Skip to Content
Applied SciencesApplied Sciences
  • Article
  • Open Access

22 July 2025

12 Pages

Automated Traumatic Bleeding Detection in Whole-Body CT Using 3D Object Detection Model

,
,
,
and
1
Department of Medical Engineering, Graduate School of Science and Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
2
Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, 1-8-1, Inohana, Chuo-ku, Chiba 260-8677, Japan
3
Center for Frontier Medical Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
*
Author to whom correspondence should be addressed.
This article belongs to the Special Issue Research Progress in Medical Image Analysis

Abstract

Traumatic injury remains a major cause of death worldwide, with bleeding being one of its most critical and life-threatening consequences. Whole-body computed tomography (WBCT) has become a standard diagnostic method in trauma settings; however, timely interpretation remains challenging for acute care physicians. In this study, we propose a new automated method for detecting traumatic bleeding in CT images using a three-dimensional object detection model enhanced with an atrous spatial pyramid pooling (ASPP) module. Furthermore, we incorporate a false positive (FP) reduction approach based on multi-organ segmentation, as developed in our previous study. The proposed method was evaluated on a multi-institutional dataset of delayed-phase contrast-enhanced CT images using a six-fold cross-validation approach. It achieved a maximum sensitivity of 90.0% with 587.3 FPs per case and a sensitivity of 70.0% with 46.9 FPs per case, outperforming previous segmentation-based methods. In addition, the average processing time was reduced to 4.2 ± 1.1 min. These results suggest that the proposed method enables rapid and accurate bleeding detection, demonstrating its potential for clinical application in emergency trauma care.

1. Introduction

Traumatic injury is a leading cause of mortality worldwide, particularly among young adults [1,2]. Common causes include traffic accidents, falls, and acts of violence, which often require immediate medical intervention, such as resuscitation or surgical procedures. Traumatic bleeding, caused by vascular rupture, can lead to blood extravasation into tissues, organs, or body cavities and represents a critical, potentially fatal complication. Uncontrolled bleeding is the leading cause of preventable trauma-related deaths, accounting for approximately 40% of such fatalities [3].
Whole-body computed tomography (WBCT) has become the standard diagnostic modality in trauma settings owing to its ability to rapidly provide a comprehensive overview with high sensitivity and specificity [1,4,5]. However, the large number of image slices, often hundreds to thousands, poses a significant challenge for acute care physicians, who must interpret them under time constraints. In this context, computer-aided detection (CAD) software can provide valuable support.
CAD software has seen active advancements in the detection of various abnormalities [6,7], and several applications have been developed for trauma CT images, including those for detecting fractures [8,9], critical findings in head CT images [10], bleeding in head CT images [11,12,13,14,15], bleeding in WBCT images [16,17,18], and abdominal injuries, including extravasation [19]. Although bleeding detection has been extensively studied in head CT images, studies targeting other body regions remain limited. For example, Shen et al. [19] addressed various types of abdominal injuries, including extravasation, using a slice-by-slice classification approach based on two-dimensional (2D) segmentation and 2.5D classification. While Shen et al. employed a slice-wise classification approach, our previous studies explored a three-dimensional (3D) segmentation model that directly identifies bleeding regions in WBCT images [16,17,18]. Our latest approach [18] integrates 3D U-Net#-based bleeding detection with false positive (FP) reduction based on multi-organ segmentation, yielding 76.0 FPs per case at a sensitivity of 70.0%, with a processing time of approximately 6 min. Although this method shows promise, reducing false positives and accelerating the process would likely make it more practical for clinical use.
Given the limitations of our previous segmentation-based method, we adopted a 3D object detection framework. This approach was inspired by the promising results reported by Assis et al. [20], who demonstrated that 3D object detection models can outperform segmentation-based methods in terms of both detection performance and processing speed. While Assis et al. [20] applied 3D object detection to detect cerebral aneurysms in head magnetic resonance angiography images, our study is the first to apply this approach to traumatic bleeding detection in WBCT. Unlike cerebral aneurysms, bleeding regions exhibit wide variability in shape and size. Therefore, instead of assuming spherical lesion shapes as in previous aneurysm detection studies, we adopted a flexible cuboid representation using 3D bounding boxes to better accommodate irregular bleeding patterns. Building on this insight, we propose a novel automated method for detecting traumatic bleeding in WBCT images, based on a 3D object detection model inspired by [20] and enhanced with an atrous spatial pyramid pooling (ASPP) module [21]. The proposed CAD software was evaluated using trauma WBCT images collected from multiple institutions.

