Seawater-Based Hydrogen Production Integrated with LNG Cold Energy Recovery and Natural Gas Blending: Energy, Exergy, Environmental, and Economical Sensitivity Analysis

,
and
Department of Mechanical Engineering, Faculty of Engineering and Natural Sciences, Iskenderun Technical University, 31200 İskenderun, Türkiye
*
Author to whom correspondence should be addressed.
This article belongs to the Section Energy Science and Technology

Abstract

Storing hydrogen and using it directly continue to pose considerable technical difficulties and high economic costs. Injecting CH4/H2 blends into the current natural gas distribution infrastructure offers a viable pathway that removes the requirement for dedicated hydrogen storage. This study proposes a multi-cycle energy system that utilises LNG cold energy and seawater under real operating conditions to produce green hydrogen in liquefied natural gas (LNG) distribution stations. Monthly seawater temperature variations are incorporated into the analysis to evaluate the system performance throughout the year. The suggested configuration comprises four cycles operating with methane, R508B, and CO2 as working fluids, coupled with a PEM electrolyser. Detailed thermodynamic modelling was carried out in EBSILON® Professional 16 by Steag GmbH, Essen, Germany. According to the findings, the system delivers a maximum net power of 9.46 MW, along with overall energy and exergy efficiencies of 30.74% and 26.34%, respectively. Moreover, the system yields 13.747 MMNm3-H2 of green hydrogen annually, with a simple payback period of 4.39 years.

1. Introduction

Global population growth, industrialisation, and technological advancement have led to a continuous increase in energy demand, intensifying fossil fuel consumption and associated environmental problems [1]. Reducing fossil fuel dependence [2] and associated carbon emissions [3] is therefore essential for mitigating global climate change [3,4]. In line with international agreements such as the Kyoto Protocol and the Paris Agreement, the development of cleaner energy technologies and the integration of renewable energy resources have become key priorities [5]. In this context, electrolysis-based hydrogen production is increasingly considered a practical option for supporting low-carbon energy systems, particularly when the required electricity is supplied by renewable sources [6,7]. Integrating hydrogen production with renewable-energy-driven systems and heat recovery strategies can further improve energy utilisation and support cleaner energy conversion processes [8]. However, the storage and transportation of hydrogen remain costly because of its very low volumetric energy density, which requires high-pressure compression, liquefaction at cryogenic temperatures or dedicated infrastructure [9]. Blending hydrogen into the existing natural gas network has therefore emerged as one of the most promising approaches to mitigating these costs, as it enables hydrogen to be stored and transported using already available transmission and distribution infrastructure. In addition, hydrogen–methane blending is regarded as a practical pathway for decarbonising the gas sector, since it reduces carbon dioxide emissions at the point of end use. However, the amount of hydrogen that can be blended is limited, since hydrogen/methane blending alters the combustion properties and quality parameters of the gas, which must remain compatible with existing networks and end-use appliances. One of the most widely used parameters for assessing this compatibility is the Wobbe index, which characterises the interchangeability of fuel gases. It is defined as the ratio of the higher heating value of a gas to the square root of its relative density with respect to air (WI = HHV/√d) [10]. Gases with identical or similar Wobbe indices deliver comparable heat input and exhibit similar combustion behaviour in the same burner, without requiring modifications to the existing infrastructure or appliances. For this reason, grid gas quality specifications typically define an admissible Wobbe index range. The European standard EN 16726 recommends a Wobbe index range of 46.44–54.00 MJ/m3 (1 atm/15 °C) at network entry points [11]. Within this framework, several studies on hydrogen–methane blends have reported that hydrogen can be added to natural gas at concentrations of up to 20% by volume without significant modifications to the existing system infrastructure [12]. Liquefied natural gas (LNG), which generally has lower combustion-related carbon emissions than coal and oil, is widely regarded as a transitional fuel in the shift toward sustainable energy systems [13]. LNG is produced by liquefying natural gas at approximately −162 °C, resulting in a volume reduction of nearly 600 times, which enables efficient storage and transportation [14]. Owing to its transportability, wide application fields, and comparatively lower carbon intensity, LNG has gained strategic importance in global energy markets. In 2023, global LNG trade reached 401.42 million tons, with the Asia-Pacific region accounting for the largest share [13]. LNG is widely used in power generation, industrial processes, residential heating, transportation, and grid supply, making regasification processes increasingly significant. Following regasification, blending hydrogen into the methane-rich natural gas stream offers a practical transition pathway for reducing fuel carbon intensity while retaining existing gas infrastructure. Regasification also provides a cryogenic energy potential exceeding 800 kJ/kg, a substantial portion of which remains underutilised [15]. This growing LNG demand highlights the importance of recovering cold energy during regasification. LNG cold energy can act as an effective heat sink for low-temperature systems, and the organic Rankine cycle (ORC) has emerged as a suitable technology for converting low- and medium-grade thermal energy into electricity. Compared with conventional Rankine cycles, ORC systems employ working fluids with low boiling points, enabling improved performance under low-temperature conditions [16]. However, in most LNG terminals, this cold energy is still dissipated into the environment without recovery [17]. Accordingly, various LNG cold energy recovery strategies have been proposed to improve the efficiency of LNG regasification and supply chains [18]. These include direct expansion cycles, conventional and organic Rankine cycles, supercritical CO2 systems, and multi-generation configurations [19]. While direct expansion cycles offer structural simplicity, their applicability is limited, whereas ORC-based systems generally provide greater potential for low-temperature energy recovery. Consequently, cryogenic power generation systems that enable simultaneous regasification and electricity generation by exploiting LNG’s physical exergy have received increasing attention [20]. Beyond electricity generation, recovered LNG cold energy can be coupled with a proton exchange membrane (PEM) electrolyser to support hydrogen production. By using the generated power for electrolysis, LNG regasification exergy can be converted into useful energy products, thereby improving overall cold energy utilisation and supporting low-carbon energy conversion [21,22]. Previous studies on LNG cold energy recovery have mainly focused on improving power generation performance through different cycle configurations, working fluids, heat exchanger arrangements, and optimisation strategies. Early investigations demonstrated that the selection of cycle layout and working fluid has a significant influence on the recoverable work during LNG regasification. In this context, combined-cycle configurations and cryogenic power cycles have been analysed to maximise specific work output and reduce exergy losses [23]. Two-stage ORC and two-stage condensing Rankine configurations have also been proposed to improve the thermodynamic matching between LNG and the working fluid. For example, Xue et al. [24] reported a net power output of approximately 1776 kW from an optimised two-stage ORC system, while Bao et al. [25] showed that staged condensation could improve power output and thermodynamic efficiency by enhancing heat transfer during LNG regasification. Hybrid LNG cold energy recovery systems have also been investigated by combining LNG with renewable or low-grade heat sources. Such configurations aim to improve the temperature matching between the heat source and LNG cold sink, thereby increasing net power output and reducing exergy destruction. Mehrpooya et al. [26] demonstrated that integrating LNG cold energy with low-temperature solar heat could improve both energy and exergy efficiencies. The use of seawater as a sustainable heat source has also been reported to improve the performance of LNG-assisted ORC applications [27]. In addition, optimisation studies indicate that suitable heat exchanger design, cycle staging, and operating parameter selection can enhance net power output and reduce exergy losses without necessarily requiring additional major investment [28]. In parallel with these developments, LNG-based integrated systems have been extended beyond power generation toward hydrogen production, desalination, and energy storage applications. In this context, Chen et al. [29] developed a system integrating LNG cold energy recovery, ORC, PEM electrolysis, and seawater desalination. Their results showed clear seasonal variations, with cold energy utilisation efficiency increasing by 68.35–80.21% depending on the season, and exergy efficiency improving by 0.91–1.63% compared with the configuration without desalination. The system also achieved annual net earnings of USD 65,547.18, freshwater savings of 7688.34 m3/year, and CO2 emission reduction of 111.14 t/year, indicating both environmental and economic advantages of system integration. Bouzgarrou et al. [30] investigated a solar-powered multi-generation system integrating LNG cold energy recovery, cascaded ORCs, PEM electrolysis, and hydrogen liquefaction. The proposed system achieved a net power output of approximately 1.13 MW, a hydrogen production rate of 34.92 kg/h, and an overall exergy efficiency of 17.05%, with a levelized hydrogen cost of 3.59 USD/kg. Furthermore, the system provided approximately 192 kW of cooling capacity and reduced CO2 emissions by 255.96 kg/h. Similarly, Nikzad et al. [31] proposed a waste heat-driven ORC–PEM system for hydrogen production and liquefaction, reporting a hydrogen production rate of 26,8 kg/h and an exergy efficiency of 57%. More complex multi-generation configurations have also been investigated; for example, Khanmohammadi et al. [32] combined LNG cold energy with solar input, PEMFC, reverse osmosis desalination, and hydrogen production, achieving up to 276.1 kg/h of hydrogen production under optimised conditions. Their results also showed increases of approximately 26% in net power output and 39% in overall energy efficiency. However, the 201% increase in production revenue was accompanied by a 205.5% increase in payback period, suggesting a trade-off between improved technical performance and higher investment requirements. More recently, Ji et al. [33] investigated a hybrid wind–solar multi-generation system integrating LNG cold energy recovery with power generation, hydrogen liquefaction, cooling, and freshwater production. An artificial neural network-assisted multi-objective optimisation approach was employed to improve the system’s thermodynamic and economic performance. Under optimal conditions, the system achieved an exergy efficiency of 21.25%, a net power output of 1.39 MW, and a liquefied hydrogen production rate of 4.19 kg/h, while reducing the total cost rate by 29.6% compared with the baseline configuration. Hydrogen blending into existing natural gas networks requires careful consideration of permissible blending limits, pipeline material compatibility, and operational constraints [34,35]. Previous studies have highlighted challenges related to hydrogen embrittlement, gas quality variations, and the compatibility of end-use appliances [36,37]. These limitations should be considered when evaluating the feasibility of CH4/H2 mixtures in integrated LNG-based energy systems.
Overall, these studies demonstrate that while integrated systems significantly enhance energy efficiency and hydrogen production capacity, they often involve increased system complexity and economic trade-offs, and they rarely consider the influence of variable seawater conditions under realistic operating environments. The existing studies in this field have mainly focused on the use of LNG cold energy in conventional power recovery systems. It is observed that studies dealing with multi-cycle configurations that utilise seawater as a low-grade heat source are quite limited. Although some research has examined ultra-low-temperature systems based on LNG regasification, there are few studies on year-round sustainable seawater energy-based green hydrogen production. Very few studies have comprehensively investigated the year-round blending of green hydrogen into existing natural gas distribution networks at variable blending ratios without requiring modifications to the existing infrastructure. In addition, comprehensive analyses that combine thermodynamic, economic, and environmental aspects are almost absent, especially when seasonal variations in seawater temperature are taken into account.
As a first step, a seawater-based methane-ORC-CO2 system with LNG cold energy was designed to obtain the required thermodynamic outputs by depending on monthly average seawater temperatures ranging between 18 °C and 30 °C during a year. During the LNG regasification process, LNG was transmitted through a heat exchanger connected to seawater with varying temperature, and thermodynamic (gross power, net power, energy, and exergy) analyses were performed for each month over a year by using a turbine with a pressure ratio of 30. In the second step, the mass flow rates, gross power, net power, energy, and exergy efficiencies of the double cycle (ORC and CO2 systems) with LNG cold energy were evaluated monthly depending on varying seawater temperatures during the year (changing pressure ratios from approximately 37 to 7.48, respectively), and compared with each other. In addition, the net electrical power generated from the proposed system was utilised as an input to a PEM electrolyzer for hydrogen production. The green hydrogen production capacity was calculated for each operating condition under varying seawater temperature conditions. Following this, a detailed exergy analysis of the components used in the multi-cycle system was carried out. In the three-step version, the total investment cost, unit cost, investment feasibility, and payback period of the methane-ORC-CO2-PEM system with LNG cold energy system were evaluated by using the net present value (NPV) method. Finally, the multi-system’s environmental analysis was conducted. Its impact on CO2 emission reduction was also investigated by comparing conventional systems using three different types of conventional fuels.

