Abstract
In the high Andean regions of Peru, above 3500 m a.s.l., selecting a roofing system requires balancing budgetary constraints, technical performance, and environmental impacts under severe frost and demanding climatic conditions. This study compared several roofing alternatives from a comprehensive perspective to determine the most suitable solution by simultaneously considering economic, environmental, and social criteria. For this purpose, the Integrated Value Model for Sustainable Assessment (MIVES)—a multi-criteria decision-making methodology—was employed to evaluate five systems: traditional ichu thatched roof (ITR), ceramic tile (CT-II), corrugated galvanized steel with insulation (CGS-II), fiber cement with insulation (FC-II), and sandwich panel with an insulating core (PIR-SP). The model was implemented using a requirements tree with 11 indicators and its stability was assessed through a sensitivity analysis involving five weighting configurations. The overall sustainability indices ranked ITR first (0.697), primarily due to its low carbon footprint and favorable thermal performance. It was followed by CT-II (0.632), due to its superior landscape integration; CGS-II (0.602), owing to its cost-effectiveness; FC-II (0.586), for its balanced environmental profile; and finally, PIR-SP (0.504), which excelled in industrial efficiency and construction speed despite a higher environmental impact. In summary, the results indicated that vernacular solutions minimized environmental impacts and optimized local resources, whereas industrialized options were preferable when durability and assembly times were prioritized. The sensitivity analysis, with variations below 5%, supported the model’s consistency as a decision-support tool and its potential to guide policies for sustainable social housing in high-mountain contexts.
1. Introduction
The high-altitude Andean regions of Peru are characterized by extreme climatic conditions, with elevations exceeding 3500 m.a.s.l, where nighttime temperatures drop below 0 °C, even reaching as low as −28.2 °C [1,2,3] (see Figure 1b). These conditions pose a serious challenge to the habitability of rural housing, as supported by previous studies on the predominant building materials and systems in Andean dwellings. Here, uninsulated adobe walls and metal sheet roofs provide an inadequate thermal response, resulting in extremely low indoor temperatures similar to those outdoors [4,5,6]. Thus, the combination of exposure to the extreme cold, high incidence of respiratory diseases, and increased mortality heightens the vulnerability of populations with low socioeconomic resources and limited access to heating means [7,8,9].
Figure 1.
Populated center of Imata, Arequipa. This locality, situated in the high Andean region of Arequipa, is one of the study sites for this research. The image shows: (a) a general view of the roofs in the populated center of the study sites for this research; (b) the presence of snow on the roofs.
In response to this issue, a wide variety of roofing system alternatives with potential for use in the high Andean context are available. On the one hand, there are industrialized traditional solutions such as corrugated galvanized steel roofing (calamina), a widely used material due to its low initial cost and ease of installation; however, it is criticized for its high thermal conductivity, which exacerbates heat loss [2,10], as well as fiber cement with integral insulation and polyisocyanurate (PIR-SP) insulating panels. On the other hand, ceramic tile roofing with integral insulation also persists [11], along with traditional solutions such as Stipa ichu thatch, a vernacular material with good thermal performance and cultural significance. Its use has declined, however, due to its low durability and the need for annual maintenance, and it is being progressively replaced by industrialized options [8,12,13]. This material transition, driven by practical and regulatory factors [12], has not necessarily been accompanied by a systematic evaluation of its overall performance under extreme climatic conditions.
The high Andean context of rural housing in the study area of Arequipa (Peru) presents a duality of challenges and opportunities (see Figure 1). The challenges include low population density, limited and costly access to industrialized materials, a scarcity of specialized labor, and severe economic constraints that prioritize initial cost over long-term performance [14,15]. However, this same context offers unique opportunities for sustainable innovation: the potential for more flexible planning, the integration of local knowledge and community practices, and, crucially, the possibility of using local materials. These materials not only reduce costs and the environmental footprint but are often better suited for bioclimatic adaptation and reinforce cultural identity [16,17,18]. Self-building, a common practice in these areas, can be transformed from a risk factor into an opportunity for technological appropriation and the development of context-specific solutions within the study area [14].
Therefore, this study focuses specifically on the roof or covering system as a critical constructive element for the sustainability of high Andean housing. The justification is multifaceted: (1) Thermally, the roof is consistently identified as the component of the building envelope with the greatest impact on heat loss and gain due to its direct exposure to solar radiation and cold night air [8,19,20]. (2) Structurally, it defines the dwelling’s integrity and durability against rain, hail, and wind. (3) From an economic and environmental perspective, selecting the optimal roofing material involves decisions regarding initial investment, life-cycle cost, resource consumption, and waste generation [11,19]. (4) Socially and culturally, the materiality of the roof carries deep symbolic meaning that influences community acceptance of the proposed solutions [12,20]. Consequently, optimizing the roof constitutes a key point for holistically improving habitability.
Comparative research on roofing systems in extreme climates has advanced significantly worldwide, employing diversified methodologies according to the climatic context. However, there is a scarcity of comprehensive studies for extreme cold climates. In these contexts, critical variables such as heat retention, life cycle, and resilience to freeze–thaw cycles have been scarcely addressed compared to warm or temperate climates [21]. Internationally, methodological advances have diversified based on climatic context: in arid zones, such as Saudi Arabia, mixed approaches have been developed integrating energy numerical simulations (EnergyPlus/DesignBuilder) with social perception assessments using Likert surveys and statistical analysis [22]; in humid tropical climates, like Singapore, advanced numerical models validated with experimental testing predominate [23]; and for urban heat island analysis during extreme events (Melbourne), mesoscale climate models coupled with urban parameters are used [24]. Regarding Mediterranean contexts with strict regulatory and performance requirements, as in Europe, standardized life-cycle analyses (LCA) comparing only flat roof systems are common [21]. In contrast, research in Peru has focused on cold high Andean climates, with experimental studies evaluating the thermal behavior of traditional roofs (straw/ichu, corrugated metal) and improved solutions [25,26,27,28].
However, these studies are primarily limited to the analysis of environmental variables (temperature, thermal conductivity, transmittance), overlooking social indicators (perception, cultural acceptance) and economic dimensions (cost and performance). This methodological gap highlights the need for holistic approaches that go beyond technical–environmental aspects to incorporate socioeconomic criteria for a sustainable assessment in extreme regions such as the Andes. A summary of the main research and methodologies from the reviewed literature is presented in Table 1.
Table 1.
Comparative studies of roofing systems in extreme climates.
To address the complexity of selecting the optimal roof system that integrates technical, economic, environmental, and social dimensions, this study adopts the three pillars of a sustainability paradigm and employs the MIVES methodology (Integrated Value Model for Sustainable Assessments). The MIVES method is a rigorous and flexible multi-criteria decision-making (MCDM) tool, which enables the integration of heterogeneous quantitative and qualitative indicators into a global sustainability index [29,30] through value functions and weighting. Its evolution and application over the last decade have established it as a key tool for holistic assessments in civil engineering and architecture, overcoming the limitations of methods such as the life-cycle assessment (LCA) by explicitly incorporating social and economic dimensions [31]. Its effectiveness has been demonstrated and validated in recent research within contexts similar to the high Andean region, such as the evaluation of reinforced adobe techniques for reconstruction [32], the selection of building systems for self-built rural housing [14], and the analysis of sustainability in the adaptive reuse of heritage [20].
Consequently, this research seeks to answer the central question: what is the most suitable roofing system for housing in the high-altitude regions of Peru, characterized by an extremely cold climate and for a population with economic constraints? Therefore, the objective of this work is to determine the optimal solution from a holistic perspective. This will be achieved through a comparative economic, environmental, and social assessment of roof alternatives with integral insulation corrugated galvanized steel sheet (CGS-II), fiber cement (FC-II), ceramic tile (CT-II), metal sandwich panel with a polyisocyanurate core (PIR-SP), and ichu thatched roof (ITR), using the specific conditions of the high Andean zone of the Arequipa region as a reference. This area, representative of the Peruvian Andes, presents the ideal environmental and socioeconomic context for the analysis. The use of systematic decision-support methodologies in the Peruvian construction sector still has gaps, but it is essential for guiding public policies, as established by the objectives of the national housing policy. It should be noted that the main contribution of this work lies in the application of the MIVES method to unify economic, environmental, and social variables into a single index, facilitating transparent and technically grounded decision-making, thereby contributing to the scarce specialized literature on roof selection in high-altitude rural contexts [33,34]. This methodology is designed to be adapted and replicated in high-altitude contexts with characteristics similar to those of the study area.
This article is structured as follows: Section 1 presents the introduction, contextualizing the problem; Section 2 details the MIVES methodology adapted for this case study; Section 3 explains the case study methodology, including the requirements tree, indicators, value functions, and weightings; Section 4 presents the evaluation model; Section 5 presents and discusses the results of the comparative analysis; and finally, Section 6 provides the conclusions and recommendations of the study.
2. Methodology
To address the complexity of selecting the most suitable roofing system in high Andean zones, this research adopts a holistic perspective that integrates the economic, environmental, and social dimensions the fundamental pillars of sustainability by employing the MIVES methodology (Integrated Value Model for Sustainability Assessments). This multi-criteria decision-making method is based on multi-attribute utility theory, which enables the integration of heterogeneous indicators into a single comparable sustainability index [30]. Its primary advantage lies in its flexibility to incorporate both qualitative and quantitative variables through value functions, making it an ideal tool for comprehensive evaluations in the field of sustainable construction [29,35].
Previous research has successfully applied MIVES to diverse construction technologies, such as reinforced adobe in seismic zones [36,37], school systems [31], trusses in sports halls [38], piping systems [39], and post-disaster housing [35]. It has also been utilized for self-built housing [40], concrete columns [41], and reinforcement fibers [41]. However, none of these cases have addressed the specific alternatives and unique context of this research project. The methodology was structured in three main stages consistent with the standard MIVES application [29,30]. The first stage defined the scope and preselected technically viable alternatives for the extreme climatic conditions using boundary conditions.
