Abstract
Background/Objectives: Universal-shade resin composites (USRC) simplify shade selection, but their high translucency may limit their ability to hide a dark substrate. This exploratory in vitro study compared the color change produced by five USRC over stained tooth substrates at two thicknesses and with an opaque blocking layer, and how closely the covered specimens matched the original tooth color. Methods: Five tea-stained bovine teeth with comparable lightness were selected. Zenchroma, A-UNO, Vitra, Transcend, and Omnichroma were tested as unbonded disks of 0.5 mm, 0.5 mm over a 0.5 mm opaque blocker, and 1.0 mm. Five disks per material and configuration were measured over all five teeth with a clinical spectrophotometer. The color change relative to the stained tooth was calculated as ΔEab. In an analysis introduced during peer review, the color difference from the pre-staining color of each tooth was calculated as ΔE00. Disk-averaged values (n = 5) were analyzed by two-way ANOVA with Bonferroni-adjusted comparisons (α = 0.05). Results: Material, configuration, and their interaction significantly affected both outcomes (all p < 0.001). Mean ΔEab ranged from 32.73 (A-UNO) to 43.40 (Vitra) and increased from 0.5 mm (36.61) to blocker + 0.5 mm (37.50) and 1.0 mm (39.86). No configuration matched the original tooth color within the acceptability threshold (ΔE00 ≤ 1.8). The blocker configuration showed the smallest difference from the original color for every material (ΔE00 3.65–6.96), and A-UNO, despite the smallest color change, was closest in every configuration. Conclusions: In this unbonded laboratory model, a larger color change did not indicate a closer match to the original tooth color. The blocker observation requires validation under standardized measurement conditions before clinical recommendations can be made.
1. Introduction
Direct resin composite restorations are widely used in esthetic dentistry because they conserve tooth structure, can be repaired, and let the clinician control the final color at the chair. The color of a tooth arises from the combined optical behavior of enamel and dentin. It can be altered intrinsically by pulp necrosis, trauma, medications, fluorosis, and aging, and extrinsically by dietary chromogens such as those in tea and coffee [1]. When the discoloration lies within the tooth itself, a restoration must do more than match the neighboring teeth; it must also suppress the dark substrate beneath it. Masking of discolored tooth substrate is quite challenging with minimally invasive preparations, where the space available for restorative material is often 1 mm or less.
RC materials are inherently translucent and their ability to conceal an underlying substrate depends on both their composition and their thickness. Studies of conventional opaque and dentin shades found that RC layers of 1 mm or less were not capable to mask a black background, whereas thicker layers or dedicated opaque shades masked it far more effectively [2]. A recent study reported that an opaque single-shade material masked stained tooth-colored backgrounds at about 0.5 mm but required at least 1.5 mm to mask intraoral darkness [3]. Masking has therefore traditionally relied on layering opaque, dentin, and enamel shades, a technique that requires careful shade selection, several syringes of material, and considerable operator skill.
Single-shade, or universal-shade, resin composites (USRC) were developed to simplify this process. A single material is designed to match a wide range of VITA shades through its color adjustment potential (CAP), often described as the “chameleon effect” [4,5]. CAP has a physical component, related to translucency and light transmission, and a perceptual blending component, and it varies with both the composite and the surrounding shade [6]. Manufacturers achieve this CAP in different ways. For example, Omnichroma uses uniformly sized spherical fillers of about 260 nm that produce structural color by selectively reflecting red-to-yellow wavelengths, without added pigments [7,8]. Other products, including A-UNO, Zenchroma, Transcend, and Vittra APS Unique, combine filler designs, close matching of filler and matrix refractive indices, and small amounts of pigment. Compared with group-shade composites, USRC transmit more light and scatter and absorb less [9]. In vitro studies of restorations placed in denture and acrylic teeth have reported that the color matching of USRC depends on the material and on the shade of the surrounding tooth; matching was generally better with lighter shades, and in one study a single-shade composite matched less well than multi-shade universal composites [10,11]. A recent systematic review likewise found wide variation between products and study designs [12].
The high translucency that allows USRC to blend may become a drawback over a discolored substrate. Their color matching is generally better on lighter backgrounds, which reflect more light through the restoration [13]. Restoration thickness also influences both color matching and masking [14]. Yamashita et al. showed that the thickness of USRC governs how much of the background dentin color shows through, which makes the final color hard to predict in cavities of varying depth [7]. For dark or discolored backgrounds, some manufacturers supply a separate opaque material, such as Omnichroma Blocker, to be placed as a thin masking layer beneath the single-shade composite [12]. However, few studies have examined how this combination affects the final color of the restoration; most have tested the masking ability of the opaque material alone [15].
Three questions therefore remain open. First, most CAP studies have tested USRC on normally colored teeth, on composite backgrounds matched to shade tabs, or on standardized black, white, or C4 backgrounds, rather than on discolored tooth structure. Second, comparative data on several commercial USRC systems are limited, particularly for newer materials such as Transcend, A-UNO, and Zenchroma. In a recent comparison of four USRC, Vittra APS Unique showed the highest color-matching potential, whereas Zenchroma showed the lowest visual color adjustment against an A1 background [13]. Third, it is unclear whether placing a thin blocker under a thin layer of USRC offers any advantage over simply using a thicker layer of composite. The answer bears directly on preparation depth, chair time, and technique sensitivity. Because bovine teeth are an accepted substitute for human teeth in laboratory research [16], stained bovine specimens provide a standardized, tooth-derived substrate for addressing these questions.
