implementation checks rather than physical validation; the measured applications and the next-stage validation program of Section 7.9 are reported separately.
Results are reported in the same order for each setting: data and configuration, G0 eligibility, calculated observables, sensitivity behavior, rule-local state, and interpretation boundary.

6.2. External Measured-Data Application of R9

6.2.1. Ombrini Data Source and Experimental Conditions

This application uses the open electrochemical dataset accompanying Ombrini et al. [25,26]. The selected file contains constant-current discharge profiles for a 1 mAh cm−2 LiFePO4 electrode at 268, 283, and 298 K and nominal rates of 0.5 C, 1 C, and 2 C, with 1 C defined as 1 mA cm−2. Each record contains declared temperature, rate, capacity, time, and terminal voltage.
As established in Section 3, the source provides no synchronized measured cell-temperature trajectory, chamber-tolerance record, or complete equilibration history. These are declared test-temperature-condition discharge curves, and they use the limited working approximation
T c e l l ≈ T a m b
only as the matching condition for R9 voltage geometry. It does not satisfy G0 for R8 or R10, which require measured T ( t ) , or for R11, which requires documented controlled cooling comparisons. Section 6.9 reports a separate measured record set that does satisfy G0 for R8.

6.2.2. Ombrini R9 Eligibility Assessment

G0 passes for the core R9 comparison because:
  • Voltage, physical capacity, rate, and declared temperature are present;
  • All nine records are discharge branches;
  • 0.5 C, 1 C, and 2 C are available at each temperature;
  • The fixed physical-capacity window is observed in every curve;
  • No extrapolation is required;
  • Rate-specific comparisons can be performed separately; and
  • The output is restricted to ambient-conditioned voltage geometry and accessible capacity.
G0 does not authorize within-run thermal interpretation. The temperature value is used as a matched experimental condition, not as a measured trajectory.

6.3. R9 Configuration

The principal comparison uses the physical-capacity window
q = 0.10 – 0.35   m A h   c m − 2 .
The same window is applied to all nine curves and is not selected independently from the derivative or curvature of each record. It was chosen during development after inspection of the available profiles because it is observed in every temperature–rate combination; its post-inspection selection is retained as a limitation.
Within each rate and temperature, the screen calculates the following:
  • Median voltage L m e d ;
  • Mean voltage L m e a n ;
  • Robust voltage slope s versus physical capacity;
  • Quadratic curvature magnitude κ V = | 2 a | , where V ( q ) = a q 2 + b q + c 0 ; and
  • Observed accessible capacity Q a c c .
For ordered temperatures T H > T L , define the level responses
Δ L m e d Δ T = L m e d ( T H ) − L m e d ( T L ) T H − T L ,
Δ L m e a n Δ T = L m e a n ( T H ) − L m e a n ( T L ) T H − T L .
Flattening is positive when the higher-temperature curve has the smaller absolute slope:
Δ F Δ T = | s ( T L ) | − | s ( T H ) | T H − T L .
The less-curvature response is
Δ κ V Δ T = κ V ( T L ) − κ V ( T H ) T H − T L .
Positive values indicate elevation, flattening, or lower curvature at the higher declared temperature. Each rate is evaluated separately because rate and temperature interact.
Sensitivity is assessed using all nine windows formed from lower bounds q l o ∈ { 0.05 , 0.10 , 0.15 } and upper bounds q h i ∈ { 0.30 , 0.35 , 0.40 } mAh cm−2. The measured curves are not treated as independent replicates. Conditional moving-block residual resampling examines numerical stability within each recorded curve, not population variability.

6.4. R9 Results

Figure 1 and Table 5 report the authors’ fixed-window analysis of the cited Ombrini source data [25,26]. At each rate, the 298 K curve lies above the 268 K curve through the analyzed interval; the separation increases with rate, and the higher-temperature curve has the smaller absolute slope at all three rates.
Figure 1. Ambient-temperature-conditioned voltage geometry in the Ombrini et al. LiFePO4 discharge data (source data [25,26]). Each panel carries a bold panel label at its upper left. Panels (a–c) show terminal voltage versus physical capacity at 268, 283, and 298 K for 0.5 C, 1 C, and 2 C, respectively. The shaded interval is the common primary window, q = 0.10 − 0.35 mAh cm−2. Panel (d) reports the 298 K minus 268 K median-voltage and flattening responses per kelvin, with value labels matching Table 5. Curvature is reported separately because the 2 C component is indeterminate. Temperature denotes the declared test-temperature condition; no measured cell T ( t ) is available. The arrow in panel (d) denotes the response calculated from 268 to 298 K.
Table 5. R9 fixed-window response from 268 to 298 K (authors’ analysis of source data [25,26]).
Median voltage, mean voltage, and flattening retain the positive direction in nine of nine sensitivity windows at every rate. The 2 C curvature component is positive in only one of nine windows and is therefore treated as indeterminate with respect to the proposed lower-curvature response; it is not combined with the stable level and slope components to manufacture a uniform result.
The magnitude of the temperature response increases with rate. The median-voltage response rises from +4.41 mV K−1 at 0.5 C to +14.21 mV K−1 at 2 C, and the flattening response rises from +15.07 to +28.77 mV (mAh cm−2)−1 K−1. The rate interaction is retained rather than pooling the three rates into one response.
Under the interface of Section 5, the core R9 level and flattening components are present for all three matched rates. The auxiliary curvature component is aligned at 0.5 C and 1 C; at 2 C its primary direction is opposing, and its local curvature state is indeterminate because it fails the directional-stability criterion. The combined R9 description is stable elevation and flattening with indeterminate 2 C curvature.