The second stage involved constructing the decision model. A requirements tree was established with economic (R1), environmental (R2), and social (R3) pillars [20,32]. Subsequently, experts assigned normalized weights to reduce subjectivity [29], and value functions were defined to transform the original values into a dimensionless 0–1 scale based on the technical literature [29,38]. Finally, the third stage calculated the sustainability indices (SIs) via a weighted average, providing a holistic tool to support public policy decision-making in high Andean habitability projects, the entire process is summarized in Figure 2.
Figure 2.
Schematic representation of the MIVES in the case study. The image shows the stages from the selection of alternatives, the evaluation of the model, to the final calculation of the sustainability index.
Despite the usefulness of the MIVES method for decision-making, it has limitations and disadvantages, such as the inherent subjectivity in its structure, particularly in assigning weights to criteria, and a high dependence on the quality and availability of data for each indicator. This is precisely why, to quantify and verify the impact of these limitations, a sensitivity analysis is employed [42,43,44]. This approach validates the robustness of the conclusions by systematically varying key parameters, such as the weighting ranges, to test the stability of the results against underlying value judgments.
3. Case Study
The study is located in the high Andean region of Arequipa (Peru). Three rural population centers, which together define the evaluated area, are considered as representative case studies for the analysis: Imata (Caylloma province), San Juan de Tarucani (Arequipa province), and Chalhuanca (Yanque district, Caylloma province). These are high-altitude settlements where self-built housing, dispersed urban areas, and other characteristics typical of the high Andean centers of southern Peru, generally above 4000 m above sea level, are common [45].
From a climatic perspective, the region under study is distinguished by very low temperatures linked to the “Sierra Alta” (high mountains) and frequent frosts. At elevations exceeding 4000 m above sea level, SENAMHI regional data for high Andean stations in Arequipa (such as Crucero Alto, Imata, Pillones, and Patahuasi) document high occurrences of frost and minimum temperatures below 0 °C [46]. Furthermore, the research location is significantly exposed to solar radiation (including UV) due to the influence of the altitude, which leads to a noticeable daily temperature range that conditions the roofs’ performance [47]. Accordingly, districts that encompass the study region fall into pertinent categories of frost susceptibility according to low-temperature risk scenarios [48]. The study area’s climatic representativeness as a demanding setting for the thermal performance of the building exterior is supported by the convergence of regional meteorological records and risk assessments (see Figure 3).
Figure 3.
Study area and contextual characterization of Imata, San Juan de Tarucani, and Chalhuanca (Arequipa, Peru). The infographic includes: (i) a regional map of minimum temperature (P10) based on CENEPRED–SENAMHI data, with the temperature ranges and locations of the three population centers; (ii) satellite views of each settlement; and (iii) a set of key socio-environmental indicators (altitude, population size, poverty, predominant economic activity, exposure to frost, and levels of solar radiation) used to describe the climatic and vulnerability context that supports the comparison of roof replacement alternatives.
The Imata weather station (4519 m above sea level) is used as a reference to characterize the thermal context of the study with a homogeneous baseline: (i) it is a member of a group of high Andean stations with reported and verifiable information at the regional level (including SENAMHI regional bulletins); and (ii) it has served as a basis of support for technical studies on thermal performance and envelope improvements in high Andean housing developed in Imata (experimental modules and simulations) [46,49,50]. While the populations of the three locations that comprise the study area have been taken into account to address the social characterization of the area, this decision does not limit the case’s scope to a single location. Instead, it permits the comparison of alternatives under a common framework of climate severity.
In the high Andean rural areas of Peru, self-built single-family homes of one or two stories are predominant, characterized by earthen walls (adobe and/or rammed earth) and lightweight roofs of corrugated metal sheets mounted on wooden frames [2,4,8,51]. This construction typology has been used as a reference in technical evaluations and thermal performance simulations for high Andean housing [2,4,49,50]. Field measurements, evaluations in experimental modules, and simulations carried out in this context show that, even after incorporating basic passive improvements, the combination of building envelopes with low thermal insulation and thin metal roofs exposed to sub-zero outdoor temperatures generates persistently cold interior environments, with nighttime temperatures close to 0 °C and prolonged periods of thermal discomfort [4,5,49,50,51].
In parallel, the progressive replacement of traditional thatched roofs (ichu grass) with corrugated metal sheets has been observed in Andean rural settlements, driven by the perceived greater durability, lower maintenance requirements, and ease of installation of metal roofing, which tends to standardize roofing materials in these territories [2,51]. While there are academic initiatives and public programs aimed at improving Andean housing [2,52], the published evidence is mostly concentrated in case studies and specific proposals, with comprehensive comparisons of construction alternatives performed under explicit multi-criteria and with sustainability approaches being less frequent [2,4,8].
Based on this context, five roofing systems available in the local market and compatible with roof replacement or improvement interventions are evaluated: corrugated galvanized steel sheet with integral insulation (CGS-II), fiber cement with integral insulation (FC-II), ceramic tile with integral insulation (CT-II), metal sandwich panel with polyisocyanurate core (PIR-SP), and ichu thatched roof (ITR). Subsequently, a MIVES model is built to integrate economic, environmental, and social attributes into a global sustainability index, supporting decision-making in future actions to improve roofs in high Andean rural housing [32,52].
3.1. Boundary Conditions (BC)
For any roofing option to be included in the research, it must meet the minimum technical criteria (boundary conditions). These requirements serve as an initial filter in the MIVES methodology, defining the range of options to be evaluated and ensuring that the alternatives are similar in terms of the three aspects of sustainability and consistent with the context of the research [32]. In this work, two boundary conditions (BC1–BC2) are developed:
Minimum thermal comfort conditions (BC1): All roofing options must be able to provide a structural section that helps reduce the thermal discomfort observed in homes in the high Andes [2,4,8,49]. From an operational point of view, the alternative must not pose a risk of surface or interstitial condensation under the climatic conditions of the case study, and it must be able to achieve an overall thermal transmittance equal to or lower than the reference value adopted for study area (U ≤ 0.50 W/m2·K) using appropriate thicknesses and combinations of materials. The calculation methods of standards EN ISO 6946 and EN ISO 13788 are used to verify these requirements.
Given the frequency of severe frosts and the requirement to provide observable thermal benefits over standard solutions, the value U ≤ 0.50 W/m2·K is chosen as the performance criterion for the study area. This threshold is used to maintain consistent functional equivalency between alternatives and is more stringent than the maximum reference values of RNE EM.110 for roofs in the high Andean (U roof ≤ 0.83 W/m2·K) and snowy (U roof ≤ 0.80 W/m2·K) zones. Its order of magnitude is consistent with studies on envelope improvement in rural high Andean housing in Southern Peru [8].
Replacement of roof covering on existing load-bearing structure (BC2): Roof alternatives must be able to be used as a replacement intervention on the current primary load-bearing structure (such as trusses or main beams and purlins, made of wood or steel), without necessitating the replacement of the main structural system or significant increases in load that would necessitate modifications to load-bearing elements, in order to guarantee the analysis’s applicability in rural high Andean housing improvement programs. In addition to allowing for the consistent depiction of the effects of maintenance, repair, and replacement throughout the study period, this condition directs the comparison toward solutions compatible with incremental interventions, rural logistics, and supported self-construction [53].
Table 2 summarizes the evaluated roofing systems, their acronyms, construction solutions, and compliance with BC1–BC2. Consequently, CGS-II, FC-II, CT-II (with insulation and hygrothermal components), PIR-SP, and ITR are incorporated into the MIVES model. RCS, although considered, does not comply with BC1 without continuous insulation and additional layers, and is not compatible with BC2 as it requires a change in structural typology; therefore, it is excluded.
Table 2.
Present or potentially applicable roofing systems.
The alternatives that pass the boundary conditions’ filter are briefly described below:
Corrugated galvanized steel sheets (CGS-II): Supported by a lightweight hardwood frame, these are a widely used option in rural Andean housing. However, because of the low thermal inertia and high thermal transmittance, 70 mm mineral wool thermal insulation (λ = 0.035 W/m·K; R = 2.00 m2·K/W), a ventilated air sublayer connected to the battens (50 mm ventilated chamber), and hygrothermal components (see Figure 4a) are required to prevent thermal discomfort brought on by cold nights [5,66]. The system satisfies the accepted transmittance threshold (U = 0.47 W/m2·K) with this configuration.
Figure 4.
Roof systems selected for the case study: (a) CGS-II, (b) FC-II, (c) CT-II, (d) PIR-SP, and (e) ITR. The stratified composition of each system is summarized in Table 3.
Table 3.
Composition of present or potentially applicable roofing systems.
Corrugated fiber cement boards (FC-II): These are widely used as an economical roofing solution in both urban and rural buildings. This study especially examines asbestos-free corrugated fiber cement sheets in compliance with product specifications and examined environmental statements. Because of their low inertia and moderately high thermal conductivity, these sheets require hygrothermal components, 60 mm mineral wool thermal insulation (λ = 0.035 W/m·K; R = 1.71 m2·K/W), and a ventilated air sublayer connected to the battens (50 mm ventilated chamber) in order to achieve acceptable levels of comfort in areas that frequently experience frost (see Figure 4b). Transmittance is therefore still within the functional equivalency threshold (U = 0.49 W/m2·K). The availability of environmental product declarations for fiber cement produced in compliance with standard EN 15804 facilitates its inclusion in life-cycle assessments [5,54,66].
Ceramic tiles (CT-II): When laid over hardwood boards or battens, ceramic tiles add thermal mass and deliver an architectural expression commonly linked to permanent dwellings. In order to improve the hygrothermal performance of the assembly, a vented air sublayer connected to the battens (50 mm ventilated chamber) and a tile thickness of 10 mm (lower thermal resistance layer than the insulation) are taken into consideration. In order to reach the transmittance threshold (U = 0.48 W/m2·K), this is supplemented by hygrothermal components and 50 mm mineral wool thermal insulation (λ = 0.035 W/m·K; R = 1.43 m2·K/W) (see Figure 4c); however, the system’s weight increases structural requirements and calls for more skilled labor [5,51,66].