2. Materials and Methods

2.1. Dataset

This study was approved by our institutional ethical review board. We used the same three types of datasets as in our previous study [18]. The first dataset comprised 75 delayed-phase contrast-enhanced CT scans of trauma patients collected from four institutions (Datasets A–D in Table S1). At least one venous extravasation was present in each case, resulting in a total of 305 bleedings. Each bleeding region was manually annotated voxel-wise by a board-certified acute care physician (A.B., with eight years of emergency medicine experience) using a web-based image database system (CIRCUS DB) [22]. The second dataset comprised 15 delayed-phase contrast-enhanced CT scans from a single institution (Dataset E in Table S1), which were used to train the slice selection model. The third dataset included 196 CT scans from the TotalSegmentator dataset ver. 2.1 [23] and was used to train the multi-organ segmentation model.

2.2. Detection Method Used in This Study

Figure 1 presents an overview of the proposed bleeding detection pipeline, which consists of four main stages: preprocessing, bleeding detection, multi-organ segmentation, and FP reduction. The algorithm is specifically designed to detect bleeding in CT slices from the chest to the foot.
Figure 1. Overview of the proposed bleeding detection pipeline. CT images are preprocessed and passed through a 3D object detection model with an atrous spatial pyramid pooling (ASPP) module. False positives (FPs) are reduced using organ-overlap filtering, small box removal, and non-maximum suppression. Multi-organ segmentation supports this process and the 2D U-Net model was trained in our previous study [18]. The method achieves fewer false positives and faster detection.

2.2.1. Preprocessing

The preprocessing pipeline included body region extraction, slice selection, and isotropic resampling. A detailed description of each processing step is provided in [18]. Body region extraction was performed using a combination of thresholding and morphological operations. To improve the processing efficiency, we parallelized the processing of each axial slice and executed the final connected component analysis on a graphics processing unit (GPU). The slice selection employed a 2D ResNet-18 model [24], which classified each slice as belonging to the head and neck or body trunk. Subsequently, trilinear interpolation was applied to the cropped CT scans and corresponding body masks to produce isotropic volumes, ensuring that the resulting voxel size matched the in-plane pixel size of the original image.

2.2.2. Bleeding Detection

We used three types of normalized images, following the approach described in our previous studies [16,18]. The normalization ranges were set to [0, 160], [160, 320], and [320, 450] Hounsfield Units (HU), respectively. After normalization, all voxel values were scaled to the range of [0, 1].
Figure 2 shows the architecture of the 3D object detection model used in this study, which comprises two main components: the backbone and the detection head. This model was inspired by DeepAneDet [20], originally proposed for the detection of cerebral aneurysms. In our setting, the model takes a 3 × 96 × 96 × 96 cubic volume of interest (VOI) and partitions it into a 12 × 12 × 12 grid of spatial cells. Each cell is responsible for predicting the presence and location of bleeding centered within its defined region. Unlike the original DeepAneDet model, which is optimized for detecting near-spherical lesions such as aneurysms, our method replaces the spherical target representation with a standard bounding box format (x, y, z, width, height, depth), better accommodating bleeding regions with varying shapes.
Figure 2. Three-dimensional object detection model used in bleeding detection.
The input VOI was encoded into feature maps through the backbone. These feature maps were then processed by the detection head, which divided them into a grid of 1728 cells using two parallel convolution layers. The first convolution yielded a confidence score (c) for each cell, indicating the probability that a bleeding center was located within that cell. For positive cells (i.e., those containing a bleeding center), the second convolution estimated the center coordinates (x, y, z) and dimensions of the bounding box (width, height, depth). Activation functions were applied after the final 3D convolutions: a sigmoid function was used to predict the confidence scores and center coordinates, while an exponential function was applied to predict the bounding box dimensions.
To further improve the detection performance, we incorporated an ASPP module [21] at the beginning of the detection head. The structure of the ASPP module used in our model is illustrated in Figure 3. This module enhances the model’s ability to capture multiscale contextual information by applying atrous (dilated) convolutions with different dilation rates [21], making it effective for detecting bleeding regions of varying sizes and shapes. Based on preliminary experiments, we selected dilation rates of {3, 6, 9}.
Figure 3. Structure of the ASPP module.
During the training phase, pairs of normalized images and their corresponding bleeding regions were used. For each bleeding region, a 3 × 96 × 96 × 96 cubic VOI was extracted centered at the center of gravity of the bleeding region. Data augmentation involved the generation of four variants from each original VOI using random spatial transformations. These included shifts of up to 16 voxels along each spatial dimension and fixed-angle rotations (0°, 90°, 180°, or 270°) in all anatomical planes (axial, coronal, and sagittal) to simulate positional variability. These augmentations were dynamically applied across epochs. The model was trained for 100 epochs with a batch size of four using stochastic gradient descent (SGD) with a momentum of 0.9. A stepwise learning rate scheduler was applied, with rates set to 0.01 for epochs 1–50, 0.001 for epochs 51–75, and 0.0001 for epochs 76–100. We adopted a weighted loss function inspired by You Only Look Once (YOLO) [25], combining the detection confidence and bounding box regression terms. Unlike a previous study that used mean squared error (MSE) for spherical targets [20], we regressed all six parameters of the 3D cuboids.
During detection, 3 × 96 × 96 × 96 cubic VOIs were extracted from lattice points within the bounding box of the body region, with an interval of 48 voxels in each direction. Each VOI was then fed into the trained 3D object detection model to predict candidate bleeding regions as bounding boxes. The predicted bounding boxes were subsequently decoded and mapped back to the original CT coordinate space.

