Skip to Content
FluidsFluids
  • Article
  • Open Access

15 March 2026

18 Pages

Design and Characterization of a Bench-Top Ludwieg Tube for Aerodynamic Measurements via Simultaneous Quantification of Mach Number and Velocity

,
,
,
,
,
and
Aerospace Engineering, Texas A&M University, 1733 George Bush Dr. West, College Station, TX 77845, USA
*
Author to whom correspondence should be addressed.
This article belongs to the Special Issue High-Speed Processes in Continuous Media

Abstract

This article presents the design and detailed characterization of a new supersonic wind tunnel at the Aerospace Laboratory for Lasers, ElectroMagnetics, and Optics of Texas A&M University, tailored for optical diagnostic development and sub-scale fundamental compressible fluid dynamics research. A Ludwieg tube tunnel architecture was selected due to its robustness, versatility, and low operational costs. The tunnel consists of a 50-foot-long driver tube constructed from modular Tri-Clamp spools, a Mach 4 nozzle with 3 in. exit diameter configured as a free jet, and a fast-acting valve with 14 ms opening time for high-duty-cycle operation. Such construction proved to be a robust, compact, and affordable solution for academic applications. Characterization methods consisted of simultaneous high-speed dot-schlieren, total and static pressure measurements, and femtosecond laser electronic excitation tagging. Average flow velocity for the first steady-state test time was measured via FLEET at (668.0 ± 5.7) m/s. The Mach number was calculated based on the angles of the attached oblique shocks formed near the 30° cone model. Calculated Mach number was repeatable from run to run and had small oscillations near the average value of 3.96 ± 0.03. Based on the simultaneously measured velocity and Mach number, the static temperature was calculated to be between (68.6 ± 0.3) K and (66.3 ± 0.3) K throughout the 400 ms test time, completely defining the thermodynamic state of the generated freestream flow.

1. Introduction

The design of supersonic vehicles is a complex, multidisciplinary optimization problem requiring careful balancing of numerous interrelated factors [1]. While computational fluid dynamics (CFD) has become integral to this process, reliance on numerical methods presents significant challenges, as code accuracy must be rigorously validated against experimental data [2]. Flight testing provides the ultimate validation data; however, the prohibitive costs make it impractical for early-stage design or fundamental research. Consequently, wind tunnel testing remains the primary method for both fundamental research and for acquiring the representative data necessary to validate computational models [3].
Some of the challenges associated with generating high-quality data via wind tunnel testing are precise facility characterization and target flow phenomenon quantification [4]. Some recent studies specifically call for new experimental data produced by well-characterized facilities employing advanced optical diagnostics for non-intrusive measurements [5]. Non-intrusive optical measurements are often better at capturing transient flow phenomena, especially in pulsed facilities, in comparison to conventional physical probes [6]. However, many large-scale facilities can use only well-tested diagnostics known to provide reliable results due to prohibitively high operational costs. Therefore, smaller facilities capable of reproducing relevant flow conditions are needed to develop and test innovative measurement methods before full-scale deployment.
In this article, the Bench-top Ludwieg Tube for Aerodynamic Measurements (BLAM) is designed, constructed, and characterized to address the aforementioned need for affordable, sub-scale, high-speed facilities at Texas A&M University. It is located at the Aerospace Laboratory for Lasers, ElectroMagnetics, and Optics (ALLEMO), which develops new diagnostic and aero-optical capabilities for aerospace engineering applications. BLAM is a 50-foot-long Ludwieg tube with a 3 in. exit diameter axisymmetric Mach 4 nozzle equipped with a fast-acting valve for high-duty-cycle operation of the tunnel. The Ludwieg tube architecture was chosen for its reliability, low operational costs, and controllable test gas composition [7]. Additionally, Ludwieg tubes are capable of generating relevant flow environments with representative Mach and Reynolds numbers. For these reasons, Ludwieg-type wind tunnels occupy a permanent spot in academia for both sub-scale and large-scale supersonic and hypersonic testing [7,8,9,10,11]. The axisymmetric nozzle design was chosen based on manufacturing simplicity and avoidance of side-wall vortices that are formed in rectangular nozzles [12,13]. The fast-acting valve eliminates the need for diaphragm replacement and reduces the tunnel reset time to minutes, which is only limited by the vacuum system.
The tunnel operation and the generated freestream flow conditions were characterized via simultaneous high-speed pressure measurements, velocity measurement via femtosecond laser electronic excitation tagging (FLEET), and Mach number measurement via high-speed dot-schlieren. FLEET is a molecular tagging velocimetry method, which has proven to be a powerful tool for quantification of transport parameters in high-speed flows, including velocity, vorticity, and acceleration [14]. For more information about molecular tagging velocimetry in general, and FLEET in particular, please consult a recent review by Carter et al. [15]. Schlieren is another robust optical diagnostic that has been extensively used for both qualitative flow visualization and quantitative analysis, such as Mach number measurements based on attached shock angles or shock stand-off distances [16,17]. In this work, a dot-schlieren variant was employed for its sensitivity to density gradients in all directions, providing symmetric flow visualization [18]. Together, velocity and Mach number measurements were used to calculate the static temperature evolution in the core flow. Combined with the static and stagnation pressure measurements and set flow composition, velocity, Mach number, and static temperature fully define the thermodynamic state of the flow. Lastly, spatial and temporal velocity distributions across the flowfield were measured and are presented in this article.