Metal sandwich panel with PIR core (PIR-SP): By integrating a low thermal conductivity insulating core between two metal sheets, these systems achieve low thermal transmittance with moderate thicknesses (see Figure 4d). With λ = 0.023 W/m·K (R = 4.35 m2·K/W) and a thickness of 100 mm, the PIR core in this instance achieves a much lower transmittance (U = 0.22 W/m2·K). Due to the information available on its thermal performance, expected service life, and environmental product declarations, it is a relevant alternative for comparing high thermal performance solutions within the MIVES model, even though its use in rural high-altitude Andean dwellings is still in its early stages [54,67].
Ichu thatched roof (ITR): This is accomplished by applying layers of Stipa ichu on a secondary substructure. When set up to satisfy the transmittance threshold and condensation criteria specified in BC1, this traditional method has great local relevance and high prospective thermal performance. A 50 mm ventilated cavity made of battens is utilized in conjunction with 200 mm of ichu with a thermal conductivity of λ = 0.048 W/m·K (R ≈ 4.17 m2·K/W) to guarantee U ≤ 0.50 W/m2·K. Under the same functional equivalency criterion, this arrangement maintains comparability with an estimated transmittance of U = 0.23 W/m2·K. It is a viable option among roof replacement options due to its availability in the high Andean climate and its cultural roots [5,51].
Lightweight slabs are frequently marketed as an improvement over lightweight roofs in high Andean environments like Imata. However, because of their monolithic nature and higher permanent load, they necessitate a specifically dimensioned load-bearing support and structural solution, making them more of a change in structural typology than a roof replacement. Additionally, it does not meet the functional equivalency level set in BC1 (U ≤ 0.50 W/m2·K) due to its high thermal transmittance (U ≈ 3.5 W/m2·K) in its normal design without continuous insulation. As a result, it is not covered by the boundary condition BC2 and is likewise excluded by BC1.
3.2. Characterization of the Roofing Systems
The economic, environmental, and social information of the roofing systems is organized in Figure 5, which displays their specific performance parameters. These data feed into the model’s requirements tree, enabling the multi-criteria comparison of the different construction alternatives.
Figure 5.
MIVES indicator structure applied to the roofing options (CGS-II, FC-II, CT-II, PIR-SP, and ITR). The diagram outlines the economic, environmental, and social indicators used as input data for the multi-criteria evaluation.
3.2.1. Economic Indicators (R1)
The economic evaluation of roofing in high Andean areas integrates four interrelated indicators, grouped into two main criteria: cost (C1) and time (C2). The cost criterion comprises the initial value per square meter (I1) which establishes the base cost and varies according to the system’s level of technification; and local availability (I2) as measured in kilometers from the distribution centers, reflecting logistical expenses. The time criterion includes durability (I3), or estimated useful life in years, which is severely affected by extreme weather conditions and impacts the life-cycle cost; and installation performance (I4) as measured in square meters per day, determining labor productivity. The joint analysis of these factors is essential to identify the most cost-effective solutions in this specific environment.
Value Per m2 (I1)
The cost analysis per square meter is based on the local market quotations and standardized unit price data from the Peruvian Chamber of Construction (CAPECO) [68] and the Peruvian journal Costos [69], which reflect prices for the year 2025. Labor, material, and equipment costs are quantified for the five roof typologies. The following base construction costs are established: €31.22/m2 for a corrugated galvanized steel sheet roof (CGS-II), characterized by the use of standardized materials, such as zinc sheets and wooden supports, combined with unskilled labor; €49.05/m2 for a ceramic tile roof (CT-II), which requires skilled labor and materials such as wood and mortar; €41.18/m2 for an ichu thatched roof (ITR), which uses locally available materials like ichu and wood sourced nearby, lowering transportation costs; €62.50/m2 for a corrugated fiber cement roof (FC-II), where materials are industrialized and labor is semi-skilled; and €79.60/m2 for a sandwich panel roof (PIR-SP) with a metallic structure, representing the highest cost due to the specialized materials and installation by skilled labor. The total cost values include both the initial installation cost and the maintenance cost according to the durability of each material. A comparative value per m2 of the roofing systems evaluated is presented in Figure 6.
Figure 6.
Comparative value per m2 of roofing systems. The graph presents the total costs for the five systems (FC-II, CT-II, CGS-II, PIR-SP, and ITR), including the initial installation and maintenance costs.
Local Availability (I2)
To determine the local availability of each roof covering typology, the maximum distance from the study areas to the nearest distribution point was calculated. Locally sourced materials, such as wood for the roof support structures, can generally be obtained within an 80 km radius from valleys and rural areas. Among the analyzed systems, the ichu thatched roof (ITR) shows the highest degree of local integration, as ichu grass can be easily found nearby, hence a distance of 15 km is considered. In contrast, corrugated galvanized steel sheets (CGS-II), which use common materials like nails, black wire, and hand tools, can be purchased from local hardware stores within an 80 km radius, while ceramic tiles (CT-II) can be sourced from larger suppliers within a 150 km range. Industrialized materials, such as fiber cement sheets (FC-II) and metal profiles, are mainly available in urban centers at distances of 150 km. The metal sandwich panel (PIR-SP) depends on specialized components, which must be acquired from national suppliers, involving delivery times and distances of 150 km.
Durability (I3)
The durability of the different roofing systems in high-altitude Andean environments is determined by environmental conditions and the intrinsic properties of the materials used. Ichu thatched roofs (ITRs), for example, require a complete replacement every 7 years [70] due to their low durability under extreme climatic conditions, highlighting the limitations of organic materials in such environments. In the case of corrugated galvanized steel sheet roofs (CGS-II), studies [71] indicate that extreme environmental conditions such as high UV radiation, thermal amplitude, and seasonal humidity can reduce their service life, which is initially estimated to be 20 to 25 years. On the other hand, metal sandwich panel roofs (PIR-SPs) can achieve a service life of up to 50 years under controlled conditions, although their performance is affected by the exposure to freeze–thaw cycles and UV radiation [72,73]. Regarding ceramic tile (CT-II) and fiber cement (FC-II) roofs, studies such as [72,74] report a service life of 30 to 40 years in temperate and extreme climates. However, in high-altitude Andean environments, the combination of acid precipitation, freeze–thaw cycles, and UV radiation similarly accelerates degradation, thereby reducing their mechanical strength.
Productivity (I4)
Productivity rates were obtained based on standards established by the Peruvian Chamber of Construction (CAPECO) [68] and local specialized publications, such as the journal “Costos” [69]. For the roof installation, daily rates (m2/day) are defined according to the system’s complexity: 25 m2 for sandwich panels (PIR-SP), 14 m2 for corrugated fiber cement (FC-II), 20 m2 for corrugated galvanized steel sheets (CGS-II), 11 m2 for an ichu thatched roof (ITR), and 8 m2 for ceramic tiles (CT-II). These values reflect the productivity of a mixed work crew comprising both skilled personnel (operators and technicians) and unskilled laborers, considering factors such as altitude, material logistics, and typical highland weather conditions which can influence work efficiency. In the specific case of ichu thatched roof (ITR), its installation relies on semi-skilled labor with traditional knowledge, and its productivity is affected by material availability and moisture conditions during its placement. The most significant variation lies in productivity. Industrialized systems such as metal sandwich panels (PIR-SP) demonstrate higher productivity compared to ceramic tiles (CT-II). This difference is due to the technological level of the roofing system and the skilled labor required. The evaluation of economic indicators for each roofing are summarized in Table 4.
Table 4.
Evaluation of economic indicators for roofing per square meter (m2).
3.2.2. Environmental Indicators (R2)
The environmental branch (R2) consists of three criteria: emissions (C3), non-renewable energy (C4), and water resources (C5). The carbon footprint (I5), energy consumption (I6), and water footprint (I7) metrics are used to apply these requirements, respectively. Everything is contained inside a 1 m2 functional unit of thermally equivalent roofing. These indicators are measured using environmental product declarations (EPDs) [55,56,57,63,67,75,76,77,78], databases that adhere to the standard EN 15804:2012+A2:2019 [54] as well as the principles of ISO 14040 and ISO 14044 for life-cycle assessments (LCAs) [64,65], as per the ILCD Handbook [79] and the level(s) framework [80]. The standards ensure that the scope is established across the roofing system’s whole life cycle in compliance with EN 15804+A2 [54], including the production, construction, usage, and end-of-life stages through scenarios that align with the research. In order to ensure methodological consistency with the remainder of the LCAs, transport to the site is specifically computed using characteristics representative of the case setting (distances, logistics, and local conditions). The D module, which relates to advantages and disadvantages outside the system boundary, is also given if applicable. This enables a consistent evaluation of alternatives with a similar thermal performance (U ≤ 0.50 W/m2·K), which are computed in accordance with EN ISO 6946 [81] and hygrothermally confirmed using EN ISO 13788 [82]. The environmental effects of ichu thatched roofs (ITRs) were calculated using EPDs for plant coverings (cane/straw) as a reference and adjusted to the functional unit (1 m2) using the same conversion logic applied to the other options, keeping the LCAs’ scope unchanged [83,84].
Environmental product declarations (EPDs) have limitations related to the variability of Product Category Rules (PCRs), the geographic scope of the datasets, and the definition of transport, end-of-life, and Module D scenarios. These sources of uncertainty affect the accuracy of absolute values. Therefore, a homogenization strategy is applied using a common functional unit, and the results will be interpreted comparatively between the alternatives.
The Carbon Footprint (I5)
The global warming potential (GWP–GHG, kg CO2e) stated in the EPDs of the goods that comprise each roof is used to compute the carbon footprint in compliance with the standard EN 15804+A2 and LCA for building recommendations [54,64,65,76,77,79,80]. For the EPDs of the base layer of corrugated galvanized steel sheet, fiber cement, ceramic tile, and PIR-SP sandwich panel [56,58,60,61], their corresponding thermal insulation and service components (vapor control membrane, breathable membrane, battens for ventilated cavity, flashings, and fasteners) for each system are not included in the environmental declaration [55,57,62,63,67,75]. The PIR-SP panel is subject to the no double counting rule; as the insulating core and metal sheets are part of the panel’s EPD, only the finishes and fixings are included. Service components are incorporated in the CGS, FC, and CT according to their corresponding EPDs or comparable datasets [54,55,57,62,63,75,78,79]. The aggregate values per 1 m2 of roofing “with services” during the life cycle, taken into consideration in line with EN 15804+A2, are displayed in Table 5. In comparison, the ichu thatched roof (ITR) has the lowest carbon footprint; conversely, fiber cement has the lowest GWP among the industrialized options, while PIR-SP panels have the highest GWP, followed by corrugated iron and tiles.
