Skip to Content
MachinesMachines
  • Article
  • Open Access

9 January 2026

26 Pages

Two-Stage Harmonic Optimization-Gram Based on Spectral Amplitude Modulation for Rolling Bearing Fault Diagnosis

,
,
,
,
,
and
1
College of Science and Technology, Ningbo University, Ningbo 315211, China
2
Ningbo Donghuang Bearing Co., Ltd., Ningbo 315318, China
*
Author to whom correspondence should be addressed.

Abstract

To address the challenge of effectively extracting early-stage failure features in rolling bearings, this paper proposes a two-stage harmonic optimization-gram method based on spectral amplitude modulation (SAM-TSHOgram). The method first employs amplitude spectra with varying weighting exponents to preprocess the signal, performing nonlinear adjustments to the vibration signal’s spectrum to enhance weak periodic impact characteristics. Subsequently, a two-stage evaluation strategy based on spectral coherence (SCoh) was designed to adaptively identify the optimal frequency band (OFB). The first stage employs the Periodic Harmonic Correlation Strength (PHCS) metric, based on autocorrelation, to coarsely screen candidate bands with strong periodic structures. The second stage utilizes the Sparse Harmonic Significance (SHS) metric, based on spectral negative entropy, to refine the candidate set, selecting bands with the most prominent harmonic features. Finally, SCoh is integrated over the selected OFB to generate an Improved Envelope Spectrum (IES). The proposed method was validated using both simulated and experimental vibration signals from bearings and gearboxes. The results demonstrate that SAM-TSHOgram significantly outperforms conventional approaches such as EES, Fast Kurtogram, and IESFOgram in terms of signal-to-noise ratio (SNR) enhancement, harmonic clarity, and diagnostic robustness. These findings confirm its potential for reliable early fault detection in rolling bearings.

1. Introduction

Rolling element bearings (REBs) are critical components in rotating machinery, widely used in power generation, aerospace, transportation, and manufacturing industries, where they play an essential role in supporting shafts, transmitting motion, and enabling power conversion [1]. However, prolonged operation under heavy loads, strong friction, and harsh environments makes bearings susceptible to wear, cracks, and fatigue spalling. It is reported that nearly 30% of rotating machinery failures are bearing-related, and undetected early faults may cause unexpected shutdowns or even severe safety incidents, highlighting the importance of efficient early fault diagnosis [2,3]. When localized defects occur, periodic impacts are generated as rolling elements pass over the damaged area, producing weak transient pulses in vibration signals [4]. These fault features are often masked or distorted by sensor placement, transmission path effects, and strong noise, making it extremely difficult to extract weak fault-related frequency components, especially under low signal-to-noise ratio (SNR) conditions.
Over the past decades, various signal processing techniques have been developed to address this issue. Traditional envelope spectrum (ES) and square envelope spectrum (SES) analyses can demodulate impact responses but are highly susceptible to harmonic interference under noisy conditions, leading to low feature recognition accuracy. Building on the spectral kurtosis framework [5,6], Antoni [7] introduced the Fast Kurtogram (FK) method, which utilizes kurtosis as an indicator combined with a 1/3-octave filter bank for adaptive resonance band selection. This concept has inspired further improvements based on entropy difference [8,9], Gini index [10], and autocorrelation [11]. However, methods relying solely on statistical metrics have inherent limitations. Metrics such as kurtosis and Gini coefficients are susceptible to false non-Gaussian noise or random outliers, which can drive statistical maximization even in the absence of periodic fault characteristics. This leads to selecting optimal frequency bands (OFBs) dominated by random disturbances rather than target fault features, particularly under low SNR conditions.
Spectral correlation (SC) and spectral coherence (SCoh), which exploit the second-order cyclostationarity of vibration signals, have been proven effective supplements to ES-based techniques [12,13,14,15,16,17]. The Enhanced Envelope Spectrum (EES), obtained by integrating SCoh over the entire frequency band, highlights modulation components but also introduces irrelevant frequency content, reducing diagnostic reliability under strong noise. To mitigate this, the Improved Envelope Spectrum (IES) confines integration to an OFB. Mauricio et al. [18] proposed the Improved Envelope Spectrum via Feature Optimisation-gram (IESFOgram), which divides the frequency spectrum into a 1/3-octave binary tree and identifies OFBs based on fault characteristic frequencies (FCFs), achieving strong performance across diverse operating conditions [19,20,21,22]. Chen et al. [23] further refined OFB selection using FCF-guided analysis, while Zhang et al. [24] developed a weighted SCoh-based envelope spectrum for improved fault detection. Similarly, to mitigate the influence of non-Gaussian noise and interfering cyclic frequencies, Cheng et al. [25] proposed an enhanced spectral coherence method by cascading median filtering and the autocorrelation function, effectively highlighting the second-order cyclostationary features of bearing faults. Although statistically optimized band-selection methods can enhance feature energy concentration, their performance strongly depends on signal quality. In practice, weak early fault impulses are often masked by dominant vibration sources or noise, leading to inaccurate OFB selection. To address this issue, nonlinear preprocessing before demodulation can strengthen weak fault features and suppress interference. In this context, Spectral Amplitude Modulation (SAM) offers a promising solution for amplifying subtle fault impulses and improving feature extraction robustness [26]. Building on this, recent advancements have further refined the technique. For instance, Jiang et al. [27] proposed a Time-Frequency Spectral Amplitude Modulation (TFSAM) method, which employs a SAM-like strategy integrated with unbiased autocorrelation and information entropy to adaptively select the optimal magnitude order. While this method effectively optimizes signal reconstruction parameters, diagnostic performance can be further enhanced by explicitly identifying the OFB to precisely isolate fault resonance regions.
Furthermore, while the PESOgram proposed by Chen et al. [28] enhances diagnostic robustness through generalized envelope spectrum fusion, the IESCFFOgram introduced by Cheng et al. [29] utilizes candidate fault frequencies to adaptively identify informative bands, effectively mitigating the reliance on single statistical indicators. Distinct from these approaches, the proposed SAM-TSHOgram uniquely integrates nonlinear signal preprocessing (SAM) to amplify weak impulses with a two-stage hierarchical evaluation strategy. This composite approach explicitly quantifies both periodic correlation and spectral sparsity, ensuring precise feature extraction even under heavy noise conditions.
To rigorously validate the proposed method, a comparative analysis was conducted using three representative techniques. First, the EES is selected as the theoretical baseline for cyclostationary analysis, acknowledged for revealing hidden periodicities, though often constrained by full-band noise integration. Second, the FK is included as the widely cited industry standard due to its automation and efficiency, despite its known sensitivity to non-Gaussian interference. Finally, IESFOgram, serving as a benchmark for more advanced optimization strategies, represents a highly accurate band selection method. However, it still relies on idealized assumptions (such as the absence of bearing slip). This hierarchical selection—ranging from traditional baselines to advanced algorithms—highlights the specific contributions of the proposed SAM-TSHOgram in addressing the limitations of existing frameworks.
This study aims to address the following issues: (1) under strong noise and low SNR conditions, early fault features of rolling bearings are easily masked, making traditional envelope analysis and band selection methods ineffective for extracting weak periodic impacts; and (2) while advanced optimization strategies have been developed, many existing frequency band selection metrics still lack a unified assessment that simultaneously quantifies harmonic significance and energy sparsity, which can limit diagnostic robustness under complex interference. To overcome these challenges, this paper proposes a two-stage harmonic optimization-gram based on spectral amplitude modulation (SAM-TSHOgram) to improve fault feature extraction and diagnostic accuracy under complex operating conditions. The main innovations are as follows:
(1)
An adaptive SAM preprocessing strategy is employed, which automatically optimizes the weighting exponent to nonlinearly regulate spectral components and enhance weak fault features.
(2)
A composite evaluation model combining the autocorrelation-based Periodic Harmonic Correlation Strength (PHCS) and the spectral negentropy-based Sparse Harmonic Significance (SHS) is developed to comprehensively quantify the significance of fundamental and harmonic components.
(3)
Comparative experiments with EES, FK, and IESFOgram verify that the proposed method achieves superior SNR enhancement, suppression of spurious peaks, and clearer weak features, demonstrating higher diagnostic robustness and reliability.
The remainder of this paper is organized as follows: Section 2 introduces the theoretical background of spectral amplitude modulation and cyclostationary analysis for bearing fault signals, followed by the proposed methodology for the SAM-TSHOgram, including the two-stage evaluation strategy with PHCS and SHS metrics. Section 3 presents simulation results for an outer-race fault model, along with experimental validations using CWRU bearing and SEU gearbox datasets for various fault types, including comparative analyses and quantitative evaluations. Section 4 concludes the paper and outlines future research directions.