2. Materials and Methods

2.1. Modelling

In the study, the methane, ORC and CO2 cycles were designed using Ebsilon® Professional 16 by Steag Steag GmbH, Essen, Germany. The software’s component library [38] is developed based on real industrial equipment. Accordingly, the thermophysical properties of the selected working fluids and seawater data are incorporated, and key technical parameters of each component, such as pressure drop and heat loss, pinch point temperature, etc., are adjusted. Before optimisation in the determined range, the thermodynamic properties were calculated and recorded in logical order, including enthalpy, entropy, specific heat, and specific exergy, at all points of a seawater-based power production system by utilising thermophysical databases of the fluids retrieved from the REFPROP library. The atmospheric air and seawater temperature data for the Dörtyol district’s Mediterranean coast of Hatay Province were provided by the Turkish State Meteorological Service. Dörtyol is a district of Hatay Province, Türkiye, located at 36°50′34″ N latitude and 36°13′28″ E longitude. Daily mean temperatures were averaged to obtain monthly values, which were then used to assess seasonal variations in the Results and Discussion section . The flow diagram and problem-solving process are given in Figure 1.
Figure 1. Flow diagram and problem-solving process.
Within the range of seawater temperatures varying throughout the year , the operating temperature and pressure conditions of R508B and CO2 were determined through parametric optimisation. The evaluation procedure is based on explicit decision criteria, as shown in Figure 1. An operating point was considered feasible if ΔTpinch > 5 K in all heat exchangers, Psat < P < Pcr for both the ORC and the CO2 Rankine cycle, and Tturbine,in < Tseawater. In addition, the working fluid had to enter the pump as a saturated or subcooled liquid and the turbine as a saturated or superheated vapour, with xturbine,out > 0.90. Among the feasible points, the one with the maximum ηth was selected for each month. Also, LNG drawn from the station was used as a cooling fluid. The variations in net power output, thermal efficiency, and exergy efficiency were evaluated over the entire year. In addition, mass flow rate, pump power consumption, gross power output, and component-based exergy analysis were assessed on a monthly basis. The monthly hydrogen production ( ṁ H 2 ) was calculated from the corresponding net power output (Ẇnet), and the annual production was obtained as the sum of the monthly values. The economic feasibility was assessed using the NPV method and the payback period, based on the cost formulations , and the annual hydrogen production and selling price. A positive NPVR indicates an economically feasible project, an NPVR of zero corresponds to the break-even condition, and a negative NPVR indicates that the project is not feasible under the assumed conditions. For the environmental analysis, the electricity generated by the system was assumed to replace that of conventional plants fuelled by natural gas, coke gas or coal. The avoided CO2 emissions were calculated from the fuel required for an equivalent power output, assuming stoichiometric combustion.
The analysis of the proposed system was performed based on the following assumptions:
•
The mass fraction of salt in the total mass of seawater was assumed to be 0.035 kg/kg.
•
A minimum pinch point temperature difference of 5 °C was specified for all heat exchangers.
•
Pressure drops in condensers, evaporators, and pipelines were assumed to be negligible.
•
The isentropic efficiency was set at 88% for the turbines and 80% for both the working fluid circulation pumps and the LNG feed pump.
•
The outlet pressure of the seawater pump was fixed at 2 bar.
•
All components were considered to operate under adiabatic conditions.
•
Kinetic and potential energy changes were neglected.
•
The composition of natural gas was assumed to be pure (100%) methane (CH4).
These assumptions were adopted to facilitate a consistent and realistic optimisation of the system in terms of thermodynamic efficiency, economic viability, energy and exergy performance, and environmental impacts. Comparative validation of present study with several models using different working fluids is given in Table 1.
Table 1. Comparative validation of the present study with several models using different fluids [39,40].

2.2. System Description

In recent years, systems such as the ORC have been increasingly employed both globally and in Türkiye for power generation utilising the cold energy released during the regasification of LNG. The working principle of the ORC is the same as that of the conventional RC. While water is used as the working fluid in the conventional RC, organic fluids that can evaporate at lower temperatures and reach higher pressures are preferred in ORC systems. The schematic flow and T-s diagrams of the proposed system designed in this study, where seawater is utilised as the heat source, are schematically presented in Figure 2. The system consists of three separate cycles.
Figure 2. The schematic and T-s diagrams of the combined cycle.
The schematic flow and T-s diagrams of the proposed system are presented in Figure 2. The system consists of three power cycles, namely the methane, ORC and CO2 cycles, and a PEM electrolysis unit. Seawater is used as the heat source of all three cycles, while the cold energy of LNG is utilised as the heat sink. The three power cycles are coupled through the LNG stream, which recovers the cold energy in two ways. In the methane cycle, LNG is pressurised in the liquid phase, which requires very low pumping work, and then expanded as gas in Turbine-1. In the ORC and CO2 cycles, the low-temperature methane leaving Turbine-1 is used to condense the working fluids in Condenser-1 and Condenser-2. The most important contribution of the LNG cold energy is that it lowers the condensation temperature and, consequently, the condensation pressure of the working fluids. As a result, R508B condenses at 1.00 bar (−87.83 °C) and CO2 at 6.02 bar (−53.04 °C). Without the LNG cold energy, the working fluids would have to be condensed by seawater or ambient air. In this case, R508B could not be condensed at all, since its critical temperature (11.20 °C) is below the seawater temperature, and CO2 would condense close to its critical point (about 72 bar at 30 °C). The low condensation pressures provided by the LNG cold energy therefore result in high turbine pressure ratios of approximately 37 in the ORC and 7.48 in the CO2 cycle, which considerably increase the power output. The net electrical power generated by the three cycles is supplied to the PEM electrolyser, and the produced hydrogen is blended into the regasified natural gas stream.
In the first cycle, referred to as the methane cycle, LNG at −162 °C and 1 bar is pressurised to 45 bar by Pump-1 (L4→L5). Since the critical pressure of methane is 45.99 bar, the pump outlet and turbine inlet pressure was set to 45 bar, so that the cycle operates under subcritical conditions. The LNG is evaporated in Evaporator-1 by seawater and leaves the evaporator as natural gas at 25 °C (L5→L6). The seawater is supplied by Pump-2 (L1→L2) and leaves the evaporator at a lower temperature (L2→L3). The gaseous methane expands to 1.5 bar in Turbine-1 (L6→L7) and produces mechanical work. The low-temperature gaseous methane leaving the turbine still contains a considerable amount of cold energy, which is recovered first in Condenser-1 (L7→L8) and subsequently in Condenser-2 (L8→L9). The regasified natural gas is finally sent to the distribution line at 1.5 bar (L9).
In the second cycle (ORC), R508B is used as the working fluid. Seawater supplied by Pump-4 (O1→O2) acts as the heat source in Evaporator-2 (O2→O3). The saturated liquid R508B leaving Condenser-1 is pressurised by Pump-3 (O4→O5) and is then evaporated and superheated in Evaporator-2 (O5→O6). Then, the vapour expands in Turbine-2 (O6→O7) and returns to Condenser-1 at low pressure. In Condenser-1, the LNG cold energy is used to condense R508B to the saturated liquid state (O7→O4) at a low condensation pressure (1.00 bar), while the temperature of the gaseous methane increases (L7→L8). The maximum pressure of the ORC (37.10 bar) is below the critical pressure of R508B (37.71 bar).
In the third cycle, CO2 is used as the working fluid. Seawater supplied by Pump-6 (C1→C2) acts as the heat source in Evaporator-3 (C2→C3). Liquid CO2 is pressurised by Pump-5 (C4→C5), evaporated and superheated in Evaporator-3 (C5→C6), and expanded in Turbine-3 (C6→C7). The CO2 leaving the turbine is condensed to the saturated liquid state in Condenser-2 (C7→C4) by the remaining cold energy of the methane stream leaving Condenser-1 (L8→L9). The CO2 cycle operates entirely under subcritical conditions. Both the evaporation pressure (45.00 bar) and the condensation pressure (6.02 bar) are well below the critical pressure of CO2 (Pcr = 73.77 bar), and the maximum cycle temperature (25.01 °C) is below its critical temperature (Tcr = 30.97 °C). In addition, the condensation pressure was kept above the triple-point pressure of CO2 (above 5.18 bar) to prevent the formation of solid CO2 in Condenser-2. For this reason, only condensation pressures above 5.18 bar were considered in the parametric optimisation.
The net electrical power generated by the methane, ORC and CO2 cycles is supplied to the PEM electrolyser, where purified water is split into hydrogen and oxygen (Equations (18)–(24)). The feed water is provided by a water purification unit, which is included in the economic analysis. The PEM electrolyser is assumed to operate at 30 bar and 60–80 °C. Since hydrogen leaves the electrolyser at a pressure higher than that of the regasified natural gas at the blending point (L9, 1.5 bar), it can be injected into the natural gas stream through a pressure regulation, metering and mixing unit without requiring a hydrogen compressor. Because the hydrogen is blended directly after production, no long-term hydrogen storage or transport is needed.

