Abstract
Traditional architecture in hot–dry regions embodies accumulated climate-responsive design knowledge that can provide useful principles for contemporary passive building design. Among the characteristic spatial elements of traditional Diyarbakır courtyard houses, the eyvan functions as a semi-open transitional space that provides shading and contributes to the thermal moderation of adjacent indoor spaces. However, in contrast to the formal and typological analyses dominant in the literature, quantitative field evidence concerning the influence of eyvan configuration on indoor thermal performance remains limited. This study investigates the thermal performance associated with three eyvan configurations, single-arched, double-arched, and triple-arched, through temperature and relative humidity measurements conducted at 30-min intervals in three traditional Diyarbakır courtyard houses during June–August. The results show that, during peak hours, the indoor temperatures of spaces adjacent to the investigated eyvans were considerably lower than the corresponding outdoor temperatures. Cooling Degree-Hour (CDH) analysis indicated lower summer temperature exceedance in the investigated building with the largest eyvan configuration. However, these differences reflect the combined thermal characteristics of the three buildings rather than the isolated effect of eyvan volume. The observations showed a consistent case-specific trend in which larger eyvan-to-room volume ratios were associated with lower indoor temperatures. These findings provide quantitative field evidence of the thermal benefits associated with a traditional climate-responsive spatial strategy and indicate that principles derived from eyvan design may inform passive cooling approaches in contemporary buildings in hot–dry climates.
1. Introduction
It is widely acknowledged that approximately one-third of global energy consumption is attributed to construction activities [1]. The amount of energy consumed varies depending not only on the climatic conditions of the region where buildings are located, but also on the quantitative and qualitative characteristics of the building and its performance in response to the physical environment [2]. In most countries, people spend approximately 90% of their time indoors, a significant portion of which is spent in residential buildings [3]. However, the majority of newly constructed housing today is designed without adequately considering the physical environmental conditions of the region, leading to climatic and environmental problems associated with excessive energy consumption [4].
Designs that do not take physical environmental conditions into account necessitate the use of mechanical systems for heating, cooling, and ventilation [5]. Achieving indoor comfort under optimal conditions requires substantial energy consumption [6]. Since mechanical conditioning systems rely on fossil fuels and electricity, natural resources are rapidly depleted, and harmful emissions are released into the atmosphere as a result of their use [7]. The building sector accounts for approximately 40% of global final energy consumption and nearly one-third of energy-related greenhouse gas emissions [8]. In the 21st century, global energy consumption has been increasing at an average annual rate of 2%, with 80% of this increase driven by fossil fuels [9]. When design decisions made during the building design phase are not compatible with climatic conditions, one of the key factors affecting thermal performance, users are compelled to rely on systems that actively consume energy.
Furthermore, in regions experiencing infrastructural uncertainties, energy-supply disruptions, or energy poverty, reliance on active heating and cooling systems may present additional challenges. In such circumstances, alternative or dual-fuel heating arrangements may be adopted, potentially introducing concerns regarding energy efficiency, occupant safety, and indoor air quality [10]. These considerations further highlight the importance of climate-responsive passive design strategies in reducing dependence on active building-conditioning systems.
This necessitates the adoption of planning decisions during the design phase that enable effective control of energy consumption. Therefore, the most effective approach to reducing energy consumption is the implementation of passive strategies that take environmental parameters into account at the early stages of design. A strong relationship exists between thermal performance, which is the most critical parameter affecting indoor thermal comfort during building operation, and spatial planning characteristics. Passive strategies, which are among the key approaches to improving energy performance in the building sector, reduce energy consumption by both enhancing the use of natural heating, cooling, and lighting potential and limiting energy losses through the building envelope, in line with the nearly zero-energy building approach [11,12]. In hot–dry climate regions, passive design strategies aimed at preventing overheating and reducing cooling energy demand, through solar control, natural ventilation, and the effective use of thermal mass, can only be achieved through the proper evaluation of local climatic conditions, building planning, and the technical properties of construction materials [13] (Figure 1).
Figure 1.
Overview of passive design principles for reducing energy demand (compiled by the authors based on [11,13]).
Traditional houses, as historical artifacts, not only reflect the social, economic, and cultural characteristics of the period in which they were built, but also incorporate various passive design strategies adapted to the climatic conditions of their region [14]. One of the most important passive design strategies in buildings is the effective use of solar radiation. Particularly in hot regions, shading plays a crucial role in reducing cooling loads, which account for a significant portion of total energy consumption. In this context, traditional buildings in hot–dry climates offer optimal examples of shading strategies. In the spatial organization of traditional houses in these regions, climate-responsive design strategies such as open and semi-open spaces are prominent. The courtyard, as an open space, and the eyvan, a semi-open space enclosed on three sides and serving as a transitional element between rooms, constitute the fundamental components of spatial organization [15].
The use of courtyards and eyvans in different orientations, sizes, and forms can contribute to the passive moderation of indoor thermal conditions during hot and cold periods, potentially reducing the dependence on active heating and cooling systems [16]. The incorporation of these design strategies into contemporary living environments can play a significant role in maintaining fossil fuel consumption at an optimal level [17].
Traditional houses, with their accumulated architectural knowledge, can guide newly constructed housing in terms of sustainability and climate-responsive design parameters. Spatial elements that developed in response to local environmental conditions can be regarded as regionally adapted passive design strategies whose performance can be examined using contemporary building-physics methods. From this perspective, traditional architecture provides not only cultural and formal references, but also practical examples of how spatial planning, shading, thermal mass, and natural air movement can contribute to indoor thermal regulation. In recent decades, these passive strategies have therefore become an important focus of research aimed at minimizing building energy demand, controlling fossil fuel consumption, and mitigating greenhouse gas emissions. Numerous studies have evaluated the effects of courtyards on thermal and visual comfort across different geographical contexts, particularly in hot–dry climate regions, through quantitative and experimental methods. However, in-situ studies that quantitatively address the contribution of eyvans to thermal performance remain limited in the literature.
Eskandari et al. investigated the effect of eyvans on energy consumption across four different climate zones and orientations through both numerical and experimental methods, and proposed optimum eyvan design parameters in terms of depth and form to reduce thermal loads under varying climatic conditions [16]. In their study, Ayçam et al. simulated courtyard types, settlement patterns, and urban fabric by examining traditional architectural parameters of historic Diyarbakır houses in a hot–dry climate. The analyses indicated that shading plays a significant role in energy-efficient building design in such climates, reducing energy consumption and improving thermal performance [18,19]. Guedouh et al. conducted in-situ measurements in courtyard buildings in hot–dry regions to investigate the relationship between thermal conditions and daylighting performance in courtyard spaces. The study derived design implications based on morphological analysis [20]. Al-Hafith et al. compared simulation results of a representative courtyard building in a desert climate with field thermal measurements obtained from a previous study. The study concluded that courtyard design is an energy-efficient and climate-responsive design strategy for hot regions [21]. Diz-Mellado et al. investigated the capacity of courtyards to create thermally comfortable spaces in hot climates through shading effects. The study emphasized the thermal potential of courtyards and their usability in hot environments, and suggested that they can be incorporated into building analysis as thermally comfortable spatial components [22]. Baboli et al. investigated the adaptation potential of thirty-four courtyard houses to users’ comfort requirements and demonstrated that courtyard design also yields effective performance in warm-humid climate regions [14]. Almumar et al. developed an orientation strategy in traditional courtyard houses in Iraq to allow main façades to receive solar gain in winter and to block solar radiation in summer. The study showed that this design strategy contributes to the natural heating and cooling of the house [23]. De la Flor et al. evaluated the impact of courtyards on reducing building energy consumption, particularly for cooling demand. The study found that courtyards reduce cooling demand in the surrounding spaces [24]. Abuhussain et al. showed that courtyard-focused passive design strategies reduced total energy consumption by 32.80% compared to the baseline case [25]. Helali examined courtyards as a climatic element in traditional Iranian houses, evaluating natural cooling, cross-ventilation, solar and wind use, courtyard orientation and energy consumption, and the role of water and vegetation in courtyards in terms of sustainability [26]. Ibrahim et al. optimized courtyard parameters such as building height, orientation, and voids for the hot–dry climate of Cairo, Egypt [27].
