When Intraocular Pressure Control Is Not Disease Control: Glaucoma Progression Despite Apparently Adequate Intraocular Pressure

,
,
,
,
,
,
,
,
…
1
Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 9DU, UK
2
Department of Translational Biomedicine and Neuroscience, University of Bari “Aldo Moro”, 70124 Bari, Italy
3
Eye Unit, “Luigi Curto” Hospital, Azienda Sanitaria Locale Salerno, 84035 Polla, Italy
4
Department of Medicine, Surgery and Dentistry, “Scuola Medica Salernitana”, University of Salerno, 84081 Baronissi, Italy

Abstract

Progressive glaucomatous optic neuropathy despite apparently adequate intraocular pressure (IOP) represents a clinically important discordance between numerical target attainment and disease behavior. This review examines how that discordance should be interpreted and managed. Before concluding that a low target is biologically insufficient, progression should be confirmed and the apparent pressure state interrogated, as office IOP may incompletely represent the exposure experienced by the eye because of measurement uncertainty, variable treatment implementation, and sparse temporal sampling. When progression remains convincing despite apparently low pressure exposure, the discordance may reflect individual susceptibility to pressure-related injury, potentially modified by optic-nerve-head biomechanics, disk hemorrhage, ocular phenotype, and systemic haemodynamics. These factors may operate through distinct and interacting pathways, although current evidence supports their prognostic relevance more strongly than their use as therapeutic targets. Importantly, progression at low IOP does not imply exhaustion of pressure-mediated benefit; evidence from selected low-pressure surgical cohorts and a recent meta-analysis suggests that further lowering may slow subsequent deterioration, albeit with increasing treatment morbidity. We therefore organize the available evidence into a sequential clinical framework encompassing verification of the progression signal, characterization of pressure exposure, contextualization of optic-nerve susceptibility, and reassessment of the pressure target. Numerical target attainment and longitudinal target adequacy are not synonymous: the former describes achievement of a prespecified pressure goal, whereas the latter can only be judged against the subsequent structural and functional trajectory. The clinically relevant endpoint is therefore not attainment of an IOP number itself, but preservation of an acceptable disease trajectory for the individual eye.

1. Introduction

Intraocular pressure (IOP) is the only modifiable risk factor for which treatment has consistently been shown to alter glaucoma progression. Randomized trials have established benefit across primary open-angle and normal-tension glaucoma, and contemporary management therefore uses an individualized target IOP intended to preserve useful vision over the patient’s lifetime [1,2,3,4]. The target is inherently dynamic: its adequacy depends on baseline damage, untreated IOP, observed rate of progression, life expectancy, treatment burden, and subsequent structural and functional behavior. Yet treatment does not eliminate progression. Visual-field deterioration occurred in 15.2% of latanoprost-treated UKGTS participants within 2 years, in 45% of treated EMGT participants over a median of 6 years, and in approximately 12% of CNTGS eyes in the analysis based on eyes achieving the intended pressure reduction, although interpretation of CNTGS is complicated by differences from the intention-to-treat analysis and cataract-related visual-field effects [1,2,3]. These observations do not establish that pressure exposure was adequately controlled in individual progressors, but they illustrate the clinical distinction between treatment response, numerical target attainment, and longitudinal disease control.
Apparent target attainment is therefore an ambiguous clinical state. The progression signal itself may be unreliable; office IOP may be affected by measurement uncertainty or may be obtained during a pharmacological state that does not reflect usual treatment implementation; sparse sampling may miss relevant pressure exposure outside clinic; and eyes with apparently low exposure may differ in ocular or systemic susceptibility [5,6,7,8,9,10,11,12,13]. Progression despite an apparently satisfactory clinic IOP therefore does not identify a single mechanism, nor does it automatically establish that the selected target is biologically insufficient. These explanations can be integrated within a common clinical construct: glaucomatous progression reflects the interaction between pressure exposure and individual optic-nerve susceptibility, as manifested by the subsequent structural and functional trajectory. While office IOP provides an incomplete representation of pressure exposure [7,8,9], biomechanical characteristics [10,11], disk hemorrhage [14,15,16], and systemic haemodynamics [12,13] may modify or signal vulnerability to a given pressure state. These factors should not be interpreted as manifestations of a single established causal pathway; rather, their consideration provides a coherent clinical basis for investigating why numerical target attainment may coexist with continued disease progression.
Several components of this clinical problem have been addressed previously. Previous reviews have challenged fixed or formulaic approaches to target IOP, examined target setting in the context of 24 h monitoring, and addressed the management of glaucoma progressing at low or normal IOP [17,18,19,20]. More recently, real-world longitudinal data have linked failure to achieve clinician-set targets with faster visual-field worsening, while a contemporary editorial has argued that disease progression, rather than the clinic IOP value itself, should guide treatment escalation [21,22]. Taken together, these contributions support a dynamic view of target IOP, but do not provide a unified framework for interpreting the clinical significance of progression after apparent target attainment. Accordingly, the present review is not intended as another review of low IOP or target-setting formulas per se. It focuses on the diagnostic interpretation of discordance between numerical target attainment and subsequent disease behavior.
This review integrates these explanations into a sequential framework for assessing glaucoma progression despite apparently adequate IOP. Its purpose is to operationalize the distinction between numerical target attainment and longitudinal target adequacy, while recognizing that the proposed framework is a clinical reasoning construct rather than a validated treatment algorithm.

Literature Search and Evidence Synthesis

This article was designed as a critical narrative review rather than a systematic review or meta-analysis. Targeted PubMed/MEDLINE searches were performed and updated through August 2026, supplemented by citation chaining from major randomized trials, longitudinal cohorts, systematic reviews, and glaucoma guidelines. Searches were organized around five prespecified domains relevant to progression despite apparently adequate intraocular pressure (IOP): (1) confirmation and rate of structural or functional progression; (2) accuracy and temporal representativeness of IOP measurement; (3) treatment implementation and adherence; (4) ocular and systemic susceptibility; and (5) outcomes of additional IOP lowering in eyes progressing at low baseline pressure. Search concepts included combinations of glaucoma, progression, target IOP, normal-tension glaucoma, home tonometry, 24 h IOP, IOP fluctuation, adherence, corneal hysteresis, disk hemorrhage, ocular perfusion pressure, nocturnal hypotension, trabeculectomy, glaucoma drainage devices, selective laser trabeculoplasty, and minimally invasive glaucoma surgery.
Evidence was selected according to relevance to the clinical question and its ability to inform mechanism, prognosis, or treatment. Randomized trials and longitudinal studies with structural or functional progression endpoints were prioritized when available; prospective monitoring studies were used to characterize out-of-office pressure exposure and haemodynamics; and retrospective surgical series were retained when they addressed very low pressure ranges not represented in randomized trials. Systematic reviews and guidelines were used principally to assess consistency and clinical applicability. Because populations, pressure metrics, progression definitions, and interventions were heterogeneous, no pooled quantitative synthesis was undertaken. Study design and major evidential limitations are therefore reported alongside key findings in the text and Table 1. No formal risk-of-bias grading was performed, and the review should be interpreted as a critical synthesis rather than an exhaustive systematic inventory. Focused systematic reviews and meta-analyses using prespecified, sufficiently comparable definitions of progression could complement this framework by addressing narrower questions about individual risk factors or treatment effects.
Table 1. Evidence map and clinical implications for reassessing apparently controlled intraocular pressure.