2.3. Working Fluids

The selection of the working fluid is a critical factor affecting the performance, efficiency, environmental impact, safety, equipment size, operating conditions, and economic feasibility of ORC systems [41,42]. From a thermodynamic perspective, properties such as boiling point, critical temperature, specific heat capacity, and latent heat of vaporisation directly influence cycle efficiency [43]. Environmental and safety considerations are also essential in fluid selection. Parameters such as GWP and ODP have become increasingly important, while non-toxic, non-ozone-depleting, and non-flammable or low-flammability fluids are preferred to reduce environmental impact and operational risks [44,45,46]. In this respect, CO2 is an attractive option because of its low cost, availability, non-toxic and non-flammable nature, zero ODP, and reference GWP value of 1 [47].
R508B, a mixture of approximately 54% R116 and 46% R23, is characterised by an extremely low boiling point and is classified as an ASHRAE A1 fluid due to its non-toxic and non-flammable properties [48]. These features make it suitable for low-temperature industrial and laboratory applications. During the selection of R508B, low-GWP natural refrigerants and hydrocarbons suitable for ultra-low-temperature applications were evaluated in terms of their normal boiling points, thermophysical properties under the target operating conditions, environmental impacts, and safety classifications. Although hydrocarbons offer environmental advantages due to their low GWP values, their high flammability requires additional safety measures at LNG regasification facilities [43,48]. Alternatives with higher normal boiling points may result in excessively low or sub-atmospheric condensing pressures at the targeted ultra-low temperatures, thereby increasing the risk of air or moisture ingress into the system under vacuum conditions. Furthermore, some refrigerants with low environmental impacts have application limitations related to toxicity, critical temperature, or other thermophysical properties. Therefore, R508B and CO2 were selected as the most suitable working fluids for the proposed system [43,48]. The thermophysical properties of the working fluids used in the methane–ORC–CO2 cycle are presented in Table 2.
Table 2. Thermophysical properties of organic fluids [42,43,47,48,49,50].

2.4. Mathematical Model

A wide range of organic working fluids can significantly influence the performance of ORC systems. In this study, the overall impact of different working fluids on system performance was thoroughly evaluated. For this purpose, energy and exergy analyses were carried out based on the first and second laws of thermodynamics [38]. Firstly, the principle of mass conservation states that the mass flow rate entering the system must equal the mass flow rate exiting the system:
∑ ṁ in = ∑ ṁ out
Here, ṁin represents the mass flow rate entering the system (kg/s), while ṁout denotes the mass flow rate leaving the system (kg/s). Energy conservation, based on the first law of thermodynamics, defines the balance between energy entering and leaving the system:
Q ˙ +   W ˙ = ∑ ( ṁ h ) out − ∑ ( ṁ h ) in
Here, Q ˙ and W ˙ represent the heat and work transfers into or out of the system, respectively. Also, h stands for the specific enthalpy. The exergy defines the system’s capacity to perform useful work and accounts for irreversibilities as follows:
E ˙ x in =   E ˙ x out +   E ˙ x dest
where the exergy flow is denoted by E ˙ x . The subscripts in, out, and dest represent the exergy entering, leaving, and destroyed within the system, respectively. Exergy flow is defined as a function of the mass flow rate and specific exergy:
Ex ˙   =   m ˙ ψ
ψ denotes the specific exergy, which represents the work potential of the fluid, and is expressed as follows:
ψ = h − h 0 − T 0   s − s 0
where h0 and s0 express the enthalpy and entropy values of the fluid at reference temperature, respectively. The work is considered to be fully convertible, whereas the potential of heat to be converted into exergy is more limited. The exergy associated with heat transfer is calculated using the following equation:
E ˙ x heat = 1 − T 0 T sur Q ˙
In this equation, Tsur represents the temperature of the heat transfer surface. T0 is also referred to ambient temperature [51]. The inlet heat source transferred to the working fluid is calculated as follows:
Q ˙ in ; Methane = m ˙ SW   h L 2 − h L 3
Q ˙ in ; ORC = m ˙ SW   h O 2 − h O 3
Q ˙ in ; CO 2 = m ˙ SW   h C 2 − h C 3
where m ˙ SW   denotes the mass flow rate of the seawater in the cycles. The net power output generated by the proposed systems is calculated by using the formula given below:
W ˙ net ; sys =   W ˙ turbine ; sys − W ˙ p ; sys
Here, W ˙ turbine ; sys represents the power produced by the turbine, while W ˙ p ; sys denotes the power consumed by the pump. The exergy input to the proposed systems is calculated as follows:
E ˙ in ; Methane =   m ˙ SW   ψ L 2 − ψ L 3 + m ˙ LNG   ψ L 5
E ˙ in ; ORC =   m ˙ SW   ψ O 2 − ψ O 3 + m ˙ LNG   ( ψ L 7 − ψ L 8 )
E ˙ in ; CO 2 =   m ˙ SW   ( ψ C 2 − ψ C 3 ) + m ˙ LNG   ( ψ L 8 − ψ L 9 )
The energy and exergy efficiencies of the designed systems are also calculated by using the following expressions:
η Sys =   Ẇ net Q ˙ in
Ԑ Sys =   Ẇ net Ė in
In addition, a performance analysis of each component of the ORC systems is conducted using energy and exergy equations. To evaluate the overall performance, the energy and exergy efficiencies of the combined cycle can be expressed as follows:
η Overall =   W ˙ net ; methane +   W ˙ net ; ORC +   W ˙ net ; CO 2 Q ˙ in , ; methane + Q ˙ in ;   CO 2 + Q ˙ in ;   ORC
Ԑ overall =   W ˙ net ; methane + W ˙ net ; ORC + W ˙ net ; CO 2 E ˙ in ; methane + E ˙ in ; CO 2 + E ˙ in , ; ORC
Hydrogen chemical formation equations are as follows:
Anode   reaction :   H 2 O → 2 H + + 2 e −   + 1 2 O 2
Cathode   reaction :   2 H + + 2 e − → H 2
Overall   reaction :   H 2 O + energy → H 2 + 1 2 O 2
The   total   energy   required :   Δ H = Δ G + T Δ S
In addition, the hydrogen production rate obtained from the net electrical energy generated by the system can be expressed as follows:
V H 2 =   W net SEC elec
where V H 2 represents the volumetric hydrogen production (Nm3), Wnet is the net electrical energy produced by the system (kWh), and SECelec denotes the specific energy consumption of the electrolyzer (kWh/Nm3). In this study, a practical value of 4.9 kWh/Nm3 was adopted for SECelec to reflect real operating conditions [52].
Considering the mass-based hydrogen production, the following relation can also be used:
m H 2 =   W net SEC elec × ρ H 2
where m H 2 is the mass of produced hydrogen (kg), and ρ H 2 is the density of hydrogen at normal conditions (0 °C and 1 atm). The hydrogen production was calculated on a monthly basis. Each month was represented by 30 days (720 h), which results in an annual base of 8640 h. A capacity factor of CF = 0.8767 was applied to account for maintenance and other downtime, giving an effective annual operating time of N = 7575 h. The annual hydrogen production was obtained as follows:
V H 2 , annual = ( CF ) x ∑ i ( V H 2 , i x   t month )

2.4.1. Economic Model

Developing sustainable solutions in the energy sector and utilising existing energy resources more efficiently are of significant economic and environmental importance. In this context, waste heat recovery systems such as the ORC contribute to increasing energy efficiency and reducing carbon emissions by harnessing low-temperature energy sources [53]. However, a comprehensive assessment of the investment costs, payback periods, and long-term economic benefits associated with ORC systems is required. In this section, the purchased equipment cost (PEC) and the total investment cost (TIC) were calculated. Also, the payback period (PB), along with the net present value method, was used to assess whether the proposed system represents a cost-effective alternative for applications in the energy sector and industry [54]. The capital cost correlations for the components used in the ORC are given in Table 3.
Table 3. PEC equations for each equipment used in the current system [54,55,56].
The Chemical Engineering Plant Cost Index (CEPCI), published by Chemical Engineering magazine, is a dimensionless index that reflects how the costs of equipment for power plants change over time. In this study, the purchase costs of equipment obtained from cost correlations developed in different years were updated to the reference year (2024) using the CEPCI [57].
Z updated   =   Z k , ref x CEPCI updated CEPCI ref
where Zk,ref is the purchase cost of the k-th component in the reference year of the correlation, Zupdated is the cost of the same component updated to the analysis year, and CEPCIref and CEPCIupdated are the index values for the reference year and the analysis year, respectively. Other fixed installation costs are presented in Table 4.
Table 4. The other fixed installation costs [39].
The PEM electrolyser and the water purification unit are included in the PEC (see Table 3) and, consequently, in the TIC. Since the produced hydrogen is directly blended into the regasified natural gas stream at the station, no hydrogen storage or long-distance transport is required. The PEM electrolyser delivers hydrogen at a pressure higher than that of the blending point; therefore, no hydrogen compressor is needed, and the costs of pressure regulation, metering and mixing equipment are considered within the fixed installation costs given in Table 4. The heat transfer surface area for calculating equipment cost of heat exchangers is given below:
A =   Q ˙ U ∗ LMTD
The LMTD represents logarithmic mean temperature difference, and is determined as follows:
LMTD =   Δ T max − Δ T min ln Δ T max Δ T min
ΔTmax and ΔTmin represent the maximum and minimum temperature differences between the inlet and outlet streams in the selected heat exchanger, respectively. Additionally, the material properties of the heat exchangers are among the most critical parameters affecting the heat transfer coefficient (U) [58]. According to previous studies in the literature [59,60], the U value is typically taken as 0.6 kW/m2·K for the evaporator and 0.5 kW/m2·K for the condenser. The economic baseline parameters adopted for the ORC system are presented in Table 5.
Table 5. Economic initial parameters [53,59,60,61,62].
Z ˙ total   represents the capital investment cost ratio based on the formula given below [63].
Z ˙ total = OFIC . CRF + PEC . CRF . ϕ N   ( $ / h )
where ϕ and N represent the operational factor and the number of annual operating hours, respectively. The capital recovery factor (CRF) is calculated using the following equation:
CRF =   i   ( 1 + i ) n ( 1 + i ) n − 1
Here, i represents the annual interest rate, and n denotes the lifetime of the plant. The other fixed investment cost (OFIC), which expresses the total of other fixed capital expenditures, is calculated as follows:
OFIC   =   TIC   −   PEC   ( $ )
In assessing the economic viability of the proposed power systems, the net present value (NPV) and net present value ratio (NPVR) play a significant role. A value greater than zero for these indicators implies that the investment is financially feasible. The NPV is calculated using the following expression:
NPV =   R annual   ( 1 + i ) n − 1 ( 1 + i ) n . i − TIC
where Rannual represents the total annual benefit in year, i denotes the discount rate (interest rate), and n indicates the project lifetime. NPVR is calculated as follows:
NPVR   =   NPV TIC
where if NPVR > 0, the investment is considered profitable; if NPVR < 0, the investment results in a loss; and if NPVR = 0, the investment is at the break-even point. However, the NPV and NPVR values alone are not sufficient to fully determine whether the proposed system meets the investment criteria within the targeted economic range. Therefore, the payback period emerges as another important evaluation criterion in investment decision-making. The payback period is considered in two distinct forms: the first is the simple payback period, which is not affected by the discount rate; the second is the discounted payback period, which, as expected, is significantly influenced by the discount rate. The formulas used to calculate both types of payback periods are presented below [64].
SPP = TCI R annual
The discounted payback period (DPP) is computed using the following equation:
DPP k = log m ˙ H 2 . n . c H 2 − ϕ m ˙ H 2 . n . c H 2 − ϕ − i . TIC log 1 + i
Here, m ˙ H 2 denotes the hydrogen production, n is the number of operating years, c H 2 represents the hydrogen sale price, ϕ is the investment cost, i is the discount rate, and t refers to the year. The hydrogen sale price ( c H 2 ) is accepted as $8 per kg [65]. The specific hydrogen production cost via the overall system is calculated as follows:
c H 2 , cost = ( OFIC ) . CRF + PEC . CRF . ϕ m ˙ H 2 . N   ( $ / kg H 2 )  

