Shaking Table Tests on the Seismic Response of Symmetrically Integrated Underground Stations

,
and
Key Laboratory of Urban Security and Disaster Engineering of Education, Beijing University of Technology, Beijing 100124, China
*
Author to whom correspondence should be addressed.

Abstract

This paper focuses on the seismic response of symmetrical underground subway stations to seismic waves with varying frequencies and peak ground accelerations (PGAs), essential in light of growing urban underground transit systems. A 1/40 scale station model was subjected to seismic simulations using waves from the Wenchuan and Tangshan earthquakes and an artificial wave spanning 0.1 g to 0.5 g PGAs. Shaking table tests revealed that seismic impacts divide at PGA = 0.3 g; high-frequency waves affect structures more below this threshold, while low-frequency waves have more impact above it. The columns on the third basement level responded more to seismic activity, particularly at their base. The study recommends prioritizing the seismic design of these columns during station construction, especially in earthquake-prone zones. Understanding the dynamic effects of different frequencies and amplitudes is crucial for selecting and reinforcing materials and structural designs to enhance seismic resistance.