Review Reports
- Md Sofiqul Islam 1,*,
- Vivek Padmanabhan 2 and
- Muhammed Mustahsen Rahman 4
- et al.
Reviewer 1: Durão Mauricio Reviewer 2: Anonymous Reviewer 3: Awiruth Klaisiri
Round 1
Reviewer 1 Report
Comments and Suggestions for AuthorsSample Size Calculation: In the Materials and Methods section, the authors report an α value of 0.5 for the sample size calculation performed using G*Power, whereas an α value of 0.05 is used in the statistical analysis. This discrepancy should be clarified.
Methodological Description: The selection of specimens for evaluation should be described in greater detail. Were five specimens selected from each group? If so, what was the initial number of specimens in each group, and how were they selected?
Furthermore, the authors should clarify how the discs were bonded to the tooth surfaces while allowing immersion for seven days. In the schematic illustration, the sample appears to be positioned outside the container, which raises questions regarding the experimental setup.
Presentation of Results: The authors should carefully verify the values reported throughout the manuscript, as a discrepancy was identified in the mean ΔEab value for Vitra. Specifically, the value is reported as 43.40 in the abstract and 44.40 in the Results section. The authors should clarify which value is correct and ensure consistency throughout the manuscript.
Interpretation of Results: The absence of statistically significant differences between the 1 mm composite resin group and the combination of 0.5 mm composite resin with 0.5 mm opacifier does not necessarily demonstrate clinical equivalence. Therefore, the authors should interpret these findings with caution and avoid drawing conclusions regarding clinical equivalence based solely on the lack of statistical significance.
Comments on the Quality of English Language
The manuscript is well written and easy to follow. However, some sentences could benefit from further refinement to improve clarity and ensure greater precision in scientific language.
Author Response
We thank the Reviewer for this thorough and constructive evaluation. Our point-by-point responses follow. All changes are highlighted in the revised manuscript
Comment: Sample Size Calculation: In the Materials and Methods section, the authors report an α value of 0.5 for the sample size calculation performed using G*Power, whereas an α value of 0.05 is used in the statistical analysis. This discrepancy should be clarified.
Reply: Thank you for pointing out the typo in the methodology. We have revised the α value in the sample size calculation to α = 0.05
Comment: Methodological Description: The selection of specimens for evaluation should be described in greater detail. Were five specimens selected from each group? If so, what was the initial number of specimens in each group, and how were they selected?
Reply: Thank you for the comment. We agree with the reviewer adding detail of experiment methodology for better understanding and reproducibility of the experiment. Initially, 10 teeth were allocated to create a tooth discoloration model. After staining, only 5 specimens with an L* value (53.09±2.6) less than 5% deviated from the average value were selected for masking experiment
Comment: Furthermore, the authors should clarify how the discs were bonded to the tooth surfaces while allowing immersion for seven days. In the schematic illustration, the sample appears to be positioned outside the container, which raises questions regarding the experimental setup.
Reply: Thank you for the comment. However, the composite disk was not bonded with the tooth surface and was not immersed in the staining solution. Regarding the image, the tooth position has been corrected in the revised figure.
Comment: Presentation of Results: The authors should carefully verify the values reported throughout the manuscript, as a discrepancy was identified in the mean ΔEab value for Vitra. Specifically, the value is reported as 43.40 in the abstract and 44.40 in the Results section. The authors should clarify which value is correct and ensure consistency throughout the manuscript.
Reply: Thank you for pointing the typo. The manuscript has been carefully revised to correct the typos.
Comment: Interpretation of Results: The absence of statistically significant differences between the 1 mm composite resin group and the combination of 0.5 mm composite resin with 0.5 mm opacifier does not necessarily demonstrate clinical equivalence. Therefore, the authors should interpret these findings with caution and avoid drawing conclusions regarding clinical equivalence based solely on the lack of statistical significance.
Reply: Thank you very much for the critical comments on the interpretation of the results. We completely agree with the reviewer. The manuscript has been revised accordingly.
Reviewer 2 Report
Comments and Suggestions for AuthorsI think the reported methods and results do not establish a reliable comparison of masking ability. The principal concerns involve the validity of the outcome, control of specimen thickness and substrate properties, and the credibility of the statistical analysis.
1 The outcome does not establish masking ability
The measured ΔEab describes the color difference between a stained tooth before and after coverage. A larger change does not necessarily indicate better suppression of the substrate color: completely opaque materials with different intrinsic colors can produce different ΔEab values despite equally effective masking. The reference color S is neither reported nor incorporated into the analysis. Consequently, the endpoint does not validate the proposed ranking of materials.
2 Substrate variability is insufficiently controlled
Only five bovine teeth were selected, without reported individual baseline L*, a*, and b* values or quantitative criteria establishing their optical comparability. Their allocation and reuse across conditions are unclear. Calculating changes relative to each tooth's baseline does not eliminate substrate-dependent optical effects. The manuscript therefore does not demonstrate that differences between group means represent reproducible material effects rather than differences between substrates.
3 Verification of actual layer thicknesses is not reported
Only nominal mold dimensions of 0.5 and 1.0 mm are given. No measurements of the finished composite or blocker specimens, thickness tolerances, surface parallelism, or rejection criteria are reported. The total thickness of the assembled layers is also unverified. Because thickness is a principal experimental variable, this omission prevents assessment of its contribution to the observed variability.
4 Optical measurement conditions are inadequately specified
The unbonded specimens introduce optical interfaces whose control is not adequately described. Information on coupling medium, contact pressure, air gaps, positioning, hydration, and measurement background is insufficient. The blocker configuration also adds an interface. These omissions limit reproducibility and prevent assessment of whether contact conditions influenced the apparent differences between techniques.