2. Before Calling IOP ‘Controlled’: Verify the Signal

The first question is deliberately narrow: is the eye truly progressing? This step should remain brief but rigorous because every subsequent inference—occult pressure exposure, increased susceptibility, or target inadequacy—depends on it. Perimetric event analysis is vulnerable to false-positive alerts when isolated from longitudinal context. Wu and Medeiros estimated a 5-year cumulative false-positive rate of approximately 34% for Guided Progression Analysis (GPA) ‘possible progression’, compared with approximately 7% for ‘likely progression’ [23]. A single alert may therefore provide insufficient specificity for a major target reset, particularly when the therapeutic consequence could be filtration surgery.
Trend analysis becomes increasingly informative once sufficient examinations are available because it estimates the velocity of loss rather than simply whether an event has occurred. The clinically relevant distinction is therefore not only progressor versus non-progressor, but whether the observed rate is likely to consume useful visual reserve during the patient’s lifetime [36]. The confidence interval around the estimated slope also matters: a steep rate derived from few tests is less secure than the same rate sustained over years, although waiting for statistical certainty may be inappropriate when deterioration is advanced or threatens fixation.
Structural and functional evidence should be integrated rather than required to progress synchronously. Longitudinal retinal nerve fiber layer (RNFL) change may precede detectable field deterioration, and structural and functional endpoints frequently identify progression at different visits [24,25]. In advanced disease, RNFL measurements approach a floor while small additional functional losses may remain clinically important. Central disease also deserves specific attention because a modest global 24-2 mean deviation may coexist with clinically relevant paracentral deterioration detectable on 10-2 testing [28,37]. Progression should therefore be reproducible, anatomically coherent, and characterized by rate and location rather than by a binary software flag alone.
Media opacity, particularly progressive cataract, should also be considered when interpreting longitudinal visual-field deterioration. Cataract-related generalized sensitivity loss may worsen global perimetric indices without indicating glaucomatous progression. Rao et al. demonstrated that mean deviation improved significantly after cataract extraction in glaucomatous eyes, whereas the visual field index remained relatively stable, highlighting the differential susceptibility of perimetric indices to lens opacity [38]. Clinical assessment should therefore consider changes in lens opacity, the spatial pattern and repeatability of field loss, and concordance with structural findings. Where cataract substantially confounds interpretation, postoperative reassessment may be necessary to establish a reliable functional baseline.
Once progression is sufficiently credible, the central problem of this review begins. The question is no longer whether glaucoma is worsening, but why deterioration is occurring when the recorded IOP appears acceptable. At that point, ‘controlled IOP’ can be separated into three testable propositions: the measurement is technically credible; the sampled values adequately represent pressure exposure between visits; and that exposure is sufficiently low for the individual optic nerve.

3. Is the Measured IOP Credible?

Goldmann applanation tonometry (GAT) remains the clinical reference standard, but its precision is finite even before biological variability is considered. Under ideal conditions, reported 95% limits for intra-observer and inter-observer variability are approximately 2.5 and 4.0 mmHg, respectively; in one same-slit-lamp comparison, two physicians differed by >2 mmHg in 17% of patients [5]. At the low end of the pressure distribution, this is not trivial: a measured 11 mmHg and a measured 14 mmHg can imply very different therapeutic pathways in a rapidly progressing eye. Corneal properties add systematic error. In simultaneous manometry-tonometry experiments, thin corneas underestimated intracameral pressure by as much as 4.9 mmHg and thick corneas overestimated it by up to 6.8 mmHg; published central corneal thickness (CCT) effects range from approximately 0.11 to 0.71 mmHg per 10 µm difference in thickness [5]. These extreme observed discrepancies illustrate measurement uncertainty rather than predictable CCT-dependent correction factors and should not be converted into a universal correction formula, because thickness is only one component of corneal biomechanics. A more cautious practical implication is: when progression appears discordant with a low GAT value, measurement uncertainty of several mmHg is biologically large enough to deserve explicit consideration.
Alternative tonometers do not solve the problem by revealing a single ‘true IOP’. In the UKGTS risk-factor analysis, visit-1 mean IOP was 16.3 versus 17.4 mmHg by GAT in non-progressors and progressors, 19.9 versus 22.3 mmHg by ocular response analyzer, and 18.3 versus 19.3 mmHg by dynamic contour tonometry; each measure was associated with deterioration in univariable analysis [14]. The absolute values were not interchangeable. Corneal hysteresis (CH) should therefore be treated as a susceptibility marker rather than an arithmetic pressure correction: CH averaged 9.2 ± 2.0 mmHg in non-progressors versus 8.6 ± 1.7 mmHg in progressors (HR 0.86 per 1-mmHg higher CH, 95% CI 0.77–0.96; p = 0.008), whereas central corneal thickness was not significantly associated with deterioration in that analysis [14].
A clinic IOP is also a time-stamped observation. Time since waking, recent topical dosing, recent systemic medication, posture, stress, and measurement sequence can influence the value obtained. These effects are usually modest compared with the differences required for major treatment decisions, but they become important when a patient repeatedly sits just below a target and continues to progress. The correct response is not to chase decimal precision; it is to ask whether the available measurements are sufficiently representative to justify the claim of control [5,19].

4. Is the Prescribed Treatment the Treatment the Eye Actually Receives?

Prescription and pharmacological exposure should not be assumed to be synonymous. Kumar et al. [6] electronically monitored 137 treated glaucoma patients for approximately 3 months. Despite 81% of participants reporting that they were ‘very confident’ they always remembered their drops, electronically verified implementation was substantially less uniform; among patients stratified by pharmacy medication-possession ratio, only 59% and 63% in the two lower refill groups took at least 80% of prescribed doses, compared with 88% in the highest refill group. Self-report alone may therefore be insufficient to establish the pharmacological state under which an office IOP was obtained. This matters because the clinician usually interprets the measured pressure as if the prescribed regimen had been delivered consistently in the preceding days and weeks.
The problem is amplified by visit-related behavior. Poleon et al. documented a ‘white-coat adherence’ effect in which implementation improves around clinic encounters [26]. A reassuring office pressure may therefore be obtained during a period of better-than-usual dosing. Conversely, a high clinic pressure in a reliably treated patient has a different meaning from the same pressure in a patient with intermittent exposure. Treatment escalation should, where possible, distinguish these states because increasing regimen complexity can worsen implementation rather than improve it.
Adherence may have clinically relevant associations with functional outcome and should not be considered solely a behavioral nuisance. In a large real-world cohort, Shu et al. [27] found that each 10% absolute increase in medication adherence was associated with a 0.006 dB/year reduction in the rate of MD deterioration (p = 0.006). Modeled annual MD change was −0.37 dB/year at 20% adherence versus −0.32 dB/year at 80% adherence; for moderate baseline disease, the model delayed a 3 dB deterioration by approximately 1 year at the higher adherence level. The effect size is modest, but the inference is clinically important: an apparently satisfactory IOP obtained during intermittent or visit-enhanced dosing may not represent the pressure exposure that generated the observed visual-field trajectory. Before declaring a low target biologically insufficient, clinicians should therefore consider distinguishing pharmacological failure from implementation failure and, where appropriate, simplify treatment, address tolerability and technique, or use adherence-independent strategies such as selective laser trabeculoplasty (SLT) or surgery.