The aim of this exploratory in vitro study was to evaluate the color change produced by five USRC (Omnichroma, A-UNO, Zenchroma, Transcend, and Vittra APS Unique) over experimentally discolored tooth structure, and how closely each configuration restored the original color of the tooth [17]. The study compares two ways of filling the same total thickness of 1.0 mm—a single composite layer, or an opaque blocker beneath a thinner composite layer—together with 0.5 mm of composite alone; different preparation depths were not tested, and these options were not compared with conventional dentin–enamel layering. The specific objectives were: (1) to compare the color change (ΔEab) produced by the five composites over tea-stained bovine tooth substrates; (2) to determine the effect of composite thickness (0.5 mm vs. 1.0 mm) on this color change; (3) to determine whether a 0.5 mm opaque blocker beneath 0.5 mm of composite alters the color change compared with 1.0 mm of composite at equal total thickness; and (4) to determine how closely each configuration restored the pre-staining color of the tooth (ΔE00; an analysis introduced during peer review). The null hypotheses were that (i) material type, (ii) composite thickness, and (iii) the addition of a blocking layer would have no significant effect on the color change produced over discolored tooth structure or on the color difference from the original tooth color.
2. Materials and Methods
2.1. Materials
This in vitro study obtained ethical approval from the Research and Ethical Committee of RAK Medical and Health Sciences University, UAE, and (RAKCODS-REC-10-2024-25-F) prior to staring the experiment. Five USRC and one opaque blocker tested in this experiment are shown in Table 1. The required sample size for each material (n = 5) was calculated using G*Power statistical software (version 3.1.9.7). An a priori power analysis for an ANOVA model was performed using an effect size f = 0.8 [18], α = 0.05, estimated power (1 − β) = 0.8, numerator degrees of freedom (df) = 5, and number of groups = 5.
Table 1.
Descriptions of the tested materials.
2.2. Specimen Preparation
Freshly extracted bovine incisors were stored refrigerated at negative 5 degrees centigrade until use. All teeth were first cleaned with a periodontal scaler and examined under a stereomicroscope at ×10 magnification and by transillumination with an LED light source; teeth showing cracks, fractures, enamel defects, caries, unusual discoloration, or other structural irregularities were excluded. Before preparation, the teeth were placed in warm water for 5 min and remaining soft tissue was removed with a scalpel. The labial enamel was flattened with 1000- and 1500-grit silicon carbide paper to leave approximately 1 mm of enamel and a test window of at least 7 × 7 mm. The palatal enamel was then removed completely with a diamond bur in a high-speed handpiece to expose the dentin, and the pulp tissue was removed. Exposure of dentin was confirmed visually under ×10 magnification by the change in color, and by a tactile change in hardness when probed with a dental explorer. This preparation followed the method described by Kyaw et al. [19].
2.3. Staining
Before staining, the color of the labial surface of each specimen was measured three times with a clinical spectrophotometer (VITA Easyshade Advance; VITA Zahnfabrik, Bad Säckingen, Germany), and the mean L*, a*, and b* values were recorded as the original color (O). A tea solution was prepared by steeping four tea bags (Lipton Yellow Label Black Tea, 2 g per tea bag; Lipton, United Arab Emirates) in 100 mL of boiling water for 5 min. Ten specimens were immersed in the solution and kept in an incubator at 37 °C for 7 days; the solution was renewed on day 4 to maintain a consistent chromogen concentration, compensate for evaporation, and limit microbial growth, following a previously published protocol [18]. The pH of the solution was not monitored. The specimens were then rinsed with tap water and air-dried. The color of the labial surface was measured three times with a clinical spectrophotometer (VITA Easyshade Advance; VITA Zahnfabrik, Bad Säckingen, Germany), and the mean L*, a*, b*, C*, and h values were recorded as the baseline (I). Specimens with uneven staining were excluded. To limit substrate variation, the five stained specimens whose L* values were within ±5 L* units of the mean (L* = 53.09 ± 2.66) were selected for the color-change evaluation. The five selected teeth (laboratory specimen numbers 4, 6, 10, 14, and 16) are referred to as T1–T5; their original and stained color coordinates are given in Table 2.
Table 2.
Color coordinates of the five tooth substrates before staining (original, O) and after staining (baseline, I), and the color difference produced by staining.
2.4. Fabrication of Composite Disks
Composite disks were made in custom 7 × 7 mm glass molds 0.5 mm and 1.0 mm thick and were compressed between glass slabs during curing to obtain flat, parallel surfaces. Five additional 0.5 mm disks were made from Omnichroma Blocker. The five blocker disks were randomly numbered 1–5. For each material, blocker disk n was paired with the composite disk bearing the same number (1–1, 2–2, 3–3, 4–4, 5–5), so that each composite disk was tested with only one blocker disk and the same five blocker disks were used under all five composites. Each composite disk was polymerized for 40 s using a light cure (Eighteeth Curing Pen, Changzhou Sifary Medical Technology Co., Ltd., Changzhou City, Jiangsu, China) with a light output of 1500 mW/cm2 according to the manufacturer’s instructions. The final thickness of each composite and blocker disk was measured with a digital caliper at three points, and disks deviating by more than ±0.05 mm from the nominal thickness were rejected and remade. All disks were inspected under a stereomicroscope at ×10 magnification, and disks with visible voids, cracks, porosities, or surface irregularities were discarded. The composite disks were neither bonded to the tooth specimens nor immersed in the staining solution. For each material, five disks were used in each layering condition. The color of each disk was measured three times and the mean L*, a*, b*, C*, and h° values were recorded as the material’s reference color (S). An attempt was also made to establish a masking reference by measuring the disks over standard white and black backgrounds; however, because of the high translucency of the 0.5 mm and 1.0 mm specimens, valid readings could not be obtained for all materials and thicknesses, and this approach was therefore not used.
