Skip to Content
WaterWater
  • Article
  • Open Access

27 November 2026

17 Pages

Effects of Averaging Duration and Index-Velocity Calibration Strategy on Low-Velocity H-ADCP Discharge Estimation in a Compound Channel

,
,
and
1
Research Strategic Planning Department, Korea Institute of Civil Engineering and Building Technology, 283, Goyangdae-ro, Ilsanseo-gu, Goyang-si 10223, Gyeonggi-do, Republic of Korea
2
River Experiment Center, Korea Institute of Civil Engineering and Building Technology, 942, Agok-gil, Andong-si 36754, Gyeongsangbuk-do, Republic of Korea
*
Author to whom correspondence should be addressed.
This article belongs to the Section Hydraulics and Hydrodynamics

Abstract

Horizontal acoustic Doppler current profilers (H-ADCPs) combined with the index-velocity method (IVM) are widely used for discharge monitoring, but the joint effects of averaging duration, index-cell selection, rating estimation, calibration range and stage reference on low-velocity IVM discharge remain unexamined under controlled conditions. We operated an SL-500 at floodplain elevation and an SL-1500 in the main channel of a compound experimental channel under three steady flows (mean velocity of 0.077–0.181 m/s). Within the ≈2000 s records, the standard deviation of single index-velocity averages decreased approximately as 1/√m. Because this absolute temporal standard deviation was nearly constant (≈0.023 m/s for 60 s averages), the estimated averaging duration required for a coefficient of variation (standard deviation relative to the mean) of 5% increased from ≈270 to ≈1640 s as velocity decreased. Ordinary least squares on 60 s blocks underestimated the rating slope by ≈17% through regression dilution, and Deming regression gave a slope close to the condition-mean value. Leave-one-condition-out errors were ≈±2% for interpolation and high-velocity extrapolation but +15–18% below the calibration range. The main-channel SL-1500 was more precise but failed when extrapolated. A 7.5–9.7 cm stage discrepancy between sensors produced a ≈10% wetted-area difference. Temporal precision, spatial representativeness, calibration-range coverage and stage consistency govern low-velocity IVM performance.

1. Introduction

Continuous streamflow records underpin flood forecasting, water resources management and the operation of hydraulic structures. Stage–discharge ratings lose accuracy where backwater or bed changes occur, so index-velocity methods (IVMs) based on side-looking, horizontally deployed acoustic Doppler current profilers (H-ADCPs) have become a widely used alternative [1,2,3,4]. An IVM regresses a reference cross-sectional mean velocity, usually obtained from moving-boat acoustic Doppler current profilers (ADCP) measurements, on an index velocity measured by the H-ADCP, and multiplies the rated mean velocity by the wetted area derived from a stage–area relation [2]. Because a systematic offset that is stable across conditions is absorbed into the rating coefficients, IVM performance depends less on the absolute accuracy of the index velocity than on its repeatability, the stability of the index–mean velocity relation across conditions, and the hydraulic range represented by the calibration data.
Low velocities are where these premises are most easily violated. H-ADCP velocities are affected by flow disturbance near the instrument [5,6], by signal attenuation and surface or bed reflections in the far field, and by sidewall effects [1,7]; Le Coz et al. [1] reported significant underestimation across the whole section when the mean velocity fell below about 0.4 m/s. Literature syntheses indicate that total discharge uncertainty may reach ±50–100% at low flows compared with ±10–20% at medium to high flows [8,9], and the variability of acoustic measurements becomes pronounced below about 0.25 m/s [10]. Sampling duration has repeatedly been identified as a key control on the uncertainty of acoustic velocity measurements [11,12].
The Guide to the Expression of Uncertainty in Measurement (GUM) [13] provides the general framework for evaluating measurement uncertainty, and it has been applied to streamflow measurements with acoustic Doppler velocimeters [14], to the decomposition of uncertainty sources in ADCP discharge measurements [15] and to the velocity–area method [16]. Nevertheless, the uncertainty of index-velocity ratings is still often summarized by goodness-of-fit statistics such as the coefficient of determination or the regression standard error [8]. We are not aware of a controlled, full-scale compound-channel study that jointly examines how (i) the precision of the index velocity as a function of averaging duration, (ii) the spatial selection of index cells, (iii) the rating estimator and calibration range, and (iv) the consistency of the stage that defines the wetted area propagate into the predicted discharge under low-velocity conditions.
The aim of this study is not to derive a rating transferable to a particular river, but to isolate, under controlled conditions, the effects of averaging duration, cell selection, rating estimation, calibration range and stage reference on IVM discharge prediction at low velocities. Using two H-ADCPs (SonTek SL-500 and SL-1500) in the compound experimental channel of the Korea Institute of Civil Engineering and Building Technology (KICT) River Experiment Center, we (1) quantify the precision of a single average as a function of averaging duration using non-overlapping batch means and Allan deviation and derive a target-precision rule for the averaging duration; (2) characterize the systematic offset of the SL-500 relative to collocated acoustic Doppler velocimeter (ADV) measurements and the geometric limitation of its boundary cell; (3) compare index-cell selection based on precision (coefficient of determination, R2) with selection based on transferability (leave-one-condition-out validation); (4) compare case-mean, block and Deming rating estimators to separate the role of the calibration range; and (5) verify the consistency of stage and wetted area between the two sensors and propose measurement guidelines for reliable low-velocity IVM discharge estimation.