2. Theory and Methodology

This section presents the theoretical foundations and the specific methodology of the proposed study. First, the theoretical framework is outlined, covering three key components: the principles of SAM are introduced as a nonlinear filtering strategy to enhance weak fault features; the fundamentals of SCoh and the EES are detailed for exploiting second-order cyclostationarity; and the rationale behind the IES is discussed, highlighting the limitations of traditional OFB selection methods in noisy environments. Subsequently, based on these theories, the proposed SAM-TSHOgram methodology and its implementation steps are described in detail.

2.1. Spectral Amplitude Modulation

Spectral Amplitude Modulation (SAM) is a signal processing method based on nonlinear filtering principles, suitable for enhancing fault signatures in rotating machinery such as rolling bearings. This technique modulates the amplitude distribution of signals in the frequency domain to investigate the correspondence between spectral components at different energy levels and their envelope modulation characteristics.
Let the original vibration signal be x ( t ) , whose Fourier transform can be expressed as:
X f = X f e j ϕ f ,
where X f and ϕ f represent the amplitude spectrum and phase spectrum of the signal, respectively.
SAM introduces a magnitude order (MO) parameter p to construct a series of modified signals in the frequency domain as follows:
X p f = X f p e j ϕ f .
The corresponding time-domain signal is then obtained by the inverse Fourier transform (IFT):
x p t = I F T X p f .
The modified signal x p t is reconstructed from the modified amplitude and the actual phase. The lower and upper bounds of the MO recommended in this study are −0.5 and 2, respectively, enabling spectrum reconstruction to different extents. When p   =   0 , it corresponds to the cepstrum prewhitening (CPW) signal, whereas p   =   1 represents the original signal. The value of MO reflects the energy redistribution characteristics of the frequency components: when p   >   1 , high-amplitude components are further amplified while weak components are suppressed, thereby offering denoising capabilities; when 0   <   p   <   1 , both high- and low-amplitude components are preserved to a certain extent; when p   <   0 , strong dominant frequency components are attenuated, making it suitable for highlighting low-energy weak impact signals. Therefore, appropriately selecting the MO can effectively enhance periodic pulse features while suppressing noise interference.
Adaptive Selection of MO ( p ): To eliminate the subjectivity of manual parameter tuning, the proposed framework employs an adaptive optimization strategy. The SHS—which will be detailed in Section 2.4.2—is utilized as the objective function. The algorithm iterates the magnitude order p within the search range [−0.5, 2] with a step size of 0.1. Since the input signal spectrum varies with p , the resulting SHS metric is inherently a function of p . Let S H S m a x p denote the maximum SHS value obtained across all optimal frequency band candidates for a given p :
S H S m a x p = max f c , B w { S H S f c , B w p } ,
where S H S f c , B w p represents the SHS score of a specific band derived from the p -modulated signal. The optimal value p o p t is then automatically determined by finding the global maximum of these scores:
p o p t = a r g m a x p   ∈   [ − 0.5 , 2 ] S H S m a x p .
This ensures that the selected MO yields the most prominent fault features based on a consistent mathematical criterion.

2.2. Spectral Coherence and Enhanced Envelope Spectrum

Vibration signals from rolling bearings typically exhibit pronounced second-order cyclostationarity, meaning their instantaneous autocorrelation function varies periodically over time. This characteristic can be revealed through spectral analysis.
For a bearing fault signal x ( t ) exhibiting cyclostationarity, its instantaneous autocorrelation function R x t , τ is periodic with respect to time t , i.e., R x t , τ = R x t + T , τ , where T denotes the cyclic period of fault impacts, and τ represents the time lag. By applying a double Fourier transform to the autocorrelation function, the spectral correlation (SC) function S x α , f can be obtained [26]:
S x α , f = l i m W → ∞ 1 W E X W ∗ f X W f + α ,
where E { ⋅ } denotes the ensemble expectation, W is the analysis window length, and X W f represents the short-time Fourier transform (STFT) of the signal x ( t ) . Physically, the SC function S x α , f quantifies the degree of correlation between spectral components at frequencies f and f + α . Therefore, it maps a one-dimensional vibration signal onto a two-dimensional plane, where the f -axis corresponds to the carrier frequency, typically representing resonance bands of the system, while the α -axis corresponds to the cyclic frequency, which contains the modulation information related to FCFs and their harmonics.
For normalization and comparative analysis, the SCoh—a normalized form of SC—is commonly adopted and is defined as
γ x α , f = S x α , f S x 0 , f S x 0 , f + α ,
where S x 0 , f denotes the power spectral density (PSD) of the signal. The magnitude of SCoh is normalized within the range [0, 1], allowing clearer visualization of the signal’s cyclostationary characteristics.
A direct fault diagnosis approach based on the SCoh map is the computation of the EES, which integrates the magnitude of SCoh along the carrier frequency axis:
E E S ( α ) = 1 F s 2 ∫ 0 F s 2 | γ x ( α , f ) | d f .
Compared to the traditional ES, EES can better suppress noise and extract fault features [30]. However, as it integrates over the entire frequency band, strong background noise and interference from irrelevant frequency components are also incorporated. Under early-stage fault conditions or low SNR scenarios, weak fault information may be overwhelmed by these interferences, resulting in degraded diagnostic performance.

