Abstract
Recently, numerous nations have found themselves in urgent need of an effective water desalination method that utilizes less energy and addresses water scarcity. A low-pressure desalination system is an appropriate technology for many regions due to its benefits, including minimal energy usage to achieve the evaporation threshold, substantial water output, and high-quality pure water. This work primarily aims to ensure the sustainability of low-pressure solar-powered desalination technology combined with a finned natural air-cooling condenser by providing a comprehensive analysis of the exergy, economic, and environmental aspects. Furthermore, innovative technology is a pioneer in generating freshwater continuously without affecting system pressure. Ambient temperature serves as a crucial sign of climate conditions, influencing the level of freshwater productivity, particularly when utilizing a natural air-cooled condenser. Consequently, this temperature has been thoroughly investigated through experiments and exergy analysis. Under the optimal conditions for this study, hsw = 15 cm, Tsw = 80 °C, and Tamb = 28 °C, the maximum productivity and GOR were obtained as 1020 g/hr and 1.2, respectively. Exergetic efficiency can reach a maximum of 3.48%. The economic analysis of the proposed system indicates that the cost of freshwater productivity is USD 0.042 per kilogram. Furthermore, the device’s first cost recovery period is roughly 183 days or 3.6% of its lifetime. The quantity and price of diluted CO2 over the lifetime of the device are 13 tons of CO2/year and 188.5 USD/year, respectively.
1. Introduction
Energy and water are the two primary resources essential for the progress and development of any country in fields such as agriculture, industry, and other activities. Recently, there has been a significant shortage of potable water due to the increasing global population, changing climate conditions, and global warming. On the other hand, the significant expansion of various industrial activities to meet the needs of the vast number of people for food and other life purposes has resulted in the consumption of large amounts of fossil fuel.
The Earth is called the blue planet because water represents about 70% of the Earth’s surface. The amount of potable water on Earth’s surface is about 3%, while the rest is saltwater. Freshwater is classified into two parts: approximately 0.5% is the net water that is directly usable in rivers and lakes, and 2.5% is found in glaciers, polar ice caps, and the atmosphere [1]. From 2000 to 2025, the amount of drinking water available per capita decreased by 27.27% globally [2]. Therefore, there is a great need for alternative sources to obtain potable water to compensate for decreased traditional sources that are reliable, cost-effective, and powered by renewable energy sources. Therefore, scientists have considered the seawater desalination process. Desalination is the process of removing excess salt from water to make it suitable for drinking or agriculture.
A large quantity of energy is consumed by desalination technologies to heat the fluids and run the devices and equipment [3]. Due to limited traditional energy resources and environmental impacts, the world requires environmentally friendly and efficient water desalination technologies powered by renewable energy. Therefore, integrating locally available renewable energy sources with desalination methods is considered an ideal solution to the problem of water scarcity. Solar energy accounts for almost 57% of the renewable energy employed in running desalination technologies [4]. Membrane (single-phase processes) and solar thermal (phase-change processes) desalination methods have been proposed [5]. These types of desalination are highly effective in zones rich in brackish water and solar energy, such as North Africa and West Asia [6]. Many different desalination technologies are powered by solar energy, such as solar still [7], multi-effect desalination [8], multi-stage flash [9], vapor compression [10], humidification and dehumidification [11], and membrane distillation [12]. An important advantage of these technologies is that they have less impact on the environment compared to technologies that run on traditional energy [13].
The low-pressure desalination technique represents one of the solar thermal desalination methods. It is a promising technology that has attracted considerable research attention in recent periods [14]. The low-pressure desalination technique offers several benefits, such as simple device components, high thermal efficiency, operation powered by low-energy sources like renewable energy or waste heat, and minimal heat loss to the environment [15,16].
A vacuum desalination technique driven by hybrid energy was examined by Bilgil and Hırlakoğlu [17]. Saltwater is heated using a solar collector and an electric heater without sunlight. The cost productivity of 0.630 L/h for the proposed system is approximately 0.020 USD/h, 0.031 USD/h, and 0.046 USD/h at condensation temperatures of 0 °C, −15 °C, and −25 °C, respectively. Sriram et al. [18] investigated the effects of having and not having a vacuum SS (solar still) system coupled with an external water-cooled condenser. The best performance can be obtained both with and without a vacuum SS system at a seawater depth of 2 cm in a basin. The results showed that the highest total freshwater productivity without and with the vacuum SS system was 2.3 L/day and 3.47 L/day, respectively.