Table 5.
Assessment of environmental indicators for 1 m2 of “serviced” roof.”.
Energy Consumption (I6)
According to the energy resource use categories of the standard EN 15804+A2 [54], energy consumption (MJ) is computed using the non-renewable primary energy values indicated in the EPDs of the base layers [56,58,60,61] and service components [55,57,62,63,75,78] as a source. The impacts are converted to 1 m2 of roofing, similar to indicator I5, using the mass or volume factors per m2 corresponding to each sublayer, thermal insulation, and service components (membranes, battens, flashings, fasteners) to ensure consistency with the construction solutions used in the thermal and condensation calculations. Double counting is avoided in the PIR panel, where the metal sheets and core are parts of the system’s EPD [54,56,61,79]. The energy consumption per square meter of roofing over the life cycle, taken into consideration in compliance with EN 15804+A2, is summarized in Table 5. The research shows that PIR-SP panels demand significantly more energy than fiber cement, calamina, and tiles, which are in the center. Among the manufactured options, fiber cement has the lowest energy consumption, while the ichu thatched roof (ITR) has the lowest embodied energy.
Water Footprint (I7)
The freshwater consumption (FW) listed in the EPDs for each roofing material is used to compute the water footprint in compliance with the water use categories of the standard EN 15804+A2 [78]. Water utilized as a process input (mixing, curing, washing, rolling, chilling, etc.) and, if feasible, water related to raw material and energy acquisition are considered [54,76,77,79]. The roofs are standardized to 1 m2 using the same characteristics as in I5 and I6. For the PIR panel and stratified systems, the requirement of no double counting is upheld using the EPDs of the base layers [55,56,58,60,61] and service components [55,57,62,63,75,78]. The FW results per 1 m2 throughout the life cycle, taken into consideration in compliance with EN 15804+A2, are displayed in Table 5. The ichu thatched roof (ITR) has the lightest water footprint among the choices analyzed, whereas fiber cement and tiles have much lower values within the industrialized group. The PIR-SP panel has the biggest water footprint, followed by calamina.
The functional unit adopted for the environmental and economic assessment corresponds to 1 m2 of complete roof system, including outer layer, thermal insulation and service components, complying with boundary conditions BC1 and BC2.
3.2.3. Social Indicators (R3)
To determine the representative sample size for the study site, required for quantifying the perception indicators I8 (thermal comfort), I9 (safety perception), I10 (landscape integration), and I11 (identification with materiality) for the MIVES model, the standard statistical formula for finite populations is applied. Equation (1) is defined as:
where, in the above:
- N: Is the total population size (516 inhabitants for Imata, 400 inhabitants for San Juan de tarucani,163 inhabitants for Chalhuanca according to the 2017 Population and Housing Census of INEI [45]).Z: Is the value corresponding to the desired confidence level (1.96 for 95%).p and q: Proportion of the population that possesses the characteristic of interest and its complement, respectively. Given the exploratory nature of the perception indicators, maximum variability was assumed (p = q = 0.5).
Consequently, a total sample size of 182 surveys was determined to be representative of the study area. This sample, which is representative of the study zone, is distributed as follows: 87 for Imata, 66 for San Juan de Tarucani, and 29 for Chalhuanca (see Figure 7).
Figure 7.
Surveys conducted in the Andes of Arequipa, Peru: (a) assessing safety perception using a sampling method; (b) conducting surveys to determine social indicators; (c) surveys conducted among local residents during their daily activities.
A unified scale from +100% to −100% is used to quantify the perception indicators, where +100% indicates unanimous acceptance, −100% unanimous rejection, and 0% a neutral or divided opinion. To assess social indicators, these are grouped into two main criteria: habitability (C6) and acceptance (C7). Four indicators are defined, calculated as the percentage difference between opposing responses: thermal comfort (I8) (“comfortable” vs. “uncomfortable”); safety (I9) (“safe” vs. “unsafe”); landscape Integration (I10) (“appropriate” vs. “inappropriate”); and identification with materiality (I11) (“belongs to the place” vs. “foreign”).
Perception of Thermal Comfort (I8)
For the study of thermal comfort perception, survey data are analyzed, evaluating the percentage differences between “comfortable” and “uncomfortable” ratings. The traditional ichu thatched roof (ITR) shows the highest positive difference (+28.02%), suggesting a recognition of its beneficial thermal properties in the local context. It is followed by the sandwich panel roof (PIR-SP) with a positive difference of +20.33%. The ceramic tile roof (CT-II) shows a positive difference of +19.52%, while the corrugated galvanized steel sheet (CGS-II) and fiber cement roofs (FC-II) show negative differences of −36.26% and −21.98%, respectively.
By evaluating these results, the differences can be attributed to the intrinsic properties of each material. The PIR panel, thanks to its greater thickness and structure, provides superior thermal insulation, reducing heat transfer and thus improving interior comfort. In contrast, a corrugated galvanized steel sheet (CGS-II) is a thin metallic material with high thermal conductivity, which creates unfavorable indoor conditions in extreme climates. This explains the high perception of discomfort in contrast to it being the predominant material among the surveyed population. As for fiber cement, it lacks sufficient thickness for adequate insulation, and thus it is perceived in the same way, while ceramic tiles, although perceived as adequate in the survey, are not widely used.
Perception of Safety (I9)
The perception of safety among the evaluated roofing systems show notable variations. The sandwich panel (PIR-SP) receive the most favorable rating (+42.86%), which could be attributed to its thickness and multilayer structure, conveying an image of solidity. In contrast, the traditional ichu thatched roof (ITR) registers a negative perception (−31.32%) associated with its vulnerability to extreme weather events (winds and hailstorms). The corrugated galvanized steel sheet (CGS-II), despite being predominant in the area, shows an unfavorable perception (−7.69%), possibly due to its thinness, propensity for noise, leaks, and damage from hail or wind. Similarly, fiber cement (FC-II), with a rating of −15.93%, is perceived as fragile. Finally, ceramic tiles (CT-II) generate a more favorable perception of +24.30% that is possibly associated with their robustness.
Landscape Integration (I10)
The survey results on landscape integration show a significant variation among the roofing materials. Ceramic tiles (CT-II) obtained the highest positive difference (+62.50%), possibly attributable to their color and texture which harmonize with the local traditional architecture. The traditional ichu thatched roof (ITR) also registers a favorable evaluation, with a difference of +21.43%, a result of its organic nature and visual coherence with the natural landscape. Meanwhile, the corrugated galvanized steel sheet (CGS-II) shows a clearly negative perception (−45.60%) associated with its propensity for corrosion and the consequent aesthetic deterioration. In contrast, fiber cement (FC-II) and sandwich panels (PIR-SP) obtain negative values of −14.30% and −7.69%, respectively The results are possibly due to their industrial appearance and the general lack of familiarity in the study area.
Identification with Materiality (I11)
The survey results show a clear cultural identification with corrugated galvanized steel sheet roofs (CGS-II), which is the predominant roofing type in the study area. This perception is reflected in the highest positive preference result recorded in the survey (+25.27%). Meanwhile, the traditional ichu thatched roof (ITR) also obtains a positive cultural valuation of +19.23%, reflecting its recognition as a vernacular material. Next, the ceramic tile roof (CT-II) shows a moderate degree of identification, with a positive result of +18.60%, although it is less than that of CGS-II. In stark contrast, contemporary systems such as fiber cement (FC-II) and sandwich panels (PIR-SP) present negative values of −38.20% and −21.98%, respectively, indicating that, despite their potential technical advantages, they are predominantly perceived as foreign elements. This difference reveals a significant gap between technological innovation and cultural acceptance in communities with a deeply rooted building heritage. Table 6 shows the evaluation of social indicators for the roof types studied.
Table 6.
Social indicator evaluation for roofs.
4. Evaluation Model
A process supported by the MIVES methodology is proposed, allowing for the calculation of a “sustainability index” for each construction technique based on a score ranging from 0.00 to 1.00. To achieve this, the value functions assigned to each indicator are summed to obtain a final dimensionless value. This enables the combination of qualitative and quantitative variables, as well as the comparison of results. The phases of this model are described below.
4.1. Development of the Requirements Tree
This is a branched diagram that includes the main and distinguishing elements to be examined. It groups the requirements, criteria, and indicators of the evaluation model, which correspond to the following categories: economic criteria of construction costs and timelines; environmental guidelines of emissions, non-renewable energy consumption, and water resource use; and social guidelines of habitability and acceptance. Figure 8 illustrates the final structure and components of the requirements tree.
Figure 8.
Requirements tree of the MIVES model. The hierarchical structure comprises three levels with the weights assigned by the panel of specialists mentioned in Table 7: requirements, decision criteria, technical indicators, and their measurement units.
4.2. Weighting and Assignment of Relative Weights
Subject matter experts are consulted to establish the corresponding weightings for each criterion and indicator through surveys and interviews. For this purpose, the direct percentage assignment method established in MIVES is used, ranging from 0 to 100% depending on the degree of relevance of each variable. This stage of the process is crucial as it ensures the evaluation and decision-making are as objective as possible. Table 7 displays the list of consulted experts, who are categorized based on two fields of expertise: (1) high-altitude Andean housing and (2) building technology and sustainability.
Table 7.
List of specialists consulted for the structure and weighting of the requirements tree.
As a result, the requirements tree is obtained with the necessary weightings at the level of requirements, criteria, and indicators, as shown in Figure 8. At the requirement level, the economic factor proves to be the most important at 41%, understood to be due to the high rates of poverty and vulnerability in the Andean region, which is broken down into costs (59%) and associated timelines (41%). This is followed by the environmental aspect, which reaches a value of 33%, driven by emission levels (38%), non-renewable energy consumption (35%), and water resource consumption (27%). Finally, the social aspect accounts for 26%, divided into habitability (55%) and acceptance (45%).