2. Materials and Methods

2.1. Index-Velocity Method

An H-ADCP measures velocities in cells arranged along its horizontal beams at the deployment elevation; the mean of one or more cells is used as the index velocity, V. The IVM establishes a linear relation with the reference cross-sectional mean velocity, U (Equation (1)), and computes discharge using Equation (2) [2]:
U = a · V + b
Q = ( a · V + b ) · A ( h )
where A(h) is the wetted area at stage h. If the index velocity is related to the true mean velocity by V = α·U + β, the proportional and constant offsets are absorbed into the slope and intercept (Equation (3)). A condition-independent offset therefore leaves no error in IVM discharge, whereas a relation that changes non-linearly with conditions leaves residual error.
U = ( V − β ) / α , a = 1 / α , b = − β / α

2.2. Precision as a Function of Averaging Duration

The Type A standard uncertainty of the GUM [13], u = s/√n, assumes independent observations. When averaging windows are overlapped to keep the number of samples fixed for long averaging durations, the correlation between windows is created by the analysis design rather than by the flow. To avoid this artifact, the central 200 samples of each 10 s record were divided into non-overlapping blocks of m samples (T = 10 ms), and the standard deviation of the block means, ST, was taken as the Type A standard uncertainty of a single T-second average; its relative value, CVT = ST/ V ¯ , where V ¯ is the record-mean index velocity, is reported as the coefficient of variation (CV). Because ST is computed from the temporal scatter of block means within a steady record, it quantifies the random (Type A) variability of a single T-second average. It comprises both the random error of the instrument, including Doppler noise and the internal averaging of each 10 s sample, and real velocity fluctuations within the sampling volume, which cannot be separated with the present data. Systematic components that remain constant during a record—such as instrument bias, installation errors in alignment or elevation, and the offset relative to the ADV (Section 3.3)—do not contribute to ST; ST is therefore not the total measurement uncertainty of the index velocity. It was compared with the prediction for independent samples (Equation (4)), and the 95% confidence interval of ST was evaluated from the chi-square distribution. Each 10 s sample was assumed to be the instrument average over the full sampling interval.
S WN ( T ) = s 10 / √ m , ratio = s T / s WN
When the ratio is close to one, the uncertainty decreases as for independent samples, and the averaging duration needed for a target relative precision e follows from Equation (5). Low-frequency variability and drift at long time scales were diagnosed with the overlapping Allan deviation (Equation (6)) [17]. Because Korean discharge-measurement agencies average 1 s or 10 s data over 430 s, the precision corresponding to this operational averaging duration is also reported.
T req = 10 · ( C V 10 / e ) 2 [ s ]
σ y 2 ( τ ) = 1 2 · ⟨ ( ȳ ( k + 1 ) − ȳ k ) 2 ⟩

2.3. Rating Estimation and Validation

The 60 s block index velocity (33 blocks per condition) scatters strongly within each condition, so ordinary least squares (OLS) applied to all blocks underestimates the slope through regression dilution caused by errors in the predictor [18]. Four estimators were compared: (A) OLS on condition means, (B) OLS on 60 s blocks, Deming regression on 60 s blocks (DB) and Deming regression on condition means (DM). The Deming slope is given by Equation (7), where δ is the ratio of the error variance of the dependent variable U to that of the predictor V, and S denotes centered sums [19]:
a = [ S yy − δ · S xx + √ ( ( S yy − δ · S xx ) 2 + 4 δ · S xy 2 ) ] / ( 2 · S xy )
The two error variances were estimated from replicate measurements that are independent of the regression residuals. For block fits, the error variance of V was the within-condition block variance pooled over the calibration conditions and weighted by degrees of freedom (equal weights, n = 33 per condition); for condition-mean fits it was the mean of SD2/n. Because the true U is constant within a steady condition, the deviation of each block from its condition mean is the component of V that causes regression dilution, whether it arises from instrument noise or from real velocity fluctuations. The error variance of U was the mean of (Uref · CVQ/√10)2, i.e., the variance of the mean of ten moving-boat transects. In the three-condition block fit, δ was 0.006 for the SL-500 and 0.045 for the SL-1500. The sensitivity to δ was evaluated by scaling δ from ×0.5 to ×10 (Table A1). The upper value corresponds to assigning the variance of a single transect, rather than of the ten-transect mean, to the reference velocity, i.e., to fully correlated transect errors. Over this range, the three-condition slope changed by less than 1.5% (SL-500, 0.846–0.859; SL-1500, 0.969–0.983). The low-velocity extrapolation bias of block Deming regression was stable for ±50% changes (SL-500: +16.3% to +19.1%) but increased to +39.1% at ×10, approaching the block OLS result as δ increases. For small δ, block Deming regression approaches regressing V on U and inverting, and because all blocks of a condition share the same reference error, the assumption of independent errors is not strictly satisfied. Block Deming regression is therefore used as a diagnostic of regression dilution, and condition-mean fitting, which does not depend on δ in the two-condition leave-one-condition-out (LOCO) fits (estimators A and DM coincide), is recommended for rating estimation.
Transferability was assessed by LOCO validation, in which a rating fitted on two conditions predicts the third (C1 + C2 → C3, low-velocity extrapolation; C1 + C3 → C2, interpolation; and C2 + C3 → C1, high-velocity extrapolation). With two calibration conditions, there is only one line through the two condition means, so estimators A and DM coincide. For each LOCO prediction, a noise floor √(u(Uref)2+u(V)2) was computed from the standard uncertainties of the reference velocity and the condition-mean index velocity, and a bias was regarded as exceeding the measurement noise only when it exceeded twice this floor. The floor includes the random uncertainties of the reference velocity and of the condition-mean index velocity, but not the uncertainty of the rating coefficients fitted to two conditions or systematic errors common to all conditions (e.g., in stage or wetted area); it is therefore a lower bound of the prediction uncertainty rather than a formal significance test.