2.2.3. FP Reduction

A notable number of FPs emerged from the bleeding detection method, particularly within the bone, kidney, and vascular regions. This trend is consistent with previously reported findings [18]. To address this issue, we incorporated an FP reduction strategy based on multi-organ segmentation, as developed in [18].
To prepare the CT data for organ segmentation, we first resampled the volumes to an isotropic resolution of 1.5 mm using trilinear interpolation. Each axial slice was padded with −1000 Hounsfield Units (HU) to fit a standardized matrix size of 512 × 512 pixels. Voxel values were then linearly scaled from the native [−1000, 1000] HU window to a normalized range of [−1, 1]. A 2D U-Net [26], trained on the same anatomical structures as in our previous study [18], was employed to extract the bone, kidney, and vessel regions. Subsequently, post-processing was performed using multiple processes, such as region growing, morphological operations, and connected component analysis. The segmented result was resampled to align with the isotropic resolution employed in the bleeding detection.
For FP reduction, we employed organ-overlap filtering, as shown in Figure 1. In this process, any predicted bounding box overlapping more than 30% with segmented organ regions was removed. In addition, predicted boxes with any dimension smaller than five voxels were discarded. Finally, non-maximum suppression (NMS) [27] with an Intersection over Union (IoU) threshold of 10% was applied to eliminate redundant bleeding candidates.

2.3. Evaluation

We evaluated the performance of the proposed method using a six-fold cross-validation strategy (Figure 4). The dataset was randomly partitioned into six subsets, each consisting of approximately 12 to 13 cases and 50 to 52 bleeding regions. In each fold, four subsets were allocated for training, one for validation, and the remaining one for testing. The proposed CAD software was implemented using Python 3.8.12, PyTorch 2.1, and CuPy 13.4.0. All computations were performed on a workstation equipped with an Intel Core i9-9900K 3.6 GHz eight-core processor, 64 GB RAM (Intel, Santa Clara, CA, USA), and an NVIDIA RTX 4000 SFF Ada Generation GPU (Nvidia, Santa Clara, CA, USA). The operating system was Ubuntu 22.04.3 LTS running on Windows 11 via the Windows Subsystem for Linux 2 (WSL2), with NVIDIA Driver version 537.70, CUDA 12.1, and cuDNN 8.9.5.
Figure 4. Design of six-fold cross-validation.
The detection performance was evaluated using free-response receiver operating characteristic (FROC) analysis [28]. A bleeding candidate was classified as a true positive (TP) if it satisfied at least one of the following conditions: (a) the center of the predicted bounding box is located within the corresponding bleeding region, or (b) the Euclidean distance between the predicted box center and bleeding center is less than the bleeding radius. Candidates who did not meet these criteria were classified as FP. We applied the bootstrap method [29] to compute 95% confidence intervals (CIs) by drawing 1000 case-level replicates, each preserving the original number of cases. FROC curves were recalculated for each method for each replicate.