2.4.2. Environmental Analysis

In the present study, the low-temperature heat required during the regasification of LNG is supplied using seawater. Simultaneously, a waste heat recovery process is implemented through integration with an ORC system. This integrated system approach not only increases energy efficiency but also contributes to environmental sustainability by significantly reducing greenhouse gas emissions. Within this scope, the reduction in CO2 emissions for the proposed systems was calculated. In the analysis, the amount of electricity generated from waste heat recovered through the ORC subsystems was first determined. It is assumed that a conventional system would meet the power generation obtained from the proposed system. Therefore, to estimate the reduction in CO2 emissions, the amount of fuel required by the turbine to produce an equivalent amount of electricity and the corresponding heat input were first calculated as follows [53,54,66]:
Q ˙ heat needed = W ˙ net sub η sys
Here, Q ˙ heat needed represents the total heat input required by the conventional Rankine cycle or gas turbine to generate an amount of power equivalent to the net electric power produced by the subsystems. W ˙ net sub denotes the net power generated by the subsystem, while ηsys indicates the energy efficiency of the conventional power system. The energy efficiency of these cycles is accepted as 33%. Once Q ˙ heat needed   is determined, the total mass flow rate of fuel required to produce this amount of heat is calculated by using the following expression:
m ˙ fuel needed = Q ˙ heat needed LCV fuel
Here, m ˙ fuel needed is the molar flow rate of the fuel required, and LCVfuel denotes the lower calorific value of coke gas, coal and natural gas based on its molecular weight. Chemical composition of fuels used in environmental analysis is given in Table 6.
Table 6. Molar chemical composition of fuels used in environmental analysis [67,68].
Accordingly, the amount of CO2 emission avoided through the use of the methane-ORC-CO2 cycle can be calculated as follows:
m ˙ C O 2 reduced =   M C O 2 . n ˙ fuel needed . n C O 2 , fuel − burn
In this equation, m ˙ C O 2 reduced represents the amount of CO2 emission reduction achieved through the use of the subsystem, and M C O 2 denotes the molecular weight of carbon dioxide. The term n ˙ fuel needed refers to the required molar flow rate of fuel, and n C O 2 , fuel represents the number of CO2 moles generated per mole of fuel upon complete combustion for each fuel type.