2. Experimental Setup

Tunnel Architecture and Instrumentation

Similar to the vast majority of modern Ludwieg tubes, BLAM consists of a driver tube, fast-acting valve, test section, and vacuum tank, as shown in Figure 1. This section describes the overall architecture of the facility and a few decisions made during the design stage.
Figure 1. CAD rendering of the tunnel with the main components identified.
The few limiting factors for the design of the facility were: physical space available at the laboratory, a small construction budget, low operational cost, and rapid firing capability. The starting point for the design decision chain was the selection of an off-the-shelf vacuum tank that would reasonably fit into the laboratory space without modifying the existing infrastructure. A 400 gallon (1.5 m3) tank, rated to 165 psi working pressure, from Compressor World was chosen to serve as the vacuum tank for the facility. Given the existing portable vacuum systems at ALLEMO, it was estimated that the vacuum tank could be evacuated to 1 torr in approximately 10–15 min. Based on the fill time of the tank, liquefaction of the unheated air expanding through the nozzle, and matching of static temperature and Reynolds number of the facilities at the National Aerothermochemistry and Hypersonics Laboratory (NAHL), a design Mach number of 4 was chosen. Information on air liquefaction conditions can be found in the work by Pope and Goin [19]. The liquefaction curve for air reproduced from Pope and Goin, transformed into the SI unit system, can be found in the work by Gragston et al. [10].
The nozzle size was determined based on the fill rate of the vacuum tank, which needed to be longer than the desired 100 ms run time, and the isentropic expansion ratio for Mach 4. The mass flow rate for a choked nozzle is calculated as shown in Equation (1):
m ˙ = P t A ★ γ R T t γ + 1 2 γ + 1 2 ( 1 − γ ) ,
where m ˙ is the mass flow rate [kg/s], P t is the total pressure in the driver tube [Pa], A ★  is the critical area of the nozzle [ m 2 ], γ is the ratio of specific heats [dimensionless], R is the specific gas constant [ J   kg − 1   K − 1 ], and T t is the total temperature in the driver tube [K]. It is worth noting that the ratio of specific heats, γ , for nitrogen, the primary test gas for this work, equals 1.40 across the entire range of temperatures and pressures encountered during testing, according to the tabulated data from Hilsenrath et al. [20]. Based on the maximized nozzle size, allowing for at least 100 ms of run time, a 3 in. (75.9 mm) nozzle exit diameter was chosen, corresponding to a critical nozzle diameter, D ★ , of 22.26 mm. For more information on the nozzle design, please see Section 3.
The next element in the design chain was the sizing of the driver tube. Once the fast-acting valve is actuated, the flow inside the driver tube can be described as an expansion wave traveling upstream along the driver tube at the local speed of sound. As the gas is expanded by the passing wave, its flow parameters are described by the following J + Riemann invariant:
2 a 0 γ − 1 + u o = 2 a 1 γ − 1 + u 1 ,
where a is the local speed of sound [m/s] and u is the flow velocity [m/s] [10,21]. Subscript “0” corresponds to the properties ahead of the expansion wave, and “1” corresponds to the properties behind the wave. To simplify the following derivations, Equation (2) is rearranged as a function of Mach number:
a 1 a 0 = 1 + γ − 1 2 M 0 1 + γ − 1 2 M 1 .
Assuming an ideal gas and u 0 = 0 , Equation (2) leads to the following relations for the static temperature and density after the first expansion wave passage in the driver tube:
T 1 T t , 0 = 1 + γ − 1 2 M 1 − 2 ,
ρ 1 ρ t , 0 = 1 + γ − 1 2 M 1 − 2 γ − 1 ,
where T 1 is the static temperature of gas after expansion [K] and ρ is the density [ kg / m 3 ]. When combined with the isentropic flow relations, the total temperature drop across the expansion wave can be calculated as
T t , 1 T t , 0 = 1 + γ − 1 2 M 1 2 ( 1 + γ − 1 2 M 1 ) 2 .
Since it is desirable to minimize losses of total properties and keep them close to the conditions set before the start of the run, it is necessary to keep the Mach number in the driver tube as close to zero as possible, ideally M 1 < 0.05 . It is possible to calculate the Mach number inside the tube by equating the mass flow rate through the nozzle, Equation (1), to the mass flow rate in the driver tube:
m ˙ = ρ t , 0 π D 2 4 γ R T t , 0 M 1 1 + γ − 1 2 M 1 1 + γ 1 − γ ,
where D is the driver tube diameter [m]. While a 78 mm driver tube diameter would satisfy the M 1 < 0.05 condition, a 4-inch diameter tube was chosen for the driver, corresponding to a driver Mach number of M 1 = 0.032 . The driver tube is constructed out of 4-inch Tri Clamp 304 stainless steel spools (internal diameter D = 97.4 mm) arranged in a bi-fold configuration with a total length of 50 feet (15.2 m), as shown in Figure 1. This length allows for about 100 ms total expansion wave travel time. The Tri-Clamp assembly of this size is rated to 800 psi, according to the manufacturer. However, the entire driver tube assembly was hydro-tested to 400 psi, and the maximum working pressure was limited to 100 psi. Such modular architecture allows for an easy modification of the driver section of the tunnel in the future. A summary of the main tunnel specifications is presented in Table 1.
Table 1. Summary of the main tunnel specifications and the generated freestream flow parameters. The flow parameters are shown for the first steady-state test period. More information about the experimentally determined values can be found in Section 5.
The fast-acting valve (FAV) is a critical element of this design, which facilitates rapid, disassembly-free tunnel resets. The FAV was custom-built by Max-Air Technology, Inc. (Wentzville, MO, USA) based on their off-the-shelf DeltaT 050/051 Series butterfly valve. In order to reduce the cost and the FAV opening time, a 3 in. nominal size (2.5 in. opening diameter) was chosen for the design. The valve is driven by a MT26 rack and pinion pneumatic actuator set in the fail-open configuration. In other words, the valve is closed only when the control air at 80 psi is supplied. The control gas is provided through a normally closed solenoid valve, which is controlled remotely with a 24 V DC power supply. The valve opening is triggered with a 5 V signal from an external trigger box, which is supplied to a normally closed solid-state relay, rapidly cutting the power to the control solenoid and stopping the control air flow to the FAV. The FAV opening time quoted by the manufacturer and measured in the lab was around 19 ms and 14 ms, respectively. The total delay between the trigger signal and the beginning of the flow, as observed by the high-speed schlieren, was measured at (71.0 ± 0.5) ms.
The axisymmetric nozzle, milled from a single piece of 316 stainless steel, was connected to the FAV through an expansion joint (EJ) and set inside the test section (TS) as a free jet. Figure 2a shows the CAD renderings of the nozzle assembly with flange attachments. The test section was welded from 304 stainless steel panels and has a 6 in. × 6 in. cross-section with a 740 mm length. The four identical doors with 70 mm × 250 mm UV-fused silica windows allow for good optical access, as shown in Figure 2b.
Figure 2. CAD rendering of: (a) nozzle with two attached flanges; (b) test section.
The tunnel can be operated with either compressed air or a broad range of bottled compressed gases, including nitrogen, carbon dioxide, inert gases, and nitric oxide, due to all wetted areas of the tunnel being made out of Viton, PTFE, or stainless steel. The filling and vacuum infrastructure will be upgraded in the near future to accommodate safe operation with nitric oxide mixtures. In the work presented here, the tunnel was operated with nitrogen as a test gas in order to improve FLEET measurement performance. In addition to accommodating optical diagnostics, the tunnel is instrumented with pressure transducers. A Kulite XCL-100-7BARA transducer is used for stagnation pressure measurements directly upstream of the nozzle, while a Kulite XCQ-093-5A is installed 5mm upstream of the nozzle exit plane to measure static pressure at the exit. Figure 3 shows representative pressure traces for the conditions used in this work, with the magenta region indicating the tunnel start-up lasting for about 30 ms. The periodic nature of the Ludwieg tube operation is evident in the stagnation pressure reading, with the repeated expansion wave arrival indicated by the total pressure drop occurring in 100 ms intervals. The static pressure rise after the 275 ms mark is attributed to a gradual filling of the vacuum chamber past the nominal static pressure and signals the beginning of tunnel unstart, which takes an additional 300 ms. Signals from both pressure sensors are processed by KSC-1-BU4 high-performance signal conditioners with a 25 kHz low-pass filter applied and are recorded via a National Instruments NI-9201 DAQ with a maximum dual-channel sampling rate of 250 kS/s.
Figure 3. Stagnation and static pressure traces collected during Run 10. The magenta region indicates tunnel start−up, and the cyan regions indicate the steady−state test times.