5. Office IOP Versus Pressure Exposure Beyond Office Sampling

5.1. Home and 24 h Tonometry

IOP varies over hours and days, whereas routine care samples it at a small number of daytime visits. The resulting mismatch may be clinically relevant. Hughes et al. found that 24 h peak IOP was on average 4.9 mmHg higher than the highest clinic measurement, with more than half of peaks occurring outside office hours; additional monitoring altered management in 79.3% of selected patients [7]. Barkana et al. likewise showed that measurements outside routine office hours can reveal information that changes the interpretation of control [39]. These studies were performed in selected populations and do not justify routine 24 h phasing, but they support the principle that repeated low daytime values do not necessarily establish low exposure across the full circadian cycle.
Home rebound tonometry makes repeated measurements possible in the habitual environment and has produced some of the most directly relevant evidence for the apparently controlled progressor. Cvenkel and Atanasovska Velkovska studied eyes with controlled office IOP and found that progressors had higher home mean IOP (15.8 vs. 13.3 mmHg), peak IOP (21.8 vs. 18.6 mmHg), and peak-to-trough range (11.6 vs. 9.1 mmHg) than stable eyes [8]. This finding is relevant because the groups appeared similar under conventional clinic sampling yet separated when exposure was measured more densely.
McGlumphy et al. [9] similarly showed that denser sampling can materially change the interpretation of pressure control. Mean daily maximum home IOP exceeded the recent clinic maximum in 44% of patients and any historical charted maximum in 13%; among eyes with a documented target, 74% recorded at least one home value above target compared with 61% in clinic (p < 0.001), and peak IOP occurred outside 08:00–17:00 on 50% of monitored days. Following home monitoring, treatment was advanced in 55 of 95 eyes (58%). Scott et al. likewise showed that home tonometry can detect treatment-related pressure changes across different periods of the day, but used pressure response rather than structural or functional progression as the endpoint [40].
The clinical value of home tonometry therefore lies primarily in identifying pressure exposure that routine office measurements may miss, rather than in applying a validated home-derived threshold for treatment escalation. The relative prognostic importance of mean, peak, and fluctuating IOP remains uncertain [8,9].

5.2. IOP Fluctuation

The literature on IOP fluctuation is heterogeneous because ‘fluctuation’ describes different constructs. Short-term diurnal range, day-to-day variability, and long-term visit-to-visit standard deviation are not interchangeable. In the Early Manifest Glaucoma Trial (EMGT), 255 patients were followed for a median of 8 years; long-term fluctuation was not independently associated with progression after mean IOP was included in time-dependent models [41]. By contrast, an Advanced Glaucoma Intervention Study (AGIS)-derived analysis reported an approximately 40% increase in the odds of progression for each 1-mmHg increase in long-term IOP standard deviation, with the association most evident in the lowest mean-IOP tercile (approximately 10.8 mmHg) [42]. In an earlier home-tonometry cohort of 64 patients (105 eyes), the 5-day diurnal IOP range was associated with progression after adjustment for office IOP and baseline covariates (relative hazard 5.69, 95% CI 1.86–17.35); 88% of eyes in the upper quartile of IOP range versus 57% in the lower quartile progressed within 8 years [43]. These findings suggest that variability may carry prognostic information in selected phenotypes, but they do not establish a universal fluctuation threshold or prove that fluctuation itself is causal.
Interaction may be more informative than a main effect. Lee et al. found that long-term IOP fluctuation was associated with faster MD and Visual Field Index (VFI) deterioration in myopic normal-tension glaucoma (NTG) but not in non-myopic NTG, with a significant interaction between myopia and fluctuation [44]. Such findings caution against treating variability as a single universal target and support interpreting pressure dynamics within the phenotype of the eye.

5.3. Continuous Monitoring

Contact-lens sensors provide dense 24 h IOP-related profiles, but current devices measure ocular dimensional change in electrical units rather than calibrated IOP in mmHg. Cross-sectional and longitudinal studies have associated derived signal features with glaucoma severity or progression [45,46,47]. Higashide et al. provided prospective evidence in NTG that baseline 24 h profile characteristics, including greater diurnal IOP range, were associated with subsequent progression [48].
These results are promising but not yet sufficient for routine target setting. Signal-processing approaches differ between studies, external validation is limited, and a derived electrical feature cannot currently be translated into an individualized pressure threshold. At present, a defensible clinical role for extended monitoring is hypothesis testing: when disease behavior is inconsistent with clinic IOP, denser sampling can determine whether the apparent paradox is partly a sampling problem [47,48].
The clinical implications of these evidence domains are summarized in Table 1.

6. When Available Evidence Suggests Low Pressure Exposure: Biological Susceptibility

6.1. Ocular Biomechanical Susceptibility

If progression is genuine and extended assessment provides no convincing evidence that office sampling materially underestimates pressure exposure, the relevant question changes from ‘what pressure was measured?’ to ‘what does that pressure do to this eye?’. The optic nerve head is a mechanically heterogeneous load-bearing structure: experimental and computational biomechanical studies indicate that IOP-related stress and strain depend not only on pressure magnitude but also on lamina cribrosa architecture, scleral canal geometry, peripapillary scleral stiffness, and other tissue properties [49,50]. Consequently, an identical IOP may produce different mechanical responses across eyes. This provides a mechanistic rationale for considering individual susceptibility to pressure-related injury, even at relatively low IOP, but does not establish that biomechanical differences are the cause of progression in any given patient.
In vivo imaging supports biological relevance but remains short of a clinical calculator. Longitudinal studies summarized by Downs and Girkin associate aspects of lamina cribrosa position and deformation with RNFL behavior, including slower RNFL loss in eyes showing maintained anteriorization after trabeculectomy [50]. Yet current measurements cannot determine the pressure at which an individual lamina will remain stable. Posterior ocular biomechanics is therefore mechanistically mature but therapeutically immature.
Among clinically accessible biomechanical measures, CH has some of the most consistent longitudinal evidence as a susceptibility marker. Medeiros et al. showed prospectively that lower CH was associated with faster visual-field decline and modified the relationship between IOP and progression [10]. The phenotype most relevant to this review was examined by Susanna et al. [11]: among 179 eyes in which every recorded IOP was <18 mmHg, 42 (23.5%) progressed. Progressors and stable eyes had similar mean IOP (11.7 ± 2.0 vs. 12.1 ± 2.3 mmHg; p = 0.405), peak IOP (14.3 ± 1.9 vs. 14.6 ± 2.1 mmHg; p = 0.926), and office IOP fluctuation (1.6 ± 0.6 vs. 1.6 ± 0.5 mmHg; p = 0.402), but progressors had lower CH (8.6 ± 1.3 vs. 9.4 ± 1.6 mmHg; p = 0.014) and thinner central corneal thickness (515.1 ± 33.1 vs. 531.1 ± 42.4 µm; p = 0.018). The study therefore supports biomechanical phenotype as a prognostic correlate when conventional office IOP metrics appear similar, without providing a CH-specific treatment threshold.
Kamalipour et al. [28] extended the prognostic signal to central function in 248 eyes followed for a mean of 4.8 years. Eyes with baseline CH < 10 mmHg deteriorated on 10-2 testing approximately 0.15 dB/year faster than eyes with CH ≥ 10 mmHg (p = 0.008), with regional differences reaching approximately −0.28 dB/year in the most affected zones. The available evidence therefore supports interpreting CH primarily as a prognostic rather than tonometric measure: it does not tell us that an IOP of 14 mmHg is ‘really’ 16 mmHg; it tells us that two eyes exposed to the same measured pressure may not share the same probability of central functional stability. No trial has yet established a CH-specific target IOP or shown that CH-guided escalation improves outcome.