2.4. Experimental Channel and Cross-Section

The experiments were conducted in a fixed-bed concrete compound channel. The compound channel has a longitudinal slope of 1/800 and a compound-section reach length of 150 m. Measurements were conducted at a cross-section located 95 m from the upstream end of the compound reach, where the flow was considered sufficiently developed and stable. The cross-section is defined by nine surveyed points (Table 1) with a total width of about 11.07 m and consists of a steep left bank, a floodplain (X ≈ 1.1–6.6 m, bed elevation about 0.76–0.80 m), a main channel (X ≈ 6.6–9.3 m, about 0–0.12 m) and a steep right bank (Figure 1). The wetted area at a given water-surface elevation was computed by trapezoidal integration with explicit treatment of the waterline intersections.
Table 1. Surveyed cross-section points (X, distance from the left bank; Y, bed elevation above the lowest point).
Figure 1. Cross-section, positions of the H-ADCPs and SL-500 cells, and water-surface elevations (WSE) of the three conditions (solid, SL-1500 stage; dashed, SL-500 stage for Case 1). Black dotted lines indicate the horizontal profiling paths of the H-ADCPs.

2.5. Instrumentation

A SonTek SL-500 (SonTek, San Diego, CA, USA; five cells) was installed on the left bank at X = 1.0 m and an elevation of 1.268 m, profiling from left to right, and a SonTek SL-1500 (19 cells) was installed at X = 9.505 m and an elevation of 0.546 m in the main channel, profiling from right to left (Table 2; Figure 2). The SL-500 cells were located 4.5, 6.0, 7.5, 9.0 and 10.5 m from the left bank; Cell 5 is not valid because the bed of the right bank there (about 1.30 m) is higher than the beam elevation. Point velocities were measured with a Nortek Vector ADV (Nortek AS, Rud, Norway) at the SL-500 cell locations and elevation, and the reference discharge was measured with a SonTek RiverSurveyor M9 (SonTek, San Diego, CA, USA) on an upstream section with ten repeated transects per condition. OTT Orpheus Mini (OTT HydroMet GmbH, Kempten, Germany) pressure gauges 2 m upstream and downstream of the H-ADCPs independently monitored steadiness and stage changes. The manufacturer-specified accuracies (Table 2) describe instrument performance under reference conditions. Because the specified H-ADCP velocity accuracy includes a constant term of ±0.005 m/s, its relative value increases from about ±3.8% at 0.181 m/s to ±7.5% at 0.077 m/s; any part of this error that remains constant across conditions is absorbed by the rating (Equation (3)).
Table 2. Instruments and deployment.
Figure 2. Experimental channel and H-ADCP installations. (a) Compound channel viewed in the downstream direction without flow, showing the floodplain (left) and main channel (right) and the SL-500 (left bank) and SL-1500 (right bank) on their mounting rails; (b) SL-500 on the left-bank mounting rail; and (c) channel viewed in the upstream direction during the experiments, with the floodplain inundated and the measurement carriage.

2.6. Experimental Conditions and Data Processing

Three steady flows of different discharges were examined (Table 3). The channel is fed by six supply pipes (two each of 300, 400 and 500 mm diameter), and the flows were set by the combination of open pipes with all downstream gates fully raised: all six pipes in Case 1, one pipe of each diameter in Case 2, and a single 500 mm pipe in Case 3. Case 1 therefore corresponded to the maximum supply capacity of the facility. The lowest flow was selected so that the SL-500 beams remained submerged: in Case 3, the water surface was only 7.8 cm above the SL-500 transducer, and a further reduction in discharge would have left its beams insufficiently submerged. The floodplain was inundated in all cases (flow depth on the floodplain of about 0.55 m or more), so the three conditions represent the same overbank flow regime. The conditions were designed not to define a rating over a wide range of flows but to provide the minimum configuration for leave-one-condition-out validation, i.e., one interpolation test and one extrapolation test at each end of the calibration range (Section 2.3). In each condition, the ADV and moving-boat measurements were conducted first, and the H-ADCPs then recorded for at least 30 min. The central 200 samples of each 10 s H-ADCP record were analyzed. The reference cross-sectional mean velocity was defined as Uref = Q/A, with A computed from the surveyed section at the water-surface elevation measured by the SL-1500, following the stage verification in Section 3.1. Streamwise velocity components were used; for the SL-500, combinations of Cells 1–4 served as index-velocity candidates, and for the SL-1500, the instrument index velocity was used.
Table 3. Experimental conditions (water-surface elevation and wetted area based on the SL-1500 stage).