2.3. Improved Envelope Spectrum and Optimal Band Selection

To address the sensitivity of the EES to noise across the entire frequency band, integration solely within the OFB containing abundant fault information has been proposed, yielding the IES:
I E S ( α ) = 1 f 2 − f 1 ∫ f 1 f 2 | γ x ( α , f ) | d f ,
where f 1 , f 2 denotes the selected OFB. Clearly, the diagnostic performance of IES is highly dependent on the accuracy of OFB selection. If the frequency band is improperly chosen, the performance of IES may even deteriorate compared to that of EES.
Existing methods, such as the IESFOgram, typically involve the division of the frequency domain into subbands using filter banks (e.g., 1/3-octave binary trees), followed by the evaluation of each subband based on specific metrics, with the subband exhibiting the highest metric value being selected as the OFB. Although feature energy concentration is theoretically enhanced by such approaches, robustness against noise is often lacking due to the reliance on a single statistical feature under low SNR or weak fault conditions. Therefore, fault pulses can be enhanced and interference suppressed through nonlinear methods prior to band selection and demodulation analysis, thereby improving the accuracy of subsequent band selection. More stable input is also provided for the construction of the IES based on SCoh, enabling adaptive identification of the OFB.

2.4. Methodology

To overcome the shortcomings of existing metrics in feature characterization and to enhance noise immunity, a composite evaluation strategy was designed. This strategy employs a two-stage assessment process, focusing, respectively, on the periodic correlation structure and harmonic sparsity characteristics of the signal. The results from both stages are then combined to make an optimal decision.

2.4.1. Stage I: Coarse Band Screening

The objective of the first stage is to identify the frequency bands exhibiting the strongest periodic structure and correlation among all candidate IES, specifically by amplifying periodic components using the autocorrelation function.
For each candidate IES, its autocorrelation function (AIES) [31] is computed as:
A I E S η = E I E S α ⋅ I E S α + η ,
where η denotes the cyclic frequency lag. To quantify the periodic intensity, the Periodic Harmonic Correlation Strength (PHCS) is constructed in the cyclic frequency lag domain ( η ). The input argument is the magnitude of the improved envelope spectrum, I E S α . The PHCS metric is defined as
P H C S f c , B w = ∑ k = 1 K max η ∈ Ω k { A I E S η } A I E S 0 − max k ∈ { 1 … K } { max η ∈ Ω k { A I E S η } } ,
where K denotes the number of harmonics considered, A I E S ( 0 ) represents the total signal energy, and Ω k refers to a small window centered around the cyclic lag k ⋅ α f . The numerator of PHCS corresponds to the energy of the target periodic fault components, while the normalization term in the denominator, A I E S 0 − max { · } , represents the residual background energy after subtracting the dominant periodic energy. Therefore, PHCS functionally serves as a SNR indicator specifically designed for measuring the periodic strength of a signal. A higher PHCS value indicates that the frequency band exhibits a more pronounced periodic structure consistent with the theoretical fault model.
All frequency bands are sorted in descending order according to their PHCS values. The top 10% bands with the highest PHCS are selected as high-quality candidates for the next stage of fine selection.

2.4.2. Stage II: Fine Band Selection

The second stage aims to further refine the high-quality candidate set by selecting the frequency band with the most prominent and sparsely distributed harmonic peaks. This stage is inspired by the concept of spectral negentropy, which effectively measures the degree of energy concentration at specific frequency locations.
This stage operates in the cyclic-frequency domain ( α ) and takes the Improved Envelope Spectrum, I E S α , as its input. We then construct a Sparse Harmonic Significance (SHS) metric—a feature-guided measure inspired by the principle of negative entropy. Fundamentally, SHS acts as a sparsity indicator for evaluating the significance of fault harmonics. In contrast to standard spectral entropy, which evaluates global disorder over a normalized distribution, SHS specifically quantifies the localized energy concentration at the fault-related harmonic frequencies. A larger SHS value indicates that the harmonic peaks stand out more sharply against the average background noise, reflecting a state of higher spectral sparsity and a more prominent fault signature:
S H S f c , B w = 1 K ∑ k = 1 K I E S k α f 2 I E S α 2 ln I E S k α f 2 I E S α 2 ,
where I E S k α f 2 I E S α 2 represents the normalized energy probability of the k-th harmonic. Here, the normalization term ⟨ ( I E S ( α ) ) 2 ⟩ is the mean spectral energy across the selected band. This normalization scales the harmonic energy relative to the average noise floor, ensuring the metric highlights peaks with high statistical significance. The SHS index is highly sensitive to sharp energy peaks located at harmonic frequencies k α f . A larger SHS value implies that the harmonic components stand out more significantly relative to the average energy level of the band, reflecting a higher SNR and greater spectral sparsity.
Finally, for each frequency band within the Stage I candidate set, the SHS value is calculated, and the band yielding the maximum SHS is selected as the OFB.
It should be noted that while blind source indicators are generally effective for anomaly detection, their performance may become limited in complex tribological systems, particularly when non-fault impulsive components exhibit greater sparsity than early-stage bearing faults. Therefore, the SHS proposed in this paper is deliberately designed as a feature-oriented metric. This targeted design, together with the first-stage PHCS, ensures that the selected frequency band exhibits both correct cyclic periodicity and high spectral clarity, thereby reducing interference from non-fault sparse components.

2.4.3. Algorithmic Implementation Procedure

The complete implementation process of the SAM-TSHOgram method is shown in Figure 1:
Figure 1. The overall flowchart of the proposed SAM-TSHOgram method.
(1)
Signal Acquisition: Collect the vibration acceleration signal of the bearing.
(2)
Spectral Amplitude Modulation: By performing iterative searches within the candidate range, parameters that maximize the SHS metric are identified, thereby automatically determining the optimal modulation order and employing it as a preprocessing strategy.
(3)
SCoh Computation: As described in Section 2.2, compute the SCoh to transform the vibration signal into a bivariate representation with spectral and cyclic frequencies.
(4)
Filter Bank Decomposition: Decompose the SCoh map along the spectral frequency axis using a 1/3-octave binary filter bank, dividing the spectrum into multiple narrow sub-bands, each defined by a center frequency f c and bandwidth B w .
(5)
Stage I Evaluation: For each sub-band-derived IES, compute the correlated harmonic energy index P H C S . Rank all bands based on P H C S values, and select the top 10% as the candidate set.
(6)
Stage II Evaluation: Compute the sparse harmonic energy index SHS only for the bands in the candidate set.
(7)
SAM-TSHOgram Construction: Assign each computed SHS value to its corresponding frequency band to construct a composite map, referred to as the SAM-TSHOgram, thereby forming a feature library S H S ( f c , B w ) . The band with the highest SHS value is identified as the OFB:
O F B = a r g m a x f c , B w S H S f c , B w .
(8)
Final IES Generation: Integrate the SCoh map along the spectral frequency axis within the adaptively selected OFB to obtain the final IES for robust fault diagnosis.