2.5. Color Measurement
The experimental workflow is summarized in Figure 1. Each composite was tested under three layering conditions: Condition A: A 0.5 mm composite disk; Condition B: A 0.5 mm composite disk placed over a 0.5 mm Omnichroma Blocker disk; Condition C: A 1.0 mm composite disk. In each condition, the disk (or disk combination) was positioned over the 7 × 7 mm window of a stained specimen, and color was measured as described above (M). Each of the five disks per material and condition was measured over each of the five selected teeth, so that every material and condition was evaluated on the same set of substrates (25 readings per group; 375 readings in total). The disks were placed manually, without bonding, over the window of each specimen, and the spectrophotometer probe was positioned perpendicular to the center of the disk surface. No coupling medium or positioning device was used, contact pressure was not controlled, and the hydration state of the teeth was not standardized during measurement. The color change produced by coverage was expressed as the color difference between the stained baseline (I) and the covered specimen (M), calculated with the CIELAB formula:
where ΔL*, Δa*, and Δb* are the differences between M and I. A higher ΔEab therefore indicates a greater change in the appearance of the discolored substrate. Because ΔEab also reflects the intrinsic color of each material, a larger value does not necessarily indicate more complete suppression of the substrate color. ΔEab is therefore reported as the color change produced by coverage rather than as a direct measure of masking ability.
Figure 1.
Methodological flow of the experiment.
This analysis was introduced during peer review, using the pre-staining color measurements recorded before the experiment (Section 2.3). To determine how closely each configuration restored the original appearance of the tooth, the color difference between each covered specimen (M) and the original color of the same tooth (O) was calculated with the CIEDE2000 formula [ΔE00(original)]. Lower values indicate closer restoration of the original color, and values ≤ 1.8 were considered clinically acceptable, corresponding to the 50:50% acceptability threshold [20]. The percentage of the staining-induced color difference corrected by each configuration was calculated as [ΔE00(O, I) − ΔE00(O, M)]/ΔE00(O, I) × 100, and the ΔL*, Δa*, and Δb* differences between M and O were recorded to describe the direction of any residual mismatch. All color differences were calculated directly from the recorded L*, a*, and b* coordinates.
2.6. Statistical Analysis
Data were analyzed with SPSS Statistics 27.0 (IBM Corp., Armonk, NY, USA). The composite disk was considered the experimental unit. The five readings of each disk (one over each tooth) were averaged, giving one ΔEab value per disk (n = 5 per group; 75 values in total). Normality of residuals and homogeneity of variances were assessed with the Shapiro–Wilk and Levene tests, respectively. A two-way ANOVA examined the effects of material, layering condition, and their interaction on disk-level ΔEab. Because the interaction was significant, simple-effects analyses compared materials within each layering condition and layering conditions within each material, with Bonferroni adjustment for multiple comparisons. Partial eta squared (ηp2) was reported as the effect size, and data are presented as mean ± standard deviation (SD) with group-specific 95% confidence intervals (CI). The same analyses were applied to ΔE00(original). To examine substrate-related variability, a repeated-measures (split-plot) ANOVA was fitted to the 375 individual readings of each outcome, with disk as the subject, tooth as a within-disk factor, and material and layering condition as between-disk factors; within-disk effects were tested with the Greenhouse–Geisser correction. The significance level was set at α = 0.05. The methodological flow is shown in Figure 1.
3. Results
Material (F(4,60) = 1417.9; p < 0.001; ηp2 = 0.990), layering condition (F(2,60) = 403.0; p < 0.001; ηp2 = 0.931), and their interaction (F(8,60) = 82.8; p < 0.001; ηp2 = 0.917) significantly affected ΔEab (Table 3). Overall mean ΔEab was highest for Vitra (43.40 ± 3.65), followed by Transcend (40.17 ± 0.82), Omnichroma (37.74 ± 1.61), Zenchroma (35.88 ± 1.33), and A-UNO (32.73 ± 0.88), and all pairwise differences between materials were significant (p < 0.001). Mean ΔEab values for all material × condition combinations are given in Table 4, and the overall values for each material are shown in Figure 2.
Table 3.
Two-way ANOVA of disk-level ΔEab (n = 5 disks per group).
Table 4.
Mean ΔEab ± SD (95% CI) of each material under each layering condition (n = 5 disks per group).
Across all materials, ΔEab increased significantly from 0.5 mm of composite (36.61 ± 3.40) to 0.5 mm of composite over the blocker (37.50 ± 2.72) and to 1.0 mm of composite (39.86 ± 5.26) (all p < 0.001). The overall effect of each layering condition is shown in Figure 3.
Figure 2.