3. Results

3.1. Flow Steadiness and Consistency of Stage and Wetted Area

The stage was steady in all three conditions. Linear trends fitted to the stage records during the analyzed H-ADCP periods (about 33 min) were within ±0.042 mm/min for the upstream and downstream OTT gauges and the SL-1500 and within ±0.074 mm/min for the SL-500, corresponding to stage changes of, at most, 1.4 mm and 2.5 mm, respectively, and to changes in wetted area of less than 0.3%. Because the moving-boat measurements preceded the H-ADCP records (Section 2.6), the stage was also compared between the two periods: the OTT stage changed by at most 2.2 mm from the start of the moving-boat measurements to the end of the H-ADCP records (52–113 min), and the mean stages of the two periods differed by no more than 2 mm. In Case 2, however, both H-ADCPs independently showed a slight increase in velocity (about 1.3–4.3%, within the reference discharge uncertainty) at constant depth.
At the same section and time (alignment offset 0–5 s), the SL-500 water-surface elevation was 7.5–9.7 cm higher than that of the SL-1500, which produced a wetted-area difference of 9.0–10.6% relative to the area at the SL-500 stage (Table 4). The internal areas of both instruments agreed with the surveyed section evaluated at their own stage (0.0% and −0.4% to −0.5%), so the area difference originates from the stage rather than the section definition. The two SL-1500 depth measurements (acoustic vertical beam and barometrically compensated pressure) agreed within 1 mm, and the SL-1500 stage changes between conditions agreed with both OTT gauges (ratio 0.97–1.01). The SL-500 stage included an internal offset of about −0.081 m and exaggerated the changes between conditions by a factor of 1.22–1.36 (Figure 3). The SL-1500 stage was therefore adopted as the reference. It is the sum of the transducer elevation surveyed by real-time kinematic global positioning system (RTK-GPS) before the experiments (0.546 m) and the water depth measured acoustically by the vertical beam, so it does not depend on barometric compensation, and its relative changes were consistent with the pressure measurement and with two external gauges; the water surface itself, however, was not independently surveyed (Section 4.5). With this reference, Uref is 9.5–11.3% larger than with the SL-500 stage. The stage discrepancy does not affect the velocities measured by either instrument; it affects only the wetted area and, through Uref = Q/A, the reference mean velocity, by a similar proportion in all conditions. When the SL-500 stage was used instead, the rating slopes changed by about 12%, but the conclusions of this study were unchanged (Section 4.5).
Table 4. Stage and wetted area of the two H-ADCPs at identical times.
Figure 3. Independent check of stage changes between conditions (SL-500, SL-1500, and the upstream and downstream OTT gauges).

3.2. Precision Versus Averaging Duration

The lag-1 autocorrelation of the 10 s records was small (|r1| ≤ 0.17), and for most averaging durations, the standard deviation of the non-overlapping block means lay within the 95% confidence interval of the independent-sample prediction (Figure 4a). Within the record length (about 2000 s), the uncertainty therefore continued to decrease as 1/√m, and no saturation at a particular averaging duration was observed. Because the number of non-overlapping blocks decreases with averaging duration (33 blocks at 60 s and 6 at 300 s), this test loses power at long durations; at 300 s, for example, the 95% confidence interval of the CV in Case 1 spanned 1.4–5.5%. The 1/√m behavior is therefore supported within the analyzed record length and not beyond it. Analyses that overlap averaging windows to keep the sample size fixed can make the improvement appear to stall at long durations because of artificial correlation. The 10 s CV of the index velocity (Cells 2 + 3 + 4) increased from 26.1% to 33.7% and then to 64.0% as velocity decreased, whereas the absolute temporal standard deviation remained almost constant at 0.057, 0.063 and 0.062 m/s for 10 s samples and 0.024, 0.023 and 0.023 m/s for 60 s averages (standard deviation of the 33 non-overlapping 60 s block means). The 95% confidence intervals of the 10 s standard deviations overlapped across the three conditions (0.052–0.063, 0.057–0.070 and 0.056–0.069 m/s), and the independently operated SL-1500 likewise showed a nearly constant standard deviation (0.021, 0.020 and 0.019 m/s) while its CV increased as the mean velocity decreased (Section 3.6). The large relative error at low velocity is thus consistent with a denominator effect of the smaller mean velocity rather than an increase in the absolute variability. A constant total standard deviation could, in principle, result from opposite changes in instrument noise and in real velocity fluctuations, which cannot be separated with the present data (Section 2.2); the increase in CV is therefore attributed mainly, rather than exclusively, to the decrease in mean velocity. When the absolute variability is nearly constant, the averaging duration required for a given relative precision increases sharply as velocity decreases. The averaging duration required for a CV of 5% was about 270, 450 and 1640 s (Table 5). The Allan deviation of Case 1 decreased up to 660 s, whereas it leveled off between 180 and 300 s in Case 2 and at about 8–9% beyond 300 s in Case 3 (Figure 4b). This flattening suggests low-frequency variability; however, beyond 300 s fewer than seven non-overlapping averages are available in each record, so the Allan deviation is uncertain at these time scales, and the batch-mean standard deviations remained within the confidence interval of the 1/√m prediction for most averaging durations (Figure 4a).
Figure 4. (a) CV of a single average from non-overlapping batch means with 95% confidence intervals (dashed lines: 1/√m). (b) Overlapping Allan deviation.
Table 5. CV (%)/absolute standard deviation (m/s) of a single T-second average of the index velocity (Cells 2 + 3 + 4) and the required averaging duration.

3.3. Systematic Offset of the SL-500 Relative to the ADV

The SL-500 cell velocities showed positive offsets relative to the collocated ADV for all cells and conditions (Case 1, +4.8 to +5.3 cm/s; Case 2, +2.9 to +5.8 cm/s; and Case 3, +1.0 to +2.6 cm/s; Figure 5). These offsets were practically unchanged when the averaging duration was increased from 60 to 300 s and are therefore systematic rather than caused by insufficient averaging. Because the two instruments sample different volumes, the difference is interpreted as a systematic offset relative to the collocated ADV rather than as an instrument accuracy error. These offsets exceed the specified velocity accuracy of the SL-500 (±1% ±0.005 m/s; Table 2), which also suggests that they reflect differences in sampling volume and local flow rather than an instrument accuracy error. The fact that the sign of this offset is opposite to the low-velocity underestimation reported previously [1] suggests that the direction of low-velocity bias depends on installation geometry, acoustic path and local flow structure. Cell 5, where the beam intersects the bank, reached a relative uncertainty of up to 83% and was excluded.
Figure 5. Difference between SL-500 cell velocities and collocated ADV point velocities.