6.5. Interpretation of the Ambient-Temperature Application

The R9 result establishes a directionally stable ordering across the declared sensitivity windows in these records: higher declared temperature is associated with higher voltage, flatter plateau geometry, and greater accessible capacity, available from voltage, capacity, rate, and temperature labels alone.
The result does not identify why the curves differ. Temperature can affect charge-transfer kinetics, electrolyte transport, electronic and ionic resistance, active-capacity access, lithium-metal counter-electrode behavior, and the relation between the measured curve and the elected reference [4,25,29], and the dataset does not provide the measurements required to separate these contributions. The analysis also does not show that cell temperature remained exactly equal to the declared condition during discharge.
Because the fixed window was selected during development after the curves were inspected, the directional stability across nine nearby windows shows that the reported elevation and flattening are not confined to one exact interval but does not convert the dataset into an independent challenge. A stronger evaluation would freeze the R9 window and thresholds before applying them to a different uninspected cell or dataset.

6.6. Controlled Synthetic Implementation Checks

The synthetic cases evaluate whether selected implemented screens respond to declared mathematical features. Each case uses a fixed configuration and random seed, and the generator produces current, terminal voltage, normalized capacity, timing, and model-generated temperature channels with additive measurement noise. Controlled simulation and test-based diagnosis provide general context for this type of implementation check [30,31]. Generator equations, configurations, test fixtures, and diagnostic figures are provided in Supplementary Materials S1 and S2.
Three analytic feature forms are examined:
  • A positive end-of-pulse residual followed by exponential relaxation during rest;
  • A positive linear tilt across the pulse plateau; and
  • A negative sign-and-decay voltage feature under higher electrical stress.
A fourth case contains noise without an inserted feature. Only the screens implemented for these test fixtures are evaluated; rules requiring matched charge and discharge, multiple rates, measured temperature, multiple ambient conditions, or controlled cooling remain unavailable for these fixtures.
The model-generated temperature channel accompanying the synthetic records is not measured data, and its heat-balance formulation remains subject to the thermal reconciliation identified as T-01. That output is therefore not used to establish R8, R10, or R11 results; the measured records reported in Section 6.9, Section 6.10, Section 6.11 and Section 6.12 are an independent, non-model evidence path.

6.7. Synthetic Results

Case 1 shows that the relaxation estimator recovers the inserted positive decay and returns a fitted timescale near the generator value; the difference between 120 s and 131.6 s describes estimator behavior for this noise realization and is not a measured transport timescale. Case 2 shows that the plateau-geometry estimator recovers the inserted linear tilt, the fitted slope being an implementation diagnostic in normalized coordinates rather than a physical phase-property measurement.
Case 3 checks a voltage-only sign-and-decay detector contained in the software test package; it is not R8, R9, R10, or R11, and no thermal interpretation is assigned to its output. Case 4 shows that the implemented screens return feature absence within the declared resolution when the generator contains noise but no inserted analytic feature. One negative-control case does not establish a general false-positive rate or global refusal property. Table 6 summarizes the controlled synthetic feature-recovery and negative-control results; these are deterministic implementation checks and do not establish physical validation.
Table 6. Controlled synthetic feature-recovery and negative-control results.

6.8. What the Synthetic Cases Establish

The synthetic cases establish three implementation properties:
  • Identical configurations and seeds regenerate the reported records and outputs;
  • Each inserted analytic shape is recovered by the check designed to read it under the declared conditions; and
  • The noise-only record produces no resolved feature at the declared thresholds.
These results verify deterministic execution and generator-conditional feature recovery. The scope of these checks is implementation. Whether a physical mechanism produces the same feature in a measured cell, whether another mechanism could produce it, whether the thresholds generalize across instruments and protocols, and what the ensemble sensitivity, specificity, and error rates would be are questions for the measured applications and the next validation stage rather than for the synthetic records.

6.9. Measured A123 Thermal-Geometry Application of R8

6.9.1. Data Source and Experimental Condition

The second measured-data application uses third-party galvanostatic discharge records for A123 Systems ANR26650M1-B cylindrical LiFePO4/graphite cells reported by Catenaro and Onori [32]. Six nominal replicates, k1 through k6, were recorded at each of two chamber setpoints, 25 °C and 35 °C, giving twelve records. Each record carries synchronized current, terminal voltage, and can-surface temperature from a type-T thermocouple at the cell center, with a 2.0 V discharge cutoff. Across all twelve records, the mean discharge current is 2.5001–2.5004 A, the delivered capacity is 2.405–2.581 Ah, and the discharge duration is 3463–3717 s.
The measured surface departure is θ q = T s u r f q − T 0 , where T s u r f is the can-surface temperature and T 0 , written T0 throughout this article, the measured pre-discharge baseline of that record rather than the declared chamber setpoint. The per-record baselines span 24.443–25.418 °C at the 25 °C setpoint and 34.249–35.132 °C at the 35 °C setpoint. The depression metric is the difference between two values of θ q = T s u r f q − T 0 and is therefore baseline-invariant, whereas the integrals in Equations (7) and (9) are baseline-dependent, so the baseline convention is stated here and used throughout.
Surface temperature is not core temperature: no internal channel is present. The surface-to-core offset is not resolved here. For a cylindrical LiFePO4/graphite cell, Forgez et al. report core-minus-surface differences up to about 10 °C under high-current pulses, with a lumped-model estimation error below 1.5 °C [29]; the offset at the 1 C rate used here remains unquantified. An unquantified offset of this order is therefore a material confounder for any comparison against a depression depth of 0.15–0.24 °C, and it is carried as such in Section 6.12 rather than treated as negligible.