3. Simulation and Experimentation

3.1. Simulation

In this section, simulation experiments are conducted to verify the capability of the proposed SAM-TSHOgram in OFB selection. For comparison, the IES based on SCoh is evaluated alongside the EES, the SES based on the FK, and the IES derived from the IESFOgram method.

3.1.1. Outer Race Fault Signal Model and Parameters

A numerically synthesized bearing vibration signal with an outer-race defect is generated according to the following model [31]:
x t = s t + n t = ∑ i A i ⋅ h t − t i + n t
where s ( t ) simulates a periodic impulse sequence produced by localized faults, n ( t ) is additive Gaussian white noise, and h ( t ) denotes the impulse response of the bearing–sensor transmission path, modeled as a decaying cosine function:
h t = e − β t cos 2 π f n t
Here, f n is the system’s natural (resonant) frequency, and β is the damping coefficient.
The amplitude A i of the i t h impulse varies periodically with the shaft rotation frequency f r , reflecting load modulation, and includes a small random perturbation term:
A i = A 0 1 + A m cos 2 π f r t i ⋅ J i
where A 0 is the base amplitude, A m is the modulation depth, and J i is a weak random factor with a mean of 1 to simulate stochastic fluctuations.
The actual occurrence time of the i t h impact, t i , is given by:
t i = i FCF + τ i
where FCF denotes the fault characteristic frequency. The term τ i represents a smooth random slip component generated by low-pass filtering a Gaussian white noise sequence through a moving-average operator. This design emulates the slow shaft-speed drifts caused by operational fluctuations in practical bearing systems.
Finally, according to a specified SNR, Gaussian white noise n ( t ) is added to the clean fault signal s ( t ) to obtain the final simulated signal x ( t ) .

3.1.2. Simulation Results and Comparative Analysis

Table 1 summarizes the simulation parameters, with the FCF set to 100 Hz. The simulated vibration waveform is shown in Figure 2, where the signal is contaminated by noise with an SNR of −22 dB.
Table 1. Parameter list for simulation model.
Figure 2. Waveform of simulated signal.
Figure 3 presents the conventional ES, in which the FCF and its harmonics are barely distinguishable. Figure 4a shows the SCoh of the simulated signal, where the periodic components induced by the fault are difficult to identify visually due to the heavy noise contamination. In Figure 4b, the EES still fails to reveal clear fault information. This failure primarily stems from the inherent mechanism of the EES, which performs spectral integration across the entire Nyquist bandwidth. Under such low SNR conditions (−22 dB), this full-band integration indiscriminately accumulates high-energy background noise along with the weak fault impulses. Consequently, the diagnostic features are completely submerged by the interference of dense spurious spectral lines, rendering the method ineffective.
Figure 3. Envelope spectrum.
Figure 4. Analysis results of the traditional EES method: (a) SCoh map blurred by noise; (b) EES where fault features are submerged by dense interference.
To verify the effectiveness of the proposed approach, the SAM-TSHOgram was first applied to the original signal without amplitude modulation preprocessing (i.e., MO = 1). As shown in Figure 5a, the SAM-TSHOgram exhibits multiple frequency bands with relatively high SHS values, indicating the presence of several potential candidate bands. The band corresponding to the maximum SHS value (Fc = 7917 Hz) was selected to generate the IES, as illustrated in Figure 5b. Although the FCF (100 Hz) and its harmonics can be observed, their amplitudes remain relatively low and are still partially affected by noise interference.
Figure 5. Analysis results of the TSHOgram without SAM enhancement (MO = 1): (a) Feature map shows Fc = 7917 Hz; (b) IES showing visible but weak fault harmonics affected by residual noise.
Subsequently, the complete SAM-TSHOgram framework was implemented, starting with the automatic optimization process illustrated in Figure 6. The maximum SHS score was evaluated across candidate MO from −0.5 to 2, where the global maximum is attained at MO = 2. Accordingly, p = 2 is automatically identified as the optimal parameter. This result supports theoretical expectations that higher MO values ( p > 1 ) under low SNR conditions effectively suppress background noise while amplifying fault harmonics, thereby maximizing spectral sparsity. Upon applying this optimal parameter, the signal underwent the proposed two-stage screening process—sequentially filtered by PHCS and refined by SHS. The resulting SAM-TSHOgram is presented in Figure 7a. In this feature map, a single dominant frequency band is clearly distinguished at Fc = 7812 Hz, which aligns closely with the preset resonance frequency of 8000 Hz, validating the effectiveness of combining SAM preprocessing with composite indicators.
Figure 6. Automatic MO selection (−0.5 ≤ MO ≤ 2).
Figure 7. Analysis results of the proposed SAM-TSHOgram (MO = 2): (a) Feature map shows Fc = 7812 Hz; (b) IES displaying distinct fault harmonics and effective noise suppression.
The IES generated from this adaptively selected OFB is displayed in Figure 7b. Compared with Figure 5b (without SAM, MO = 1), the FCF and its harmonics in Figure 7b exhibit substantially higher amplitudes and much clearer spectral lines. Meanwhile, the background noise is greatly suppressed, resulting in a remarkable improvement in SNR. These results demonstrate that the proposed SAM-TSHOgram can effectively enhance weak fault features and achieve robust frequency-band selection for fault diagnosis under strong noise conditions.
To fairly evaluate the individual contributions of SAM preprocessing, the fault feature frequency was computed across the entire frequency bandwidth using the optimal MO-reconstructed time-domain signal’s SES ( p = 2.0 ), as shown in Figure 8. Compared to the final IES generated by the proposed SAM-TSHOgram (Figure 7b), the spectrum in Figure 8 still exhibits noticeable residual noise and interference components. This indicates that relying solely on MO-based correction via SAM is insufficient for achieving the highest SNR. Consequently, the proposed two-stage frequency band selection strategy is essential for isolating the OFB and filtering out residual background noise.
Figure 8. Analysis results of the signal reconstructed by SAM alone (MO = 2): The SES displays enhanced fault harmonics compared to EES, yet significant residual noise persists due to the absence of frequency band selection.
To further benchmark the proposed method, comparative analyses were conducted using the IESFOgram and FK on the same noisy signal.
The results from the IESFOgram are shown in Figure 9. The IESFOgram integrates an optimized frequency band identification process, offering improvements over earlier methods. While it does manage to highlight a frequency band with fault information (Figure 9a), the resulting IES (Figure 9b) still reveals clear limitations: the FCF at 100 Hz is visible but with much weaker amplitude compared to the proposed method (Figure 7b), and substantial background noise remains.
Figure 9. Analysis results of the IESFOgram method: (a) Feature map shows Fc = 7812 Hz; (b) IES where fault features are present but less prominent due to noise leakage.
In contrast, the FK performs poorly under these conditions, as seen in Figure 10. The kurtosis indicator in Figure 10a becomes highly unstable in the presence of strong Gaussian noise, which leads to the selection of an irrelevant frequency band. Consequently, the SES in Figure 10b is overwhelmed by noise, with no discernible fault harmonics.
Figure 10. Analysis results of the FK method: (a) Kurtogram indicating inaccurate band selection; (b) SES failing to reveal any valid fault information.
This comparison highlights that while IESFOgram offers some improvement over traditional EES, it lacks the noise suppression capability of SAM-TSHOgram. FK, on the other hand, proves ineffective in this low SNR scenario.