4.3. Assignment of Value Functions
The value function allows the quantification of an attribute or variable to be transformed into a dimensionless variable ranging from 0.00, representing minimum satisfaction (Smin), to 1.00, indicating the maximum degree of satisfaction (Smax). The primary purpose of this methodology is to enable the comparison of indicator assessments that have different units of measurement [85].
Variables such as time, cost, and indicators quantified by attributes, among others, can be compared. Thus, it is possible to perform a weighted sum of the various evaluations for each indicator. The value function used is determined through five parameters that, when modified, allow for a variety of shapes: S-shaped, linear, convex, or concave (see Figure 9). As shown in Equation (2), the parameters determining the function class are as follows: Ki, Ci, Xmax, Xmin, and Pi. The value of B is calculated from the five preceding values according to Equation (3) [44].
Figure 9.
Types of value function curves. They can be linear, concave, convex, and S-shaped depending on the data type and the concentration of quantities at the extremes or central parts [44].
- Xmín: The abscissa value yielding a score of 0 (for increasing value functions).Xmáx: The abscissa value yielding a score of 1 (for increasing value functions).X: The horizontal coordinate (abscissa) of the indicator being evaluated.Pi: The shape factor determining whether the curve is linear, convex, concave, or S-shaped. If Pi values are less than 1, concave curves are obtained; if greater than 1, they can be convex or S-shaped; and if equal to 1, they tend to be linear. Additionally, it approximates the slope of the curve at the inflection point with the coordinates (Ci, Ki).Ci: This approximates the abscissa value at the inflection point.Ki: This approximates the ordinate (y-coordinate) at the inflection point.B: The factor maintaining the function within the range of 0 to 1, as defined in Equation (2).
Table 8 presents the value functions for each indicator. It is important to note that the selected function fits the specific characteristics of each variable. The proposal includes: four linear functions, as values from 0 to 100% produce a proportional change regardless of the position on the abscissa; and seven S-shaped functions, since fluctuations in satisfaction (ordinate values) are more significant in the central values. Appendix A presents the value curves for the 11 indicators.
Table 8.
Parameters of the value functions for each indicator.
For example, indicator I2—local availability—exhibits a decreasing S-shaped value function, as satisfaction fluctuations (ordinate values) are more significant in the central values. Equations (4) and (5) are developed below using this indicator.
- X is the response to the evaluated indicator (local availability).Ki = 0.5 approximates the ordinate of the inflection point.Xmax = 300 km is the maximum abscissa value within the range of alternatives for the evaluated indicator.Ci = 150 km is the inflection point on the abscissa.Pi = 2.5 is the shape factor of the curve.B is the value that maintains the function within the 0 to 1 range. Factor B is defined in Equation (2), where Ki = 0.5; Xmax = 300 km; Xmin= 0 km (the minimum abscissa value within the range of alternatives for the evaluated indicator); Ci = 150 km; and Pi = 2.5. Figure 10 illustrates the development of this value function. The case of CT-II is taken as an example, where its distribution center is located 150 km from the study area. When evaluated in Figure 10, a Vi1 of 0.42 is obtained.Figure 10. Value function of indicator I2—local availability. This graph explains how dimensional data are transformed into dimensionless values using the S-shaped value function.
4.4. Quantification and Evaluation
To calculate the “sustainability index,” the following steps are required [55]:
Indicator values: These are generated using the value function to determine the score for each option. The alternative is quantified via the abscissa of the point on the value function curve, while the ordinate represents the value of the indicator for the alternative in question, as shown in Figure 11.
Figure 11.
Illustration of the transition from the technical quantification of indicators using value functions to the successive aggregation by levels (indicators, criteria, and requirements) using weighting coefficients (pi) to determine the final value index of the alternative.
Criteria values: These are calculated by multiplying the values of the indicators belonging to a specific criterion by their corresponding weights.
Requirement values: This is the sum of the values of the criteria associated with a single requirement, multiplied by their respective weights.
Value Index: This is obtained by summing the requirement values multiplied by their weigh.
As an example, the calculation process for the sustainability index of the CT-II technique will be explained, as detailed in Table 9. The process begins by providing the actual values obtained from Table 4, Table 5 and Table 6, which will be normalized (Vn) with the help of the MIVES 2.0 software. These values will be multiplied by the weights assigned in the requirements tree by the panel of specialists, as mentioned in Figure 8. Appendix B details the calculation of the sustainability index for the five techniques in this study.
Table 9.
Calculation breakdown of the sustainability index for the CT-II technique.
For a better understanding, the operations performed based on the data in Table 9 are shown below.
| ECONÓMIC-R1 = 0.41 ⟨0.59 × [0.55 × 0.66 + 0.45 × 0.42] + 0.41 × [0.59 × 68 + 0.41 × 28]⟩ = 0.220 |
| ENVIRONMENT-R2 = 0.33 ⟨0.38 × [1.00 × 0.71] + 0.35 × [1.00 × 0.60] + 0.27 × [1.00 × 0.95]⟩ = 0.243 |
| SOCIAL-R3 = 0.26 ⟨0.55 × [0.51 × 0.59 + 0.49 × 0.62] + 0.45 × [0.50 × 0.81 + 0.50 × 0.59]⟩ = 0.169 |
| Índice para CT-II = 0.632 |
5. Analysis of Results
The MIVES software is used to conduct the evaluation and consolidate the various criteria, requirements, and indicators into a single index. Table 10 summarizes the “sustainability index” results for each roofing type; as detailed in the previous section, the scores are broken down by indicator, criterion, and requirement.
Table 10.
Indicator scores for calculating the sustainability index.
Following the multi-criteria evaluation, a sustainability hierarchy was established, led by the traditional ichu technique (ITR) with a sustainability index of 0.697. This is followed by clay tiles (CT-II) with 0.632; insulated steel (CGS-II) with 0.602; insulated fiber cement (FC-II) with 0.586; and finally, the polyurethane panel (PIR-SP) with 0.504. Figure 12 shows the evaluation of each technique considering the 11 indicators of the requirements tree.
Figure 12.
Contribution of indicators to the sustainability index. The breakdown of the 11 indicators evaluated for the FC-II, CT-II, CGS-II, PIR-SP, and ITR systems is shown. The visual hierarchy allows for the identification of the predominance of the ITR system (0.697) and the impact distribution of critical variables, such as cost, carbon footprint, and thermal comfort perception.
ITR (Traditional Ichu Roof): This is the most globally sustainable system. Its profile stands out for a minimal environmental footprint, although it presents critical durability (0.012), which represents the major technical weakness in the study due to the organic nature of the material.
CT-II (Clay Tile): Established as the option with the highest cultural acceptance, its value lies in its landscape integration, but it is penalized by low productivity (0.018) compared to panel systems.
CGS-II (Galvanized Steel with an Insulating Layer): A hybrid system that seeks to balance low cost and thermal efficiency. It is highly economically competitive, although its durability (0.034) is moderate compared to more robust industrial panels.
FC-II (Corrugated Fiber Cement with an Insulating Layer): This offers a balanced environmental performance (0.287). However, its social acceptance is the lowest (0.101), suggesting user resistance toward this material despite its technical improvements with insulation.
PIR-SP (Polyurethane Panel): This represents the maximum industrial efficiency with the highest durability (0.084) and speed of assembly. However, its manufacturing process makes it the most polluting system of the group (0.133). Figure 13 shows the evaluation of each technique grouped into economic, environmental, and social dimensions.
Figure 13.
Distribution of global sustainability scores and by requirements. The figure summarizes the evaluation of the 11 indicators grouped into economic, environmental, and social dimensions.
5.1. Dimensional Sustainability Analysis
Economic Dimension: The insulated steel system (CGS-II) leads in this requirement with an accumulated subtotal of 0.275. This advantage comes from its excellent cost per m2 (0.111), significantly surpassing PIR-SP (0.041). In logistics, ITR and CGS-II stand out for their superior local availability (0.106 and 0.085), facilitating implementation in remote areas. Conversely, systems like PIR-SP, although more expensive, compensate for the investment with the highest productivity (0.057) and service life of the group.
Environmental Dimension: The traditional ITR technique dominates this category with a score of 0.315, surpassing all industrial systems; its leadership is indisputable in both carbon footprint (0.122) and water footprint (0.088). In contrast, PIR-SP shows the poorest performance (0.133) due to its polymeric origin. It is notable that insulated FC-II achieves second place environmentally (0.287), demonstrating that modern fiber cement is a competitive ecological alternative to metals.
Social Dimension: Clay tile (CT-II) stands out with the highest score (0.168) due to its excellence in landscape integration (0.048). In terms of habitability, Stipa ichu (ITR) achieves a similar finding by leading in thermal comfort (0.047), surpassing even the polyurethane panel (0.045) and other systems with insulating layers. The main social barrier remains with FC-II, whose low accumulated score (0.101) evidences a lack of citizen identification with this material (0.019).
The Sustainability Paradox—ITR vs. Industrial Systems: Although the ITR technique achieves the highest sustainability index of 0.697, surpassing all contemporary technologies analyzed, this result poses a technical contradiction: while ITR excels in the thermal comfort perception variable (0.047), it exhibits the lowest scores in durability (0.012) and safety perception (0.024). In this research, the ITR roofing system was evaluated in its traditional vernacular version, as typically used in high Andean housing, without chemical treatments or specialized technical reinforcements. Consequently, the organic nature of ITR not only compromises its service life under climatic conditions but also increases its vulnerability to fire. Therefore, it is essential to establish a future line of research focused on the optimization of this traditional technique to enhance its durability through the use of protective layers and fire retardants. Such innovations would allow for the integration of ancestral knowledge with modern standards, transforming ITR into a resilient and competitive solution by innovating its life cycle to ensure long-term durability and safety.
Industrial Efficiency vs. Environmental Load: The polyurethane panel (PIR-SP) represents the opposite extreme to ITR. It is the most technically robust system, with the highest durability (0.084) and productivity (0.057). However, this industrial efficiency translates into a critical environmental load; it is the most polluting system (0.133 environmental index), penalized by its high emissions footprint and energy consumption. The discussion suggests that PIR-SP is ideal for projects where execution speed and service life are the absolute priority, but it is the least viable option under criteria of sustainable architecture and circular economy in rural or protected areas.