Patel et al. [19] evaluated the double-slope vacuum SS system combined with an external condenser and external reflectors. The most important feature of the designed system is its ability to condense the steam almost completely. The experiments were carried out between 7:00 a.m. and 7:00 p.m. during the summer and winter seasons. The efficiency and daily productivity of the proposed summer and winter seasons were 76.66% and 54.74% and 11.5 L/day and 8.2 L/day, respectively. The sub-atmospheric pressure of a solar desalination system with an external air-cooled condenser was studied by Ibrahim et al. [20]. According to their findings, the highest efficiency achieved was 40%. Compared with atmospheric pressure solar desalination, the thermal efficiency and productivity of sub-atmospheric pressure increased by 29.7% and 16.2%, respectively. A vacuum distillation system combined with a flat-plate solar collector was created and tested experimentally by Morad et al. [21]. When increasing the seawater flow rate, water productivity increased, and costs were decreased by using a vacuum distillation system. The maximum daily productivity and cost productivity of the conventional and vacuum distillation systems were 7.27 L/day and 10.94 L/day and USD 0.030 and USD 0.031, respectively.
Ibrahim and Dincer [22] presented an assessment of a vacuum SS system integrated with a natural air condenser. The suggested system was simulated using a mathematical model created with MATLAB code. Many parameters were studied by the models, including energy stream rates, exergy stream rates, exergy destruction, and improvement potentials. The desalination system improves by 27%, 25%, and 39% for productivity, energy efficiency, and exergy efficiency, respectively, when the base basin absorptivity is increased from 0.85 to 0.95. Their outcomes show that the average daily production is about 0.7 L. Gude et al. [16] analyzed the exergy of low-temperature desalination. Three different heat source types, namely, photovoltaic energy, a low-grade heat source, and direct solar, were tested. The condenser is the largest element in the system’s exergy destruction due to the latent heat loss of water vapor to the surroundings. The exergy efficiencies of the desalination unit based on direct solar energy, photovoltaic energy, and an external reflector were 0.04%, 0.039%, and 0.051%, respectively. When utilizing a low-grade heat source, the exergy efficiencies of the condenser, evaporation chamber, and the heat exchanger were 1.31%, 19.88%, and 59.39%, respectively. Hosseini et al. [23] assessed the performance of a solar vacuum distillation device using a parabolic trough concentrator with vacuum heat exchange. According to the findings of the exergy and energy analysis, the highest energy and exergy efficiencies are 60.98% and 56.80%, respectively.
Ahmed et al. [1] published a literature review of recent research on vacuum SS systems powered by renewable energy. Vacuum SS technology was categorized into two major subsystems: forced and natural vacuum SS units. The results stated that the vacuum SS units increase productivity by 150% and improve system efficiency by 100%, compared to atmospheric pressure. The results of the study by Mohamed et al. [24] indicate that the forced and natural vacuum SS systems’ performance was improved by roughly 52% and 48%, respectively. In another survey for the evaluation of vacuum SS systems by Al-Obaidi et al. [25], their study focused on improving SS systems under vacuum conditions. The findings show that the vacuum SS system was improved by 30–305%, compared to the traditional system.
The increasing demand for freshwater in Egypt is due to rapid population growth. In addition, the amount of water coming from the Nile River is lower because of the construction of the Renaissance Dam in Ethiopia. On the other hand, Egypt enjoys good solar radiation all year round. According to published reports, Egypt has nine to eleven hours of sunshine per day, while cloudy days are very few. Meanwhile, the annual direct solar radiation intensity in the north and south varies between 1900 kWh/m2 and 2800 kWh/m2, respectively [26]. Moreover, Egypt has many saltwater sources, such as the Red and Mediterranean Seas [27]. There is no doubt that these sources of saltwater encourage the desalination process in Egypt using renewable energy. Therefore, the low-pressure desalination method is considered an effective and practical method in the climate conditions of Egypt, due to the availability of the basic sources, which represent saltwater sources and solar energy.
The advantages of using a natural air-cooled condenser include the following: simple design and installation, no moving parts or noise, no additional system components required, and less maintenance. However, its sole heat dissipation rates are lower than those of the surrounding environment. Fins are considered one of the most important methods used to enhance the performance of natural convection condensers and increase the rate of heat transfer [28]. Based on these features, a finned natural air-cooling condenser was used in this study.