3. Results

Figure 5 compares the FROC curves of our previous method [19] with those of the proposed methods. The 3D object detection model without the ASPP module achieved a maximum sensitivity of 85.8% at 567.5 FPs per case. Incorporating the ASPP module further improved the maximum sensitivity to 90.0%, with 587.3 FPs per case. In contrast, the previous method achieved a maximum sensitivity of 83.7% at 598.4 FPs per case. Table 1 summarizes the number of FPs per case at various sensitivity levels. For the proposed method without the ASPP module, the numbers of FPs per case at sensitivities of 60.0% and 70.0% were 31.7 (95% CI: 31.3–32.0) and 57.8 (95% CI: 57.1–58.5), respectively. With the ASPP module, these values improved to 24.3 (95% CI: 24.0–24.6) and 46.9 (95% CI: 46.4–47.4), respectively. As shown in Figure 5 and Table 1, the proposed method with the ASPP module consistently outperformed our previous method by reducing the number of FPs per case across all sensitivity levels. Moreover, the non-overlapping 95% CIs suggest a potentially meaningful difference between the methods.
Figure 5. Average free-response receiver operating characteristic (FROC) curves with 95% confidence intervals along the sensitivity axis (semi-transparent) based on 1000 bootstrap replicates.
Table 1. Comparison of the number of false positives (FPs) per case between our previous method and the proposed methods. Values in parentheses indicate 95% confidence intervals.
Table 2 compares the processing times of the previous and proposed methods using the ASPP module. The proposed method required 4.0 ± 1.0 min, reducing the processing time by 2.2 min compared to the previous method, which took 6.2 ± 2.0 min.
Table 2. Comparison of inference computation time (min) between the previous method and the proposed methods. Data are mean ± standard deviation.
Figure 6 presents two examples comparing detection results with and without the ASPP module. These examples demonstrate successful bleeding detection, regardless of the presence or absence of the ASPP module. However, when comparing the cases with and without the ASPP module, FPs are more effectively reduced when the ASPP module is incorporated. Figure 7 shows examples of the remaining FPs after FP reduction. Figure 7a shows FPs in streak artifacts caused by an artificial object, while Figure 7b presents FPs present in thin vessels. In Figure 7b, multiple clusters are observed, each consisting of several small bounding boxes.
Figure 6. Examples of detection results: (a) bleeding near pelvic bone fracture and (b) bleeding in the adrenal gland. All images show the axial section. Green boxes indicate areas of bleeding (ground truth, GT), yellow boxes indicate areas of TPs, and red boxes indicate areas of FPs.
Figure 7. Examples of remaining FPs after FP reduction (detection model: with the ASPP module): (a) FPs in streak artifacts due to an artificial object, and (b) FPs in thin vessels. All images show the axial section. Green boxes indicate areas of bleeding (ground truth, GT), yellow boxes indicate areas of TPs, and red boxes indicate areas of FPs. Orange arrows indicate thin vessels.