3. Nozzle Design and Numerical Analysis

A few different methods exist for supersonic nozzle design, ranging from analytical [22] to CFD-based solutions [23]. In this work, a more conventional method of characteristics (MOC) combined with a boundary layer correction and subsequent CFD design validation was chosen for its robustness for Mach numbers under 8 [24] and relative computational simplicity [25].
The 2D axisymmetric solver portion of the NASA Three-Dimensional Nozzle Design MOC code [26] was used to design the supersonic part of the nozzle. Relevant technical details of the program are explained in the related document by Rice [27]. The MOC_GRID_BDE subroutine of [26] was used to generate the nozzle contour. Options used for the calculation include: a perfect axisymmetric nozzle type, exit Mach number of 4.1 to account for boundary layer growth, and 101 characteristic lines. No specific throat conditions were specified except the normalized upstream and downstream throat radii of curvature, which were both set to 1. Despite the code calculating only the diverging part of the nozzle, it takes the upstream throat curvature into account to define the initial data line, given the total flow conditions. A small throat radius of curvature was chosen to minimize the total nozzle length [25].
After simulation, the resulting nozzle contour file output from the program included all points downstream of the nozzle throat in the diverging section. These points were then imported into SolidWorks 2024 and dimensioned. Since the quality of the flow is primarily determined by the throat and diverging sections of the nozzle, the converging section was designed to be conical with smooth transitions at the inlet and throat [28]. Both transitions were matched to the radius of curvature of the diverging section near the throat, making the throat geometry symmetric. The resulting contour of the nozzle is shown in Figure 4.
Figure 4. Dimensioned nozzle contour, including a converging section.
Subsequently, the SolidWorks geometry was imported into Fidelity Pointwise, where a quadrilateral-structured mesh with 522,952 total cells was constructed. Separate mesh regions were created for the converging and diverging sections of the nozzle for more control over the boundary layer region. Mesh dimensions for each section are given in Table 2, and the resulting interface is shown in Figure 5.
Table 2. Mesh dimensions and cell count.
Figure 5. Nozzle mesh showing the converging and diverging domains separated by the throat boundary.
The Jacobian ratio for all cells in the mesh was positive, indicating no malformed elements. Inside the boundary layer cells, the aspect ratio reached a maximum of 2694. For non-wall-adjacent cells, this value was much lower, typically ranging from 2 to 30. Maximum equiangular skewness was 0.223, which is classified as “excellent” using the Ansys skewness mesh metrics ([29], p. 593).
At each vertical boundary (inlet, throat, and outlet), the cell distribution parameters shown in Table 3 were used to create a high-resolution boundary layer region. All three vertical boundaries had 500 total points, 50 of which were used specifically in the boundary layer region with a set growth rate parameter. The 450 vertical points outside of the boundary layer at each station were set with a tanh distribution. Horizontal spacing of all points in both mesh domains (converging and diverging) was set to be equidistant on the nozzle centerline.
Table 3. Cell distribution parameters used in the boundary layer region.
After initializing and solving the mesh, it was imported into Ansys Fluent 2025 R1. Based on existing literature [30,31,32], the k–ω shear stress transport (SST) Reynolds-averaged Navier–Stokes (RANS) model was selected, as it best matches experimental pressure data in similar facilities. For simplicity, a transitional model was not used. Use of the SST model is also recommended by the RANS turbulence modeling guide offered by Ansys Fluent ([33], p. 10).
Pressure inlet, adiabatic wall, and pressure outlet boundary conditions were set in Fluent, along with the axisymmetric symmetry option. Boundary condition parameters used in the simulation are shown in Table 4. The inlet pressure was set by the maximum working pressure of the tunnel, and the outlet pressure was set by the vacuum tank, with the outlet temperature computed using isentropic relations. Following previous computational ([34], p. 1636) and experimental ([11], p. 13) results, a turbulence intensity of 1% was selected. The turbulence length scale was estimated based on the laminar boundary layer thickness ([29], p. 1442).
Table 4. Boundary condition parameters at the inlet and outlet.
For the simulation, a two-dimensional, axisymmetric, and density-based solver was selected. The working fluid was set to air, using an ideal gas density and Sutherland’s law of viscosity. As stated previously, a non-transitional k–ω SST model was used with compressibility effects enabled. Solver controls included: the Roe Flux-Difference Splitting (FDS) scheme, second-order upwinding, and a Courant–Friedrichs–Lewy (CFL) number of 1. To provide suitable initial conditions for the viscous solver, 5-level full multigrid (FMG) initialization ([29], p. 3744) was used, after which an inviscid solver was run for 6700 iterations. Subsequently, the viscous model ran for 23,400 iterations using the inviscid solution as an initial condition. In order to accurately resolve the viscous sublayer near the wall without the use of wall functions, a y + value near 1 is required, as recommended in ([35], p. 153). For this reason, the mesh was iteratively refined until a maximum value of y + = 1.3 was encountered at the wall, and the cell growth rate reported in Table 3 was selected such that ~30 cells were placed fully within the boundary layer region to ensure sufficient overall boundary layer resolution ([35], p. 138). The viscous solution was considered converged after the residuals and a static pressure monitor placed on the nozzle centerline reached steady-state.
CFD results for static temperature, axial velocity, and Mach number are shown in Figure 6. Parameters of interest on the nozzle centerline at the exit plane include: static temperature T = 69.7 K, stagnation temperature T 0 = 293.2 K, Mach number M = 4.01 , and axial velocity v = 670.7 m/s. These values compare favorably with the experimental results reported for the same quantities in Section 5, and the results are summarized in Table 5. Figure 7 displays the Mach number and velocity at the exit plane of the nozzle, illustrating a relatively homogeneous exit Mach number of 4 outside the boundary layer. The 99% boundary layer thickness at the exit plane was calculated as δ 99 = 3.37 mm using the maximum freestream velocity as reference.
Figure 6. CFD results displaying static temperature, axial velocity, and Mach number inside the nozzle.
Table 5. Comparison between CFD and experimental results (see Section 5 for experimental uncertainties).
Figure 7. CFD results for Mach number and axial velocity profiles at the exit plane of the nozzle, the latter of which was used to find the 99% boundary layer (BL) thickness of δ 99 = 3.37 mm.