3.4. Index-Cell Selection: Precision Versus Transferability

The pooled R2 of the 60 s blocks was highest for Cells 2 + 3 + 4 (0.834), but the ranking changed when combinations were judged by LOCO prediction error (Table 6). Interpolation and high-velocity extrapolation errors were within about ±5% for most combinations, whereas the low-velocity extrapolation error (C1 + C2 → C3) ranged from −18% to +41% depending on the combination. Combinations including Cell 2, located at the floodplain–main-channel transition (X = 6.0 m, bed 0.41 m), consistently produced large positive errors (+10% to +41%), whereas Cell 1 or Cell 4 alone produced negative errors. Combinations with errors close to zero (e.g., Cells 1 + 3) result from cancellation of curvature of opposite sign and should not be generalized as optimal. Pooled R2 primarily reflects within-condition scatter (temporal precision), whereas LOCO error reflects the linearity of the condition-mean U–V relation (transferability); the two criteria therefore evaluate different properties.
Table 6. Pooled R2 and LOCO prediction bias of SL-500 cell combinations (condition-mean fit; SL-1500 stage reference).

3.5. Rating Estimators and Calibration Range

For the SL-500 index velocity (Cells 2 + 3 + 4), the block OLS slope (0.717) was about 17% smaller than the condition-mean slope (0.859) (Figure 6; Table 7). Applying Deming regression to the same blocks gave a slope of 0.858, close to the condition-mean slope, indicating that the reduction in the block OLS slope is mainly due to regression dilution caused by the scatter of the index velocity. In LOCO validation, block OLS produced a large error of +83.1% for low-velocity extrapolation. Condition-mean and Deming fits gave small errors for interpolation (−2.0%) and high-velocity extrapolation (+2.3%), but +14.9% to +17.7% remained for low-velocity extrapolation (Figure 7). Twice the noise floor was 8.9% for Case 3, and 4.6–4.9% for Cases 1 and 2, so only the low-velocity extrapolation bias exceeded twice the noise floor, whereas the interpolation and high-velocity extrapolation biases lay within it. Methods that reduce the influence of predictor error remove the dilution but cannot remedy extrapolation below the calibration range; in the tested conditions, the velocity range represented by the calibration data was more influential than the number of calibration conditions.
Figure 6. Relation between index velocity and reference mean velocity with the fitted lines of each estimator: (a) SL-500 index velocity (Cells 2 + 3 + 4); (b) SL-1500 index velocity. Small symbols, 60 s blocks; large symbols, condition means ± standard uncertainty.
Table 7. Three-condition slopes, LOCO prediction bias and predicted velocity for low-velocity extrapolation (reference value for Case 3: 0.077 m/s).
Figure 7. Prediction bias of the held-out condition in LOCO validation: (a) SL-500 index velocity (Cells 2 + 3 + 4); (b) SL-1500 index velocity. Bars exceeding the plotted range (−40% to 90%) are truncated, and exact values are annotated.

3.6. Main-Channel-Focused Measurement (SL-1500)

The CV of the SL-1500 60 s block index velocity (4.3%, 5.5% and 10.6%) was lower than that of the SL-500 (11.0%, 12.1% and 24.2%), indicating higher temporal precision. The LOCO errors, however, were larger than for the SL-500 (+7.4% for interpolation and −7.3% for high-velocity extrapolation) and exceeded twice the noise floor (2.9–3.1%). For low-velocity extrapolation, both methods accounting for predictor error (A and DB) predicted negative velocities of −0.012 to −0.008 m/s (bias −110% to −116%). These negative values are not physically meaningful; they demonstrate the failure of linear extrapolation beyond the calibrated hydraulic range. The failure arises because the C1 and C2 condition means lie close together and off the line through C3; block OLS appears better (+31%) only because its attenuated slope is pulled toward the mean. The main-channel-focused configuration was therefore more precise but, under the tested conditions, less transferable between conditions.

4. Discussion

4.1. Sources of the Larger Errors at Low Velocity

The larger errors observed at low velocity arise from three distinct mechanisms that should not be conflated. First, the relative precision of a single average deteriorated because the absolute temporal standard deviation of the index velocity remained nearly constant (0.057–0.063 m/s for 10 s samples) while the mean velocity decreased; the CV therefore increased approximately in inverse proportion to the mean velocity (Section 3.2). This component is random and can be reduced by longer averaging. Second, the rating error increased when the low-velocity condition was predicted from a rating calibrated at higher velocities (+14.9% to +17.7% for the SL-500, and −110% to −116% for the SL-1500), because the condition-mean U–V relation was not linear over the tested range (Section 3.5 and Section 3.6). This component is systematic and is reduced neither by longer averaging nor by errors-in-variables estimation, whereas block OLS amplified it through regression dilution (+83.1%). Third, the shallow submergence of the SL-500 beams (7.8–15.7 cm) and the location of Cell 2 at the floodplain–main-channel transition may have increased the scatter and cell-to-cell instability, although these mechanisms could not be isolated with three conditions (Section 4.3). By contrast, the wetted-area difference caused by the stage discrepancy between the two sensors (9.0–10.6%) did not increase at lower velocity.
The SL-500 offset relative to the ADV was stable irrespective of averaging duration and can be absorbed by the IVM slope and intercept. Low-velocity H-ADCP performance should therefore not be judged solely by instantaneous velocity accuracy; the stability and linearity of the relation across conditions and the temporal precision must be considered together.