Courtyard and eyvan elements are climate-responsive components of traditional architecture in hot–dry regions. While courtyards influence the microclimate as fully open spaces, eyvans function as semi-open buffer zones directly integrated with indoor living spaces. Therefore, eyvans are distinctive spatial elements that can affect indoor thermal conditions through shading, reduced solar exposure, and interaction with outdoor air movement. Numerous studies have investigated courtyard design in hot climates to explore the energy-efficient potential of traditional houses and optimize them for thermal comfort; however, quantitative field studies examining the thermal performance associated specifically with different eyvan configurations remain limited. Based on this gap, the present study investigates three traditional Diyarbakır courtyard houses with single-, double-, and triple-arched eyvans using simultaneous temperature and relative humidity measurements. The study further evaluates peak-hour temperature differences, Cooling Degree-Hours, and the relationship between the eyvan-to-room volume ratio and indoor temperature. The primary objective of this study is to empirically compare the indoor thermal conditions associated with single-, double-, and triple-arched eyvan configurations in three traditional Diyarbakır courtyard houses and to explore the potential relevance of these case-specific findings for contemporary passive building design in hot–dry climates.
2. General Characteristics of the Study Area
2.1. Physical and Geographical Characteristics of the Study Area
The Suriçi district of Diyarbakır Province, located in the Dicle subregion of Southeastern Anatolia, is situated on a wide basalt plain at an elevation of approximately 650 m above sea level and about 100 m above the Tigris Valley (Figure 2). The topography, characterized by steep slopes to the east and southeast and gentle slopes to the north and west, has been a determining factor in the form of the city walls surrounding the historic city center [28,29]. The Suriçi district of Diyarbakır, covering an area of 158 ha, was registered as an urban conservation site by the Diyarbakır Conservation Board in 1988, and the Conservation-Oriented Development Plan for Suriçi was approved in 1990 [30]. The historic Suriçi district, enclosed by approximately 5200 m-long Diyarbakır city walls, contains traditional courtyard houses that constitute cultural and architectural heritage [31].
Figure 2.
Satellite image and elevation profile of the Suriçi district, Diyarbakır [32]. The red line indicates the transect along which the elevation profile was obtained (Map data: Google Earth Pro, imagery Maxar Technologies).
The Southeastern Anatolia Region has high average temperature values in terms of temperature distribution in Turkey. Diyarbakır, located in this region and characterized by a hot–dry climate, experiences hot and dry summers and cold winters. Low relative humidity levels in the region result in arid conditions [33]. When the 2022 summer maximum temperature map of Turkey is examined, it is observed that all provinces in the Southeastern Anatolia Region, including Diyarbakır, fall within the scale corresponding to very-high-temperature values during the summer period (Figure 3) [34].
Figure 3.
Choropleth map of Turkey showing 2022 summer maximum temperatures. Darker areas represent hotter regions, primarily in the southern interior, while cooler areas appear in the northeast near the Black Sea [34] (labels translated by the authors).
According to climate data between 1929 and 2021, the highest monthly mean temperature is 31.0 °C in July. The lowest monthly mean temperature is 1.8 °C in January. The annual mean temperature is 15.9 °C. The highest monthly total precipitation occurs in December with 72.2 mm, while the lowest occurs in August with 1.0 mm. The annual total precipitation is 494.9 mm (Figure 4) [34].
Figure 4.
Climatic diagram of Diyarbakır (1929–2021) (plotted by the authors using official statistical data from the Turkish State Meteorological Service [34]).
2.2. Use of Eyvan and Its Climatic Role in the Suriçi District
In hot–dry climates, another element that emerges in response to environmental conditions is the eyvan unit, which is enclosed on three sides and covered on top, opening onto the courtyard, and is widely used in courtyard houses in Diyarbakır [35]. The eyvan, believed to originate from Mesopotamian civilizations, takes its most characteristic form in eastern Anatolian examples. This is because, in this region, the eyvan is directly connected to the courtyard and is used for cooling purposes [36,37]. The porous basalt stone used in the floor coverings of eyvan units has a high water retention capacity. During the hot summer period, basalt floors are wetted, and the evaporation of the absorbed water provides a cooling effect. In addition to flooring, basalt stone is also used in wall construction; its high thermal mass creates a time lag, slowing the transfer of high outdoor temperatures into the interior. During colder periods, it delays the decrease in indoor temperature. As a climate adaptation strategy in the hot–dry region, it has been observed that north-facing eyvans are more common than those oriented in other directions [38] (Figure 5).
Figure 5.
Orientation distribution of eyvans in the Suriçi District (plotted by the authors based on numerical data reported by Tuncer [38]).
In traditional courtyard houses of Diyarbakır, building masses are positioned with consideration of seasonal variations. The mass located on the south and oriented toward the north forms the summer spaces. This north-facing orientation provides advantages in terms of reduced solar radiation and access to cooler air flows, especially during the hottest hours of the day in hot–dry climates. Eyvans in the summer block are designed with greater ceiling heights and wider arch openings, aiming to increase the air volume circulating within the eyvan and enhance its cooling effect during hot periods. In addition, providing access to adjacent rooms through the eyvan helps protect these spaces from direct solar radiation and hot air currents. The mass, typically located on the north and oriented toward the south, constitutes the winter spaces. With its south-facing façade, the winter block is designed to benefit from solar radiation (Figure 6a,b).
Figure 6.
(a). Positioning of summer and winter blocks in relation to the courtyard; (b). View of the summer block from the courtyard (schematic diagram and photograph by the authors [15]).
Eyvans, used as a climate-responsive design strategy to mitigate the adverse effects of hot–dry climate conditions, also function as transitional spaces connecting the courtyard to rooms and facilitating circulation between rooms. In this context, various eyvan–room configurations can be observed in the spatial organization. Traditional Diyarbakır courtyard houses exhibit different typologies of eyvan–room relationships (Table 1). Moving from the basic room–eyvan arrangement to more complex eyvan-centered layouts, the eyvan assumes either a connecting role or, in some cases, functions as a central core. These configurations enable users to establish a direct connection with the courtyard while maintaining privacy. Arrangements such as the inverted T or entrance eyvan help promote cross-ventilation in response to hot–dry climate conditions. As a semi-open space enclosed on three sides, the eyvan facilitates cooling through natural air movement by utilizing pressure differences with the open courtyard. The eyvan–room relationships in Diyarbakır courtyard houses represent the outcome of a strategic spatial organization shaped by both user needs and climatic factors.
Table 1.
Room–eyvan connections in traditional courtyard houses of Diyarbakır (typological classification based on [38,39]; schematic diagrams and photographs by the authors [15]).
The eyvan unit in houses appears in different orientations, floors, and sizes. In the houses of the Suriçi district, three types of eyvans are identified based on the number of arches: single-arch (1A), double-arch (2A), and triple-arch (3A) (Table 2). Eyvans located on the southern wing and oriented toward the north are not exposed to direct solar radiation and are therefore used for daily activities during the hot period of the year; accordingly, they are constructed in larger dimensions. It is observed that the type, size, orientation, and floor level of eyvans in the Suriçi district are shaped by climatic conditions. In addition to achieving optimal adaptation to the hot–dry climate, eyvans are also designed to function as connecting units within the spatial organization.