ΔEab of the five single-shade resin composites, pooled across layering conditions (n = 15 disks per material). Bars show means, error bars 95% CI, and dots individual disk values. Different letters indicate significant differences between materials (Bonferroni, p < 0.05). Because of the significant material × condition interaction, this pooled summary should be interpreted together with Table 4 and Figure 4.
Figure 3.
ΔEab under each layering condition, pooled across materials (n = 25 disks per condition). Bars show means, error bars 95% CI, and dots individual disk values. Different letters indicate significant differences between conditions (Bonferroni, p < 0.05). Because of the significant material × condition interaction, this pooled summary should be interpreted together with Table 4 and Figure 4.
With 0.5 mm of USRC, Vitra produced the highest ΔEab (41.11 ± 0.78), followed by Transcend (39.31 ± 0.11), Omnichroma (36.23 ± 0.23), Zenchroma (34.55 ± 0.45), and A-UNO (31.82 ± 0.27); all pairwise differences were significant (p < 0.001).
With 0.5 mm of USRC over a 0.5 mm blocker, Vitra (40.79 ± 0.73) and Transcend (40.10 ± 0.57) produced the highest ΔEab and did not differ significantly (p = 0.122). They were followed by Omnichroma (37.14 ± 0.27), Zenchroma (35.61 ± 0.35), and A-UNO (33.84 ± 0.08); all other pairwise differences were significant (p < 0.001).
With 1.0 mm of USRC, Vitra again produced the highest ΔEab (48.31 ± 0.35), followed by Transcend (41.10 ± 0.15), Omnichroma (39.85 ± 0.24), Zenchroma (37.48 ± 0.63), and A-UNO (32.53 ± 0.18); all pairwise differences were significant (p < 0.001).
The effect of layering condition differed among materials (Table 4). Compared with 0.5 mm of composite alone, 1.0 mm of composite increased ΔEab for all materials (p ≤ 0.027), and the blocker combination increased ΔEab for all materials except Vitra (p = 0.681). At equal total thickness (blocker + 0.5 mm vs. 1.0 mm), the blocker combination produced a greater ΔEab only for A-UNO, whereas 1.0 mm of composite produced a greater ΔEab for Zenchroma, Transcend, Vitra, and Omnichroma (all p ≤ 0.001). Mean ΔEab values for all material × condition combinations are shown in Figure 4.
Before staining, the five teeth had similar colors (L* = 88.43 ± 1.53, a* = 1.07 ± 1.41, b* = 25.90 ± 1.68), and staining shifted their color by 22.35–31.79 ΔE00 units (Table 2). No configuration restored the original color within the acceptability threshold: none of the 375 readings reached ΔE00 ≤ 1.8 (minimum 2.48). Layering condition (F(2,60) = 3119.3; ηp2 = 0.990), material (F(4,60) = 694.9; ηp2 = 0.979), and their interaction (F(8,60) = 172.8; ηp2 = 0.958) significantly affected ΔE00(original) (all p < 0.001; Table 5).
Table 5.
Color difference between the covered specimens and the original tooth color [ΔE00(original), mean ± SD with 95% CI; n = 5 disks per group], percentage of the staining-induced color difference corrected, and mean ΔL*, Δa*, and Δb* relative to the original color (covered − original).
For every material, 0.5 mm of composite over the blocker came closest to the original color (ΔE00 3.65–6.96; 75.3–87.1% of the staining-induced color difference corrected) and was significantly closer than both 0.5 mm and 1.0 mm of composite alone (all p < 0.001). Increasing composite thickness from 0.5 mm to 1.0 mm reduced ΔE00 for Zenchroma, A-UNO, Transcend, and Omnichroma, but increased it for Vitra (13.07 ± 0.15 vs. 14.03 ± 0.18; p < 0.001). A-UNO, which produced the smallest color change, was closest to the original color in all three conditions (ΔE00 3.65–8.03), whereas Vitra at 1.0 mm, which produced the largest color change, remained among the furthest from it (ΔE00 14.03 ± 0.18). Without the blocker, the covered specimens were darker (ΔL* −2.8 to −17.1) and less yellow (Δb* −0.4 to −21.5) than the original tooth; compared with 0.5 mm of composite alone, the blocker reduced both differences for every material.
Figure 4.
ΔEab of each material under each layering condition (n = 5 disks per group). Error bars show 95% CI. Brackets marked “ns” connect materials that did not differ significantly within a layering condition (Bonferroni, p > 0.05); all other pairs within each condition differed significantly.
In the repeated-measures model of the individual readings (Table 6), tooth accounted for 53.4% of the total sum of squares of ΔEab, reflecting differences in staining severity; its interactions with material and layering condition were significant but small (together 0.7% of the sum of squares), and the materials ranked identically on every tooth in every layering condition. For ΔE00(original), tooth accounted for 10.0%of the total sum of squares, compared with 51.4% for layering condition and 22.9% for material. Its interactions with material and layering condition were significant (p < 0.001 after Greenhouse–Geisser correction) but together accounted for 3.3%. The blocker combination was closest to the original color for every material on every tooth, and A-UNO was the closest material in 14 of the 15 tooth × condition combinations. Individual readings are provided in Supplementary Table S1.
Table 6.
Repeated-measures (split-plot) ANOVA of the 375 individual readings, with disk as the subject, tooth as a within-disk factor, and material and layering condition as between-disk factors.
