Abstract

Optical biosensors are analytical platforms with widespread applications in biotechnology, environmental monitoring, food safety, and clinical diagnostics. Among these, label-free optical biosensing has attracted considerable research interest, driven by advances in nanotechnology and photonic integration, which have enabled the development of compact device architectures, enhanced analytical sensitivity, and robust multiplexed detection capabilities. By eliminating the need for labels, these techniques simplify sample preparation, minimize label-induced interference, and facilitate real-time monitoring of binding kinetics. Despite these advantages, label-free optical biosensing platforms differ substantially in terms of their geometries, fabrication requirements, fluidic integration, and surface functionalization strategies. These differences make it challenging to assess their suitability based solely on detection limits. A comprehensive evaluation must therefore consider not only analytical performance but also the engineering requirements and practical considerations that govern their implementation. This review examines seven complementary label-free optical biosensing platforms developed for multiplexed detection, with particular emphasis on their operating principles, analytical capabilities, and progress toward integrated point-of-care applications. Through a comparative analysis of their analytical performance and implementation requirements, this review highlights the key technical trade-offs that determine the suitability of each platform for different analytical applications.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.