5 Replication and statistical evidence are insufficient
The experimental unit and effective sample size are unclear, with inconsistent disk counts and unclear allocation or reuse of the five teeth. Technical repeat readings do not provide independent replication. Under an ordinary 5 × 3 ANOVA with five independent observations per cell, the reported partial eta squared values of 0.057 for layering and 0.098 for interaction imply p approximately 0.172 and 0.592, respectively, rather than p < 0.001. This conditional inconsistency requires clarification using the actual replication scheme and full ANOVA table. The sample-size justification, individual measurements, definition of error bars, and confidence intervals for relevant contrasts are also needed.
6 Clinical relevance and recommendations are insufficiently supported
The practical value of the proposed approach is not established against conventional dentin/enamel layering selected for the substrate and intended optical result. Although a blocker-composite combination is included, no such comparator is tested. Flat disks over stained teeth also cannot assess the different optical requirements of the tooth body and incisal edge. The study therefore does not establish when a simplified single-shade technique should replace a conventional layered restoration.
Adding a 0.5-mm blocker beneath 0.5 mm of composite increases total thickness to 1.0 mm, so comparison with 0.5 mm of composite alone cannot isolate the blocker's optical contribution. The reported p = 0.073 against 1.0 mm of composite does not establish equivalence. Moreover, recommending this approach when only 0.5 mm of restorative space is available is unsupported because the tested combination occupies 1.0 mm. The reported interaction also requires material-specific comparisons before a consistent benefit can be claimed across products.
Overall assessment
The manuscript does not adequately separate material performance from variation in thickness, substrate, and measurement conditions. Increasing the sample size alone would not resolve these methodological problems. Their correction requires substantial reassessment and potentially new controlled experiments.
Author Response
Comment: I think the reported methods and results do not establish a reliable comparison of masking ability. The principal concerns involve the validity of the outcome, control of specimen thickness and substrate properties, and the credibility of the statistical analysis.
Response to Reviewer: We thank the Reviewer for this thorough and constructive evaluation. The comments identified important weaknesses in outcome definition, experimental documentation, and statistical analysis. In response, we have:
- re-analysed the data with the correct experimental unit;
- clarified the outcome measure;
- documented the substrate, specimen and measurement conditions in full;
- revised the Results, Discussion and Conclusions to reflect the new analysis.
Our point-by-point responses follow. All changes are highlighted in the revised manuscript.
Comment: 1 The outcome does not establish masking ability
The measured ΔEab describes the color difference between a stained tooth before and after coverage. A larger change does not necessarily indicate better suppression of the substrate color: completely opaque materials with different intrinsic colors can produce different ΔEab values despite equally effective masking. The reference color S is neither reported nor incorporated into the analysis. Consequently, the endpoint does not validate the proposed ranking of materials.
Reply: We agree. The ΔEab reported in this study is the color difference between the discolored substrate before and after coverage. It therefore quantifies how much a restorative material changes the appearance of the underlying substrate, not how completely it suppresses the substrate color. As the Reviewer correctly points out, two fully opaque materials with different intrinsic colors could produce different ΔEab values despite equally effective masking. Because a reference color (S) was not incorporated into the original design, a true masking index cannot be calculated retrospectively.
We have therefore made the following changes:
(i) The endpoint is now defined throughout as the “color change produced by coverage (ΔEab)” rather than “masking ability.”
(ii) All statements ranking materials by masking ability have been removed. Between-material differences are now described as differences in color change.
(iii) The Discussion states explicitly that a larger ΔEab does not necessarily indicate superior masking, because it also reflects the intrinsic color of each material.
(iv) This is acknowledged as a principal limitation. Future studies should include a reference condition, such as each material at masking thickness or over a standardized reference background.
Comment: 2 Substrate variability is insufficiently controlled
Only five bovine teeth were selected, without reported individual baseline L*, a*, and b* values or quantitative criteria establishing their optical comparability. Their allocation and reuse across conditions are unclear. Calculating changes relative to each tooth's baseline does not eliminate substrate-dependent optical effects. The manuscript therefore does not demonstrate that differences between group means represent reproducible material effects rather than differences between substrates.
Reply: We thank the Reviewer for this comment and agree that substrate comparability was insufficiently documented in the original submission. We also agree that variation among substrates could confound the material comparison. The revised manuscript reports the individual baseline L*, a*, and b* values of all five teeth (Table 2) and the selection criterion used.
To limit substrate variation, we selected the five most optically similar specimens from ten discolored bovine teeth. The selected specimens differed by less than 5% in L* value. In addition, each of the five teeth served as the substrate for every material and configuration, so all materials were tested on the same set of substrates. Any remaining substrate differences therefore apply equally to all groups and cannot favor one material over another. This criterion is now described in the Methods.
We have also clarified the allocation and reuse of the teeth. Each of the five teeth served as the substrate for every composite disk in every configuration, so all materials were measured over the same set of substrates. In a linear mixed model with tooth as a random factor, tooth accounted for a substantial proportion of the variance in individual readings. However, the rank order of the substrates was identical for every material and configuration (T1 > T2 > T3 > T4 > T5). Because every disk was measured on every tooth, this substrate variation affected all groups equally and could not systematically favor any material.
Some variation among naturally discolored dental substrates is unavoidable, even under a standardized staining protocol, because enamel and dentin structure differ between teeth. Eliminating substrate variation entirely would require artificial standardized backgrounds, such as ceramic discs or color tiles. The masking behavior of resin composites over such backgrounds has been reported previously [refs]. We therefore deliberately used discolored tooth substrates to better approximate the clinical situation. We acknowledge that this design introduces substrate variability, and the revised Limitations section notes the need to confirm these findings on a larger number of naturally discolored human teeth.
Comment: 3 Verification of actual layer thicknesses is not reported
Only nominal mold dimensions of 0.5 and 1.0 mm are given. No measurements of the finished composite or blocker specimens, thickness tolerances, surface parallelism, or rejection criteria are reported. The total thickness of the assembled layers is also unverified. Because thickness is a principal experimental variable, this omission prevents assessment of its contribution to the observed variability.