5.2. Sensitivity Analysis
To validate the robustness of the results obtained through the MIVES method and evaluate the impact of subjectivity in weight assignment, a sensitivity analysis is performed using a scenario-based weight variation technique, following methodological protocols established in previous research [42,43]. This approach allows for evaluating the stability of the alternative ranking and minimizing the subjectivity inherent in the initial weight assignment. To this end, in addition to the baseline scenario (E1) and a neutral scenario (E2), scenarios with intentional biases (50% predominance) toward the economic (E3), environmental (E4), and social (E5) dimensions are generated. This procedure ensures that the choice of the optimal roofing for the high Andean zone is robust against changes in decision-makers’ priorities, verifying the absence of significant rank reversals.
The sensitivity analysis results (see Table 11) demonstrate high stability in the sustainability ranking. Across the five analyzed scenarios, the traditional ichu thatched roof (ITR) consistently consolidates itself as the alternative with the highest sustainability index, ranging between 0.661 and 0.770. Figure 14 illustrates the performance of the techniques across the 5 scenarios.
Table 11.
Sensitivity analysis comparing five weight scenarios (E1–E5) for the sustainability index of roofing system alternatives in high-altitude regions.
Figure 14.
Sensitivity analysis results for the sustainability index. The graph compares the performance of the five systems (FC-II, CT-II, CGS-II, PIR-SP, and ITR) across five weighting scenarios: baseline (E1), equal weights (E2), economic predominance (E3), environmental predominance (E4), and social predominance (E5).
In the neutral scenario (E2), a slight average variation of −0.44% is observed, suggesting that the equal weighting of dimensions does not alter the ranking of the alternatives. When the economically biased scenario (E3) is applied, the average variation is −1.65%, indicating that systems such as FC-II (−5.17%) are slightly more sensitive. This is attributed to higher installation costs and the need for specialized labor. In the environmentally biased scenario (E4), the highest average increase (4.45%) is observed. This occurs because materials with low embodied energy, such as ITR, perform well due to their organic origin in contrast to the other industrial options. Finally, the socially biased scenario (E5) exhibits a change of −4.12%, showing that metallic systems like CGS-II (−10.16%) are not favored in terms of thermal comfort and user perception. The application of sensitivity analysis yields average variations below 5%, demonstrating the robustness and low volatility of the proposed model for evaluating roofing alternatives. Appendix C and Appendix D show the detailed calculation of the sustainability indicators for each type of roof in scenarios E2, E2, E4, and E5.
6. Conclusions
The multi-criteria evaluation using MIVES established a hierarchy led by the traditional ichu technique (ITR) with a sustainability index of 0.697. It was followed by clay tile (CT-II) with 0.632, insulated steel (CGS-II) with 0.602, insulated fiber cement (FC-II) with 0.586, and finally, the polyurethane panel (PIR-SP) with 0.504.
The traditional ITR technique achieved a score of 0.315 in the environmental dimension, clearly surpassing the other alternatives due to its low carbon footprint (0.122) and low water footprint (0.088). In the social dimension, clay tile (CT-II) was the option with the highest acceptance and cultural integration (0.048). The insulated steel system (CGS-II) presented the best economic performance, with a subtotal of 0.275, due to its low cost (value of 0.111 per m2) and ease of local acquisition. In contrast, the polyurethane panel (PIR-SP) obtained the lowest environmental score (0.133), despite being the system with the highest durability (0.084) and assembly speed (0.057).
The results reveal a limitation in the ITR system: although it is superior globally and environmentally, it is the least durable (0.012) due to its organic nature. This implies that preserving constructions using this traditional technique in the long term requires the development of new maintenance and improvement strategies.
The sensitivity analysis confirmed the stability of the results, maintaining ITR as the optimal option in the five evaluated scenarios (E1–E5). With average variations mostly below 5%, the MIVES model was validated as a reliable and low-volatility tool for complex decision-making in high-altitude contexts.
For future lines of research, a deeper analysis of the life cycle and long-term resistance of these roofing systems under extreme climatic conditions is suggested; these studies are essential to ensure the industrial scalability of the proposed solutions. Incorporating more sustainable roofing techniques into national social housing initiatives would improve energy efficiency, promote the establishment of more inclusive technical regulations, and allow for the revaluation of a traditional construction technique like ITR. To ensure the success of these measures, future research could study financing mechanisms or economic incentives from public or private entities to promote accessible housing suitable for extreme climatic contexts such as the high Andean zone.
Author Contributions
Conceptualization, J.C.C.-G.; G.C.-V.; G.H.A.C. methodology, J.C.C.-G.; G.C.-V.; software J.C.C.-G.; validation, J.C.C.-G.; G.C.-V.; G.H.A.C.; formal analysis, J.C.C.-G.; G.C.-V.; G.H.A.C.; investigation, J.C.C.-G.; G.C.-V.; G.H.A.C.; resources, J.C.C.-G.; G.C.-V.; G.H.A.C.; data curation, J.C.C.-G.; G.C.-V.; G.H.A.C.; writing—original draft preparation, J.C.C.-G.; G.C.-V.; G.H.A.C.; writing—review and editing, J.C.C.-G.; G.C.-V.; G.H.A.C.; visualization, J.C.C.-G.; G.C.-V.; G.H.A.C.; supervision, J.C.C.-G.; project administration, J.C.C.-G.; G.C.-V.; G.H.A.C. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Data Availability Statement
The raw data supporting the conclusions of this article will be made available by the authors on request.
Conflicts of Interest
The authors declare no conflicts of interest.
Appendix A. Value function
Figure A1.
Value function typologies employed in the MIVES model. The characteristic curves (linear, concave, convex, and S-shaped) used to homogenize the physical units of the indicators into a dimensionless value scale (0 to 1) are presented.
Appendix B. Sensitivity Analysis
Figure A2.
Calculation results of the sustainability index for scenario 1 (base case). The ranking of the five evaluated techniques is presented according to the weight distribution originally assigned by the panel of experts. For better identification, indicators are color-coded as follows: blue for economic, green for environmental, and orange for social criteria.
Appendix C. Sensitivity Analysis
Figure A3.
Sensitivity analysis based on five weighting scenarios. Evaluation of model robustness by comparing the resulting sustainability indices for each technique under the different weight distribution hypotheses.
Appendix D. Flow and Traceability of Economic Indicators
Table A1.
Assessment of economic indicators for roofing per square meter (m2).
Appendix E. Flow and Traceability of Environmental Indicators
Table A2.
Integration of the results by alternatives using structured summation as base layer + service components + A4, reporting the total per indicator (GWP, PENRE, and FW).
Table A3.
Summarization of the final values per roof cover for GWP, PENRE, and FW, which are used as input for the environmental branch of the MIVES model.
Appendix F. Flow and Traceability of Social Indicators
Table A4.
Distribution of anonymized surveys in the population center of Imata for social analysis.
Table A5.
Distribution of anonymized surveys in the population center of San Juan de Tarucani for social analysis.
Table A6.
Distribution of anonymized surveys in the population center of Challhuanca for social analysis.
