Abstract
Microbial fuel cells (MFCs) utilizing livestock wastewater represent a critical path toward sustainable energy and net-zero emissions. To maximize this potential, this study investigates a novel circuit configuration, integrating twin MFCs with dual supercapacitors in a closed-loop system, to enhance charge storage and electricity generation. By utilizing molasses-seawater anolytes, the study establishes a performance benchmark for optimizing energy recovery in future livestock wastewater treatment applications. The self-adjusting potential difference between interconnected MFCs is verified, and supercapacitors significantly improve energy harvesting by reducing load impedance and balancing capacitor plate charges. Voltage gain across supercapacitors exceeds that of single MFC charging, demonstrating the benefits of series integration. Experimental results reveal that catholyte properties—electrical conductivity, salinity, pH, and dissolved oxygen—strongly influence MFC performance. Optimal conditions for a neutralized anolyte (pH 7.12) include dissolved oxygen levels of 5.37–5.68 mg/L and conductivity of 24.3 mS/cm. Under these conditions, supercapacitors charged with sterile diluted seawater catholyte store up to 40% more energy than individual MFCs, attributed to increased output current. While the charge balance mechanism of supercapacitors contributes to storage efficiency, its impact is less pronounced than that of conductivity and oxygen solubility. The interplay between electrochemical activation and charge balancing enhances overall electricity harvesting. These findings provide valuable insights into optimizing MFC-supercapacitor systems for renewable energy applications, particularly in livestock wastewater treatment.
1. Introduction
Most recent studies about microbial fuel cells (MFCs) and energy harvesting are well-reviewed, and some real-world applications have been discussed [1]. In Taiwan’s pig farms, more than 50% of the electricity is used to provide wastewater treatment equipment, and the power structure primarily relies on thermal power generation. Our research team has successfully developed a pig wastewater microbial fuel cell module in coordination with piggery wastewater [2]. To further enhance the efficiency of this fuel cell module, it is urged to identify parameters that can improve its performance through simple research experiments for reducing carbon emissions. The MFC was used to charge a capacitor, and the displacement current was analyzed in the frequency domain using the Fast Fourier Transform (FFT). The analysis showed that the displacement current had both DC and AC components, which were attributed to the behavior of the exoelectrogen population [2]. Moreover, the performance of MFCs has been studied in all aspects possible in recent years, from electrode materials, biofilm formation, anaerobic system structure, circuit configuration, substrate parameters, including composition, concentration, acclimation conditions, and electrolyte operating conditions such as loading rate and hydraulic retention time [3]. Specifically, the voltage and current produced by a single microbial fuel cell are less than 1 V and in the range of μA-mA, respectively [2,4]. Due to the limited output voltages and current, applications of MFCs were constrained, which affected the perspective on applicability in the future [5]. MFCs are connected in either series or parallel to enhance output voltage or current to address the issue of low-output electricity [6]. If MFCs are connected in parallel, the output current can increase, but the output voltages cannot be enhanced theoretically. A stack of MFCs in series is a straightforward concept and a feasible method for improving the MFC voltage performance. Usually, when two cells are connected in series, the total voltage of the two-cell system is equal to the sum of the unit-cell voltages. To keep all the individual MFCs operating under optimized conditions, plentiful electro-biochemical research has been carried out to enhance the electricity generation of MFCs when connected in series [7].
However, many inherent constraints result from forming a shunt current, voltage reversal (VR), and current reversal when MFCs connect in series or parallel [8,9,10]. The VR effect primarily aggravates the output voltage of MFCs connected in series. Because the VR phenomenon has limitations in energy output and system stability, current research is focused on improving the way organic waste is converted into sustainable energy and reducing voltage reversal. The primary aim of this research is to balance the state of current production (SOCP) for each cell unit or modify energy extraction methods. This includes optimizing circuit designs for energy extraction, manipulating resistance through techniques such as internal resistance control or threshold resistance adjustment, and integrating capacitors with circuit controls. These controls may involve parallel and hybrid connections, maximum power point tracking (MPPT), and power management systems to improve the steady-state energy output performance of the system [7].
Supercapacitors were charged in parallel by the MFCs and discharged in series to the external load to avoid voltage reversal [11]. Sediment microbial fuel cells (SMFCs) connected in series to charge supercapacitors, which are then used to drive the DC boost converter and power management system (PMS) of SMFCs [11,12]. When MFCs are connected in series, the primary cause of the VR effect is that electroactive bacteria are assumed to be capable of both oxidation and reduction reactions between serially connected electrodes with opposite polarity [13]. Hence, VR was found to obstruct electricity generation due to the self-compensated effect on electrochemical activity in the anode and the cathode chambers between different MFCs [14,15]. Since controlling VR is advantageous to the applicability of MFCs connected in series, through designing electronic circuits, increasing the output electricity of MFCs in a combination of parallel and series connections, and manipulating the internal resistance, mitigating VR has been extensively studied to enhance the performance of stacked MFCs [7].
Due to the electroactive bacteria inherently acclimatizing to changes in the operation conditions for MFCs, the imbalance of electrochemical activity between MFCs is unavoidable. The polarity of the output voltage and the current direction of each MFC connected in series should remain the same, and the generated electrons should be retained in the circuit. To optimize the performance of MFCs connected in series, the basic concept is to keep all the individual MFCs operating in similar oxidation-reduction reactions when connected in series. Moreover, acclimation of the inoculum can shorten the startup of MFCs [16].
This research aims to facilitate the acclimatization effect of the electroactive bacterial consortium between MFCs and enhance the energy storage of charging capacitors by MFCs indirectly connected in series. A circuit configuration of two MFCs interconnected with two capacitors was proposed to mitigate the VR effect. The feasibility and validity of the proposed circuit configurations are verified by optimizing charge storage. However, the validity of circuit configuration requires knowledge of the optimized performance of MFCs before being verified, which will be detailed in the experimental setup section.
2. Materials and Methods
2.1. Microbial Fuel Cell Design
A typical MFC consists of two compartments, an anode and a cathode, separated by a separator or membrane such as a proton exchange membrane (PEM). The MFC was a tubular two-chamber assembly developed that allowed pH value self-adjustment in both compartments. The MFC architecture for this study is a tubular two-chamber reactor configuration that incorporates features of an air-cathode that contacts with air (Figure 1a).
Figure 1.
(a) Experimental setup of a single microbial fuel cell (MFC) and (b) a loop circuit for supercapacitor charging with multiple MFCs.