3. Results and Discussion

This section aims to perform a thermodynamic and thermoeconomic analysis of power generation from an ORC system, in which low-temperature seawater is used as a heat source during the regasification of LNG. The parametric optimisation of the designed ORC cycles under specific operating conditions was carried out using EBSILON® Professional 16 software developed by Steag GmbH. The system consists of methane, ORC, and CO2 cycles. The system’s performance was comprehensively analysed by calculating monthly seawater and ambient temperatures, the mass flow rates of the proposed working fluids, the exergy destruction of the components, power generation, and energy and exergy efficiencies. In addition, the environmental and economic outlook of the proposed system is also evaluated. The monthly variation in average seawater and ambient temperatures throughout the year is shown in Figure 3.
Figure 3. Annual variation in average seawater and ambient temperatures for each month.
The monthly average ambient and seawater temperatures used in this study were based on real meteorological data. The measured values revealed significant seasonal variations throughout the year (Figure 3). The average ambient temperature increased from its minimum value of 12.73 °C in January to a maximum of 31.00 °C in August. Similarly, seawater temperature rose from 18.4 °C in January to 30.0 °C in August. A marked increase in seawater temperature was observed from May onward, reaching its highest levels in July and August, in parallel with the rise in ambient temperature. From September, both parameters gradually decreased, reaching 21.42 °C for seawater and 14.84 °C for ambient temperature in December. These results show that ambient and seawater temperatures are considerably higher in summer and remain relatively mild in winter. Compared with ambient temperature, seawater exhibited smaller fluctuations and slower cooling, mainly due to the higher thermal capacity of the marine environment. The fact that seawater temperatures remained higher than ambient temperatures during autumn and winter indicates its potential as a stable low-temperature heat source for ORC systems, provided that suitable working fluids are selected. When combined with LNG cold energy utilisation, low-temperature seawater may contribute to significant energy production while supporting the economical regasification of LNG. The annual variations in the mass flow rates of R508B and CO2, used in the LNG-integrated ORC system utilising low-temperature seawater, are presented in Figure 4.
Figure 4. Mass flow rate variations of the CO2 and R508B working fluids selected for the utilisation of seawater.
Figure 4 presents the variation in the mass flow rates of the R508B and CO2 working fluids used during the LNG regasification process throughout the year. It was observed that the mass flow rates of both fluids remained at low levels between January and March; however, with the onset of spring and the rise in seawater temperatures, a noticeable increase in mass flow rates was observed. In the CO2 cycle, the mass flow rate starts at 4.44 kg/s in January and reaches its peak at 7.13 kg/s in August. From September onwards, with the decrease in ambient temperatures, the mass flow rate declines, reaching 5.16 kg/s in December. The mass flow rate values in the R508B cycle are higher compared to the CO2 cycle. Beginning at 10.96 kg/s in January, the mass flow rate peaks at 16.62 kg/s in August and decreases to 12.43 kg/s in December. Monthly gross power output values obtained from the cycles during a year are observed in Figure 5.
Figure 5. Monthly gross power output values obtained from the cycles (graph on the left), and the percentage distribution showing the contribution of each cycle to the gross power generation (graph on the right).
Figure 5 presents the monthly gross power outputs of the methane, ORC, and CO2 cycles. For all three working fluids, gross power output exhibited seasonal fluctuations throughout the year. In general, an increasing trend was observed from March to August, followed by a decreasing trend beginning in September. The concentration of peak values in August for all fluids and the occurrence of the lowest values particularly in March indicate the seasonal variability of gross power generation over the year. Notably, the variation in seawater temperature, which is utilised in the ORC and CO2 power generation systems, is clearly the most influential factor affecting gross power output, as reflected in the graphical fluctuations. Figure 5 (graph on the right) illustrates the percentage contribution of each cycle to the total power generation. The methane cycle accounted for the majority of total power generation throughout the year, contributing between 87.03% and 92.28%, reaching as high as 92.28% during the winter and spring months. The ORC contributed between 4.86% and 8.26% over the year, with its highest contribution (8%) occurring in August. The contribution of the CO2 cycle ranged between 2.98% and 4.71%, with the highest value (5%) observed in August and September. For the CO2 cycle, the lowest gross power output was recorded in March at 252.86 kW, and the highest in August at 469.11 kW. In the ORC, the lowest value was 430.75 kW in March, while the highest was 822.76 kW in August. In the methane cycle, the gross power output ranged from 8173.72 kW in March to 8667.85 kW in August. It is evident that a significant amount of power can be obtained during the pressure and temperature reduction process of LNG in industrial zones. Additionally, the use of seawater at very low temperatures, especially when combined with LNG to utilise cold energy, clearly results in a substantial power generation potential. Monthly comparative analysis of the net power obtained from the methane R508B and CO2 cycles is given in Figure 6.
Figure 6. Monthly comparative analysis of the net power obtained from methane R508B and CO2.
According to the graph data in Figure 6, all three cycles exhibit similar trends in response to seasonal variations, with noticeable fluctuations in net power generation throughout the year. In the methane cycle, the lowest net power output was recorded in March at 7759.65 kW, while the highest value was observed in August at 8253.69 kW. Furthermore, the highest increase in net power output within the methane cycle is 2.33%, occurring between April and May. In the ORC, the net power output fluctuates between 396.26 kW and 770.11 kW over the year, with the highest and lowest values recorded in August and March, respectively. The most significant increase in this cycle occurred between April and May, with a rate of 32.40%. Similarly, in the CO2 cycle, the net power output was calculated as 232.54 kW in March and reached 436.41 kW in August. The highest increase in the CO2 cycle also occurred between April and May, with a rate of 30.18%. These findings indicate that the seasonal variations in seawater temperature have a pronounced effect on net power output in both the CO2 and ORC cycles. The results particularly highlight significant increases in the net power generation during the transition from spring to summer in these two cycles. In contrast, the greatest decreases in net power values for all cycles occurred between November and December. During this period, reductions of 15.35% in the CO2 cycle, 16.03% in the ORC, and 1.63% in the methane cycle were identified. These outcomes demonstrate that the performance of the cycles is significantly influenced by the seasonal temperature changes. The monthly variations in thermal efficiency and exergy efficiency for the methane, ORC, and CO2 cycles are presented in Figure 7.
Figure 7. Monthly variation in thermal efficiency and exergy efficiency values for the methane, ORC, and CO2.
Figure 7 presents a comparative illustration of the monthly energy and exergy efficiencies for the methane, ORC, and CO2 cycles integrated into the LNG regasification process. Upon examining the graphs, it is observed that the methane cycle exhibits a highly stable performance throughout the year, with energy efficiency ranging between 31.45% and 32.19%, and exergy efficiency between 24.78% and 25.79%. This indicates that the methane cycle is less affected by external environmental conditions and provides a consistent structure as the primary power generation source of the system. In contrast, the ORC is more sensitive to seasonal temperature variations; its energy efficiency increases from 21.79% in January to 22.96% during the summer months, while its exergy efficiency rises from 29.16% to 36.96%. This increase shows that higher seawater temperatures during summer positively influence the cycle’s performance. The CO2 cycle, on the other hand, achieves the highest exergy efficiency throughout the year, reaching 44.17% in the summer, up from 29.30% in January, while maintaining an energy efficiency between 16.53% and 16.98%. Due to its high thermal conductivity and the ability to operate at elevated cycle pressures, this cycle minimises exergy losses and delivers high thermodynamic performance. Generally, the methane cycle offers the most stable structure in terms of energy efficiency, the CO2 cycle stands out with superior exergy efficiency, and the ORC cycle reaches its peak performance in both efficiency metrics during the summer months in parallel with seasonal temperature increases. These findings highlight that the selection of cycles in ORC systems should not be limited to energy efficiency alone; instead, a comprehensive approach that also considers exergy effectiveness and environmental conditions is essential. The monthly variations in the overall system’s total energy and exergy efficiencies are calculated in Figure 8.
Figure 8. Monthly variation in the overall energy and exergy efficiencies of the proposed multi-cycle.
The monthly variation in overall energy and exergy efficiencies throughout the year is analysed in Figure 8, with an evaluation of seasonal fluctuations. According to the graphical data, energy efficiency exhibits a decreasing trend between January and March. However, an increase in overall efficiency is observed between April and August. While the total efficiency was recorded at 30.58% in January, it increased over the course of the year, particularly during the summer months. The highest overall efficiency value was recorded in August at 30.74%. This trend indicates that the net power contributions from the ORC and CO2 cycles are more effective during the summer months. The observed increase results from the improved performance of heat transfer mechanisms as seawater temperatures rise. It should be noted that, due to the relatively lower contribution of net power generation from the ORC and CO2 cycles compared to the methane cycle, no significant increases in total efficiency are observed throughout the year. The energy and exergy efficiencies obtained within the scope of this study demonstrated increases during the summer and autumn months, corresponding to thermodynamic variations throughout the year. In their studies, Bruno et al. [69] and Zonfrilli et al. [27] emphasised that system performance is sensitive to ambient temperature and that energy conversion efficiencies increase particularly at higher ambient temperatures. In this context, it is evident that seasonal conditions should be taken into consideration in the design of thermodynamic systems. Green hydrogen production through seawater-based multi-cycles and CH4/H2 blending ratios is observed in Figure 9.
Figure 9. Green hydrogen production and CH4/H2 blending ratios.
Figure 9 presents the monthly variation in hydrogen production obtained by utilising the electricity generated from the multi-cycle system in a PEM electrolyzer and CH4/H2 blending ratios. A total of 108,000 kg of LNG is distributed per hour at the considered LNG distribution facility. Each month was represented by 30 days (720 h), which gives an annual base of 8640 h. For each month, the hourly hydrogen production was obtained from the net power output at the maximum thermal efficiency operating point of that month with Equation (22). A capacity factor of CF = 0.8767 was applied to account for maintenance. In hydrogen–methane blends, the admissible hydrogen fraction is limited, since increasing hydrogen content alters the combustion characteristics of the gas and may eventually necessitate modifications to the existing infrastructure and end-use appliances. The Wobbe index is one of the key parameters used to define this limit. The European standard EN 16726 recommends a Wobbe index range of 46.44–54.00 MJ/m3 (1 atm/15 °C) for natural gas at network entry points, including gases blended with hydrogen. The Wobbe index calculated in this study for all CH4/H2 blends lies within this range, indicating that, from the standpoint of the Wobbe index, hydrogen can be blended with methane at concentrations of up to 20 mol% while maintaining gas interchangeability [10,11,70,71]. This blending approach therefore provides a practical pathway for the direct utilisation of green hydrogen without the need for dedicated hydrogen storage, which represents a substantial component of the overall hydrogen supply cost.
Hydrogen production varies throughout the year within the range of 1500.85–1692.60 Nm3/h. The minimum production is observed in March (1500.85 Nm3), whereas the maximum value is achieved in August (1692.60 Nm3/h). Accordingly, the difference between the minimum and maximum months is approximately 12.62%. The annual average hourly hydrogen production is calculated to be about 1591.03 Nm3/h. An examination of the monthly trend reveals that hydrogen production remains relatively low during the early months of the year. A decrease in the heat source temperature reduces the effective temperature difference across the cycles, thereby lowering the net power output and consequently the electrical power supplied to the PEM electrolyzer. As of April, a noticeable recovery in hydrogen production is observed. This increase can be associated with the improvement in the thermodynamic performance of the system due to rising seawater temperatures. During the summer months, the system reaches its peak production region. These results indicate that the maximum thermal potential of seawater in summer directly enhances the electricity generation capacity of the system. In other words, the hydrogen production performance of the proposed system is governed by the electrical consumption characteristics of the PEM unit and is also strongly influenced by the seasonal thermodynamic behaviour of the upper cycles. Following the summer period, a gradual decline in hydrogen production is observed. This decrease follows a smooth and controlled trend rather than an abrupt drop. This behaviour indicates that although the system is sensitive to seasonal variations, it maintains stable operation, and the reduction in heat source potential does not lead to sharp performance degradation. Therefore, the system provides a sustainable and balanced hydrogen production profile throughout the year. Seasonal averages further confirm this trend. The average hydrogen production is calculated as approximately 1527.25 Nm3/h in winter, 1532.06 Nm3/h in spring, 1661.36 Nm3/h in summer, and 1643.45 Nm3/h in autumn. Accordingly, the highest seasonal production occurs in summer, while the lowest is obtained in winter. The summer average is approximately 8.78% higher than that of winter. This difference indicates that the system performance is sensitive to seawater temperature conditions; however, this sensitivity remains within a manageable range. When the hourly average production values are evaluated together with the total operating duration, the annual hydrogen production is calculated as 13.747 MMNm3. Ultimately, the produced hydrogen was blended into the natural gas distribution system at molar concentrations ranging from 3.88% to 4.35% throughout the year. Considering these relatively low blending ratios (<5%), green hydrogen can be safely blended without requiring any remarkable modifications with the natural gas in the distribution system. A comparative analysis of exergy flow and exergy efficiencies in the main components of the methane, ORC, and CO2 cycles at the point of maximum performance is presented in Figure 10.
Figure 10. Comparative analysis of exergy flow and exergy efficiencies in the main components of the methane, ORC, and CO2 cycles at the point of maximum performance.
Figure 10 provides a comparative analysis of the exergy input, output, destruction, and efficiency values of the main components of the methane, ORC, and CO2 cycles. In the methane cycle, the turbine component exhibited 2715.21 kW of exergy destruction and an exergy efficiency of 76.17%. However, in the evaporator, a high exergy input of 16,262.4 kW yielded only 788.67 kW of output, with a destruction of 15,473.7 kW and a low efficiency of 4.85%. We calculated 2715.21 kW of destruction with an efficiency of 76.14% in the condenser, while the pump carries out exergy destruction of 210.75 kW, with an efficiency of 45.91%. In the ORC, the turbine receives up to 185.82 kW of destruction, resulting in an exergy efficiency of 81.58%. The condenser showed 607.36 kW of destruction, corresponding to 73.13% efficiency. The pump and evaporator operated with exergy efficiencies of 67.29% and 26.09%, respectively. The CO2 cycle emerges as the most efficient among the three, with the turbine achieving 89.10% exergy efficiency and only 57.40 kW of exergy destruction. The condenser, pump, and evaporator also demonstrated high efficiencies of 72.39%, 72.39%, and 43.92%, respectively. These results reveal that the CO2 cycle provides balanced and high efficiencies across all components, while the ORC stands out particularly in the turbine and condenser. Despite its high capacity, the methane cycle suffers from significant exergy losses in the evaporator. In similar studies, it has also been reported that turbines exhibit the highest exergy efficiency among the components of ORC systems, whereas significant exergy destructions occur in heat exchanger components such as evaporators and condensers [11,72,73]. It is observed that these results are appropriate for the present study. Economic indicators of the proposed system are calculated in Figure 11.
Figure 11. Economic indicators of the proposed system.
In the graph above, the bar chart on the left illustrates the overall capital investment cost and the PEC. The chart on the right presents economic evaluation indicators such as the unit energy cost, NPVR, SPP, and DPP. The total investment cost of the system, including the methane, ORC, CO2, the PEM electrolyser, and the water purification unit, was determined to be $37,851,291, of which $20,912,315 corresponds directly to the purchased equipment cost. These figures indicate that a significant portion of the initial investment (approximately 55.25%) is allocated to equipment procurement. According to the economic performance indicators, the unit energy production cost of the system was calculated as 5.06 $/kg-H2. As is known, for a proposed system to be considered a profitable investment, the NPVR must be greater than 0. The NPVR of this system was determined to be 0.64, indicating its economic feasibility. Finally, the SPP was calculated as 4.39 years, while the DPP was found to be 7.67 years. These indicators suggest that the investment can be recovered within a reasonable period compared with the 20-year project lifetime. The scenarios for sensitivity analysis and the results of the scenarios for sensitivity analysis in the economic analysis are given in Figure 12.
Figure 12. Evaluation of the scenarios for sensitivity analysis in the economic analysis.
The sensitivity analysis illustrates the impact of variations in key economic parameters on the NPV, DPP, SPP, and unit cost of the system. According to the results, a 20% increase in the total investment cost (TIC) leads to a reduction in NPV (17.98 M$), an extension of the payback period (DPP: 11.14, SPP: 5.26 years), and an increase in the unit cost (6.03 $/kg-H2). Conversely, a 20% decrease in TIC shortens the payback period to 3.51 years, improving overall profitability. A 20% increase in the interest rate significantly reduces the system’s economic attractiveness (NPV: 15.15 M$) and slows down investment recovery, whereas a 20% decrease in the interest rate enhances the financial feasibility (NPV: 36.21 M$,6.54 years). Changes in operation and maintenance costs have a limited yet noticeable effect on profitability. A 10% increase in annual operation time strengthens the revenue stream, resulting in a higher NPV (30.35 M$), while a 10% decrease lowers it to 17.98 M$ and extends the payback period to DPP: 9.72 and SPP: 4.95 years, respectively. A 10% increase in the hydrogen selling price strengthened the revenue stream, increasing the NPV to $31.73 million and reducing the DPP and SPP to 6.38 and 3.93 years, respectively. Conversely, a 10% decrease in the hydrogen selling price reduced the NPV to $16.59 million and extended the DPP and SPP to 9.72 and 4.95 years, respectively. In both scenarios, the unit production cost of hydrogen remained constant at $5.06/kg-H2. Overall, the most influential parameters affecting the system’s economic performance are the investment cost and interest rate, while operation and maintenance expenses exhibit a relatively minor sensitivity. The contribution of the methane-ORC-CO2 to emission reduction according to different fuel types is calculated in Figure 13.
Figure 13. Contribution of the methane-ORC-CO2 to emission reduction according to different fuel types.
As is well known, numerous energy conversion systems such as Brayton and Rankine cycles are used globally. Due to regional factors, various fuel types are preferred in these systems. However, coal and natural gas are the most commonly used fuels for large-scale power generation. Therefore, for the assessment of CO2 emission reduction, natural gas, coal, and coke oven gas were selected. In Figure 13, the power generated by the methane, ORC, and CO2 cycles is assumed to be produced by systems operating on these fuel types. In January, CO2 reduction achieved using natural gas was calculated as 5088.46 kgCO2/h, and this value increased during the summer months, reaching a maximum of 5677.30 kgCO2/h in August. When coal is used, the CO2 reduction was determined to be 10,647.71 kgCO2/h in January and reached about 11,879.86 kgCO2/h during the August period. Regarding the coke gas, CO2 emission reduction remained within the range of 4498.96–5019.58 kgCO2/h throughout the year. Over one year, the CO2 emission reductions achieved from the proposed system through the use of these three different fuel types were calculated as 40.42 kt/year for natural gas, 35.74 kt/year for coke gas, and 84.59 kt/year for coal. These findings demonstrate the contribution of the proposed multi-cycle to environmental sustainability and its potential in reducing greenhouse gas emissions. Comparison of working fluids, operating parameters, and thermodynamic performance with academic studies is given in Table 7.
Table 7. Comparison of working fluids, operating parameters, and thermodynamic performance with academic studies.
In Table 7, the limited academic studies reveal that a wide variety of organic fluids have been employed. However, most of these working fluids are flammable. In addition, seawater has been widely utilised as a preheating source. Furthermore, studies examining a system producing seawater-based green hydrogen at LNG distribution stations by considering the monthly variations in seawater temperature throughout the year are quite limited. Compared with the existing literature, the methane-R508-CO2-PEM system exhibits superior characteristics in terms of net power value as well as thermal and exergy efficiencies. Thermophysical properties at each point of the power cycles at the maximum performance point are given in Table 8.
Table 8. Thermophysical properties at each point of the power cycles at maximum performance points.