6.9.2. G0 Eligibility

Synchronized current, terminal voltage, and measured temperature trajectories are present, so R8 satisfies G0 on these records and is evaluated. R10 also satisfies G0 on the same channels and is reported as eligible but not interpreted causally, because correlation is not heat-flow direction, causation, or source separation. R11 remains unavailable: the set contains a single chamber convection condition per ambient setpoint and therefore no matched cooling-boundary contrast. The application is single-rate, which is a declared limitation of the record set rather than an omission.

6.10. A123 R8 Configuration and the First-Law Consistency Check

The screen is fixed before evaluation. Only the constant-current discharge segment, Step 5 of the source protocol, is used, and the surface-temperature series is smoothed with a 61-sample centered rolling mean, written T ~ . The early maximum of T ~ is located in the normalized-charge window q / Q ∈ 0.20 , 0.40 and the middle minimum in 0.40 , 0.65 . The depression metric is
Δ T d e p = T ~ q p e a k − T ~ q t r o u g h
Detection requires a depth exceeding the larger of 0.05 °C and three standard deviations of the per-replicate raw-minus-smoothed residual, which gives instrument-derived floors of 0.0615–0.0742 °C. These fixed screen settings, the two search windows, and the source record, Catenaro and Onori, Mendeley Data DOI 10.17632/kxsbr4x3j2.2 [32], are the provenance previously carried inside Figure 2 and are stated here and in the Figure 2 caption in readable text. The smoothing window, the segment selection, and the two search intervals were selected after inspection of the available records, so they carry the same post-inspection limitation as the R9 window; a window-perturbation screen over nine configurations is reported below.
Figure 2. Measured surface-temperature geometry of six A123 ANR26650M1-B replicates at 1 C and two ambient setpoints (source data [32]). Panels (a,b) carry bold panel labels at their upper left. Panel (a) shows the smoothed surface-temperature rise above the measured pre-discharge baseline of each record, T0, against the fraction of discharge completed at the 25 °C setpoint, and panel (b) shows the same quantity at the 35 °C setpoint, with the six-cell mean highlighted. The gray background band marks the fixed early-maximum window, q / Q in [0.20, 0.40], and the pale-yellow background band marks the fixed middle-minimum window, q / Q in [0.40, 0.65]. Screen provenance, reported here in readable text rather than inside the figure: the series are smoothed with a 61-sample centered rolling mean; detection requires a depth exceeding the larger of 0.05 °C and three standard deviations of the per-replicate raw-minus-smoothed residual; source data are the Catenaro and Onori Mendeley Data record, DOI 10.17632/kxsbr4x3j2.2 [32]. Surface temperature is measured on the cell can; core temperature is not measured.
The energy-domain consistency check applies Equation (7) in its time form. With τ = C t h / H obtained from an effective one-node fit to the post-discharge relaxation, Equation (6) integrates to
1 C t h ∫ t a t b Q ˙ g e n d t = θ t b − θ t a + 1 τ ∫ t a t b θ t d t
Both integrals in Equations (7) and (9) are taken on the same θ = T_surf − T0 defined in Section 4.7 and Section 6.9.1; no other baseline or reference temperature enters them. The left side is the integrated internal heat generation over the peak-to-trough interval, normalized by the effective heat capacity and therefore expressed in kelvin. The fit is a consistency check on signs and integrated magnitudes; it is not a validated thermal model, no thermal-model output is reported, and no microscopic heat source is identified.

6.11. A123 R8 Results

Figure 2 shows the smoothed surface-temperature trajectories against fraction of discharge completed at both ambient setpoints. Table 7 summarizes the depression geometry and the window-perturbation screen, and Table 8 the effective one-node relaxation fit and the integrated first-law balance. Per-replicate values are retained in the supplementary artifacts.
Table 7. Measured A123 1 C surface-temperature depression geometry and window-perturbation screen, by ambient setpoint. Unless a cell states otherwise, medians and ranges are taken over all six replicates at the setpoint, including any replicate recorded as absent within resolution; at 25 °C the median depth over the five resolved replicates only is 0.1785 °C against 0.153 °C over all six.
Table 8. Effective one-node relaxation fit and integrated first-law balance over the peak-to-trough interval, by ambient setpoint. Energies are normalized by the effective heat capacity and reported in kelvin. Each column reports the median of the six replicate values independently, so the column-wise medians need not satisfy the per-record identity generated = rejected + storage change termwise; the identity closes exactly for each individual replicate, and the per-replicate values are retained in the supplementary artifacts. All tabulated quantities are evaluated on θ = T_surf − T0 with T0 the measured pre-discharge baseline of each record, as defined in Section 4.7 and Section 6.9.1; the 25 °C and 35 °C labels remain the declared chamber setpoints.
At 35 °C, the depression is resolved in all six replicates, with median depth 0.237 °C over the range 0.224–0.287 °C, median early-maximum position q/Q = 0.304, and median middle-minimum position 0.548. At 25 °C, the depression is resolved in five of six replicates. Across all six 25 °C replicates, the median depth is 0.153 °C over the range 0.067–0.966 °C; across the five resolved replicates, the median depth is 0.1785 °C. The median early-maximum position at 25 °C is 0.318, and the median middle-minimum position is 0.505. Replicate k6 at 25 °C returns a depth of 0.0668 °C against its own floor of 0.0686 °C and is absent within resolution. That outcome is marginal: the depth lies 0.002 °C below the released floor, so the state depends on the residual-standard-deviation convention, which Supplementary Materials S2 fixes explicitly; the released state, absent within resolution, is the one reported here. Replicate k3 at 25 °C is an outlier at 0.966 °C, about six times the all-six 25 °C median. The 25 °C aggregate is therefore not reported as uniformly reproducible.
Under nine configurations of the smoothing window and the two search intervals, all six replicates pass at 35 °C in every configuration. At 25 °C, five replicates pass in all nine configurations and k6 passes in one of nine. The detection geometry is stable at 35 °C and mixed across replicates at 25 °C. The R8 local state is therefore present at 35 °C and mixed at 25 °C, with one replicate absent within resolution.
The effective one-node relaxation fit gives a median τ of 662 s at 25 °C over the range 510–912 s and 682 s at 35 °C over 482–819 s, with median coefficients of determination of 0.9992 and 0.9982. Evaluated over the peak-to-trough interval, all twelve records give positive integrated internal heat generation under the fitted identity. The median normalized storage change is −0.153 K at 25 °C and −0.237 K at 35 °C; the median rejected energy per unit effective heat capacity is 1.017 K and 1.300 K. The median generated energy per unit effective heat capacity is 0.848 K and 1.039 K. The surface temperature therefore fell because rejection exceeded a still-positive generation term; the records do not demonstrate negative net heat generation.