4. Discussion

We developed an automated method for detecting traumatic bleeding in WBCT images using a 3D object detection model enhanced with an ASPP module. The proposed CAD software achieved a sensitivity of 70.0% with 46.9 FPs per case. Across all sensitivity levels, the proposed method, incorporating the ASPP module, outperformed our previous method [18]. Replacing the segmentation-based 3D U-Net# with a 3D object detection model (without the ASPP module) improved the maximum detection sensitivity but did not reduce the number of FPs per case at sensitivity below 80%. In contrast, incorporating the ASPP module further improved the maximum sensitivity and reduced the number of FPs per case at a sensitivity below 80%. By applying atrous convolutions with varying dilation rates, the module enabled multi-resolution analysis of high-level semantic features, which proved effective for detecting bleeding regions of different sizes and shapes. Positioned at the end of the encoder, the ASPP module leverages high-level semantic features to aggregate contextual information across multiple scales. Consequently, the proposed method maintains or improves sensitivity and significantly reduces the number of FPs per case, particularly at higher sensitivity thresholds, thereby increasing the clinical viability compared to that of our previous method. Furthermore, the non-overlapping 95% CIs for the number of FPs per case suggest that the observed reductions are statistically meaningful.
Despite these improvements, some FPs persist. One contributing factor is artifacts caused by artificial objects or motion, as shown in Figure 7a. Another major cause of FPs is thin vessels (Figure 7b), which appear as tubular structures with high CT values and are difficult to distinguish from bleeding. The variability in contrast enhancement across scans further complicates the accurate extraction of these thin vessels. Although region-growing is employed during post-processing in multi-organ segmentation to extract thin vessels, accurate segmentation remains challenging. A potential approach to address these persistent FPs is to incorporate a classification step using a 3D convolutional neural network that analyzes the VOIs containing the lesion candidate after the FP reduction stage.
A characteristic output pattern observed in the object detection model is the clustering of multiple small bounding boxes, as shown in Figure 7b. This clustering appears not only around the true bleeding regions but also in regions without bleeding, suggesting that such patterns contribute to the remaining FPs. Although small-region removal and NMS were applied as part of the FP reduction process, this fragmentation persisted, indicating that the current post-processing pipeline has limited effectiveness in eliminating such clustered FPs. To further reduce this redundancy, additional strategies, such as confidence-aware merging or spatial clustering, could be explored to combine overlapping predictions more effectively.
As our method shows a relatively high number of FPs per case in high-sensitivity settings, this may raise concerns regarding its clinical use. However, in practical CAD software, it is common to adjust the number of findings presented to physicians by applying confidence-based thresholds to balance sensitivity and the number of FPs. This approach has been widely adopted in various detection tasks [30,31].
The proposed method reduced the processing time to 4.2 ± 1.1 min, shortening it by approximately 2.2 min compared to the previous method [18]. This improvement arises from the replacement of the 3D U-Net# model with a 3D object detection model for bleeding detection. The U-Net# architecture extends the vanilla 3D U-Net by adding dense and full-scale skip connections. In contrast, the 3D object detection model uses a residual network-based backbone and detection head. As the object detection model does not include a decoder structure like that of U-Net, it achieves reduced inference time. Several studies have reported that the median time from CT examination to diagnosis is approximately 20–30 min [32,33,34]. Given that the median time from CT examination to diagnosis has been reported to be approximately 20–30 min [32,33,34], our CAD software is considered clinically feasible if it delivers outputs within 20 min when used as a second reader. In contrast, Murao et al. [1] reported a significantly improved 28-day survival rate after shortening the time from arrival at the emergency room to bleeding control procedures. Therefore, further reduction in processing time is essential.
The bounding boxes used to train the 3D object detection model were generated from manually defined regions using voxel-wise painting. Generally, defining bounding boxes is significantly less time-consuming than voxel-wise painting [35,36]. Despite the coarser annotation granularity of bounding boxes compared to voxel-wise paintings, our object detection-based approach demonstrated superior detection performance compared with segmentation-based approaches. This suggests that additional training data can be annotated using bounding boxes alone. Furthermore, this approach may be suitable for detecting fractures that are often challenging to define using voxel-wise painting. The proposed method could be extended to fracture detection by preparing bounding box annotations for the images. Additionally, because object detection models can simultaneously identify multiple types of regions, we plan to develop CAD software capable of detecting both bleeding and fractures.
This study has several limitations. First, only delayed-phase contrast-enhanced CT images were used. Although including non-contrast CT images may enhance the detection performance, it would require image registration between contrast-enhanced and non-contrast CT scans. Although various registration methods exist, including rigid, non-rigid, and deep-learning-based approaches, determining the most compatible option for our system architecture remains a challenge. Alternatively, generating pseudo non-contrast CT images from contrast-enhanced images using GANs [37] has shown promise. However, both strategies introduce additional computational steps, highlighting the need to balance the overall processing efficiency carefully. Second, our detection method targets bleeding located from the chest to the lower extremities. Because trauma CT scan protocols differ across institutions, the scan range for delayed-phase contrast-enhanced CT is inconsistent. Chidambaram et al. [4] reported that a typical delayed-phase scan range encompasses the chest, abdomen, and pelvis. All cases in the multi-institutional dataset used in this study included these anatomical regions. As various CAD software already exists for detecting bleeding in head CT images, bleeding located in the head was excluded from the scope of this study. Third, our evaluation focused only on the stand-alone performance of the CAD software. An observer performance study is desirable to evaluate the overall performance of physicians assisted by CAD software.

5. Conclusions

We developed an automated method for detecting traumatic bleeding in WBCT images using a 3D object detection model incorporating an ASPP module. The proposed method yielded improved detection performance and shortened processing time compared to our previous method. The main contributions of this study are as follows:
  • The integration of the ASPP module into the 3D object detection model enhanced detection performance by enabling the extraction of multiscale contextual information and long-range dependencies, particularly for bleeding of varying shapes and sizes.
  • The proposed method achieved 70.0% sensitivity with 46.9 FPs/case and reduced processing time to 4.0 min, improving the clinical applicability of the CAD software in emergency trauma care.
  • The proposed framework enables efficient data labeling with bounding boxes and can be expanded to detect other traumatic injuries, such as fractures.
Future work will focus on further reducing FPs and expanding the detection targets to include other types of traumatic injuries.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/app15158123/s1, Table S1: Specifications of the trauma CT dataset.