4. Discussion
This study evaluated the color change produced by five single-shade resin composites over experimentally discolored tooth structure, and how restoration thickness and an underlying opaque blocker influenced the result. Material type and layering condition both affected the color change significantly, and the two factors interacted. The optical effect of a single-shade composite over a discolored substrate is therefore not a fixed property of the material; it also depends on how thickly the material is applied. The point matters clinically because these composites are increasingly chosen to simplify shade selection, yet their ability to hide intrinsic discoloration remains uncertain, particularly when a conservative preparation limits restoration thickness [8,21]. All three null hypotheses were therefore rejected.
Material type had the largest influence on ΔEab (ηp2 = 0.990), followed by layer-ing condition (ηp2 = 0.931) and their interaction (ηp2 = 0.917). These large effect sizes reflect the low variability among disks of the same group once readings were averaged across substrates. The significant interaction shows that extra thickness or a blocker did not affect every material to the same extent. Universal-shade composites should not, therefore, be treated as an optically uniform group. Differences in resin matrix, filler size and distribution, refractive index, translucency, pigment content, and structural-color technology all change how light travels through each material [22,23].
Vitra produced the greatest color change over the discolored substrate and A-UNO the smallest, and these differences were largest at 1.0 mm. At that thickness, Vitra reached a ΔEab of 48.31 and differed significantly from Transcend, whereas A-UNO reached only 32.53. Because ΔEab also reflects the intrinsic color of each material, these differences indicate how strongly each material alters the appearance of the substrate rather than providing a definitive ranking of masking ability. Although all five products are marketed as single-shade composites, they appear to adapt to the surrounding tooth color by different mechanisms. A material that depends mainly on high translucency and on light returned from the surrounding tooth may blend well over a normally colored substrate, but over a dark background it may let the substrate dominate the final color. A material that scatters more light, or is opaquer, limits the contribution of the underlying substrate [24].
Increasing thickness from 0.5 mm to 1.0 mm increased ΔEab significantly for every material, in line with earlier findings for opaque, conventional, and single-shade composites [25]. In a thicker layer, incident light travels through more matrix and filler and is scattered, absorbed, and internally reflected to a greater degree [26]. Less light therefore reaches the discolored substrate and returns to the observer [24]. The background contributes less to the perceived color, and the color of the restorative material itself dominates.
This dependence on thickness has implications for minimally invasive dentistry. Preserving sound tooth structure remains a primary aim, but a very conservative preparation may not leave enough room to conceal marked discoloration [27]. Different preparation depths were not tested here; the study compared only restorative layers of 0.5 mm and 1.0 mm, and the blocker configuration had the same total thickness as the 1.0 mm layer. In the present study, a 0.5 mm layer produced a smaller color change than a 1.0 mm layer for all materials, and the difference was largest for Vitra.
Placing a 0.5 mm blocker beneath 0.5 mm of composite increased ΔEab compared with 0.5 mm of composite alone for four of the five materials, which agrees with reports that opaque layers improve the masking of discolored backgrounds [28]. However, because the blocker combination is 1.0 mm thick in total, this comparison cannot isolate the optical contribution of the blocker itself. At equal total thickness, the outcome was material-dependent: the blocker combination produced a greater color change than 1.0 mm of composite only for A-UNO, whereas 1.0 mm of composite produced a greater change for Zenchroma, Transcend, Vitra, and Omnichroma. For Vitra, the blocker produced no significant change compared with 0.5 mm of composite alone.
The benefit of the blocker therefore depended on the overlying composite. With the blocker in place, Vitra and Transcend reached the highest ΔEab values, followed by Omnichroma, Zenchroma, and A-UNO. Together with the significant interaction, this indicates that the value of added thickness or an opaque layer depends on the optical properties of the overlying composite [29]. However, the magnitude of the color change does not show whether the final color approached that of the original tooth; this question is addressed below. A separate blocker also adds a clinical step and may make the technique more sensitive to error.
These results should be read considering how the color change was quantified. Discoloration was standardized by immersing bovine specimens in tea for 7 days, and color was measured instrumentally in CIELAB coordinates. In this design, ΔEab expresses the color change produced by placing the composite over the discolored substrate, so a larger value reflects a greater ability to alter the appearance of the background. However, ΔEab also reflects the intrinsic color of each material: two opaque materials of different color could produce different ΔEab values despite equally effective masking. Because a reference condition representing complete masking was not included, ΔEab should not be interpreted as a direct measure of masking ability. These values should not be compared with the perceptibility and acceptability thresholds used to judge color matching between a restoration and an adjacent tooth [20,30].
In the analysis introduced during revision, the original color of each tooth was used as a defined target. This addresses the limitation above in part, and it showed that the size of the color change does not indicate the quality of the final color. A-UNO produced the smallest color change but came closest to the original color in every condition, whereas Vitra at 1.0 mm produced the largest color change but remained among the furthest from it, because it almost eliminated the yellow component of the tooth (b* 4.4 vs. 25.9 originally). A large ΔEab can therefore reflect a shift in the substrate color in a direction other than towards the original tooth color, and it should not be read as better masking. No configuration restored the original color within the acceptability threshold, and the residual mismatch had a consistent direction: without the blocker, the covered specimens were too dark and lacked chroma. In this unbonded laboratory model, the configuration with a 0.5 mm blocker beneath 0.5 mm of composite showed the smallest difference from the original color for every material, on every tooth, together with smaller lightness and chroma deficits. One possible explanation is that the opaque layer reflects light before it reaches the dark substrate and contributes lightness and chroma that the translucent composites cannot provide on their own [24,25]. At the same total thickness, 1.0 mm of composite alone showed larger differences from the original color, and for Vitra a slightly larger difference than 0.5 mm. However, the blocker configuration contains an additional optical interface, and the coupling medium, positioning, contact pressure, and hydration were not standardized; part of this difference may therefore reflect the measurement set-up, which could bias the comparison in either direction. The blocker result should therefore be regarded as an observation in this unbonded model, not as evidence of an intrinsic advantage of the blocker or the materials, or of clinical benefit; confirming it would require controlled validation with standardized optical coupling, positioning, and contact pressure, bonded specimens, and visual assessment.