Table 2.
Physical dimensions of eyvans in the selected case study mansions.
3. Methodology
3.1. Case Study
Within the scope of the study, Cemil Paşa Mansion, İskender Paşa Mansion, and Zerzevan Mansion were selected among traditional courtyard houses with eyvans located in the historic district, based on the criteria of eyvan orientation, eyvan volume (number of arches), and floor level (Figure 7). Cemil Paşa Mansion has a single-arch eyvan, Zerzevan Mansion has a double-arch eyvan, and İskender Paşa Mansion has a triple-arch eyvan. Cemil Paşa Mansion was originally designed as a mansion in the 17th century and was refunctioned as a City Museum in 2015 after undergoing survey, restitution, and restoration processes in 2013. Although the construction date of Zerzevan Mansion is unknown, it was designed as a residence and is currently used as a cafeteria. İskender Paşa Mansion was designed as a mansion in the 16th century [38]. Restored between 2009 and 2011, it was refunctioned as a cafeteria in 2015.
Figure 7.
Locations of the selected mansions in the study area [32] (Map data: Google Earth Pro, imagery Maxar Technologies).
Cemil Paşa Mansion, which is the subject of the study, has a single-arch eyvan, Zerzevan Mansion has a double-arch eyvan, and İskender Paşa Mansion has a triple-arch eyvan (Table 3). In Cemil Paşa Mansion, the room adjacent to the eyvan where temperature measurements were taken has dimensions of 4.50 m in length, 3.25 m in width, and 3.40 m in ceiling height, and includes a total of three windows: one facing the courtyard and two facing the eyvan. In Zerzevan Mansion, the room adjacent to the eyvan where temperature measurements were taken has dimensions of 6.00 m in length, 3.50 m in width, and 4.00 m in ceiling height, and includes a total of eight windows, four facing the courtyard and four clerestory windows. In İskender Paşa Mansion, the room adjacent to the eyvan where temperature measurements were taken has dimensions of 4.70 m in length, 6.60 m in width, and 5.30 m in ceiling height, and includes three windows facing the courtyard and three clerestory windows. In all three mansions, the measured spaces are covered with wooden beams along the short-span direction.
Table 3.
Schematic diagram and façade views of the studied buildings.
Within the scope of this study, the selected eyvans were classified according to the number of arches, representing single-arched (1A), double-arched (2A), and triple-arched (3A) configurations. To improve comparability, the three investigated eyvans were selected based on common architectural characteristics, particularly their north-facing orientation, ground-floor location, and the presence of adjacent indoor spaces suitable for temperature and relative humidity measurements (Table 4). However, as the investigated buildings are existing historic structures rather than experimentally controlled cases, several potentially influential architectural characteristics could not be standardized. These include the dimensions and ceiling heights of the adjacent rooms, the number and arrangement of windows, façade transparency, wall thickness, thermal mass, and other building-envelope characteristics. In addition, differences in the historical and functional contexts of the buildings may influence their indoor thermal conditions. Consequently, these factors should be regarded as potential confounding variables, and the measured temperature differences cannot be attributed exclusively to eyvan configuration or volume. The investigated cases should therefore be considered comparative field observations rather than geometrically equivalent experimental configurations.
Table 4.
Eyvan configurations and common selection criteria of the investigated buildings.
In addition to north orientation and ground-floor location, and based on the presence of adjacent spaces where thermal performance was measured, Cemil Paşa Mansion, Zerzevan Mansion, and İskender Paşa Mansion, which represent traditional courtyard houses in Diyarbakır, were selected for analysis.
3.2. Measurement Setup
Between 1 June 2022 and 31 August 2022, temperature and humidity measurements were conducted simultaneously in the rooms adjacent to the eyvans in the three selected mansions. Temperature and humidity measurements were carried out using an Extech RHT10 Humidity and Temperature USB Datalogger. According to the manufacturer’s specifications, the dataloggers have a temperature measurement range of −40 to 70 °C with a basic accuracy of ±1.0 °C (within the −10 to 40 °C range) and a resolution of 0.1 °C. The relative humidity measurement range is 0 to 100% with a basic accuracy of ±3% and a resolution of 0.1%. The devices were positioned at approximately 2 m above the floor level (Figure 8).
Figure 8.
(a). Extech RHT10 humidity and temperature USB datalogger (b). 1A (single-arch) measurement point (c). 2A (double-arch) measurement point (d). 3A (triple-arch) measurement point. In (b–d), red circles show where the datalogger was placed.
The measurement interval of the device was set to 30 min. During the measurement period, no mechanical conditioning systems were used in any of the three mansions. Reports of temperature and relative humidity data obtained from the three mansions were prepared using the RHT10-SW software v. 5.8.3 compatible with the device. The reports prepared for each mansion were processed into graphs on a weekly basis and evaluated accordingly. The performance differences among the mansions were analyzed by comparatively plotting temperature and humidity data from the three buildings. In addition, the effect of the number of arches on thermal performance during the hot period was examined by comparing the measured indoor temperatures of the three mansions with outdoor temperatures on the same dates. Furthermore, the eyvan-to-room volume ratio was calculated. The results obtained for each mansion were proportioned and analyzed to determine whether there was a relationship with indoor temperatures. Conclusions and recommendations were developed through the interpretation of the comparative graphs.
3.3. Data Processing
The indoor temperature and relative humidity measurements recorded at 30-min intervals between 1 June and 31 August 2022 were processed using Microsoft Excel. The original measurements were first examined for completeness and consistency, including the identification of potentially missing or anomalous observations. Subsequently, the recorded values were aggregated into hourly averages to characterize the thermal conditions within the three investigated buildings.
For the comparative analysis of thermal conditions, the hourly data were further aggregated into weekly summaries. These summaries were used to generate the weekly temperature and relative humidity profiles presented in the corresponding figures. The comparisons among the single-arched (1A), double-arched (2A), and triple-arched (3A) configurations were based on 13 weekly observations covering the summer monitoring period. Outdoor temperature and relative humidity data for Diyarbakır were obtained from The Weather Company (IBM) and aligned with the corresponding indoor measurement periods to facilitate comparisons between indoor and outdoor conditions.
The temperature differences between the investigated cases were calculated using the paired weekly average indoor temperatures. For each of the 13 weekly observations, the temperature difference between two cases was determined by subtracting the average temperature of the second case from that of the first. The minimum, maximum, and average of these paired differences were subsequently calculated and are presented in Table 5. In contrast, the Cooling Degree-Hours (CDH) analysis was based on hourly average indoor temperatures to quantify cumulative temperature exceedance above the selected reference threshold. This processing approach enabled the evaluation of both weekly thermal variations and cumulative temperature exceedance while maintaining a consistent basis for comparing the three investigated buildings.
Table 5.
Minimum, maximum, and average differences between the weekly average indoor temperatures of the single-arched (1A), double-arched (2A), and triple-arched (3A) cases.
To quantify cumulative indoor air-temperature exceedance during the summer measurement period, Cooling Degree-Hours (CDH) were calculated using a reference temperature of 26 °C. This reference temperature has been employed in previous degree-hour analyses [40] and was adopted in the present study to provide a consistent basis for comparing the three investigated buildings. However, the selected threshold does not represent a comprehensive thermal comfort criterion, and the calculated CDH values should not be interpreted as direct measures of cooling-energy consumption.