6.12. Interpretation of the A123 Application

The resolved feature is a surface-temperature depression: a within-run geometric feature of a measured trajectory. The integrated balance over the peak-to-trough interval identifies a heat-rejection-dominant interval. Across the central state-of-charge regions represented by the two pouch and full-cell coefficient datasets used for the sensitivity screen, reported entropic coefficients for LiFePO4/graphite cells near 298 K span approximately −0.42 to +0.17 mV K−1 [33,34]. Forgez et al. report an additional cell-specific sign-changing cylindrical-cell profile [29]. The interval retained here is therefore a selected literature sensitivity bound drawn from those datasets and not a universal LiFePO4/graphite envelope. It corresponds to a signed voltage-equivalent reversible term of roughly −125 to +51 mV and a reversible heat contribution of about +0.125 to −0.051 W A−1 under the discharge-positive convention of Equation (6). Magnitudes can be larger near the end regions of charge and discharge.
That interval is an externally supplied sensitivity bound. It is not a fitted cell-specific coefficient for these cells, nor an estimate of the r t h e r m a l term in Equation (5), and it does not make Equation (5) identifiable. The observed depression is compatible with a reversible contribution of literature-supported sign and magnitude and is not uniquely attributed to it. No entropy value, entropic coefficient, or state-of-charge-resolved entropy profile is measured, fitted, or isolated here. Alternative contributors remain admissible, including a rate- and temperature-dependent irreversible term and the unresolved surface-to-core offset of Section 6.9.1.
The R8 result is a measured, non-model evidence path. Equations (6)–(9) are used as identity constraints on signs and integrated balances, with no fitted thermal-model parameters reported, so the reconciliation T-01 continues to apply to the model-generated temperature channel of the synthetic records and to any provisional parameterized thermal artifact. No deployment, diagnostic-performance, or battery-management claim follows from this application.

6.13. Combined Application Result

The three applications are complementary rather than interchangeable. R9 extracts stable declared-condition voltage elevation and flattening from external measured electrode profiles while retaining indeterminate 2 C curvature; R8 resolves a within-run surface-temperature depression whose integrated first-law balance is heat-rejection-dominant and not uniquely attributed to a reversible contribution; and the synthetic cases show that selected software checks recover inserted shapes and return the declared noise-only control outcome. Together they establish bounded observable results inside the partial-observability boundary, which they do not remove; external physical evidence for the synthetic records is part of the next validation stage. Section 7 interprets their combined methodological significance, limitations, and validation implications.

7. Discussion

7.1. Meaning of the Combined Evidence

The four evidence forms close different links in one reasoning chain. The Zeng–Bazant comparison qualifies a physics-based reference within a declared model regime; the Ombrini application shows that an observable screen can report directionally stable declared-condition voltage geometry in external measured electrode records; the A123 application shows that a declared thermal screen resolves a measured within-run surface-temperature depression and constrains its integrated balance without unique heat-source attribution; and the synthetic cases check selected deterministic implementation paths. The human–AI development record is a descriptive methodological account and is not a fifth validation form.
The combined contribution is methodological. A qualified reference is connected to a composite observable, the observable is evaluated through rules with eligibility and abstention, and the implementation is tested against controlled inputs. The framework organizes what can be answered, what remains ambiguous, and what cannot be evaluated from the available record; it does not solve the inverse problem from terminal signals to internal state.

7.2. Physics as a Constraint on Sparse-Signal Inference

The plateau relation constrains inference without becoming a direct measurement. A reference can structure a comparison while the residual remains composite and reference-dependent, so sign, rate dependence, relaxation, branch asymmetry, and declared-condition geometry can be evaluated without assigning any one contributor a unique cause. This is why corroboration and conflict must remain visible: a layered rule vector is more faithful than a forced mechanism label when unresolved electrode, electrolyte, transport, contact, thermal, sensor, and reference contributions can coexist.

7.3. Significance of the Ambient-Temperature Application

The R9 application illustrates a multicomponent result: its level and flattening components are directionally stable across the declared sensitivity windows, while the 2 C curvature component is retained as indeterminate rather than discarded. Rate must therefore remain a conditioning variable, and a mixed component must neither reject stable components nor be suppressed to create a uniform narrative.
The application concerns voltage geometry across declared test-temperature conditions. It is not a synchronized cell-temperature trajectory, a claim of exact isothermality, or evidence of heat generation, thermal feedback, cooling adequacy, or a unique temperature mechanism. Transfer to another loading, electrode architecture, counter electrode, cell format, aging state, or manufacturer requires a new eligibility assessment and a frozen external challenge.