6.2. Disk Hemorrhage and Phenotype-Specific Vulnerability

Disk hemorrhage has repeatedly been associated with progression and may be clinically informative in the apparently controlled progressor. In UKGTS, disk hemorrhage at the first post-randomization visit was present in 39 participants; 33.3% of these deteriorated versus 19.2% without hemorrhage, with an unadjusted HR of 1.87 and an adjusted HR of 2.08 (95% CI 1.07–4.04; p = 0.030) [14]. In a separate treated-glaucoma cohort of 587 eyes followed for a mean of 6.4 years, detected disk hemorrhage was independently associated with visual-field progression (odds ratio (OR) 2.59; p < 0.01), alongside peak IOP (OR 1.13 per mmHg), thinner CCT (OR 1.45 per 40 µm thinner), and beta-zone parapapillary atrophy (OR 2.38) [15]. Disk hemorrhage should therefore not be interpreted as evidence of pressure-independent disease; rather, its presence may identify an eye at higher risk despite the current pressure state.
Myopia provides an example of phenotype-dependent susceptibility, as discussed in Section 5.2. This interaction-based perspective may help explain heterogeneity in progression risk at similar measured IOP levels, although its clinical utility for defining treatment subtypes remains to be prospectively validated.
Baek et al. [16] provide a useful integrated model of susceptibility in low-teens NTG. Among 102 eyes with untreated IOP ≤ 12 mmHg, 36 (35.3%) progressed during long-term follow-up. Pretreatment office IOP, medicated follow-up IOP, percentage IOP reduction, and follow-up IOP fluctuation were not significant predictors. In the multivariable Cox model, greater diurnal IOP fluctuation was associated with progression (HR 1.609 per 1-mmHg increase; 95% CI 1.168–2.216; p = 0.004), as was greater diastolic blood-pressure fluctuation (HR 1.058; 95% CI 1.020–1.097; p = 0.002) and disk hemorrhage (HR 3.664; p = 0.001). These observational data support heterogeneity within the low-office-IOP progressor phenotype rather than a single pressure-independent explanation.
Genetic susceptibility may provide an additional dimension of risk stratification beyond clinically observable ocular phenotypes. Polygenic risk scores (PRSs), which aggregate the effects of numerous glaucoma-associated genetic variants, have been associated with disease severity and progression. Craig et al. demonstrated that a glaucoma PRS predicted progression in prospectively monitored early glaucoma [51]. More directly, Siggs et al. reported that individuals in the highest 5% of the PRS distribution had a greater risk of visual-field progression over five years than the remaining 95% (HR 1.50, 95% CI 1.13–1.97), despite more intensive treatment [52]. These findings suggest that genetic risk may help identify eyes requiring closer surveillance. However, current glaucoma PRSs do not specifically quantify optic-nerve-head biomechanical properties, distinguish pressure-dependent from pressure-independent susceptibility, or provide validated thresholds for treatment escalation. Their role in managing patients who progress despite apparently adequate IOP therefore remains investigational.

7. Systemic Haemodynamics: Modifier, Not Substitute

Systemic haemodynamics may modify the relationship between IOP and glaucomatous damage, particularly in low-pressure phenotypes, but the evidence is stronger for prognostic association than for treatment guidance. In the Low-pressure Glaucoma Treatment Study (LoGTS), lower mean ocular perfusion pressure was associated with visual-field progression, although calculated perfusion pressure remains an indirect construct derived from brachial blood pressure and IOP rather than a direct measure of optic-nerve-head perfusion [53].
Prospective ambulatory monitoring provides more complete characterization of systemic pressure exposure. Charlson et al. [12] followed 85 patients with normal-tension glaucoma (166 eyes) using 48 h ambulatory blood-pressure monitoring. Greater cumulative sleep time with mean arterial pressure at least 10 mmHg below daytime mean independently predicted subsequent visual-field progression (p < 0.02), whereas follow-up IOP was not predictive in that analysis (p = 0.37). The finding implicated the duration and magnitude of nocturnal hypotensive exposure, but brachial blood pressure remains a surrogate for ocular perfusion.
More recent prospective evidence has linked 24 h systemic pressure to the rate of functional loss. In the Vascular Imaging in Glaucoma Study, Donkor et al. [29] evaluated 124 eyes of 64 participants (91 with glaucoma and 33 glaucoma suspects) over 28.3 ± 6.0 months. After multivariable adjustment, each 10-mmHg lower 24 h average mean arterial pressure was associated with an additional −0.171 dB/year of mean-deviation loss (p = 0.045), and each 10-mmHg lower average systolic pressure with −0.137 dB/year faster loss (p = 0.023). Inclusion of suspects, relatively short follow-up, and the observational design limit causal inference; the study strengthens prognostic association without showing that blood-pressure modification improves glaucoma outcomes.
Haemodynamic associations should not be translated directly into intervention. In LoGTS, systemic antihypertensive use was associated with progression (adjusted HR 2.53, 95% CI 1.32–4.87), but dose, timing, duration, and 24 h blood-pressure behavior were not characterized [53]. The association may therefore reflect vascular comorbidity, treatment-related hypotension, or residual confounding. Larger observational studies further complicate the interpretation of systemic blood-pressure associations. In the PROGRESSA cohort, comprising 1314 participants (2628 eyes), systemic hypertension was associated with both OCT-defined structural progression (OR 1.79, 95% CI 1.17–2.75) and visual-field progression (OR 1.92, 95% CI 1.18–3.15). Importantly, antihypertensive medication use was also associated with longitudinal structural progression (OR 1.83, 95% CI 1.19–2.08; p = 0.005) and visual-field progression (OR 1.91, 95% CI 1.16–3.13; p = 0.010) [30].
Antihypertensive treatment was additionally associated with predominantly macular ganglion cell–inner plexiform layer thinning at baseline (OR 2.03, 95% CI 1.20–3.46). These observational associations should not be interpreted as evidence that antihypertensive treatment causes glaucoma progression, as confounding by indication, underlying hypertension, cardiovascular comorbidity, and treatment-related haemodynamic changes cannot be reliably disentangled [30].
In the Duke Glaucoma Registry, involving 7501 eyes, lower mean arterial and diastolic pressures were associated with faster longitudinal RNFL thinning after adjustment for IOP and other covariates [31]. Population-based UK Biobank data additionally associated calcium-channel blocker use with thinner macular ganglion cell–inner plexiform and retinal nerve fiber layers, although this cross-sectional analysis did not establish progressive loss [32]. Importantly, antihypertensive prescriptions may reflect underlying hypertension, cardiovascular comorbidity, medication-class effects, or treatment-related hypotension. These observational associations cannot disentangle these mechanisms or establish that modifying antihypertensive therapy improves glaucoma outcomes.
A systematic review likewise found associations involving low or high blood pressure, nocturnal dipping, and 24 h variability, while emphasizing heterogeneity and the lack of evidence that haemodynamic intervention alters glaucoma outcomes [13].
Ambulatory blood-pressure monitoring may therefore be informative in selected patients with convincing progression at apparently low IOP when excessive nocturnal dipping, symptomatic hypotension, or treatment-related hypotensive exposure is plausible [12,13,29]. These data do not support routine monitoring in all glaucoma patients or unilateral withdrawal or retiming of antihypertensive therapy by the ophthalmologist. Systemic haemodynamics are best regarded as modifiers of pressure tolerance and risk stratification; IOP lowering remains the glaucoma intervention supported by the strongest interventional evidence.

8. Reassessing the Target: From a Number to a Longitudinal Hypothesis

Once progression is credible and apparent pressure control has been reasonably verified, the existing target should be reconsidered in relation to the subsequent disease trajectory. Within this review, target attainment denotes achievement of the prespecified numerical IOP goal; longitudinal target adequacy denotes an observed structural and functional trajectory judged acceptable for the individual eye. The latter remains a clinical judgment rather than a directly measurable biological state or validated endpoint [4].
No universal formula defines the revised target. Age is a major non-modifiable determinant of glaucoma risk and progression, although its implications for treatment must be interpreted alongside remaining life expectancy and visual reserve. In the Early Manifest Glaucoma Trial, older age was independently associated with a greater risk of progression [54]. Importantly, chronological age alone should not determine treatment intensity: a younger patient with moderate progression may accumulate substantial lifetime visual disability, whereas an older patient with advanced disease and deterioration threatening fixation may require urgent escalation despite a shorter remaining lifespan. The required IOP reduction should therefore reflect the rate and location of loss, disease stage, visual reserve, age, life expectancy, previous untreated and treated pressure, treatment burden, and the morbidity of the intervention needed to achieve further lowering [4,22]. The relevant endpoint is not necessarily zero measurable change, but a trajectory unlikely to cause meaningful visual disability within the patient’s lifetime.
Low-pressure glaucoma illustrates why percentage reduction and absolute pressure must be interpreted together: a 30% reduction from 30 mmHg and from 15 mmHg produces fundamentally different final pressure states. CNTGS established that additional IOP lowering can reduce progression risk even when baseline IOP lies within the statistically normal range, while selected surgical cohorts suggest that some eyes progressing in the low teens may slow after pressures near 10 mmHg or below are achieved [2,33,34,35]. These observational data do not establish a universal threshold, but support reconsidering the absolute pressure goal when the disease trajectory remains unacceptable despite achieving the original percentage reduction [2,4].
A dynamic target does not imply escalation after every statistically significant change. Treatment burden, ocular-surface disease, surgical morbidity, fellow-eye status, patient preference, and expected lifetime benefit remain part of the calculation; a biologically ambitious target that cannot be achieved safely or sustained in practice is not necessarily clinically superior [4].