Author Contributions

Conceptualization, T.-a.N., T.N. and Y.N.; Methodology, R.N., T.N. and Y.N.; Software, R.N. and Y.N.; Validation, R.N. and Y.N.; Formal Analysis, R.N., T.N. and Y.N.; Investigation, R.N., T.N. and Y.N.; Resources, A.B., T.-a.N. and Y.N.; Data Curation, A.B., T.-a.N. and Y.N.; Writing—Original Draft Preparation, R.N.; Writing—Review and Editing, A.B., T.-a.N., T.N. and Y.N.; Visualization, R.N. and Y.N.; Supervision, Y.N.; Project Administration, Y.N.; Funding Acquisition, Y.N. All authors have read and agreed to the published version of the manuscript.

Funding

This work was partially supported by JST SPRING, Grant Number JPMJSP2109.

Institutional Review Board Statement

All procedures involving human participants were performed in accordance with the ethical standards of the institutional and/or national research committee and with the 1975 Helsinki Declaration, as revised in 2008(5). The requirement for formal consent was waived, considering the nature of the study. This study was approved by the Institutional Review Board of Chiba University Graduate School of Medicine (approval number: 2972; approval date: 27 February 2018).

Data Availability Statement

Owing to the ethical restrictions imposed by the Research Ethics Committee, the bleeding detection dataset cannot be made publicly available. The original data from the TotalSegmentator dataset [23] are available at https://zenodo.org/records/10047292, accessed on 17 July 2025.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Murao, S.; Yamakawa, K.; Kabata, D.; Kinoshita, T.; Umemura, Y.; Shintani, A.; Fujimi, S. Effect of earlier door-to-CT and door-to-bleeding control in severe blunt trauma: A retrospective cohort study. J. Clin. Med. 2021, 10, 1522. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. World Health Organization. Injuries and Violence. Available online: https://www.who.int/news-room/fact-sheets/detail/injuries-and-violence (accessed on 10 June 2025).
  3. Perel, P.; Prieto-Merino, D.; Shakur, H.; Clayton, T.; Lecky, F.; Bouamra, O.; Russell, R.; Faulkner, M.; Steyerberg, E.W.; Roberts, I. Predicting early death in patients with traumatic bleeding: Development and validation of prognostic model. BMJ 2012, 345, e5166. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Chidambaram, S.; Goh, E.L.; Khan, M.A. A meta-analysis of the efficacy of whole-body computed tomography imaging in the management of trauma and injury. Injury 2017, 48, 1784–1793. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  5. Huber-Wagner, S.; Lefering, R.; Kanz, K.-G.; Biberthaler, P.; Stengel, D. The importance of immediate total-body CT scanning. Lancet 2017, 389, 502–503. [Google Scholar] [CrossRef] [Scilit]
  6. van Ginneken, B.; Schaefer-Prokop, C.M.; Prokop, M. Computer-aided diagnosis: How to move from the laboratory to the clinic. Radiology 2011, 261, 719–732. [Google Scholar] [CrossRef] [Scilit]
  7. Fujita, H. AI-Based Computer-aided diagnosis (AI-CAD): The latest review to read first. Radiol. Phys. Technol. 2020, 13, 6–19. [Google Scholar] [CrossRef] [Scilit]
  8. Meng, X.H.; Wu, D.J.; Wang, Z.; Ma, X.L.; Dong, X.M.; Liu, A.E.; Chen, L. A fully automated rib fracture detection system on chest CT images and its impact on radiologist Performance. Skelet. Radiol. 2021, 50, 1821–1828. [Google Scholar] [CrossRef] [Scilit]
  9. Ukai, K.; Rahman, R.; Yagi, N.; Hayashi, K.; Maruo, A.; Muratsu, H.; Kobashi, S. Detecting pelvic fracture on 3D-CT using deep convolutional neural networks with multi-orientated slab images. Sci. Rep. 2021, 11, 11716. [Google Scholar] [CrossRef] [Scilit]
  10. Chilamkurthy, S.; Ghosh, R.; Tanamala, S.; Biviji, M.; Campeau, N.G.; Venugopal, V.K.; Mahajan, V.; Rao, P.; Warier, P. Deep learning algorithms for detection of critical findings in head CT scans: A retrospective study. Lancet 2018, 392, 2388–2396. [Google Scholar] [CrossRef] [Scilit]