Two biochar electrodes were used as the anode and cathode. The reactor consisted of an upper cathode chamber with a 0.35 L volume and a lower anode chamber of 0.5 L, which was separated from the cathode chamber by an eggshell membrane (ESM). The ESM (thickness, 50–70 µm) has native antibiotic capability due to its fibrous structure and surface chemistry, through which bacteria cannot pass through the overlying hydrophilic ESM from anolytes to protect the cathode against biofouling [17]. MFC’s biochar electrodes of highly porous form have a specific surface area of 400 to 800 m2/g and have a typical pore size of 50 nm–2 mm [18]; the 24.7 g tubular-shaped biochar electrodes with a length of 8.5 cm and diameter of 2 cm have 3D porous structure, which can enhance bacterial consortium attachment [6], extracellular electron transfer for electrodes, and capacitance of electrodes [19,20].
One end face of the versatile anodic electrode was covered with a layer of the ESM as a substitute for PEM, plugged into the end opening of the cathode chamber, and immersed in the catholyte (Figure 1a) [21]. The other end of the anode was immersed in the anolyte and connected with a wire to the negative side of the capacitor, while the cathode electrode was connected to the positive side. The interface between the anodic electrode and catholyte was effectively sealed with thin white Teflon tape, with which the catholyte was kept from leaking. The two chambers were joined tightly with tape, and the electrogenic bacteria in the anode chamber could proceed with anaerobic digestion using biomass. Since proton ions and other cations transport through the ESM from the anolyte to the cathode chamber is inescapable, the micro-pores of the biochar anode can pull the anolyte through capillary action against gravity. The anode with ESM functions as a microfiltration separator, which hinders the transfer of the fuel and bacteria to the cathode and reduces the pH gradient across the ESM. Hence, the ESM can mitigate substrate and oxygen crossover and biofouling of the cathode [21]. Attaching the ESM to one end of the anode can reduce the internal resistance with shortened inter-electrode distance, which increases the proton transfer rate and decreases oxygen permeability [22]. Therefore, this separator electrode assembly reduces the internal ohmic losses of cells.
The anode chamber was fed with a sterile 500 mL mixture, as synthetic wastewater, containing molasses (pH = 4.97, Taiwan Sugar Corp., Tainan, Taiwan), seawater (pH = 7.66), and 0.5 M NaHCO3 as the anolyte. The mixing ratio of sterile molasses and seawater (salinity = 35 g/kg) is 1:1 (v/v). The bacterial consortium of diluted piggery sludge (1:100, v/v) was the biocatalyst with a 1% inoculation rate for MFC operation. The addition of NaHCO3 was used as a buffering agent to optimize the pH of the anolyte. Moreover, the purified bottled water, seawater, and diluted seawater (salinity = 16 g/kg) were individually used as the catholytes for this study. All anolytes were autoclaved to ensure the sterile conditions of the anolytes before performing any experiments.
2.2. Conductivity of the Anolyte and Catholyte
Most influents used as a substrate have low solution conductivity, and there is a linear relationship between electrical conductivity and salinity [23]. Hence, the electrical conductivity of the anolyte and catholyte can be enhanced jointly by increasing salinity [3]. The addition of NaCl also enables the direct electron transfer from the electrogenic microorganism to the electrode and increases catalytic activity in the catholyte [23,24]. The increased catalytic activity could be ascribed to the increasing ionic strength of the anodic substrate, which can also decrease the cathode impedance [25]. High-saline wastewaters as an anolyte and the addition of salt in the electrolytes were proposed previously [26,27]. However, some studies have also shown decreased organic degradation efficiency with increasing substrate salinity in contrast [26]. Microbial variety has many functions, and most bacteria can be employed as a biocatalyst in a microbial fuel cell (MFC) [28]. However, there exists a salinity tolerance of anaerobic metabolism activity for bacterial consortium in the anode; excess salinity will inhibit the activity of electrogenic microorganisms and cause an internal resistance loss [29]. Therefore, an appropriate formula of electrolyte increase in salinity increases the ionic strength, improves substrate degradation, and changes the dominant microbial community structure in anolytes [30]. The addition of electrolytes to seawater increases conductivity to diminish the internal resistances, improving the MFC’s performance.
2.3. Solubility of Oxygen in Seawater
Since the solubility of oxygen in seawater will vary depending on diffusion length, the solubility of oxygen decreases as diffusion length increases. For producing water in the oxygen reduction reaction (ORR), the lower the seawater level, the faster the oxygen in the air can diffuse into the catholyte. However, the optimized depth from the catholyte level to the eggshell should be larger than the oxygen diffusion length to prohibit oxygen transfer to the anode. When the cathode chamber was filled with 250 mL sterile seawater or sterile diluted seawater to increase the electrical conductivity, which is just enough to immerse the electrode, it improved the electron transfer from the electrode to oxygen.
2.4. pH of the Anolyte and Catholyte
The organic matter (substrate) oxidation through the anaerobic respiration process releases protons, electrons, and biogas, including CO2, in the anode chamber [31]. Hence, the more protons generated during substrate degradation, the more the anolyte becomes acidic. Furthermore, the acidified anolyte can dramatically decrease bacterial activity and affect the electron transfer rate at the anode [32]. For ORR in the air-cathode chamber, the hydroxide-ion-generating reduction reactions occur due to low proton concentration caused by low proton diffusion rate from the anolyte; the electron acceptors (O2) receive electrons from the cathode and combine with water to form hydroxide ions, which results in a pH increase [33]. The increased pH in the cathode compartment can also significantly decrease the current generation [34].
Therefore, acidified anolyte and alkalized catholyte inevitably occur and cause a reduction in the overall performance. The occurrence of the pH difference between the anode and cathode with time aggravates the pH imbalance and decreases the current generation; the pH imbalance produces a 0.059 V/pH potential loss [35]. The optimal pH is 8–11 for the growth of electrogenic microorganisms [35]. Previous research neutralized the acidified anolyte by adding NaOH or HCl and using anodic effluent as the influent for the cathode [36,37,38]. Water and CO2 can react to produce carbonic acid (H2CO3), and break into hydrogen ions (H+) and bicarbonate ions (HCO3−). In this study, in addition to adding NaHCO3 in the anolyte, by the solubility of CO2 in water, the generated CO2 can also be driven into the catholyte to improve pH, alkalinity, and conductivity [35,39].
There is a 1 cm air gap between the anodic electrolyte level and the ESM to provide space for collecting biogas (Figure 1a). A set of 2 mm diameter biogas channels were drilled into the anode electrode and perpendicular to each other (Figure 1a). This work can be adapted for a pH value self-adjusting mechanism to optimize the pH imbalance between the anode and cathode chambers. The outgassing biogas, including CO2, can be directly diffused from the anode chamber into the catholyte via the eggshell and acidify the catholyte. The CO2 in the anode chamber was pumped into the catholyte under increasing biogas pressure to reduce the catholyte’s alkalization to lower the pH imbalances between the two chambers (Figure 1a). Therefore, the more acidified anolyte and alkalized catholyte, the more CO2 and neutralization are produced. It is an effortless process for self-adjusting the pH values of electrolytes. This pH adjustment strategy in MFC compartments can maintain reliable performance and remarkably increase the output cell voltage. The pH, dissolved oxygen (D.O.), electrical conductivity (E.C.), and salinity were measured using a pH meter (PH200, TWINNO Instrument, Taiwan), electrical conductivity meter (CON200, TWINNO Instrument, New Taipei City, Taiwan), dissolved oxygen meter (DO200, TWINNO Instrument, New Taipei City, Taiwan), and Salinity Refractometer (MASTER-S/MillM, Atago, Tokyo, Japan), respectively.