9. Treatment: Matching Therapy to the Required Pressure State

9.1. Modest Additional Lowering: Medical Therapy and SLT

If the revised target requires only modest additional lowering, medication optimization or selective laser trabeculoplasty (SLT) may be sufficient. The choice should reflect the mechanism of apparent failure as well as the size of the residual pressure gap. When implementation is unreliable, increasing topical complexity may be less effective than reducing dependence on daily dosing; conversely, intolerance, ocular-surface toxicity, systemic contraindications, and dosing burden can make the theoretical efficacy of a regimen greater than its sustainable real-world effect. Six-year LiGHT data support the durability of an SLT-first strategy, with less progression in the SLT-first than the drops-first pathway and a substantial proportion of initially SLT-treated eyes remaining at or below target without medication or incisional surgery [55]. These data are not specific to low-pressure progressors, but they support SLT when treatment reliability and medication burden are central components of apparent control.

9.2. MIGS When Modest Additional Lowering Is Sufficient

Angle-based minimally invasive glaucoma surgery (MIGS) may be useful when medication burden or treatment reliability is a major component of apparent failure, but its expected absolute pressure reduction should be matched to the revised target. In normal-tension glaucoma, Salimi et al. reported a reduction from 15.8 to 12.3 mmHg after combined phacoemulsification and iStent inject implantation [56]. A 2024 meta-analysis of 15 studies including 367 NTG eyes undergoing combined phacoemulsification and angle-based MIGS found pooled mean IOP reductions of approximately 2.1–2.4 mmHg through 36 months [57]. Importantly, these reductions reflect the combined procedures and should not be attributed exclusively to the MIGS component. Cataract extraction alone can produce a clinically relevant reduction in IOP: in a large matched-cohort study involving 16,169 patient pairs, Carolan et al. found a mean between-group difference in IOP change of 1.21 mmHg (95% CI 1.12–1.30) following phacoemulsification, with smaller reductions generally observed at lower preoperative pressures [58]. Furthermore, an American Academy of Ophthalmology assessment of randomized trials reported an additional IOP reduction of approximately 1.6–2.3 mmHg with trabecular procedures combined with cataract surgery compared with cataract surgery alone in patients with hypertensive, mild-to-moderate open-angle glaucoma, while identifying a lack of level I evidence in eyes with pretreatment IOP ≤ 21 mmHg [59]. These findings cannot be directly extrapolated to progressive NTG, and the incremental benefit of MIGS over phacoemulsification alone in this low-pressure phenotype remains uncertain. Combined phaco-MIGS may therefore be appropriate when modest IOP lowering or medication reduction is sought, but should not be assumed to reliably achieve the near-10 or single-digit pressure state required by some low-pressure progressors.
Accordingly, procedural success and disease-control adequacy should not be treated as equivalent endpoints: a modest reduction may be sufficient when the target reset is small, but medication-free status alone does not establish that the revised pressure requirement has been met [56,57].

9.3. Filtration Surgery for Very-Low Pressure Targets

When the revised target approaches 10 mmHg or single digits, trabeculectomy has the most directly relevant disease-specific evidence in progressive low-pressure NTG. Aoyama et al. followed 40 trabeculectomized Japanese NTG eyes for a mean of 12 years: mean IOP fell from 15.2 to 9.4 mmHg and visual-field progression occurred in 8.3% of eyes with postoperative IOP ≤ 10 mmHg versus 50% above 10 mmHg (p = 0.0068); 2 of 24 eyes nevertheless progressed despite achieving ≤10 mmHg [33]. Because postoperative pressure was achieved rather than randomized, this association cannot establish 10 mmHg as a causal threshold. Iverson et al., in 15 eyes of 14 patients with progressive NTG, reported a reduction in mean IOP from 13.1 ± 1.5 to 8.5 ± 3.5 mmHg. In the 9 eyes with at least 5 preoperative and postoperative fields, mean MD slope improved from −1.05 ± 0.66 to −0.25 ± 0.86 dB/year (p = 0.05), although the small retrospective design and regression-to-the-mean risk limit causal inference [34].
The potential functional benefit must be balanced against a narrower safety margin. In Schultz et al. [35], 30 eyes of 28 patients with progressive NTG and preoperative IOP ≤ 15 mmHg underwent trabeculectomy and were followed for a mean of 50 ± 31 months. At final follow-up, mean IOP decreased from 13.2 ± 1.4 to 8.6 ± 2.9 mmHg and medication burden from 2.5 ± 1.2 to 0.6 ± 1.0 (both p < 0.001). The probability of achieving IOP ≤ 10 mmHg was 68% at 4 years, while hypotony occurred in 9/30 eyes (30%), hypotony maculopathy in 2 eyes (6%), and subsequent cataract extraction in 27% of phakic eyes. These series suggest that further lowering may benefit selected low-pressure progressors, but they also show why single-digit pressure should not be treated as a universal target.
A 2026 systematic review and meta-analysis of nine observational studies including 270 eyes provides a broader synthesis of this low-pressure surgical literature. Mean IOP decreased from 14.77 to 9.82 mmHg, while the pooled visual-field mean-deviation slope improved by 0.59 dB/year (95% CI 0.38–0.80; p < 0.0001) after trabeculectomy-based strategies. Because the included evidence was observational, these findings support an association between achieving very low IOP and slower functional deterioration rather than a universal causal threshold, while reinforcing the need to balance potential benefit against hypotony-related morbidity [60].
Tube surgery remains relevant when previous conjunctival surgery, scarring, or the anticipated complication profile makes trabeculectomy less attractive. Randomized tube-versus-trabeculectomy trials inform comparative safety and efficacy in broader surgical populations: at 5 years in PTVT, mean IOP was 13.4 ± 3.5 mmHg after Baerveldt implantation and 13.0 ± 5.2 mmHg after trabeculectomy, with greater medication use after tube surgery [61,62]. Because PTVT enrolled eyes with baseline IOP ≥ 18 mmHg, these data should not be extrapolated directly to eyes progressing at 12–14 mmHg in which sustained near-10 or single-digit pressure is required. Procedure choice should therefore be individualized to the pressure state needed, previous surgery, conjunctival status, visual reserve, and the consequences of failure or hypotony; disease-specific evidence for very-low-pressure progressors is stronger for trabeculectomy than for tube surgery.

10. A Compact Clinical Framework for the Apparently Controlled Progressor

The evidence synthesized in this review can be integrated into a sequential clinical framework organized around four linked domains: progression signal, pressure exposure, susceptibility, and longitudinal target adequacy (Figure 1). The framework provides a structured approach to interpreting progression despite apparently satisfactory IOP, without implying that its components constitute a prospectively validated treatment algorithm.
Figure 1. Proposed clinical framework for progression despite apparently adequate intraocular pressure. The framework separates verification of the progression signal from assessment of measured pressure, treatment implementation, and pressure exposure beyond office sampling, before placing ocular/systemic susceptibility and target reassessment downstream. It is intended as a clinical reasoning model rather than a validated algorithm; every intervention should be reassessed against the subsequent structural and functional trajectory.
This sequence is intended to reduce premature attribution of progression to non-pressure mechanisms: occult exposure should be considered before low office IOP is accepted as representative, while susceptibility markers refine rather than replace assessment of pressure exposure. Conversely, repeated low measurements should not justify therapeutic inertia when the structural or functional trajectory remains convincingly adverse.
Once the most plausible explanation for apparent control has been identified, management should address the specific source of uncertainty or inadequacy rather than reflexively intensify treatment. As discussed in Section 8, further IOP lowering refers to achieving a revised pressure goal below the previously accepted target, based on the individual disease trajectory and the anticipated benefits and risks of treatment. Table 2 translates these considerations into practical assessment steps and criteria for escalation or reassessment.
Table 2. Practical assessment and management of glaucoma progression despite apparently adequate intraocular pressure.
After any intervention, the achieved IOP and subsequent structural and functional trajectory should be reassessed. Failure to reach the revised pressure goal, or continued clinically consequential progression despite achieving it, should prompt renewed evaluation of pressure exposure, treatment implementation, and the feasibility of further escalation.