3.1.3. Quantitative Comparison

To strictly quantify the diagnostic performance across different methods, the diagnostic Signal-to-Noise Ratio ( S N R d ) was adopted as the evaluation metric. It is computed as the ratio of the cumulative energy at the FCF and its harmonics to the energy of the remaining noise components in the envelope spectrum.
Under the severe noise constraints simulated at an input SNR of −22 dB, the quantitative evaluation summarized in Table 2 establishes a clear performance hierarchy. While traditional techniques struggled to penetrate the noise floor—exemplified by the FK plummeting to −32.97 dB and the conventional EES stagnating at −22.40 dB. However, the proposed SAM-TSHOgram demonstrates remarkable resilience, achieving a peak S N R d of −8.19 dB. This result provides justification for the architectural design within the proposed methodological framework; the complete SAM-TSHOgram yields an additional gain of approximately 5.57 dB over the standalone SAM preprocessing (MO = 2), a margin that underscores the critical necessity of the two-stage band selection strategy for filtering residual interference.
Table 2. S N R d Value comparison across different methods.

3.2. Experimentation

To further verify the effectiveness and generalizability of the proposed SAM-TSHOgram method in practical scenarios, this section presents experimental validations using the Case Western Reserve University (CWRU) bearing dataset and the Southeast University (SEU) gearbox dataset. Comparative analyses against established methods, such as IESFOgram and FK, are conducted across various fault types (including ball, inner race, and outer race faults) to evaluate the method’s diagnostic robustness and feature extraction capabilities under strong noise conditions.

3.2.1. Bearing Dataset

In this section, experimental validations were conducted using the CWRU benchmark dataset [32]. The test rig, illustrated in Figure 11, consists of a 2-horsepower Reliance Electric motor (Reliance Electric, Cleveland, OH, USA) and a dynamometer. The experiments focused on an SKF 6205-2RS JEM deep-groove ball (SKF, Gothenburg, Sweden) bearing featuring single-point defects with a diameter of 0.007 inches. To simulate realistic industrial conditions, a 2-HP load was applied, resulting in a shaft speed of approximately 1750 rpm. Vibration signals were acquired at sampling rates of 12 kHz for ball faults and 48 kHz for inner-race faults. Distinct from the additive white noise used in simulations, the interference in this setup is physically induced, originating primarily from electromechanical noise and structural resonances under the torque load. This configuration rigorously evaluates the method’s ability to extract weak fault features from real-world electromechanical background interference.
Figure 11. Experimental setup.
Case 1: Ball Fault (Defect Size 0.007 in)
The vibration waveform and the corresponding SCoh map are shown in Figure 12 and Figure 13a, respectively. As illustrated in Figure 12, no clear periodic impacts are observed in the time domain, and multiple discrete peaks appear in the frequency domain, indicating the potential presence of early-stage mechanical faults. In Figure 13a, the SCoh map also fails to reveal distinct fault-related features. The EES derived from SCoh, as shown in Figure 13c, exhibits weak amplitudes for the FCF and its harmonics, which are largely submerged among neighboring spectral lines.
Figure 12. Original Signal and Fourier Spectrum.
Figure 13. Comparative analysis results for the experimental ball fault signal: (a,c) The traditional SCoh and EES fail to reveal clear fault features due to heavy noise masking; (b,d) The proposed SAM-TSHOgram (MO = 1.9) accurately identifies the optimal band (Fc = 4031 Hz) and generates an IES with distinct FCFs.
SAM-TSHOgram analysis commenced with adaptive parameter optimization as shown in Figure 14. The algorithm automatically identified the optimal MO value of 1.9 corresponding to the maximum SHS. A weighting of p = 1.9 allows the nonlinear SAM process to effectively highlight high-energy transient impulses while attenuating the pervasive background noise, thereby creating a high-contrast input. Leveraging this improved signal-to-noise contrast, the subsequent two-stage evaluation strategy accurately filters out spectral interference, locking onto the optimal resonance band centered at Fc = 4031 Hz (Bw = 188 Hz) as displayed in Figure 13b. The effectiveness of this dual-layer approach is validated by the final IES in Figure 13d. In clear contrast to the noisy baselines, the fundamental ball fault frequency and its harmonics are rendered distinctly visible against a suppressed noise floor, demonstrating the method’s capability to overcome complex environmental interference.
Figure 14. Automatic MO selection (−0.5 ≤ MO ≤ 2).
The IESFOgram (Figure 15) does pick out a potential resonance band. However, when we look at the IES in Figure 15b, noise suppression remains quite limited. The FCF is still discernible, but the harmonic amplitudes come out rather weak and are partly masked by a relatively high noise floor. This naturally lowers the confidence in the diagnosis.
Figure 15. Analysis results of the IESFOgram method: (a) Feature map shows Fc = 2844 Hz; (b) IES where fault signatures are visible but compromised by significant background noise.
The FK, on the other hand, struggles considerably in this case (Figure 16). The kurtogram itself (Figure 16a) shows that the spectral kurtosis values are strongly affected by the background noise, which ends up guiding the algorithm toward a suboptimal frequency band. As a result, the SES in Figure 16b is completely dominated by random interference, making the fault features essentially undetectable.
Figure 16. Analysis results of the FK method: (a) Kurtogram indicating the selected frequency band; (b) SES dominated by noise, failing to identify valid fault features.
Case 2: Inner-Race Fault (Defect Size 0.007 in)
Figure 17 presents the original vibration signal and its Fourier spectrum. In the time domain, no obvious periodic impacts can be distinguished due to noise contamination, and the frequency-domain spectrum appears broadband and dominated by high-frequency components, with fault signatures largely masked. The SCoh map in Figure 18a also fails to extract any meaningful fault-related modulation information. The EES obtained from full-band integration, shown in Figure 18c, is filled with dense interfering spectral lines, making it difficult to observe the theoretical FCF and its harmonics.
Figure 17. Original signal and Fourier spectrum.
Figure 18. Comparative analysis results for the inner-race fault signal: (a,c) Traditional SCoh and EES are overwhelmed by dense spectral interference, failing to reveal fault patterns; (b,d) The proposed SAM-TSHOgram (MO = 1.5) accurately identifies the optimal band (Fc = 1125 Hz) and generates an IES with distinct FCFs.
The inner-ring fault diagnosis process of SAM-TSHOgram begins with the automatic optimization mechanism shown in Figure 19, which iteratively searches for the optimal MO of 1.5 corresponding to the maximum SHS. It strongly amplifies the repetitive impulsive signatures from the inner-race defect while effectively suppressing the broadband background noise. With this improved signal quality as a foundation, the two-stage evaluation strategy proves particularly valuable—by simultaneously considering periodic correlation and spectral sparsity, it successfully eliminates remaining interference and pinpoints the most informative resonance region. As seen in the SAM-TSHOgram map (Figure 18b), a clear OFB emerges, centered at Fc = 1125 Hz with a bandwidth of Bw = 750 Hz. The final IES extracted from this band (Figure 18d) is notably clean: in contrast to the heavily cluttered conventional EES, the proposed approach substantially reduces the noise floor, making the fundamental fault frequency and its higher-order harmonics stand out sharply with strong, well-defined amplitude peaks.
Figure 19. Automatic MO selection (−0.5 ≤ MO ≤ 2).
The IESFOgram (Figure 20) does try to select an informative frequency band, but its overall performance remains limited in this noisy case. Looking at the IES in Figure 20b, the fault harmonics are largely drowned out by dense spectral clutter. The background noise stays quite high, leading to a low diagnostic SNR that makes reliable fault identification rather challenging.
Figure 20. Analysis results of the IESFOgram method: (a) Feature map shows Fc = 375 Hz; (b) IES where fault harmonics are indistinct and cluttered by significant residual noise.
The FK, by comparison, fails completely in this complex noise environment (Figure 21). The spectral kurtosis metric proves highly unstable under the non-Gaussian interference, which results in the selection of a noise-dominated band (Figure 21a). As a result, the SES in Figure 21b shows no recognizable fault patterns at all.
Figure 21. Analysis results of the FK method: (a) Kurtogram indicating inaccurate band selection due to noise influence; (b) SES dominated by random peaks, failing to detect any fault information.