2.5. The Internal Resistance
The internal resistance (Rint) is the critical parameter in MFCs, which varies with diverse factors such as electrical conductivity and pH value of electrolytes, electrode materials and geometry, and separator characteristics [40]. Hence, Rint is a nonlinear function of current and causes an inevitable internal energy loss [41]. Since the current flow in microbial fuel cells also strongly depends on the external load, the current flow in MFCs strongly depends not only on the internal resistance but also on the external load [40]. Previous studies show that varying external resistances would significantly affect the anode biofilm morphology and thickness, depending on single or mixed-culture inoculated MFCs [42]. High external resistance results in the microbial population evolving from electrogenic to fermentative microbial culture [43]. However, a smaller external resistance leads to a higher maximum power density [42]. Hence, this study intends to control internal resistance (Rint) as a function of external resistance (Rext) for optimal MFC electricity storage under different operating conditions.
2.6. Supercapacitor as the Storage Device
Since the generated electrical energy should be stored in a capacitor for utilization, once a capacitor with an external load is connected to a voltage source such as MFCs, it will be charged up to a rating voltage that the power source can provide. A supercapacitor has low external impedance at low frequencies due to its large capacitance and low equivalent series resistance (ESR). To mitigate the slow output power rate of MFCs, supercapacitors can provide an external load equivalent to a nearly short-circuit connection to maximize the current output and be used as an electrical energy storage device for a long operation time. The in situ monitoring of electricity generation of MFCs has been studied using livestock wastewater as fuel by our research team; their results showed that the electricity-generating rate of the electrogenic bacterial consortium may be limited to tenths of a hertz (decihertz, dHz) [2]. Therefore, the impedance of supercapacitors is negligible due to the low electricity generation rate of electrogens and their large capacitance. Hence, the supercapacitor is ideal for acting as an external load impedance to lower its effect on the internal resistance and electricity storage device; it also can provide in situ monitoring of the number of stored charges from the time-varying voltage differences across its plates for optimizing operation conditions of MFCs.
2.7. Experimental Setup
The circuit configuration designed for this study enables the simultaneous increase in charge storage of two coupled 370F (LICAP) supercapacitors with equivalent series resistance of 2.8 mΩ, and the enhancement of the output current of MFCs (Figure 1b). The dominant electricity-generating rate of the electrogenic bacterial consortium is around 0.25 Hz, and the impedance of the supercapacitor is 1.7 mΩ at 0.25 Hz [2]. The 370 F supercapacitor can withstand up to 2.5–2.7 V, and the current and the voltage across the supercapacitor were measured by a data logger (ADAM-4117-B, Advantech, Taipei, Taiwan) connected to a computer [44]. The voltage changes across each MFC and the current can be measured in seconds in real-time. Two circuit configurations of MFCs and capacitors were conducted as follows: (a) a single MFC charged an individual capacitor as a reference for charging efficiency (Figure 1a), and (b) two MFCs were interconnected with two capacitors in series (Figure 1b). The MFCs operated in both configurations were conducted synchronously, and voltage and current were recorded for comparison and data analysis. All MFCs were used in one fed-batch mode for four days under ambient temperature conditions of 27.4 ± 1.7 °C and 33 ± 10% relative humidity.
2.8. Charging Circuit Design
The components of an MFC are the anode, cathode, ion-permeable membrane as a separator, and external circuit. The electrogenic bacterial consortium resides in the anode and produces electrons and protons by biomass degradation. The electrons produced are transported from the anode to the cathode via an external circuit. The cathode produces water by combining electrons, oxygen, an electron acceptor from air, and protons, which traverse through the membrane to the cathode. Therefore, there is a proton concentration gradient between the anode and cathode, and a considerable number of cations, including protons, diffuse from the anode to the cathode via the compartment separator, producing a current flow of cations inside the MFC. The circuit interconnects two supercapacitors (C1 and C2) between two individual and identical MFCs (MFCa and MFCb), respectively, and shows the potential energy transfer track of the sub-current, which starts at the anode of MFCa and traces a path around the circuit, returning to the original node (Figure 2).
Figure 2.
(a) Path of electrons and ions transport inside MFC, and (b) schematic potential energy transfer flow of MFCs for charging capacitors.
The proposed circuit, based on charge balance over capacitors, is to realize the gain of charges stored in the capacitor (Figure 2a). Cathodes and anodes of MFCs were interconnected with positive and negative plates of two different supercapacitors with the same capacitance (C1 and C2), respectively. Moreover, cathode 1 and anode 1 represent the cathode and anode of MFCa, respectively (Figure 2b). The same notation is for cathode 2 and anode 2 of MFCb. The arrowhead indicates the current flow direction in the circuit. Both of the MFCs charged the two capacitors at the same time. Two sub-currents in the circuit loop merge, each originating from the anodes inside MFCs. The two sub-currents flow in the same direction around the loop and traverse through the coupled capacitors by charge balance over the capacitors. Finally, the two sub-currents return to their anodes via capacitors, since the negligible impedance of the external load in the circuit, that is, the total sub-current in the circuit, equals the summation of the electromotive force divided by its internal resistance for each MFC.
2.9. Working Principle of Loop Current Analysis
The loop current analysis working principle involves these key steps. When connected to an external circuit, current flows through wires via electrons released from the anode, rather than anions. In the setup, the negative plate of capacitor C2 connects to anode 1 of MFCa, while its positive plate connects to cathode 2 of MFCb. Electrons from anode 1 of MFCa travel to C2’s negative plate, inducing an equal number of positive charges on its positive plate to maintain charge balance across C2. At cathode 2, dissolved oxygen in the catholyte captures electrons repelled from C2’s positive plate. This oxygen reduction produces hydroxide ions (OH−) using electrons generated at anode 1, indirectly linking anode 1’s oxidation to cathode 2’s reduction.
Meanwhile, cations (including protons) diffuse from anode 2’s anolyte to cathode 2, gaining potential energy. Thus, the total positive charge on C2’s positive plate sums induced charges from anode 1 electrons on the negative plate plus additional positive charges from cathode 2. Electrons from anode 1 also accumulate on C2’s negative plate, inducing further electrons from cathode 2. Both capacitors charge simultaneously via the two MFCs.
Per the law of mass action, enhanced electron supply at cathode 2 accelerates MFCb’s reduction rate, rapidly producing OH− that raises catholyte pH and alkalizes it. This alters anion and cation concentrations as capacitor charge storage grows, accelerating cation diffusion and anion flow in MFCb. The resulting voltage gain across C2, from enhanced charge balance, indicates total output from both MFCs. Symmetrically, for MFCb’s anode, electrons accumulate on C1’s negative plate as the sum from anode 2 plus those induced by positive charges from cathode 1. C1’s charge storage follows the same capacitor charge balance principle, with increasing stored electricity.
This deduction implies that the negative plates of the capacitor effectively act as an anodic electron pump to enhance the microbial oxidation of organic substrate and produce more cation current flow. Therefore, the ion transportation and electricity generation efficiency in MFCs gradually self-accelerate during the energy transfer cycles. Due to dissimilar electrochemical kinetics, the cell potential difference between MFCs can be mitigated with charge balance over the capacitors when connected in series. Two cells charge the capacitors concurrently to aggregate the total internal energy loss. It should be more significant than that of an individual cell.
The interactions between capacitors and MFCs can enhance the sub-currents originating from anodes. This process enhances the production of total current flow and electricity. The current flow completes one cycle in MFCs, and the current cycle process continues until the current flow through the charging system is steady. Eventually, the charges stored in capacitors are equal due to being charged in series with the same current in the loop by the same pair of cells simultaneously, while the cycle repeats. The total current is increased without the VR effect by summing the two sub-currents.
Furthermore, when loop analysis is applied to Kirchhoff’s voltage law for the circuits containing MFCs and supercapacitors, the sum of the potential differences across all the elements around the closed-circuit loop must be zero, i.e., the potential energy is conserved in the circuit. Both V1 and V2 are the voltages across the capacitors (C1 and C2), which are charged with the same current, and V1 = V2. Since an electromotive force (EMF) is the energy gained per unit electric charge inside MFC from anode to cathode (Figure 2a), the voltage changes across MFCa and MFCb are Va and Vb, and the EMF for MFCa and MFCb are εa and εb, respectively. Regarding the potential change in MFCa, MFCa, which is the source of EMF, is traversed in the direction of the current or proton flow (from anode to cathode), and the change in the electric potential is positive, increasing potential energy by εa (Figure 2b). At the same time, the internal resistance is traversed in the direction of the current, and the potential change across the internal resistance is negative. Φa is the potential energy losses per unit electric charge, including ohmic loss and activation loss, and the total voltage change across MFCa is Va and Va = εa − Φa. As in MFCb, the voltage drop Vb equals εb − Φb, where Φb is defined as the same as Φa. However, the total internal potential energy loss Φloss in the loop can be self-compensated by the potential energy stored in capacitor C2 when the current flows back to the anode of MFCa, which results from the gain of stored charges on the plates of capacitor C2, not only from MFCb but also from MFCa, as in capacitor C1. Therefore, Va + Vb = V1 + V2 due to potential energy conservation in the loop (Figure 1b). This equation can evaluate the consistency of experimental data in the proposed model.
Ideally, both Va and Vb should be positive, εa > Φa and εb > Φb, to drive sub-currents for MFC operation. Instead of Va < 0 and Vb < 0, when εa − Φa < 0 and εb − Φb > 0, Va and Vb have opposite signs that imply that εa is insufficient to overcome the internal resistance losses, and only MFCb can generate a sub-current to charge capacitors in the loop concurrently. Eventually, Va will become positive, caused by the enhancement of electrochemical kinetics due to the charge balancing over capacitors. Therefore, the charge balance over the capacitor and charge conservation in the loop effectively enhance the generated current of MFCs. In addition to cell architecture and electrode materials, both anolyte and catholyte in chambers must be optimized to maximize capacitor charging. The same scenario analysis should be valid for multiple MFCs interconnected in series with capacitors.
In summary, to address the energy losses caused by the variations in total internal resistance, the enhancement of charge storage of supercapacitors can be achieved (Figure 2). The functions of supercapacitors are to (a) store electrons coming from the anodes and (b) bridge the two MFCs connected in series by charge balance between the plates of capacitors. However, this charge balance over the capacitor occurs between electrodes with opposite polarity of different MFCs; therefore, a gain in storing electricity can be obtained. However, this self-adjusting potential difference between MFCs is theoretically feasible, but further experimental confirmation is needed. Finally, an experiment was conducted to evaluate this innovative concept of using capacitors to enhance electricity generation.
3. Results
3.1. pH Effect on Anolyte
The acidification of the anode electrolyte results from the oxidative microbial metabolism of an electrogenic bacterial consortium for organic matter in the anode chamber. However, the acidified anolyte can dramatically decrease bacterial consortium activity and affect the electron transfer rate at the anode. Therefore, the operating conditions of the anode are crucial to generate current flow [45]. In this study, the behavior of the MFCs as a function of the electrolytes applied was evaluated in terms of maximal voltage across capacitors. Anolytes with various pH values have been used to verify the effect of pH value on the performance of MFCs. For a study of pH’s effects on anolytes, seawater of pH 7.66 was used as a catholyte, and mixtures of seawater, molasses, and NaHCO3 with different molarities were used as a substrate in the anode chamber for the supercapacitor charging experiment to verify the optimal pH value of anolytes. There are three different NaHCO3 concentrations, 0.1, 0.5, and 1 M, for studying the pH effect with sterile molasses and diluted seawater analytes. Depending on the increasing concentrations of NaHCO3, the pH value of the catholyte changes from 7.66 to 6.90–7.91, while the pH value of the anolyte increases from 4.97 to 7.17 to 6.04–7.35 at the end of the experiments (Table 1).
Table 1.
The pH values of anolyte (mixture of molasses and seawater) and catholyte (seawater) without/with adding NaHCO3 before and after the MFC operation.
An increase in the anolyte’s NaHCO3 concentrations can neutralize the acidification of the anolyte to enhance biomass degradation. For the anolyte without NaHCO3, an increase in the pH of the anolyte may result from a lack of sufficient biodegradation of molasses by an electrogenic bacterial consortium in acidified anolytes. The acidification of the catholyte is obvious without NaHCO3 and proves the biogas channel’s workability. A more alkalinized catholyte implies a more significant reduction reaction caused by the increasing biodegradation in the anode, which also produces more CO2. Therefore, a more significant CO2 reduces the pH of the catholyte and competes with the increase in the catholyte’s pH caused by the more substantial reduction reaction due to enhanced biodegradation. Hence, the pH values of the catholyte and anolyte strongly depend on the concentrations of NaHCO3, affecting the redox reaction rate. Since sodium bicarbonate is a buffering agent in biochemistry, the increasing NaHCO3 concentrations of the anolyte cannot only neutralize the acidification of the anolyte but also stabilize the pH of anolytes, such as the anolyte with 0.5 M NaHCO3 maintaining a stable pH level. However, excess addition of NaHCO3 can acidify the catholyte, which may be caused by surplus CO2 biogas, in the case of 1 M. Therefore, an overly acidified catholyte results from excess NaHCO3 addition, which produces more CO2.