Previous research connected to the current study was reviewed to determine the research gap, as shown in the above section. To the best of the authors’ knowledge, innovative technology can be used for continuous freshwater extraction without affecting the low-pressure system. In addition, a comprehensive analysis of the exergy and environmental and economic aspects of a low-pressure solar-powered desalination system integrated with a finned natural air-cooled condenser has not yet been conducted. Exergy analysis involves calculating the loss and efficiency ratio for each component individually. In addition, this identifies and calculates the potential for improving the system’s components. Therefore, the goal of the exergy analysis of the proposed unit is to determine the strengths and weaknesses of the design of the system components. The findings of the present work are divided into experiment results and an exergy analysis. Many operational parameters are studied, such as temperature, height of seawater, and ambient temperature. Moreover, numerous parameters of exergy analysis were evaluated, including the exergy destroyed in the condenser and evaporation chamber, as well as IR, IP, and FDR for both the evaporation chamber and condenser and the exergetic efficiency. Economic analysis focuses on determining the cost of one liter of water productivity. Finally, environmental and enviroeconomic analysis was carried out to identify the maximum quantity and cost of CO2 that could be removed from the environment.
2. Experimental Setup
2.1. System Description
A low-pressure desalination device consists of several parts, including an evaporation chamber, a finned natural air condenser (a vertical tube and horizontal fins), a condensation water-receiving cylinder, a condensation water-extracting cylinder, and a source of water heating. Furthermore, there are numerous other components and auxiliary devices, including a feed seawater tank, a container of condensation water, valves, a vacuum pump, and pipes, as presented in Figure 1.
Figure 1.
Schematic for a low-pressure desalination device.
The feed seawater tank is a cylindrical shape made of cast iron with a diameter, height, and thickness of 23 cm, 24 cm, and 0.2 cm, respectively. The seawater supply enters from the upper part, while the lower part contains a 1.25 cm diameter opening for entering the seawater into the evaporation chamber. The dimensions of the evaporation chamber are 23 cm in diameter and 30 cm in height. It is fabricated from cast iron with a thickness of 0.2 cm. A layer of glass wool (k = 0.036 W/m K) with a thickness of 2 cm is used to insulate and reduce heat loss from the evaporation chamber to the surrounding atmosphere. The house (heater hose) connection from the seawater storage tank to the evaporation chamber is made of stainless steel with a 1.25 cm diameter. The finned natural air-cooling condenser is a heat exchanger with vertical copper tubes and horizontal aluminum fins (length: 65 cm, number of tubes: 20, diameter of one tube: 0.93 cm, the length of horizontal square fins: 2 cm, separation between two consecutive fins: 0.14 cm, and number of fins: 410). The evaporation chamber and condenser are connected by a pipe that is 20 cm long and 2.5 cm in diameter.
The condensation water-receiving cylinder is made of cast iron, measuring 23 cm in diameter, 30 cm in height, and 0.2 cm thick. The condensation water extraction cylinder is made of cast iron and has a diameter, height, and thickness of 15 cm, 10 cm, and 0.2 cm, respectively. The connections used between the condenser, the condensation water-receiving cylinder, and the condensation water extraction cylinder are made of copper, 0.93 cm in diameter. The heating source used is an evacuated solar tube collector.
At the bottom and top parts of both the evaporation chamber and condensation water-receiving cylinder, the condensation water extraction cylinder has a conical shape to withstand pressure. The low-pressure desalination device is installed on a metal stand. Heavy-duty control valves are used to control the closing and opening between different system components.
2.2. The System Operation Method
Before conducting the system test, all components are rigidly connected. A vacuum test is then performed to check the system’s tightness. It is carried out by closing each of the following valves: V1, V3, V5, and V6. At the same time, the following valves are opened: V2 and V4. Figure 2 shows a photo of the suggested system. The vacuum process is carried out for all components, namely, the evaporation chamber, the condenser, the condensation water-receiving cylinder, and the condensation water-extracting cylinder. The starting pressure of the experiment is 4 kPa, depending on the surrounding temperature near the condenser. V2 and V4 are closed. V1 connects to the evaporation chamber, and the seawater storage tank is opened to receive the seawater to achieve the required seawater height for the evaporation chamber. The brine water extraction rate from the evaporation chamber is 350 g per hour. The seawater is heated. The seawater temperature gradually rises, and the seawater evaporates to reach the required temperature. The steam moves from the evaporation chamber to the condenser due to the temperature difference between them. The heat exchange process occurs between the hot steam entering the condenser and the cold surrounding atmosphere. Consequently, the steam condenses and turns into freshwater. The lower part of the condenser is a horizontal pipe with a slight inclination angle used to collect the freshwater in all the vertical condenser pipes and then transfer it down to the condensation water-receiving cylinder. The condensation water-receiving cylinder receives the condensed water for one hour. V2 is opened to transfer condensed water from the condensation water-receiving cylinder to the condensation water extraction cylinder. The condensate outlet hole is installed at the bottom of the conical part of the condensation water extraction cylinder, which helps to extract all the water condensation. We wait two minutes for all the condensed water to drain completely. V2 is closed to continue the evaporation process without stopping the system. Extracting the condensed water from the system, both V3 and V5 are opened to expose the condensation water extracted from the cylinder to atmospheric pressure. The condensed water is transferred from the condensation water extraction cylinder to the freshwater container. The condensed water is weighed on an electronic balance.