The original temperature measurements, recorded at 30-min intervals, were first aggregated into hourly average values. For each investigated building, CDH was calculated by summing the positive differences between the hourly indoor air temperatures and the selected reference temperature over the measurement period, according to the following equation:
where is the hourly average indoor air temperature (°C) at time interval i, Tbase is the selected reference temperature (26 °C), Δt is the time interval (1 h), and N is the total number of hourly observations included in the calculation. Only positive temperature differences contribute to the summation; hours during which the indoor temperature is equal to or below 26 °C contribute zero. The resulting CDH values are expressed in °C·h and represent cumulative indoor air-temperature exceedance above the selected reference threshold.
3.4. Verification and Limitations
To ensure data reliability, measurements in all three mansions were conducted simultaneously using identical devices (Extech RHT10 Humidity and Temperature USB Datalogger). Prior to installation, the devices were calibrated in accordance with the manufacturer’s instructions. The sensors were positioned at approximately 2.0 m above the floor level to enable consistent long-term monitoring while minimizing interference with activities within the investigated historic buildings. Similar measurement arrangements have been reported in previous studies of traditional and historic buildings. Khei et al. [41] employed elevated sensor positions of 2.0–3.0 m in occupied vernacular buildings to prevent interference with the monitoring equipment, while Ramírez et al. [42] included temperature sensors positioned at 2.0 m above floor level when investigating the indoor microclimate of a historic church. These studies provide methodological precedents for elevated sensor placement in historic buildings where practical constraints influence measurement locations. Nevertheless, the selected measurement height in the present study was intended to characterize thermal conditions at the monitoring locations rather than to assess occupant-level thermal comfort. Since measurements were not conducted at multiple heights, potential vertical temperature stratification within the rooms could not be evaluated. This limitation should be considered when interpreting the measured temperature differences and their implications for indoor thermal performance.
This study primarily examines the relationship between eyvan configuration and volume and the thermal performance of adjacent rooms. To improve comparability among the selected cases, all examined eyvans are located on the ground floor and oriented toward the north. However, because the investigated cases are existing historic buildings rather than experimentally controlled replicas, they inherently differ in architectural characteristics such as adjacent room dimensions, ceiling heights, window arrangements, and specific envelope properties. Consequently, the measured differences cannot be attributed exclusively to eyvan configuration or volume. The results should therefore be interpreted as case-specific associations reflecting the combined thermal behavior of each building.
A primary limitation of this study is the inability to conduct the necessary assessments to determine comprehensive thermal comfort parameters, such as the Predicted Mean Vote (PMV), the Predicted Percentage of Dissatisfied (PPD), and operative temperature. Due to spatial and functional constraints within these historic sites, which remain in active use and are classified as cultural heritage, it was not feasible to install complex equipment, such as globe thermometers or anemometers, in the centers of the rooms, nor was it possible to strictly control dynamic boundary conditions such as daily door/window operation, transient occupancy, and internal heat gains. Consequently, rather than providing a holistic evaluation of user thermal comfort, this study aims to demonstrate the passive cooling and thermal moderation potential of eyvans by analyzing air temperature drops and Cooling Degree-Hours (CDH) data. Future research should incorporate localized, short-term measurements of mean radiant temperature and air velocity to enable reliable PMV and PPD calculations.
In addition to the limitations associated with thermal comfort measurements, several environmental and operational conditions that may influence indoor thermal behavior were not systematically monitored during the measurement period. These include local air movement, incident solar radiation, surface temperatures, door and window operation, occupancy levels, and internal heat gains. Furthermore, although courtyard watering was observed in the single-arched case (1A), the amount of water applied and the associated evaporation rates were not quantified. Variations in these environmental and operational conditions may have contributed to the differences in indoor temperature and relative humidity observed among the investigated buildings. Consequently, the measured thermal differences reflect the combined influence of architectural characteristics and operating conditions rather than the isolated effect of eyvan configuration or volume. These limitations should be considered when interpreting the comparative results and their implications for passive cooling performance.
In the context of measurement uncertainty, the Extech RHT10 data loggers have a manufacturer-specified temperature accuracy of ±1.0 °C within the −10 to 40 °C range and a relative humidity accuracy of ±3% RH. Although identical instruments were used in all three buildings, differences in individual sensor errors may influence the measured temperature differences. Assuming that the temperature measurements remain within the specified accuracy limits, the maximum possible instrumental error in the temperature difference between two independently monitored spaces is ±2.0 °C. This conservative bound should be considered when interpreting the relatively small temperature differences observed between the investigated cases. Furthermore, systematic measurement errors are not necessarily reduced through temporal averaging. The calculated Cooling Degree-Hours (CDH) are also subject to temperature measurement uncertainty, particularly when indoor temperatures are close to the selected reference threshold of 26 °C. Consequently, the reported temperature differences and CDH values should be interpreted as descriptive indicators of the observed thermal conditions rather than precise measures of the isolated effects of eyvan configuration.
In addition to instrumental uncertainty, the statistical interpretation of the results is limited by the study design and the temporal characteristics of the measurements. Although temperature and relative humidity were recorded at 30-min intervals throughout the summer monitoring period, successive observations within each building are temporally correlated and cannot be considered independent experimental replicates. Furthermore, only one building was investigated for each eyvan configuration, preventing the statistical separation of eyvan geometry effects from other building-specific characteristics. While hourly and weekly averages were used to describe temporal variations in the measured thermal conditions, these aggregations do not eliminate the influence of temporal correlation or uncontrolled architectural and operational factors. Consequently, the available data do not provide a sufficient basis for establishing statistically significant effects of the number of arches or the eyvan-to-room volume ratio. The observed temperature differences should therefore be interpreted as exploratory, descriptive comparisons of the three investigated buildings rather than statistically validated or generalizable relationships. Further investigations involving multiple buildings with comparable architectural characteristics for each eyvan configuration would be necessary to evaluate the robustness and statistical significance of these relationships.
4. Results and Discussion
4.1. Temperature Measurements and Comparative Analysis
Temperature values measured in the selected mansions during June, July, and August 2022 are presented in graphs. For each mansion, indoor temperature values were compared with outdoor temperature. According to the outdoor climate data for June, July, and August 2022 obtained from The Weather Company (IBM), the average air temperature during this period was 30.4 °C. The highest air temperature was 44 °C, recorded on August 5, while the lowest air temperature was 15 °C, recorded on June 6 (Figure 9).
Figure 9.
Outdoor temperature (June–July–August) values for Diyarbakır province.
According to the indoor temperature data of space 1A (Figure 10a), which has a single-arch eyvan, the average temperature during this period was 32.79 °C. The highest recorded indoor temperature was 36.8 °C on 16 July 2022, while the lowest was 27 °C on 17 June 2022. For space 2A (Figure 10b), which has a double-arch eyvan, the average indoor temperature during this period was 31.05 °C. The highest recorded indoor temperature was 32.9 °C on 6–7 August 2022, and the lowest was 24.6 °C on 26 June 2022. For space 3A (Figure 10c), which has a triple-arch eyvan, the average indoor temperature during this period was 29.21 °C. The highest recorded indoor temperature was 32.9 °C on 6–7 August 2022, while the lowest was 24.2 °C on 1 June 2022.
Figure 10.
Indoor minimum, maximum, and average temperatures during June–August 2022 for the three investigated eyvan configurations: (a) single-arched (1A), (b) double-arched (2A), and (c) triple-arched (3A).