Figure 3 shows the measured voltages across supercapacitors and current in the circuit for analytes with different concentrations. Figure 3a shows the increased voltages across the supercapacitors with time, and the optimal performance of MFCs is with 0.5 M NaHCO3 for charge storage. The increasing current of MFCs with 0.5 M NaHCO3 anolytes is larger than that of MFCs with 0, 0.1, or 1 M NaHCO3 (Figure 3b). These results depict all the output currents attributed to the charging voltages of supercapacitors. Hence, the current does not increase proportionally with an increase in NaHCO3 concentrations and gradually decreases due to the limited amount of fuel at the end. These results indicate that the pH imbalance effect, including acidified anolytes and alkalized catholytes, on the electrolytes can be mitigated by adding NaHCO3 and dissolving CO2, flushing into the catholyte, and lowering the pH values of the catholyte. This fact also implies that only optimized NaHCO3 concentrations, which neutralize electrolytes, can maximize the current generation in MFCs, and is consistent with the previous study [33].
Figure 3.
(a) Voltages across supercapacitors and (b) measured current versus time for anolyte with different NaHCO3 concentrations and seawater as the catholyte.
3.2. Catholyte Effects
Although the electrical conductivity of the catholyte can be enhanced by increasing salinity, as the salinity in the water increases, the solubility of CO2 and O2 will significantly decrease [46]. Hence, the solubility of O2 and CO2 in water limits the reduction rate at the cathode–air interface in the cathode chamber. Since the total impedance of electrodes could be alleviated by adjusting the electrolyte salinity, the salinity of the catholyte should be optimized to increase the dissolved oxygen and electrical conductivity in the cathode chamber concurrently. The measured voltages across the supercapacitor were used to verify the effects of the conductivity and oxygen solubility of the three different catholytes on the performance of MFCs. Concurrently, a comparison of the voltages across the supercapacitors was made to verify the feasibility and validity of the circuit configuration design. The voltages across the supercapacitors are represented by V1, V2, and V0 for three supercapacitors, C1, C2, and C0, which were charged by MFCs concurrently for comparison, respectively (Figure 1).
The D.O., E.C., and salinity of the sterile purified bottled water, diluted seawater, and seawater were 5.68, 5.37, and 5.65 mg/L, 0.05, 24.3, and 53.6 mS/cm, and 1, 16, and 35 g/kg, respectively. The average pH of sterile purified bottled water, diluted seawater, and seawater was 7.21, 7.42, and 7.66, respectively. Measurement data showed that there is no significant difference between the D.O. ≥ 5 mg/L and pH of those catholytes, but there is between the E.C. and salinity. Notably, there was no significant difference in D.O. after the MFC operation compared with the data before the MFC operation among the three different catholytes. Because of higher D.O. in catholytes, dissolved oxygen was not the limiting factor for this study. However, adequate dissolved oxygen is essential for better performance of the MFCs.
The measured average voltages across supercapacitors and MFCs with three types of catholyte are shown in Table 2. The value of V0 for sterile purified bottled water, diluted seawater, and seawater was 13.9, 31.5, and 12.8 mV, respectively. Since the stored charges are proportional to the voltage drop across capacitors, the sterile diluted seawater is the best choice as the catholyte due to the optimal electrical conductivity meeting the reduction reaction requirements for the catholyte. V1 and V2 each have a 40–60% gain over V0, which implies C1 and C2 each have more stored charge than C0 (Table 2). For the sterile diluted seawater catholyte, the data show that the charge stored in the supercapacitors can achieve a gain of up to 40% compared to an individual cell charging due to increased output current. This result indicates that MFCs connected in series can extract more charges for storing due to the capacitor’s charge-balancing effect. Moreover, it can allow an increase in electricity harvesting by the catholytes’ electrochemical effects and charge balance mechanism of supercapacitors, which interact and reinforce each other. Experimental results also indicate that the potential changes across cells are critical to determining the electricity stored in the supercapacitors for MFCs and supercapacitors connected alternately (Table 2). Since V1 is close to V2 due to both being charged by the same current in the loop, the measured voltages of V1 and V2 are equal to half of Va + Vb. Consequently, the voltage equality V1 + V2 = Va + Vb is verified for all three types of catholyte, as predicted due to energy conservation around the circuit loop. Moreover, when two batteries are connected in series to charge a capacitor, the total supply voltage doubles. Thus, the maximum voltage across the capacitor should be twice that of a single battery at the end of charging. In contrast, when two batteries each charge their own capacitors, the maximum voltage across each capacitor equals that of a single battery. Table 2 also shows that V1 + V2 > 2V0, which implies there is no VR effect (V1 + V2 < 2V0).
Table 2.
Average voltages (mV) across capacitors and MFCs with different catholytes.
However, the average voltage changes across MFCs in series (Va and Vb) have an opposite sign both for the seawater and purified bottled water catholyte (Figure 4). This indicates that the EMF of MFCa cannot overcome the internal resistance to generate current in the loop, resulting in a negative Va. On the other hand, Vb with a positive sign due to the EMF can drive a sub-current inside MFCb. Both of the Vb are increasing slowly due to an enhancement of the rate of electrochemical activity; on the other hand, only Va of the catholyte with purified bottled water (Figure 4a) is slowly increased while that of the catholyte with seawater remains unchanged (Figure 4b). This implies that the internal resistance of MFCa with purified bottled water increases with time gradually, but not MFCa with seawater. These phenomena also confirm that the effect of dissolved oxygen is greater than that of electrical conductivity.
Figure 4.
Comparison of voltage drops Va and Vb over MFCs connected in series with supercapacitors using (a) purified bottled drinking water and (b) seawater as catholytes.
Comparison of voltages across each of the supercapacitors and MFCs connected in series with sterile diluted seawater as the catholyte is shown in Figure 5. However, Va and Vb of MFCs with sterile diluted seawater catholytes in series have the same sign eventually, and the stored charge is maximized compared to other MFCs. In the small current range, Va and Vb rapidly drop due to activation loss increasing sharply, then gradually increasing afterward, disclosing that the activation loss decreases quickly and approaches a smaller steady value [41]. The significant contribution to the internal resistance loss is ohmic loss and activation loss in the current range [47]. Although previously reported, the internal resistance loss remains stable with increasing current [41]. However, the negative value of Va increases from a negative to a positive sign with time, accompanying the positive voltage Vb over MFCb, which also grows as time increases. This growth of Va and Vb implies that sub-currents slowly increase with time due to a gradual reduction in internal resistance loss. In other words, the output cell voltages of both cells are increased with time.