3.2.2. Gearbox Dataset

To further verify the generalizability of the proposed method under complex transmission conditions, experiments were conducted using the gearbox dataset provided by SEU. The data were collected from a Drivetrain Dynamic Simulator (DDS), the detailed configuration of which is illustrated in Figure 22 [33]. As shown in the setup, the test rig represents a comprehensive mechanical transmission system primarily composed of an induction motor serving as the power source, a motor speed controller, a two-stage gear transmission system, and a magnetic powder brake regulated by a brake controller to apply external loads. During the experiment, vibration signals were recorded at an operating speed of 1800 rpm and a sampling frequency of 12 kHz, with a load configuration of 2 V (7.32 N/m). Under this operating condition, the shaft rotational frequency is 30 Hz, and the corresponding outer-race FCF of the bearing is theoretically located at approximately 70 Hz. To simulate realistic industrial working conditions characterized by strong noise interference, the experiment relied on the inherent mechanical dynamics of the multi-stage gearbox system.
Figure 22. Experimental setup for the gearbox dataset.
Figure 23 shows the original gearbox vibration signal and its Fourier spectrum. The waveform exhibits complex dynamics without clear periodic impacts, and the frequency spectrum is broadband, preventing identification of sparse regions or fault-related harmonics. The SCoh map in Figure 24a reveals that the modulation information associated with the fault is completely masked by noise. The EES obtained from full-band integration (Figure 24c) displays dense interfering spectral lines and a low SNR, making it difficult to recognize the FCF.
Figure 23. Original signal and Fourier spectrum.
Figure 24. Comparative analysis results for the gearbox outer-race fault: (a,c) Traditional SCoh and EES are masked by broadband noise, failing to detect fault signatures; (b,d) The proposed SAM-TSHOgram (MO = 2.0) accurately identifies the optimal band (Fc = 94 Hz) and generates an IES with distinct FCFs.
The outer-ring fault diagnosis process of SAM-TSHOgram begins with the automatic optimization mechanism shown in Figure 25, which iteratively searches for the optimal MO of 2 corresponding to the maximum SHS. By applying a weighting of p = 2.0 , the nonlinear preprocessing aggressively suppresses the broadband background noise while preserving the strength of the fault impacts. This created a cleaner foundation for the subsequent analysis. With the noise interference significantly reduced, the two-stage evaluation strategy was able to distinguish the true fault features from random vibrations, pinpointing the frequency band centered at Fc = 125 Hz (Bw = 250 Hz) as shown in Figure 24b. The benefit of this combined approach is evident in the final IES (Figure 24d). The spectrum exhibits a minimal noise floor, allowing the outer-race fault frequency and its harmonics to appear clearly and distinctively, ensuring they are not mistaken for other mechanical components.
Figure 25. Automatic MO selection (−0.5 ≤ MO ≤ 2).
As displayed in Figure 26, the IESFOgram proves to be a competitive method for this dataset. The feature map successfully locates the resonance region, and the resulting spectrum in Figure 26b presents a recognizable fault pattern where the characteristic frequency and its harmonics are clearly visible. However, a close inspection reveals that the peak amplitudes are slightly lower than those achieved by the proposed method. In contrast, the FK shown in Figure 27 struggles significantly. The kurtosis-based selection fails to adapt to the complex gearbox vibrations, resulting in a spectrum dominated by random noise peaks where no fault features can be discerned.
Figure 26. Analysis results of the IESFOgram method: (a) Feature map shows Fc = 94 Hz; (b) IES can also clearly identify fault frequencies, but with lower amplitudes.
Figure 27. Analysis results of the FK method: (a) Kurtogram failing to locate the resonance band due to noise interference; (b) SES dominated by random peaks, resulting in a failure to identify the fault.

3.2.3. Quantitative Comparison

To ascertain whether the superiority observed in simulations translates to physical fault scenarios, Table 3 extends the comparative analysis to experimental datasets. Mirroring the simulation trends, the proposed method maintains a consistent performance edge across all fault types. Specifically, regarding the gearbox outer-race fault, although visual comparisons might suggest a close performance between IESFOgram and the proposed method, the quantitative metrics reveal a significant disparity. The SAM-TSHOgram achieves a diagnostic SNR of 2.63 dB, surpassing the IESFOgram (−1.12 dB) by nearly 4 dB. This quantitative lead confirms that the proposed method provides superior feature extractability and background noise suppression, even when spectral patterns appear visually similar.
Table 3. Comparison of S N R d for different fault types.