The practical relevance of these findings is limited. In this unbonded laboratory model, at the same total thickness of 1.0 mm, the configuration with a thin opaque blocker beneath 0.5 mm of composite showed the smallest difference from the original tooth color for all five materials; this observation is restricted to the materials, configurations, and tea-stained bovine substrates investigated, and it does not establish clinical benefit. The results do suggest that a single-shade composite should not be assumed to conceal underlying discoloration simply because it adapts well to normally colored tooth structure, and that even the configuration closest to the original color remained above the acceptability threshold. These conclusions apply within the single-shade technique: the study did not compare these options with conventional dentin–enamel layering, and the flat specimens represent the body of a facial restoration over discolored dentin rather than the incisal edge. Finally, color was measured immediately after specimen preparation, so these results do not address color stability or long-term esthetic performance [31]. Discoloration of the restoration, changes in translucency with aging, and degradation of the adhesive interface may alter the final appearance over time, and should be evaluated in aging studies and long-term clinical trials.
This study has several limitations. First, tea-stained bovine teeth were used. Bovine teeth are an accepted substitute for human teeth [16], but naturally discolored human teeth vary more in enamel and dentin thickness, chroma, translucency, and in the depth and distribution of the discoloration [32]. In addition, only five stained teeth were used as substrates. Although each disk was measured on every tooth, so that substrate variation affected all groups equally, tooth-to-tooth differences contributed substantially to the variance of individual readings and interacted significantly, though modestly, with material and layering condition, and the pH of the staining solution was not monitored. Second, a masking reference over standard white and black backgrounds could not be established because valid readings could not be obtained for all materials; the original tooth color was therefore used as a target, but complete masking itself was not measured, and ΔEab does not directly quantify masking ability. Third, the composites were tested as unbonded disks rather than as bonded restorations, so the adhesive interface, surrounding enamel, restoration contour, and intraoral lighting were not reproduced, and the additional optical interfaces of unbonded layers may have influenced the measurements. In addition, the coupling medium, specimen positioning, contact pressure, and hydration were not standardized during measurement. This is a principal limitation of the comparison between configurations, not only of reproducibility: air gaps and additional optical interfaces may have introduced systematic bias, particularly in the blocker condition, which contains an extra interface. Such bias could affect the comparison in either direction, and it is not excluded by the low variability among disks. Fourth, only two composite thicknesses and one blocker thickness were tested, and the same blocker (Omnichroma Blocker) was used under all five composites. The same five blocker disks were used under all five composites (fixed pairing by disk number), so comparisons between materials in the blocker condition are not fully independent. Fifth, conventional dentin/enamel layering was not included as a comparator, and flat disks cannot represent the different optical requirements of the tooth body and incisal edge; the study therefore cannot establish when a single-shade technique should replace a layered restoration. Finally, color was assessed only with an instrument and not visually by trained and untrained observers, although instrumental and visual assessments do not always agree [33]. In addition, the ΔE00 comparison with the original tooth color was introduced during peer review and should be regarded as exploratory. Future studies should standardize the measurement conditions (coupling medium, positioning, contact pressure, and hydration), include a reference masking condition, use naturally discolored human teeth, a wider range of thicknesses and blocker combinations, conventional layering comparators, and aging protocols, together with both instrumental and visual assessment. Clinical studies will ultimately be needed to establish whether these differences translate into visible esthetic improvement.
5. Conclusions
Within the limitations of this exploratory in vitro study, and for the five materials, three layering configurations, and five tea-stained bovine substrates investigated, the following conclusions were drawn:
- The color change produced by single-shade resin composites over discolored tooth structure depended on the material. Vitra produced the greatest change and A-UNO the smallest; single-shade composites should therefore not be regarded as optically equivalent.
- Increasing composite thickness from 0.5 mm to 1.0 mm significantly increased the color change for all materials, although the size of the increase differed between materials.
- The effect of a 0.5 mm opaque blocker beneath 0.5 mm of composite was material-dependent. At equal total thickness, it produced a greater color change than 1.0 mm of composite only for A-UNO, and a smaller change for Zenchroma, Transcend, Vitra, and Omnichroma.
- A larger color change did not indicate a closer match to the original tooth color. No configuration restored the original color within the acceptability threshold, but in this unbonded model the configuration with a 0.5 mm opaque blocker beneath 0.5 mm of composite showed the smallest difference from the original color for every material.
- These observations require controlled validation under standardized measurement conditions, with bonded specimens and visual assessment, before clinical recommendations can be made.
Studies on naturally discolored human teeth that combine instrumental and visual assessment, include a reference masking condition, use standardized measurement conditions, and evaluate long-term color stability are needed to confirm the clinical relevance of these findings.