Figure 5.
Comparison of voltages across each of (a) supercapacitors and (b) individual MFCs connected in series with sterile diluted seawater as the catholytes.
Both V1 and V2 are charged up to 44 mV concurrently, while the voltage of V0 is 31 mV. In other words, the gain of the harvest of electric charges for the supercapacitor charging circuit is about 40% (Figure 5a). Based on the mass action law, this result is ascribed to the enhanced sub-currents gradually accelerating the reaction rate of redox reactions of electrolytes in MFCs and producing more output current for charging capacitors in the same period. When comparing with the charging current in the loop circuit, the current of the circuit loop for the individual MFC (I) and the interconnected MFCs (Is) decreases with time and nearly stabilizes after a 4-day time course (Figure 6).
Figure 6.
Comparison of currents in the circuit of MFCs connected in series and a single MFC with sterile diluted seawater as the catholyte for supercapacitor charging.
This result is due to the supercapacitors being charged to act like an increasing external resistance with a building-up voltage drop across each of them; the charging current flows around the circuit and finally diminishes to a constant value. It is worth mentioning that the current in the loop is also higher than that of a single MFC charging circuit (Is > I), as the corollary stated before. This proposed circuit configuration achieves an average 18% gain in current during MFC operation.
The equivalent circuit is the added EMF source that directly drives current via total internal resistance in the circuit, that is, the sum of the internal resistance of each MFC. However, the energy loss resulting from total internal resistance is gradually self-compensated by increased output current due to more biodegradation activation induced by the charge balance over capacitors. As stated above, the two coupled supercapacitors with interconnected MFCs enhance the electricity storage while charging the supercapacitors.
To further verify the proposed circuit’s effectiveness, another experiment replaced the microbial fuel cell (MFC) with three identical AAA-type zinc-carbon cells under the same operating conditions. Voltages across the charging capacitors (C1, C2, and C0) were V1, V2, and V, respectively; voltages across dry cells A and B were Va and Vb. Experimental data (Figure 7) showed that V1 and V2 reached the same saturation voltage at the same current, with charging significantly faster than a single cell. Unlike MFCs—limited by low charging efficiency from microbial electron transfer—the electrochemical cells demonstrated a rapid charging rate exceeding that of a single cell, due to instantaneous charge balance between capacitor plates. Ultimately, all capacitor voltages were nearly identical.
Figure 7.
Comparison of (a) V1, V2, and V, (b) Is and I, and (c) Va and Vb versus time.
In the circuit, one dry cell contributes positive charge to the capacitor plates, while the other contributes the same amount of negative charge. This triggers charge redistribution between the capacitors, allowing dry cell current to flow until their voltages equalize. The process enhances total stored charge, balances potentials across the plates, and boosts dry cell output current, accelerated by the law of mass action in both dry cells. Since capacitor voltage drop is proportional to stored charge, the initial circuit current Is exceeds I due to rapid charge balancing in the supercapacitor. Is then decreases much faster than in a single-cell circuit. The average potential difference across each dry cell (Va and Vb) initially drops at the same rate, then slowly rises to a steady state. This occurs because the two series-connected dry cells simultaneously charge two capacitors, with output current and voltage declining due to gradual charge accumulation on the plates. In summary, the results confirm the feasibility of replacing dual-MFC loops with dry cells. Despite internal energy losses in dry cells, energy harvesting efficiency improves via charge balancing between the supercapacitors.
Therefore, the two MFCs are indirectly connected in series to charge two supercapacitors simultaneously without the VR effect. In summary, the function of electrolytes is to be specialized for redox reactions. To mitigate the VR effect, the specified reactions in anolytes and catholytes are only for oxidation and reduction, respectively. Therefore, the electroactive bacterial consortium of the electrodes should only play one role in the redox reaction. This study underscores the pivotal role of supercapacitors in amplifying electricity generation within microbial fuel cell (MFC) systems through a simple yet effective circuit configuration. By integrating supercapacitors in a looped series arrangement, the circuit leverages charge-balancing dynamics to reduce load impedance and stabilize capacitor plate charges, thereby enhancing biodegradation activity and overall energy harvesting efficiency.
4. Conclusions
Theoretically, there is no limit to scaling the circuit by adding more batteries and capacitors in series. This enables simultaneous charging of multiple units, boosting overall efficiency. However, it also raises total internal resistance. Although electromotive force increases, if it fails to offset this resistance growth, scalability bottlenecks arise. While the circuit accelerates electricity generation, it requires time to overcome internal resistance. Thus, beyond reducing load and resistance, the electric double-layer capacitance (EDLC) effect between battery electrodes and electrolytes must be controlled. Additionally, prolonged operation creates pH differences between the anode and cathode, exacerbating the imbalance and reducing current from single-batch feeds. Solutions are needed to balance pH without external energy while maintaining steady-state current. This study demonstrates that integrating supercapacitors into microbial fuel cell (MFC) circuits significantly enhances electricity generation by leveraging charge-balancing dynamics and reducing load impedance. The series-connected configuration not only improves capacitor charge storage—especially under higher output currents—but also mitigates electrochemical kinetic imbalances between multiple MFCs, enabling more efficient energy harvesting. By adjusting external loads, the system accelerates electrochemical reaction rates, supporting greater biodegradation activity. Furthermore, catholyte properties such as pH, electrical conductivity, salinity, and dissolved oxygen levels critically influence MFC performance, with optimal conditions (e.g., pH = 7.12, D.O. = 5.37–5.68 mg/L, and conductivity of 24.3 mS/cm) enhancing microbial activity and energy output. These findings highlight the synergistic role of circuit design and catholyte composition in advancing MFC-supercapacitor systems for sustainable energy recovery from livestock wastewater.
Author Contributions
Conceptualization, J.-C.S. and J.-J.S.; methodology, J.-C.S.; validation, J.-C.S. and J.-J.S.; formal analysis, J.-C.S.; investigation, K.-C.H., C.-K.L., C.-K.L., A.T., and J.-M.L.; resources, J.-J.S.; data curation, K.-C.H., C.-K.L., C.-K.L., A.T., and J.-M.L.; writing—original draft preparation, J.-C.S.; writing—review and editing, J.-J.S.; visualization, J.-C.S.; supervision, J.-J.S.; project administration, J.-J.S.; funding acquisition, J.-J.S. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the National Science and Technology Council (NSTC), Taiwan, under contract No. NSTC 114-2321-B-002-017.
Data Availability Statement
The original contributions presented in this study are included in the article.