References
- Palomino-Olivera, E.; Ancco-Peralta, M.; Velásquez, V.S.; Mejia-Solis, E.; Rodriguez, E.G. Regulatory Gap Versus Performance Reality: Thermal Assessment of a Social Housing Module in the Peruvian Andes. Buildings 2025, 15, 4401. [Google Scholar] [CrossRef] [Scilit]
- Molina, J.R.; Molina, J.O.; Piñas, M.J.; Horn, M.; Gómez, M. High Andean bioclimatic dwellings in Peru: Climatic conditions, vulnerability of the population and review of academic studies and massification programmes. Renew. Sustain. Energy Rev. 2025, 217, 115690. [Google Scholar] [CrossRef] [Scilit]
- Lindo, M.S.; Blácido, R.D.; Villacorta, O.A. Mejoramiento del confort térmico de vivienda en uso en la ciudad de Huaraz con el aprovechamiento de la energía solar pasiva. Aporte Santiaguino 2016, 9, 37. [Google Scholar] [CrossRef] [Scilit]
- Mejia-Solis, E.; Arias, J.; Palm, B. Simple solutions for improving thermal comfort in huts in the highlands of Peru. Heliyon 2023, 9, e19709. [Google Scholar] [CrossRef] [Scilit]
- Ramos Martínez, E.; Ocupa Florián, D.; Molina Fuertes, J.; Natividad Alvarado, J.; Espinoza Paredes, R.; Prieto Sánchez, R. Acondicionamiento Termico Para Edificaciones Rurales Altoandinas; XX Simposio Peruano De Energia Solar: Tacna, Peru, 2013. [Google Scholar]
- Rojas, M.; Fernandez, L.; Zambrano, L.; Paredes, A. Análisis de la vivienda rural utilizando el confort térmico como medida de habitabilidad. CienciAmérica 2022, 11, 124–138. [Google Scholar] [CrossRef] [Scilit]
- Holguino Huarza, A.; Olivera Marocho, L.; Escobar Copa, K.U. Confort térmico en una habitación de adobe con sistema de almacenamiento de calor en los andes del Perú. Rev. Investig. Altoandinas J. High Andean Res. 2018, 20, 289–300. [Google Scholar] [CrossRef] [Scilit]
- Iruri-Ramos, C.; Domínguez-Gómez, P.; Celis-D’Amico, F. Envelope improvements for thermal behavior of rural houses in the Colca Valley, Perú. Estoa 2023, 12, 113–124. [Google Scholar] [CrossRef] [Scilit]
- Salvador, C.A.; Horn, M.J. Sustainable energization of the high Andean rural region of Peru, based on renewable energy potential. A case study: San Francisco de Raymina, Ayacucho. J. Phys. Conf. Ser. 2021, 1841, 012013. [Google Scholar] [CrossRef] [Scilit]
- Zhang, X.; Lian, Z. The Bioclimatic Design Approach to Plateau Region Buildings: Case of the Lhasa. Procedia Eng. 2015, 121, 2044–2051. [Google Scholar] [CrossRef] [Scilit]
- Quinteiro, P.; Almeida, M.I.; Serra, J.; Arroja, L.; Dias, A.C. Life cycle assessment of ceramic roof tiles: A temporal perspective. J. Clean. Prod. 2022, 363, 132568. [Google Scholar] [CrossRef] [Scilit]
- Ríos-Vizcarra, G.; Calatayud-Rosado, L.E.; Duche-Pérez, A.B. Symbolization and domesticity in the Andean home: A phenomenological approach to dwelling in Coporaque, Peru. Front. Archit. Res. 2025, 14, 94–113. [Google Scholar] [CrossRef] [Scilit]
- Miño-Rodríguez, I.; Naranjo-Mendoza, C.; Korolija, I. Thermal assessment of low-cost rural housing-a case study in the ecuadorian andes. Buildings 2016, 6, 36. [Google Scholar] [CrossRef] [Scilit]
- Vinolas, B.; del Mar Casanovas-Rubio, M.; Pons-Valladares, O.; Josa, I.; Armengou, J.; de la Fuente, A. Sustainability of wall construction techniques for self-built rural housing. A case study from Brazil. Clean. Environ. Syst. 2025, 19, 100348. [Google Scholar] [CrossRef] [Scilit]
- Sarmiento-Pastor, J.; Lira-Chirif, A.; Rondinel-Oviedo, D.R.; Keena, N.; Dyson, A.; Raugei, M.; Acevedo-De-los-Ríos, A. Implications of circular strategies on energy, water, and GHG emissions in informal housing in Lima. Energy Build. 2025, 344, 115949. [Google Scholar] [CrossRef] [Scilit]
- Cárdenas Gómez, J.C. Adobe Reinforced with Reeds as a Thermal-Construction Strategy for Rural High Andean Housing in Peru. In Proceedings of the REHABEND 2024 Congress on Construction Pathology, Rehabilitation Technology and Heritage Management, Gijon, Spain, 7–10 May 2024. [Google Scholar]
- López-Sosa, L.B.; Oseguera-Rivera, A.Y.; Morales-Máximo, M.; Corral-Huacuz, J.C.; Valdespino, J.C.L.; Rodríguez-Torres, G.M.; Rivero, M.; García, C.A.; Orozco, S. Multivariate analysis of materials used in rural housing in Mexico considering sustainability indicators: Towards suitable house construction. Results Eng. 2025, 25, 103744. [Google Scholar] [CrossRef] [Scilit]
- Rojas, M.A.; Altamirano, R. Thermal Comfort in Two Housing Typologies in the Andean Region of Ecuador: Cotopaxi Province. Int. J. Adv. Sci. Eng. Inf. Technol. 2023, 13, 1911–1916. [Google Scholar] [CrossRef] [Scilit]
- Pargana, N.; Pinheiro, M.D.; Silvestre, J.D.; De Brito, J. Comparative environmental life cycle assessment of thermal insulation materials of buildings. Energy Build. 2014, 82, 466–481. [Google Scholar] [CrossRef] [Scilit]
- Khalil, M.; Pons-Valladares, O.; Bosch González, M. A New Decision-Making Tool for Guiding the Sustainability of Adaptive Reuse of Earthen Heritage Complexes in Desert Oases. Sustainability 2025, 17, 10086. [Google Scholar] [CrossRef] [Scilit]
- Botejara-Antúnez, M.; González-Domínguez, J.; García-Sanz-Calcedo, J. Comparative analysis of flat roof systems using life cycle assessment methodology: Application to healthcare buildings. Case Stud. Constr. Mater. 2022, 17, e01212. [Google Scholar] [CrossRef] [Scilit]
- Yussuf, R.O.; Asfour, O.S.; El Fattah, A.A.; Asif, M. A mixed-method comparative analysis of sustainable roofing solutions for thermal and energy efficiency in residential buildings in Saudi Arabia. Results Eng. 2025, 28, 107159. [Google Scholar] [CrossRef] [Scilit]
- Zingre, K.T.; Wan, M.P.; Tong, S.; Li, H.; Chang, V.W.-C.; Wong, S.K.; Toh, W.B.T.; Lee, I.Y.L. Modeling of cool roof heat transfer in tropical climate. Renew. Energy 2015, 75, 210–223. [Google Scholar] [CrossRef] [Scilit]
- Imran, H.M.; Kala, J.; Ng, A.W.M.; Muthukumaran, S. Effectiveness of green and cool roofs in mitigating urban heat island effects during a heatwave event in the city of Melbourne in southeast Australia. J. Clean. Prod. 2018, 197, 393–405. [Google Scholar] [CrossRef] [Scilit]
- Iruri Ramos, C.P.; Domínguez Gómez, P.; Celis D’amico, F. Mejoramiento de la envolvente para el comportamiento térmico de viviendas rurales. Valle del Colca, Perú. Estoa Rev. Fac. Arquit. Urban. Univ. Cuenca 2023, 12, 113–124. [Google Scholar] [CrossRef] [Scilit]
- Wieser, M.; Rodríguez-Larraín, S.; Onnis, S. Estrategias bioclimáticas para clima frío tropical de altura. Validación de prototipo de vivienda. Puno, Perú. Estoa 2021, 10, 9–19. [Google Scholar] [CrossRef] [Scilit]
- Sergio, A. View of Los Cielos de paja y barro aligerado: Respuesta adaptativa al clima extremo en contexto andino. Maskana 2023, 14, 59–73. [Google Scholar] [CrossRef] [Scilit]
- Javier, P.P. Diseño de Vivienda Rural Sostenible de Interes Social con Identidad Cultural en la CP de Yapura-Capachica; Universidad Nacional del Altiplano: Puno, Peru, 2021. [Google Scholar]
- Pons, O.; de la Fuente, A.; Aguado, A. The use of MIVES as a sustainability assessment MCDM method for architecture and civil engineering applications. Sustainability 2016, 8, 460. [Google Scholar] [CrossRef] [Scilit]
- Boix-Cots, D.; Pardo-Bosch, F.; Blanco, A.; Aguado, A.; Pujadas, P. A systematic review on MIVES: A sustainability-oriented multi-criteria decision-making method. Build. Environ. 2022, 223, 109515. [Google Scholar] [CrossRef] [Scilit]
- Pons, O.; Aguado, A. Integrated value model for sustainable assessment applied to technologies used to build schools in Catalonia, Spain. Build. Environ. 2012, 53, 49–58. [Google Scholar] [CrossRef] [Scilit]
- Cárdenas-Gómez, J.C.; Bosch Gonzales, M.; Damiani Lazo, C.A. Evaluation of reinforced adobe techniques for sustainable reconstruction in Andean seismic zones. Sustainability 2021, 13, 4955. [Google Scholar] [CrossRef] [Scilit]
- Rosasco, P.; Perini, K. Selection of (green) roof systems: A sustainability-based multi-criteria analysis. Buildings 2019, 9, 134. [Google Scholar] [CrossRef] [Scilit]
- Zalamea, E.; Alvarado, R.G. Roof characteristics for integrated solar collection in dwellings of Real-Estate developments in Concepción, Chile. Rev. Construcción 2014, 13, 36–44. [Google Scholar] [CrossRef] [Scilit]
- Amin Hosseini, S.M.; De La Fuente, A.; Pons, O. Multi-criteria decision-making method for assessing the sustainability of post-disaster temporary housing units technologies: A case study in Bam, 2003. Sustain. Cities Soc. 2016, 20, 38–51. [Google Scholar] [CrossRef] [Scilit]
- Cárdenas-Gómez, J.C.; Chuquitaype, M.A.M. Sumaq Wasi, Analysis of the experience in bioclimatic social housing in Andean areas of southern Peru. In ZEMCH 2023—10o Zero Energy Mass Custom Home International Conference; UCSP: Arequipa, Peru, 2023. [Google Scholar]
- Cárdenas-Gómez, J.C.; Bosch Gonzalez, M.; Damiani Lazo, C.A. Comparative study of techniques in reinforced adobe for the sustainable reconstruction of the Colca Valley after the 2016 earthquake. In Proceedings of the 9th REHABEND Congress, Granada, Spain, 13–16 September 2022. [Google Scholar]
- Josa, I.; Pons, O.; de la Fuente, A.; Aguado, A. Multi-criteria decision-making model to assess the sustainability of girders and trusses: Case study for roofs of sports halls. J. Clean. Prod. 2020, 249, 119312. [Google Scholar] [CrossRef] [Scilit]
- Josa, I.; de la Fuente, A.; Casanovas-Rubio, M.D.M.; Armengou, J.; Aguado, A. Sustainability-oriented model to decide on concrete pipeline reinforcement. Sustainability 2021, 13, 3026. [Google Scholar] [CrossRef] [Scilit]
- Moreno, W.G.C.; Alegre, I.; Armengou-Orús, J.; Aguado, A. Self-construction in informal settlements: A multiple-criteria decision-making method for assessing sustainability of floor slabs in Bucaramanga, Colombia. J. Hous. Built Environ. 2018, 34, 195–217. [Google Scholar] [CrossRef] [Scilit]
- Pons, O.; De La Fuente, A. Integrated sustainability assessment method applied to structural concrete columns. Constr. Build. Mater. 2013, 49, 882–893. [Google Scholar] [CrossRef] [Scilit]
- Pons, O.; Habibi, S.; Peña, D. Sustainability assessment of household waste based solar control devices for workshops in primary schools. Sustainability 2018, 10, 4071. [Google Scholar] [CrossRef] [Scilit]
- De La Fuente, A.; Pons, O.; Josa, A.; Aguado, A. Multi-criteria decision making in the sustainability assessment of sewerage pipe systems. J. Clean. Prod. 2016, 112, 4762–4770. [Google Scholar] [CrossRef] [Scilit]
- Viñolas, B.; Cortés, F.; Marques, A.; Josa, A.; Aguado, A. MIVES: Modelo integrado de valor para evaluaciones de sostenibilidad-ICSMM 2009. In Proceedings of the II Congrés Internacional de Mesura i Modelització de la Sostenibilitat, Barcelona, Spain, 5–6 November 2009; Available online: https://hdl.handle.net/2117/9704 (accessed on 13 December 2025).