To compare the indoor thermal conditions of the three investigated buildings during the hot–dry period, the weekly average indoor temperatures were analysed, and the differences between the cases were calculated using the 13 observations presented in Figure 11. The maximum temperature difference between 1A and 2A was 2.90 °C, recorded for the observation dated 26 July 2022. The maximum difference between 2A and 3A was 3.10 °C, while the maximum difference between 1A and 3A was 4.80 °C, both recorded for the observation dated 7 June 2022. Throughout the investigated period, the lowest weekly average indoor temperatures were generally observed in 3A, followed by 2A and 1A. These differences indicate a consistent descriptive trend among the three buildings; however, they cannot be attributed exclusively to eyvan configuration because other architectural and operational characteristics also vary between the investigated cases.
Figure 11.
Comparison of indoor temperatures among the single-arched (1A), double-arched (2A), and triple-arched (3A) cases.
During the hot period, outdoor air temperature varied between an average of 44 °C and 15 °C, while indoor temperatures ranged between 36.8 °C and 27 °C in 1A, 34.9 °C and 24.6 °C in 2A, and 32.9 °C and 24.2 °C in 3A. Throughout the hot period, when outdoor temperatures reached their highest values between 35 °C and 44 °C during midday hours, indoor temperatures varied between 36.8 °C and 32.1 °C in 1A, 34.9 °C and 30.7 °C in 2A, and 32.9 °C and 28 °C in 3A. During midday hours, lower indoor temperatures were recorded in all three mansions compared with the corresponding outdoor conditions. These differences indicate thermal moderation within the investigated buildings, although the individual contributions of eyvan configuration, building-envelope characteristics, and operational conditions could not be isolated. During the period when the highest outdoor temperature of 44 °C was recorded (3 August 2022–9 August 2022), the maximum indoor temperatures were measured as 34.9 °C in 1A, 34.9 °C in 2A, and 32.9 °C in 3A (Figure 12).
Figure 12.
Comparison of indoor air temperatures measured in the three investigated buildings (1A, 2A, and 3A) with outdoor air temperature, June–August 2022.
During the measurement period, in the midday hours (12:00–15:00) when solar radiation reaches its highest level, the average outdoor temperature was 37.29 °C, while the average indoor temperatures were 33.02 °C in 1A, 31.17 °C in 2A, and 29.33 °C in 3A. Based on the temperature averages recorded during the hottest period of the day, the temperature difference between 3A and the outdoor environment was 7.96 °C, between 2A and the outdoor environment was 6.12 °C, and between 1A and the outdoor environment was 4.27 °C (Figure 13).
Figure 13.
Comparison of indoor air temperatures measured in the three investigated buildings (1A, 2A, and 3A) with outdoor air temperature data during peak hours (12:00–15:00), June–August 2022.
Figure 14 presents the average indoor–outdoor temperature differences observed during peak hours (12:00–15:00) over the measurement period. The average indoor temperatures were 4.27 °C lower than the outdoor temperature in 1A, 6.12 °C lower in 2A, and 7.96 °C lower in 3A. These differences reflect the combined thermal buffering of the traditional building configurations, including shading, thermal mass, and the spatial relationship between the eyvan and adjacent indoor spaces. Among the three investigated cases, the largest temperature difference was observed in 3A, which had the largest eyvan configuration.
Figure 14.
Average indoor–outdoor temperature difference during peak hours (12:00–15:00).
While indoor temperature reductions during peak hours indicate thermal moderation relative to outdoor conditions, they do not provide a comprehensive assessment of occupant thermal comfort. To further characterize the thermal conditions in the investigated buildings, Cooling Degree-Hours (CDH) were calculated as an indicator of cumulative indoor temperature exceedance above the selected reference threshold of 26 °C. Figure 15 presents the total CDH values calculated over the summer measurement period for the three investigated cases. The calculated values were 14,905 °C·h for 1A, 11,175 °C·h for 2A, and 7161 °C·h for 3A. The CDH value for 3A was approximately 52% lower than that for 1A, indicating substantially lower cumulative temperature exceedance in the investigated building with the largest eyvan configuration. However, this difference reflects the combined thermal characteristics of the individual buildings and cannot be attributed exclusively to eyvan configuration or volume.
Figure 15.
Cooling Degree-Hours (CDH) for the three investigated cases from 1 June to 31 August 2022.
4.2. Humidity Measurements and Comparative Analysis
Relative humidity values measured in the selected mansions during June, July, and August 2022 are presented in graphs. For each mansion, indoor humidity values were compared with outdoor humidity values. According to the outdoor climate data for June, July, and August 2022 obtained from The Weather Company (IBM), the average humidity level during this period was 26.13%. The highest humidity level was 94%, recorded on June 25, while the lowest humidity level was 4%, recorded on August 28 (Figure 16).
Figure 16.
Outdoor relative humidity values of Diyarbakır province, June–August 2022.
According to the indoor humidity data of space 1A, which has a single-arch eyvan, the average humidity value during June, July, and August 2022 was 28.30%. The highest recorded indoor humidity was 57.60% on 17 June 2022, while the lowest was 13.50% on 5 June 2022. For space 2A, which has a double-arch eyvan, the average indoor humidity during the same period was 24%. The highest recorded indoor humidity was 46.30% on 25 June 2022, and the lowest was 10.30% on 23 July 2022. For space 3A, which has a triple-arch eyvan, the average indoor humidity during June, July, and August 2022 was 30.85%. The highest recorded indoor humidity was 49.10% on 25 June 2022, while the lowest was 13.8% on 28 August 2022 (Figure 17).
Figure 17.
Indoor minimum, maximum, and average relative humidity during June–August 2022 for the three investigated eyvan configurations: (a) single-arched (1A), (b) double-arched (2A), and (c) triple-arched (3A).
The indoor relative humidity measurements from the three investigated buildings were compared with the corresponding outdoor humidity data obtained from The Weather Company (Figure 18). Differences in relative humidity were observed among the investigated cases and between indoor and outdoor conditions. In the single-arched case (1A), regular courtyard watering was observed during the measurement period. The porous basalt flooring may retain moisture and potentially influence the local humidity conditions. However, the amount of water applied, surface moisture conditions, evaporation rates, air movement, and associated latent cooling effects were not quantitatively measured. Furthermore, relative humidity depends on both air temperature and water vapor content; therefore, differences in relative humidity do not necessarily indicate corresponding differences in absolute moisture content. Consequently, although courtyard watering and the properties of the basalt flooring may have influenced the observed humidity variations, their individual contributions cannot be established from the available measurements. The relative-humidity results should therefore be interpreted as descriptive observations rather than direct evidence of evaporative cooling or a specific moisture-transfer mechanism.
Figure 18.
Comparison of indoor relative humidity measured in the three investigated buildings (1A, 2A, and 3A) with outdoor relative humidity data during peak hours (12:00–15:00), June–August 2022.
When the daily average indoor temperature data of the three mansions were analyzed, it was found that indoor temperatures in 3A were lower than those in 2A, and indoor temperatures in 2A were lower than those in 1A. In hot–dry climates, high-temperature levels are accompanied by low-humidity levels. Figure 19 shows that the outdoor air temperature in Diyarbakır is high, while the humidity level is low.
Figure 19.
Comparison of outdoor temperature and relative humidity values, June–August 2022.
In addition, in all three mansions, it was observed that while indoor temperature increases during the hot period, humidity levels decrease. The indoor temperature of 3A was generally lower than those of 2A and 1A, while its relative humidity was generally higher (Figure 20). However, these observations do not establish whether the differences in relative humidity resulted primarily from temperature variations, differences in moisture content, or other environmental and operational conditions.
Figure 20.
Comparison of indoor temperature and relative humidity during June–August 2022 for the three investigated eyvan configurations: (a) single-arched (1A), (b) double-arched (2A), and (c) triple-arched (3A).