Figure 2.
Photo of the suggested system. (The red arrows represent the hot water exiting the evacuated tube solar collector and entering the evaporation chamber. The yellow arrows represent low-temperature hot water exiting the evaporation chamber and entering the evacuated tube solar collector.).
V3 and V5 are closed to empty the condensation water-extracting cylinder to obtain the condensed water in the following experiment. After that, the condensation water-extracting cylinder is discharged for two minutes using the vacuum pump. After another hour of experimenting, the same emptying method is repeated to achieve productivity. An innovative method is characterized by the fact that potable water is obtained during the operation of the experiment without the system being exposed to atmospheric pressure.
The valve states (V2, V3, and V5) can be summarized to ensure that the water-receiving cylinder remains evacuated during the freshwater extraction exposure to atmospheric pressure, as shown in Figure 3. In the first state, the three valves (V2, V3, and V5) are closed during the experimental operation. In the second state, we discharge freshwater from the water-receiving cylinder into the water extraction cylinder (V2 is open; V3 and V5 are closed). In the third state, freshwater is discharged from the water extraction cylinder to the atmosphere. V2 is closed, while V3 and V5 are open.
Figure 3.
Schematic of valve states (V2, V3, and V5) to make the water-receiving cylinder isolated from the discharge space during atmospheric discharge: (a) during the operation experiment, (b) freshwater discharged into the water-extracted cylinder, and (c) freshwater discharge into the atmosphere.
2.3. Measured Data
Several parameters are measured during the experiments to verify the performance of the low-pressure desalination unit. Practical measurements include temperature measurements, pressure measurements, solar radiation, and weight measurements of desalinated water. All temperature measurements use a T-type thermocouple (accuracy: ± 0.5 °C and range: 0–200 °C). Temperatures recorded at various locations in the device include the ambient temperature, the temperature of the seawater at the bottom of the evaporation chamber, the steam temperature at the top of the evaporation chamber, the condenser steam temperature, and the freshwater temperature. Operating pressure is measured using a pressure transmitter (range: 0–100 kPa and accuracy: ±0.1%). The freshwater is collected throughout the experiment period and then weighed at the end of the experiment using an electronic balance (range: 0.1–4500 g and accuracy: 0.01 g). Vacuum pump power is 0.240 kW. A pyranometer (range: 15–4000 W/m2 and accuracy: ±3%) is employed to gauge the solar intensity. All thermocouple temperature and pressure gauges are connected to the data logger. The experimental data is displayed and recorded on the computer device connected to the data logger. The pressure and temperature data are saved every minute, while freshwater production was manually recorded every hour.
2.4. Experimental Uncertainty Analysis
In metrology, error is known as the difference between the measured value and the measurement’s true value. Errors can be classified into two main categories: systematic error and random error. Random and systematic errors are essential factors that affect measurement accuracy. When experiments are conducted under fixed (unchangeable) conditions, random errors change, while systematic errors are unchangeable [29]. Moreover, random error is different based on the skills and possibilities available for experimentation. Systematic error relies on the accuracy of the measurement tools themselves. Therefore, the device’s accuracy is considered essential for evaluating the results of experimental work [30].
Uncertainty is defined as an interval approximately around the measured value. After determining a specific interval, we relate the possibility that the actual value of the measure falls within this range. Uncertainty is divided into two categories: Type A and Type B. First, Type A is uncertainty that can be measured using repeated results analysis and statistical methods. Second, Type B uncertainty can be calculated by researching specific information about a measurement in a data book, calibration report, instrument data sheet, or instrument supplier [29,31]. In the current study, data were recorded in the experimental work using digital devices with known accuracy. Thus, the uncertainty stemming from this result is classified as Type B. Therefore, uncertainty analysis was conducted for the experimental findings and the instruments used in the experiments. The standard uncertainty of the measurement devices was written and calculated from Equation (1) [32,33].
where u is the standard uncertainty of the measurement devices, and a refers to the instrument’s accuracy. The specifications of the measuring devices are represented by the standard uncertainty, range, and accuracy used in the experiments, as shown in Table 1.