7.4. Significance of the Measured Thermal-Geometry Application

The A123 application adds a measured within-run temperature-geometry result to a framework whose other measured application concerns voltage geometry alone. Its methodological content is that a screen declared before evaluation resolves a surface-temperature depression in all six replicates at 35 °C and in five of six at 25 °C. A second methodological point is that an integrated first-law identity converts that geometry into a signed statement about an interval rather than into a mechanism.
The distinction that carries the interpretation is between a measured heat-rejection-dominant interval and a unique entropic attribution. Over the peak-to-trough interval, the integrated balance shows that rejection exceeded a still-positive internal generation term in every record; it does not show negative net heat generation, and it does not isolate a reversible contribution. The depression is compatible with a reversible contribution of literature-supported sign and magnitude and is not uniquely attributed to it. Surface temperature is not core temperature, the record set is single-rate, and no matched cooling boundary is available, so R10 is reported as eligible without causal interpretation, and R11 remains unavailable. T-01 remains open only for the excluded synthetic and provisional parameterized thermal artifacts and for the unresolved full mechanistic decomposition, neither of which this application supplies.

7.5. What the Synthetic Cases Contribute

Synthetic checks support deterministic execution under their declared generator conditions, showing whether feature extraction, sign handling, fitting, and state assignment behave as specified, including a noise-only control. Their fitted quantities are implementation diagnostics, not measured material parameters, physical mechanisms, calibrated diagnostic thresholds, or general false-positive rates. Implementation verification and physical validation therefore remain separate requirements.

7.6. Implications for a Sparsely Instrumented BMS

For a sparsely instrumented BMS, rule availability is local: electrical geometry may be evaluable while temperature-trajectory geometry is unavailable [1,30,35]. Rate scans, interruptions, declared ambient changes, and controlled cooling comparisons provide contrasts that a single discharge cannot, and the interface identifies which additional measurement would reduce an ambiguity.
Reference choice must remain part of the diagnostic record, because empirical low-current and particle-model current-conditioned references are not equivalent. Indeterminate, unavailable, and unexplained states can appropriately trigger data collection, model review, or conservative operation. The study does not demonstrate onboard implementation, control policy, sensor qualification, fault tolerance, timing, memory, computational load, or safety-logic integration.

7.7. Implications for Human-Guided AI in Battery Science

Generative AI is placed upstream of a deterministic scientific object. It can compare formulations, generate alternatives, test wording against observability, assist calculations, and expose inconsistencies, while the human author selects the model, reference, threshold status, evidence boundary, and final claim. Physics constraints, explicit alternatives, G0, and abstention guard against fluent causal narratives that sparse measurements cannot distinguish [14,15,16,17,18,19,20], with recent battery-focused LLM work providing adjacent application context [2,3].
The deterministic handoff permits a runtime result to be traced to inputs, a named reference, fixed configuration, observables, and decision logic. This is one documented development architecture, not evidence of gains in speed, accuracy, creativity, or reliability relative to human-only or AI-only development.

7.8. Limitations

R9 and R8 each received one external measured-data application; the remaining rules require protocols or channels outside the available records, so error rates, detection limits, and abstention rates are reported as uncalibrated. The R9 window and the R8 depression windows were developed after inspection, and frozen independent challenges are the next validation stage for both. The plateau reference is qualified within its particle-model assumptions and possible full-cell contributors, and alternative admissible references are to be tested in that stage.
Thermal observability remains partial: the Ombrini records carry no measured temperature trajectory, the synthetic temperature channel is model-generated, and the measured cylindrical-cell records provide surface rather than core temperature at a single rate. T-01 requires reconciliation of the heat balance, reversible-heat convention, parameters, boundary conditions, and implementation before thermal-model outputs are used scientifically, and it also covers the unresolved full mechanistic decomposition. R10 is eligible on the A123 records but is not reported causally, and R11 remains outside the implemented applications because no matched cooling-boundary contrast is available. Synthetic tests use deliberately constructed features and limited configurations, and independent replication of the full human–AI development path is a next-stage item.

7.9. Next Validation Program

The next program is to (1) freeze R9 logic before an uninspected temperature-series challenge; (2) test transfer across loading, formats, counter-electrode configurations, manufacturers, and aging states; (3) extend synchronized current, voltage, and measured-temperature collection for R8 and R10 across additional rates, cell formats, and instrumented core-temperature channels, freezing the depression windows before an uninspected replicate set; (4) perform matched documented cooling tests for R11; (5) obtain interruption, memory, charge–discharge, and rate-scan protocols; (6) compare admissible references; (7) build labeled mixed, nuisance, near-threshold, and out-of-class ensembles; (8) reconcile T-01 and regenerate affected artifacts; and (9) independently replicate the deterministic analyses and separately study the development method.

7.10. Discussion Summary

The evidence supports a coherent, explicitly bounded architecture: physics supplies a qualified reference, sparse records support bounded observable statements, and deterministic implementation retains declared outputs and abstention. The value delivered is an auditable account of what the record supports, what remains compatible with alternatives, and what requires further measurement, rather than a definitive mechanism label.