4. Optical Diagnostics

Simultaneous optical diagnostics of this characterization work consisted of femtosecond laser electronic excitation tagging (FLEET) and high-speed dot-schlieren. Schlieren provided the necessary information to measure the real-time Mach number of the core flow based on the shock angle near the 30° cone model, while FLEET provided a velocity measurement. Combined, velocity and Mach number measurements led to the calculation of static temperature. Assuming the known inert flow composition, this information is enough to fully define the thermodynamic state of the gas. Figure 8 presents a schematic of the optical setup for the simultaneous diagnostics, as well as placement of the axisymmetric conical model.
Figure 8. Schematic of the optical setup for simultaneous FLEET and dot-schlieren. L1—Mayima-Sekor 45 mm f/2.8 lens; LA—limiting aperture; OAP—off-axis parabolic mirror; L2—100 mm focal length aspherical lens; SHG—second harmonic generator; L3—250 mm UV-fused silica lens.

4.1. FLEET

A Spectra-Physics Solstice ACE (Spectra-Physics; Milpitas, CA, USA) was used as the laser source for velocity measurements via FLEET. Its fundamental 800 nm beam with an average pulse energy of 5.5 mJ/pulse and duration of around 100 fs was routed through a second harmonic generator (SHG) to generate a 400 nm output at 1.4 mJ/pulse. The beam was then focused vertically through the top window of the test section with a 250 mm focal length, 50.4 mm diameter UV-fused silica lens. The focusing lens was mounted on a translation stage to map the velocity across the core flow by vertically moving the focal point of the femtosecond laser. The final mirror and focusing lens were translated along the flow direction, both upstream and downstream, to probe different axial locations within the flow. Due to a number of optical elements and a thick test section window, the laser pulse energy dropped to around 1 mJ/pulse inside the test section. FLEET emission was captured by a pco.dicam C1 camera integrated with a GaAs intensifier and equipped with a 500 nm longpass filter. The camera was set up to integrate multiple intensifier gates on a single camera image and was synchronized with the laser to capture either every second (500 Hz) or every third laser pulse (333 Hz), depending on the size of the region of interest. FLEET signal intensity and decay rate benefited from the nitrogen test gas, which allowed capturing the FLEET signal at relatively long delays of up to 16 μs. Table 6 summarizes the intensifier gate widths and delays (with respect to the laser pulse) that were integrated on each captured image.
Table 6. Intensifier gates used for FLEET.