Acknowledgments
The present study acknowledges Prof. Kuei-Yi Lee of the National Taiwan University of Science and Technology for providing the cyclic voltammetry measurement.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| MFC | Microbial fuel cell |
| ORR | Oxygen reduction reaction |
| EMF | Electromotive force |
| PEM | Proton exchange membrane |
| FFT | Fast Fourier Transform |
| ESM | Eggshell membrane |
References
- Serra, P.M.D.; Espírito-Santo, A. Sourcing power with microbial fuel cells: A timeline. J. Power Sources 2021, 482, 228921. [Google Scholar] [CrossRef] [Scilit]
- Su, J.C.; Tang, S.C.; Su, P.J.; Su, J.J. Real-time monitoring of micro-electricity generation through the voltage across a storage capacitor charged by a simple microbial fuel cell reactor with Fast Fourier Transform. Energies 2019, 12, 2610. [Google Scholar] [CrossRef] [Scilit]
- Munoz-Cupa, C.; Hu, Y.; Xu, C.; Bassi, A. An overview of microbial fuel cell usage in wastewater treatment, resource recovery and energy production. Sci. Total Environ. 2021, 754, 142429. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Boas, J.V.; Oliveira, V.B.; Simões, M.; Pinto, A.M.F.R. Review on microbial fuel cells applications, developments and costs. J. Environ. Manag. 2022, 307, 114525. [Google Scholar] [CrossRef] [Scilit]
- Aftab, S.; Shah, A.; Nisar, J.; Ashiq, M.N.; Akhter, M.S.; Shah, A.H. Marketability Prospects of Microbial Fuel Cells for Sustainable Energy Generation. Energy Fuels 2020, 34, 9108–9136. [Google Scholar] [CrossRef] [Scilit]
- Mei, T.; Cong, C.; Huang, Q.; Song, T.S.; Xie, J. Effect of 3D carbon electrodes with different pores on solid-phase microbial fuel cell. Energy Fuels 2020, 34, 16765–16771. [Google Scholar] [CrossRef] [Scilit]
- Kim, B.; Mohan, S.V.; Fapyane, D.; Chang, I.S. Controlling voltage reversal in microbial fuel cells. Trends Biotechnol. 2020, 38, 667–678. [Google Scholar] [CrossRef] [Scilit]
- An, J.; Nam, J.; Kim, B.; Lee, H.S.; Kim, B.H.; Chang, I.S. Performance variation according to anode-embedded orientation in a sediment microbial fuel cell employing a chessboard-like hundred-piece anode. Bioresour. Technol. 2015, 190, 175–181. [Google Scholar] [CrossRef] [Scilit]
- Oh, S.E.; Logan, B.E. Voltage reversal during microbial fuel cell stack operation. J. Power Sources 2007, 167, 11–17. [Google Scholar] [CrossRef] [Scilit]
- Wu, S.; Li, H.; Zhou, X.; Liang, P.; Zhang, X.; Jiang, Y.; Huang, X. A novel pilot-scale stacked microbial fuel cell for efficient electricity generation and wastewater treatment. Water Res. 2016, 98, 396–403. [Google Scholar] [CrossRef] [Scilit]
- Kim, Y.; Hatzell, M.C.; Hutchinson, A.J.; Logan, B.E. Capturing power at higher voltages from arrays of microbial fuel cells without voltage reversal. Energy Environ. Sci. 2011, 4, 4662–4667. [Google Scholar] [CrossRef] [Scilit]
- Prasad, J.; Tripathi, R.K. Effect of sediment microbial fuel cell stacks on 9 V/12 V DC power supply. Int. J. Hydrogen Energy 2021, 46, 14628–14638. [Google Scholar] [CrossRef] [Scilit]
- Chen, S.; Patil, S.A.; Brown, R.K.; Schröder, U. Strategies for optimizing the power output of microbial fuel cells: Transitioning from fundamental studies to practical implementation. Appl. Energy 2019, 233–234, 15–28. [Google Scholar] [CrossRef] [Scilit]
- An, J.; Lee, H.S. Occurrence and Implications of Voltage Reversal in Stacked Microbial Fuel Cells. ChemSusChem 2014, 7, 1689–1695. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- An, J.; Kim, B.; Chang, I.S.; Lee, H.S. Shift of voltage reversal in stacked microbial fuel cells. J. Power Sources 2015, 278, 534–539. [Google Scholar] [CrossRef] [Scilit]
- Zhang, P.; Yang, C.; Xu, Y.; Hai Li, H.; Shi, W.; Xie, X.; Lu, M.; Huang, L.; Huang, W. Accelerating the startup of microbial fuel cells by facile microbial acclimation. Bioresour. Technol. 2019, 8, 100347. [Google Scholar] [CrossRef] [Scilit]
- Park, S.; Choi, K.S.; Lee, D.; Kim, D.; Lim, K.T.; Lee, K.H.; Seonwoo, H.; Kim, J. Eggshell membrane: Review and impact on engineering. Biosyst. Eng. 2016, 151, 446–463. [Google Scholar] [CrossRef] [Scilit]
- Cooney, D.O. Activated Charcoal in Medical Applications; CRC Press: Boca Raton, FL, USA, 2019. [Google Scholar]
- Sreelekshmy, B.R.; Rajappan, A.J.; Basheer, R.; Vasudevan, V.; Ratheesh, A.; Meera, M.S.; Geethanjali, C.V.; Shibli, S.M.A. Tuning of surface characteristics of anodes for efficient and sustained power generation in microbial fuel cells. ACS Appl. Bio Mater. 2020, 3, 6224–6236. [Google Scholar] [CrossRef] [Scilit]
- Peng, X.; Yu, H.; Wang, X.; Zhou, Q.; Zhang, S.; Geng, L.; Sun, J.; Cai, Z. Enhanced performance and capacitance behavior of anode by rolling Fe3O4 into activated carbon in microbial fuel cells. Bioresour. Technol. 2012, 121, 450–453. [Google Scholar] [CrossRef] [Scilit]
- Ma, M.; You, S.; Qu, J.; Ren, N. Natural eggshell membrane as separator for improved coulombic efficiency in air-cathode microbial fuel cells. RSC Adv. 2016, 6, 66147–66151. [Google Scholar] [CrossRef] [Scilit]
- Li, W.W.; Sheng, G.P.; Liu, X.W.; Yu, H.Q. Recent advances in the separators for microbial fuel cells. Bioresour. Technol. 2011, 102, 244–252. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, X.; Cheng, S.; Zhang, X.; Li, X.Y.; Logan, B.E. Impact of salinity on cathode catalyst performance in microbial fuel cells (MFCs). Int. J. Hydrogen Energy 2011, 36, 13900–13906. [Google Scholar] [CrossRef] [Scilit]