4.2. A Rule for the Averaging Duration

Because the 10 s samples behaved approximately as independent observations within the analyzed records, it is reasonable to set the averaging duration from a target precision as Treq = 10 · (CV10/e)2. The rule shows quantitatively that the required duration grows sharply at low velocity (270 s versus 1640 s for a CV of 5%). If the observed lag-1 autocorrelations of the index velocity (−0.12 to +0.07) are accounted for with a first-order autoregressive model, Treq changes by a factor of (1 + r1)/(1 − r1), i.e., by −21% to +16%, which does not alter this conclusion. In Case 3, however, Treq approaches the record length, so this value is an application of the rule rather than a directly verified duration. With the 430 s averaging duration used by Korean discharge-measurement agencies (assuming each 10 s sample is an average over its interval), the CV is about 4–10%, which may not meet a target precision under low-velocity conditions. The flattening of the Allan deviation in Cases 2 and 3 suggests that longer averaging may yield limited gains where low-frequency variability is present. Possible sources include the slight increase in velocity during Case 2 (Section 3.1), which acts as a drift and raises the Allan deviation at long time scales, slow fluctuations of the inflow and large-scale unsteady structures at the floodplain–main-channel interface. The present records are too short to separate these sources, and the flattening is therefore reported as an indication of possible low-frequency variability rather than as an established noise floor. Where such variability is confirmed by longer records, it would set a practical upper limit on the averaging duration.

4.3. Spatial Representativeness of the Index Velocity and Installation

In the IVM, the index velocity is not required to equal the cross-sectional mean velocity, because a constant or proportional difference is absorbed into the rating (Equation (3)). Spatial representativeness in this sense requires that the relation between the index velocity and the mean velocity remain stable across conditions. Because Uref was obtained from the discharge measured upstream and the wetted area at the H-ADCP section, it represents the cross-sectional mean velocity irrespective of the velocity distribution at that section, and the stability of the relation was assessed indirectly by the LOCO validation (Section 3.4) rather than by measuring the velocity distribution. The two instruments sampled only parts of the section: the SL-500 beams sampled a horizontal layer only 7.8–15.7 cm below the free surface across the floodplain and main channel, and the SL-1500 sampled only the main channel. In a compound channel, the partition of discharge between the main channel and the floodplain and the momentum exchange at their interface change with stage, so the ratio of such a partial-section index velocity to the cross-sectional mean velocity can vary between conditions. The dependence of the LOCO errors on cell selection (Table 6) and the low transferability of the main-channel-focused SL-1500 (Section 3.6) are consistent with such variation. However, the velocity distribution over the section, the flow exchange between the main channel and floodplain, and the vertical velocity profiles at the index cells were not measured, so these mechanisms could not be verified directly.
The low transferability of combinations including the transition cell (Cell 2) is an observation. This behavior may reflect changes in the local velocity distribution near the floodplain–main-channel transition as stage varies, but three conditions cannot establish the cause, and it remains a hypothesis. Moreover, with the SL-1500 stage as the reference, the water depth above the SL-500 transducer was only 7.8–15.7 cm (15.2–25.4 cm with the SL-500 stage). With the beam so close to the free surface, surface-reflection interference [1] may contribute to the large scatter and cell-to-cell instability of the SL-500. Surface reflections, however, are generally reported to bias velocities low [1], so the positive offset of the SL-500 relative to the ADV cannot be explained by this mechanism alone and requires further investigation that includes other factors, such as the difference in sampling volumes.

4.4. Implications for Field IVM Calibration

Ratings should be estimated by condition-mean fitting (or an errors-in-variables approach); OLS on 60 s blocks dilutes the slope and severely degrades extrapolation. More importantly, the calibration data must cover the operating range, particularly the lowest velocities. IVM calibration campaigns should therefore be designed so that the lowest velocities to be monitored fall within the calibration range, and discharges below that range should be flagged as having substantially increased uncertainty. The ≈10% area difference caused by the stage discrepancy between the two sensors further shows that, since Q = U · A, stage (and hence area) consistency is a prerequisite for both the reference velocity and the rating. The stage used to compute the reference velocity and the stage used for the operational wetted area must share the same datum.

4.5. Limitations

This study (i) considered only three hydraulic conditions within a narrow velocity range (0.077–0.181 m/s); because each LOCO rating was fitted to two conditions, the linearity of the index–mean velocity relation could not be tested statistically, and the curvature inferred from the LOCO errors may be specific to the tested conditions. This study also (ii) covered a narrow range of water-surface elevations (1.35–1.43 m) and was conducted (iii) in a controlled fixed-bed channel (iv) with a single compound cross-section. In addition, (v) the water surface was not independently surveyed; the SL-1500 stage relies on the RTK-GPS-surveyed transducer elevation and its acoustic depth measurement, and its adoption is further supported by the agreement of its relative changes with independent gauges. Moreover, (vi) the slight flow increase in Case 2 and the difference in the recording periods of the two instruments may have affected the LOCO results; (vii) each LOCO value is a single prediction and must be interpreted together with its noise floor; and (viii) the spatial representativeness of the index velocities was evaluated only through the transferability of the ratings, without measurements of the velocity distribution across the section or of the exchange between the main channel and floodplain. When Uref was based on the SL-500 stage instead, the slopes changed by about 12%, but the conclusions regarding block OLS dilution, low-velocity extrapolation error and the low transferability of the SL-1500 were unchanged. The derived rating coefficients should therefore not be interpreted as transferable field ratings; the results provide evidence on the relative influence of averaging duration, cell selection, rating estimation and calibration range. The direction of these effects (e.g., the need for longer averaging at low velocity, the slope attenuation by block OLS and the bias outside the calibration range) follows from the statistical and hydraulic mechanisms described above, whereas their magnitudes (e.g., the required averaging durations and the extrapolation biases) apply to the tested conditions. Additional conditions, particularly at and below the lowest velocity tested here, are needed to establish the shape of the index–mean velocity relation at low velocity and to generalize these magnitudes.