4.2. Schlieren

The schlieren imaging system was designed to serve as a default diagnostic for most of the tunnel runs. A few design considerations aiming to have a permanent schlieren setup that does not interfere with other measurements were: a rail system allowing movement without major realignment, a compact form factor to fit the necessary equipment for other diagnostics (e.g., the pco.dicam C1 camera in this work), and multiple interchangeable light sources across the visible spectrum that allow the selection of a wavelength with the most convenient spectral signal separation from other experiments.
The pitch side of the schlieren system uses an LDP-V 240-100 pulsed LED driver (PicoLAS GmbH, Würselen, Germany) to generate 200 ns pulses at up to 1 MHz rates. The pulse rate in this work was limited to 10 kHz as that was sufficient to visualize tunnel start, unstart, and the steady-state shock structure. The 450 nm to 470 nm light from the LED is focused through a limiting aperture using a Mamiya-Sekor 45 mm f/2.8 telephoto lens. A protected aluminum 30° off-axis parabolic (OAP) mirror is used to collimate the light through the test section, and another is used to collect and focus the light on the catch side. Both mirrors have a 101.6 mm diameter and 326.7 mm effective focal length. The light is then focused through an opaque dot, allowing any deviated light to appear brighter on the resulting image [18]. The light is collected with a 100 mm aspherical lens and imaged with a Photron SA5 high-speed camera. The aspherical lens allows the schlieren image to be brought into focus. The timing of the system is based on a trigger sent from the camera to the pulsed LED before exposure.
The OAPs were selected instead of conventional parabolic mirrors to reduce the comatic aberration that comes with pitching curved mirrors with respect to the collimated light. The focal point of the OAPs is removed from the collimated light due to the characteristic angle of the mirror, removing the need to pitch either mirror. This allows for a more compact “C” arrangement of the schlieren setup rather than a more conventional “Z” configuration [36].

5. Results and Discussion

The first part of the facility characterization was the Mach number measurement based on the high-speed schlieren visualization. Figure 9a shows a representative single-shot dot-schlieren image of the flowfield near a 30° cone model. It is worth noting that due to the dot-schlieren nature of evenly highlighting density gradients in all directions, both oblique shocks near the model have a similar appearance, and the resulting image has a vertical symmetry around the flow centerline. Two additional, weaker oblique shocks are produced near the nozzle exit by the forming shear layers of the free jet, as can be seen on the very top and bottom of the schlieren image.
Figure 9. Mach number extraction algorithm: (a) raw single-shot schlieren image; (b) cropped schlieren image after Sobel edge detection; (c) line identification and shock angle extraction done with a Hough transform.
The Mach number is calculated based on the measured oblique shock wave angles near the model and the Taylor–Maccoll definition of conical shock angle. The shock and the model edge angles were extracted on a single-shot basis from the 10 kHz schlieren data across about 0.5 s of supersonic flow time following the algorithm shown in Figure 9. The algorithm consisted of the following steps: cropping the schlieren image to only contain the conical part of the model and the two oblique shocks; applying a Sobel edge detection subroutine to identify the high-intensity gradient regions of the image and store them in a binary format, shown in Figure 9b; and the application of a Hough transform with appropriate length and angle thresholds to identify continuous lines, highlighted in red in Figure 9c. Once the line information is extracted, both the shock and the body angles are averaged over either 20 (500 Hz) or 30 (333 Hz) frames to match the repetition rate of the FLEET system during the specific run. The averaged angles are then supplied to the Taylor–Maccoll subroutine to identify the Mach number [17].
Figure 10 shows the evolution of the measured Mach number over the first 400 ms for four consecutive tunnel runs. The average Mach number for the duration of the run was 3.96 ± 0.03, with the single measurement values ranging between 3.89 and 4.07 with a standard deviation of 0.03. It is worth noting that the Mach number variations are repeatable from run to run and are synchronized with the expansion wave passages. Currently, it is hypothesized that the expansion wave passage disturbs the separation bubble formed at the exit of the nozzle, resulting in a small variation in the flow Mach number.
Figure 10. Mach number evolution, extracted for four consecutive runs, shows good repeatability and stability of the flow conditions.
The second part of the tunnel characterization was FLEET velocimetry, which was performed simultaneously with the high-speed schlieren discussed above. Figure 11 shows a representative single-shot FLEET image with three distinct vertical lines corresponding to the three intensifier gates noted in Table 6, along with the resulting binned FLEET intensity profile displayed on the bottom. The tagged line locations were extracted from the intensity profiles by applying a Gaussian fitting function. The velocity is then computed by dividing the line displacement by the time delay between the intensifier gate centers. More information about typical FLEET data post-processing can be found in the following references [37,38]. Primary sources of error associated with the utilized post-processing algorithm can be divided into two categories: random and systematic. Random errors primarily originate from FLEET signal level fluctuations due to flow and laser beam shot-to-shot fluctuations and intensifier noise. These errors are accounted for by the Gaussian fitting 95% confidence interval, which is reported below. The systematic errors may include finite signal decay, altering the recorded line profiles, and spatial scale calibration. Due to the very long fluorescence lifetime of FLEET in nitrogen on the order of a few 10 s of microseconds, the signal decay correction was estimated to be negligible and was not considered here [39]. Spatial scale calibration errors were minimized by utilizing reference scales and engineering best practices.
Figure 11. A representative single-shot image of FLEET lines (top); integrated signal intensity profile with Gaussian line fitting (bottom).
Figure 12 shows both the measured centerline velocity 10 mm downstream from the nozzle exit plane and the calculated Mach number for one of the representative runs plotted together. The magenta rectangle designates the flow-establishing region with a significantly higher velocity than expected. It is worth noting that the velocity evolution captures the expansion wave passages manifested with velocity drops near the 100 ms, 200 ms, and 300 ms time stamps. These velocity drops closely match the total pressure drops shown in Figure 3. Additionally, it can be seen that the measured velocity exhibits discrete deceleration at each expansion wave passage, attributed to the cooling of the gas in the driver tube. During the first steady test time, average velocity was measured to be (668.0 ± 5.7) m/s. During the second, third, and fourth test intervals, the average velocity dropped to (661.0 ± 5.3) m/s, (656.0 ± 5.3) m/s, and (650.0 ± 5.4) m/s, respectively.
Figure 12. Synchronized velocity and Mach number results plotted for Run 10.
Static flow temperature can be calculated from the coupled velocity and Mach number measurements, given a known ratio of the specific heats and gas composition, following the equation: T st = ( γ R ) − 1 ( V / M ) 2 . As was stated in Section 2, the ratio of specific heats, γ , for nitrogen across the entire range of temperatures and pressures is equal to 1.40, according to the tabulated data from Hilsenrath et al. [20]. Figure 13 shows the calculated static temperature evolution in the core flow across the test time for Run 10 of the tunnel. Due to high velocity during the tunnel start-up phase, the static temperature within the magenta rectangle is higher than expected. During the test time, the static temperature is relatively stable, with the average value ranging between (68.6 ± 0.3) K and (66.3 ± 0.3) K for the first and last stable test intervals, respectively.
Figure 13. Calculated static temperature evolution for Run 10.
Since the expansion through the nozzle is assumed to be isentropic, the total temperature within the driver tube can be calculated based on the measured Mach number and the static temperature presented above. Figure 14 shows the total temperature evolution inside the driver tube for Run 10. Here, the discrete temperature drops are evident, similar to the velocity measurement above. The total temperatures for each of the four steady test times were calculated at: (286.0 ± 1.6) K, (281.0 ± 1.8) K, (277.0 ± 1.3) K, and (273.0 ± 1.5) K. These values compare well with the theoretical total temperature drop across a single expansion wave passage of 1.2%, as calculated using Equation (6). From here, the total temperature of nitrogen after the driver filling can be recovered at around 290 K as an additional check for the characterization. This measured temperature is slightly lower than the standard laboratory temperature of 293 K, likely because insufficient time elapsed after filling the driver from the compressed gas bottle for the gas to fully equilibrate to laboratory conditions.
Figure 14. Calculated total temperature evolution of the gas in the driver tube for Run 10.
The next part of the characterization was the spatial mapping of the velocity distribution across the core flow, which was performed by scanning the FLEET filament radial position around 10mm downstream from the nozzle exit plane. Figure 15 presents the velocity results as a function of radial position, with the 0mm location corresponding to the flow centerline and Run 10 results discussed above. The positive radial position designates vertical displacement towards the top test section window. Overall, the collected data shows a symmetric velocity profile with the core flow spanning −25 mm to 25 mm radial positions. Outside the core flow, a gradual decrease in flow velocity is observed due to the propagation of the oblique shocks from the edge of the nozzle, which are visible in Figure 9. Over time, the velocity gradually decreases across the entire flowfield, matching the trends presented in Figure 12. During the last time interval shown in orange, the tunnel begins to unstart, and the oblique shocks originating from the nozzle edge begin to recess further upstream, shrinking the core flow diameter. The velocity was not measured further up from the centerline due to the femtosecond beam interaction with the top window, which prevented reliable flow tagging.
Figure 15. Spatial velocity distribution across the flowfield at four time intervals.
Lastly, the flow velocity was measured 30mm downstream from the nozzle exit plane along the centerline to further characterize the flowfield. Figure 16 presents the velocity evolution of three consecutive runs at this downstream location. As can be seen, the flow conditions are repeatable from run to run, and the velocity exhibits the same magnitude and behavior as the upstream location shown in Figure 12. Additionally, it could be noted that the further downstream location is affected by tunnel unstart earlier than the upstream locations discussed above due to the slow recession of the oblique shocks formed at the nozzle exit. The unstart time interval is designated with the gray box in Figure 16 between 300 ms and 400 ms.
Figure 16. Single-shot velocity evolution, extracted for three consecutive runs at the 30 mm downstream position along the centerline, shows good repeatability and stability of the flow conditions. The magenta region indicates tunnel start-up, and the gray region indicates tunnel unstart.