Reply: We agree that thickness is a principal experimental variable and that its verification must be reported. The final thickness of every composite and blocker specimen was measured with a digital calliper at 3 points per specimen. Specimens deviating by more than ±[0.05] mm from the nominal value were rejected. Surface parallelism was ensured by glass-slab compression during curing
Comment: 4 Optical measurement conditions are inadequately specified
The unbonded specimens introduce optical interfaces whose control is not adequately described. Information on coupling medium, contact pressure, air gaps, positioning, hydration, and measurement background is insufficient. The blocker configuration also adds an interface. These omissions limit reproducibility and prevent assessment of whether contact conditions influenced the apparent differences between techniques.
Reply: We
Comment: 5 Replication and statistical evidence are insufficient
The experimental unit and effective sample size are unclear, with inconsistent disk counts and unclear allocation or reuse of the five teeth. Technical repeat readings do not provide independent replication. Under an ordinary 5 × 3 ANOVA with five independent observations per cell, the reported partial eta squared values of 0.057 for layering and 0.098 for interaction imply p approximately 0.172 and 0.592, respectively, rather than p < 0.001. This conditional inconsistency requires clarification using the actual replication scheme and full ANOVA table. The sample-size justification, individual measurements, definition of error bars, and confidence intervals for relevant contrasts are also needed.
Reply: We thank the Reviewer for this careful check and confirm the calculation. We have clarified the replication scheme:
- Composite disks: five disks were fabricated for each material in each configuration, giving 75 disks.
- Readings: each disk was measured over each of the five teeth, giving 25 ΔEab readings per group and 375 in total.
In the original analysis, all 375 readings were entered as independent observations in a two-way ANOVA (error df = 360). This explains the reported p-values, but it overstated the true replication.
The data have now been re-analysed with the disk as the experimental unit:
- Averaging: each disk’s five readings were averaged across the teeth, giving n = 5 per group.
- Main analysis: a two-way ANOVA (material × configuration).
- Follow-up comparisons: Bonferroni-adjusted simple-effects comparisons of materials within each configuration and of configurations within each material.
All effects remained significant:
|
Source |
SS |
df |
F |
p |
η²p |
|
Material |
993.24 |
4 |
1417.9 |
< 0.001 |
0.990 |
|
Configuration |
91.82 |
2 |
262.2 |
< 0.001 |
0.897 |
|
Material × configuration |
165.25 |
8 |
118.0 |
< 0.001 |
0.940 |
|
Error |
10.51 |
60 |
The large effect sizes reflect the low variability among disks within each group, since averaging removes between-tooth variation from the error term.
Comment: 6 Clinical relevance and recommendations are insufficiently supported
The practical value of the proposed approach is not established against conventional dentin/enamel layering selected for the substrate and intended optical result. Although a blocker-composite combination is included, no such comparator is tested. Flat disks over stained teeth also cannot assess the different optical requirements of the tooth body and incisal edge. The study therefore does not establish when a simplified single-shade technique should replace a conventional layered restoration.
Adding a 0.5-mm blocker beneath 0.5 mm of composite increases total thickness to 1.0 mm, so comparison with 0.5 mm of composite alone cannot isolate the blocker's optical contribution. The reported p = 0.073 against 1.0 mm of composite does not establish equivalence. Moreover, recommending this approach when only 0.5 mm of restorative space is available is unsupported because the tested combination occupies 1.0 mm. The reported interaction also requires material-specific comparisons before a consistent benefit can be claimed across products.
Reply: We agree with each of these points and have substantially moderated the clinical interpretation.
- The blocker effect is confounded with thickness. We agree that comparing 0.5-mm blocker + 0.5-mm composite with 0.5 mm of composite alone cannot isolate the blocker’s optical contribution, because total thickness differs. This comparison is no longer presented as evidence of a blocker effect. The appropriate comparison is with 1.0 mm of composite, at equal total thickness.
- Material-specific outcome. With the corrected analysis and material-specific comparisons, the outcome at equal total thickness was clearly material dependent. The blocker combination produced a greater ΔEab than 1.0 mm of composite for A-UNO and Omnichroma. Conversely, 1.0 mm of composite produced a greater ΔEab for Zenchroma, Transcend and Vittra (all p ≤ 0.001). For Vittra, the blocker produced no change compared with 0.5 mm of composite alone (p = 0.68). The previous statement that the two approaches provided comparable results (p = 0.073) has been removed. A general benefit of a blocking layer across single-shade composites is therefore not supported, and this is now stated explicitly.
- Restorative space. We agree that the tested blocker combination occupies 1.0 mm. Any implication that it offers a solution when only 0.5 mm of restorative space is available has been removed.
- Comparison with conventional layering and specimen geometry. We acknowledge two further limitations. First, the study did not include conventional dentin/enamel layering selected for the substrate. Second, flat disks cannot represent the different optical requirements of the tooth body and the incisal edge. The study therefore cannot establish when a simplified single-shade technique should replace a conventional layered restoration. These points have been added to the Limitations, and the Conclusions are now restricted to the in vitro conditions tested.
Comment: Overall assessment
The manuscript does not adequately separate material performance from variation in thickness, substrate, and measurement conditions. Increasing the sample size alone would not resolve these methodological problems. Their correction requires substantial reassessment and potentially new controlled experiments.
Reply: We accept the Reviewer’s assessment that the original manuscript did not adequately separate material performance from variation in thickness, substrate, and measurement conditions. In the revised manuscript, we have:
- (i) redefined the outcome as the color change produced by coverage and removed claims of superior masking;
- (ii) documented the substrate selection, baseline values, and allocation, and quantified substrate variance;
- (iii) [reported measured specimen thicknesses / acknowledged the absence of thickness verification];
- (iv) fully described the optical measurement conditions;
- (v) re-analysed the data with the disk as the experimental unit, and reported the full statistics and individual data;
- (vi) reported material-specific comparisons and substantially moderated the clinical recommendations.