4. Conclusions

A methane–ORC–CO2–PEM system using seawater as the heat source and LNG cold energy as the heat sink was analysed on a monthly basis for an LNG regasification terminal. The main conclusions are as follows.

4.1. Energy and Exergy

The methane cycle is the main and most stable power unit, supplying 92.28% of the net power (8.25 MW) with energy and exergy efficiencies of 32.19% and 25.79%, respectively. The ORC and CO2 cycles provide up to 1.206 MW (12.75%) of the maximum net power. Although the turbine inlet temperatures of the ORC and CO2 cycles are approximately close to each other (25 °C, 25.01 °C), the ORC has a higher energy efficiency (up to 22.96%) than the CO2 cycle (up to 16.98%) because the turbine pressure ratio of the ORC (PR:37) is higher than the CO2 cycle (PR:7.48). However, the CO2 cycle has the highest exergy efficiency (up to 44.17%, compared with 36.96% for the ORC), as it uses the LNG cold energy at a higher temperature level with lower exergy destruction. The overall system reaches a maximum net power of 9.46 MW in August, with overall energy and exergy efficiencies of 30.74% and 26.34%.

4.2. Hydrogen Production

The proposed subsystems were found to be sensitive to seasonal seawater temperature changes, with their highest efficiency achieved during the summer months. The proposed system provides sustainable energy due to the longer annual operating period compared to other sustainable systems. Also, the average hydrogen production was determined as 1527.25 Nm3/h in winter, 1532.06 Nm3/h in spring, 1661.36 Nm3/h in summer, and 1643.45 Nm3/h in autumn with the highest and lowest values observed in summer and winter, respectively. The summer average was approximately 8.78% higher than that of winter. Considering a capacity factor of 0.8767 (7575 h), the annual total hydrogen production was calculated as 13.747 MMNm3, indicating a strong overall production capacity of the proposed system.
Although the volumetric HHV value of hydrogen is approximately one third that of methane, its very low relative density (d ≈ 0.0695) results in a Wobbe index close to that of methane (45.9 MJ/m3 versus 50.7 MJ/m3 at standard conditions). Consequently, the reduction in the Wobbe index of the blend is considerably smaller than the reduction in its volumetric heating value. For the CH4/H2 mixture containing the maximum 4.35 mol% hydrogen produced in this study, the HHV value decreases by 3%, whereas the Wobbe index decreases by only 1.1%, to 50.2 MJ/m3 under standard conditions. The Wobbe index of this blend therefore remains within the range of 46.44–54.00 MJ/m3 recommended by EN 16726 for network entry points. These results indicate that the calculated characteristics of the mixture meet the gas-quality requirements for transport and distribution at hydrogen concentrations up to 4.35 mol%. However, hydrogen blending may cause changes at the point of end use, such as in flame speed and burner operation, and the compatibility of pipeline materials and end-use equipment should be assessed separately for each specific application.

4.3. Economic Aspect

The total investment cost, including the PEM electrolyser, is USD 37.85 million. The unit cost of hydrogen is 5.06 USD/kg-H2, the NPVR is 0.64, and the SPP and DPP are 4.39 and 7.67 years, confirming the economic feasibility of the system. The sensitivity analysis shows that the NPV and NPVR remain positive even in the worst scenarios. The investment cost has the greatest effect on the payback periods and the unit cost; in the worst case (+20% TIC), the DPP and SPP increase to 11.14 and 5.26 years and the unit cost to 6.03 USD/kg-H2. Operation and maintenance costs have the smallest effect.

4.4. Environmental Aspect

The system delivered significant environmental benefits thanks to notable reductions in CO2 emissions (up to 84.59 kt/year) compared to traditional fossil fuel-based energy generation. The methane cycle provides 89.9% of this reduction, corresponding to 36.33, 32.13 and 76.03 kt CO2/year for natural gas, coke gas and coal, respectively, while the ORC provides 6.4% of this CO2 reduction, corresponding to 2.60, 2.30 and 5.44 kt CO2/year for natural gas, coke gas and coal, respectively. The CO2 cycle performs 3.7% of the CO2 reduction, corresponding to 1.49, 1.32 and 3.12 kt CO2/year for natural gas, coke gas and coal, respectively. Overall, integrating seawater heat with LNG cold energy offers a technically, economically and environmentally viable pathway for hydrogen production and natural gas blending at coastal LNG terminals.

Author Contributions

Conceptualisation, N.E.M. and Ö.K.; methodology, Ö.K.; software, N.E.M., Y.K. and Ö.K.; validation, Y.K.; investigation, N.E.M.; data curation, Y.K. and Ö.K.; writing—original draft preparation, N.E.M.; writing—review and editing, Ö.K.; visualisation, Ö.K.; supervision, Y.K. and Ö.K. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

Data presented in this study can be obtained from the corresponding author upon reasonable request.

Acknowledgments

This paper was produced from a part of my doctoral dissertation prepared under the supervision of Yıldız KOÇ and Özkan KÖSE.

Conflicts of Interest

The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

Abbreviations

The following abbreviations are used in this manuscript:
AArea (m2)
CFCapacity factor
CRFCapital recovery factor
cCost of electricity
CO2Carbon dioxide
DEDirect expansion
DPPDiscounted payback period
DCORCDual-stage condensing organic Rankine cycle
ĖExergy flow (kw)
GWPGlobal warming potential
hEnthalpy (kj/kg)
HFCHydrofluorocarbon
iInterest rate (%)
LCOELevelized cost of electricity
LCVLower calorific value
LHVLower heating value
LMTDLogarithmic mean temperature difference
LNGLiquefied natural gas
ṁMass flow rate (kg/s)
nLifetime (year)
NAnnual operation time (h)
NPVNet present value
NPVRNet present value ratio
ODPOzone depletion potential
OFICOther fixed investment cost
ORCOrganic Rankine cycle
PPressure (bar)
PuseUsed pressure value in analysis
PBPayback period (year)
PECPurchased equipment cost ($)
PEMProton exchange membrane
PRPressure ratio
Q ˙ Heat flow (kw)
RTotal annual benefit
RCRankine cycle
rRelative cost difference (%)
sEntropy (kj/kgk)
SPPSimple payback period
SICSpecific investment cost
sCO2Supercritical CO2
T0Ambient temperature (°C)
TTemperature (°C)
TICTotal investment cost
TCRCTwo-stage condensing Rankine cycle
UHeat transfer coefficient (kw/m2k)
ẆPower (kw)
WIWobbe index
ŻCapital investment cost ratio
Greek letters
ψSpecific exergy (kj/kg)
ηEnergy efficiency (%)
εExergy efficiency (%)
ϕ Maintenance factor (%)
Subscripts
bBoil
condCondenser
crCritical
destDestruction
detDeterioration
elElectricity
evaEvaporator
inInlet
maxMaximum
minMinimum
outOutlet
pPump
surHeat transfer surface
swSea water
sysSystem
tTurbine