Supplementary Materials
The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/dj14120780/s1, Table S1: Individual color readings with disk and tooth identifiers.
Author Contributions
Conceptualization, M.S.I. and V.P.; methodology, F.J. and S.A.; software, M.S.I.; validation, S.A.A.C., U.G. and N.T.H.; formal analysis, M.S.I., F.J. and S.A.; investigation, V.P.; resources, M.S.I.; data curation, F.J. and S.A.; writing—original draft preparation, M.S.I.; writing—review and editing, S.A.A.C., V.P., N.T.H., U.G. and M.M.R.; visualization, M.S.I., S.A.A.C., U.G. and M.M.R.; supervision, M.S.I., V.P., N.T.H., U.G. and M.M.R.; project administration, M.S.I.; funding acquisition, M.M.R. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
This in vitro study obtained ethical approval from the Research and Ethical Committee of RAK Medical and Health Sciences University, UAE, and (RAKCODS-REC-10-2024-25-F, approved 20 October 2024) prior to staring the experiment.
Informed Consent Statement
Not applicable.
Data Availability Statement
The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.
Acknowledgments
This study was supported by RAK College of Dental Sciences, RAK Medical and Health Sciences University.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Joiner, A.; Luo, W. Tooth Colour and Whiteness: A Review. J. Dent. 2017, 67, S3–S10. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Darabi, F.; Radafshar, G.; Tavangar, M.; Davaloo, R.; Khosravian, A.; Mirfarhadi, N. Translucency and Masking Ability of Various Composite Resins at Different Thicknesses. J. Dent. 2014, 15, 117–122. [Google Scholar]
- Jeong, J.; Kim, J.; Lee, J.; Kim, J.; Shin, J.; Han, M. Translucency and Masking Ability of Single-Shade Opaque Composite Resin Compared with Conventional Opaque Composite Resins According to Thickness. J. Korean Acad. Pediatr. Dent. 2025, 52, 312–321. [Google Scholar] [CrossRef] [Scilit]
- Ismail, E.H.; Paravina, R.D. Color Adjustment Potential of Resin Composites: Optical Illusion or Physical Reality, a Comprehensive Overview. J. Esthet. Restor. Dent. 2022, 34, 42–54. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Pereira Sanchez, N.; Powers, J.M.; Paravina, R.D. Instrumental and Visual Evaluation of the Color Adjustment Potential of Resin Composites. J. Esthet. Restor. Dent. 2019, 31, 465–470. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Islam, M.S.; Huda, N.; Mahendran, S.; Aryal Ac, S.; Nassar, M.; Rahman, M.M. The Blending Effect of Single-Shade Composite with Different Shades of Conventional Resin Composites—An In Vitro Study. Eur. J. Dent. 2023, 17, 342–348. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yamashita, A.; Kobayashi, S.; Furusawa, K.; Tichy, A.; Oguro, R.; Hosaka, K.; Shimada, Y.; Nakajima, M. Does the Thickness of Universal-Shade Composites Affect the Ability to Reflect the Color of Background Dentin? Dent. Mater. J. 2023, 42, 255–265. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kobayashi, S.; Nakajima, M.; Furusawa, K.; Tichy, A.; Hosaka, K.; Tagami, J. Color Adjustment Potential of Single-Shade Resin Composite to Various-Shade Human Teeth: Effect of Structural Color Phenomenon. Dent. Mater. J. 2021, 40, 1033–1040. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lucena, C.; Ruiz-López, J.; Pulgar, R.; Della Bona, A.; Pérez, M.M. Optical Behavior of One-Shaded Resin-Based Composites. Dent. Mater. 2021, 37, 840–848. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- de Abreu, J.L.B.; Sampaio, C.S.; Benalcázar Jalkh, E.B.; Hirata, R. Analysis of the Color Matching of Universal Resin Composites in Anterior Restorations. J. Esthet. Restor. Dent. 2021, 33, 269–276. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Iyer, R.S.; Babani, V.R.; Yaman, P.; Dennison, J. Color Match Using Instrumental and Visual Methods for Single, Group, and Multi-Shade Composite Resins. J. Esthet. Restor. Dent. 2021, 33, 394–400. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Chaple Gil, A.; Caviedes, R.; Bersezio, C.; Martín, J.; Fernández, E.; Angel, P. Color Matching and Stability of Single-Shade Chameleon Dental Composites: A Systematic Review. J. Esthet. Restor. Dent. 2025, 37, 1838–1847. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yılmaz, F.; Çinkılıç, M.T.; Çinkılıç, M.E. Evaluation of Color Matching of Single-Shade Resin Composites with Different Background Shades: An in Vitro Study. Sci. Rep. 2025, 15, 38163. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mohammadipour, H.S.; Yazdi, S.S.; Mashhad, M.J.M.; Babazadeh, S.; Shahri, A. Color Matching and Translucency of Single-Shade Resin Composites: Effects of Restoration Thickness, Background Shade, and Aging. BMC Oral Health 2025, 25, 616. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lee, S.; Lee, J.; Hong, M.; Kim, H. Influence of Use of Opaque Single-Shade Composite Resin and Residual Dentin Thickness on the Esthetic Performance of Single-Shade Composite Resin. J. Korean Acad. Pediatr. Dent. 2025, 52, 253–265. [Google Scholar] [CrossRef] [Scilit]
- Yassen, G.H.; Platt, J.A.; Hara, A.T. Bovine Teeth as Substitute for Human Teeth in Dental Research: A Review of Literature. J. Oral Sci. 2011, 53, 273–282. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Islam, M.S.; Aryal A C, S.; Padmanabhan, V.; Javed, F.; Ahmed, S.; Rahman, M.M. In Vitro Efficacy of Single-Shade Composite on Masking Discolored Tooth Structure. In Proceedings of the 1st International Online Conference on Dentistry, Online, 7–9 October 2026; MDPI: Basel, Switzerland, 2026; Available online: https://sciforum.net/event/IOCDT2026/home#hero (accessed on 21 November 2026).