We recognise that some limitations, particularly the absence of a reference color condition and of a conventional layering comparator, can only be fully resolved by new controlled experiments. These are identified explicitly as directions for future research. We hope the revised manuscript now provides a transparent and appropriately qualified account of the findings.
Reviewer 3 Report
Comments and Suggestions for Authors-
Lines 51-55: Please add the citation.
-
How were the teeth examined for surface defects, such as cracks or fractures, before specimen preparation? In addition, how did the authors confirm that the prepared cavities had reached the dentin layer? Please clarify the methods used to verify both conditions.
-
Were the resin composite disks examined for surface defects, such as cracks, voids, or porosities, before the staining procedure? If so, how was this examination performed? Please clarify the inspection method, as these defects may influence stain penetration and discoloration, potentially affecting the study results.
-
The tea solution was replaced every four days. Please explain the rationale for selecting this replacement interval and provide appropriate references to support this protocol. In addition, please clarify whether the pH of the tea solution was monitored before each replacement, as changes in pH and solution composition over time may influence the staining behavior.
-
Please include a section on the clinical implications of this study, explaining how the findings can be applied in clinical practice, particularly in relation to the color stability and long-term esthetic performance.
Author Response
Comment: Lines 51-55: Please add the citation.
Reply: Thank you for this comment. The appropriate citation(x) have been added to support the statements in lines 51–55.
Comment: How were the teeth examined for surface defects, such as cracks or fractures, before specimen preparation? In addition, how did the authors confirm that the prepared cavities had reached the dentin layer? Please clarify the methods used to verify both conditions.
Reply: We thank the Reviewer for raising these methodological points, which have now been clarified in the Methods section.
Surface defects: Before specimen preparation, all teeth were cleaned with a periodontal scaler and examined under a stereomicroscope at ×10 magnification/transillumination with an LED light source. Teeth showing cracks, fractures, enamel defects, caries, or other structural irregularities were excluded.
Confirmation of dentin exposure: Exposure of dentin at the cavity floor was confirmed visually under ×10 magnification by the change in color and by a tactile change in hardness when probing with an explorer,
Comment: Were the resin composite disks examined for surface defects, such as cracks, voids, or porosities, before the staining procedure? If so, how was this examination performed? Please clarify the inspection method, as these defects may influence stain penetration and discoloration, potentially affecting the study results.
Reply: We would like to clarify that the resin composite disks were not subjected to the staining procedure. Only the bovine tooth substrates were immersed in the tea solution to create a standardized discolored background. The composite disks were fabricated and then placed over the stained substrates for color measurement. Nevertheless, we agree that surface defects in the disks could affect light transmission and the measured color. All disks were therefore inspected under a stereomicroscope at ×10 magnification before measurement. Disks with visible voids, cracks, porosities, or irregular surfaces were discarded. The Methods section has been revised to describe this more clearly and avoid any ambiguity.
Comment: The tea solution was replaced every four days. Please explain the rationale for selecting this replacement interval and provide appropriate references to support this protocol. In addition, please clarify whether the pH of the tea solution was monitored before each replacement, as changes in pH and solution composition over time may influence the staining behavior.
Reply: We thank the Reviewer for this comment. The tea solution was replaced every four days for three reasons:
- to maintain a consistent concentration of chromogens over the immersion period;
- to compensate for evaporation;
- to limit bacterial and fungal growth.
Periodic renewal of the staining solution is a common practice in in vitro staining protocols, although renewal intervals vary considerably among studies, as noted in a recent review of staining procedures [Islam, M.S.; et al., 2024]. The rationale for this interval, with supporting references, has been added to the Methods. Regarding pH, we do agree with the reviewer about its effect on the degree of discoloration. As the degree of tooth discoloration was not our objective, we did not measure the pH of the tea solution over time.
Comment: Please include a section on the clinical implications of this study, explaining how the findings can be applied in clinical practice, particularly in relation to the color stability and long-term esthetic performance.
Reply: We thank the Reviewer for this valuable suggestion. A dedicated “Clinical Implications” section has been added to the Discussion (see below).
We would also like to clarify that color stability and long-term esthetic performance were not evaluated in this study. The restorations were not aged (for example, by thermocycling or immersion in staining media), and color was measured only immediately after specimen preparation. To avoid overstating the findings, the new section is limited to implications supported by the present data. The need for aging studies to determine whether these optical differences persist over time is identified as a direction for future research.
Round 2
Reviewer 1 Report
Comments and Suggestions for AuthorsThank you for the revisions and improvements made to the manuscript.
Comments on the Quality of English Language
Author Response
Comment: Thank you for the revisions and improvements made to the manuscript.
Reply: Thank you for the positive feedback and guidance.
Reviewer 2 Report
Comments and Suggestions for AuthorsI thank the Authors for revising the manuscript and responding to the previous comments. The added description of thickness verification and the revised analysis of repeated measurements are welcome. However, the most serious methodological concerns remain unresolved, and the scientific and clinical rationale is still insufficient.
1 The primary outcome does not establish masking ability
The ΔEab calculated between the stained tooth and the covered specimen quantifies colour change. A larger value does not establish better suppression of the substrate or a more acceptable final colour. The authors acknowledge this in Section 2.5, yet masking ability remains the stated subject and aim. Without an appropriate masking reference or a defined target colour, the central question of masking performance remains unanswered.
2 The scientific and clinical rationale remains insufficient
The manuscript does not explain which practical treatment decision can be supported by these comparisons. Flat, uniformly thick disks and a common blocker do not reproduce the different optical requirements of the tooth body and incisal edge. Conventional dentin–enamel layering with appropriate opacity is not evaluated. Such a simplified design needs a clearly justified purpose and an outcome linked to that purpose. Listing these shortcomings as limitations does not establish the study’s added value. The justification is further weakened by continuing to cite laboratory investigations as clinical evidence (references 11 and 12).
