Skip to Content
BuildingsBuildings
  • Article
  • Open Access

20 November 2026

27 Pages

Full-Scale LSF Experimental Research Facilities at the University of Coimbra Campus: Design, Scientific Outcomes, and Future Perspectives

,
,
and
1
Universidade de Coimbra, ISISE, ARISE, Departamento de Engenharia Civil, Rua Luís Reis Santos—Pólo 2, 3030-788 Coimbra, Portugal
2
Escuela Técnica Superior de Edificación, Universidad Politécnica de Madrid, 28040 Madrid, Spain
*
Author to whom correspondence should be addressed.
Buildings2026, 16(22), 4641;https://doi.org/10.3390/buildings16224641 
(registering DOI)
This article belongs to the Special Issue Innovations and Emerging Technologies in Modular and Prefabricated Building Systems

Abstract

The thermal and hygrothermal performance of Lightweight Steel Frame (LSF) buildings has been extensively investigated, particularly regarding thermal bridging, heat transfer through building envelopes, and the integration of passive solar technologies. However, relatively little attention has been given to the long-term operation and scientific exploitation of permanent, full-scale experimental research infrastructures that can support successive experimental investigations and numerical model validation under real operating conditions. This paper presents the design, development, and long-term operation of a permanent, full-scale experimental research infrastructure comprising two LSF modules installed at the Department of Civil Engineering of the University of Coimbra, Portugal, one of which incorporates a Trombe wall. The facility, established in 2017, was developed to investigate the hygrothermal behaviour, thermal response and energy performance of LSF building envelopes under local (Mediterranean) climatic conditions. The two identical full-scale modules enable direct comparison between the reference and modified configurations while maintaining the same boundary conditions. A comprehensive monitoring system records environmental variables, surface temperatures, and heat fluxes, providing a basis for analysing heat transfer mechanisms and validating numerical models. Based on successive monitoring campaigns, this paper synthesises the main scientific outcomes generated through the facility’s operation, focusing on thermal transmittance (U-value), thermal bridging, hygrothermal behaviour and passive solar technologies. For a representative validation case, good agreement was obtained between measured and simulated indoor temperatures, with root mean square error (RMSE) values of 0.3 °C and 0.5 °C for the reference and Trombe wall (TW) models, respectively. Experimental observations also showed that the TW configuration achieved higher daily average indoor temperatures and experienced a slower decrease in temperature after solar exposure, reflecting the storage and gradual release of solar heat. Although this study does not directly quantify energy savings, these findings demonstrate the facility’s value for investigating passive solar strategies and validating numerical approaches. Overall, this study provides a comprehensive overview of the scientific and educational contributions of a permanent, full-scale experimental facility, offering insights that could inform the development and operation of similar research infrastructures in other locations and climatic contexts.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.