8. Conclusions

Battery diagnosis begins with an asymmetry: electrochemical theory describes distributed internal states, while routine records contain limited electrical and thermal signals and cannot generally reconstruct unique concentration fields, phase boundaries, heat sources, or electrode-specific losses. The appropriate task is physics-bounded candidate screening, not unrestricted mechanism identification.
A qualified LiFePO4 plateau reference and a two-coordinate representation organize terminal voltage relative to an elected reference, and the resulting voltage residual remains composite and reference-dependent rather than thermodynamic work or a unique loss decomposition. G0, R1–R11, four local states, and combined outcomes preserve resolved features, absence within resolution, conflict, indeterminacy, and unavailable evidence.
The separated evidence supports correspondingly bounded conclusions. Published Zeng–Bazant model curves qualify the reference within its stated model regime. The Ombrini measured electrode profiles support an R9 application reporting stable declared-condition elevation and flattening with indeterminate 2 C curvature. The measured cylindrical-cell replicates support an R8 application reporting a within-run surface-temperature depression and a heat-rejection-dominant integrated interval that is compatible with a reversible contribution of literature-supported sign and magnitude and is not uniquely attributed to it. Controlled synthetic cases support deterministic, generator-conditional feature recovery and a negative-control outcome, not physical validation or calibrated diagnostic performance.
Generative AI supported development under human authority; the released evaluator is deterministic and non-generative. This is a documented scientific-development architecture, not evidence that AI assistance is superior to another development method or that the system is ready for onboard deployment.
The contribution established here is a physics-bounded, abstention-aware method for organizing sparse battery evidence and directing the next measurement; the program of Section 7.9 defines the next validation stage for broader physical validation.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/batteries12090335/s1, Supplementary Materials S1: backend technical rule specification; Supplementary Materials S2: reproducibility and evidence package; Supplementary Materials S3: human–AI development record. Appendix A indexes each principal result and methodological claim against its supporting artifact. Thermal-model artifacts subject to reconciliation T-01 are excluded from the scientific supporting evidence; the measured A123 thermal-geometry package in Supplementary Materials S2, a123_r8/, is included as measured supporting evidence and is not a thermal-model artifact. The complete Supplementary Materials S1–S3 package is archived under the published Zenodo DOI 10.5281/zenodo.22082766 recorded in the Data Availability Statement.

Author Contributions

Conceptualization, R.P. (Roger Painter) and I.E.; methodology, R.P. (Roger Painter) and R.P. (Ranganathan Parthasarathy); software, R.P. (Roger Painter) and I.E.; formal analysis, R.P. (Roger Painter); investigation, R.P. (Roger Painter); resources, L.L., L.S. and S.K.H.; data curation, R.P. (Roger Painter); writing—original draft preparation, R.P. (Roger Painter) and I.E.; writing—review and editing, R.P. (Roger Painter), R.P. (Ranganathan Parthasarathy) and I.E.; visualization, R.P. (Roger Painter); supervision, L.L., L.S. and S.K.H.; project administration, L.L., L.S. and S.K.H.; funding acquisition, L.L., L.S. and S.K.H. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Massie Chair of Excellence at Tennessee State University and the Office of the Dean of the College of Engineering at Tennessee State University. This research was supported by the U.S. National Science Foundation UJIMA program under Award No. 2430323.

Institutional Review Board Statement

Not applicable. This study did not involve human participants or animals.

Data Availability Statement

The Zeng–Bazant model curves used for the plateau-reference comparison are available in the cited publication [21]. The measured temperature-conditioned LiFePO4 discharge profiles used for the R9 application are available from Ombrini et al. [25,26], Zenodo record 17304994, DOI: 10.5281/zenodo.17304994, under CC BY 4.0. The measured A123 Systems ANR26650M1-B records used for the R8 application are third-party data from Catenaro and Onori [32], available from the public Mendeley Data record, DOI: 10.17632/kxsbr4x3j2.2. The raw third-party spreadsheet files are not redistributed in the Supplementary Materials, and the source record is cited and linked instead. No original physical-cell experiments were performed by the authors for this study; all measured records are third-party. The authors’ rule specification, deterministic software, analysis configurations, derived results, sensitivity outputs, synthetic cases, and reproducibility tests are provided in the Supplementary Materials indexed in Appendix A, including the A123 reproduction path in Supplementary Materials S2, a123_r8/. Synthetic records support implementation checking only, and thermal-model artifacts subject to T-01 are excluded from the scientific evidence. The complete Supplementary Materials S1–S3 package is publicly archived on Zenodo under DOI 10.5281/zenodo.22082766.

Acknowledgments

Generative artificial-intelligence tools were used under human author direction for literature organization, candidate-rule formulation, alternative-explanation and counterexample generation, code drafting and inspection, calculation support, consistency checking, documentation, and manuscript drafting. Human authors selected the scientific questions, physical models, assumptions, references, thresholds, analyses, and final claims; verified cited sources and reported calculations; reviewed and edited all generated material; and accepted responsibility for the published work. Generative AI is not an author and is not used by the deterministic runtime rule evaluator. The authenticated development record does not preserve a complete platform, model-family, or version, and access-date inventory; no missing identities or timestamps were reconstructed retrospectively. This disclosure therefore records verified tool functions, human scientific authority, and the deterministic runtime boundary.

Conflicts of Interest

I.E. is the owner of EcoC2S. The paper reflects the views of the authors and not the company. The remaining authors declare no conflicts of interest.

Appendix A. Guide to the Supplementary Materials and Reproducibility Artifacts

Appendix A.1. Purpose

Appendix A is an index and user guide to the Supplementary Materials. It maps the principal equations, rules, tables, figures, and methodological claims in the article to the corresponding supplementary artifact and identifies the appropriate starting point for reproduction or audit.

Appendix A.2. Artifact Map

The artifact map is provided in Table A1.
Table A1. Guide to the Supplementary Materials and principal supported content.

Appendix A.3. Suggested Reading Paths

Readers interested primarily in the scientific argument can read the main article without opening every supporting artifact. Readers seeking implementation detail should begin with Supplementary Materials S1; readers reproducing a reported result should use the corresponding Supplementary Materials S2 subdirectory and its local readme; readers examining the role of generative AI should begin with Supplementary Materials S3.
Each Supplementary Materials S2 subdirectory contains a short local readme specifying:
  • The manuscript result reproduced;
  • Required input files;
  • Execution command;
  • Expected output files;
  • Numerical acceptance checks;
  • Software environment; and
  • Known limitations.