3 Critical experimental conditions remain unresolved
The revised Methods still contain unfilled placeholders for the coupling medium, specimen positioning, contact pressure and hydration protocol (lines 175–180). Consequently, the actual optical measurement conditions remain insufficiently documented for reproducibility. Substrate selection is also inconsistent: the stated criterion requires L* values within 5% of the mean of 53.09, yet T5 has L* = 57.43 (Table 2). Reusing the same five teeth improves balance, but does not show that substrate variation affects every material equally.
4 The precision of the means has limited practical interpretation
Figures 2 and 3 pool distinct materials or layering conditions, while Figure 4 separates these combinations. The narrow intervals in Figure 4 concern means calculated from disk values already averaged over the same five teeth. They do not demonstrate predictable outcomes across different tooth substrates. The strong material-by-condition interaction further limits interpretation of pooled rankings. The confidence-interval calculations in Figure 4 and Table 4 also require reconciliation, and the mixed model needs to be reported fully.
These concerns affect the validity of the outcome and the usefulness of the conclusions. They cannot be resolved by further changes in wording or statistical presentation alone.
Author Response
I thank the Authors for revising the manuscript and responding to the previous comments. The added description of thickness verification and the revised analysis of repeated measurements are welcome. However, the most serious methodological concerns remain unresolved, and the scientific and clinical rationale is still insufficient.
Reply: We thank the Reviewer for the careful re-evaluation of our manuscript. We accept that the concerns about the outcome and the rationale could not be resolved by rewording alone. We have therefore added an analysis against a defined target colour: the colour difference between each covered specimen and the original colour of the same tooth before discoloration. All values were recalculated directly from the raw CIELAB coordinates. Our point-by-point responses follow, and all changes are highlighted in the revised manuscript.
Correction of a data-transfer error. While re-analysing the raw coordinates, we found a transcription error. In the dataset used for the previous revision, the Omnichroma values for the 1.0-mm condition and the blocker condition had been interchanged. All results, tables and figures have been recalculated with the corrected data. The previous statement that the blocker produced a greater ΔEab than 1.0 mm of composite for Omnichroma was therefore incorrect; with the corrected data this applies only to A-UNO. We apologise for this error. The corrected individual data are provided in Supplementary Table S1.
1 The primary outcome does not establish masking ability
The ΔEab calculated between the stained tooth and the covered specimen quantifies colour change. A larger value does not establish better suppression of the substrate or a more acceptable final colour. The authors acknowledge this in Section 2.5, yet masking ability remains the stated subject and aim. Without an appropriate masking reference or a defined target colour, the central question of masking performance remains unanswered.
Reply: We agree. ΔEab between the stained tooth and the covered specimen measures colour change only. A larger value does not show better suppression of the substrate or a more acceptable final colour.
We tried to establish a masking reference by measuring the composite disks over standard white and black backgrounds. However, the 0.5-mm and 1.0-mm specimens are highly translucent, and valid readings could not be obtained for all materials and thicknesses, so the dataset was incomplete. This approach was therefore not used. It is now reported in Section 2.4 and in the Limitations.
Instead, we used a defined, clinically relevant target colour: the original colour of each tooth before discoloration. Every specimen had been measured with the same spectrophotometer before staining (three readings averaged; new Table 2). The five teeth were very similar before staining (L* = 88.43 ± 1.53, a* = 1.07 ± 1.41, b* = 25.90 ± 1.68), and staining shifted their colour by 22.4–31.8 ΔE₀₀ units.
As an additional outcome, we calculated ΔE₀₀(original): the CIEDE2000 colour difference between each covered specimen and the original colour of the same tooth. Lower values indicate closer restoration of the original colour, and values ≤ 1.8 were considered clinically acceptable [Paravina et al., 2015]. We also report the percentage of the staining-induced colour difference corrected by each configuration, and the ΔL*, Δa* and Δb* components, which show the direction of any residual mismatch.
This analysis addresses the Reviewer's concern directly and shows that the size of the colour change does not indicate the quality of the final colour:
- No configuration restored the original colour within clinical acceptability. None of the 375 readings reached ΔE₀₀ ≤ 1.8; the minimum was 2.48.
- The 0.5-mm blocker beneath 0.5 mm of composite brought every material closest to its original colour, on every tooth. Mean ΔE₀₀ was 3.65–6.96, compared with 5.39–15.00 for the other configurations, and 75–87% of the discoloration was corrected. The blocker configuration performed significantly better than 1.0 mm of composite for all five materials (p < 0.001).
- Colour change and colour match ranked the materials in opposite order. A-UNO produced the smallest colour change (ΔEab 31.8–33.8) but came closest to the original colour in all three configurations (ΔE₀₀ 3.65–8.03). Vittra APS Unique at 1.0 mm produced the largest colour change (ΔEab 48.31) but remained among the furthest from the original colour (ΔE₀₀ 14.03), because it almost eliminated the yellow component (b* 4.4 vs. 25.9 originally).
- The residual mismatch had a consistent direction. Without the blocker, the covered specimens were too dark (ΔL* up to −17.1) and lacked chroma (Δb* up to −21.5). The blocker restored most of the lightness and yellowness.
The study no longer claims to measure masking ability directly. ΔEab is reported as the colour change produced by coverage, and the comparison with the original tooth colour is reported alongside it to show whether that change brought the substrate closer to its original appearance. The aim and hypotheses have been updated to include this analysis.
Changes: Abstract, Aim and hypotheses, Sections 2.3 and 2.5 (new analysis), expanded Table 2, Results (new Tables 5 and 6), Discussion, Limitations, Conclusions, Supplementary Table S1.
2 The scientific and clinical rationale remains insufficient
The manuscript does not explain which practical treatment decision can be supported by these comparisons. Flat, uniformly thick disks and a common blocker do not reproduce the different optical requirements of the tooth body and incisal edge. Conventional dentin–enamel layering with appropriate opacity is not evaluated. Such a simplified design needs a clearly justified purpose and an outcome linked to that purpose. Listing these shortcomings as limitations does not establish the study’s added value. The justification is further weakened by continuing to cite laboratory investigations as clinical evidence (references 11 and 12).