  11. Cho, J.; Park, K.-S.; Karki, M.; Lee, E.; Ko, S.; Kim, J.K.; Lee, D.; Choe, J.; Son, J.; Kim, M.; et al. Improving sensitivity on identification and delineation of intracranial hemorrhage lesion using cascaded deep learning models. J. Digit. Imaging 2019, 32, 450–461. [Google Scholar] [CrossRef] [Scilit]
  12. Burduja, M.; Ionescu, R.T.; Verga, N. Accurate and efficient intracranial hemorrhage detection and subtype classification in 3D CT scans with convolutional and long short-term memory neural networks. Sensors 2020, 20, 5611. [Google Scholar] [CrossRef] [Scilit]
  13. Wang, X.; Shen, T.; Yang, S.; Lan, J.; Xu, Y.; Wang, M.; Zhang, J.; Han, X. A deep learning algorithm for automatic detection and classification of acute intracranial hemorrhages in head CT scans. NeuroImage Clin. 2021, 32, 102785. [Google Scholar] [CrossRef] [Scilit]
  14. Alis, D.; Alis, C.; Yergin, M.; Topel, C.; Asmakutlu, O.; Bagcilar, O.; Senli, Y.D.; Ustundag, A.; Salt, V.; Dogan, S.N.; et al. A joint convolutional-recurrent neural network with an attention mechanism for detecting intracranial hemorrhage on noncontrast head CT. Sci. Rep. 2022, 12, 2084. [Google Scholar] [CrossRef] [Scilit]
  15. Sanner, A.P.; Grauhan, N.F.; Brockmann, M.A.; Othman, A.E.; Mukhopadhyay, A. detection of intracranial hemorrhage for trauma patients. In Lecture Notes in Computer Science, Proceedings of the 27th International Conference on Pattern Recognition, Kolkata, India, 1–5 December 2024; Springer: Cham, Switzerland, 2024; pp. 1–14. [Google Scholar]
  16. Yang, L.; Yang, T.; Kimura, H.; Yoshimura, Y.; Arai, K.; Nakada, T.; Jiang, H.; Nakaguchi, T. An automatic detection approach of traumatic bleeding based on 3D CNN networks. IEICE Trans. Fundam. Electron. Commun. Comput. Sci. 2021, E104.A, 887–896. [Google Scholar] [CrossRef] [Scilit]
  17. Yang, L.; Nakaguchi, T.; Jiang, H.; Yang, T.; Kimura, H.; Arai, K.; Nakada, T.; Xuan, P. Traumatic bleeding detection based on fusion of 3D shape and local texture features. J. Clin. Med. Images 2021, 5, 1–12. [Google Scholar]
  18. Nurfauzi, R.; Baba, A.; Nakada, T.; Nakaguchi, T.; Nomura, Y. Automated detection of traumatic bleeding in CT images using 3D U-Net# and multi-organ segmentation. Biomed. Phys. Eng. Express 2025, 11, 025026. [Google Scholar]
  19. Shen, X.; Zhou, Y.; Shi, X.; Zhang, S.; Ding, S.; Ni, L.; Dou, X.; Chen, L. The application of deep learning in abdominal trauma diagnosis by CT imaging. World J. Emerg. Surg. 2024, 19, 17. [Google Scholar] [CrossRef] [Scilit]
  20. Assis, Y.; Liao, L.; Pierre, F.; Anxionnat, R.; Kerrien, E. Intracranial aneurysm detection: An object detection perspective. Int. J. Comput. Assist. Radiol. Surg. 2024, 19, 1667–1675. [Google Scholar] [CrossRef] [Scilit]
  21. Chen, L.C.; Papandreou, G.; Kokkinos, I.; Murphy, K.; Yuille, A.L. DeepLab: Semantic image segmentation with deep convolutional nets, atrous convolution, and fully connected CRFs. IEEE Trans. Pattern Anal. Mach. Intell. 2018, 40, 834–848. [Google Scholar] [CrossRef] [Scilit]
  22. Nomura, Y.; Miki, S.; Hayashi, N.; Hanaoka, S.; Sato, I.; Yoshikawa, T.; Masutani, Y.; Abe, O. Novel platform for development, training, and validation of computer-assisted detection/diagnosis software. Int. J. Comput. Assist. Radiol. Surg. 2020, 15, 661–672. [Google Scholar] [CrossRef] [Scilit]
  23. Wasserthal, J.; Breit, H.C.; Meyer, M.T.; Pradella, M.; Hinck, D.; Sauter, A.W.; Heye, T.; Boll, D.T.; Cyriac, J.; Yang, S.; et al. TotalSegmentator: Robust segmentation of 104 anatomic structures in CT images. Radiol. Artif. Intell. 2023, 5, e230024. [Google Scholar] [CrossRef] [Scilit]
  24. He, K.; Zhang, X.; Ren, S.; Sun, J. Deep residual learning for image recognition. In Proceedings of the 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), Las Vegas, NV, USA, 27–30 June 2016; pp. 770–778. [Google Scholar]