5. Conclusions

Reliable discharge records at low flows are needed for water supply, drought management and environmental flow assessment, yet low velocities are where acoustic index-velocity stations are least reliable. In practical terms, this study indicates that, under the tested conditions, the accuracy of low-flow discharge depended less on the instantaneous accuracy of the velocity sensor than on decisions made by the operator: how long the velocity is averaged, which part of the cross-section is used as the index, how the rating is fitted and whether the calibration measurements include the lowest flows, together with the use of a consistent water-level reference. These factors can be checked with existing instruments and routine calibration campaigns, and the guidelines at the end of this section translate the findings into practice.
Two H-ADCPs were analyzed under three steady low-velocity conditions (0.077–0.181 m/s) in a compound experimental channel, leading to the following conclusions, whose quantitative values apply to the tested conditions.
First, the 10 s samples behaved approximately as independent observations over the analyzed record, and the precision of a single average followed a 1/√m law. The absolute temporal standard deviation of the index velocity was nearly constant across conditions, so the large relative error at low velocity resulted mainly from the smaller mean velocity. There is thus no fixed optimal averaging duration; the duration should be set from a target precision as Treq = 10 · (CV10/e)2, and it increased sharply at low velocity (≈270–1640 s for a CV of 5%, with the upper value approaching the analyzed record length).
Second, the systematic offset of the SL-500 relative to the ADV was stable irrespective of averaging duration and can be absorbed by the IVM. The boundary cell (Cell 5) cannot be used because its beam intersects the bank.
Third, OLS on 60 s blocks underestimated the slope by about 17% through regression dilution, and Deming regression on the same blocks gave a slope close to the condition-mean level. However, the error of extrapolation below the calibration range (+15–18%) persisted even with estimators accounting for predictor error, so IVM accuracy depends on the velocity range represented by the calibration data, particularly whether the lowest velocities are included.
Fourth, the cell combination with the highest pooled R2 was not the most transferable, and the floodplain–main-channel transition cell markedly increased the low-velocity extrapolation error. The main-channel-focused SL-1500 had higher temporal precision but, under the tested conditions, predicted physically meaningless negative velocities when extrapolated below the calibration range.
Fifth, the stages of the two sensors at the same section differed by 7.5–9.7 cm, producing a wetted-area difference of about 10%. The SL-1500 stage was adopted as the reference because it is referenced to its RTK-GPS-surveyed transducer elevation and its relative changes were consistent with independent gauges. The water depth above the SL-500 transducer was then only 7.8–15.7 cm, suggesting that surface-reflection interference may contribute to the large scatter of the SL-500 (the cause of its positive offset relative to the ADV remains unresolved). Stage (area) consistency is a prerequisite for computing the reference velocity and operating the IVM.
The following guidelines are proposed for low-velocity H-ADCP discharge estimation: (1) choose the deployment elevation and cells so that the beams traverse the water column with sufficient clearance, and scrutinize boundary and transition cells; (2) set the averaging duration from a target precision and examine long-period variability with the Allan deviation, using records sufficiently longer than the intended averaging duration; (3) estimate the rating by condition-mean fitting (do not apply OLS to 60 s block data) and design calibration campaigns so that the lowest operational velocities fall within the calibration range; and (4) use the same stage datum for the reference velocity and the operational discharge computation, and cross-check the stage with independent gauges.

Author Contributions

Conceptualization, J.K. and Y.G.; methodology, J.K. and Y.G.; formal analysis, J.K.; investigation, J.K. and Y.G.; data curation, J.K., Y.G. and M.K.; writing—original draft preparation, J.K. and S.-H.J.; writing—review and editing, J.K., Y.G., M.K. and S.-H.J. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by Korea Environment Industry & Technology Institute (KEITI) through Research and development on the technology for securing the water resources stability in response to future change Program, funded by Korea Ministry of Climate, Energy and Environment (MCEE) (RS-2024-00336020).

Data Availability Statement

The data presented in this study are available upon request from the corresponding author. The data are not publicly available because they were generated within an ongoing research project funded by the Korea Ministry of Climate, Energy and Environment (MCEE) through the Korea Environment Industry & Technology Institute (KEITI) (RS-2024-00336020).

Conflicts of Interest

The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

Appendix A

Table A1. Sensitivity of the three-condition slope and the low-velocity extrapolation bias (C1 + C2 → C3) of block Deming regression to the error-variance ratio, δ (SL-1500 stage reference). The ×10 case corresponds to assigning the single-transect variance, instead of the variance of the ten-transect mean, to the reference velocity.