Table 1.
Specification of the measuring devices used in experiments.
The following formula is used to determine the uncertainty analysis of Type B for many of the measured experimental data [11]:
where refers to uncertainty in the experiment measurements for Type B, and , , and represent the uncertainty of the measured value (x), the uncertainty of the measured value (y), and the value of the measured parameter, respectively. The maximum uncertainty values of GOR, SEC, and productivity are less than ±3.57%, ±2.1%, and ±0.31%, respectively.
Type A uncertainty was evaluated based on repeated experimental measurements, as reported in Refs. [34,35]:
where U is uncertainty for Type A, SD represents standard deviation, and N denotes the number of repeated measurements. Several parameters were determined to have uncertainties of Type A from measurements recorded during the repeated runs, including the evaporation chamber steam temperature, condenser steam temperature, desalinated water temperature, and operating pressure, which are ±0.23 °C, ±0.28 °C, ±0.45 °C, and ±0.24 kPa, respectively. In addition, system performance indicators were evaluated, including productivity, GOR, and SEC, with corresponding Type A uncertainties of ±8.7 g/h, ±0.018, and ±0.013 kWh/kg, respectively.
3. Exergy Analysis
The first law of thermodynamics (energy analysis) addresses often-used concepts in energy conversion/use processes. Conversely, the second law of thermodynamics focuses on the quality or type of energy used [36]. One application of the second law of thermodynamics is energy analysis. Recently, the term exergy analysis has been commonly used to understand the thermal processes of systems better. It is computed depending on the system’s experimental results [37]. Compared with energy analysis, exergy analysis provides better insights into many indicators, such as determining the optimal parameters for the system; identifying ineffective sources; determining the reasons, locations, and value of the process inefficiencies; and measuring the efficiency of using resources. Moreover, exergy analysis is performed to improve the system in the phases of development, design, and economic analysis [38].
Heat is transferred between two media from the source or the hot part (medium 1) to the sink or the cold part (medium 2), while energy transfer occurs based on the thermal gradient. In irreversible processes, heat transfer happens with a limited difference between the two media. Therefore, energy is degraded during the heat transfer process due to loss of heat and low temperature, which is called entropy generation. The generation of entropy and the decrease in the quantity of energy transmitted from the source to the sink reduce the energy availability on the sink side. This type of degradation is called exergy destruction (exergy loss) or irreversibility [16]. The relationship between the transfer of heat, entropy, and exergy is illustrated in Figure 4 [39].
Figure 4.
Simplified drawing for the relationship between heat, entropy, and exergy transfer [39].
The exergy property is termed the maximum useful work that a system can produce. Its definition is also the highest quantity of work that could be obtained from an amount of energy [39]. Equation (4) illustrates exergy analysis as follows: the exergy rate, , resulting from the amount of thermal energy, Q, at a temperature, T. The Carnot efficiency ( can be estimated from a thermal process operating between T and the reference temperature of the ambient [16].
Exergy can be transferred like energy from or to the system in three forms: heat, work, or mass flow. In reversible processes, the amount of thermal exergy is preserved (meaning the same value can restore it). Usually, all processes are real (irreversible processes), so the exergy output value is lower than the exergy input value. The exergy output value of the system includes part of the used outputs and other unused outputs. The unused exergy outputs flow into the environment, which is called irreversibility or exergy destruction (exergy loss). Exergy destruction is known as the potential work lost as a result of irreversibility. Under steady-state conditions, the exergy destruction of a control volume can be written as [22]
where refers to the exergy destruction within the component, (i). , , and are the sum of the exergy rate input, the sum of the exergy rate output, and the rate of exergy that the work transfers to or from the system, respectively. is exergy resulting from heat that is not radiation. It may be stated as [22]
The exergy resulting from the work rate can be written as [40]
The inflow and outflow of energy content are related to the streams that enter and exit the control volume. This can be evaluated in terms of physical flow exergy (), as per Ref. [41]. The effect of both kinetic and potential energy can be neglected in a control volume.
where and are the entropy and enthalpy of the boundaries where heat transfer takes place, respectively, while and represent values of the entropy and enthalpy of the fluid at the surrounding conditions, respectively.