  25. Redmon, J.; Divvala, S.; Girshick, R.; Farhadi, A. You only look once: Unified, real-time object detection. In Proceedings of the 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), Las Vegas, NV, USA, 27–30 June 2016; pp. 779–788. [Google Scholar]
  26. Ronneberger, O.; Fischer, P.; Brox, T. U-net: Convolutional networks for biomedical image segmentation. In Lecture Notes in Computer Science, Proceedings of the Medical Image Computing and Computer-Assisted Intervention–MICCAI 2015: 18th International Conference, Munich, Germany, 5–9 October 2015; Proceedings, Part III 18; Springer: Cham, Switzerland, 2015; pp. 234–241. [Google Scholar]
  27. Neubeck, A.; Van Gool, L. Efficient non-maximum suppression. In Proceedings of the 18th International Conference on Pattern Recognition (ICPR’06), Hong Kong, China, 20–24 August 2006; pp. 850–855. [Google Scholar]
  28. Chakraborty, D.P.; Berbaum, K.S. Observer studies involving detection and localization: Modeling, analysis, and validation. Med. Phys. 2004, 31, 2313–2330. [Google Scholar] [CrossRef] [Scilit]
  29. Samuelson, F.W.; Petrick, N. Comparing image detection algorithms using resampling. In Proceedings of the IEEE International Symposium on Biomedical Imaging (ISBI), Arlington, VA, USA, 6–9 April 2006; pp. 1312–1315. [Google Scholar]
  30. Shaukat, F.; Raja, G.; Frangi, A.F. Computer-aided detection of lung nodules: A review. J. Med. Imaging 2019, 6, 020901. [Google Scholar] [CrossRef] [Scilit]
  31. Yu, S.M.; Young, C.Y.M.; Chan, Y.H.; Chan, Y.S.; Tsoi, C.; Choi, M.N.Y.; Chan, T.H.; Leung, J.; Chu, W.C.W.; Hung, E.H.Y.; et al. Artificial intelligence-based computer-aided diagnosis for breast cancer detection on digital mammography in Hong Kong. Hong Kong Med. J. 2024, 30, 468–477. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  32. Sierink, J.C.; Treskes, K.; Edwards, M.J.R.; Beuker, B.J.A.; Den Hartog, D.; Hohmann, J.; Dijkgraaf, M.G.W.; Luitse, J.S.K.; Beenen, L.F.M.; Hollmann, M.W.; et al. REACT-2 study group. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): A randomised controlled trial. Lancet 2016, 388, 673–683. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  33. Banaste, N.; Caurier, B.; Bratan, F.; Bergerot, J.-F.; Thomson, V.; Millet, I. Whole-body CT in patients with multiple traumas: Factors leading to missed injury. Radiology 2018, 289, 374–383. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  34. Sarkar, N.; Kumagai, M.; Meyr, S.; Pothapragada, S.; Unberath, M.; Li, G.; Ahmed, S.R.; Smith, E.B.; Davis, M.A.; Khatri, G.D.; et al. An ASER AI/ML expert panel formative user research study for an interpretable interactive splenic AAST grading graphical user interface prototype. Emerg. Radiol. 2024, 31, 167–178. [Google Scholar] [CrossRef] [Scilit]
  35. Takaishi, T.; Kokubo, Y.; Kondo, K.; Matsumoto, K.; Yamamoto, T.; Shibata, S.; Owatari, Y.; Nariyuki, F.; Kawai, T.; Hiwatashi, A. Automated detection and classification of adrenal masses on CT using two annotation methods: Segmentation vs. bounding box. Eur. J. Radiol. Artif. Intell. 2025, 1, 100003. [Google Scholar] [CrossRef] [Scilit]
  36. Zhong, Y.; Xu, Z.; Han, C.; Liu, Z.; Wang, Y. Bounding boxes for weakly-supervised breast cancer segmentation in DCE-MRI. Biomed. Signal Process. Control. 2025, 105, 107656. [Google Scholar] [CrossRef] [Scilit]
  37. Kalantar, R.; Hindocha, S.; Hunter, B.; Sharma, B.; Khan, N.; Koh, D.-M.; Ahmed, M.; Aboagye, E.O.; Lee, R.W.; Blackledge, M.D. Non-contrast CT synthesis using patch-based cycle-consistent generative adversarial network (Cycle-GAN) for radiomics and deep learning in the era of COVID-19. Sci. Rep. 2023, 13, 10568. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.