Thermo-Hydraulic Assessment of Water-Oil Hybrid Cooling for a Cylindrical Battery Module

,
and
Department of Mechanical Engineering, Dong-A University, 37 Nakdong-Daero 550, Saha-gu, Busan 49315, Republic of Korea
*
Author to whom correspondence should be addressed.
†
These authors contributed equally to this work.
This article belongs to the Special Issue New Challenges in Thermodynamics

Abstract

Water-oil hybrid cooling combines indirect water cooling with dielectric immersion, but its thermal benefits must be assessed alongside the hydraulic demand of both coolant circuits. This study evaluates a 10S6P module of 60 cylindrical 21700 cells under a 5C discharge rate. A three-dimensional transient model couples fluid flow and heat transfer with the multi-scale, multi-domain Newman-Tiedemann-Gu-Kim formulation, informed by earlier cell-specific calibration and 3C thermal validation. Serpentine and parallel water cooling are compared before introducing static or forced Pitherm 150B immersion, baffles, and oil flow rates of 1, 3, and 5 L/min. Water flow is fixed at 3 L/min, with initial and inlet temperatures of 25 °C. Parallel cooling requires 91.3% less hydraulic power than serpentine cooling. At an oil flow rate of 3 L/min, forced immersion reduces the maximum temperature from 38.13 °C to 33.84 °C and the temperature spread from 10.95 K to 7.45 K relative to static immersion. Baffles further reduce these values to 32.56 °C and 5.88 K, while increasing the oil-side heat transfer coefficient by 32.3%. A comprehensive performance index (CPI), combining temperature rise, temperature spread, and total water-plus-oil hydraulic power with a penalty exponent of 1/3, increases by 16.6% with baffle integration. Increasing baffled oil flow from 1 to 5 L/min lowers the maximum temperature from 34.75 °C to 31.62 °C and the temperature spread from 7.56 K to 5.14 K, but increases the total hydraulic power 25.9-fold. Among the tested flow rates, the highest CPI, 1.467 relative to the parallel-cooling reference of unity, occurs at 1 L/min. For the investigated module, baffle-guided immersion reduces predicted temperatures at an increased hydraulic cost. Operating-point preferences depend on the temperature objectives and CPI weighting.

1. Introduction

High-rate operation of lithium-ion battery modules in electric vehicles requires effective control of both peak temperature and temperature nonuniformity [1,2,3]. The thermal response of a cell reflects irreversible electrochemical losses, resistive heating, and reversible heat associated with the electrode reactions [4,5,6]. Within a densely packed module, spatial variations in heat removal can lead to unequal cell temperatures even when the imposed electrical load is uniform. Such differences can lead to divergence in cell capacity and state of charge, making temperature uniformity relevant to the performance of the entire pack [7,8,9,10]. Therefore, battery cooling must address the spatial distribution of temperature as well as the magnitude of the temperature rise, while accounting for the hydraulic power required to circulate the coolant.
Indirect liquid cooling removes heat from the battery via a solid cooling structure and a confined coolant circuit [11,12,13,14]. Its performance depends on the thermal contact with the cells, the conduction path through the structure, and the internal flow arrangement. A serpentine channel carries the supplied flow through a continuous passage, whereas parallel channels divide the total flow among several branches. These arrangements consequently differ in local velocity, coolant warming, and flow resistance. Ali et al. [15] recently compared serpentine, parallel, and combined parallel/counter-flow layouts using numerical simulations and experimental validation, demonstrating the importance of assessing temperature distributions together with pumping demand. Their findings also emphasize that channel selection is specific to the module geometry and operating conditions; thermal performance alone does not establish the preferred architecture.
Single-phase immersion cooling provides an additional route for heat transfer by bringing an electrically insulating liquid into direct contact with the cell surfaces. This larger wetted area can complement the limited contact regions of an indirect cooling structure [16,17,18]. Dubey et al. [19] directly compared immersion and cold plate cooling for a module of cylindrical 21700 cells, examining cell temperatures, temperature gradients, and pressure drop across different discharge rates and flow conditions. Jithin and Rajesh [20] reported comparable thermal performance for mineral oil and an engineered dielectric fluid, with the engineered fluid requiring 76.43% less pumping power at a mass flow rate of 0.05 kg/s. Experimental work by Chandrasekaran et al. [21] further demonstrated the influence of flow conditions and conductive cooling features on the performance of single-phase immersion. Tai et al. [22] experimentally compared Therminol D-12, Pitherm 150B and BOT 2100 in a 5S7P 21700 module, further highlighting the need to assess coolant properties together with operating conditions. These studies establish immersion cooling as a promising approach whose effectiveness depends on the combined selection of fluid, geometry, and operating point.
The distinction between stationary and circulating immersion liquid is particularly important when evaluating a hybrid system. A stationary liquid can absorb heat and redistribute it toward cooled surfaces, whereas imposed circulation additionally transports sensible heat out of the module. In experiments with transformer oil, Wang et al. [23] identified different thermal responses under static and dynamic immersion conditions and showed that the inlet/outlet arrangement strongly affected temperature uniformity. At a larger scale, Lu et al. [24] investigated a 190-cell 21700 module and found that inlet configuration, coolant flow rate, and cell spacing jointly influenced thermal performance and pressure drop. These findings indicate that increasing flow rate and improving its spatial distribution are related design choices, with consequences that must be evaluated for the particular module.
Coupling immersion cooling with an indirect liquid circuit provides a means to combine distributed contact with a dedicated heat removal path. Previous research has already established several forms of this coupling. Sadeh et al. [25] investigated a hybrid direct/indirect system for 21700 cells using HFE-7100 and water, including the effects of parallel and counter-flow arrangements under a highway fuel-economy condition. Zou et al. [26] coupled static immersion with cooling tubes to provide heat removal without requiring a separate circulating immersion loop. More recently, Dai et al. [27] examined immersion coupled with an S-type water-cooling tube, studying structural and operating parameters under demanding environmental conditions. Together, these contributions support the physical rationale for combining cooling paths and motivate a closer assessment of the additional benefit and hydraulic cost of actively circulating the immersion liquid.
Flow-guiding structures provide another means of improving immersion cooling, particularly when the unmodified enclosure distributes coolant unevenly among the cells. Gao et al. [28] combined experiments and simulations to compare static and forced immersion conditions and several baffle designs, explicitly considering the balance between heat transfer and pressure loss. Le and Lee [29] examined cell arrangement, inlet/outlet routing, baffle geometry, and coolant selection in a 5S7P immersion-cooled 21700 module. Recent work by Choi et al. [30] used computational fluid dynamics and an artificial neural network to optimize perforated baffles in an immersion-cooled 21700 module. Yang et al. [31] introduced gradient-perforated plates and segmented baffles, showing that excessive baffle height could offset thermal gains by increasing hydraulic resistance and causing unfavorable flow redistribution. This evidence makes clear that the value of a baffle depends on how effectively it directs coolant toward thermally disadvantaged regions relative to the additional pumping demand it creates.
For a hybrid water-oil module, these developments motivate a comparison linking the choice of indirect channel layout to the subsequent addition of immersion cooling and internal flow guidance. The relevant design decision concerns the incremental temperature reduction and improvement in uniformity obtained at each stage of modification. A consistent assessment requires common battery geometry, electrical loading, and thermal reference conditions, together with separate accounting of the two coolant circuits. In particular, total hydraulic pumping power must include both water and oil circulation. Heat transfer rates through the cooling paths also provide a common physical measure for comparing stationary liquid and flowing coolant, for which convective coefficients can be defined.
The present study develops a three-dimensional numerical model of a 10S6P module comprising 60 cylindrical 21700 cells and evaluates its cooling performance during a 5C discharge rate. Battery heat generation is described using the multi-scale, multi-domain Newman-Tiedemann-Gu-Kim (MSMD-NTGK) framework, informed by cell-specific calibration and the 3C thermal validation reported in our earlier work [32]. The comparison begins with serpentine indirect cooling (SIC) and parallel indirect cooling (PIC). The parallel arrangement is then combined with stationary Pitherm 150B oil-immersion (PHC-SI) and forced-flow oil-immersion (PHC-FI). This sequence establishes the performance of the indirect circuit and the additional thermal response associated with the immersion region under the same battery loading and inlet-temperature conditions.
The selected forced-flow hybrid arrangement is subsequently modified by adding baffles to the immersion region, yielding parallel-channel hybrid cooling with baffled forced-flow immersion (PHC-FI-B). The water and oil inlets are located at opposite ends of the module in both forced-flow hybrid configurations, so their comparison evaluates the baffle modification within this common inlet arrangement. Water flow is maintained at 3 L/min, divided equally among three parallel channels, while oil flow in PHC-FI-B is varied between 1, 3, and 5 L/min. The stationary-oil case provides a baseline governed by heat conduction and transient thermal storage, with buoyancy excluded. Maximum battery temperature, temperature spread, and cooling path heat transfer rates are assessed alongside coolant heat transfer coefficients, Nusselt numbers, and the pressure losses and hydraulic powers of the circulating circuits.
Hybrid liquid cooling and baffle-guided immersion are established approaches [25,26,27,28,29,30,31]. The contribution here is a configuration-specific thermo-hydraulic assessment of a 10S6P 21700 module under prescribed 5C loading. It links the comparison of indirect channel layouts with analyses of immersion mode, baffle integration, and oil flow rate. Thermal responses are assessed alongside circuit energy balances and total water-plus-oil hydraulic pumping power. A common PIC reference and CPI-weighting sensitivity analysis identifies how performance preferences depend on the hydraulic penalty. The findings support selection among the tested configurations and operating points, subject to the reported geometry and modeling assumptions.
The remainder of this paper is organized as follows. Section 2 presents the simulation model, battery heat generation model, governing equations, boundary conditions, and data reduction methods, along with mesh independence and thermal model validation. Section 3 compares the thermo-hydraulic performance of single- and hybrid-cooling configurations, followed by analyses of baffle integration and oil flow rate in the selected hybrid configuration. Finally, Section 4 summarizes the principal findings and their implications for the thermal management of cylindrical battery modules.

2. Model and Methodology

2.1. Simulation Model

A three-dimensional numerical model is developed for a 10S6P battery module consisting of 60 cylindrical 21700-type lithium-ion cells. The electrical configuration comprises ten series-connected groups of six parallel-connected cells. The cell geometry and spatial arrangement are retained across the five cooling configurations to provide a common basis for evaluating the cooling architecture under a 5C discharge rate. Each cell has a nominal capacity of 4.80 Ah and a nominal voltage of 3.64 V. Its principal electrical and physical specifications, including dimensional tolerances, are summarized in Table 1. The computational domains comprise the heat-generating battery cells, the aluminum cooling structures, and the coolant regions associated with each configuration.
Table 1. Electrical and physical specifications of the 21700-type battery cell [32].
As shown in Figure 1a, in the serpentine indirect cooling (SIC) configuration, water circulates through a continuous serpentine passage within the aluminum cooling structure positioned between the cell rows. The curved structure follows the cylindrical cell arrangement, providing a conductive path from the batteries to the internal water channel. Water enters through a single inlet, follows the successive turns of the serpentine route, and leaves through a single outlet. Heat is transferred from the cells through the solid cooling structure and subsequently to the circulating water, with the channel walls separating the water from direct contact with the battery surfaces.
Figure 1. Modeling of different battery cooling configurations: (a) Serpentine-channel indirect cooling (SIC), (b) Parallel-channel indirect cooling (PIC), and (c) Parallel-channel hybrid cooling with static immersion (PHC-SI).
The parallel indirect cooling (PIC) configuration employs three parallel water-cooling channels distributed across the same cell array, as illustrated in Figure 1b. Each channel has an inlet and an outlet at opposite ends of the module, and the total water flow is divided equally among the three branches. The conformal aluminum structures transfer heat from the adjacent cells to the water flowing inside the channels. Therefore, SIC and PIC provide two indirect cooling arrangements with different water-flow paths, enabling comparison of their temperature distributions and hydraulic requirements before the addition of immersion cooling.
Parallel-channel hybrid cooling with static immersion (PHC-SI) combines the PIC water circuit with a surrounding region of Pitherm 150B oil, as demonstrated in Figure 1c. The oil contacts the exposed cell surfaces, providing an additional medium for heat exchange between the cells and the surrounding cooling structure. This immersion region has no imposed oil through-flow, while water continues to circulate through the three parallel channels. Because buoyancy is excluded in the present model, oil motion is not generated by temperature differences. Heat transport within the stationary oil is consequently conductive, and its transient energy balance includes thermal storage.
As shown in Figure 2, Parallel-channel hybrid cooling with forced-flow immersion (PHC-FI) retains the three-channel indirect water circuit and introduces a separate circulating Pitherm 150B oil circuit. Water enters at the left end of the module and exits at the right, whereas oil enters through the lower-right inlet and leaves through the upper-left outlet. The circuits thus have opposed overall inlet-to-outlet directions. Within the immersion region, oil is distributed along the lower passage and flows from bottom to top through passages with a nominal spacing of 1 mm adjacent to the battery surfaces. Direct contact between the moving oil and the cell surfaces enables heat exchange along these narrow passages. The warmed oil is collected in the upper passage and directed toward its outlet, providing an additional circulating heat-removal path alongside indirect water cooling. Table 2 summarizes the key geometrical parameters of the battery module and cooling configurations, including the cell arrangement, water channels, oil-immersion passages, plenums, and baffles.
Figure 2. Modeling of parallel-channel hybrid cooling with forced-flow immersion (PHC-FI).
Table 2. Key geometrical parameters of the battery module and cooling configurations.
The two coolants occupy hydraulically separate domains and exchange heat with the battery cells and cooling structures through the coupled thermal field. This model framework permits comparisons between the two indirect channel arrangements and between hybrid systems with stationary and circulating immersion oil. Battery heat generation and the governing equations are described in Section 2.2, while the operating conditions and boundary conditions are specified in Section 2.3.

2.2. Battery Heat Generation Model and Governing Equations

Battery heating is evaluated using the multi-scale multi-domain (MSMD) framework with the Newman-Tiedemann-Gu-Kim (NTGK) electrochemical submodel. The formulation and cell-specific calibration follow our earlier work on Samsung INR21700-48X cells [32]. Each cell is represented by an effective active domain with anisotropic thermal conductivity. The MSMD equations determine the cell-scale temperature and electric potential fields, while the NTGK relations provide the electrochemical current-transfer and heat-source terms from the measured discharge response [32,33].
The transient energy balance within the active cell material is expressed as [32,33]
ρ b c p ,   b ∂ T ∂ t = ∇ · k b ∇ T + q ˙ b
where ρb is the effective cell density, cp,b is its specific heat capacity, kb is the thermal conductivity tensor, and q ˙ b is the volumetric heat generation rate in W/m3. Temperature and time are denoted by T and t, respectively. The two potential fields follow [32,33]:
∇ · σ pos ∇ φ pos = − j
∇ · σ neg ∇ φ neg = j
where the subscripts pos and neg identify the effective positive and negative electronic phases; σ and φ denote their electrical conductivities and potentials. The quantity j is the volumetric current-transfer rate in A/m3. The present formulation describes normal discharge, with internal-short-circuit and thermal-abuse source terms set to zero.
The NTGK closure links current transfer to the difference between the fitted reference voltage and the local phase-potential difference [32,33]:
j = C N C ref V a Y D , T U ( D , T ) − ( φ pos − φ neg )
In this relation, CN is the nominal cell capacity in Ah, Cref is the reference capacity associated with parameter identification, and Va is the active volume of one cell. The reference-voltage function U and conductance function Y depend on temperature and the dimensionless depth of discharge, D. The latter is obtained by integrating the current-transfer rate [32,33]:
D = D 0 + V a 3600 C N ∫ 0 t j t dt
The initial depth of discharge is D0, which is zero for a fully charged cell. The factor 3600 converts capacity from ampere-hours to ampere-seconds, and D is expressed as a fraction rather than a percentage.
The fitted functions use fifth-order polynomials in depth of discharge with temperature corrections [32,33]:
U D , T = ∑ n = 0 5 a n D n − C 2 T − T ref
Y D , T = ∑ n = 0 5 b n D n exp − C 1 1 T − 1 T ref
where the coefficients an and bn define the discharge-dependent response, whereas C1 and C2 describe its temperature correction. Both T and the calibration reference temperature Tref are expressed in kelvin when evaluating these functions.
The heat source combines dissipation in the two electronic phases with electrochemical reaction heating [32,33]:
q ˙ b = σ pos ∇ φ pos 2 + σ neg ∇ φ neg 2 + q ˙ ech
q ˙ ech = j U − φ pos − φ neg − T ∂ U ∂ T D
The squared-gradient terms in Equation (8) represent Joule heating. Within Equation (9), the voltage-loss term accounts for irreversible polarization heating, and the temperature-derivative term gives the reversible entropic contribution. The derivative is evaluated at a fixed depth of discharge. Depending on its sign, the entropic term can increase or reduce the net heat source. The heat generation rate in watts for a cell’s active region is obtained by integrating q ˙ b over Va.
The coefficients reported in our previous study were identified from voltage-time measurements at 0.5C, 1C, 1.5C, 2C, 2.5C and 3C for the same 21700 cell, under natural convection at an ambient temperature of 25 °C [32]. They are reproduced below for traceability, as presented in Table 3. The nominal capacity of 4.8 Ah makes 5C equivalent to 24 A per cell. A common cell parameterization and nominal discharge rate are used across the cooling configurations, and the experimental basis for the thermal model is discussed in Section 2.5.
Table 3. Cell-specific NTGK coefficients reported by Le and Lee [32].
Water and Pitherm 150B oil are represented as incompressible Newtonian fluids with constant thermophysical properties. Neglecting buoyancy, the conservation equations for each coolant are [32,33]
∇ · u → = 0
ρ c ∂ u → ∂ t + u → · ∇ u → = − ∇ p + μ ∇ 2 u →
ρ c c p , c ∂ T c ∂ t + u → · ∇ T c = k c ∇ 2 T c
where ρc, μ, cp,c, kc, u → , p and Tc denote coolant density, dynamic viscosity, specific heat capacity, thermal conductivity, velocity, pressure, and temperature, respectively. For stationary oil, u → = 0, and the energy equation reduces to transient conduction.

2.3. Boundary Conditions and Data Reduction

The cooling configurations are assessed under a common 5C discharge condition, with battery heat generation modeled as a prescribed volumetric source of 639,564.6756 W/m3. This value was derived from the U-Y formulation within the MSMD-NTGK model, as described in Section 2.2, and was applied to the battery-cell domains across all cooling configurations. The transient temperature response is examined over a 720 s comparison interval. The battery cells, cooling components, and coolant domains are initialized at 25 °C, and the inlet temperature of each circulating coolant is maintained at 25 °C. These common thermal conditions provide a consistent basis for comparing the effects of cooling architecture, baffle integration, and oil flow rate.
The circulating coolants are supplied through prescribed mass flow inlet boundaries. The required mass flow rates are obtained from the specified volumetric rates using the constant densities in Table 4. For PIC, the total water flow rate of 3 L/min is divided equally among three parallel cooling channels, corresponding to 1 L/min per channel. The SIC configuration receives 3 L/min through its serpentine flow path. The parallel water circuit in PHC-SI, PHC-FI, and PHC-FI-B maintains a total flow rate of 3 L/min. For the reference forced-immersion cases, oil is supplied independently at 3 L/min; the oil flow rate study considers 1, 3, and 5 L/min while maintaining the water flow rate at 3 L/min.
Table 4. Thermophysical properties of the materials used in the simulations [32].
Reynolds numbers were evaluated using the cross-sectional mean velocity, hydraulic diameter, and constant fluid properties. For the parallel water channels, the velocity was based on 1 L/min per branch, whereas the full 3 L/min passed through the continuous SIC flow path. Using the internal fluid cross-section of 3 × 68 mm gives a nominal hydraulic diameter of 5.75 mm. With the water properties in Table 4, the corresponding nominal Reynolds numbers are approximately 470 for the parallel branches and 1400 for SIC. For the 10 mm oil ports, the nominal Reynolds number ranges from approximately 264 to 1320 over the flow rate range of 1–5 L/min. Based on the nominal Reynolds numbers, a laminar viscous model was adopted for all fluid domains without a turbulence closure.
Each open coolant outlet is assigned a pressure-outlet condition of 0 Pa gauge relative to the atmospheric operating-pressure reference. All stationary fluid-wetted surfaces, including the battery surfaces, cooling channel walls, and immersion baffles, satisfy the no-slip condition. Heat-transferring solid-fluid interfaces are thermally coupled, with continuity of temperature and normal heat flux. Ideal thermal contact is assumed between contacting solid components, enabling heat to transfer from the cells to the cooling structure and subsequently to the coolant.
For PHC-SI, the immersion region is closed to through-flow, with no oil inlet or outlet. Buoyancy effects are excluded, and no imposed circulation is applied. Therefore, the oil remains stationary. Heat exchange within this region is governed by conduction and transient sensible-energy storage. For PHC-FI and PHC-FI-B, the oil inlet is located at the opposite end of the module from the water inlets. In PHC-FI-B, the stationary baffle arrangement redirects the immersion flow without changing the prescribed reference inlet temperature or circuit flow rates.
External module walls, apart from the coolant openings, are treated as adiabatic, so heat exchange with the surrounding environment is excluded. Water and Pitherm 150B oil are represented as single-phase, incompressible Newtonian fluids. The density, specific heat capacity, thermal conductivity, and viscosity are held constant at the values listed in Table 4. The battery is represented using an anisotropic thermal conductivity tensor, with the listed components corresponding to the model coordinate directions. Its thermophysical values follow those reported for the same cell in our previous study [32].
The constant fluid properties in Table 4 represent a modeling simplification. Manufacturer data for Pitherm 150B indicate conductivity variation below 1% between 20 and 40 °C, whereas dynamic viscosity decreases from approximately 0.00632 kg/(m·s) at 25 °C (interpolated) to 0.00391 kg/(m·s) at 40 °C. Viscosity variations may affect flow distribution, interfacial heat transfer, and viscous pressure losses. Consequently, temperature, pumping power, and CPI predictions remain conditional on this assumption. Neither the heat source nor CPI-weighting sensitivity analysis quantifies these coupled effects. Future work will assess temperature-dependent properties for both coolants over their actual operating temperature ranges.
All simulations employed the double-precision, pressure-based solver in Ansys Fluent 2025 R2. Pressure-velocity coupling was treated using SIMPLE. Gradients were reconstructed with the least-squares cell-based method; pressure interpolation used the second-order scheme, and momentum and energy convection used second-order upwind discretization. First-order implicit temporal discretization was applied. Hybrid Initialization was used, with initial battery and coolant temperatures set to 25 °C, and under-relaxation factors of 0.3 for pressure, 0.7 for momentum, and 1.0 for energy were applied. Within each time step, the flow and energy equations were solved iteratively using the segregated algorithm with conjugate heat transfer across all fluid-solid interfaces.
The nominal 5C discharge was simulated for 720 s using a fixed time step of 5 s (144 time steps). Time-step sensitivity was evaluated for PHC-FI-B at 5 L/min oil and 3 L/min water at t = 720 s using time steps of 1, 3, and 5 s, with the 1 s case serving as the reference. Between the 1 s and 5 s solutions, the absolute difference in maximum battery temperature was 0.08 °C, while the relative deviations in maximum module temperature difference and oil circuit pressure drop remained below 1.78% (0.09 °C) and 0.14%, respectively. Accordingly, the 5 s time step was retained as an accuracy-cost compromise for all subsequent simulations. Twenty solver iterations were performed per time step. Automatic residual-based termination was disabled by selecting None in the residual-monitor settings while recording full residual histories. Inspection of these histories confirmed that the scaled residuals fell below 10−4 for the continuity and momentum components and below 10−6 for energy by the end of each time step.
To assess the temperature uniformity across the battery module, the maximum spatial temperature gradient ΔTmax is determined using the following relation [29,32]:
Δ T max ( t ) = T max , battery ( t ) − T min , battery ( t )
where Tmax,battery and Tmin,battery represent the peak and lowest temperatures recorded throughout the entire cell domain, respectively.
The average heat transfer coefficient (HTC) characterizing the thermal interaction between the battery surface and the cooling medium is quantified as [29,32]
HTC = Q conv , coolant A ( T mean , battery −   T mean , coolant )
where A represents the effective heat transfer area. The bulk temperature of the fluid Tmean,coolant is evaluated as the arithmetic mean of the inflow and outflow temperatures [29,32]:
T mean , coolant   =   T inlet , coolant   +   T outlet , coolant 2
For circulating coolants with a positive mass flow rate, the net advective heat transfer rate is evaluated using mass-flow-weighted inlet and outlet temperatures:
Q ˙ adv , i = m ˙ i c p , i ( T out , i − T in , i )
For multiple ports, the individual enthalpy inflows and outflows are summed. The net heat input to the oil from its surrounding solids is obtained by integrating the signed normal heat flux over all oil-solid interfaces, with heat flux defined as positive into the oil. The transient oil energy balance is
Q ˙ wall , o = d E o dt + Q ˙ adv , o + Q ˙ cond , port , o
For constant thermophysical properties, the sensible thermal energy stored in the oil relative to its initial temperature is
E o = ρ o c p , o V o T ¯ o , V − T 0
where T ¯ o , V denotes the volume-averaged oil temperature, Vo is the oil volume, and T0 = 25 °C is the common initial temperature. The port-conduction term represents net outward conductive heat transfer through the oil inlet and outlet.
In PHC-SI, the oil domain has no inlet or outlet, and buoyancy is excluded. Therefore, both port terms vanish, and Equation (17) reduces to
Q ˙ wall , o = d E o dt
A nonzero net interfacial heat input consequently changes the energy stored in the stationary oil. Heat transfer evaluated over only the battery-oil interface represents internal exchange; it does not, by itself, quantify external heat removal.
For the entire computational domain, the external module walls are adiabatic, while the coolant openings remain energy-transfer boundaries. The corresponding whole-module thermal balance is
Q ˙ gen = d E tot dt + Q ˙ adv , w + Q ˙ adv , o + Q ˙ cond , ports
where Q ˙ gen is the total heat generation power of the 60 cells, in watts, obtained by integrating the volumetric heat source over the heat-generating cell domains. Etot includes sensible thermal storage in all modeled solid and fluid regions, including the cells, aluminum structures and baffles where present. The final term is the combined net outward conductive transfer at the water and oil ports. Internal interfacial transfers cancel from the whole-module balance.
To evaluate the convective heat transfer performance relative to pure conduction, the dimensionless Nusselt number Nu is introduced [29,32]:
Nu   =   h D h k coolant
where Dh and kcoolant denote the hydraulic diameter of the flow channel and the thermal conductivity of the coolant, respectively.
To evaluate the hydraulic characteristics of the cooling system, the total coolant pressure drop ΔP across the flow passages is determined by subtracting the outlet pressure from the inlet pressure [29,32]:
Δ P   = P inlet , coolant − P outlet , coolant
Alongside the thermal efficiency indicators, the hydraulic performance is further quantified through the required pumping power Ppump, which is formulated as [14]:
P pump = Δ P A in u in
where Ain signifies the cross-sectional area at the inlet, and uin represents the corresponding uniform inlet velocity of the coolant.

2.4. Mesh Independence Test

A mesh independence test was conducted to assess the sensitivity of the predicted thermal and hydraulic responses to spatial discretization and to select a suitable mesh for subsequent simulations. Meshes were generated using Ansys Fluent Meshing 2025 R2, and three progressively refined meshes, designated Cases 1, 2, and 3, were evaluated for each cooling configuration. As summarized in Table 5, the meshes contained approximately 0.96–1.29 million, 2.05–2.71 million, and 3.80–5.77 million elements for Cases 1, 2, and 3, respectively. The maximum battery temperature (Tmax), maximum temperature difference within the module (ΔTmax), and coolant pressure drop (ΔP) were monitored to evaluate the influence of mesh resolution on both thermal performance and flow resistance.
Table 5. Mesh independence test results across different mesh cases for various BTMS configurations.
All mesh comparisons were performed at a 5C discharge rate, with the battery and coolants initially at 25 °C and the coolant inlet temperatures maintained at 25 °C. For PIC, the total water flow rate was 3 L/min, distributed equally among three cooling channels at 1 L/min per channel. For SIC, a water flow rate of 3 L/min was supplied through the serpentine channel. Both hybrid configurations also used a total water flow rate of 3 L/min, equally divided among three indirect cooling channels. PHC-SI operated without imposed oil circulation (0 L/min), whereas PHC-FI incorporated an additional oil flow rate of 3 L/min. Thus, PHC-FI used separate water and oil flow rates of 3 L/min each. For PHC-FI-B, an additional mesh-refinement assessment was conducted at an oil flow rate of 5 L/min, with the total water flow rate remaining at 3 L/min, evenly divided among the three indirect cooling channels. This highest tested oil flow rate was selected to assess mesh sensitivity in the baffled immersion passages under the most hydraulically demanding operating condition investigated.
Refinement from Case 1 to Case 2 changed ΔTmax by 4.82%, 7.26%, and 5.11% for PIC, SIC, and PHC-SI, respectively. For PHC-FI, Tmax changed by only 0.02 °C, whereas ΔP changed by 5.60%, demonstrating the importance of considering hydraulic responses alongside temperature predictions. Further refinement from Case 2 to Case 3 changed Tmax by 0.06 °C, 0.21 °C, 0.12 °C, and 0.02 °C for PIC, SIC, PHC-SI, and PHC-FI, respectively. The corresponding changes in ΔTmax were 0.05 °C, 0.24 °C, 0.03 °C, and 0.00 °C, with relative deviations of no more than 2.30%. The reported pressure drop deviations were 0.55%, 0.08%, 0.26%, and 0.65%, respectively. For PHC-FI-B at an oil flow rate of 5 L/min, refinement from Case 1 to Case 2 increased Tmax by 0.49 °C, ΔTmax by 10.31%, and oil-side ΔP by 10.08%. Further refinement to Case 3 produced smaller increases of 0.20 °C in Tmax, 0.14 °C in ΔTmax, and 63.57 Pa in ΔP. Relative to Case 3, the latter two differences corresponded to 2.65% and 2.20%, respectively. These results indicate diminishing changes with refinement, although temperature uniformity and hydraulic resistance remained more mesh-sensitive than in the other configurations.
Although some thermal responses varied nonmonotonically with refinement, the differences between Cases 2 and 3 remained small under the operating conditions investigated. Accordingly, Case 2 was selected for all subsequent simulations, comprising 2,271,246 elements for PIC, 2,053,399 elements for SIC, 2,706,673 elements for PHC-SI, 2,096,229 elements for PHC-FI, and 2,135,839 elements for PHC-FI-B. These meshes contained approximately 43–55% fewer elements than Case 3, providing a practical balance between mesh resolution and computational demand. Figure 3 illustrates the computational meshes generated for the five cooling configurations investigated in this study.
Figure 3. Computational meshes for the investigated battery cooling configurations: (a) SIC; (b) PIC; (c) PHC-SI; (d) PHC-FI; and (e) PHC-FI-B.

2.5. Validation of the Battery Thermal Model

The experimental basis for the battery thermal model was established in our previous study [32], which investigated the same commercial Samsung INR21700-48X cylindrical cell used in the present module. The cell has a nominal capacity of 4.8 Ah. The MSMD framework, coupled with the NTGK model, was calibrated using measured voltage-time profiles at discharge rates of 0.5C, 1C, 1.5C, 2C, 2.5C and 3C. These measurements were used to determine the cell-specific NTGK parameter functions U and Y, providing an experimental basis for the electrothermal formulation.
The earlier experiments were performed in a constant temperature and humidity chamber maintained at 25 °C. The cell was charged using a TS3010A-1 power supply (Toyotech Co., Ltd., Incheon, Republic of Korea) and discharged using a TLF1200 electronic load (Toyotech Co., Ltd., Incheon, Republic of Korea) between an initial voltage of 4.2 V and a cut-off voltage of 2.5 V. Temperature and voltage were recorded using a Graphtec GL840 data logger (GRAPHTEC, Yokohama, Japan). Three T-type thermocouples, each with a stated accuracy of ±0.1 °C, were attached to the upper, middle, and lower regions of the cell surface. The measured temperature difference among these locations remained below 1.0 °C during discharge, supporting the use of the middle-surface measurement as a representative temperature for the validation comparison [32].
The MSMD-NTGK thermal model was previously validated experimentally using the same 21700-type cell at a 3C discharge rate [32]. The reported temperature error below 5% applies to that validation condition and cannot be adopted as an error bound for the present 5C simulations. Therefore, applying the model at 5C involves extrapolation beyond the experimentally validated discharge rate. Published high-rate applications provide methodological context [34], but do not establish the predictive accuracy for the present cell at 5C.
To assess the influence of an assumed variation in heat input, an illustrative sensitivity analysis was performed for PIC and PHC-FI-B. The nominal 5C volumetric heat generation rate of 639,564.6756 W/m3 was multiplied by 0.9 and 1.1, with the other prescribed conditions unchanged. The total water flow rate was 3 L/min in both configurations, equally divided among three channels; PHC-FI-B additionally used 3 L/min of oil. Initial battery and coolant temperatures, as well as coolant inlet temperature, were 25 °C. Results were extracted at 720 s. The ±10% range is a prescribed perturbation interval, not an experimentally established estimate of 5C model uncertainty.
Table 6 shows that PIC has a maximum temperature range of 37.06–39.74 °C and a temperature-spread range of 10.08–12.32 °C, corresponding to baseline deviations of ±1.34 °C and ±1.12 °C, respectively. For PHC-FI-B, the corresponding ranges are 31.69–33.18 °C and 5.18–6.34 °C. Relative to its baseline, the maximum temperature changes by −0.87 and +0.62 °C, while the temperature spread changes by −0.70 and +0.46 °C. These are responses to the imposed source perturbations, rather than measured prediction errors.
Table 6. Sensitivity of thermal predictions to the prescribed 5C heat generation rate at 720 s.
The thermal ordering between the two configurations remains unchanged across the three sampled heat source levels. Even the highest-temperature PHC-FI-B case remains 3.88 °C cooler than the lowest-temperature PIC case, with a temperature spread lower by 3.74 °C. This separation supports PHC-FI-B’s comparative thermal advantage across the reported scenarios. This assessment examines the sensitivity of the two cooling configurations to the prescribed heat generation amplitude and does not constitute experimental validation at 5C. Therefore, same-cell thermal measurements at 5C are identified as a priority for future work, enabling direct assessment of the absolute temperature predictions and quantification of prediction errors at this discharge rate.

3. Results and Discussion

This section evaluates the thermo-hydraulic performance of the 10S6P battery module under a 5C discharge rate. The analysis progresses from serpentine and parallel indirect cooling to parallel-channel hybrid configurations incorporating static or forced-flow immersion. Subsequent comparisons examine baffle integration and oil flow rate in the selected hybrid configuration. Battery temperature distributions and heat transfer characteristics are assessed alongside circuit pressure losses and combined water-oil hydraulic pumping power. The Comprehensive Performance Index (CPI) provides a common basis for weighing temperature-control benefits against hydraulic demand, supporting the selection of cooling configurations and operating conditions.

3.1. Comparison of the Thermo-Hydraulic Performance of Single- and Hybrid-Cooling Configurations

3.1.1. Serpentine and Parallel Indirect Cooling Configurations

The SIC and PIC configurations were compared under a 5C discharge rate to evaluate how channel arrangement affects thermal regulation and hydraulic demand in the 10S6P cylindrical-cell module. The battery was initially at 25 °C, and water entered the cooling channels at 25 °C. Both configurations received a total volumetric flow rate of 3 L/min. In SIC, the full flow followed a continuous serpentine path; in PIC, it was divided equally among three parallel channels, giving 1 L/min per channel. Therefore, this comparison maintained the same total coolant throughput while changing the routing of the coolant through the module.
As shown in Figure 4a,b, the transient temperature histories show an initial rapid rise, followed by a progressive reduction in the heating rate over the 720 s simulation interval. SIC attained a final Tmax of 36.52 °C, compared with 38.40 °C for PIC, corresponding to a reduction of 1.88 °C. Relative to the common initial temperature of 25 °C, the maximum temperature rises were 11.52 °C and 13.40 °C, respectively. Thus, SIC reduced the maximum temperature rise by approximately 14.0%. The final ΔTmax also decreased from 11.20 °C for PIC to 10.19 °C for SIC, a reduction of 1.01 °C, or approximately 9.0%. The uniformity benefit emerged after the initial transient, as SIC exhibited a slightly larger temperature spread early in the discharge before PIC became less uniform. Therefore, the late-time results indicate that SIC improved both hotspot control and module temperature uniformity at the tested flow rate.
Figure 4. (a) Transient evolution of the maximum battery temperature (Tmax); (b) Transient evolution of the maximum module temperature difference (ΔTmax); (c) Battery temperature contours at the end of discharge for different cooling configurations.
The temperature contours reinforce this comparison, as presented in Figure 4c. On the shared scale of 25.00–38.40 °C, SIC exhibits more extensive green and cyan regions, whereas PIC shows larger orange and red regions across multiple cells. The smaller spatial extent of warm regions in SIC is consistent with its lower Tmax and ΔTmax. Temperature variation remains visible across the array and on individual cell surfaces, reflecting the spatially varying thermal paths from the heat-generating cells to the water-cooled interfaces. The remaining ΔTmax values of approximately 10–11 °C show that substantial spatial gradients persist in both indirect cooling designs.
As shown in Figure 5a, the water-side convective comparison provides further evidence for the thermal difference. SIC yielded an effective HTC of 1920.61 W/(m2·K), whereas PIC yielded 1191.07 W/(m2·K), representing an increase of 61.3%. The corresponding Nu values were 12.44 and 7.71, respectively, also an increase of approximately 61%. These results indicate a higher effective convective heat transfer coefficient at the water-wetted cooling surfaces in SIC. Because Nu normalizes HTC using the hydraulic diameter and coolant thermal conductivity, their closely proportional changes are consistent with a common ratio of hydraulic diameter to coolant thermal conductivity in the data reduction. Under those reference conditions, HTC and Nu provide dimensional and dimensionless descriptions of the same convective enhancement. This enhancement is consistent with the way the total flow is distributed. SIC carries 3 L/min through its single path, whereas each PIC branch carries 1 L/min. For equal channel cross-sections, these flow rates would give SIC approximately three times the mean velocity and Reynolds number of one PIC branch, which can intensify convection in developing and curved flow regions. In addition, the turns in a serpentine channel can promote recirculation and disturb thermal boundary layers, enhancing transport between the near-wall region and the core fluid. Such effects have been reported in experimental and numerical investigations of serpentine water-cooled microchannels [35]. These mechanisms provide a plausible interpretation of the higher HTC observed in the present study.
Figure 5. (a) Water-side heat transfer coefficient (HTC) and Nusselt number (Nu); (b) Coolant pressure drop (ΔP) and hydraulic pumping power (Ppump); (c) Comprehensive performance index (CPI) at α = 1/3 with PIC as the reference configuration.
The thermal advantage of SIC was accompanied by a higher hydraulic requirement. As indicated in Figure 5b, the module pressure drop (ΔP) was 792.43 Pa for SIC and 68.96 Pa for PIC, giving a ratio of approximately 11.49. Because both configurations employed the same total flow rate, the hydraulic pumping power (Ppump), calculated as the product of pressure drop and total volumetric flow rate, followed the same ratio. The corresponding values were 0.03962 W and 0.00345 W, respectively. For PIC, the power calculation accounted for the combined flow of 3 L/min through the three branches. Relative to SIC, PIC reduced the hydraulic pumping demand by approximately 91.3%, while incurring the higher maximum temperature and temperature spread reported above. The pressure drop penalty is consistent with the longer flow path and repeated directional changes in SIC. The full flow traverses the connected passages and bends, so frictional resistance and local turning losses accumulate along the same path. By comparison, PIC distributes the flow among three shorter paths, limiting the flow rate in each branch. These factors provide a physical basis for its lower pressure drop and pumping demand, consistent with the heat transfer and pressure loss trade-off reported for serpentine channels [35]. In absolute terms, the calculated hydraulic power difference was approximately 0.03617 W for the present module. These values quantify the hydraulic power delivered to the fluid across the modeled cooling domain; electrical pump input also depends on pump efficiency and additional external circuit losses. The fixed-flow comparison establishes a thermal-hydraulic trade-off: SIC provides lower Tmax and ΔTmax and higher HTC and Nu, whereas PIC requires less hydraulic power. Performance at equal pumping power requires an explicitly matched operating constraint [36]. These results provide a basis for the subsequent CPI assessment and for evaluating the addition of immersion cooling to the PIC configuration.
The thermo-hydraulic trade-off was assessed using a modified CPI adapted from Yang et al. [31]. The maximum temperature term was expressed using the maximum temperature rise above the common coolant inlet temperature of 25 °C, denoted θ, to avoid the unit dependence of ratios formed from Celsius temperatures. The hydraulic penalty was based on total hydraulic pumping power. Because SIC and PIC both operated at 3 L/min, their pumping power ratio equaled their pressure drop ratio. The modified index was calculated as follows, with subscript 0 denoting PIC and α = 1/3 adopted as the baseline penalty weighting.
CPI i = θ 0 θ i · Δ T max , 0 Δ T max , i P pump , i P pump , 0 α
Under this definition, PIC had a CPI of 1.000, and SIC had a value of 0.567, as presented in Figure 5c. Although SIC reduced Tmax by 1.88 °C and ΔTmax by 1.01 °C, its 11.49-fold higher hydraulic pumping power produced a penalty factor of 2.257 after application of the one-third exponent. The combined thermal gain factor was 1.278, yielding an index below unity. Thus, the thermal improvements of SIC did not compensate for its hydraulic penalty under the chosen weighting. PIC required approximately 91.3% less hydraulic pumping power, supporting its selection as the basis for subsequent hybrid development under the tested conditions. Sensitivity testing preserved this ranking: the CPI of SIC decreased to 0.377 and 0.111 for α = 1/2 and 1, respectively, while PIC remained at 1.000. Direct reproduction of the source article’s Celsius-based temperature term also favored PIC, with scores of 1.000 for PIC and 0.512 for SIC at α = 1/3 [31]. The modified values are retained here so that temperature normalization is independent of the Celsius zero point. The exponent represents an explicit penalty weighting; performance at equal pumping power requires a separately matched operating comparison [36]. Accordingly, PIC was selected as the indirect cooling platform for the hybrid configurations examined in the following section. Its lower hydraulic demand provides a basis for assessing the potential thermal management benefit of direct oil contact with the cells.

3.1.2. Parallel-Channel Hybrid Cooling with Static and Forced-Flow Immersion

The PHC-SI and PHC-FI configurations were compared to evaluate the thermal contribution of oil circulation when combined with parallel-channel indirect cooling in the battery module. Both configurations operated at a 5C discharge rate with a total water flow rate of 3 L/min, equally distributed among three indirect cooling channels at 1 L/min per channel. In PHC-SI, the cells were immersed in Pitherm 150B oil without imposed oil circulation. In PHC-FI, an additional, separate oil stream was supplied through the immersion domain at a flow rate of 3 L/min. The module and fluids were initially at 25 °C, and the inlet temperatures of the actively circulated fluids were maintained at 25 °C. Therefore, the comparison retained the same water-cooling conditions while introducing forced transport in the oil domain.
As shown in Figure 6a,b, the transient temperature histories show similar rapid heating during the initial stage, followed by increasing separation between the two configurations. PHC-FI developed a lower heating rate after this early transient and approached an approximately constant maximum temperature by about 300 s. PHC-SI continued to warm more gradually over a larger part of the 720 s simulation interval. A corresponding distinction is evident in the evolution of ΔTmax: forced immersion limited the growth of the temperature spread earlier, whereas the static configuration continued to develop greater spatial nonuniformity. These histories indicate that the benefit of imposed oil circulation became more pronounced as heat accumulated in the module. At the end of the simulation, Tmax was 38.13 °C for PHC-SI and 33.84 °C for PHC-FI, corresponding to a reduction of 4.29 °C. Relative to the common initial and inlet temperature of 25 °C, the maximum temperature rise decreased from 13.13 °C to 8.84 °C, representing a reduction of approximately 32.7%. The final ΔTmax decreased from 10.95 °C for PHC-SI to 7.45 °C for PHC-FI, an improvement of 3.50 °C, or approximately 32.0%. Thus, under the investigated operating conditions, forced immersion improved both peak-temperature control and module temperature uniformity.
Figure 6. Comparison of the thermal performance of PHC-SI and PHC-FI under 5C discharge: (a) transient evolution of maximum battery temperature; (b) transient evolution of maximum temperature difference; and (c) battery temperature contours for PHC-SI (left) and PHC-FI (right). The total water flow rate is 3 L/min for both configurations, while the oil flow rate is 0 L/min for PHC-SI and 3 L/min for PHC-FI.
The temperature contours support these quantitative observations, as demonstrated in Figure 6c. On the common scale of 25.00–38.13 °C, PHC-SI exhibits extensive orange and red regions across several cells, whereas PHC-FI shows predominantly green and yellow regions with a smaller spatial extent of elevated temperatures. The change extends across much of the array, indicating that the thermal benefit was distributed over the module rather than confined to an isolated cell. Temperature differences remain visible between cell locations and along individual cell surfaces in PHC-FI, consistent with its residual ΔTmax of 7.45 °C. Therefore, forced circulation attenuated, but did not eliminate, the spatial thermal gradients under the investigated conditions.
The observed improvement is consistent with the additional advective heat transfer pathway provided by the circulating oil. Direct liquid contact exposes cell surfaces to an additional cooling medium, extending heat exchange beyond the interfaces available to indirect cooling alone [37,38,39]. In the static bath, the oil can absorb and redistribute heat, but it does not export energy through an imposed oil stream. As the surrounding oil warms, the local temperature difference driving heat transfer from the cells can decrease. In PHC-FI, the imposed flow supplies cooler oil, carries heated fluid away from the cells, and transports absorbed energy toward the outlet. Fluid renewal around the cells can consequently limit localized thermal accumulation.
Relative to PIC, PHC-SI yielded small predicted reductions of 0.27 °C in maximum battery temperature and 0.25 K in temperature spread at 720 s. Using the Case 3 mesh results in Table 5, the corresponding reductions were 0.33 °C and 0.17 K. Therefore, their sign persisted between the two finest mesh levels, although the gain remained only a few tenths of a degree. This check assesses the numerical sensitivity of the comparison within the prescribed model.
The practical significance of these differences remains unverified. Mesh and time-step checks do not quantify all sources of model uncertainty. The reported 3C validation error is not an error bound for the present 5C cases, and the prescribed heat source perturbations did not include PHC-SI or quantify uncertainty in the difference between PIC and PHC-SI. The effects of constant coolant properties and the exclusion of buoyancy also remain unquantified. Accordingly, PHC-SI is retained as a baseline for conductive heat redistribution and storage; a meaningful physical advantage over PIC has not been established.
PHC-FI yielded larger predicted reductions of 4.56 °C and 3.75 K relative to PIC at the tested flow rates. These remain comparisons between configurations. Differences in enclosure geometry and the conduction-only treatment of static oil preclude attributing the full difference between PHC-SI and PHC-FI solely to oil circulation. Therefore, hydraulic power and CPI are assessed alongside the predicted temperatures.
Table 7 presents the oil-domain and whole-module energy balances for PHC-SI and PHC-FI under 5C discharge, with a water flow rate of 3 L/min in both configurations. The analysis distinguishes battery-to-oil interfacial heat transfer, net heat input across all oil-solid interfaces, and energy exported through the coolant openings. These quantities describe different aspects of thermal transport: interfacial rates characterize heat redistribution within the module, whereas advective exports quantify energy transported across its external boundary by circulating coolant.
Table 7. Oil-domain and whole-module energy balances at 720 s under 5C discharge.
In PHC-SI, buoyancy and imposed oil circulation are excluded, so heat transport within the oil occurs by conduction, accompanied by transient sensible energy storage. The battery-to-oil heat transfer rate is 49.687 W, while the net heat input across all oil-solid interfaces is 5.834 W. Their difference implies a net transfer of 43.853 W from the oil to other oil-contacting solids. Thus, the stationary oil acts as a medium for internal heat redistribution and thermal storage, despite having no advective export. The independently estimated oil storage rate is 5.715 W, giving an oil-domain imbalance of 0.119 W, equivalent to 2.04% of the net oil-wall input. Consequently, the nonzero static-oil heat transfer rate should be interpreted as internal conductive heat transfer rather than as energy removed through an oil outlet.
For PHC-FI, oil circulation at 3 L/min provides an additional mechanism to export thermal energy from the module. The net oil-wall heat input is 321.849 W, while the oil advective export is 321.809 W. The estimated oil storage rate is only 0.00131 W, indicating that accumulation contributes little to the reported oil-domain balance over the sampling interval. Including signed oil-port conduction gives a remaining oil-domain imbalance of approximately 0.041 W. Meanwhile, water advective export decreases from 904.817 W in PHC-SI to 591.523 W in PHC-FI, a reduction of 34.63%. This change is consistent with the circulating oil carrying a substantial thermal load directly out of the module and reducing the duty of the indirect water circuit.
For the whole-module balance, the total battery heat generation rate is 930.384 W across both configurations. The calculation includes sensible energy storage in all modeled solid and fluid domains, advective exports of water and oil, and signed conductive transport at the coolant openings. Internal oil-solid exchanges are excluded from the external export sum to prevent double counting. Negative port-conduction values denote net conductive energy input under the outward-positive convention. The resulting global imbalances are 2.00% for PHC-SI and 1.84% for PHC-FI.
The storage rates are independently estimated from volume-averaged temperature changes over 715–720 s, whereas the boundary fluxes are based on 720 s. Therefore, the reported results constitute an approximate assessment of the transient energy balance. The residuals explicitly quantify the remaining nonclosure; they do not establish exact conservation or identify the individual contributions of temporal sampling and numerical error.
As shown in Table 8, the water-circuit pressure drop remained 68.96 Pa for both configurations at a total flow rate of 3 L/min. Its hydraulic pumping power was consequently unchanged at 0.00345 W. PHC-SI required no oil pumping power, whereas PHC-FI incurred an oil-circuit pressure drop of 649.56 Pa at 3 L/min, corresponding to 0.03248 W. Summing the hydraulic powers of the independent circuits yielded 0.00345 W for PHC-SI and 0.03593 W for PHC-FI. Thus, forced immersion increased total hydraulic demand by a factor of 10.42, with oil circulation accounting for 90.40% of the PHC-FI total. This additional demand must be considered alongside its thermal improvements.
Table 8. Comparison of water- and oil-circuit pressure drops and hydraulic pumping powers of PHC-SI and PHC-FI configurations.
The thermo-hydraulic trade-off was evaluated using the CPI, as shown in Figure 7. The index combines the normalized maximum temperature rise above the common inlet temperature of 25 °C and the maximum temperature spread, with a total hydraulic pumping power penalty. PIC was retained as the common reference, with a temperature rise of 13.40 K, a temperature spread of 11.20 K, and a hydraulic pumping power of 0.00345 W. At a penalty exponent of one-third, the calculated CPI values were 1.0439 for PHC-SI and 1.0434 for PHC-FI, compared with 1.0000 for PIC.
Figure 7. Comparison of the comprehensive performance index (CPI) for PHC-SI and PHC-FI at α = 1/3 under 5C discharge, normalized to the PIC reference (CPI = 1). The water flow rate is 3 L/min in both configurations, while the oil flow rates are 0 and 3 L/min for PHC-SI and PHC-FI, respectively.
Therefore, the two hybrid configurations achieved essentially equivalent CPI scores under the adopted weighting. Relative to PHC-SI, PHC-FI produced a combined thermal-benefit factor of 2.1831, almost matching its pumping power penalty factor of 2.1841. The approximately 0.05% difference between their CPI values provides little basis for a practical ranking using the rounded input data. Nevertheless, PHC-FI reduced the maximum battery temperature from 38.13 °C to 33.84 °C and the maximum temperature spread from 10.95 °C to 7.45 °C. These reductions support carrying PHC-FI forward for baffle enhancement when tighter thermal control is prioritized, while PHC-SI remains attractive where minimum pumping demand is the principal objective.
It should be noted that buoyancy was excluded from the oil-domain calculations; consequently, the PHC-SI oil region represents conductive heat redistribution and transient sensible-energy storage. This assumption may underpredict the cooling performance of an unpumped immersion bath and overestimate the benefit of forced circulation. Therefore, the PHC-SI and PHC-FI comparison is conditional on the adopted buoyancy-neglected formulation, and the improvement relative to a naturally convecting bath remains unquantified. The heat source sensitivity analysis does not assess this separate modeling limitation. Future work will examine buoyancy-enabled simulations for both configurations, supported by appropriate oil thermal expansion data and experimental validation of stationary immersion.

3.2. Effect of Baffle Integration on the Thermo-Hydraulic Performance of PHC-FI

The thermal effects of modifying the immersion flow path were evaluated by comparing parallel-channel hybrid cooling with forced-flow immersion (PHC-FI) and parallel-channel hybrid cooling with baffled forced-flow immersion (PHC-FI-B). As illustrated in Figure 8, in PHC-FI-B, two 1 mm-thick baffles were incorporated into the oil domain to guide coolant transport around the cylindrical cells, and the oil supply was directed opposite to the water inlet flow in the indirect cooling circuit. The baffle arrangement in PHC-FI-B was introduced as a representative modification intended to guide oil through the intercell passages, limit bypass flow, and improve coolant coverage. A thickness of 1 mm was prescribed as a fixed geometric parameter; alternative thicknesses and positions were not systematically evaluated. Accordingly, this section examines the thermo-hydraulic effect of the selected arrangement relative to PHC-FI under identical operating conditions. The findings establish the performance of this particular design, while optimization of baffle thickness and placement remains a subject for future investigation. Both configurations were simulated at a 5C discharge rate with a total water flow rate of 3 L/min, equally divided among three parallel channels at 1 L/min per channel, and a separate Pitherm 150B oil flow rate of 3 L/min. The initial battery temperature and coolant inlet temperatures were 25 °C. Therefore, the comparison examines the thermal benefit of the modified immersion layout at the same imposed flow rates.
Figure 8. Modeling of parallel-channel hybrid cooling with baffled forced-flow immersion (PHC-FI-B).
As shown in Figure 9a,b, the transient histories show that both configurations initially heated rapidly from the common starting temperature. The temperature curves progressively separated during the first 100–200 s, with PHC-FI-B exhibiting a lower maximum temperature as the discharge proceeded. Both curves approached plateaus by approximately 300 s and remained nearly constant over the remainder of the 720 s interval. The evolution of ΔTmax follows a similar pattern: the temperature spread increased during the early transient, but its growth was more strongly limited in PHC-FI-B. The sustained separation after the initial heating stage indicates that the thermal improvement persisted throughout the later part of the discharge. At 720 s, Tmax decreased from 33.84 °C for PHC-FI to 32.56 °C for PHC-FI-B, giving an absolute reduction of 1.28 °C. Relative to the common reference temperature of 25 °C, the maximum temperature rise decreased from 8.84 °C to 7.56 °C, corresponding to a reduction of 14.5%. Meanwhile, ΔTmax decreased from 7.45 °C to 5.88 °C, a reduction of 1.57 °C, or 21.1%. These results demonstrate simultaneous improvement in peak-temperature control and module temperature uniformity at the investigated operating condition.
Figure 9. Thermal performance comparison of PHC-FI and PHC-FI-B during 5C discharge, with total water and oil flow rates of 3 L/min each: (a) transient evolution of the maximum battery temperature, Tmax; (b) transient evolution of the maximum module temperature difference, ΔTmax; and (c) battery temperature contours at the end of discharge (t = 720 s), showing PHC-FI on the left and PHC-FI-B on the right.
The temperature contours reinforce this distinction because both configurations are displayed on the same scale of 25.00–33.84 °C, as demonstrated in Figure 9c. PHC-FI exhibits extensive red and dark-orange regions over several cell surfaces, whereas PHC-FI-B shows a smaller extent of the highest-temperature regions and broader green and yellow areas in the central portion of the array. Localized warmer regions remain, consistent with the residual temperature spread of 5.88 °C. Using ΔTmax = Tmax − Tmin, the corresponding minimum temperatures are 26.39 °C for PHC-FI and 26.68 °C for PHC-FI-B. The narrower temperature range thus combines a lower upper limit with a modest increase in the lower limit, indicating a more compact temperature distribution across the module.
The observed pattern is consistent with more effective delivery of circulating oil to regions that were less strongly cooled in the unbaffled configuration. An unrestricted immersion domain can permit preferential flow through passages of lower hydraulic resistance, leaving some cell surfaces less effectively supplied with cooler fluid. The suitably positioned baffles can redirect these paths and promote fluid renewal around the cells, thereby limiting localized heat accumulation. Related immersion cooling research has also demonstrated that baffle geometry influences temperature uniformity and the balance between heat transfer and pressure loss [40,41,42]. Here, the temperature results indicate improved cooling distribution, while velocity fields are needed to identify the specific flow mechanisms.
The velocity-colored streamlines clarify how baffle integration modifies oil transport in the hybrid cooling system, as shown in Figure 10. In both configurations, water enters the indirect cooling channels from the left and exits on the right, whereas oil enters the immersion chamber through the lower connection on the right and leaves through the upper connection on the left. Therefore, the opposed inlet arrangement is common to PHC-FI and PHC-FI-B. At the same 5C discharge rate and water and oil flow rates of 3 L/min per circuit, the principal visible difference is the internal oil route: PHC-FI provides predominantly upward transport through the array, while PHC-FI-B establishes successive upward, downward, and upward passes.
Figure 10. Velocity-colored oil streamlines and flow directions in the hybrid cooling configurations: (a) PHC-FI and (b) PHC-FI-B. Side and three-dimensional views illustrate the opposed water- and oil-inlet arrangement and the alternating oil-flow passages introduced by the baffles.
In PHC-FI, oil entering the lower part of the chamber spreads along the lower clearance, rises through passages around the cells, and converges toward the upper outlet region. The side view shows the same upward flow direction across the module, while the three-dimensional view reveals streamlines extending along the upper and lower clearances. This arrangement allows the immersion flow to divide among multiple passages before recombining near the outlet. Differences in the local pressure driving each passage can consequently produce unequal coolant delivery. The visible peripheral paths identify possible bypass routes, although their contribution to the total flow cannot be determined from streamline density alone.
The baffle arrangement changes this distribution into a more constrained sequence of passes. From the oil-inlet side, the flow passes through the first section of the array, turns into the central section, then descends before turning again and rising through the final section toward the oil outlet. The alternating directions are evident in the side view, and the three-dimensional streamlines confirm the redirection between neighboring sections. By interrupting continuous transport through the peripheral clearances, the baffles guide the oil through successive regions of the cell array. This mechanism can improve fluid renewal around surfaces that receive weaker cooling in the unbaffled configuration. The resulting benefit depends on the local passage areas and flow distribution, because the oil also warms progressively as it absorbs heat.
The shared velocity scale of 0–0.96 m/s provides a consistent basis for interpreting the two flow fields. The highest displayed velocities occur in the connecting pipes, whereas most streamlines within the expanded immersion chamber occupy the lower part of the scale. Thus, the thermal improvement should be interpreted primarily in relation to the redistribution of oil within the chamber. The altered routing provides a plausible explanation for the previously observed reduction in Tmax from 33.84 °C to 32.56 °C and in ΔTmax from 7.45 °C to 5.88 °C. These changes correspond to a 14.5% reduction in maximum temperature rise above 25 °C and a 21.1% reduction in temperature spread. Related immersion cooling research also demonstrates that baffle geometry influences thermal uniformity and the balance between heat transfer and pressure loss [29,40,41]. Both layouts used opposed inlet directions, so their comparison does not isolate an inlet-orientation effect. Baffle performance was assessed at matched circuit flow rates, with the additional oil-circuit pressure drop included in total hydraulic power.
Baffle integration enhanced the oil-side heat transfer response at a fixed oil flow rate of 3 L/min. As shown in Figure 11a, the average oil HTC increased from 388.60 W/(m2·K) for PHC-FI to 514.31 W/(m2·K) for PHC-FI-B, an improvement of 32.3%. The corresponding mean oil Nu increased from 28.51 to 37.73, also by approximately 32.3%. This proportional change is consistent with the use of the same oil thermal conductivity and characteristic length in both configurations. The increase agrees with the guided upward-downward-upward flow route observed in the streamline visualization, which redirects oil through successive sections of the array and can improve fluid renewal around the cells.
Figure 11. Thermo-hydraulic performance comparison of PHC-FI and PHC-FI-B at a 5C discharge rate, with water and oil flow rates of 3 L/min each: (a) average oil- and water-side HTC and Nu; and (b) CPI at α = 1/3, normalized to the PIC reference configuration (CPI = 1).
The water-side response differed from that of the oil circuit. The average water HTC decreased from 1060.76 to 961.81 W/(m2·K), while the mean water Nu decreased from 6.87 to 6.23, representing reductions of approximately 9.3%. Because the water-channel geometry and imposed flow rate were unchanged, this variation should be interpreted in relation to the thermally coupled wall conditions and the reference temperatures used to calculate HTC. A lower water-side HTC alone does not guarantee a proportional decrease in water heat removal; the latter also depends on the wall-to-fluid temperature difference. Accordingly, oil and water HTC and Nu are considered separately, with heat partition between the circuits requiring their individual energy balances.
The stronger oil-side thermal response was accompanied by greater hydraulic demand. As shown in Table 9, the oil pressure drop increased from 649.56 to 1406.20 Pa (116.5%), and the hydraulic pumping power increased from 0.03248 to 0.07031 W. This rise is consistent with the additional flow turns and restricted passages introduced by the baffles. The water pressure drop remained 68.96 Pa, with a hydraulic pumping power of approximately 0.00345 W in both configurations. Summing the two circuit powers yields a total hydraulic pumping power of 0.03593 W for PHC-FI and 0.07376 W for PHC-FI-B, corresponding to a 105.3% increase. Therefore, the baffles improve thermal performance at an appreciable hydraulic penalty under the investigated flow conditions.
Table 9. Comparison of water- and oil-circuit pressure drops and hydraulic pumping powers of PHC-FI and PHC-FI-B configurations.
The previously defined CPI was used to evaluate this trade-off, retaining PIC as the common study-wide reference and adopting α = 1/3. The index uses the maximum temperature rise above 25 °C, the module temperature spread, and the total hydraulic pumping power. As shown in Figure 11b, PHC-FI and PHC-FI-B yielded CPI values of 1.043 and 1.216, respectively, indicating a 16.6% higher score for the baffled configuration. When normalized directly to PHC-FI, the corresponding values are 1.000 and 1.166. The combined thermal gain factor of 1.482 exceeds the cube-root hydraulic penalty factor of 1.271, supporting the selection of PHC-FI-B under this weighting and operating condition.

3.3. Effect of Oil Flow Rate on the Thermo-Hydraulic Performance of PHC-FI-B

The influence of oil flow rate was investigated for the selected PHC-FI-B configuration to assess whether additional immersion-fluid circulation could further limit battery heating and temperature nonuniformity. Simulations were performed at a 5C discharge rate with Pitherm 150B oil flow rates of 1, 3, and 5 L/min. The total water flow rate was maintained at 3 L/min and distributed equally among the three parallel indirect cooling channels at 1 L/min per channel. The battery and coolants were initially at 25 °C, and both coolant inlet temperatures were maintained at 25 °C. The baffle arrangement and inlet locations were unchanged, allowing the effect of oil throughput to be examined under a common geometry and water flow condition.
As shown in Figure 12a,b, the transient histories exhibit a rapid initial temperature rise across all three oil flow rates, followed by a progressive reduction in the heating rate. The curves remain close during the earliest stage and then separate as the influence of oil circulation becomes more pronounced. Increasing the flow rate lowers the subsequent Tmax trajectory and limits the growth of ΔTmax. The 3 and 5 L/min cases approach nearly constant levels earlier than the 1 L/min case, while their lower temperatures and temperature spreads persist throughout the later part of the 720 s discharge interval. The ordering of the late-time curves is consistent for both indicators, with 5 L/min giving the lowest values and 1 L/min the highest. At 720 s, Tmax decreased from 34.75 °C at 1 L/min to 32.56 °C at 3 L/min and 31.62 °C at 5 L/min. The corresponding ΔTmax values were 7.56 °C, 5.88 °C and 5.14 °C. Relative to the common initial and inlet temperature of 25 °C, the maximum temperature rises were therefore 9.75 °C, 7.56 °C and 6.62 °C, respectively. Increasing the oil flow rate from 1 to 5 L/min reduced the peak temperature by 3.13 °C, equivalent to a 32.1% reduction in maximum temperature rise. Over the same range, the module temperature spread decreased by 2.42 °C, or 32.0%. These simultaneous reductions indicate that increased oil circulation improved both peak-temperature control and spatial temperature uniformity.
Figure 12. Effect of Pitherm 150B oil flow rate on the thermal performance of PHC-FI-B at 5C discharge and a total water flow rate of 3 L/min: (a) maximum battery temperature histories; (b) maximum module temperature difference histories; and (c) battery temperature contours at 720 s for oil flow rates of 1, 3, and 5 L/min, displayed on a common temperature scale.
The final temperature contours provide a spatial interpretation of these trends because all three cases use a common scale of 25.00–34.75 °C, as demonstrated in Figure 12c. At 1 L/min, extensive red and dark-orange regions occur over several cell surfaces, indicating pronounced localized heating. At 3 L/min, the highest-temperature regions occupy a smaller area, with more green and yellow regions visible across the array. At 5 L/min, the field shifts further toward green and yellow, with cooler cyan regions around the lower portions of several cells. Local temperature differences remain visible within and between cells, consistent with the residual ΔTmax of 5.14 °C. Thus, increasing flow reduces the severity and extent of warm regions while spatial gradients persist.
The observed improvement is consistent with the increase in the oil heat capacity rate and the more rapid fluid renewal around the cells. For constant oil properties, increasing volumetric flow increases the mass flow rate and hence the capacity to transport absorbed heat. For a given oil-side heat transfer rate, this increase limits the bulk fluid temperature rise and can help maintain the temperature difference driving heat exchange from the cells. Within the baffled geometry, the additional throughput can also strengthen forced transport through the guided passages and improve access to regions with weaker local cooling at the lower flow rate. The previous studies similarly reported improved heat transfer and temperature uniformity as coolant flow increased in a baffled immersion module [29,40,41]. The 5 L/min case produced the lowest predicted temperatures among the tested flow rates. However, the thermal benefit diminished as throughput increased, motivating an assessment against the additional hydraulic demand discussed below.
Figure 13 compares the oil velocity streamlines of PHC-FI-B at 1, 3, and 5 L/min. All three cases exhibit a similar baffle-guided flow pattern through the cell array. Increasing the flow rate raises local velocities, particularly within the inlet and outlet connections, while the overall flow routing remains broadly unchanged. The increased circulation promotes coolant renewal and increases the oil heat-capacity rate, limiting coolant warming for a given absorbed heat load. These effects are consistent with the lower maximum battery temperature and temperature difference observed at higher flow rates. However, the thermal benefits must be evaluated alongside the associated pressure drop and total pumping power of the water and oil circuits.
Figure 13. Oil velocity streamlines in PHC-FI-B at oil flow rates of (a) 1 L/min, (b) 3 L/min, and (c) 5 L/min under 5C discharge, with the total water flow rate maintained at 3 L/min.
As shown in Figure 14a, increasing the oil flow rate from 1 to 3 and 5 L/min raised the oil-side HTC from 297.97 to 514.31 and 614.64 W/(m2·K), respectively, while Nu increased from 21.86 to 37.73 and 45.09. The HTC improved by 72.6% between 1 and 3 L/min but by 19.5% between 3 and 5 L/min, showing diminishing increases in convective heat transfer. Because oil conductivity and the reference length are constant, Nu varies directly with HTC. These trends are consistent with stronger advective heat transport through the baffled passages and the lower battery temperatures at higher flow rates. The water circuit maintained a flow rate of 3 L/min, a pressure drop of 68.96 Pa, and a hydraulic power of 0.00345 W, as indicated in Table 10. The reported water-side HTC and Nu were 961.81 W/(m2·K) and 6.23 at all three oil flow rates. The oil-circuit pressure drop increased from 346.28 Pa at 1 L/min to 1406.20 Pa at 3 L/min and 2826.00 Pa at 5 L/min. The associated oil hydraulic powers, calculated as the pressure drop multiplied by the volumetric flow rate, were 0.00577, 0.07031, and 0.23550 W, respectively. Consequently, total water-plus-oil hydraulic power increased from 0.00922 to 0.07376 and 0.23895 W. Compared with 1 L/min, the 3 and 5 L/min cases required 8.00 and 25.92 times the total hydraulic power, respectively. Therefore, higher flow produced a much steeper increase in hydraulic demand than HTC. This trade-off is particularly clear for the equal 2 L/min increments. Increasing oil flow from 1 to 3 L/min lowered Tmax by 2.19 °C and ΔTmax by 1.68 °C for an additional hydraulic power of 0.06454 W. Increasing it from 3 to 5 L/min yielded smaller reductions of 0.94 °C and 0.74 °C, respectively, despite requiring an additional 0.16519 W. The 5 L/min case provided the best thermal performance, but its marginal cooling benefit was substantially lower.
Figure 14. Effect of oil flow rate on the thermo-hydraulic performance of PHC-FI-B under 5C discharge, with a total water flow rate of 3 L/min: (a) oil- and water-side HTC and Nu; and (b) CPI at α = 1/3, normalized to the PIC reference (CPI = 1).
Table 10. Comparison of water- and oil-circuit pressure drops and hydraulic pumping powers in PHC-FI-B configuration at different oil flow rates.
As shown in Figure 14b, the CPI was evaluated with α = 1/3, maximum temperature rise above 25 °C, and total hydraulic power, retaining PIC as the common reference. This yielded CPI values of 1.467, 1.216 and 1.074 at 1, 3 and 5 L/min, respectively. Therefore, the index decreased by 17.1% from 1 to 3 L/min and by a further 11.7% from 3 to 5 L/min. Although all three cases exceeded the PIC reference of unity, the progressively larger power penalty outweighed the additional thermal gain within this index. Accordingly, 1 L/min offers the highest CPI among the tested flow rates under the stated weighting. Higher flow rates remain relevant when a lower Tmax or ΔTmax is required, and 3 L/min provides an intermediate thermal operating point.
The dependence of the comprehensive performance index (CPI) on its hydraulic-penalty exponent was evaluated using α = 0, 1/3, 1/2, 2/3, and 1. The exponent α is a decision weight rather than a calibrated physical constant. The baseline value α = 1/3 is retained as a prescribed sublinear benchmark: doubling total hydraulic power multiplies the penalty by approximately 1.26. Values α = 0 and 1 represent no hydraulic penalty and a linear penalty, respectively, while 1/2 and 2/3 sample intermediate priorities. These values explore different preferences rather than identify a uniquely correct exponent. All seven investigated operating cases were assessed using the same PIC reference, with the simulated temperatures, flow rates, and pressure drops held unchanged. The influence of the hydraulic-penalty exponent on CPI rankings is examined in Table 11.
Table 11. Sensitivity of CPI to the hydraulic-penalty exponent for the investigated cooling configurations and oil flow rates. Total water flow is 3 L/min in every case. Bold values denote the highest CPI among all seven cases at each exponent.
Table 11 shows that PHC-FI-B at 1 L/min achieves the highest CPI for α = 1/3, 1/2, and 2/3, with values of 1.4670, 1.2452, and 1.0569, respectively. At α = 1, PHC-SI has the highest value, 1.0439. Its CPI is independent of α because its total hydraulic pumping power equals that of the PIC reference. PHC-SI’s CPI of 1.0439, compared with 1.0000 for PIC, derives from small predicted thermal differences at the same hydraulic power. This ranking is a numerical result under the prescribed assumptions; it does not establish a practically meaningful physical advantage over PIC. At α = 0 (the lowest-temperature case), PHC-FI-B at 5 L/min has the highest thermal-benefit factor.
The baffle comparison also depends on the weighting. At 3 L/min oil flow, PHC-FI-B scores higher than PHC-FI at α = 1/3 and 1/2, but their order reverses at α = 2/3 and 1. The calculated crossover is approximately α = 0.5464. The fixed-flow thermal reductions associated with the baffles remain as reported, while their preference within CPI depends on the assigned hydraulic penalty.
Evaluating Equation (24) continuously over 0 ≤ α ≤ 1 gives the highest score to PHC-FI-B at 5 L/min below approximately α = 0.2274, PHC-FI-B at 3 L/min between approximately 0.2274 and 0.2432, PHC-FI-B at 1 L/min between approximately 0.2432 and 0.6793, and PHC-SI above approximately 0.6793. Adjacent cases tie at their crossover values. These thresholds are approximate calculations from rounded simulation inputs, rather than experimentally established limits.
Configuration preferences depend on the adopted hydraulic penalty and required temperature control. The comparisons were performed at prescribed circuit flow rates. Configurations with different hydraulic resistances can require different pumping powers at the same flow rates. The CPI-weighting sensitivity analysis reassesses the existing operating points and does not constitute a comparison at matched total hydraulic power. No standalone immersion control or comparison at matched total hydraulic power was included. Therefore, the results quantify thermal and hydraulic differences among the tested configurations. They do not establish synergistic interaction between the two cooling paths or performance superiority at equal pumping power.

4. Conclusions

A transient thermal-fluid model was used to compare indirect and water-oil hybrid cooling for a 10S6P module of 60 cylindrical 21700 cells over a 720 s nominal 5C discharge. Water flow was fixed at 3 L/min, with initial and coolant inlet temperatures of 25 °C. The findings apply to the specified geometries, operating conditions, and modeling assumptions. Small temperature or CPI differences, particularly between PHC-SI and PIC, should be interpreted as conditional model trends. Their practical significance has not been established through a comprehensive uncertainty assessment.
(a)
The serpentine water layout yielded a maximum battery temperature and a temperature spread 1.88 °C and 1.01 K lower, respectively, than the parallel layout. However, PIC required 91.3% less hydraulic pumping power. At a hydraulic-penalty exponent of α = 1/3, CPI values of 1.000 for PIC and 0.567 for SIC supported selection of the parallel layout for the subsequent hybrid comparisons.
(b)
At an oil flow rate of 3 L/min, PHC-FI yielded a maximum battery temperature of 33.84 °C and a temperature spread of 7.45 K, compared with 38.13 °C and 10.95 K for PHC-SI. Total hydraulic power increased from 0.00345 to 0.03593 W, while CPI remained approximately 1.04 for both at α = 1/3. This configuration-level comparison is subject to the conduction-only treatment of static oil and differences in enclosure geometry.
(c)
At 3 L/min in each circuit, the representative baffled configuration reduced the predicted maximum temperature from 33.84 to 32.56 °C and the temperature spread from 7.45 to 5.88 K relative to PHC-FI. Total hydraulic power increased by 105.3%, while CPI increased by 16.6% to 1.216 at α = 1/3. These results characterize the tested baffle arrangement.
(d)
PHC-FI-B at 5 L/min oil produced the lowest temperatures among the tested cases: a maximum temperature of 31.62 °C and a temperature spread of 5.14 K. Its total hydraulic power was 25.9 times that at 1 L/min. At α = 1/3, the 1 L/min case achieved the highest CPI (1.467); PHC-SI ranked highest at α = 1. Therefore, operating-point preferences depend on the required thermal limits and adopted hydraulic penalty.
The present comparisons do not establish synergistic interaction or superiority at equal pumping power. Future work should prioritize thermal validation of the same cell at 5C, module experiments, temperature-dependent coolant properties, and assessment of buoyancy in static immersion. Standalone immersion controls and comparisons at matched total hydraulic power should accompany further optimization of baffle geometry and water-oil flow allocation.

Author Contributions

Conceptualization, T.D.L. and M.-Y.L.; methodology, T.D.L. and M.-Y.L.; software, T.D.L. and J.-H.P.; validation, T.D.L. and J.-H.P.; formal analysis, T.D.L. and J.-H.P.; investigation, T.D.L., J.-H.P. and M.-Y.L.; resources, T.D.L. and J.-H.P.; data curation, T.D.L. and J.-H.P.; writing—original draft preparation, T.D.L. and J.-H.P.; writing—review and editing, T.D.L. and M.-Y.L.; visualization, T.D.L. and J.-H.P.; supervision, M.-Y.L.; project administration, M.-Y.L.; funding acquisition, M.-Y.L. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by KICOX, funded by the Korean government (MOTIE) (No. VCDM2502), by NRF, funded by the Korean government (MSIT) (No. RS-2026-25605436), and by the Glocal University Initiative of Dong-A University (2025-STR-S1-00). This research was also supported by the ANCHOR program through the BUSAN ANCHOR CENTER, funded by MOE and Busan Metropolitan City, Republic of Korea (2026-ANCHOR-02-003).