Appendix A.4. Status and Interpretation Guide

Each artifact in the supplementary set is identified as one of the following:
  • Implemented and reported, supporting a result in the article;
  • Implemented but not evaluated on the required data, supporting a specification or software capability only;
  • Prospective, describing planned work without a reported result; or
  • Excluded pending reconciliation, indicating that the artifact is not used as scientific evidence.
The status guide lets a reader confirm which artifacts support a reported result and which describe a specification, planned work, or material excluded pending reconciliation. The existence of code, a figure, or a configuration is read as distinct from completion of the corresponding physical evaluation.

References

  1. Son, J.; Du, Y. Model-Based Stochastic Fault Detection and Diagnosis of Lithium-Ion Batteries. Processes 2019, 7, 38. [Google Scholar] [CrossRef] [Scilit]
  2. Chen, J.; Gui, X.; Fang, S.; Tao, S.; Zheng, S.; Liu, W.; Bian, J. Battery-Sim-Agent: Leveraging LLM-Agent for Inverse Battery Parameter Estimation. arXiv 2026, arXiv:2605.29560. [Google Scholar] [CrossRef] [Scilit]
  3. Khan, A.; Nahar, R.; Chen, H.; Constante Flores, G.E.; Li, C. FaultExplainer: Leveraging Large Language Models for Interpretable Fault Detection and Diagnosis. Comput. Chem. Eng. 2025, 199, 109152. [Google Scholar] [CrossRef] [Scilit]
  4. Safari, M.; Delacourt, C. Modeling of a Commercial Graphite/LiFePO4 Cell. J. Electrochem. Soc. 2011, 158, A562–A571. [Google Scholar] [CrossRef] [Scilit]
  5. Doyle, M.; Fuller, T.F.; Newman, J. Modeling of Galvanostatic Charge and Discharge of the Lithium/Polymer/Insertion Cell. J. Electrochem. Soc. 1993, 140, 1526–1533. [Google Scholar] [CrossRef] [Scilit]
  6. Santhanagopalan, S.; Guo, Q.; Ramadass, P.; White, R.E. Review of Models for Predicting the Cycling Performance of Lithium Ion Batteries. J. Power Sources 2006, 156, 620–628. [Google Scholar] [CrossRef] [Scilit]
  7. Marquis, S.G.; Sulzer, V.; Timms, R.; Please, C.P.; Chapman, S.J. An Asymptotic Derivation of a Single Particle Model with Electrolyte. J. Electrochem. Soc. 2019, 166, A3693–A3706. [Google Scholar] [CrossRef] [Scilit]
  8. Bai, P.; Cogswell, D.A.; Bazant, M.Z. Suppression of Phase Separation in LiFePO4 Nanoparticles During Battery Discharge. Nano Lett. 2011, 11, 4890–4896. [Google Scholar] [CrossRef] [Scilit]
  9. Venkatasubramanian, V.; Rengaswamy, R.; Kavuri, S.N. A Review of Process Fault Detection and Diagnosis Part II: Qualitative Models and Search Strategies. Comput. Chem. Eng. 2003, 27, 313–326. [Google Scholar] [CrossRef] [Scilit]
  10. Kuipers, B. Qualitative Simulation. Artif. Intell. 1986, 29, 289–338. [Google Scholar] [CrossRef] [Scilit]
  11. de Kleer, J.; Williams, B.C. Diagnosing Multiple Faults. Artif. Intell. 1987, 32, 97–130. [Google Scholar] [CrossRef] [Scilit]
  12. Milne, R.; Travé-Massuyès, L. Real-Time Model Based Diagnosis of Gas Turbines. In Artificial Intelligence in Engineering (AIENG’93); WIT Press: Southampton, UK, 1993; Available online: https://www.witpress.com/Secure/elibrary/papers/AIENG93/AIENG93019FU.pdf (accessed on 31 July 2026).
  13. Kościelny, J.M.; Syfert, M.; Wnuk, P. Diagnostic Row Reasoning Method Based on Multiple-Valued Evaluation of Residuals and Elementary Symptoms Sequence. Energies 2021, 14, 2476. [Google Scholar] [CrossRef] [Scilit]
  14. Garrido-Merchán, E.C.; Puente, C. GOFAI Meets Generative AI: Development of Expert Systems by Means of Large Language Models. arXiv 2025, arXiv:2507.13550. [Google Scholar] [CrossRef] [Scilit]
  15. Nguyen, Q.T.; Pham, T.-B.; Bui, H.P.; Chen, P.-H. Applying Action Research to Developing a GPT-Based Assistant for Construction Cost Code Verification in State-Funded Projects in Vietnam. Buildings 2026, 16, 499. [Google Scholar] [CrossRef] [Scilit]
  16. Ozpinar, A.; Baygul Ozpinar, S. SAPIENT: A Multi-Agent Framework for Corporate Reputation Intelligence Through Sentinel Monitoring and LLM-Based Synthetic Population Simulation. Systems 2026, 14, 425. [Google Scholar] [CrossRef] [Scilit]
  17. Caridi, A.; Giovannini, M.; Ricciardi Celsi, L. AI-Assisted Value Investing: A Human-in-the-Loop Framework for Prompt-Guided Financial Analysis and Decision Support. Electronics 2026, 15, 1155. [Google Scholar] [CrossRef] [Scilit]