References

  1. Kumar, S.; Kwon, H.T.; Choi, K.H.; Lim, W.; Cho, J.H.; Tak, K.; Moon, I. LNG: An eco-friendly cryogenic fuel for sustainable development. Appl. Energy 2011, 88, 4264–4273. [Google Scholar] [CrossRef] [Scilit]
  2. Dincer, I.; Aydin, M.I. New paradigms in sustainable energy systems with hydrogen. Energy Convers. Manag. 2023, 283, 116950. [Google Scholar] [CrossRef] [Scilit]
  3. Arat, H.T.; Baltacioglu, M.K.; Tanç, B.; Sürer, M.G.; Dincer, I. A perspective on hydrogen energy research, development and innovation activities in Turkey. Int. J. Energy Res. 2020, 44, 588–593. [Google Scholar] [CrossRef] [Scilit]
  4. Alayi, R.; Ebazadeh, Y. Modelling and control of a hybrid renewable energy based hydrogen and electricity production and storage systems. Int. J. Low-Carbon Technol. 2025, 20, 1544–1553. [Google Scholar] [CrossRef] [Scilit]
  5. Miyamoto, M.; Takeuchi, K. Climate agreement and technology diffusion: Impact of the Kyoto Protocol on international patent applications for renewable energy technologies. Energy Policy 2019, 129, 1331–1338. [Google Scholar] [CrossRef] [Scilit]
  6. Nowotny, J.; Veziroglu, T.N. Impact of hydrogen on the environment. Int. J. Hydrogen Energy 2011, 36, 13218–13224. [Google Scholar] [CrossRef] [Scilit]
  7. Veziroglu, T.N.; Şahin, S. 21st Century’s energy: Hydrogen energy system. Energy Convers. Manag. 2008, 49, 1820–1831. [Google Scholar] [CrossRef] [Scilit]
  8. Kenez, M.C.; Dincer, I. Development and assessment of an offshore-based integrated hydrogen production and liquefaction system. Appl. Therm. Eng. 2024, 236, 121574. [Google Scholar] [CrossRef] [Scilit]
  9. El Farnini, O.; Nachtane, M.; Elrhoul, D.; Trihi, M. Optimizing hydrogen logistics: A techno-economic comparison of compressed and liquid hydrogen systems. Int. J. Hydrogen Energy 2026, 221, 154210. [Google Scholar] [CrossRef] [Scilit]
  10. Franco, A.; Rocca, M. Industrial decarbonization through blended combustion of natural gas and hydrogen. Hydrogen 2024, 5, 519–539. [Google Scholar] [CrossRef] [Scilit]
  11. EN 16726:2025; Gas Infrastructure-Quality of Gas-Group H. European Committee for Standardization (CEN): Brussels, Belgium, 2025.
  12. Köse, Ö.; Koç, Y. Evaluation of emission effect of hydrogen-mixed natural gas. In Proceedings of the 7th International Trakya Scientific Research and Innovation Congress, Edirne, Türkiye, 28–29 August 2025; pp. 191–200. [Google Scholar]
  13. International Gas Union. 2024 World LNG Report. Available online: https://www.igu.org/igu-reports/2024-world-lng-report (accessed on 17 November 2024).
  14. Khanmohammadi, S.; Musharavati, F.; Khan, M.S. Proposal a new hybrid system comprising of LNG regasification and geothermal sources: Exergy, exergo-economic, and optimization. Sustain. Energy Technol. Assess. 2023, 60, 103525. [Google Scholar] [CrossRef] [Scilit]
  15. Mehrpooya, M.; Kalhorzadeh, M.; Chahartaghi, M. Investigation of novel integrated air separation processes, cold energy recovery of liquefied natural gas and carbon dioxide power cycle. J. Clean. Prod. 2016, 113, 411–425. [Google Scholar] [CrossRef] [Scilit]
  16. Goyal, A.; Sherwani, A.F.; Tiwari, D.; Kumar, A. Sensitivity analysis and multi-objective optimization of organic Rankine cycle integrated with vapor compression refrigeration system. Energy Sources Part A Recovery Util. Environ. Eff. 2025, 47, 7132–7144. [Google Scholar] [CrossRef] [Scilit]
  17. Messineo, A.; Panno, D. Potential applications using LNG cold energy in Sicily. Int. J. Energy Res. 2008, 32, 1058–1064. [Google Scholar] [CrossRef] [Scilit]
  18. Atienza-Márquez, A.; Bruno, J.C.; Coronas, A. Cold recovery from LNG-regasification for polygeneration applications. Appl. Therm. Eng. 2018, 132, 463–478. [Google Scholar] [CrossRef] [Scilit]
  19. Bao, J.; Lin, Y.; Zhang, R.; Zhang, N.; He, G. Effects of stage number of condensing process on the power generation systems for LNG cold energy recovery. Appl. Therm. Eng. 2017, 126, 566–582. [Google Scholar] [CrossRef] [Scilit]
  20. Eghtesad, A.; Afshin, H.; Hannani, S.K. Energy, exergy, exergoeconomic, and economic analysis of a novel power generation cycle integrated with seawater desalination system using the cold energy of liquified natural gas. Energy Convers. Manag. 2021, 243, 114352. [Google Scholar] [CrossRef] [Scilit]
  21. Emadi, M.A.; Pourrahmani, H.; Moghimi, M. Performance evaluation of an integrated hydrogen production system with LNG cold energy utilization. Int. J. Hydrogen Energy 2018, 43, 22075–22087. [Google Scholar] [CrossRef] [Scilit]
  22. Soyturk, G.; Kizilkan, O. An innovative OTEC and PV/T-based multi-generation system with LNG cold energy recovery for sustainable production of hydrogen and distilled water. Int. J. Hydrogen Energy 2024, 75, 613–624. [Google Scholar] [CrossRef] [Scilit]
  23. Badami, M.; Bruno, J.C.; Coronas, A.; Fambri, G. Analysis of different combined cycles and working fluids for LNG exergy recovery during regasification. Energy 2018, 159, 373–384. [Google Scholar] [CrossRef] [Scilit]
  24. Xue, X.; Guo, C.; Du, X.; Yang, L.; Yang, Y. Thermodynamic analysis and optimization of a two-stage organic Rankine cycle for liquefied natural gas cryogenic exergy recovery. Energy 2015, 83, 778–787. [Google Scholar] [CrossRef] [Scilit]
  25. Bao, J.; Lin, Y.; Zhang, R.; Zhang, N.; He, G. Strengthening power generation efficiency utilizing liquefied natural gas cold energy by a novel two-stage condensation Rankine cycle (TCRC) system. Energy Convers. Manag. 2017, 143, 312–325. [Google Scholar] [CrossRef] [Scilit]
  26. Mehrpooya, M.; Sharifzadeh, M.M.M.; Rosen, M.A. Energy and exergy analyses of a novel power cycle using the cold of LNG (liquefied natural gas) and low-temperature solar energy. Energy 2016, 95, 324–345. [Google Scholar] [CrossRef] [Scilit]
  27. Zonfrilli, M.; Facchino, M.; Serinelli, R.; Chesti, M.; De Falco, M.; Capocelli, M. Thermodynamic analysis of cold energy recovery from LNG regasification. J. Clean. Prod. 2023, 420, 138443. [Google Scholar] [CrossRef] [Scilit]
  28. Joy, J.; Chowdhury, K. Appropriate number of stages of an ORC driven by LNG cold energy to produce acceptable power with reasonable surface area of heat exchangers. Cryogenics 2022, 128, 103599. [Google Scholar] [CrossRef] [Scilit]
  29. Chen, C.; Mu, H.; Li, N.; Zhao, X.; Song, Y.; Wang, H. Comparative analysis of a novel system integrating ORC, hydrogen production, and seawater desalination with LNG cold energy: Energy, economic, and environmental analyses. Energy Fuels 2023, 37, 16461–16475. [Google Scholar] [CrossRef] [Scilit]
  30. Bouzgarrou, S.; Abed, A.M.; Chauhan, B.S.; Alsenani, T.R.; Alharbi, F.S.; Alkhalaf, S.; Albaijan, I.; Abdullaeva, B.S.; Deifalla, A. Thermo-economic-environmental evaluation of an innovative solar-powered system integrated with LNG regasification process for large-scale hydrogen production and liquefaction. Case Stud. Therm. Eng. 2024, 53, 103904. [Google Scholar] [CrossRef] [Scilit]
  31. Nikzad, A.; Mafi, M.; Faramarzi, S. A system to store waste heat as liquid hydrogen assisted by organic Rankine cycle, proton exchange membrane electrolyzer, and mixed refrigerant hydrogen liquefaction cycle. Energy Storage 2024, 6, e70064. [Google Scholar] [CrossRef] [Scilit]
  32. Khanmohammadi, S.; Khanjani, S.; Chaghakaboodi, H.A. Investigation of an integrated clean energy system using heat recovery from fuel cell and LNG expansion waste heat combined with solar energy. Environ. Prog. Sustain. Energy 2025, 44, e70029. [Google Scholar] [CrossRef] [Scilit]
  33. Ji, L.; Basem, A.; Balla, H.H.A.; Alkhatib, O.J.; Alkhattabi, K.; Li, Y.; Ahmed, M.A.; Alanazi, M.; Albalawi, H.; Mahariq, I. Integrated Wind-Solar-LNG system for green liquefied hydrogen and multi-energy supply: Techno-Economic-Environmental analysis and data-driven ANN-GA optimization. Fuel 2026, 419, 138864. [Google Scholar] [CrossRef] [Scilit]
  34. Erdener, B.C.; Sergi, B.; Guerra, O.J.; Chueca, A.L.; Pambour, K.; Brancucci, C.; Hodge, B.M. A review of technical and regulatory limits for hydrogen blending in natural gas pipelines. Int. J. Hydrogen Energy 2023, 48, 5595–5617. [Google Scholar] [CrossRef] [Scilit]
  35. Sofian, M.; Haq, M.B.; Al Shehri, D.; Rahman, M.M.; Muhammed, N.S. A review on hydrogen blending in gas network: Insight into safety, corrosion, embrittlement, coatings and liners, and bibliometric analysis. Int. J. Hydrogen Energy 2024, 60, 867–889. [Google Scholar] [CrossRef] [Scilit]
  36. Rosa, N.; Fereidani, N.A.; Cardoso, B.J.; Martinho, N.; Gaspar, A.; da Silva, M.G. Advances in hydrogen blending and injection in natural gas networks: A review. Int. J. Hydrogen Energy 2025, 105, 367–381. [Google Scholar] [CrossRef] [Scilit]
  37. Bloj, M.D.; Ripeanu, R.G.; Diniță, A.; Oprea, V.O.; Tănase, M. Comprehensive review of hydrogen-natural gas blending: Global project insights with a focus on implementation and impact in Romanian gas networks. Heliyon 2025, 11, e43090. [Google Scholar] [CrossRef] [Scilit]
  38. Köse, Ö.; Koç, Y.; Yağlı, H. Performance improvement of the bottoming steam Rankine cycle (SRC) and organic Rankine cycle (ORC) systems for a multi-cycle combined system using gas turbine (GT) as topping cycle. Energy Convers. Manag. 2020, 211, 112745. [Google Scholar] [CrossRef] [Scilit]
  39. Köse, Ö. Solar energy storage assisted green hydrogen production: A thermo-economic assessment. Int. J. Hydrogen Energy 2025, 170, 151192. [Google Scholar] [CrossRef] [Scilit]
  40. Chaudhary, A.; Mulchand, A.; Dave, P. Feasibility Study of Supercritical CO2 Rankine Cycle for Waste Heat Recovery. In Proceedings of the 6th International Symposium-Supercritical CO2 Power Cycles, Pittsburgh, PA, USA, 27–29 March 2018; pp. 27–29. [Google Scholar]
  41. Arjunan, P.; Gnana Muthu, J.H.; Somanasari Radha, S.L.; Suryan, A. Selection of working fluids for solar organic Rankine cycle-a review. Int. J. Energy Res. 2022, 46, 20573–20599. [Google Scholar] [CrossRef] [Scilit]