4.3. Unit Volume-Temperature Relationship
In the three investigated traditional Diyarbakır courtyard houses, differences in eyvan configuration and geometry were associated with variations in the indoor temperatures of adjacent rooms. The average indoor temperatures recorded during the summer measurement period were 32.79 °C in the single-arched case (1A), 31.05 °C in the double-arched case (2A), and 29.21 °C in the triple-arched case (3A). Accordingly, the lowest average indoor temperature was observed in İskender Paşa Mansion (3A), which had the largest eyvan configuration. However, each configuration was investigated in a different historic building, and potentially influential characteristics, including adjacent room dimensions, window arrangements, building-envelope properties, and operational conditions, could not be experimentally controlled. Therefore, the observed temperature differences cannot be attributed exclusively to the number of arches or eyvan volume. Rather, they represent case-specific associations reflecting the combined thermal characteristics of the investigated buildings. The temperature differences between the three cases are summarized in Table 5 and should be interpreted as descriptive comparisons rather than evidence of a fixed temperature reduction resulting from additional arches.
Previous field investigations have demonstrated the potential of traditional courtyards and associated semi-open spaces to moderate thermal conditions under different climatic conditions [43,44]. Furthermore, numerical investigations have shown that courtyard geometry and shading elements can influence passive cooling performance [45].
The volumes of eyvans and the adjacent rooms in the measured mansions were compared, and the eyvan-to-room volume ratio was calculated. Based on the geometric volume calculations, the eyvan-to-room volume ratios were 1.36 for 1A, 1.62 for 2A, and 1.89 for 3A (Table 6).
Table 6.
Calculation of eyvan-to-room volume ratios for the three investigated cases.
The eyvan-to-room volume ratios calculated for the three investigated buildings were 1.36 for 1A, 1.62 for 2A, and 1.89 for 3A (Table 6). The relative volume-ratio factors between consecutive cases were approximately 1.19 for 2A/1A and 1.17 for 3A/2A. Based on the 13 weekly average-temperature observations, the corresponding mean indoor temperature differences were 1.76 °C and 1.82 °C, respectively, while the overall difference between 1A and 3A was 3.58 °C (Table 7). Across the three investigated buildings, larger eyvan-to-room volume ratios were associated with lower average indoor temperatures, as illustrated in Figure 21. However, these relationships are based on only three architecturally distinct buildings, and the observed temperature differences cannot be attributed exclusively to eyvan geometry or volume. Therefore, the results should be interpreted as descriptive, case-specific associations rather than generalized quantitative design relationships.
Table 7.
Descriptive comparison of eyvan-to-room volume ratios and indoor temperature differences between the investigated cases.
Figure 21.
Descriptive relationship between the eyvan-to-room volume ratio and the average indoor temperature during June–August 2022 for the three investigated cases: single-arched (1A), double-arched (2A), and triple-arched (3A).
4.4. Implications for Climate-Responsive and Contemporary Building Design
The findings provide quantitative field evidence of the thermal performance associated with a traditional spatial strategy developed in response to the hot–dry climate of Diyarbakır. The eyvan can therefore be considered not only as a characteristic element of traditional courtyard-house architecture, but also as part of a regionally adapted passive design approach. Within the three investigated cases, larger eyvan configurations were consistently associated with lower indoor temperatures and lower Cooling Degree-Hours during the summer measurement period. For contemporary building design, the relevance of these findings lies primarily in the underlying passive design principles rather than in the direct reproduction of the traditional eyvan form. This allows the study’s findings to be interpreted from a perspective that extends beyond the scale of the local case studies. The use of shaded semi-open transitional spaces, appropriate orientation, and spatial configurations that reduce the direct exposure of adjacent indoor spaces to solar radiation may contribute to improved summer thermal conditions in hot–dry climates. However, the quantitative relationships identified in this study are specific to the three investigated historic buildings and their particular architectural, material, and climatic conditions. Their applicability to contemporary buildings should therefore be further evaluated through controlled measurements and building energy simulations before generalized design recommendations are established.
The findings of the present study can be discussed in relation to previous investigations of traditional iwans, courtyards, and semi-open transitional spaces. Eskandari et al. [16] examined the influence of iwan geometry and orientation on building thermal loads under different climatic conditions, demonstrating the relevance of these architectural parameters to passive building performance. Similarly, Diz-Mellado et al. [22] reported that traditional courtyards can provide substantial thermal moderation during hot periods, highlighting the importance of shading in semi-open spaces. However, Guedouh et al. [20] demonstrated that the thermal and daylighting performance of courtyard buildings involves trade-offs, indicating that the effects of architectural morphology depend on the specific configuration and environmental conditions. Furthermore, Khan et al. [45] showed through numerical simulations that courtyard dimensions and additional shading elements can influence passive cooling and night-time thermal behavior.
In comparison with these studies, the present research contributes comparative field measurements of indoor thermal conditions associated with single-, double-, and triple-arched eyvan configurations in three traditional Diyarbakır courtyard houses. The observed differences in indoor temperatures and Cooling Degree-Hours (CDH) are consistent with the broader potential of shaded transitional spaces to moderate thermal conditions. However, the findings cannot be directly compared quantitatively with studies investigating different geometries, climatic conditions, or thermal performance indicators. Moreover, because each eyvan configuration was investigated in a different building, the observed temperature differences cannot be attributed exclusively to eyvan geometry or volume. Nevertheless, the results provide additional empirical evidence that may inform future controlled investigations and the development of climate-responsive passive design strategies for contemporary buildings.
5. Conclusions
This study examined the thermal performance associated with different eyvan configurations in three traditional Diyarbakır courtyard houses under hot–dry summer conditions. Based on the findings obtained from the three investigated mansions, the following conclusions were drawn:
In the studied buildings, the eyvan configurations were associated with lower indoor temperatures during the summer period, reflecting the combined influence of shading, reduced direct solar exposure, and the thermal characteristics of the traditional buildings.
Throughout the measurement period, indoor temperatures in the spaces adjacent to the eyvans remained consistently lower than the extreme outdoor summer temperatures. The lowest indoor temperatures were observed in 3A (triple-arched eyvan), whereas 1A (single-arched eyvan) exhibited the highest values among the three cases. These results show a consistent trend in which larger eyvan configurations were associated with more favourable indoor thermal conditions during hot periods.
No consistent relationship was established between relative humidity and the number of arches forming the eyvan during the measurement period. Differences in relative humidity were observed among the investigated buildings, potentially reflecting variations in air temperature, courtyard conditions, and other environmental factors. Although courtyard watering was observed in 1A and the porous basalt flooring may influence local moisture conditions, the absence of direct measurements of evaporation and moisture transfer prevents a quantitative assessment of these mechanisms. The relative-humidity findings should therefore be interpreted as descriptive observations rather than evidence of a specific cooling mechanism.
During peak daytime hours, the indoor temperatures in all three configurations were substantially lower than the outdoor averages. These differences reflect the combined thermal characteristics of the investigated buildings, with the largest indoor–outdoor temperature difference observed in 3A, which had the largest eyvan configuration.
The Cooling Degree-Hours (CDH) analysis revealed differences in cumulative indoor temperature exceedance among the investigated buildings. The lowest CDH value was observed in 3A, indicating lower exposure to temperatures above the selected reference threshold during the summer measurement period. However, these differences should not be interpreted as direct evidence of reduced cooling-energy consumption.
The 3A case exhibited a substantially lower CDH value compared to 1A, indicating a significantly reduced exposure to summer overheating.
