Next Article in Journal
Impact of On-Clopidogrel Platelet Reactivity on Incidence of Peri-Interventional Bleeding in Patients Undergoing Transcatheter Aortic Valve Implantation
Previous Article in Journal
The Importance of Arterial Stiffness Assessment in Patients with Familial Hypercholesterolemia
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Impaired Left Ventricular Circumferential Midwall Systolic Performance Appears Linked to Depressed Preload, but Not Intrinsic Contractile Dysfunction or Excessive Afterload, in Paradoxical Low-Flow/Low-Gradient Severe Aortic Stenosis

by
Dorota Długosz
1,
Andrzej Surdacki
1,2,
Barbara Zawiślak
3,
Stanisław Bartuś
1,2 and
Bernadeta Chyrchel
1,2,*
1
Department of Cardiology and Cardiovascular Interventions, University Hospital, 2 Jakubowskiego Street, 30-688 Cracow, Poland
2
Second Department of Cardiology, Institute of Cardiology, Jagiellonian University, 2 Jakubowskiego Street, 30-688 Cracow, Poland
3
Intensive Care Unit, Department of Cardiology and Cardiovascular Interventions, University Hospital, 2 Jakubowskiego Street, 30-688 Cracow, Poland
*
Author to whom correspondence should be addressed.
J. Clin. Med. 2022, 11(10), 2873; https://doi.org/10.3390/jcm11102873
Submission received: 3 April 2022 / Revised: 30 April 2022 / Accepted: 9 May 2022 / Published: 19 May 2022
(This article belongs to the Section Cardiology)

Abstract

Paradoxical low-flow/low-gradient aortic stenosis (P-LFLG-AS) occurs in about one-third of patients with severe AS and preserved left ventricular (LV) ejection fraction (EF). Our aim was to differentiate between altered LV loading conditions and contractility as determinants of subtle LV systolic dysfunction in P-LFLG-AS. We retrospectively analyzed medical records of patients with isolated severe degenerative AS and preserved EF (30 subjects with P-LFLG-AS and 30 patients with normal-flow/high-gradient severe AS (NFHG-AS)), without relevant coexistent diseases (e.g., diabetes, coronary artery disease and chronic kidney disease) or any abnormalities which could account for a low-flow state. Patients with P-LFLG-AS and NFHG-AS did not differ in aortic valve area index and most clinical characteristics. Compared to NFHG-AS, subjects with P-LFLG-AS exhibited smaller LV end-diastolic diameter (LVd) (44 ± 5 vs. 54 ± 5 mm, p < 0.001) (consistent with lower LV preload) with pronounced concentric remodeling, higher valvulo-arterial impedance (3.8 ± 1.1 vs. 2.2 ± 0.5 mmHg per mL/m2, p < 0.001) and diminished systemic arterial compliance (0.45 ± 0.11 vs. 0.76 ± 0.23 mL/m2 per mmHg, p < 0.001), while circumferential end-systolic LV midwall stress (cESS), an estimate of afterload at the LV level, was similar in P-LFLG-AS and NFHG-AS (175 ± 83 vs. 198 ± 69 hPa, p = 0.3). LV midwall fractional shortening (mwFS) was depressed in P-LFLG-AS vs. NFHG-AS (12.3 ± 3.5 vs. 14.7 ± 2.9%, p = 0.006) despite similar EF (61 ± 6 vs. 59 ± 8%, p = 0.4). By multiple regression, the presence of P-LFLG-AS remained a significant predictor of lower mwFS compared to NFHG-AS upon adjustment for cESS (β ± SEM: −2.35 ± 0.67, p < 0.001); however, the significance was lost after further correction for LVd (β = −1.10 ± 0.85, p = 0.21). In conclusion, the association of P-LFLG-AS with a lower cESS-adjusted mwFS, an index of afterload-corrected LV circumferential systolic function at the midwall level, appears secondary to a smaller LV end-diastolic cavity size according to the Frank–Starling law. Thus, low LV preload, not intrinsic contractile dysfunction or excessive afterload, may account for impaired LV circumferential midwall systolic performance in P-LFLG-AS.
Keywords: aortic stenosis; left ventricular systolic function; afterload; preload; low-flow state aortic stenosis; left ventricular systolic function; afterload; preload; low-flow state

Share and Cite

MDPI and ACS Style

Długosz, D.; Surdacki, A.; Zawiślak, B.; Bartuś, S.; Chyrchel, B. Impaired Left Ventricular Circumferential Midwall Systolic Performance Appears Linked to Depressed Preload, but Not Intrinsic Contractile Dysfunction or Excessive Afterload, in Paradoxical Low-Flow/Low-Gradient Severe Aortic Stenosis. J. Clin. Med. 2022, 11, 2873. https://doi.org/10.3390/jcm11102873

AMA Style

Długosz D, Surdacki A, Zawiślak B, Bartuś S, Chyrchel B. Impaired Left Ventricular Circumferential Midwall Systolic Performance Appears Linked to Depressed Preload, but Not Intrinsic Contractile Dysfunction or Excessive Afterload, in Paradoxical Low-Flow/Low-Gradient Severe Aortic Stenosis. Journal of Clinical Medicine. 2022; 11(10):2873. https://doi.org/10.3390/jcm11102873

Chicago/Turabian Style

Długosz, Dorota, Andrzej Surdacki, Barbara Zawiślak, Stanisław Bartuś, and Bernadeta Chyrchel. 2022. "Impaired Left Ventricular Circumferential Midwall Systolic Performance Appears Linked to Depressed Preload, but Not Intrinsic Contractile Dysfunction or Excessive Afterload, in Paradoxical Low-Flow/Low-Gradient Severe Aortic Stenosis" Journal of Clinical Medicine 11, no. 10: 2873. https://doi.org/10.3390/jcm11102873

APA Style

Długosz, D., Surdacki, A., Zawiślak, B., Bartuś, S., & Chyrchel, B. (2022). Impaired Left Ventricular Circumferential Midwall Systolic Performance Appears Linked to Depressed Preload, but Not Intrinsic Contractile Dysfunction or Excessive Afterload, in Paradoxical Low-Flow/Low-Gradient Severe Aortic Stenosis. Journal of Clinical Medicine, 11(10), 2873. https://doi.org/10.3390/jcm11102873

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop