Featured Application
Parallel laser readout of multiple DNA Boolean operations can be used for multiplex molecular decision-making and programmable nucleic-acid assays.
Abstract
DNA strand-displacement logic circuits can recognize combinations of nucleic-acid inputs, whereas optical microcavity lasers provide a nonlinear threshold that converts molecular events into binary optical signals. Here, we demonstrate a parallel DNA logic-processing platform in which three independent two-input AND gates are coupled to spatially separated whispering-gallery-mode (WGM) microcavity laser readouts in a three-channel PDMS microfluidic device. Each channel implements a distinct pair of DNA inputs and generates an output strand only when both cognate targets are present; the output is expected to increase the amount of cavity-associated SYTO dye and thereby the optical gain. The three dyes (SYTO 84, SYTO 61, and SYTO 13) were pumped with a wavelength-tunable optical parametric oscillator, one channel after another, and the emission was collected in free space without tapered-fiber coupling. In a single channel, lasing was observed only for the (1,1) input state, with a threshold of approximately 0.3 µJ/mm2. The three channels produced spectrally separated laser peaks, and five representative input combinations were converted into the expected three-bit output vectors with low inter-channel cross-talk. These results establish a route from single molecular logic operations to spatially parallel optical molecular computation.
1. Introduction
DNA-based molecular logic circuits are programmable platforms for biosensing, molecular diagnostics, and information processing. Owing to predictable Watson–Crick base pairing, DNA strands can perform Boolean operations through sequence-specific hybridization and toehold-mediated strand displacement [1,2,3,4,5,6]. Among these operations, the AND gate is particularly useful because it generates a positive output only when two designated DNA inputs are simultaneously present, which may improve molecular selectivity.
Fluorescence-based detection is commonly employed to monitor DNA logic reactions using fluorophore–quencher pairs [3,4,7,8,9,10], DNA-binding dyes [11], or activatable fluorogenic reporters [12]. Although sensitive, fluorescence intensity is affected by background signals, dye concentration, and excitation conditions, and it does not inherently provide a sharp distinction between logical ON and OFF states. Integrating DNA logic circuits with optical microcavity lasers offers a way to address this through threshold-dependent emission.
Whispering-gallery-mode (WGM) microcavities confine light strongly, enabling sensitive detection of molecular binding events [13,14] and, in laser configurations, detection of changes in optical gain and cavity losses [15,16]. Laser emissions increase nonlinearly above a characteristic pump threshold, which can give a distinct optical response to molecular recognition. Microcavity and biological lasers have been applied to DNA sensing, molecular analysis and single-cell studies [16,17,18,19,20,21,22], but the integration of multiple independent DNA logic gates with parallel, wavelength-resolved laser outputs remains relatively unexplored.
In this study, we demonstrate a three-channel microfluidic platform that integrates independent DNA AND gates with silica WGM microcavity lasers. Three DNA-binding dyes, SYTO 84, SYTO 61, and SYTO 13, with representative emission maxima near 582, 645, and 509 nm, respectively, provide spectrally distinguishable responses. In each channel, the presence of two DNA inputs triggers a strand-displacement reaction that generates an output strand, which activates a dye-binding reporter structure. A wavelength-tunable optical parametric oscillator (OPO) enables channel-specific excitation, and free-space collection allows the signals to be analyzed without tapered-fiber coupling.
Our previous work established lasing silica microspheres and optofluidic ring-resonator lasers for DNA detection [17,18] and a parallel Fabry–Pérot microcavity laser array for multiplexed DNA analysis [19]. In those studies, the laser reported the presence or hybridization of target DNA. The present work adds programmable strand-displacement AND logic upstream of the laser, so that the laser state encodes a Boolean combination of two DNA inputs, and combines three such gates with wavelength-coded WGM lasers in a free-space-collected microfluidic array.
2. Materials and Methods
2.1. Architecture of the Three Independent DNA AND Gates
Each channel j (j = 1, 2, 3) used a single gate complex consisting of a 30-nt scaffold strand Sj and an 18-nt output strand Oj that is pre-hybridized to the central 18 nucleotides of Sj (Table S1, Supplementary Materials). The scaffold leaves a single-stranded 6-nt toehold at each end. Input Aj binds the 5′-side toehold of Sj through the 6 nt at its 3′ end and displaces the first 9 bp of Oj by branch migration; input Bj binds the 3′-side toehold of Sj through the 6 nt at its 5′ end and displaces the remaining 9 bp. Each input alone is expected to open only half of the output duplex, whereas both together release Oj, such that Oj = Aj AND Bj. The reporter Rj, which is complementary to Oj, was immobilized on the microspheres. The sequences were designed to maintain orthogonality between the three circuits; the longest complementary stretch between strands of different channels is 5 nt. All strand sequences are listed in Table S1, and Figure S1 and Table S2 show the domain-level design (Supplementary Materials).
2.2. Channel-Specific Molecular-to-Optical Transduction
The output Oj was hybridized with a channel-specific reporter strand immobilized on the microsphere surface to form a DNA duplex accessible to the corresponding SYTO dye near the silica WGM microsphere. Because the gate complex itself may contain duplex regions that bind SYTO dyes before logic activation, an output-selective reporter architecture was used, and the background was evaluated with the OFF input states. No direct dye labeling of Input A or Input B was required. Unbound DNA was removed by rinsing before readout (Section 2.3), so that the laser signal reflects only duplexes anchored to reporters on the microsphere surface. Because the x domain of Aj and the y domain of Bj are each complementary to one half of Rj, the two inputs could in principle bind the reporter side by side without the gate and form a nicked 18-bp duplex; this pathway cannot be excluded by the sequence design alone. Each input alone can form only a 9-bp duplex with Rj. A control with reporter-functionalized microspheres and both inputs but no gate gave no laser emission up to the maximum pump energy density available in our setup (approximately 10 µJ/mm2), indicating that this pathway did not produce a detectable signal under our conditions.
2.3. Microfluidic Array and Free-Space Optical Collection
Device design: Three spatially separated microfluidic channels were fabricated in polydimethylsiloxane (PDMS) on a glass substrate with a distributed Bragg reflector (DBR) (Figure 1a), providing three independent reaction and detection regions for the three AND gates. Each channel had an inlet and an outlet and contained silica WGM microspheres (a nominal diameter of approximately 100 µm [18]) that serve as optical resonators and as substrates for DNA immobilization, functionalized with a channel-specific reporter strand. Physical separation of the channels is essential, since a shared fluid volume would prevent inter-channel logic specificity. The platform was adapted from our previous DNA microsphere laser system [17,18,19].
Figure 1.
Three-channel DNA AND logic and optical readout. (a) Spatially separated WGM microcavities in PDMS microchannels with tunable visible OPO excitation and free-space emission collection. (b) AND-dependent output DNA activates a duplex reporter for SYTO-dye binding.
Sample preparation and dye readout: Microsphere functionalization (Section S3), a buffer, and incubation time followed our previous study [18]. Gate complexes (100 nM) were prepared by hybridizing Sj and Oj at a molar ratio of approximately 1.2:1 (scaffold in slight excess) in a Tris–acetate–EDTA (TAE) buffer containing 12.5 mM MgCl2 (TAE/12.5 mM MgCl2) by heating to 90 °C and then leaving them to cool to room temperature. All subsequent steps, including the gate operation, were carried out at room temperature, as in our previous study [18]. The microspheres were held in recesses formed in the PDMS channel at the interrogation position, so that they stayed in place while the solutions flowed past. No additional blocking step was used, and the reporter surface density was not determined: the reporter was applied so as to cover the surface as densely as possible, and the SYTO dyes were supplied at a high concentration for the same reason. For the AND-gate experiments, the gate complexes (100 nM) and the DNA inputs (100 nM each) were premixed and introduced together into each channel and, after incubation and rinsing (see below), the DNA-binding dye of that channel was added. Channels 1, 2, and 3 contained SYTO 84, SYTO 61, and SYTO 13, respectively, each at 5 µM, as noncovalent nucleic-acid-binding readouts rather than covalent labels. The dyes were selected using manufacturer spectral information (Thermo Fisher Scientific, Waltham, MA, USA: SYTO Green, mp07572; SYTO Orange, mp11360; SYTO Red, mp11340), and the dye concentration was set to balance signal strength, background fluorescence, and possible interference with hybridization.
Reporter immobilization and rinsing: Reporter strands (Table S1), biotinylated at the 5′ end, were immobilized on streptavidin-coated microspheres through the streptavidin–biotin interaction (Section S3, [18]). After the reaction solution was incubated in the channel for 20 min, as in our previous study [18], the microspheres were rinsed with a buffer to remove all unbound DNA. The dye was then introduced, and the microspheres were rinsed again to remove unbound dye before the measurement. Only duplexes hybridized to the surface-immobilized reporters therefore remained, and free double-stranded DNA, including duplexes formed in solution, did not contribute to the laser signal.
Optical excitation and collection: A wavelength-tunable visible optical parametric oscillator (OPO; Continuum, 5 ns pulses, 20 Hz) was tuned to the absorption maximum of each dye, near 567, 628, and 488 nm for SYTO 84, SYTO 61, and SYTO 13, respectively. The pump beam was focused onto the microsphere-containing region of the channel. Emissions were collected in free space by a microscope objective, a spectral filter suppressed the pump background, and the light was analyzed with a spectrometer (spectral resolution 0.025 nm); no tapered fiber was used. Because the microsphere density was low, a single microsphere was located by scanning the chip with a microstage and measuring it; the positioning of microspheres in the recesses is not reproducible. The three channels were excited one after another by tuning the pump wavelength; simultaneous multichannel excitation was not performed.
Laser characterization and logic evaluation: For Channel 1, the pump energy density was varied while emission spectra were recorded, and the spectrally integrated intensity was plotted against it to identify threshold behavior. Laser oscillation was judged from narrow WGM emission features together with a nonlinear increase in the output. For Channel 1, the four input combinations were compared; for the three-channel samples, channel-specific emissions and optical cross-talk were evaluated.
2.4. Experimental Matrix and Lasers
All measurements used an identical buffer (TAE/12.5 mM MgCl2), room temperature, and incubation time, following our previous study [18]. The four input states (Aj,Bj) = (0,0), (1,0), (0,1), and (1,1) were measured on the laser readout for Channel 1 (Figure 2). For Channels 2 and 3, the states were sampled through the parallel-input samples of Figure 3b (Channel 2: (0,0), (1,0), (1,1); Channel 3: (0,0), (0,1), (1,1)); for the remaining single-input states, no laser signal above the detection limit was observed even at sufficiently high pump energy densities, and spectra were not recorded. The complete four-state behavior of all three gates was verified in solution (Section S2, Figure S2). The five samples were chosen to check cross-talk between channels, since the logic of each gate was shown individually; the complete set of input combinations was not measured. Figure 2 shows the mean ± standard deviation of three repeated measurements; the three-channel results in Figure 3 and Figure 4 are single measurements. The lasing threshold of Channel 1 was estimated from segmented linear fits to the low- and high-pump regimes. For channel j, Lj = 1 when a cavity-localized spectral peak appeared that showed a nonlinear, threshold-like increase in the integrated intensity with pump energy density; otherwise, Lj = 0. The three channel states formed the output vector (L1, L2, L3).
Figure 2.
Single-channel AND-gated laser readout (Channel 1, SYTO 84). (a) Emission spectra for the four input states; (b) integrated emission intensity as a function of pump energy density, showing a laser threshold only for the (1,1) state. Error bars: standard deviation of three repeated measurements.
Figure 3.
Parallel three-channel readout. (a) Emission spectra of the three channels for Sample 5 (with all three gates ON), recorded with the pump tuned to the dye of each channel in turn; (b) input conditions and Boolean output vectors for five samples. Line colors indicate the channels. Single measurements were taken.
Figure 4.
Channel selectivity and optical cross-talk evaluation. (a) Emission spectra showing selective optical responses to the corresponding DNA targets in three independent channels. (b) Normalized cross-talk matrix illustrating strong channel-specific responses and low interchannel interference. Line colors indicate the channels. Target j denotes the (1,1) input state of channel j. In (b), rows give the excited channel (only its Target present; the pump was tuned to its dye) and columns give the detection channel (integrated over ±10 nm around the laser peak); each row is normalized to its diagonal element. Off-diagonal elements were below the detection limit (DL), corresponding to an optical isolation of more than 20 dB. Single measurements were taken.
3. Results
3.1. Single-Channel AND-Gated Laser Readout
Figure 2 shows the optical response of an individual DNA AND gate coupled to a WGM microcavity laser, using SYTO 84 as the DNA-binding gain medium (Channel 1). The four input combinations (0,0), (1,0), (0,1), and (1,1) were measured to evaluate the logical selectivity of the gate. When inputs A and B were both present, sequential toehold-mediated strand displacement is expected to release the output strand, which hybridizes with the complementary reporter to form a dye-accessible duplex. This process is expected to increase the local concentration of DNA-bound dye molecules within the optical mode volume and thereby the optical gain available for laser oscillation.
As shown in Figure 2a, the emission spectra exhibited a pronounced laser peak near 611 nm exclusively for the (1,1) input state, whereas the other three combinations remained at the background level. Figure 2b presents the corresponding pump-dependent responses, with error bars representing the standard deviations of three repeated measurements. Only the (1,1) state showed typical lasing behavior with a threshold of approximately 0.3 µJ/mm2, above which the integrated intensity increased nonlinearly, while the remaining states showed only weak signals that rose slowly with pump energy density and stayed about two orders of magnitude below that of the (1,1) state at 10 µJ/mm2. These results show that the molecular AND operation was converted into a binary optical output. Independently of the laser readout, solution-phase kinetics of all three gates showed the same behavior (Figure S2): the (1,1) condition reached 0.68–0.86 of the preformed O + R reference at 60 min, whereas all other conditions, including the gate-free A + B mixture, remained at or below 0.16.
3.2. Parallel Operation of Three Independent AND Gates
To test parallel operation, a distinct two-input logic pair was applied to each channel, and the three cavity outputs were read as one vector (L1, L2, L3). Figure 3b lists the five input combinations and the resulting output vectors. For example, applying (1,1) to Channel 1 and (0,0) to Channels 2 and 3 produced (ON, OFF, OFF), whereas applying no input to any channel produced (OFF, OFF, OFF), and applying (1,1) to all three channels produced (ON, ON, ON). In every sample, only the channels receiving both cognate inputs were ON, so each output vector matched the Boolean AND of the applied inputs.
Figure 3a shows the emission spectra of the three channels for Sample 5 (all three gates ON), recorded with the pump tuned to each channel in turn at energy densities well above the threshold, with laser peaks at approximately 517 nm (Channel 3, SYTO 13), 614 nm (Channel 1, SYTO 84), and 677 nm (Channel 2, SYTO 61). These spectrally separated peaks allowed the three outputs to be distinguished. Because these measurements served to confirm laser emission and to check cross-talk, the thresholds of Channels 2 and 3 were not determined. Peak positions varied by approximately 10 nm or more between individual microspheres (Channel 1: 611 nm in Figure 2a and 614 nm in Figure 3a, and 624 nm in Figure 4a), which we attribute to differences in microsphere diameter, effective refractive index, and other variables. The Q-factors vary from sphere to sphere and could not be determined accurately; estimated from the full width at half maximum (FWHM) of the laser peaks of the better microspheres, they are approximately 100, whereas poorer microspheres show broader linewidths. Figure 3b summarizes the input conditions and output vectors of the five samples.
3.3. Channel Selectivity and Optical Cross-Talk
As shown in Figure 4a, each channel exhibited a pronounced peak in its own detection window upon activation by its designated target, whereas the responses to noncognate targets remained near the background level. Here, Target j denotes the (1,1) input state of channel j. The peaks were approximately 624 nm (Channel 1), 672 nm (Channel 2), and 528 nm (Channel 3); these positions differ from those in Figure 3a because different microspheres were measured.
In the normalized cross-talk matrix (Figure 4b), each row gives the emission in the detection window of each channel (integrated over ±10 nm around its laser peak) when only the Target of the excited channel was present and the pump was tuned to its dye, normalized to the cognate peak of the same row. All off-diagonal elements were below the detection limit of the measurement (a signal more than 20 dB below the laser peak of the target state), corresponding to an optical isolation of more than 20 dB between channels. Because the channels are physically separated and read at different pump wavelengths and detection windows, this matrix quantifies optical cross-talk only; molecular cross-reactivity of the strands in a shared solution was not tested experimentally.
4. Discussion
The three-channel DNA logic platform integrates programmable molecular recognition with threshold-dependent optical readouts. By combining independent DNA AND gates with WGM microcavity lasers, the simultaneous recognition of two DNA inputs was converted into a distinguishable optical output in each channel. Unlike conventional fluorescence-based assays, which generally rely on gradual changes in emission intensity, the microcavity lasers responded nonlinearly above a characteristic excitation threshold, which enabled binary discrimination between logical ON and OFF states.
The platform processed three independent molecular logic operations in parallel: each microfluidic channel implemented a separate AND gate, and SYTO 84, SYTO 61, and SYTO 13 provided spectrally distinct responses, yielding a three-bit optical output. However, the channels were excited one after another by tuning the OPO, so the parallelism is limited to the molecular reactions and the detection.
Free-space collection was chosen to avoid aligning a tapered fiber to each microsphere in every channel, which simplifies the multichannel layout and avoids loading of the cavity by the fiber. The trade-offs are a lower collection efficiency than evanescent coupling, a higher sensitivity to the alignment of the collection objective, and the absence of mode selectivity, so that emissions from several modes or microspheres within the illuminated region may be collected together. These factors are expected to affect the absolute signal and threshold values rather than the binary ON/OFF discrimination, but they were not quantified in this work.
The sensitivity and specificity of the platform were not determined. All experiments used a fixed DNA concentration of 100 nM, and the minimum detectable input concentration and the response to mismatched inputs, including single-base mismatches, were not tested. Toehold-mediated strand displacement is known to discriminate mismatches in solution [1,2], but whether this selectivity carries over to the threshold-gated laser readout remains to be shown.
These results provide a foundation for parallel molecular decision-making and integrated photonic biosensing systems, but several limitations remain. The complete four-state laser truth table was recorded only for Channel 1 (Section 2.4), and the three-channel measurements (Figure 3 and Figure 4) are single measurements. Direct binding of both inputs to the reporter without the gate was tested only in the laser readout (no signal without the gate) and not in solution in the presence of the reporter. The Q-factors and lasing wavelengths of individual microspheres are not uniform: wavelengths shift by approximately 10 nm or more, and the Q-factor (approximately 100 for the better microspheres) and linewidth could not be determined precisely, which may compromise the reliability of wavelength-resolved detection. Improved microsphere uniformity (for example, by size sorting), calibration of each resonator, and quantitative characterization of Q-factors and linewidths will be necessary for scaling to a larger number of channels.
5. Conclusions
We demonstrated a parallel molecular logic platform in which three independent DNA AND gates were mapped onto three spatially separated WGM microcavity laser readouts. Each channel produced a laser ON state only when both cognate DNA inputs were present, and the three channels gave spectrally separated outputs with low cross-talk, forming a three-bit optical output vector. Because the pump wavelength was tuned to each channel in turn, the platform performs parallel molecular processing with wavelength-selective sequential optical readout.
Supplementary Materials
The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/app162311640/s1. Section S1, Figure S1, and Tables S1 and S2: Domain-level design of the gates, strand sequences and domain sequences; Section S2 and Figure S2: Solution-phase fluorescence kinetics of the three AND gates; Section S3: Microsphere functionalization.
Author Contributions
Conceptualization, W.L.; methodology, W.L.; investigation, C.S.J. and W.L.; writing—original draft preparation, C.S.J. and W.L.; writing—review and editing, W.L.; visualization, W.L.; supervision, W.L.; project administration, W.L. All authors have read and agreed to the published version of the manuscript.
Funding
This work was supported by the R&D Program of the Korea Institute of Science and Technology (grant number 26E0231).
Data Availability Statement
The data presented in this study are available on request from the corresponding author.