A consistent relationship was observed between the eyvan-to-room volume ratio and indoor temperature across the three investigated cases. Increases in the eyvan-to-room volume ratio were associated with corresponding decreases in average indoor temperatures. However, this relationship should be interpreted as case-specific rather than as a universal design rule, since the thermal behaviour of the investigated buildings is also influenced by their material properties, thermal mass, courtyard conditions, and other architectural characteristics.
Overall, the findings provide quantitative field evidence supporting the climatic logic embedded in traditional Diyarbakır courtyard-house design. The eyvan represents a regionally adapted passive architectural strategy in which spatial configuration, shading, and the relationship between semi-open and indoor spaces contribute to the moderation of summer thermal conditions. In this respect, the study demonstrates how traditional architectural knowledge can be evaluated through contemporary building-performance methods rather than considered solely from formal or typological perspectives.
Therefore, the originality of this research lies in providing comparative quantitative field evidence of indoor thermal conditions associated with single-, double-, and triple-arched eyvan configurations in traditional Diyarbakır courtyard houses. Beyond the formal and typological analyses that characterize much of the existing literature, this study combines field measurements with comparative temperature and Cooling Degree-Hours (CDH) analyses to investigate the thermal moderation associated with these traditional spatial configurations. Although the study focuses on three historic buildings in Diyarbakır, the underlying passive design principles, such as the use of shaded, semi-open transitional spaces to moderate indoor temperatures, may have broader relevance for contemporary building design in hot–dry climates. However, the observed relationships are case-specific, and the influence of eyvan geometry and volumetric proportions requires further investigation under different architectural and climatic conditions before generalized design recommendations can be established.
For contemporary buildings in hot–dry regions, the principal value of the eyvan lies in the passive design principles that it represents rather than in the direct reproduction of its traditional form. The integration of shaded transitional spaces and climate-responsive spatial configurations may contribute to reducing overheating and dependence on active cooling. Future research should evaluate these principles in contemporary building configurations through controlled measurements and building energy simulations and should examine a wider range of eyvan-to-room volume ratios, geometries, materials, and climatic conditions.
Author Contributions
Conceptualization, İ.H.Ş., Ş.E. and B.Ş.; methodology, İ.H.Ş., Ş.E., B.Ş. and H.Y.; formal analysis, İ.H.Ş., Ş.E., B.Ş., H.Y. and A.A.; data curation, İ.H.Ş., Ş.E. and B.Ş.; visualization, İ.H.Ş., Ş.E., B.Ş. and H.Y.; writing—original draft preparation, İ.H.Ş., Ş.E. and B.Ş.; writing—review and editing, İ.H.Ş., Ş.E., B.Ş., H.Y. and A.A.; project administration, A.A. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Data Availability Statement
Data is contained within the article.
Acknowledgments
This manuscript is based on the master’s thesis of İbrahim Halil Şeker.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Nguyen, A.-T.; Tran, Q.-B.; Tran, D.-Q.; Reiter, S. An Investigation on Climate Responsive Design Strategies of Vernacular Housing in Vietnam. Build. Environ. 2011, 46, 2088–2106. [Google Scholar] [CrossRef] [Scilit]
- Ding, D.; Xu, Y. Path to Net Zero: Understanding the Building Energy Efficiency in Different Climates across Various Building Types. Highlights Sustain. 2024, 3, 308–337. [Google Scholar] [CrossRef] [Scilit]
- Molloy, S.B.; Cheng, M.; Galbally, I.E.; Keywood, M.D.; Lawson, S.J.; Powell, J.C.; Gillett, R.; Dunne, E.; Selleck, P.W. Indoor Air Quality in Typical Temperate Zone Australian Dwellings. Atmos. Environ. 2012, 54, 400–407. [Google Scholar] [CrossRef] [Scilit]
- Duan, Z.; Omrany, H.; Zuo, J. Impact of Climate Change on Energy Performance and Energy Conservation Measures Effectiveness in Australian Office Buildings. Energy 2025, 319, 134956. [Google Scholar] [CrossRef] [Scilit]
- Yin, X.; Muhieldeen, M.W. Evaluation of Cooling Energy Saving and Ventilation Renovations in Office Buildings by Combining Bioclimatic Design Strategies with CFD-BEM Coupled Simulation. J. Build. Eng. 2024, 91, 109547. [Google Scholar] [CrossRef] [Scilit]
- Wang, C.; Song, J.; Shi, D.; Reyna, J.L.; Horsey, H.; Feron, S.; Zhou, Y.; Ouyang, Z.; Li, Y.; Jackson, R.B. Impacts of Climate Change, Population Growth, and Power Sector Decarbonization on Urban Building Energy Use. Nat. Commun. 2023, 14, 6434. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ayoobi, A.W.; Ekimci, B.G.; Inceoğlu, M.; Ayoobi, A.W.; Ekimci, B.G.; Inceoğlu, M. A Comparative Study of Sustainable Cooling Approaches: Evaluating the Performance of Natural Ventilation Strategies in Arid and Semi-Arid Regions. Buildings 2024, 14, 3995. [Google Scholar] [CrossRef] [Scilit]
- Pouranian, F.; Akbari, H.; Hosseinalipour, S.M. Performance Assessment of Solar Chimney Coupled with Earth-to-Air Heat Exchanger: A Passive Alternative for an Indoor Swimming Pool Ventilation in Hot-Arid Climate. Appl. Energy 2021, 299, 117201. [Google Scholar] [CrossRef] [Scilit]
- Johansson, T.B.; Nakicenovic, N.; Patwardhan, A.; Gomez-Echeverri, L.; Arent, D.J.; Banerjee, R.; Benson, S.M.; Bouille, D.H.; Brew-Hammond, A.; Cherp, A.; et al. Technical Summary. In Global Energy Assessment: Toward a Sustainable Future; Global Energy Assessment Writing Team, Ed.; Cambridge University Press: Cambridge, UK, 2012; pp. 31–94. [Google Scholar]
- Szczepanik-Scislo, N.; Scislo, L. Dynamic Real-Time Measurements and a Comparison of Gas and Wood Furnaces in a Dual-Fuel Heating System in Order to Evaluate the Occupants’ Safety and Indoor Air Quality. Buildings 2023, 13, 2125. [Google Scholar] [CrossRef] [Scilit]
- Amirifard, F.; Sharif, S.A.; Nasiri, F. Application of Passive Measures for Energy Conservation in Buildings—A Review. Adv. Build. Energy Res. 2019, 13, 282–315. [Google Scholar] [CrossRef] [Scilit]
- Balali, A.; Hakimelahi, A.; Valipour, A. Identification and Prioritization of Passive Energy Consumption Optimization Measures in the Building Industry: An Iranian Case Study. J. Build. Eng. 2020, 30, 101239. [Google Scholar] [CrossRef] [Scilit]