References

  1. Le Coz, J.; Pierrefeu, G.; Paquier, A. Evaluation of river discharges monitored by a fixed side-looking Doppler profiler. Water Resour. Res. 2008, 44, W00D09. [Google Scholar] [CrossRef] [Scilit]
  2. Levesque, V.A.; Oberg, K.A. Computing Discharge Using the Index Velocity Method; U.S. Geological Survey Techniques and Methods 3-A23; U.S. Geological Survey: Reston, VA, USA, 2012. [Google Scholar]
  3. Nihei, Y.; Kimizu, A. A new monitoring system for river discharge with horizontal acoustic Doppler current profiler measurements and river flow simulation. Water Resour. Res. 2008, 44, W00D20. [Google Scholar] [CrossRef] [Scilit]
  4. Hidayat, H.; Vermeulen, B.; Sassi, M.G.; Torfs, P.J.J.F.; Hoitink, A.J.F. Discharge estimation in a backwater affected meandering river. Hydrol. Earth Syst. Sci. 2011, 15, 2717–2728. [Google Scholar] [CrossRef] [Scilit]
  5. Mueller, D.S.; Abad, J.D.; García, C.M.; Gartner, J.W.; García, M.H.; Oberg, K.A. Errors in acoustic Doppler profiler velocity measurements caused by flow disturbance. J. Hydraul. Eng. 2007, 133, 1411–1420. [Google Scholar] [CrossRef] [Scilit]
  6. Muste, M.; Kim, D.; González-Castro, J.A. Near-transducer errors in ADCP measurements: Experimental findings. J. Hydraul. Eng. 2010, 136, 275–289. [Google Scholar] [CrossRef] [Scilit]
  7. Sassi, M.G.; Hoitink, A.J.F.; Vermeulen, B.; Hidayat, H. Discharge estimation from H-ADCP measurements in a tidal river subject to sidewall effects and a mobile bed. Water Resour. Res. 2011, 47, W06504. [Google Scholar] [CrossRef] [Scilit]
  8. Kiang, J.E.; Gazoorian, C.; McMillan, H.; Coxon, G.; Le Coz, J.; Westerberg, I.K.; Belleville, A.; Sevrez, D.; Sikorska, A.E.; Petersen-Øverleir, A.; et al. A comparison of methods for streamflow uncertainty estimation. Water Resour. Res. 2018, 54, 7149–7176. [Google Scholar] [CrossRef] [Scilit]
  9. McMillan, H.; Krueger, T.; Freer, J. Benchmarking observational uncertainties for hydrology: Rainfall, river discharge and water quality. Hydrol. Process. 2012, 26, 4078–4111. [Google Scholar] [CrossRef] [Scilit]
  10. Rehmel, M. Field evaluation of shallow-water acoustic Doppler current profiler discharge measurements. In Proceedings of the World Environmental and Water Resources Congress 2006, Omaha, NE, USA, 21–25 May 2006; ASCE: Reston, VA, USA, 2007. [Google Scholar] [CrossRef] [Scilit]
  11. Oberg, K.A.; Mueller, D.S. Validation of streamflow measurements made with acoustic Doppler current profilers. J. Hydraul. Eng. 2007, 133, 1421–1432. [Google Scholar] [CrossRef] [Scilit]
  12. Muste, M.; Kim, J.; Kim, D. Impact of the sampling duration on the uncertainty of averaged velocity measurements with acoustic instruments. Hydrol. Process. 2021, 35, e14125. [Google Scholar] [CrossRef] [Scilit]
  13. JCGM 100:2008; Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement. Joint Committee for Guides in Metrology: Sèvres, France, 2008.
  14. Muste, M.; Kim, J.; Kim, D.; Despax, A. Implementation of standardized uncertainty analysis for streamflow measurements acquired with acoustic Doppler velocimeters. J. Hydraul. Eng. 2024, 150, 04024041. [Google Scholar] [CrossRef] [Scilit]
  15. Díaz Lozada, J.M.; Garcia, C.M.; Oberg, K.; Over, T.M.; Flores Nieto, F. Improvements to estimate ADCP uncertainty sources for discharge measurements. Flow Meas. Instrum. 2023, 90, 102311. [Google Scholar] [CrossRef] [Scilit]
  16. Kim, J.; Kim, D. Reducing the uncertainty assessment factors in discharge measurement by using the velocity-area method based on ISO standards. KSCE J. Civ. Eng. 2026, 30, 100520. [Google Scholar] [CrossRef] [Scilit]
  17. Allan, D.W. Statistics of atomic frequency standards. Proc. IEEE 1966, 54, 221–230. [Google Scholar] [CrossRef] [Scilit]
  18. Frost, C.; Thompson, S.G. Correcting for regression dilution bias: Comparison of methods for a single predictor variable. J. R. Stat. Soc. Ser. A 2000, 163, 173–189. [Google Scholar] [CrossRef] [Scilit]
  19. Cornbleet, P.J.; Gochman, N. Incorrect least-squares regression coefficients in method-comparison analysis. Clin. Chem. 1979, 25, 432–438. [Google Scholar] [CrossRef] [Scilit]
  20. SonTek. SonTek-SL Series Brochure; Xylem Inc.: San Diego, CA, USA, 2014; Available online: https://www.ysi.com/File%20Library/Documents/Brochures%20and%20Catalogs/sontek-sl-brochure.pdf (accessed on 19 November 2026).
  21. Nortek. Vector Technical Specifications; Nortek AS: Rud, Norway; Available online: https://www.nortekgroup.com/products/vector-300-m (accessed on 19 November 2026).
  22. SonTek. SonTek-M9 Specifications; Xylem Inc.: San Diego, CA, USA; Available online: https://www.ysi.com/sontek-m9 (accessed on 19 November 2026).
  23. OTT HydroMet. OTT Orpheus Mini Water Level Logger—Technical Data; OTT HydroMet GmbH: Kempten, Germany, 2011; Available online: https://s.campbellsci.com/documents/ca/product-brochures/orpheusmini_br.pdf (accessed on 19 November 2026).
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.