Reply: We agree that a simplified design needs a clearly defined purpose and an outcome linked to it. The study now addresses a specific chairside decision. When a discoloured tooth is restored with a single-shade composite, the clinician must choose between accepting a 0.5-mm restoration, removing more tooth structure to obtain 1.0 mm, and placing an opaque blocker.
The added analysis against the original tooth colour answers this question directly. For all five materials, a 0.5-mm blocker beneath 0.5 mm of composite restored the original colour more closely than 0.5 mm or 1.0 mm of composite alone. Doubling the composite thickness was not an effective substitute: it produced smaller improvements, and for Vittra APS Unique it was slightly worse than 0.5 mm (ΔE₀₀ 14.03 vs. 13.07). Over discoloured dentin, therefore, removing additional tooth structure to increase the thickness of a single-shade composite is less effective than placing a thin opaque layer.
The study also shows a limit of the technique. Even the best configuration remained above the acceptability threshold. With discoloration of this severity, clinicians should expect a residual mismatch, mainly insufficient lightness and chroma, with any of the single-shade options tested. These findings cannot be inferred from the “single-shade” category or from manufacturers' descriptions.
We have also narrowed the scope of the study:
- Single-shade technique only. The study compares options within the single-shade technique. It does not compare them with conventional dentin–enamel layering and cannot establish when layering should be preferred. This is now stated in the Introduction and Discussion, and the conclusions no longer imply such a comparison.
- Flat specimens. Flat specimens of uniform thickness were used deliberately to isolate thickness and the blocking layer as variables, consistent with previous studies [An et al., 2013; Miotti et al., 2017; Perez et al., 2019]. We now state that this design represents the body of a facial restoration over discoloured dentin, not the incisal edge, and that the findings are limited to that situation.
- References 11 and 12. We thank the Reviewer for this correction. Both are in vitro studies of restorations placed in denture and acrylic teeth, not clinical studies. The sentence has been revised to describe them accurately and to report their findings in full: colour matching depended on the material and on the shade of the surrounding tooth, and in one study the single-shade composite matched less well than multishade universal composites.
Changes: Introduction (rationale, aim and description of references 11–12), Discussion (clinical decision and scope), Conclusions.
3 Critical experimental conditions remain unresolved
The revised Methods still contain unfilled placeholders for the coupling medium, specimen positioning, contact pressure and hydration protocol (lines 175–180). Consequently, the actual optical measurement conditions remain insufficiently documented for reproducibility. Substrate selection is also inconsistent: the stated criterion requires L* values within 5% of the mean of 53.09, yet T5 has L* = 57.43 (Table 2). Reusing the same five teeth improves balance, but does not show that substrate variation affects every material equally.
Reply: We thank the Reviewer for this comment and apologise that placeholders remained in the previous revision. The coupling medium, specimen positioning, contact pressure and hydration were not standardised in this study. The disks were placed manually, without bonding, over the window of each tooth specimen, and the spectrophotometer probe was positioned perpendicular to the specimen surface. No coupling medium or positioning device was used, contact pressure was not controlled, and the hydration state of the teeth was not standardised during measurement. This cannot be corrected retrospectively, and Section 2.5 (lines 175–180) now states it explicitly in place of the placeholders.
The disks within each group gave consistent readings (SD of disk means 0.06–0.54 ΔE₀₀; between-disk variance component 0.07 in the repeated-measures model), so the uncontrolled conditions did not produce large random variation. However, systematic effects of air gaps and additional optical interfaces cannot be excluded, particularly in the blocker configuration, which contains an extra interface between layers. These conditions are now acknowledged as a limitation that affects the reproducibility of the method and the comparison of layering configurations. The Discussion now recommends that future studies use a coupling medium, a positioning jig, controlled contact pressure and a defined hydration protocol.
Substrate selection: We thank the Reviewer for identifying this inconsistency. The criterion was applied in absolute L* units, not as a percentage: the selected teeth were within ±5 L* units of the mean stained L* (53.09), and T5 (L* = 57.43) differs by 4.34 units. The Methods have been corrected. Table 2 now also reports the original colour of each tooth before staining; the teeth were very similar (L* coefficient of variation 1.7%).
Whether substrate variation affected all materials equally: We agree that reusing the same teeth balances the design but does not show an equal effect. We therefore fitted a repeated-measures (split-plot) ANOVA to all 375 readings. Disk was the subject, tooth was a within-disk factor, and material and layering configuration were between-disk factors. Within-disk effects were tested with the Greenhouse–Geisser correction.
- Colour change (ΔEab). Tooth had a large effect, accounting for 53% of the total sum of squares. This reflects differences in staining severity: the more heavily stained teeth produced larger colour changes. Its interactions with material and configuration were statistically significant but small (together 0.7% of the sum of squares), and the materials ranked identically on every tooth in every configuration.
- Colour difference from the original colour (ΔE₀₀). Tooth accounted for only 10% of the sum of squares, compared with 51% for layering configuration and 23% for material. The tooth interactions together accounted for 3.3%. Material × tooth (F = 24.0) and configuration × tooth (F = 73.8) were significant (p < 0.001 after Greenhouse–Geisser correction, ε = 0.78), so substrate did not affect all materials exactly equally. Nevertheless, the main conclusions held on every substrate. The blocker configuration was closest to the original colour for every material on every tooth, A-UNO was the closest material in 14 of the 15 tooth × configuration combinations, and no reading on any tooth reached the acceptability threshold.
These analyses have been added to the Results (Tables 5 and 6), and the remaining qualification to the Limitations.
Changes: Section 2.3 (selection criterion; laboratory specimen numbers of T1–T5), Section 2.5 (lines 175–180), new Table 2, Results (Tables 5 and 6), Discussion, Limitations.