6. Conclusions

This article presents the architecture, design considerations, and characterization of the new Bench-top Ludwieg tube for Aerodynamic Measurement (BLAM), which was constructed at Texas A&M University to address the need for a high-duty-cycle supersonic ground-testing facility capable of generating relevant flow conditions for both optical diagnostic development and fundamental aerodynamic testing. The tunnel was designed based on a Ludwieg tube architecture, which proved to be a robust and cost-effective solution. The fast-acting valve, with an opening time of 14 ms, allows for fast tunnel reset times of only 10–15 min, limited by the vacuum system throughput, which will be improved in the future.
Freestream flow conditions were characterized via simultaneous measurements of pressure, velocity, and Mach number. The average velocity during the first steady test time was measured at (668.0 ± 5.7) m/s. The Mach number was measured simultaneously at 3.96 ± 0.03. Both the velocity and Mach number had single-shot fluctuations not exceeding 0.8%. Freestream static temperature was calculated based on the measured velocity and Mach number to be (68.6 ± 0.3) K for the first steady-state time period. Velocity measurements across the flowfield revealed a uniform velocity distribution across the −25 mm to 25 mm radial distances from the centerline, which reduced after around the 300 ms mark due to tunnel unstart. Overall, the experimentally measured freestream flow conditions compare well with the original design requirements and the CFD simulation results. In the near future, the tunnel will be utilized for the development of diagnostic methods focusing primarily on measurements of fundamental flowfield properties, such as velocity and temperature, via femtosecond and dispersion-based techniques.

Author Contributions

Conceptualization, B.S.L.; methodology, B.S.L.; software, B.S.L. and N.G.P.; formal analysis, B.S.L.; investigation, B.S.L., R.Q.B., R.R. and F.S.; writing—original draft preparation, B.S.L., R.Q.B., N.G.P., R.R., F.S., A.D. and R.B.M.; writing—review and editing, B.S.L., R.Q.B. and N.G.P.; visualization, B.S.L. and N.G.P.; supervision, B.S.L. and R.B.M.; project administration, B.S.L. and R.B.M.; funding acquisition, B.S.L., A.D. and R.B.M. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by Texas A&M University internal funds.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors on request.