11. Evidence Gaps and Research Priorities

Future research should establish which out-of-office IOP metrics provide independent and clinically meaningful prognostic information beyond conventional office measurements. Prospective studies should prespecify candidate measures, including mean IOP, peak IOP, and short-term variability, and evaluate their incremental predictive value after accounting for baseline disease severity, treatment changes, and adherence. Randomized studies would subsequently be needed to determine whether management guided by these metrics improves structural or functional outcomes compared with conventional care.
Evidence for CH extends beyond cross-sectional association: prospective data link lower CH to faster global and central functional deterioration [10,28]. What remains unknown is how that information should alter treatment. No study establishes how much further IOP should be lowered because CH is low, and posterior ocular biomechanics remains even further from an actionable target despite strong mechanistic plausibility [50]. An important remaining transition is from risk prediction to treatment-response prediction.
Nocturnal hypotension and lower 24 h systemic pressure have been associated with subsequent visual-field progression, but current evidence does not demonstrate that modifying systemic blood pressure changes glaucoma outcome [12,13,29]. This is a particularly important evidentiary boundary because cardiovascular treatment cannot be altered on ophthalmic association alone. A meaningful interventional study would require objectively documented adverse haemodynamics, coordinated cardiovascular management, and glaucoma progression—not blood-pressure normalization—as the ophthalmic endpoint.
The strongest randomized surgical trials are designed around IOP, medication burden, reoperation, and complications, whereas the evidence most directly applicable to progressive low-pressure glaucoma derives from smaller selected cohorts evaluating very-low postoperative pressure and, in some studies, longitudinal visual-field outcomes [33,34,35]. Future studies of low-pressure progressors should therefore incorporate structural and functional rates of change alongside conventional surgical endpoints. The clinically important comparison is not simply which procedure lowers IOP most, but which patients gain enough preservation of vision to justify the morbidity required to reach the lower target.
The individual components of the proposed framework are supported to different degrees, but their integrated use has not been tested as a management strategy. A prospective study could enroll eyes with reproducible progression despite apparently adequate office IOP and compare conventional care with a structured pathway that verifies progression and treatment implementation, selectively characterizes pressure exposure beyond office sampling, considers susceptibility and haemodynamics where clinically indicated, and recalibrates the target according to longitudinal disease behavior. Structural and functional rates of change would be more informative primary endpoints than the number of additional abnormalities detected, with treatment burden, adverse events, quality of life, and cost considered as secondary outcomes. Until such evidence is available, the framework should be regarded as an evidence-informed approach to clinical reasoning rather than a validated algorithm.

12. Conclusions

Glaucoma progression despite apparently adequate IOP should be approached as a discordance to be explained rather than as immediate evidence of pressure-independent disease. The progression signal should first be verified, followed by assessment of whether measured IOP is technically credible, pharmacologically representative, and sufficiently representative of pressure exposure beyond office sampling. When convincing progression persists despite apparently low exposure, ocular and systemic susceptibility may refine risk interpretation, although neither currently provides an independently validated therapeutic target.
Continued deterioration should prompt reassessment of the existing target. Further IOP lowering may remain beneficial even from low baseline pressures, but increasingly aggressive targets must be justified by the rate and location of loss, visual reserve, expected lifetime, and treatment morbidity [4,33,34,35,57]. Office IOP is therefore a sampled treatment variable rather than the disease endpoint: numerical target attainment does not establish longitudinal disease control, and the adequacy of a target is ultimately judged against the subsequent structural and functional trajectory.

Author Contributions

Conceptualization, C.M.I. and G.B.; methodology, C.M.I. and G.B.; investigation, C.M.I., G.B., L.V., A.A. and P.V.; writing—original draft preparation, C.M.I.; writing—review and editing, C.M.I., G.B., R.T., G.M., L.V., J.M.-N., A.A., P.V., A.S., S.F. and G.S.; supervision, G.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