Acknowledgments
Parts of the schematic illustration in Figure 1 were created with the assistance of ChatGPT GPT-6 and Claude Sonnet 5.5.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| DBR | distributed Bragg reflector |
| DNA | deoxyribonucleic acid |
| FWHM | full width at half maximum |
| OPO | optical parametric oscillator |
| PDMS | polydimethylsiloxane |
| SYTO | trade name of a series of cyanine nucleic-acid stains (Thermo Fisher Scientific) |
| TAE | Tris–acetate–EDTA |
| WGM | whispering-gallery mode |
References
- Zhang, D.Y.; Winfree, E. Control of DNA strand displacement kinetics using toehold exchange. J. Am. Chem. Soc. 2009, 131, 17303–17314. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Srinivas, N.; Ouldridge, T.E.; Šulc, P.; Schaeffer, J.M.; Yurke, B.; Louis, A.A.; Doye, J.P.K.; Winfree, E. On the biophysics and kinetics of toehold-mediated DNA strand displacement. Nucleic Acids Res. 2013, 41, 10641–10658. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Seelig, G.; Soloveichik, D.; Zhang, D.Y.; Winfree, E. Enzyme-free nucleic acid logic circuits. Science 2006, 314, 1585–1588. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Qian, L.; Winfree, E. Scaling up digital circuit computation with DNA strand displacement cascades. Science 2011, 332, 1196–1201. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Qian, L.; Winfree, E.; Bruck, J. Neural network computation with DNA strand displacement cascades. Nature 2011, 475, 368–372. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Qian, L.; Winfree, E. A simple DNA gate motif for synthesizing large-scale circuits. J. R. Soc. Interface 2011, 8, 1281–1297. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Tyagi, S.; Kramer, F.R. Molecular beacons: Probes that fluoresce upon hybridization. Nat. Biotechnol. 1996, 14, 303–308. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhang, D.Y.; Turberfield, A.J.; Yurke, B.; Winfree, E. Engineering entropy-driven reactions and networks catalyzed by DNA. Science 2007, 318, 1121–1125. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhang, D.Y.; Seelig, G. Dynamic DNA nanotechnology using strand-displacement reactions. Nat. Chem. 2011, 3, 103–113. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Stojanovic, M.N.; Mitchell, T.E.; Stefanovic, D. Deoxyribozyme-based logic gates. J. Am. Chem. Soc. 2002, 124, 3555–3561. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Baytekin, H.T.; Akkaya, E.U. A molecular NAND gate based on Watson–Crick base pairing. Org. Lett. 2000, 2, 1725–1727. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Emanuelson, C.; Bardhan, A.; Deiters, A. DNA logic gates for small molecule activation circuits in cells. ACS Synth. Biol. 2024, 13, 538–545. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Vollmer, F.; Arnold, S. Whispering-gallery-mode biosensing: Label-free detection down to single molecules. Nat. Methods 2008, 5, 591–596. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Suter, J.D.; White, I.M.; Zhu, H.; Shi, H.; Caldwell, C.W.; Fan, X. Label-free quantitative DNA detection using the liquid core optical ring resonator. Biosens. Bioelectron. 2008, 23, 1003–1009. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Fan, X.; Yun, S.-H. The potential of optofluidic biolasers. Nat. Methods 2014, 11, 141–147. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sun, Y.; Fan, X. Distinguishing DNA by analog-to-digital-like conversion by using optofluidic lasers. Angew. Chem. Int. Ed. 2012, 51, 1236–1239. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Jun, C.S.; Lee, W. High-throughput DNA analysis platform based on an optofluidic ring resonator laser. Appl. Sci. 2022, 12, 12143. [Google Scholar] [CrossRef] [Scilit]
- Jun, C.S.; Lee, W. Development of lasing silica microsphere for high-speed DNA molecular detection. Sensors 2024, 24, 6088. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Jun, C.S.; Lee, W. Parallel DNA molecular analysis platform based on a plano-concave Fabry–Pérot microcavity laser array. Photonics 2025, 12, 1144. [Google Scholar] [CrossRef] [Scilit]
- Toropov, N.; Cabello, G.; Serrano, M.P.; Gutha, R.R.; Rafti, M.; Vollmer, F. Review of biosensing with whispering-gallery mode lasers. Light Sci. Appl. 2021, 10, 42. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Chen, Y.-C.; Fan, X. Biological lasers for biomedical applications. Adv. Opt. Mater. 2019, 7, 1900377. [Google Scholar] [CrossRef] [Scilit]
- Gather, M.C.; Yun, S.H. Single-cell biological lasers. Nat. Photonics 2011, 5, 406–410. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.