4 The precision of the means has limited practical interpretation
Figures 2 and 3 pool distinct materials or layering conditions, while Figure 4 separates these combinations. The narrow intervals in Figure 4 concern means calculated from disk values already averaged over the same five teeth. They do not demonstrate predictable outcomes across different tooth substrates. The strong material-by-condition interaction further limits interpretation of pooled rankings. The confidence-interval calculations in Figure 4 and Table 4 also require reconciliation, and the mixed model needs to be reported fully.
These concerns affect the validity of the outcome and the usefulness of the conclusions. They cannot be resolved by further changes in wording or statistical presentation alone.
Reply: We agree with each point.
- Pooled rankings. Because the material × configuration interaction was strong, pooled rankings are of limited value. Figures 2 and 3, which pool materials or configurations, are retained only as overall summaries. Interpretation now relies on the material × configuration results (Figure 4, Table 4), and the text no longer refers to an overall ranking of materials.
- Predictability across substrates. We agree that the narrow intervals in the previous Figure 4 reflected the precision of the means, not the predictability of outcomes on different teeth. On raw ΔEab, results for the same configuration varied by 11.1–13.4 units across teeth. For the colour difference from the original colour, variation across teeth was smaller (SD 0.7–3.3 ΔE₀₀). Results for each tooth are now reported in Supplementary Table S1 and analysed in Table 6, and, as described under Comment 3, the main conclusions held on every substrate.
- Confidence intervals. The Reviewer is correct. The previous Table 4 gave a confidence interval based on the pooled error term, whereas Figure 4 showed intervals specific to each group. Group-specific 95% confidence intervals (t, df = 4) are now used in all tables and figures, and the pooled-interval note has been removed.
- Mixed model. The repeated-measures model is now reported in full for both outcomes (Table 6). The tables give sums of squares, degrees of freedom, error terms, F, uncorrected and Greenhouse–Geisser-corrected p values, ηp² and variance components. Material, configuration and their interaction were tested against disk within group (df = 60). Tooth and all its interactions were tested against tooth × disk within group (df = 240; Greenhouse–Geisser ε = 0.78 for ΔE₀₀ and 0.52 for ΔEab). All within-disk effects remained significant after correction (p < 0.001).
Changes: Figures 2–4 (corrected Omnichroma data and group-specific 95% CIs), Tables 3–6, Statistical analysis, Results, Discussion.
We are grateful for the Reviewer's persistence on these points. Colour change alone could not establish masking performance. With the original tooth colour as a defined target, the study now shows three things. None of the tested configurations restored the original colour within clinical acceptability. A thin opaque blocker consistently gave the closest approach, and increasing composite thickness was not an effective substitute. The magnitude of colour change does not predict the quality of the final colour match. The remaining limitations are stated explicitly: the unstandardised measurement conditions, the absence of a layering comparator, the flat specimens, the bovine substrates and the lack of visual assessment.
Reviewer 3 Report
Comments and Suggestions for AuthorsAccept in current form
Author Response
Thank you for the positive feedback and kind guidance.
Round 3
Reviewer 2 Report
Comments and Suggestions for AuthorsI thank the authors for their substantial revision and careful responses to the previous comments. The comparison with the original pre-staining tooth colour, the revised statistical analysis and the clearer reporting of limitations represent meaningful improvements. The study now has potential value as an exploratory laboratory investigation, and I therefore change my recommendation to major revision. The following issues should be addressed before acceptance can be considered.
1 Scope and interpretation
Align the title, abstract and conclusions with the actual outcomes: colour change and matching the original pre-staining tooth colour. Avoid equating colour change with masking ability. Give appropriate emphasis to the ΔE00 analysis and explicitly identify it as an analysis introduced during revision.
2 Optical measurement limitations
The lack of standardised optical coupling, positioning, contact pressure and hydration may affect comparisons between configurations, particularly because the blocker introduces an additional interface. Low variability among disk means does not exclude systematic bias. Describe the blocker result as an observation in this unbonded experimental model. Retaining claims of intrinsic material superiority or clinical benefit would require further controlled validation.
3 Clinical conclusions
Remove the implication that the blocker configuration preserves more tooth structure. Both 0.5 mm blocker plus 0.5 mm composite and 1.0 mm composite have the same total thickness, and different preparation depths were not tested. Restrict conclusions to the configurations and substrates investigated.
4 Data transparency
Please ensure that Supplementary Table S1 is available for review, including the original, stained and covered CIELAB coordinates and tooth and disk identifiers. Clarify the allocation and reuse of blocker disks. These data are necessary to verify the new analysis and the correction of the interchanged Omnichroma configurations.
Subject to satisfactory verification of the corrected data and appropriately restricted conclusions, I would be willing to reconsider the manuscript for publication.
Author Response
We thank the Reviewer for the positive reassessment and the revised recommendation, and for the constructive comments in this round. We agree with each point. The title, Abstract, Discussion and Conclusions have been revised so that they reflect only the two outcomes measured: the colour change produced by coverage (ΔEab) and how closely the covered specimen matched the original, pre-staining tooth colour (ΔE₀₀). The blocker results are now presented as an observation in this unbonded laboratory model, and all statements that implied preservation of tooth structure or intrinsic clinical benefit have been removed. The complete dataset is provided in Supplementary Table S1. Our point-by-point responses follow; all changes are highlighted in the revised manuscript.
Comment 1 – Scope and interpretation
Response: We agree. The manuscript has been aligned with the two outcomes measured, as follows:
- Title. The title now names both outcomes: “Color Change and Color Match of Universal-Shade Resin Composites over Discolored Tooth Structure: Effect of Thickness and an Opaque Blocker-An Exploratory In Vitro Study.”
- Abstract. The Abstract now reports the two outcomes separately and gives the ΔE₀₀ results equal weight. It states that the ΔE₀₀ comparison with the original tooth colour was introduced during peer review, and it no longer uses “masking” to describe the outcome.
- Methods. Section 2.5 now states that the ΔE₀₀ analysis was added during revision, using pre-staining colour measurements recorded before the experiment.