- Konstantinou, T.; Knaack, U. An Approach to Integrate Energy Efficiency Upgrade into Refurbishment Design Process, Applied in Two Case-Study Buildings in Northern European Climate. Energy Build. 2013, 59, 301–309. [Google Scholar] [CrossRef] [Scilit]
- Baboli, F.B.M.; Ibrahim, N.; Sharif, D.M. Design Characteristics and Adaptive Role of the Traditional Courtyard Houses in the Moderate Climate of Iran. Procedia-Soc. Behav. Sci. 2015, 201, 213–223. [Google Scholar] [CrossRef] [Scilit]
- Erarslan, A. The Iwan-Courtyard House Culture in the Region of Southeastern Anatolia. Pro Ligno 2021, 17, 24–35. [Google Scholar]
- Eskandari, H.; Saedvandi, M.; Mahdavinejad, M. The Impact of Iwan as a Traditional Shading Device on the Building Energy Consumption. Buildings 2018, 8, 3. [Google Scholar] [CrossRef] [Scilit]
- Moradchelleh, A.; Rashid, H. The Study of the Form of the Building in Climates of Iran. Middle-East J. Sci. Res. 2011, 8, 306–313. [Google Scholar]
- Ayçam, İ.; Akalp, S.; Görgülü, L.S. The Application of Courtyard and Settlement Layouts of the Traditional Diyarbakır Houses to Contemporary Houses: A Case Study on the Analysis of Energy Performance. Energies 2020, 13, 587. [Google Scholar] [CrossRef] [Scilit]
- Ergin, Ş.; Suna Gider, K.; Şeker, İ.H.; Yildizhan, H.; Ameen, A. Effects of Urban Street Geometry and Traditional Kabalti Passages on Building Surface Temperature in a Hot-Dry Climate. Sci. Rep. 2026, 16, 888. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Guedouh, M.S.; Zemmouri, N.; Hanafi, A.; Qaoud, R. Passive Strategy Based on Courtyard Building Morphology Impact on Thermal and Luminous Environments in Hot and Arid Region. Energy Procedia 2019, 157, 435–442. [Google Scholar] [CrossRef] [Scilit]
- Al-Hafith, O.; Satish, B.K.; Bradbury, S.; de Wilde, P. Simulation of Courtyard Spaces in a Desert Climate. Energy Procedia 2017, 142, 1997–2002. [Google Scholar] [CrossRef] [Scilit]
- Diz-Mellado, E.; López-Cabeza, V.P.; Rivera-Gómez, C.; Galán-Marín, C.; Rojas-Fernández, J.; Nikolopoulou, M. Extending the Adaptive Thermal Comfort Models for Courtyards. Build. Environ. 2021, 203, 108094. [Google Scholar] [CrossRef] [Scilit]
- Almumar, M.M.S. Understanding the Environmental Performance of the Iraqi Traditional Courtyard House, Is There an Order of Façades Orientation in Randomly Oriented Land Plots? J. Build. Eng. 2019, 22, 140–146. [Google Scholar] [CrossRef] [Scilit]
- de la Flor, F.J.S.; Ruiz-Pardo, Á.; Diz-Mellado, E.; Rivera-Gómez, C.; Galán-Marín, C. Assessing the Impact of Courtyards in Cooling Energy Demand in Buildings. J. Clean. Prod. 2021, 320, 128742. [Google Scholar] [CrossRef] [Scilit]
- Abuhussain, M.A.; Al-Tamimi, N.; Alotaibi, B.S.; Singh, M.K.; Kumar, S.; Elnaklah, R. Impact of Courtyard Concept on Energy Efficiency and Home Privacy in Saudi Arabia. Energies 2022, 15, 5637. [Google Scholar] [CrossRef] [Scilit]
- Helali, S.S. Geleneksel İran Evlerinde Sürdürülebilir Mimarlık Açısından Avlunun Rolü; Yüksek Lisans Tezi, İstanbul Aydın Üniversitesi, Fen Bilimleri Enstitüsü, Mimarlık Ana Bilim Dalı: İstanbul, Turkey, 2019. [Google Scholar]
- Ibrahim, Y.; Kershaw, T.; Shepherd, P.; Elkady, H. Multi-Objective Optimisation of Urban Courtyard Blocks in Hot Arid Zones. Sol. Energy 2022, 240, 104–120. [Google Scholar] [CrossRef] [Scilit]
- Beysanoğlu, Ş. Anıtları Ve Kitabeleri Ile Diyarbakır Tarihi; Diyarbakır Tanıtma ve Turizm Derneği Yayınları: Diyarbakır, Turkey, 1963. [Google Scholar]
- Gabriel, A. Anadolu’da Türk Evleri; Yapı Kredi Yayınları: İstanbul, Turkey, 1993. [Google Scholar]
- Manioğlu, G.; Yılmaz, Z. Energy Efficient Design Strategies in the Hot Dry Area of Turkey. Build. Environ. 2008, 43, 1301–1309. [Google Scholar] [CrossRef] [Scilit]
- Dalkılıç, N.; Nabikoğlu, A. The Architectural Features of the Diyarbakir City Walls: A Report on Current Status and Issues of Conservation. Mediterr. Archaeol. Archaeom. 2012, 12, 171–182. [Google Scholar]
- Google Earth Pro; Google LLC: Mountain View, CA, USA, 2026.
- Bölük, E.; Eskioğlu, O.; Çalık, Y.; Yağan, S. Aydeniz Iklim Siniflandirmasina Göre Türkiye Iklimi; Meteoroloji Genel Müdürlüğü: Ankara, Turkey, 2024. [Google Scholar]
- Turkish State Meteorological Service. 2022 Yaz Mevsimi Maksimum Sıcaklık Haritası; Çevre, Şehircilik ve İklim Değişikliği Bakanlığı: Ankara, Turkey, 2022. [Google Scholar]
- Kuban, D. Sanat Tarihimizin Sorunları; Çağdaş Yayınları: İstanbul, Turkey, 1975. [Google Scholar]
- Downey, S.B. Mesopotamian Religious Architecture: Alexander Through the Parthians; Princeton University Press: Princeton, NJ, USA, 1988. [Google Scholar]
- Eldem, S.H. Türk Evi Plan Tipleri—Sedad Hakkı ELDEM; Mimarlık Fakültesi, İstanbul Teknik Üniversitesi: İstanbul, Turkey, 1954. [Google Scholar]
- Tuncer, O.C. Diyarbakır Evleri; Diyarbakır Büyükşehir Belediyesi Kültür ve Sanat Yayınları: Ankara, Turkey, 1999. [Google Scholar]
- Şeker, İ.H. Geleneksel Diyarbakır Konutlarında Eyvan Planlamalarının Mekanların Isıl Performansına Etkisi. Master Thesis, Dicle University, Diyarbakır, Turkey, 2022. [Google Scholar]
- Kyriakopoulos, P.; Giannopoulos, A.; Caouris, Y.G.; Souliotis, M.; Santamouris, M. Degree-Hours and Degree-Days in Coastal Mediterranean Cities, Patras and Kalamata, Greece. Adv. Environ. Eng. Res. 2021, 2, 32. [Google Scholar] [CrossRef] [Scilit]
- Khei, S.; Mateus, R.; Ortega, J.; Briones-Llorente, R. Multiscale Framework for Bioclimatic Adaptation: Quantifying the Passive Performance of High-Mass Vernacular Heritage. Appl. Sci. 2026, 16, 2839. [Google Scholar] [CrossRef] [Scilit]
- Ramírez, S.; Zarzo, M.; Perles, A.; García-Diego, F.-J. Characterization of Temperature Gradients According to Height in a Baroque Church by Means of Wireless Sensors. Sensors 2021, 21, 6921. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hao, S.; Yu, C.; Xu, Y.; Song, Y. The Effects of Courtyards on the Thermal Performance of a Vernacular House in a Hot-Summer and Cold-Winter Climate. Energies 2019, 12, 1042. [Google Scholar] [CrossRef] [Scilit]
- Diz-Mellado, E.; López-Cabeza, V.P.; Rivera-Gómez, C.; Galán-Marín, C. Seasonal Analysis of Thermal Comfort in Mediterranean Social Courtyards: A Comparative Study. J. Build. Eng. 2023, 78, 107756. [Google Scholar] [CrossRef] [Scilit]
- Khan, H.M.; Lane-Serff, G.F.; Dewsbury, J. Optimizing the Design of Courtyard Houses for Passive Cooling in Hot, Dry Regions. J. Build. Perform. Simul. 2023, 16, 231–247. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.