No new data were created or analyzed in this study. Data sharing is not applicable to this article.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Heijl, A.; Leske, M.C.; Bengtsson, B.; Hussein, M.; Early Manifest Glaucoma Trial Group. Reduction of intraocular pressure and glaucoma progression: Results from the Early Manifest Glaucoma Trial. Arch. Ophthalmol. 2002, 120, 1268–1279. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Collaborative Normal-Tension Glaucoma Study Group. Comparison of glaucomatous progression between untreated patients with normal-tension glaucoma and patients with therapeutically reduced intraocular pressures. Am. J. Ophthalmol. 1998, 126, 487–497. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Garway-Heath, D.F.; Crabb, D.P.; Bunce, C.; Lascaratos, G.; Amalfitano, F.; Anand, N.; Azuara-Blanco, A.; Bourne, R.R.; Broadway, D.C.; Cunliffe, I.A.; et al. Latanoprost for open-angle glaucoma (UKGTS): A randomised, multicentre, placebo-controlled trial. Lancet 2015, 385, 1295–1304. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. European Glaucoma Society. European Glaucoma Society Terminology and Guidelines for Glaucoma, 6th Edition. Br. J. Ophthalmol. 2025, 109, 1–212. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  5. Asrani, S.G.; McGlumphy, E.J.; Al-Aswad, L.A.; Chaya, C.J.; Lin, S.; Musch, D.C.; Pitha, I.; Robin, A.L.; Wirostko, B.; Johnson, T.V. The relationship between intraocular pressure and glaucoma: An evolving concept. Prog. Retin. Eye Res. 2024, 103, 101303. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Kumar, J.B.; Bosworth, H.B.; Sleath, B.; Woolson, S.; Olsen, M.; Danus, S.; Muir, K.W. Quantifying glaucoma medication adherence: Relationship between self-report, electronic monitoring, and pharmacy refill. J. Ocul. Pharmacol. Ther. 2016, 32, 346–354. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Hughes, E.; Spry, P.; Diamond, J. 24-hour monitoring of intraocular pressure in glaucoma management: A retrospective review. J. Glaucoma 2003, 12, 232–236. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Cvenkel, B.; Velkovska, M.A. Self-monitoring of intraocular pressure using Icare HOME tonometry in clinical practice. Clin. Ophthalmol. 2019, 13, 841–847. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. McGlumphy, E.J.; Mihailovic, A.; Ramulu, P.Y.; Johnson, T.V. Home self-tonometry trials compared with clinic tonometry in patients with glaucoma. Ophthalmol. Glaucoma 2021, 4, 569–580. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Medeiros, F.A.; Meira-Freitas, D.; Lisboa, R.; Kuang, T.-M.; Zangwill, L.M.; Weinreb, R.N. Corneal hysteresis as a risk factor for glaucoma progression: A prospective longitudinal study. Ophthalmology 2013, 120, 1533–1540. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Susanna, B.N.; Ogata, N.G.; Jammal, A.A.; Susanna, C.N.; Berchuck, S.I.; Medeiros, F.A. Corneal biomechanics and visual field progression in eyes with seemingly well-controlled intraocular pressure. Ophthalmology 2019, 126, 1640–1646. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Charlson, M.E.; De Moraes, C.G.; Link, A.; Wells, M.T.; Harmon, G.; Peterson, J.C.; Ritch, R.; Liebmann, J.M. Nocturnal systemic hypotension increases the risk of glaucoma progression. Ophthalmology 2014, 121, 2004–2012. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Van Eijgen, J.; Melgarejo, J.D.; Van Laeken, J.; Van der Pluijm, C.; Matheussen, H.; Verhaegen, M.; Van Keer, K.; Maestre, G.E.; Al-Aswad, L.A.; Vanassche, T.; et al. The relevance of arterial blood pressure in the management of glaucoma progression: A systematic review. Am. J. Hypertens. 2024, 37, 179–198. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Founti, P.; Bunce, C.; Khawaja, A.P.; Doré, C.J.; Mohamed-Noriega, J.; Garway-Heath, D.F. Risk factors for visual field deterioration in the United Kingdom Glaucoma Treatment Study. Ophthalmology 2020, 127, 1642–1651. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. De Moraes, C.G.; Juthani, V.J.; Liebmann, J.M.; Teng, C.C.; Tello, C.; Susanna, R., Jr.; Ritch, R. Risk factors for visual field progression in treated glaucoma. Arch. Ophthalmol. 2011, 129, 562–568. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Baek, S.U.; Ha, A.; Kim, D.W.; Jeoung, J.W.; Park, K.H.; Kim, Y.K. Risk factors for disease progression in low-teens normal-tension glaucoma. Br. J. Ophthalmol. 2020, 104, 81–86. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  17. Clement, C.I.; Bhartiya, S.; Shaarawy, T. New perspectives on target intraocular pressure. Surv. Ophthalmol. 2014, 59, 615–626. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Sit, A.J.; Pruet, C.M. Personalizing intraocular pressure: Target intraocular pressure in the setting of 24-hour intraocular pressure monitoring. Asia-Pac. J. Ophthalmol. 2016, 5, 17–22. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Konstas, A.G.P.; Kahook, M.Y.; Araie, M.; Katsanos, A.; Quaranta, L.; Rossetti, L.; Holló, G.; Detorakis, E.T.; Oddone, F.; Mikropoulos, D.G.; et al. Diurnal and 24-h intraocular pressures in glaucoma: Monitoring strategies and impact on prognosis and treatment. Adv. Ther. 2018, 35, 1775–1804. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Wang, S.Y.; Singh, K. Management of the glaucoma patient progressing at low normal intraocular pressure. Curr. Opin. Ophthalmol. 2020, 31, 107–113. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  21. Villasana, G.A.; Bradley, C.; Ramulu, P.; Unberath, M.; Yohannan, J. The effect of achieving target intraocular pressure on visual field worsening. Ophthalmology 2022, 129, 35–44. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. Montesano, G.; Garway-Heath, D.F.; Gazzard, G. Disease progression, not intraocular pressure, should guide escalation of treatment in glaucoma. Ophthalmol. Glaucoma 2025, 8, 427–430. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Wu, Z.; Medeiros, F.A. Comparison of visual field point-wise event-based and global trend-based analysis for detecting glaucomatous progression. Transl. Vis. Sci. Technol. 2018, 7, 20. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  24. Yu, M.; Lin, C.; Weinreb, R.N.; Lai, G.; Chiu, V.; Leung, C.K.-S. Risk of visual field progression in glaucoma patients with progressive retinal nerve fiber layer thinning: A 5-year prospective study. Ophthalmology 2016, 123, 1201–1210. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  25. Manik, D.; Ratanawongphaibul, K.; Kim, J.; Tsikata, E.; Lee, H.; Margeta, M.A.; Ondeck, C.L.; De Boer, J.F.; Chen, T.C. Frequency of agreement between structural and functional glaucoma testing: A longitudinal study of 3D OCT and current clinical tests. Am. J. Ophthalmol. 2024, 266, 196–205. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  26. Poleon, S.; Sabbagh, N.; Racette, L. Whitecoat adherence in patients with primary open-angle glaucoma. Front. Med. 2022, 9, 867884. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  27. Shu, Y.H.; Wu, J.; Luong, T.; Mattox, C.; Fang, E.N.; Lee, B.L.; Jones, J.P.; Campbell, J.; Shih, V.; Zhao, C.; et al. Topical medication adherence and visual field progression in open-angle glaucoma: Analysis of a large US health care system. J. Glaucoma 2021, 30, 1047–1055. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  28. Kamalipour, A.; Moghimi, S.; Eslani, M.; Nishida, T.; Mohammadzadeh, V.; Micheletti, E.; Girkin, C.A.; Fazio, M.A.; Liebmann, J.M.; Zangwill, L.M.; et al. A prospective longitudinal study to investigate corneal hysteresis as a risk factor of central visual field progression in glaucoma. Am. J. Ophthalmol. 2022, 240, 159–169. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Donkor, R.; Jammal, A.A.; Greenfield, D.S. Relationship Between Blood Pressure and Rates of Glaucomatous Visual Field Progression: The Vascular Imaging in Glaucoma Study. Ophthalmology 2025, 132, 30–38. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Marshall, H.; Mullany, S.; Qassim, A.; Siggs, O.; Hassall, M.; Ridge, B.; Nguyen, T.; Awadalla, M.; Andrew, N.H.; Healey, P.R.; et al. Cardiovascular Disease Predicts Structural and Functional Progression in Early Glaucoma. Ophthalmology 2021, 128, 58–69. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  31. Jammal, A.A.; Berchuck, S.I.; Mariottoni, E.B.; Tanna, A.P.; Costa, V.P.; Medeiros, F.A. Blood Pressure and Glaucomatous Progression in a Large Clinical Population. Ophthalmology 2022, 129, 161–170. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  32. Kastner, A.; Stuart, K.V.; Montesano, G.; De Moraes, C.G.; Kang, J.H.; Wiggs, J.L.; Pasquale, L.R.; Hysi, P.; Chua, S.Y.L.; Patel, P.J.; et al. Calcium Channel Blocker Use and Associated Glaucoma and Related Traits Among UK Biobank Participants. JAMA Ophthalmol. 2023, 141, 956–964. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  33. Aoyama, A.; Ishida, K.; Sawada, A.; Yamamoto, T. Target intraocular pressure for stability of visual field loss progression in normal-tension glaucoma. Jpn. J. Ophthalmol. 2010, 54, 117–123. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  34. Iverson, S.M.; Schultz, S.K.; Shi, W.; Feuer, W.J.; Greenfield, D.S. Effectiveness of single-digit IOP targets on decreasing global and localized visual field progression after filtration surgery in eyes with progressive normal-tension glaucoma. J. Glaucoma 2016, 25, 408–414. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  35. Schultz, S.K.; Iverson, S.M.; Shi, W.; Greenfield, D.S. Safety and efficacy of achieving single-digit intraocular pressure targets with filtration surgery in eyes with progressive normal-tension glaucoma. J. Glaucoma 2016, 25, 217–222. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  36. Medeiros, F.A.; Weinreb, R.N.; Moore, G.; Liebmann, J.M.; Girkin, C.A.; Zangwill, L.M. Integrating event- and trend-based analyses to improve detection of glaucomatous visual field progression. Ophthalmology 2012, 119, 458–467. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. De Moraes, C.G.; Song, C.; Liebmann, J.M.; Simonson, J.L.; Furlanetto, R.L.; Ritch, R. Defining 10-2 visual field progression criteria: Exploratory and confirmatory factor analysis using pointwise linear regression. Ophthalmology 2014, 121, 741–749. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  38. Rao, H.L.; Jonnadula, G.B.; Addepalli, U.K.; Senthil, S.; Garudadri, C.S. Effect of cataract extraction on Visual Field Index in glaucoma. J. Glaucoma 2013, 22, 164–168. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  39. Barkana, Y.; Anis, S.; Liebmann, J.; Tello, C.; Ritch, R. Clinical utility of intraocular pressure monitoring outside of normal office hours in patients with glaucoma. Arch. Ophthalmol. 2006, 124, 793–797. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  40. Scott, A.T.; Kanaster, K.; Kaizer, A.M.; Young, C.C.; Pantcheva, M.B.; Ertel, M.K.; Kahook, M.Y.; Seibold, L.K. The utility of iCare HOME tonometry for detection of therapy-related intraocular pressure changes in glaucoma and ocular hypertension. Ophthalmol. Glaucoma 2022, 5, 85–93. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  41. Bengtsson, B.; Leske, M.C.; Hyman, L.; Heijl, A.; Early Manifest Glaucoma Trial Group. Fluctuation of intraocular pressure and glaucoma progression in the Early Manifest Glaucoma Trial. Ophthalmology 2007, 114, 205–209. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  42. Caprioli, J.; Coleman, A.L. Intraocular pressure fluctuation: A risk factor for visual field progression at low intraocular pressures in the Advanced Glaucoma Intervention Study. Ophthalmology 2008, 115, 1123–1129.e3. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  43. Asrani, S.; Zeimer, R.; Wilensky, J.; Gieser, D.; Vitale, S.; Lindenmuth, K. Large diurnal fluctuations in intraocular pressure are an independent risk factor in patients with glaucoma. J. Glaucoma 2000, 9, 134–142. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  44. Lee, J.; Ahn, E.J.; Kim, Y.W.; Ha, A.; Kim, Y.K.; Jeoung, J.W.; Park, K.H. Impact of myopia on association of long-term intraocular pressure fluctuation with rate of progression in normal-tension glaucoma. Br. J. Ophthalmol. 2021, 105, 653–660. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  45. Hoban, K.; Peden, R.; Megaw, R.; Halpin, P.; Tatham, A.J. 24-hour contact lens sensor monitoring of intraocular pressure-related profiles in normal-tension glaucoma and rates of disease progression. Ophthalmic Res. 2017, 57, 208–215. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  46. Kim, Y.W.; Kim, J.S.; Lee, S.Y.; Ha, A.; Lee, J.; Park, Y.J.; Kim, Y.K.; Jeoung, J.W.; Park, K.H. Twenty-four-hour intraocular pressure-related patterns from contact lens sensors in normal-tension glaucoma and healthy eyes: The ENIGMA Study. Ophthalmology 2020, 127, 1487–1497. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  47. Gaboriau, T.; Dubois, R.; Foucque, B.; Malet, F.; Schweitzer, C. 24-hour monitoring of intraocular pressure fluctuations using a contact lens sensor: Diagnostic performance for glaucoma progression. Investig. Ophthalmol. Vis. Sci. 2023, 64, 3. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  48. Higashide, T.; Udagawa, S.; Nakazawa, K.; Yamashita, Y.; Tsuchiya, S.; Ohkubo, S.; Sugiyama, K. Prediction of glaucoma progression by 24-h contact lens sensor profile in patients with normal-tension glaucoma. Sci. Rep. 2024, 14, 21564. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  49. Burgoyne, C.F.; Downs, J.C.; Bellezza, A.J.; Suh, J.K.F.; Hart, R.T. The optic nerve head as a biomechanical structure: A new paradigm for understanding the role of IOP-related stress and strain in the pathophysiology of glaucomatous optic nerve head damage. Prog. Retin. Eye Res. 2005, 24, 39–73. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  50. Downs, J.C.; Girkin, C.A. Lamina cribrosa in glaucoma. Curr. Opin. Ophthalmol. 2017, 28, 113–119. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  51. NEIGHBORHOOD Consortium; Craig, J.E.; UK Biobank Eye and Vision Consortium; Han, X.; Qassim, A.; Hassall, M.; Bailey, J.N.C.; Kinzy, T.G.; Khawaja, A.P.; An, J.; et al. Multitrait analysis of glaucoma identifies new risk loci and enables polygenic prediction of disease susceptibility and progression. Nat. Genet. 2020, 52, 160–166. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  52. Siggs, O.M.; Qassim, A.; Han, X.; Marshall, H.N.; Mullany, S.; He, W.; Souzeau, E.; Galanopoulos, A.; Agar, A.; Landers, J.; et al. Association of High Polygenic Risk with Visual Field Worsening Despite Treatment in Early Primary Open-Angle Glaucoma. JAMA Ophthalmol. 2023, 141, 73–77. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  53. De Moraes, C.G.; Liebmann, J.M.; Greenfield, D.S.; Gardiner, S.K.; Ritch, R.; Krupin, T. Risk factors for visual field progression in the Low-Pressure Glaucoma Treatment Study. Am. J. Ophthalmol. 2012, 154, 702–711. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  54. Leske, M.C.; Heijl, A.; Hussein, M.; Bengtsson, B.; Hyman, L.; Komaroff, E.; Early Manifest Glaucoma Trial Group. Factors for glaucoma progression and the effect of treatment: The Early Manifest Glaucoma Trial. Arch. Ophthalmol. 2003, 121, 48–56. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  55. Gazzard, G.; Konstantakopoulou, E.; Garway-Heath, D.; Adeleke, M.; Vickerstaff, V.; Ambler, G.; Hunter, R.; Bunce, C.; Nathwani, N.; Barton, K.; et al. Laser in Glaucoma and Ocular Hypertension (LiGHT) Trial: Six-year results of primary selective laser trabeculoplasty versus eye drops for the treatment of glaucoma and ocular hypertension. Ophthalmology 2023, 130, 139–151. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  56. Salimi, A.; Clement, C.; Shiu, M.; Harasymowycz, P. Second-generation trabecular micro-bypass (iStent inject) with cataract surgery in eyes with normal-tension glaucoma: One-year outcomes of a multi-centre study. Ophthalmol. Ther. 2020, 9, 585–596. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  57. Oo, H.H.; Hong, A.S.Y.; Lim, S.Y.; Ang, B.C.H. Angle-based minimally invasive glaucoma surgery in normal tension glaucoma: A systematic review and meta-analysis. Clin. Exp. Ophthalmol. 2024, 52, 740–760. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  58. Carolan, J.A.; Liu, L.; Alexeeff, S.E.; Amsden, L.B.; Shorstein, N.H.; Herrinton, L.J. Intraocular Pressure Reduction After Phacoemulsification: A Matched Cohort Study. Ophthalmol. Glaucoma 2021, 4, 277–285. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  59. Richter, G.M.; Takusagawa, H.L.; Sit, A.J.; Rosdahl, J.A.; Chopra, V.; Ou, Y.; Kim, S.J.; WuDunn, D. Trabecular Procedures Combined with Cataract Surgery for Open-Angle Glaucoma: A Report by the American Academy of Ophthalmology. Ophthalmology 2024, 131, 370–382. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  60. Araújo-Azevedo, B.; Ferreira-da-Silva, R.; Barbosa-Breda, J. The efficacy and safety of reducing intraocular pressure to single-digit levels in normal-tension glaucoma: A systematic review and meta-analysis. Acta Ophthalmol. 2026, 104, 720–730. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  61. Gedde, S.J.; Schiffman, J.C.; Feuer, W.J.; Herndon, L.W.; Brandt, J.D.; Budenz, D.L.; Tube Versus Trabeculectomy Study Group. Treatment outcomes in the Tube Versus Trabeculectomy Study after five years of follow-up. Am. J. Ophthalmol. 2012, 153, 789–803.e2. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  62. Gedde, S.J.; Feuer, W.J.; Lim, K.S.; Barton, K.; Goyal, S.; Ahmed, I.I.; Brandt, J.D.; Primary Tube Versus Trabeculectomy Study Group. Treatment outcomes in the Primary Tube Versus Trabeculectomy Study after 5 years of follow-up. Ophthalmology 2022, 129, 1344–1356. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.