3.3. Discussion

The performance differences observed in experimental results and quantitative analysis can be attributed to the distinct signal processing mechanisms employed by each method. The traditional EES relies on full-band integration, which tends to accumulate background noise alongside fault components, thereby limiting its sensitivity under low SNR conditions. The FK targets impulsive features; however, because spectral kurtosis primarily quantifies signal sparsity rather than periodicity, it may inadvertently highlight non-fault random impulses that exhibit high sparsity but lack cyclic structure. This limitation likely contributes to the inaccurate band selection observed in the experimental cases. Similarly, although the IESFOgram improves band selection, its dependence on ideal operating assumptions (e.g., no slip) and susceptibility to spectral interference frequently limit its ability to isolate fault-sensitive regions in complex industrial environments.
In contrast, the proposed SAM-TSHOgram mitigates these risks through a hierarchical strategy. The initial nonlinear SAM preprocessing enhances the contrast between high-energy transients and the noise floor. Crucially, the subsequent two-stage evaluation differentiates fault features from interference: the Stage I PHCS metric, based on autocorrelation, prioritizes components with cyclic correlation, effectively filtering out random, non-periodic impulses that might mislead sparsity-based indicators. The Stage II SHS metric then refines the selection by focusing on spectral sparsity. This combined approach allows the method to robustly identify the informative frequency band, ensuring reliable fault detection even in the presence of heavy noise or spurious impulsive interference.

4. Conclusions

To address the challenge of effectively extracting early fault features in rolling bearings, an adaptive IES method based on spectral amplitude modulation—SAM-TSHOgram—has been proposed for the adaptive identification of the OFB. Within the IES framework, SAM and a composite indicator evaluation mode have been incorporated. Impact components are enhanced by SAM, while nonlinear noise is suppressed. By combining PHCS and SHS indicators, periodic fault information within frequency bands is effectively characterized. The spectral frequency axis is decomposed using a 1/3-octave binary tree filter bank, achieving refined frequency band division. Ultimately, the IES is constructed by integrating the SCoh within the OFB, enabling precise extraction of early fault features in rolling bearings.
Systematic validation of the proposed SAM-TSHOgram has been conducted using simulated signals and experimental data. Results indicate that the SNR and spectral line sparsity of the IES are significantly enhanced by this method under strong noise conditions. Compared with other traditional methods, the FCF and its harmonics are more accurately identified. Consequently, the proposed method exhibits superior robustness and diagnostic accuracy.
Despite some initial achievements, large-scale industrial deployment still faces challenges. In terms of application potential, this method exhibits strong resistance to both Gaussian and non-Gaussian noise, making it particularly suitable for heavy machinery operating in harsh environments where early fault characteristics are often obscured by intense mechanical interference. However, practical implementation faces two primary challenges. First, actual industrial equipment often operates under time-varying speeds and fluctuating loads. Since the current SCoh-based framework assumes cyclostationarity, future iterations must integrate order tracking or time-frequency analysis to accommodate non-stationary conditions. Second, while this study focused on single-point defects, industrial failures frequently manifest as compound faults.
Therefore, future research will focus on the application of SAM-TSHOgram in the diagnosis of composite bearing failures under complex variable-speed conditions, identifying this as a key area for further investigation.

Author Contributions

Conceptualization, Y.C.; Methodology, J.W.; Formal analysis, Q.D.; Writing—original draft, Q.F.; Writing—review & editing, Q.F.; Funding acquisition, J.H., L.W. and R.Q. All authors have read and agreed to the published version of the manuscript.

Funding

National Natural Science Foundation of China (61175054); Natural Science Foundation of Zhejiang Province (LY16E050001); Cixi City Science and Technology Project (2023CXS080009).

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.

Conflicts of Interest

Authors Jiqiang Hu, Linqiang Wu and Rui Qin were employed by the company Ningbo Donghuang Bearing Co., Ltd. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