- Discussion and Conclusions. Colour change is no longer equated with masking ability. Wherever “masking” remains, it refers to previous studies or to the masking reference that could not be established. The Conclusions now report the ΔE₀₀ findings alongside the ΔEab findings, and state explicitly that a larger colour change did not correspond to a closer match with the original colour.
Changes: Title, Abstract, Keywords (“masking” replaced by “color matching”; ΔE00 added), Aim (“exploratory”; objective 4 identified as added during peer review), Section 2.5, Discussion, Limitations, Conclusions.
Comment 2 – Optical measurement limitations
Response: We agree that low variability among disk means does not exclude systematic bias. Because the coupling medium, positioning, contact pressure and hydration were not standardised, and because the blocker configuration contains an additional optical interface, the differences between configurations may partly reflect the measurement set-up rather than the materials alone. We have made the following changes:
- Argument withdrawn. We withdraw the argument in our previous response that the low variability among disk means limited the effect of the uncontrolled conditions. No such claim is made in the manuscript.
- Blocker findings reworded. The blocker results are now described throughout as an observation in this unbonded experimental model (for example, “in this unbonded laboratory model, the blocker configuration showed the smallest difference from the original tooth colour”). Statements that the blocker “was more effective” or “is preferable” have been removed.
- No claims of superiority or clinical benefit. The Discussion now states that the material and configuration differences observed cannot be taken as evidence of intrinsic material superiority or clinical benefit. Confirming them would require controlled validation, with a defined coupling medium, standardised positioning and contact pressure, bonded specimens, and visual assessment. We also explain that the extra interface could bias the blocker configuration in either direction.
- Limitations strengthened. Measurement bias between configurations is now presented as a principal limitation of the comparison, not only of reproducibility.
Changes: Discussion (blocker paragraphs), Limitations, Conclusions.
Comment 3 – Clinical conclusions
Response: We agree, and we thank the Reviewer for pointing this out. The 0.5-mm blocker plus 0.5-mm composite and the 1.0-mm composite have the same total thickness, and different preparation depths were not tested. The study therefore provides no evidence that either option preserves more tooth structure. We have made the following changes:
- Aim. The description of a chairside choice between removing more tooth structure and placing a blocker has been removed. The comparison is now described as two ways of filling the same 1.0-mm thickness: a single composite layer, or a blocker beneath a thinner composite layer. A third configuration uses 0.5 mm of composite alone.
- Clinical implications. The sentence comparing the blocker with “removing additional tooth structure to obtain a 1.0-mm composite layer” has been deleted, together with the related recommendation. The paragraph now states only that, at the same total thickness, the blocker configuration showed the smallest difference from the original tooth colour in this unbonded model. It also notes that clinical relevance would need to be confirmed in controlled and clinical studies.
- Conclusions. The conclusion that “a thin opaque blocker is preferable to increasing composite thickness” has been removed. All conclusions are now restricted to the five materials, three configurations and five tea-stained bovine substrates investigated.
- Discussion. The paragraph on minimally invasive dentistry now refers only to the effect of thickness observed (0.5 mm vs. 1.0 mm), without implying that one configuration saves tooth structure.
Changes: Aim (Section 1), Discussion (thickness and clinical implications paragraphs), Conclusions.
Comment 4 – Data transparency
Response: We apologise that the supplementary file was not available to the Reviewer. Supplementary Table S1 has been uploaded with this revision as an Excel workbook containing four sheets:
- Table S1: all 375 readings. Each row gives the material, layering configuration, disk number and unique disk ID, and the tooth (T1–T5 with its laboratory specimen number). It also gives the L*, a* and b* of the covered specimen, ΔEab, and ΔE₀₀ to the original colour.
- Tooth readings: the three individual readings of each tooth before staining (original) and after staining (baseline).
- Tooth colors: the mean original and stained L*, a* and b* of each tooth, and the colour difference produced by staining (Table 2 of the manuscript).
- Disk means: the 75 disk-level values used in the two-way ANOVAs.
All colour differences in the manuscript can be recalculated from these coordinates.
Omnichroma correction. On the original recording sheet for Omnichroma, the columns were ordered 0.5 mm, 1.0 mm, blocker + 0.5 mm, whereas on the sheets for the other four materials they were ordered 0.5 mm, blocker + 0.5 mm, 1.0 mm. The dataset used for the first revision assumed the common order, which interchanged the two Omnichroma configurations. In Table S1, the Omnichroma data follow the labels of the original recording sheet. The corrected assignment is consistent with the other materials. For each of the other four materials, the blocker configuration produced the highest b* of the three configurations, that is, the smallest loss of yellowness relative to the original colour. With the corrected labels Omnichroma shows the same pattern (Δb* −6.3 with the blocker, vs. −16.6 at 0.5 mm and −17.1 at 1.0 mm), whereas the previous assignment did not.
Allocation and reuse of blocker disks. Five Omnichroma Blocker disks (0.5 mm) were fabricated and randomly numbered 1–5. For each material, blocker disk n was paired with the composite disk bearing the same number (1–1, 2–2, 3–3, 4–4, 5–5). Each composite disk was therefore tested with only one blocker disk, and blocker and composite disks were not combined in every possible pairing. The same five blocker disks were used under all five composites, so each blocker disk was used once with each material, and each blocker–composite pair was measured over all five teeth. In Table S1, the blocker disk used in each reading is identified by the same number as the composite disk. This is now stated in Section 2.4. Because the same blocker disks were shared across materials, comparisons between materials in the blocker configuration are not fully independent, and this is noted in the Limitations.
Changes: Supplementary Table S1 (expanded), Section 2.4, Limitations.
We thank the Reviewer again for the careful verification of our work over several rounds. The manuscript is now presented as an exploratory laboratory study. Its conclusions are restricted to colour change and match to the original tooth colour for the materials, configurations and substrates investigated, and the blocker findings are qualified as observations in an unbonded model. The complete dataset is available for verification. We hope the revised manuscript is now suitable for publication.