- Islam, M.S.; Padmanabhan, V.; Abry, M.F.; Mousa Ahmed, K.M.; Smriti Aryal, A.C.; Rahman, M.M.; El Bahra, S. The Impact of Pre-Treatment with Desensitizing Agents on the Effectiveness of In-Office Bleaching: An In Vitro Study. Materials 2024, 17, 6097. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kyaw, K.Y.; Otsuki, M.; Segarra, M.S.; Tagami, J. Effect of Sodium Fluoride Pretreatment on the Efficacy of an In-Office Bleaching Agent: An in Vitro Study. Clin. Exp. Dent. Res. 2018, 4, 113–118. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Paravina, R.D.; Ghinea, R.; Herrera, L.J.; Bona, A.D.; Igiel, C.; Linninger, M.; Sakai, M.; Takahashi, H.; Tashkandi, E.; Del Mar Perez, M. Color Difference Thresholds in Dentistry. J. Esthet. Restor. Dent. 2015, 27, S1–S9. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ramos, A.B.; Barquete, C.G.; Pinhão, M.J.B. Can a Single-Shade Resin Composite Mask Darkened Teeth in a Veneer Restoration? A Clinical Case Report. Br. Dent. J. 2025, 239, 31–33. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yağcı, Ö.; Fidan, M. Influence of Thickness on the Translucency Parameter and Whiteness Index of Single-Shade Resin Composites. Oper. Dent. 2024, 49, 189–199. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Barbosa, L.d.N.; Leite, J.V.C.; Norat, R.F.; de Andrade, A.K.M.; Lima, R.B.W.; Pacheco, R.R. Single-Shade Resin Composites in Direct Restorations: A Scoping Review of Clinical and Laboratory Evidence. J. Dent. 2026, 176, 106999. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- An, J.-S.; Son, H.-H.; Qadeer, S.; Ju, S.-W.; Ahn, J.-S. The Influence of a Continuous Increase in Thickness of Opaque-Shade Composite Resin on Masking Ability and Translucency. Acta Odontol. Scand. 2013, 71, 120–129. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lehr, R.M.; Perez, B.G.; Gaidarji, B.; Dalmolin, A.; Durand, L.B. Masking Ability of the Combined Application of Opaquers and Resin Composite on Discolored Backgrounds. Oper. Dent. 2022, 47, 225–235. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Heyder, M.; Kranz, S.; Beck, J.; Wettemann, M.; Hennig, C.-L.; Schulze-Späte, U.; Sigusch, B.W.; Reise, M. Influence of Layer Thickness and Shade on the Transmission of Light through Contemporary Resin Composites. Materials 2024, 17, 1554. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Miotti, L.L.; Santos, I.S.; Nicoloso, G.F.; Pozzobon, R.T.; Susin, A.H.; Durand, L.B. The Use of Resin Composite Layering Technique to Mask Discolored Background: A CIELAB/CIEDE2000 Analysis. Oper. Dent. 2017, 42, 165–174. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Perez, B.G.; Miotti, L.L.; Susin, A.H.; Durand, L.B. The Use of Composite Layering Technique to Mask a Discolored Background: Color Analysis of Masking Ability After Aging-Part II. Oper. Dent. 2019, 44, 488–498. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Barros, M.S.; Silva, P.F.D.; Santana, M.L.C.; Bragança, R.M.F.; Faria-E-Silva, A.L. Effects of Surrounding and Underlying Shades on the Color Adjustment Potential of a Single-Shade Composite Used in a Thin Layer. Restor. Dent. Endod. 2023, 48, e7. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Paravina, R.D.; Pérez, M.M.; Ghinea, R. Acceptability and Perceptibility Thresholds in Dentistry: A Comprehensive Review of Clinical and Research Applications. J. Esthet. Restor. Dent. 2019, 31, 103–112. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Islam, M.S.; Smriti Aryal, A.C.; Elsayed, M.A.; Padmanabhan, V.; Sultana, M.; Hashim, N.T.; Guha, U.; Rahman, M.M. In Vitro Comparison of Mechanical and Esthetic Properties of Different Universal-Shade Resin Composites After Simulated Aging. Materials 2026, 19, 2778. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Aljanahi, M.; Alhussin, A.; Elbishari, H. Challenges Faced When Masking a Single Discoloured Tooth—Part 1: Aetiology and Non-Invasive Management. Br. Dent. J. 2025, 238, 919–924. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hein, S.; Saleh, O.; Li, C.; Nold, J.; Westland, S. Bridging Instrumental and Visual Perception with Improved Color Difference Equations: A Multi-Center Study. Dent. Mater. 2024, 40, 1497–1506. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.