Acknowledgments

The authors would like to thank Sergey B. Leonov and Jacob Vaughn for their valuable input in discussions. The authors would also like to thank John Kochan for his help during tunnel construction.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Schmisseur, J.D. Hypersonics into the 21st century: A perspective on AFOSR-sponsored research in aerothermodynamics. Prog. Aerosp. Sci. 2015, 72, 3–16. [Google Scholar] [CrossRef] [Scilit]
  2. Kieweg, S.L.; Ray, J.; Weirs, V.G.; Carnes, B.; Dinzl, D.; Freno, B.; Howard, M.; Phipps, E.; Rider, W.; Smith, T. Validation Assessment of Hypersonic Double-Cone Flow Simulations using Uncertainty Quantification, Sensitivity Analysis, and Validation Metrics. In Proceedings of the AIAA Scitech 2019 Forum, San Diego, CA, USA, 7–11 January 2019. [Google Scholar] [CrossRef] [Scilit]
  3. Leyva, I.A. The relentless pursuit of hypersonic flight. Phys. Today 2017, 70, 30–36. [Google Scholar] [CrossRef] [Scilit]
  4. Oberkampf, W.L.; Smith, B.L. Assessment Criteria for Computational Fluid Dynamics Model Validation Experiments. J. Verif. Valid. Uncertain. Quantif. 2017, 2, 031002. [Google Scholar] [CrossRef] [Scilit]
  5. Holloway, M.E.; Chaudhry, R.S.; Boyd, I.D. Assessment of Hypersonic Double-Cone Experiments for Validation of Thermochemistry Models. J. Spacecr. Rocket. 2022, 59, 389–400. [Google Scholar] [CrossRef] [Scilit]
  6. Danehy, P.M.; Weisberger, J.; Johansen, C.; Reese, D.; Fahringer, T.; Paraziale, N.J.; Dedic, C.; Estevadeordal, J.; Cruden, B.A. Non-Intrusive Measurement Techniques for Flow Characterization of Hypersonic Wind Tunnels. In Proceedings of the STO-VKI-LS on “Flow Characterization and Modeling of Hypersonic Wind Tunnels”, Brussels, Belgium, 3–5 December 2018; The Von Karman Institute for Fluid Dynamics Lecture Series STO-AVT-325. pp. 1–140. [Google Scholar]
  7. Schneider, S.; Gaven, C. Mean flow and noise measurements in the Purdue Quiet-Flow Ludwieg Tube. In Proceedings of the 32nd Aerospace Sciences Meeting and Exhibit, Reno, NV, USA, 10–13 January 1994. [Google Scholar] [CrossRef] [Scilit]
  8. Lakebrink, M.T.; Bowcutt, K.G.; Winfree, T.; Huffman, C.C.; Juliano, T.J. Optimization of a Mach-6 Quiet Wind-Tunnel Nozzle. J. Spacecr. Rocket. 2018, 55, 315–321. [Google Scholar] [CrossRef] [Scilit]
  9. Kreth, P.A.; Gragston, M.; Davenport, K.; Schmisseur, J.D. Design and Initial Characterization of the UTSI Mach 4 Ludwieg Tube. In Proceedings of the AIAA Scitech 2021 Forum, Virtual, 11–15 & 19–21 January 2021. [Google Scholar] [CrossRef] [Scilit]
  10. Gragston, M.; Davenport, K.; Siddiqui, F.; Webber, N.; Smith, C.D.; Kreth, P.A.; Schmisseur, J.D. Design and Initial Characterization of the UTSI Mach 7 Ludwieg Tube. In Proceedings of the AIAA SCITECH 2023 Forum, National Harbor, MD, USA, 23–27 January 2023. [Google Scholar] [CrossRef] [Scilit]
  11. Hoffman, E.N.; LaLonde, E.J.; Andrade, A.; Chen, I.; Bilbo, H.A.; Combs, C.S. Flow Characterization of the UTSA Hypersonic Ludwieg Tube. Aerospace 2023, 10, 463. [Google Scholar] [CrossRef] [Scilit]
  12. Bashor, I.; Hoffman, E.; Gonzalez, G.; Combs, C.S. Design and Preliminary Calibration of the UTSA Mach 7 Hypersonic Ludwieg Tube. In Proceedings of the AIAA Aviation 2019 Forum, Dallas, TX, USA, 17–21 June 2019. [Google Scholar] [CrossRef] [Scilit]
  13. Andrews, P.S.; Lax, P.A.; Thomas, F.O.; Leonov, S.B. Visualization of sidewall vortices in rectangular nozzle supersonic blowdown wind tunnel. Phys. Fluids 2024, 36, 016136. [Google Scholar] [CrossRef] [Scilit]
  14. Dogariu, L.E.; Dogariu, A.; Miles, R.B.; Smith, M.S.; Marineau, E.C. Femtosecond Laser Electronic Excitation Tagging Velocimetry in a Large-Scale Hypersonic Facility. AIAA J. 2019, 57, 4725–4737. [Google Scholar] [CrossRef] [Scilit]
  15. Carter, D.W.; Gragston, M.; Leonov, B.S.; Parziale, N.; Rodrigues, N.S. Recent Developments and Applications of Molecular Tagging Velocimetry for High-Speed Flow Measurements. In Proceedings of the AIAA SCITECH 2026 Forum, Orlando, FL, USA, 12–16 January 2026. [Google Scholar] [CrossRef] [Scilit]
  16. Settles, G.S. Schlieren and Shadowgraph Techniques; Springer: Berlin/Heidelberg, Germany, 2001. [Google Scholar] [CrossRef] [Scilit]
  17. Saenz, L.; Frankel, J.; Gross, A.; Shu, F. Design and flow characterization of the Mach 5 shock tunnel at New Mexico State University. Shock Waves 2025, 35, 437–450. [Google Scholar] [CrossRef] [Scilit]