  1. Randall, R.B.; Antoni, J. Rolling Element Bearing Diagnostics—A Tutorial. Mech. Syst. Signal Process. 2011, 25, 485–520. [Google Scholar] [CrossRef] [Scilit]
  2. Tiwari, P.; Upadhyay, S.H. Novel Self-Adaptive Vibration Signal Analysis: Concealed Component Decomposition and Its Application in Bearing Fault Diagnosis. J. Sound Vib. 2021, 502, 116079. [Google Scholar] [CrossRef] [Scilit]
  3. Li, Q.; Chen, B.; Zhang, W.; Song, D. Research on Mathematical Morphological Operators for Fault Diagnosis of Rolling Element Bearings. Measurement 2022, 203, 111964. [Google Scholar] [CrossRef] [Scilit]
  4. Lei, Y.; Li, N.; Guo, L.; Lin, J.; Yan, T.; Li, N. Machinery Health Prognostics: A Systematic Review from Data Acquisition to RUL Prediction. Mech. Syst. Signal Process. 2018, 104, 799–834. [Google Scholar] [CrossRef] [Scilit]
  5. Antoni, J.; Randall, R.B. The Spectral Kurtosis: Application to the Vibratory Surveillance and Diagnostics of Rotating Machines. Mech. Syst. Signal Process. 2006, 20, 308–331. [Google Scholar] [CrossRef] [Scilit]
  6. Antoni, J. The Spectral Kurtosis: A Useful Tool for Characterising Non-Stationary Signals. Mech. Syst. Signal Process. 2006, 20, 282–307. [Google Scholar] [CrossRef] [Scilit]
  7. Antoni, J. Fast Computation of the Kurtogram for the Detection of Transient Faults. Mech. Syst. Signal Process. 2007, 21, 108–124. [Google Scholar] [CrossRef] [Scilit]
  8. Tang, G.; Tian, T. Compound Fault Diagnosis of Rolling Bearing Based on Singular Negentropy Difference Spectrum and Integrated Fast Spectral Correlation. Entropy 2020, 22, 367. [Google Scholar] [CrossRef] [Scilit]
  9. Zhang, K.; Xu, Y.; Liao, Z.; Song, L.; Chen, P. A Novel Fast Entrogram and Its Applications in Rolling Bearing Fault Diagnosis. Mech. Syst. Signal Process. 2021, 154, 107582. [Google Scholar] [CrossRef] [Scilit]
  10. Chen, B.; Song, D.; Cheng, Y.; Zhang, W.; Huang, B.; Muhamedsalih, Y. IGIgram: An Improved Gini Index-Based Envelope Analysis for Rolling Bearing Fault Diagnosis. J. Dyn. Monit. Diagn. 2022, 1, 111–124. [Google Scholar] [CrossRef] [Scilit]
  11. Moshrefzadeh, A.; Fasana, A.; Garibaldi, L. Using Unbiased Autocorrelation to Enhance Kurtogram and Envelope Analysis Results for Rolling Element Bearing Diagnostics. In Proceedings of the 9th International Conference on Surveillance (SURV’17), Vandoeuvre-lès-Nancy, France, 29–30 May 2017. [Google Scholar]
  12. Abboud, D.; Antoni, J.; Eltabach, M.; Sieg-Zieba, S. Angle/Time Cyclostationarity for the Analysis of Rolling Element Bearing Vibrations. Measurement 2015, 75, 29–39. [Google Scholar]
  13. Chen, X.; Guo, Y.; Na, J. Proportional Selection Scheme: A Frequency Band Division Tool for Rolling Element Bearing Diagnostics. IEEE Trans. Ind. Electron. 2021, 69, 9504–9513. [Google Scholar] [CrossRef] [Scilit]
  14. Randall, R.B.; Antoni, J.; Chobsaard, S. The Relationship between Spectral Correlation and Envelope Analysis in the Diagnostics of Bearing Faults and Other Cyclostationary Machine Signals. Mech. Syst. Signal Process. 2001, 15, 945–962. [Google Scholar] [CrossRef] [Scilit]
  15. Wodecki, J.; Michalak, A.; Wyłomańska, A.; Zimroz, R. Influence of Non-Gaussian Noise on the Effectiveness of Cyclostationary Analysis—Simulations and Real Data Analysis. Measurement 2021, 171, 108814. [Google Scholar] [CrossRef] [Scilit]
  16. Schmidt, S.; Heyns, P.S.; Gryllias, K.C. A Methodology Using the Spectral Coherence and Healthy Historical Data to Perform Gearbox Fault Diagnosis under Varying Operating Conditions. Appl. Acoust. 2020, 158, 107038. [Google Scholar] [CrossRef] [Scilit]
  17. Wang, H.; Li, C.; Du, W. Coupled Hidden Markov Fusion of Multichannel Fast Spectral Coherence Features for Intelligent Fault Diagnosis of Rolling Element Bearings. IEEE Trans. Instrum. Meas. 2021, 70, 1–10. [Google Scholar] [CrossRef] [Scilit]
  18. Mauricio, A.; Smith, W.A.; Randall, R.B.; Antoni, J.; Gryllias, K. Improved Envelope Spectrum via Feature Optimisation-Gram (IESFOgram): A Novel Tool for Rolling Element Bearing Diagnostics under Non-Stationary Operating Conditions. Mech. Syst. Signal Process. 2020, 144, 106891. [Google Scholar] [CrossRef] [Scilit]
  19. Mauricio, A.; Sheng, S.; Gryllias, K. Condition Monitoring of Wind Turbine Planetary Gearboxes under Different Operating Conditions. J. Eng. Gas Turbines Power 2020, 142, 031003. [Google Scholar] [CrossRef] [Scilit]
  20. Mauricio, A.; Qi, J.; Gryllias, K. Vibration-Based Condition Monitoring of Wind Turbine Gearboxes Based on Cyclostationary Analysis. J. Eng. Gas Turbines Power 2019, 141, 031026. [Google Scholar]
  21. Mauricio, A.; Qi, J.; Smith, W.A.; Sarazin, M.; Randall, R.B.; Janssens, K.; Gryllias, K. Bearing Diagnostics under Strong Electromagnetic Interference Based on Integrated Spectral Coherence. Mech. Syst. Signal Process. 2020, 140, 106673. [Google Scholar] [CrossRef] [Scilit]
  22. Mauricio, A.; Gryllias, K. Cyclostationary-Based Multiband Envelope Spectra Extraction for Bearing Diagnostics: The Combined Improved Envelope Spectrum. Mech. Syst. Signal Process. 2021, 149, 107150. [Google Scholar] [CrossRef] [Scilit]
  23. Chen, B.; Cheng, Y.; Zhang, W.; Gu, F.; Mei, G. Optimal Frequency Band Selection Using Blind and Targeted Features for Spectral Coherence-Based Bearing Diagnostics: A Comparative Study. ISA Trans. 2022, 127, 395–414. [Google Scholar] [CrossRef] [Scilit]
  24. Zhang, B.; Miao, Y.; Lin, J.; Gryllias, K.; Li, C. Weighted Envelope Spectrum Based on the Spectral Coherence for Bearing Diagnosis. ISA Trans. 2022, 123, 398–412. [Google Scholar] [CrossRef] [Scilit]
  25. Cheng, Y.; Chen, B.; Zhang, W. Enhanced Spectral Coherence and Its Application to Bearing Fault Diagnosis. Measurement 2022, 188, 110418. [Google Scholar] [CrossRef] [Scilit]
  26. Moshrefzadeh, A.; Fasana, A.; Antoni, J. The Spectral Amplitude Modulation: A Nonlinear Filtering Process for Diagnosis of Rolling Element Bearings. Mech. Syst. Signal Process. 2019, 132, 253–276. [Google Scholar] [CrossRef] [Scilit]
  27. Jiang, Z.; Zhang, K.; Xiang, L.; Yu, G.; Xu, Y. A Time-Frequency Spectral Amplitude Modulation Method and Its Applications in Rolling Bearing Fault Diagnosis. Mech. Syst. Signal Process. 2023, 185, 109832. [Google Scholar] [CrossRef] [Scilit]
  28. Chen, B.; Zhang, W.; Gu, J.X.; Song, D.; Cheng, Y.; Zhou, Z.; Gu, F.; Ball, A.D. Product Envelope Spectrum Optimization-gram: An Enhanced Envelope Analysis for Rolling Bearing Fault Diagnosis. Mech. Syst. Signal Process. 2023, 193, 110270. [Google Scholar] [CrossRef] [Scilit]
  29. Cheng, Y.; Wang, S.; Chen, B.; Mei, G.; Zhang, W.; Peng, H.; Tian, G. An Improved Envelope Spectrum via Candidate Fault Frequency Optimization-Gram for Bearing Fault Diagnosis. J. Sound Vib. 2022, 523, 116746. [Google Scholar] [CrossRef] [Scilit]
  30. Abboud, D.; Elbadaoui, M.; Smith, W.A.; Randall, R. Advanced Bearing Diagnostics: A Comparative Study of Two Powerful Approaches. Mech. Syst. Signal Process. 2019, 114, 604–627. [Google Scholar] [CrossRef] [Scilit]
  31. Cui, L.; Zhao, X.; Liu, D.; Wang, H. A spectral coherence cyclic periodic index optimization-gram for bearing fault diagnosis. Measurement 2024, 224, 113898. [Google Scholar]
  32. Case Western Reserve University Bearing Data Center. Case Western Reserve University Bearing Data Center Website. Available online: https://engineering.case.edu/bearingdatacenter (accessed on 8 June 2025).
  33. Shao, S.; McAleer, S.; Yan, R.; Baldi, P. Highly Accurate Machine Fault Diagnosis Using Deep Transfer Learning. IEEE Trans. Ind. Inf. 2018, 15, 2446–2455. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.