- INEI Instituto de Estadistica e Informática. Directorio Nacional de Centros Poblados Censos Nacionales 2017: XII de Población, VII de Vivienda y III de Comunidades Indígenas; INEI Instituto de Estadistica e Informática: Lima, Peru, 2018. [Google Scholar]
- Senamhi. Boletin Climatico Regional Octubre 2024. Arequipa, Peru, 2024. Available online: http://www.senamhi.gob.pe (accessed on 13 December 2025).
- Senamhi. Monthly Bulletin: UV-B Radiation Monitoring in Cities of the Country, January 2020. Available online: https://www.senamhi.gob.pe/load/file/03202SENA-52.pdf (accessed on 1 October 2025).
- CENEPRED. Escenarios de Riesgo por Heladas y Friajes en el Marco del Plan Multisectorial Multianual 2025–2027; Centro Nacional de Estimación, Prevención y Reducción del Riesgo de Desastres: Lima, Peru, 2024. [Google Scholar]
- Molina, J.O.; Lefebvre, G.; Horn, M.; Gómez, M.M. Design of an experimental bioclimatic module obtained from the analysis of thermal simulations for the community of Imata (4519 m A.S.L.), located in Arequipa, Perú. Inf. Tecnol. 2020, 31. [Google Scholar] [CrossRef] [Scilit]
- Gonzales, M.C.P.; Molina-Fuertes, J.O.; Horn-Mutschler, M.J.; Gómez-León, M.M. Evaluación térmica de modificaciones en las envolventes de módulos experimentales ubicados en el centro poblado de Imata (4519 msnm), Arequipa. TECNIA 2021, 31, 18–27. [Google Scholar] [CrossRef] [Scilit]
- Dégrange, S.R.L.; Onnis, S.; Wieser, M.; Neumann, J.V. Vivienda alto andina con confort térmico y sismo resistencia. Minist. Ambiente 2019, 1–6. [Google Scholar]
- MIDIS–FONCODES. Mi Abrigo—Casitas calientes y seguras ante las heladas: Serie de Publicaciones 6, Gestión de Proyectos de Inversión Social bajo la modalidad de Núcleo Ejecutor, Peru, 2020. Available online: https://www.calameo.com/books/001548636438d5d567fac (accessed on 4 October 2025).
- Simon, S. Whole Life Carbon Assessment for the Built Environment; RICS: London, UK, 2024; Available online: http://www.rics.org (accessed on 8 October 2025).
- UNE-EN 15804:2012+A2; Sostenibilidad en la Construcción Declaraciones Ambientales de Producto Reglas de Categoría de Producto Básicas Para Productos de Construcción. Asociación Española de Normalización: Madrid, Spain, 2020.
- Söner, J.G.A.; Linneryd, A.B. Environmental Product Declaration. 2023. Available online: http://www.jga.se (accessed on 1 October 2025).
- Trapezoidal Corrugated Steel Sheet for Construction Industry. 2023. Available online: http://www.environdec.com (accessed on 7 October 2025).
- Würth Group/Adolf Würth GmbH & Co. KG. Environmental Product Declaration as per ISO 14025 and EN 15804+A2-Steel Screws; Declaration Number EPD-AWU-20230570-CBA1-EN; Institut Bauen und Umwelt e.V. (IBU): Berlin, Germany, 2024; Available online: https://www.environdec.com/library/epd7424 (accessed on 9 October 2025).
- Federal Public Service of Health, Food Chain Safety and Environment, Program Operator. SVK Fibre Cement Corrugated Sheets; B-EPD Environmental Product Declaration: Brussels, Belgium, 2023; Available online: https://svk.global/uploads/files/Downloads/b-epd_21_0073_006_00_01_en_svk_flat_signed.pdf (accessed on 16 September 2025).
- ISO 10456:2007; Building Materials and Products—Hygrothermal Properties—Tabulated Design Values and Procedures for Determining Declared and Design Thermal Values. International Organization for Standardization: Geneva, Switzerland, 2007.
- Johansson, J.; Programme, E. EPD Profile EPD Owner BMI Sverige AB. Available online: http://www.bmisverige.se (accessed on 4 October 2025).
- The International EPD® System, EPD International AB. General Information Programme Information Programme: Accountabilities for PCR, LCA and Independent, Third-Party Verification Product Category Rules (PCR). Europe. 2024. Available online: https://www.environdec.com (accessed on 4 September 2025).
- DuPont de Nemours DuPont™ Tyvek® 2524B. Environmental Product Declaration (EPD) as per ISO 14025 and EN 15804+A2; Declaration Number EPD-DUP-20210187-IBC1-EN; Institut Bauen und Umwelt e.V. (IBU): Berlin, Germany, 2021; Available online: https://www.dupont.co.uk/content/dam/dupont/amer/us/en/performance-building-solutions/public/documents/en/EPD-Tyvek-2524B.pdf (accessed on 15 October 2025).
- IBU. DuPont TM Tyvek® Airguard® Smart 2009B. Available online: https://epd-online.com (accessed on 15 October 2025).
- ISO 14044:2006; Environmental Management-Life Cycle Assessment-Requirements and Guidelines Management Environnemental-Analyse du Cycle de Vie-Exigences et Lignes Directrices iTeh STANDARD PREVIEW. ISO: Geneva, Switzerland, 2006.
- ISO 14040:2006; Environmental Management—Life Cycle Assessment—Principles and Framework. ISO: Geneva, Switzerland, 2006. Available online: https://www.iso.org/standard/37456.html (accessed on 9 October 2025).
- Hinojosa Gaspar, A.N. Geo-Vivienda Archipiélago: Confort Térmico en la Vivienda Altoandina Mediante red Geotermal—Huayllay, Pasco; PUCP: Lima, Peru, 2023. [Google Scholar]
- The International EPD. Construction Products (EPD International); EPD: Stockholm, Sweden, 2019. [Google Scholar]
- Camara Peruana de la Construcción. Manual de Precios Unitarios CAPECO; Camara Peruana de la Construcción: Lima, Peru, 2025. [Google Scholar]
- Revista Costos. Suplemento Técnico Revista Costos Noviembre 2025. Lima, 2025. Available online: https://t.me/Ingenieriacivilperu (accessed on 2 October 2025).
- Nolan, D.; O’Reilly, B. Thatch a Guide to the Repair of Thatched Roofs; Advice Series; The Stationery Office: Dublin, Ireland, 2015. [Google Scholar]
- Zhang, X.G.; Alhassan, S.; Goodwin, F.E. Predicting Life of Galvanised Steel on Internet. In Proceedings of the CORROSION 2004, New Orleans, LA, USA, 28 March–1 April 2004. [Google Scholar]
- Stoklund Larsen, E. Service Life Prediction and Fibre Reinforced Cementitious Composites; Aalborg University: Alemania, Germany, 1992. [Google Scholar]
- Institut Bauen und Umwelt e.V. (IBU). Double Skin Steel Faced Sandwich Panels with a Core Made of Polyurethane. 2024. Available online: https://www.oekobaudat.de/OEKOBAU.DAT/datasetdetail/process.xhtml?uuid=e8dc4ff1-cb8f-467f-bedc-f8c8420bd552&version=00.02.000 (accessed on 4 October 2025).
- Silva, A.; de Brito, J. Service life of building envelopes: A critical literature review. J. Build. Eng. 2021, 44, 102646. [Google Scholar] [CrossRef] [Scilit]
- NedZink, B.V. Umwelt Produkt Deklaration; Environmental Product Declaration: Berlin, Germany, 2020; Available online: https://epd-online.com (accessed on 15 September 2025).
- Strazza, C.; Del Borghi, A.; Magrassi, F.; Gallo, M. Using environmental product declaration as source of data for life cycle assessment: A case study. J. Clean. Prod. 2016, 112, 333–342. [Google Scholar] [CrossRef] [Scilit]
- Del Rosario, P.; Palumbo, E.; Traverso, M. Environmental product declarations as data source for the environmental assessment of buildings in the context of level(S) and dgnb: How feasible is their adoption? Sustainability 2021, 13, 6143. [Google Scholar] [CrossRef] [Scilit]
- The International EPD® System EPD International AB. Environmental Product Declaration TW1, TW1-E, Climowool Board 037. Europe. 2025. Available online: https://www.environdec.com (accessed on 11 September 2025).
- European Commission; Joint Research Centre; Institute for Environment and Sustainability (Eds.) ILCD Handbook General Guide for LCA—Detailed Guidance, 1st ed.; Publications Office of the European Union: Ispra, Italy, 2010. [Google Scholar]
- Dodd, N.; Cordella, M.; Traverso, M.; Donatello, S. Level(s)—A Common EU Framework of Core Sustainability Indicators for Office and Residential Buildings Parts 1 and 2: Introduction to Level(s) and How It Works (Beta v1.0). 2017. Available online: https://publications.jrc.ec.europa.eu/repository/handle/JRC109285 (accessed on 9 September 2025).
- ISO 6946:2017; Building Components and Building Elements—Thermal Resistance and Thermal Transmittance—Calculation Methods [Composants et Parois de Bâtiments—Résistance Thermique et Coefficient de Transmission Thermique—Méthodes de Calcul]. ISO: Geneva, Switzerland, 2017.
- ISO 13788:2012; Hygrothermal Performance of Building Components and Building Elements—Internal Surface Temperature to Avoid Critical Surface Humidity and Interstitial Condensation—Calculation Methods. ISO: Geneva, Switzerland, 2012.
- Carlo, F.; Christensen, A.S. Environmental Product Declaration: Thatched Roof. EPD Danmark. 2024. Available online: https://www.epddanmark.dk/uk/epd-database/carlo-f-christensen-a-s/thatched-roof (accessed on 16 October 2025).
- The International EPD. Environmental Product Declaration Straw as Insulation Material-UK Up-Straw-Straw Building UK (SBUK). Suffolk. 2021. Available online: http://www.environdec.com (accessed on 10 October 2025).
- Alarcon, B.; Aguado, A.; Manga, R.; Josa, A. A value function for assessing sustainability: Application to industrial buildings. Sustainability 2011, 3, 35–50. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.