  18. Kwack, H.; Kong, H.; Lim, J.; Zhang, B.-T.; Hahn, J.; Chang, M.J. PKGPT: Expert-Orchestrated Recursive LLM Agent for Automated NONMEM PopPK Modeling with Human Benchmarking. Pharmaceutics 2026, 18, 501. [Google Scholar] [CrossRef] [Scilit]
  19. Kim, J.; Shin, H. Stage-Aware Governance of Large Language Models: Managing Uncertainty and Human Oversight in AI-Assisted Literature Review Systems. Systems 2026, 14, 153. [Google Scholar] [CrossRef] [Scilit]
  20. González-Potes, A.; Martínez-Castro, D.; Paredes, C.M.; Ochoa-Brust, A.; Mena, L.J.; Martínez-Peláez, R.; Félix, V.G.; Félix-Cuadras, R.A. Hybrid AI and LLM-Enabled Agent-Based Real-Time Decision Support Architecture for Industrial Batch Processes: A Clean-in-Place Case Study. AI 2026, 7, 51. [Google Scholar] [CrossRef] [Scilit]
  21. Zeng, Y.; Bazant, M.Z. Phase Separation Dynamics in Isotropic Ion-Intercalation Particles. SIAM J. Appl. Math. 2014, 74, 980–1004. [Google Scholar] [CrossRef] [Scilit]
  22. Cogswell, D.A.; Bazant, M.Z. Coherency Strain and the Kinetics of Phase Separation in LiFePO4 Nanoparticles. ACS Nano 2012, 6, 2215–2225. [Google Scholar] [CrossRef] [Scilit]
  23. Gemmer, J.; Michel, M.; Mahler, G. Quantum Thermodynamics: Emergence of Thermodynamic Behavior Within Composite Quantum Systems, 2nd ed.; Lecture Notes in Physics 784; Springer: Berlin/Heidelberg, Germany, 2009. [Google Scholar] [CrossRef] [Scilit]
  24. Shao, X. First Law Energy Balance as a Data Screening Tool. Master’s Thesis, Texas A&M University, College Station, TX, USA, 2005. Available online: https://oaktrust.library.tamu.edu/items/e5e43d28-a140-4482-837d-e692e24bc509 (accessed on 31 July 2026).
  25. Ombrini, P.; Pathak, S.; Ntagkras, D.; Pal, S.K.; Karanth, P.; Mulder, F.M.; Wagemaker, M.; Bazant, M.Z.; Vasileiadis, A. Modeling Single-Crystal Electrodes as a Network of Primary Particles. Energy Environ. Sci. 2025, 18, 9468–9477. [Google Scholar] [CrossRef] [Scilit]
  26. Ombrini, P. Dataset of “Modeling Single-Crystal Electrodes as a Network of Primary Particles”, Ombrini et al., 2025, EES [Data set]. Zenodo. 2025. Available online: https://zenodo.org/records/17304994 (accessed on 31 July 2026).
  27. Künsch, H.R. The Jackknife and the Bootstrap for General Stationary Observations. Ann. Stat. 1989, 17, 1217–1241. [Google Scholar] [CrossRef] [Scilit]
  28. Bazant, M.Z. Theory of Chemical Kinetics and Charge Transfer Based on Nonequilibrium Thermodynamics. Acc. Chem. Res. 2013, 46, 1144–1160. [Google Scholar] [CrossRef] [Scilit]
  29. Forgez, C.; Vinh Do, D.; Friedrich, G.; Morcrette, M.; Delacourt, C. Thermal Modeling of a Cylindrical LiFePO4/Graphite Lithium-Ion Battery. J. Power Sources 2010, 195, 2961–2968. [Google Scholar] [CrossRef] [Scilit]
  30. Sun, B.; Zhao, X.; He, X.; Ruan, H.; Zhu, Z.; Zhou, X. Virtual Battery Pack-Based Battery Management System Testing Framework. Energies 2023, 16, 680. [Google Scholar] [CrossRef] [Scilit]
  31. Kaufmann, D.; Kozovsky, M.; Wotawa, F. Simulation-Based Diagnosis for Cyber-Physical Systems—A General Approach and Case Study on a Dual Three-Phase E-Machine. In Proceedings of the 35th International Conference on Principles of Diagnosis and Resilient Systems (DX 2024); Open Access Series in Informatics (OASIcs); Schloss Dagstuhl—Leibniz-Zentrum für Informatik: Dagstuhl, Germany, 2024; Volume 125, pp. 18:1–18:21. [Google Scholar] [CrossRef]
  32. Catenaro, E.; Onori, S. Experimental data of lithium-ion batteries under galvanostatic discharge tests at different rates and temperatures of operation. Data Brief 2021, 35, 106894. [Google Scholar] [CrossRef] [Scilit]
  33. Bazinski, S.J.; Wang, X. The Influence of Cell Temperature on the Entropic Coefficient of a Lithium Iron Phosphate (LFP) Pouch Cell. J. Electrochem. Soc. 2014, 161, A168–A175. [Google Scholar] [CrossRef] [Scilit]
  34. Neupane, S.; Alipanah, M.; Barnes, D.; Li, X. Heat Generation Characteristics of LiFePO4 Pouch Cells with Passive Thermal Management. Energies 2018, 11, 1243. [Google Scholar] [CrossRef] [Scilit]
  35. Painter, R.; Parthasarathy, R.; Li, L.; Embry, I.; Sharpe, L.; Hargrove, S.K. A Digital Twin Approach for Battery Management Systems for LiFePO4 Batteries. In Proceedings of the COMSOL Conference 2024 Boston, Boston, MA, USA, 7–8 October 2024; Available online: https://www.comsol.com/paper/a-digital-twin-approach-for-battery-management-systems-for-lifepo4-batteries-136512 (accessed on 31 July 2026).
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.