  18. Leonov, B.S.; Siddiqui, F. Laser Spark Velocimetry in Hypervelocity Expansion Tunnel Using a 250 kHz Dot-Schlieren. In Proceedings of the AIAA SCITECH 2025 Forum, Orlando, FL, USA, 6–10 January, 2025. [Google Scholar] [CrossRef] [Scilit]
  19. Pope, A.; Gion, K. High-Speed Wind Tunnel Testing; Wiley: New York, NY, USA, 1965. [Google Scholar]
  20. Hilsenrath, J.; Beckett, C.; Benedict, W.; Fano, L.; Hoge, H. Tables of Thermal Properties of Gases; Technical Report, NBS-NACA; U.S. Government Printing Office: Washington, DC, USA, 1955. [Google Scholar]
  21. Zel’dovich, Y.B.; Raizer, Y.P. Physics of Shock Waves and High-Temperature Hydrodynamic Phenomena; Academic Press: New York, NY, USA, 1966; Volume 1. [Google Scholar] [CrossRef] [Scilit]
  22. Foelsch, K. The Analytical Design of an Axially Symmetric Laval Nozzle for a Parallel and Uniform Jet. J. Aeronaut. Sci. 1949, 16, 161–166. [Google Scholar] [CrossRef] [Scilit]
  23. Matsunaga, M.; Fujio, C.; Ogawa, H.; Higa, Y.; Handa, T. Nozzle design optimization for supersonic wind tunnel by using surrogate-assisted evolutionary algorithms. Aerosp. Sci. Technol. 2022, 130, 107879. [Google Scholar] [CrossRef] [Scilit]
  24. Benton, J.; Edwards, A.; Perkins, J. Limitations of the method of characteristics when applied to axisymmetric hypersonic nozzle design. In Proceedings of the 28th Aerospace Sciences Meeting, Reno, NV, USA, 8–11 January 1990. [Google Scholar] [CrossRef] [Scilit]
  25. Cakir, B.O.; Gyenge, A.; Grossir, G. Design, integration and characterization of a Mach 5 axisymmetric contoured nozzle for the VKI-H3 hypersonic tunnel. Aerosp. Sci. Technol. 2025, 158, 109894. [Google Scholar] [CrossRef] [Scilit]
  26. Rice, T. Three-Dimensional-Nozzle-Design-Code; NASA: Greenbelt, MD, USA, 2020. [Google Scholar]
  27. Rice, T. 2D and 3D Method of Characteristic Tools for Complex Nozzle Development—Final Report; Technical Report RTDC-TPS-48 I; Johns Hopkins University Applied Physics Laboratory: Laurel, MD, USA, 2003. [Google Scholar]
  28. Singh, J.; Zerpa, L.E.; Partington, B.; Gamboa, J. Effect of nozzle geometry on critical-subcritical flow transitions. Heliyon 2019, 5, e01273. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Ansys. Ansys Fluent User’s Guide: 2025 R2; Technical Report; Ansys, Inc.: Canonsburg, PA, USA, 2025. [Google Scholar]
  30. Balabel, A.; Hegab, A.; Nasr, M.; El-Behery, S.M. Assessment of Turbulence Modeling for Gas Flow in Two-Dimensional Convergent–Divergent Rocket Nozzle. Appl. Math. Model. 2011, 35, 3408–3422. [Google Scholar] [CrossRef] [Scilit]
  31. Zaheer, S.Q.; Disimile, P.J. Design and Parametric Analysis of a Mach 4 Wind Tunnel for SSLCs Studies. J. Fluids Eng. 2022, 144, 101209. [Google Scholar] [CrossRef] [Scilit]
  32. Leon-Cardona, D.; Rosso-Ceron, A.M.; Rodriguez-Ferreira, J.; Del Jesus Matinez, M.; Sanguino-Barajas, P.A. Assessment of RANS Turbulence Models for the Simulation of Turbulent Compressible Flows in Convergent-Divergent Nozzles. Chem. Eng. Trans. 2024, 111, 505–510. [Google Scholar] [CrossRef]
  33. Menter, F.R.; Lechner, R.; Matyushenko, A. Best Practice: RANS Turbulence Modeling in Ansys CFD; Technical Report Version 1; Ansys, Inc.: Canonsburg, PA, USA, 2021. [Google Scholar]
  34. Hu, J.; Rizzi, A. Turbulent Flow in Supersonic and Hypersonic Nozzles. AIAA J. 1995, 33, 1634–1640. [Google Scholar] [CrossRef] [Scilit]
  35. Ansys. Ansys Fluent Theory Guide: 2025 R2; Technical Report; Ansys, Inc.: Canonsburg, PA, USA, 2025. [Google Scholar]
  36. Zheng, L.; Susa, A.J.; Hanson, R.K. Methodology of designing compact schlieren systems using off-axis parabolic mirrors. Appl. Opt. 2022, 61, 4857. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. Danehy, P.M.; Burns, R.A.; Reese, D.T.; Retter, J.E.; Kearney, S.P. FLEET Velocimetry for Aerodynamics. Annu. Rev. Fluid Mech. 2021, 54, 525–553. [Google Scholar] [CrossRef] [Scilit]
  38. Pehrson, J.C.; Leonov, B.S.; Melone, K.; Lakebrink, M.T.; Bowersox, R.; Miles, R.B.; Limbach, C.M. Hypersonic FLEET velocimetry and uncertainty characterization in a tripped boundary layer. Meas. Sci. Technol. 2024, 35, 015206. [Google Scholar] [CrossRef] [Scilit]
  39. Gragston, M. Computational Analysis of Motion Blur Correction for Molecular Tagging Velocimetry. AIAA J. 2025, 63, 3689–3699. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.