- Kumar, S.S.; Kumar, V.; Gnaneswar Gude, V.; Malyan, S.K.; Pugazhendhi, A. Alkalinity and salinity favor bioelectricity generation potential of Clostridium, Tetrathiobacter and Desulfovibrio consortium in microbial fuel cells (MFC) treating sulfate-laden wastewater. Bioresour. Technol. 2020, 306, 123110. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Aaron, D.; Tsouris, C.; Hamilton, C.Y.; Borole, A.P. Assessment of the effects of flow rate and ionic strength on the performance of an air-cathode microbial fuel cell using electrochemical impedance spectroscopy. Energies 2010, 3, 592–606. [Google Scholar] [CrossRef] [Scilit]
- Guo, F.; Luo, H.; Shi, Z.; Wu, Y.; Liu, H. Substrate salinity: A critical factor regulating the performance of microbial fuel cells, a review. Sci. Total Environ. 2021, 763, 143021. [Google Scholar] [CrossRef] [Scilit]
- Lefebvre, O.; Tan, Z.; Kharkwal, S.; Ng, H.Y. Effect of increasing anodic NaCl concentration on microbial fuel cell performance. Bioresour. Technol. 2012, 112, 336–340. [Google Scholar] [CrossRef] [Scilit]
- Meylani, V.; Surahman, E.; Fudholi, A.; Almalki, W.H.; Ilyas, N.; Sayyed, R.Z. Biodiversity in microbial fuel cells: Review of a promising technology for wastewater treatment. J. Environ. Chem. Eng. 2023, 11, 109503. [Google Scholar] [CrossRef] [Scilit]
- Miyahara, M.; Kouzuma, A.; Watanabe, K. Effects of NaCl concentration on anode microbes in microbial fuel cells. AMB Express 2015, 5, 34. [Google Scholar] [CrossRef] [Scilit]
- Hernández-Flores, G.; Solorza-Feria, O.; Poggi-Varaldo, H.M. Bioelectricity generation from wastewater and actual landfill leachates: A multivariate analysis using principal component analysis. Int. J. Hydrogen Energy 2017, 42, 20772–20782. [Google Scholar] [CrossRef] [Scilit]
- Slate, A.J.; Whitehead, K.A.; Brownson, D.A.C.; Banks, C.E. Microbial fuel cells: An overview of current technology. Renew. Sust. Energ. Rev. 2019, 101, 60–81. [Google Scholar] [CrossRef] [Scilit]
- Ren, Y.; Chen, J.; Li, X.; Yang, N.; Wang, X. Enhanced bioelectricity generation of air-cathode buffer-free microbial fuel cells through short-term anolyte pH adjustment. Bioelectrochemistry 2018, 120, 145–149. [Google Scholar] [CrossRef] [Scilit]
- Samsudeen, N.; Radhakrishnan, T.K.; Matheswaran, M. Bioelectricity production from microbial fuel cell using mixed bacterial culture isolated from distillery wastewater. Bioresour. Technol. 2015, 195, 242–247. [Google Scholar] [CrossRef] [Scilit]
- Zhuang, L.; Zhou, S.; Li, Y.; Yuan, Y. Enhanced performance of air-cathode two-chamber microbial fuel cells with high-pH anode and low-pH cathode. Bioresour. Technol. 2010, 101, 3514–3519. [Google Scholar] [CrossRef] [Scilit]
- Fornero, J.J.; Rosenbaum, M.; Cotta, M.A.; Angenent, L.T. Carbon dioxide addition to microbial fuel cell cathodes maintains sustainable catholyte pH and improves anolyte pH, alkalinity, and conductivity. Environ. Sci. Technol. 2010, 44, 2728–2734. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Oliveira, V.B.; Simões, M.; Melo, L.F.; Pinto, A.M.F.R. Overview on the developments of microbial fuel cells. Biochem. Eng. J. 2013, 73, 53–64. [Google Scholar] [CrossRef] [Scilit]
- Guo, F.; Fu, G.; Zhang, Z.; Zhang, C. Mustard tuber wastewater treatment and simultaneous electricity generation using microbial fuel cells. Bioresour. Technol. 2013, 136, 425–430. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Freguia, S.; Rabaey, K.; Yuan, Z.; Keller, J. Sequential anode-cathode configuration improves cathodic oxygen reduction and effluent quality of microbial fuel cells. Water Res. 2008, 42, 1387–1396. [Google Scholar] [CrossRef] [Scilit]
- Iida, Y.; Takatani, Y.; Kojima, A.; Ishii, M. Global trends of ocean CO2 sink and ocean acidification: An observation-based reconstruction of surface ocean inorganic carbon variables. J. Oceanogr. 2021, 77, 323–358. [Google Scholar] [CrossRef] [Scilit]
- Zhang, P.Y.; Liu, Z.L. Experimental study of the microbial fuel cell internal resistance. J. Power Sources 2010, 195, 8013–8018. [Google Scholar] [CrossRef] [Scilit]
- González Del Campo, A.; Cañizares, P.; Lobato, J.; Rodrigo, M.; Fernandez Morales, F.J. Effects of external resistance on microbial fuel cell’s performance. In The Handbook of Environmental Chemistry; Springer: Cham, Switzerland, 2014; Volume 34, pp. 175–197. [Google Scholar]
- Liu, T.; Yu, Y.Y.; Li, D.; Song, H.; Yan, X.; Chen, W.N. The effect of external resistance on biofilm formation and internal resistance in Shewanella inoculated microbial fuel cells. RSC Adv. 2016, 6, 20317–20323. [Google Scholar] [CrossRef] [Scilit]
- Potrykus, S.; León-Fernández, L.F.; Nieznański, J.; Karkosiński, D.; Fernandez-Morales, F.J. The influence of external load on the performance of microbial fuel cells. Energies 2021, 14, 612. [Google Scholar] [CrossRef] [Scilit]
- Szewczyk, A.; Sikula, J.; Sedlakova, V.; Majzner, J.; Sedlak, P.; Kuparowitz, T. Voltage dependence of supercapacitor capacitance. Metrol. Meas. Sys. 2016, 23, 403–411. [Google Scholar] [CrossRef] [Scilit]
- Ishii, S.; Watanabe, K.; Yabuki, S.; Logan, B.E.; Sekiguchi, Y. Comparison of Electrode Reduction Activities of Geobacter sulfurreducens and an Enriched Consortium in an Air-Cathode Microbial Fuel Cell. Appl. Environ. Microbiol. 2008, 74, 7348–7355. [Google Scholar] [CrossRef] [Scilit]
- He, H.; Sun, B.; Sun, X.; Wang, Z. Experimental and theoretical study on water solubility of carbon dioxide in oil and gas displacement. J. Pet. Sci. Eng. 2021, 203, 108685. [Google Scholar] [CrossRef] [Scilit]
- Fan, Y.; Sharbrough, E.; Liu, H. Quantification of the internal resistance distribution of microbial fuel cells. Environ. Sci. Technol. 2008, 42, 8101–8107. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.