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The original contributions presented in the study are included in the article, further inquiries can be directed to the corresponding author.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Lyu, Y.; Chen, L.; Xiang, Z.; Ouyang, L.; Yang, J.; Zhou, T.; Ying, D.; Feng, J.; Chen, B.; Wu, C. Investigation of side-plate cooling on the thermal behavior and safety of 280 Ah battery modules under high-power operation. Results Eng. 2026, 32, 113488. [Google Scholar] [CrossRef] [Scilit]
  2. Wang, X.; Zhao, C.; Zhang, Y.; Ren, G.; Li, J.; Luo, Y.; Jiang, C.; Xue, W.; Wu, X.; Shen, B.; et al. An efficient radiative cooling composite film for Lithium-ion battery thermal management systems. Appl. Therm. Eng. 2026, 308, 133568. [Google Scholar] [CrossRef] [Scilit]
  3. Yang, J.; Zhao, Y.; Diao, Y.; Ren, R. Experimental and numerical investigation of an inclined U-shaped micro heat pipe array–liquid cooling system for large-capacity energy-storage lithium-ion batteries. Appl. Therm. Eng. 2026, 308, 133372. [Google Scholar] [CrossRef] [Scilit]
  4. Ma, K.; Wang, J.; Mao, Q.; Wang, Q. Research on battery thermal management and energy consumption strategies based on hybrid cooling plate. Int. Commun. Heat Mass Transf. 2026, 180, 112670. [Google Scholar] [CrossRef] [Scilit]
  5. Wu, Z.; Long, J.; Luo, D.; Yang, S.; Yang, R.; Li, Z.; Chen, H. Exploiting activation-timing effects in thermoelectric cooling for energy-efficient operation of a hybrid battery thermal management system. Energy 2026, 366, 142706. [Google Scholar] [CrossRef] [Scilit]
  6. Beugre, O.M.; Jesus, T.; Pedro, F.; Brett, M.; Tadeu, A.; Škerget, L.; Lopes, V.; Pinto, J.; Fidalgo, M.; Godinho, R.; et al. Numerical and experimental evaluation of cooling strategies for prismatic li-ion battery modules designed for containerised energy storage. J. Energy Storage 2026, 182, 124998. [Google Scholar] [CrossRef] [Scilit]
  7. Yang, Y.; Xu, X.; Zeng, Z.; Wu, C.; Wang, W.; Wang, Y. Study of a composite cooling structure for automotive power battery modules based on the embedded liquid cooling plate and phase change material. J. Energy Storage 2026, 180, 124129. [Google Scholar] [CrossRef] [Scilit]
  8. Lu, J.; Gao, G.; Lei, M. Thermo-hydraulic performance and flow mechanisms of a jet-impingement-enhanced immersion cooling system for prismatic battery modules. Appl. Therm. Eng. 2026, 308, 133753. [Google Scholar] [CrossRef] [Scilit]
  9. Yuan, M.; Chen, C.; Wang, K.; Wu, S.; Wu, Z.; Zhu, X.; Zhang, Z.; Zhang, Y.; Zeng, C.; Cui, J.; et al. From single-mode cooling to intelligent integrated systems: A systematic review and performance evaluation of Lithium-ion battery thermal management technologies. Appl. Therm. Eng. 2026, 307, 133287. [Google Scholar] [CrossRef] [Scilit]
  10. Luo, C.; Zhao, Y.; Wang, C.; Wang, S.; An, D.; Xi, H. Experimental study and performance evaluation of direct refrigerant cooling/heating thermal management systems for full-scale commercial battery packs. J. Energy Storage 2026, 182, 124816. [Google Scholar] [CrossRef] [Scilit]
  11. Tang, Y.; Li, J.; Meng, X.; Zhou, Z.; Chen, K.; Chen, J.; Guo, W.; Miao, Z.; Zhang, S. A novel flow-guided cold plate with enhanced thermal performance for battery direct refrigerant cooling. Appl. Therm. Eng. 2026, 307, 133322. [Google Scholar] [CrossRef] [Scilit]
  12. Hmidi, N.; Alami Merrouni, A.; Panchal, S.; Fraser, R.; Fowler, M.; Amrani, A.; Chaabelasri, E. Thermo-hydraulic optimization of an energy-efficient LiFePO4 battery cooling system using a bio-inspired cold plate and ternary hybrid nanofluid. Next Energy 2026, 13, 101089. [Google Scholar] [CrossRef] [Scilit]
  13. Hussam, W.K.; Mahamud, R.; Sadman, T.; Alsahlani, A.A.; Saleem, K.B.; Sheard, G.J. Thermal performance of minichannel cold plates with nanofluids for lithium-ion battery cooling in high-temperature climates. J. Energy Storage 2026, 182, 124724. [Google Scholar] [CrossRef] [Scilit]
  14. Park, J.H.; Le, T.D.; Lee, M.Y. Multi-Objective Optimization on Enhanced Heat Transfer and Pumping Power of Cooling Plate-Based Indirect Cooling System for 6S2P Lithium-Ion Battery Module. Energies 2025, 19, 2218. [Google Scholar] [CrossRef] [Scilit]
  15. Ali, A.O.; Abdelrehim, O.; Saafan, M.M.; Elmarghany, M.R.; Hamed, A.M. Numerical investigation of liquid-Cooled battery thermal management system configurations for a lithium-ion battery pack with experimental validation. Sci. Rep. 2026, 16, 23094. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Chen, L.; Qin, Y.; Pan, C.; Cheng, H.; Gao, R.; Li, Y. Externally aerated single-phase immersion cooling for enhanced battery thermal performance: An experimental study. J. Energy Storage 2026, 182, 124522. [Google Scholar] [CrossRef] [Scilit]
  17. An, J.W.; Tae, Y.; Park, S.J.; Jang, S.P.; Lee, G.; Lee, S.U. Effects of working fluids’ properties and battery spacing on battery temperature in single-phase static immersion cooling system. Case Stud. Therm. Eng. 2026, 83, 108157. [Google Scholar] [CrossRef] [Scilit]
  18. Suhendra, B.; Alif Indratma, N.; Kusrini, E.; Putra, N.; Hasanuzzaman, M. Thermal performance and temperature uniformity of battery modules using static single phase immersion cooling with multiple dielectric fluids. Appl. Therm. Eng. 2026, 296, 130774. [Google Scholar] [CrossRef] [Scilit]
  19. Dubey, P.; Pulugundla, G.; Srouji, A.K. Direct Comparison of Immersion and Cold-Plate Based Cooling for Automotive Li-Ion Battery Modules. Energies 2020, 14, 1259. [Google Scholar] [CrossRef] [Scilit]
  20. Jithin, K.; Rajesh, P. Numerical analysis of single-phase liquid immersion cooling for lithium-ion battery thermal management using different dielectric fluids. Int. J. Heat Mass Transf. 2022, 188, 122608. [Google Scholar] [CrossRef] [Scilit]
  21. M., C.; K.V., J.; T., S.; P.K., R. Comprehensive experimental study of battery thermal management using single-phase liquid immersion cooling. J. Energy Storage 2025, 111, 115445. [Google Scholar] [CrossRef] [Scilit]
  22. Tai, L.D.; Garud, K.S.; Lee, M.Y. Experimental Study on Thermal Management of 5S7P Battery Module with Immersion Cooling Under High Charging/Discharging C-Rates. Batteries 2025, 11, 59. [Google Scholar] [CrossRef] [Scilit]
  23. Wang, H.; Xu, Y.; Ji, Z.; Lin, C. Experimental investigation of immersion cooling using insulating oil and forced convection heat transfer in high-energy-density battery modules. J. Therm. Anal. Calorim. 2026, 151, 887–902. [Google Scholar] [CrossRef] [Scilit]
  24. Lu, Y.; Yang, J.; Wu, X.; Ye, G.; Han, X. Investigation on influencing factors and optimization design of thermal performance for automotive-grade liquid immersion cooling of battery modules. J. Therm. Anal. Calorim. 2026, 151, 10677–10700. [Google Scholar] [CrossRef] [Scilit]
  25. Sadeh, M.; Tousi, M.; Sarchami, A.; Sanaie, R.; Kiani, M.; Ashjaee, M.; Houshfar, E. A novel hybrid liquid-cooled battery thermal management system for electric vehicles in highway fuel-economy condition. J. Energy Storage 2024, 86, 111195. [Google Scholar] [CrossRef] [Scilit]
  26. Zou, Z.; Xie, J.; Luo, Y.; Zhang, G.; Yang, X. Numerical study on a novel thermal management system coupling immersion cooling with cooling tubes for power battery modules. J. Energy Storage 2024, 83, 110634. [Google Scholar] [CrossRef] [Scilit]
  27. Dai, C.; Wang, C.; Li, D.; Xi, H. Immersion coupled S-type cooling tube battery thermal management for electric vehicle integration under harsh conditions. Sci. China Technol. Sci. 2026, 69, 1320105. [Google Scholar] [CrossRef] [Scilit]
  28. Gao, Q.; Tian, J.; Bao, C.; Zhong, Y.; Zhang, C.; Chen, Y. Thermal-flow-electric coupling performance analysis of a liquid-immersed battery thermal management system. Sci. China Technol. Sci. 2025, 68, 1120102. [Google Scholar] [CrossRef] [Scilit]
  29. Le, T.D.; Lee, M. Optimization of thermal performance characteristics for 21,700 lithium-ion battery pack utilizing single-phase immersion cooling: A multi-parameter numerical investigation. Int. Commun. Heat Mass Transf. 2026, 172, 110651. [Google Scholar] [CrossRef] [Scilit]
  30. Choi, J.H.; Gwon, J.G.; Lee, M.S.; Choi, H.K.; Park, Y.G. CFD and ANN-based optimization of perforated baffle design in an immersion-cooled BTMS for 21700 lithium-ion batteries. Int. Commun. Heat Mass Transf. 2026, 180, 112685. [Google Scholar] [CrossRef] [Scilit]
  31. Yang, Q.; Yang, T.; Huang, Q.; Hu, W.; Zhang, K.; Shen, J. A synergistic flow regulation strategy for enhanced thermal uniformity in immersion-cooled battery modules. Energy 2026, 362, 142257. [Google Scholar] [CrossRef] [Scilit]
  32. Le, T.D.; Lee, M.Y. Numerical Investigations on Heat Transfer Characteristics of Mono and Hybrid Nanofluids Using Microchannel Cooling for 21700 Batteries in Electric Vehicles. Micromachines 2026, 17, 497. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  33. Kumar, K.; Sarkar, J.; Mondal, S.S. Analysis of ternary hybrid nanofluid in microchannel-cooled cylindrical Li-ion battery pack using multi-scale multi-domain framework. Appl. Energy 2024, 355, 122241. [Google Scholar] [CrossRef] [Scilit]
  34. Kumar, K.; Sarkar, J.; Mondal, S.S. Energy, exergy, and economic evaluations of various cylindrical lithium-ion battery thermal management systems. Int. Commun. Heat Mass Transf. 2025, 165, 109007. [Google Scholar] [CrossRef] [Scilit]
  35. Al-Neama, A.F.; Kapur, N.; Summers, J.; Thompson, H.M. An experimental and numerical investigation of the use of liquid flow in serpentine microchannels for microelectronics cooling. Appl. Therm. Eng. 2017, 116, 709–723. [Google Scholar] [CrossRef] [Scilit]
  36. Karwa, R.; Sharma, C.; Karwa, N. Performance Evaluation Criterion at Equal Pumping Power for Enhanced Performance Heat Transfer Surfaces. J. Sol. Energy 2012, 2013, 370823. [Google Scholar] [CrossRef] [Scilit]
  37. Li, Y.; An, Z.; Meng, J.; Lu, G. Surrogate-assisted multi-objective optimization of a perforated plate for enhanced jet-immersion cooling of high-energy-density batteries. Int. Commun. Heat Mass Transf. 2026, 180, 112584. [Google Scholar] [CrossRef] [Scilit]
  38. Hou, S.; Wang, S.; Chen, K. An improved heat transfer model for hydrofluoroolefin refrigerants in immersion cooling of lithium-ion batteries. Int. J. Heat Mass Transf. 2026, 270, 129244. [Google Scholar] [CrossRef] [Scilit]
  39. Dhamodharan, P.; Barathraj, R.K.; Sathishkumar, A.; Choi, G.S.; Kim, S.C. Experimental investigation of single-phase static immersion cooling using AC-110 dielectric fluid for lithium-ion battery modules. Appl. Therm. Eng. 2026, 300, 131529. [Google Scholar] [CrossRef] [Scilit]
  40. Zhu, H.; Ma, Y.; E, J.; Wei, S. Channel structure design and optimization for immersion cooling system of lithium-ion batteries. J. Energy Storage 2024, 77, 109930. [Google Scholar] [CrossRef] [Scilit]
  41. Gao, Q.; Zhang, Z.; Liu, D. A novel immersion cooling strategy for improving the thermal performance of lithium-ion battery packs. J. Energy Storage 2025, 141, 119121. [Google Scholar] [CrossRef] [Scilit]
  42. Gao, Q.; Lu, Y.; Liu, X.; Chen, Y. A novel pulse liquid immersion cooling strategy for Lithium-ion battery pack. Energy 2024, 310, 133266. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.