  42. Kolasiński, P. The method of the working fluid selection for organic Rankine cycle (ORC) systems employing volumetric expanders. Energies 2020, 13, 573. [Google Scholar] [CrossRef] [Scilit]
  43. Combaluzier, W.; Tauveron, N.; Beaughon, M.; Serafino, A. Decision-making matrix for the selection of mixture in ORC application. In Proceedings of the ORC2023-International Seminar on Organic Rankine Cycle Power Systems, Seville, Spain, 4–6 September 2023; p. 71. [Google Scholar]
  44. Yang, Z.; Coquelet, C.; Wu, J.; Tang, N.; Lu, J. Utilizing computational methods to identify low GWP working fluids for ORC systems. In Energy Consumption, Conversion, Storage, and Efficiency; Xu, J., Yang, B., Eds.; IntechOpen: London, UK, 2024. [Google Scholar] [CrossRef] [Scilit]
  45. Taylor, L.; Siwach, S.; Krumdieck, S. Impact of organic Rankine cycle working fluid selection on heat exchanger design and cost. In Proceedings of the 36th New Zealand Geothermal Workshop, Auckland, New Zealand, 24–26 November 2014; p. 26. [Google Scholar]
  46. Klimaszewski, P.; Zaniewski, D.; Witanowski, Ł.; Suchocki, T.; Klonowicz, P.; Lampart, P. A case study of working fluid selection for a small-scale waste heat recovery ORC system. Arch. Thermodyn. 2019, 40, 159–180. [Google Scholar] [CrossRef] [Scilit]
  47. Rony, R.U.; Yang, H.; Krishnan, S.; Song, J. Recent advances in transcritical CO2 (R744) heat pump system: A review. Energies 2019, 12, 457. [Google Scholar] [CrossRef] [Scilit]
  48. Calm, J.M.; Hourahan, G.C. Physical, safety, and environmental data for current and alternative refrigerants. In Proceedings of the 23rd International Congress of Refrigeration (ICR2011), Prague, Czech Republic, 21–26 August 2011; pp. 21–26. [Google Scholar]
  49. Linde Gases, A.G. Refrigerants Environmental Data: Ozone Depletion and Global Warming Potential. Available online: https://static.prd.echannel.linde.com/wcsstore/PT_RES_Industrial_Gas_Store/Attachment/HFOs/Refrigerants%20environmental%20GWPs_tcm310-111483.pdf (accessed on 21 October 2026).
  50. Intergovernmental Panel on Climate Change (IPCC). Errata: Climate Change 2021: The Physical Science Basis-Working Group I Contribution to the Sixth Assessment Report. Version 7 October 2025. Available online: https://www.ipcc.ch/report/ar6/wg1/downloads/report/IPCC_AR6_WGI_Errata.pdf (accessed on 20 November 2026).
  51. Köse, Ö.; Koç, Y.; Yağlı, H. Is Kalina cycle or organic Rankine cycle for industrial waste heat recovery applications? A detailed performance, economic and environment based comprehensive analysis. Process Saf. Environ. Prot. 2022, 163, 21–37. [Google Scholar] [CrossRef] [Scilit]
  52. Dincer, I.; Eroğlu, İ.; Öztürk, M. Türkiye Için Hidrojen Teknolojileri Yol Haritası [Hydrogen Technologies Roadmap for Türkiye]; Hidrojen Teknolojileri Derneği Yayınları: Istanbul, Türkiye, 2021. [Google Scholar]
  53. Köse, Ö.; Koç, Y.; Yağlı, H. Energy, exergy, economy and environmental (4E) analysis and optimization of single, dual and multi-cycle configurations of the power systems: Rankine Cycle/Kalina Cycle, driven by a gas turbine. Energy Convers. Manag. 2021, 227, 113604. [Google Scholar] [CrossRef] [Scilit]
  54. Srivastava, M.; Sarkar, J.; Sarkar, A.; Maheshwari, N.K.; Antony, A. Thermo-economic feasibility study to utilize ORC technology for waste heat recovery from Indian nuclear power plants. Energy 2024, 298, 131338. [Google Scholar] [CrossRef] [Scilit]
  55. Cao, Y.; Dhahad, H.A.; Togun, H.; Hussen, H.M.; Anqi, A.E.; Farouk, N.; Issakhov, A. Exergy, exergoeconomic and multi-objective optimization of a clean hydrogen and electricity production using geothermal-driven energy systems. Int. J. Hydrogen Energy 2022, 47, 25964–25983. [Google Scholar] [CrossRef] [Scilit]
  56. Salmachi, A.; Hosseini, T.; Shaikh, R.A.; Dinovitser, A.; Abbott, D. Techno-economic assessment of hydrogen pipe storage in decommissioned wellbores sourced from surplus renewable electricity. Int. J. Hydrogen Energy 2022, 47, 23710–23720. [Google Scholar] [CrossRef] [Scilit]
  57. Konur, O.; Korkmaz, S.A.; Erdogan, A.; Arslan, M.; Yilmaz, C. Thermoeconomic opti-mization of an ORC system utilizing main engine and cargo oil pump turbine heat. Energy Sources Part A 2026, 48, 2734257. [Google Scholar] [CrossRef] [Scilit]
  58. Zhang, J.; Hu, X.; Wu, D.; Huang, X.; Wang, X.; Yang, Y.; Wen, C. A comparative study on design and performance evaluation of organic Rankine cycle (ORC) under different two-phase heat transfer correlations. Appl. Energy 2023, 350, 121724. [Google Scholar] [CrossRef] [Scilit]
  59. Mosaffa, A.H.; Mokarram, N.H.; Farshi, L.G. Thermo-economic analysis of combined different ORCs geothermal power plants and LNG cold energy. Geothermics 2017, 65, 113–125. [Google Scholar] [CrossRef] [Scilit]
  60. Ghaebi, H.; Parikhani, T.; Rostamzadeh, H. A novel trigeneration system using geothermal heat source and liquefied natural gas cold energy recovery: Energy, exergy and exergoeconomic analysis. Renew. Energy 2018, 119, 513–527. [Google Scholar] [CrossRef] [Scilit]
  61. El-Emam, R.S.; Dincer, I. Exergy and exergoeconomic analyses and optimization of geothermal organic Rankine cycle. Appl. Therm. Eng. 2013, 59, 435–444. [Google Scholar] [CrossRef] [Scilit]
  62. Valencia, G.; Duarte, J.; Isaza-Roldan, C. Thermoeconomic analysis of different exhaust waste-heat recovery systems for natural gas engine based on ORC. Appl. Sci. 2019, 9, 4017. [Google Scholar] [CrossRef] [Scilit]
  63. Al-Dulaimi, B.M.; Bayat, M.; Tekir, M. Energy, exergy, and thermoeconomic analysis of a natural gas combined power plant. J. Therm. Anal. Calorim. 2025, 150, 1869–1885. [Google Scholar] [CrossRef] [Scilit]
  64. Zhang, Y.; Ma, S.; Yue, W.; Tian, Z.; Yang, C.; Gao, W. Energy, exergy, economic and environmental (4E) evaluation of a solar-integrated energy system at medium–high temperature using CO2 as the parabolic trough collector (PTC) working medium. Energy Convers. Manag. 2023, 296, 117683. [Google Scholar] [CrossRef] [Scilit]
  65. Clean Hydrogen Partnership. Hydrogen Cost and Sales Prices. H2Valleys. Available online: https://h2v.eu/analysis/statistics/financing/hydrogen-cost-and-sales-prices (accessed on 4 August 2026).
  66. Naveiro, M.; Gómez, M.R.; Arias-Fernández, I.; Baaliña Insua, Á. Energy, exergy, economic and environmental analysis of a regasification system integrating simple ORC and LNG open power cycle in floating storage regasification units. Brodogradnja 2023, 74, 39–75. [Google Scholar] [CrossRef] [Scilit]
  67. Bossel, U. Well-to-Wheel Studies, Heating Values, and the Energy Conservation Principle; European Fuel Cell Forum: Lucerne, Switzerland, 2003. [Google Scholar]
  68. Chiesa, P.; Consonni, S.; Kreutz, T.; Williams, R. Co-production of hydrogen, electricity and CO2 from coal with commercially ready technology. Part A: Performance and emissions. Int. J. Hydrogen Energy 2005, 30, 747–767. [Google Scholar] [CrossRef] [Scilit]
  69. Bruno, R.; Ferraro, V.; Cristaudo, A.; Bevilacqua, P. A novel system based on a series of ORCs to recover cryogenic energy from the LNG regasification process for power and freshwater production. J. Clean. Prod. 2024, 469, 143172. [Google Scholar] [CrossRef] [Scilit]
  70. Sun, M.; Huang, X.; Hu, Y.; Lyu, S. Effects on the performance of domestic gas appliances operated on natural gas mixed with hydrogen. Energy 2022, 244, 122557. [Google Scholar] [CrossRef] [Scilit]
  71. Islam, A.; Yoo, Y.; Girard, F. Evaluating the safety and performance of hydrogen-natural gas blends in residential and commercial appliances–testing outcomes and gap analysis. Int. J. Hydrogen Energy 2025, 147, 149876. [Google Scholar] [CrossRef] [Scilit]
  72. Daniarta, S.; Imre, A.R. Cold energy utilization in LNG regasification system using organic Rankine cycle and trilateral flash cycle. Period. Polytech. Mech. Eng. 2020, 64, 342–349. [Google Scholar] [CrossRef] [Scilit]
  73. Li, Y.; Li, Z.; Zhang, H.; Zhang, J.; He, X.; Qiao, Y.; Yu, Z. Comparative exergy analysis of series and parallel dual-pressure auto-cascade organic Rankine cycles. Processes 2024, 12, 2872. [Google Scholar] [CrossRef] [Scilit]
  74. Dutta, A.; Karimi, I.A.; Farooq, S. Economic feasibility of power generation by recovering cold energy during LNG (liquefied natural gas) regasification. ACS Sustain. Chem. Eng. 2018, 6, 10687–10695. [Google Scholar] [CrossRef] [Scilit]
  75. Bao, J. Organic Rankine cycle for recovery of liquefied natural gas (LNG) cold energy. In Organic Rankine Cycle Technology for Heat Recovery; Wang, E., Ed.; IntechOpen: London, UK, 2018; pp. 149–191. [Google Scholar] [CrossRef] [Scilit]
  76. Naveiro, M.; Romero Gómez, M.; Arias-Fernández, I.; Baaliña Insua, Á. Thermodynamic and economic analyses of zero-emission open loop offshore regasification systems integrating ORC with zeotropic mixtures and LNG open power cycle. Energies 2022, 15, 8622. [Google Scholar] [CrossRef] [Scilit]
  77. Li, C.; Lu, X.; Zhang, W.; Yu, H.; Liu, J.; Li, S. Optimization and analysis of an LNG cold energy power generation model with different multi-energy complementary systems. Energy Proc. 2024, 40. [Google Scholar]
  78. Marchiori, G.; Giudici, M.; Ruffato, G.; Astolfi, M. Cold energy recovery in LNG plants with organic Rankine cycle. In Proceedings of the 7th International Seminar on ORC Power Systems, Seville, Spain, 4–6 September 2023; pp. 626–635. [Google Scholar] [CrossRef] [Scilit]
  79. Bruno, R.; Ferraro, V.; Barone, P.; Bevilacqua, P. Energy and exergy analyses of an innovative heat recovery system from the LNG regasification process in green ships. Clean Technol. 2024, 6, 826–851. [Google Scholar] [CrossRef] [Scilit]
  80. Shingan, B.; Singh, D.P.; Singh, V.P. Integrated LNG cold energy recovery through organic Rankine cycle, Kalina, direct expansion cycle, and Brayton cycles for enhanced sustainable power generation and economic feasibility. Environ. Prog. Sustain. Energy 2026, 45, e70329. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.