To apply the exergy method in the suggested system, this study focuses on the main components: the condenser and the evaporation chamber. Exergy destruction rates are estimated for each process component separately in a steady state with the following expressions:
Exergy balance for evaporation chamber (EC):
Exergy balance for condenser (C):
where and are exergy destroyed in the evaporation chamber and exergy destroyed in the condenser, respectively, and is the amount of heat entering the system. Subscription ; ; ; sw;; and fw are feed seawater, brine, evaporation chamber vapor, seawater, condenser vapor, and freshwater, respectively.
The surrounding reference conditions for calculated exergy are called the dead state, with condition “0” representing a temperature of 25 °C (298 K) and a salt concentration of 3.5% [16]. Properties of the dead state are calculated for the same type of measured stream (freshwater, steam, or seawater).
Exergetic Performance Analysis
Many exergy analysis parameters are used to evaluate the effectiveness of low-pressure desalination systems. This is represented by the following elements: the irreversibility ratio (IR), the fuel depletion ratio (FDR), the rate of improvement potential (IP), the exergy loss and exergy efficiency of each part, and the overall exergetic efficiency of the system.
The IR of each component is known as the ratio of exergy destruction in each element to the overall system exergy destruction [38].
where represents the sum of the exergy loss in all system components.
The ratio of exergy destruction in each component of the desalination system to the ratio of the total exergy input to the system is defined as FDR. The FDR is written as follows [38]:
IP is employed to evaluate the performance of all elements of the desalination unit separately. It is an indicator of the possibility of improving the unit components to reach the ideal conditions. The IP is written as follows [36,38]:
The percentage of exergy loss and exergy efficiency for component (i) in the system is used individually as an indication to assess the system thermodynamic performance [16].
Exergetic efficiency is considered an important performance indicator for second law analysis in a desalination system. It is a gauge for the reversibility process of a system (the determined value of the benefit from the system). Exergetic efficiency is described as the exergy of freshwater condensed in the condenser (freshwater productivity) on the system exergy input. It can be written as [42,43]
The Engineering Equation Solver (EES) software (version number: Pro V10.561) is employed to solve the governing equations for exergy analysis. It contains a large database of properties for various fluids. The properties of seawater were obtained from research data by Sharqawy et al. [44].
4. Results and Discussion
Many practical experiments were performed for the low-pressure desalination system under temperatures from 50 °C to 80 °C, seawater heights in the evaporation chamber from 15 to 21 cm, and different ambient temperatures. The experimental test was conducted three times. The effect of various parameters studied is evaluated on freshwater productivity, GOR, and SEC. In addition, the system was assessed using exergy analysis. Exergy destroyed, the efficiency of all components of the desalination system, IR, IP, FDR, and the exergetic efficiency were studied. The results of the study are divided into sub-sections: experimental results and an analysis of the exergy findings.
4.1. Experimental Findings
4.1.1. Impact of Hourly Change on Performance Indicators
To evaluate the system performance, many temperatures were measured at various locations: ambient temperature (Tamb), evaporation chamber steam temperature (Tva, EC), condenser steam temperature (Tva, C), and freshwater temperature (Tfw). Experiments were conducted at different seawater temperatures between 50 °C and 80 °C, as illustrated in Figure 5a–d. As is clear in the figures, temperatures measured were considered almost stable over the duration of the experiment. The steam in the evaporation chamber and the hot seawater varied in temperature from 0.5 °C to 1.32 °C. The steam temperature entering the condenser was lower by 1.55–4.56 °C than the temperature of the hot seawater at Tsw between 50 °C and 80 °C, while the temperatures change between the hot seawater and freshwater was within the range of 7.3 °C to 15.75 °C. The significant difference between the seawater temperature in the evaporation chamber and the ambient temperature results in the condensation process. The ambient temperature is almost stable at 30 °C.
Figure 5.
Effect of operating time on temperatures measured at various locations of the system at Tamb = 30 °C and hsw = 15 cm.
Figure 6a–d demonstrate the variation in pressure with operational time at seawater heights of 15 cm, 17 cm, 19 cm, and 21 cm. When the experiment is started, the operating pressure is equal to the saturation pressure for the ambient seawater temperature. After that, the operation pressure begins to rise in accordance with the working conditions (the seawater height and hot seawater temperature in the evaporation chamber). The figures illustrate that the trend for the operation pressure is similar at all temperatures. At the same seawater temperature, the pressure slightly rises as the seawater height in the evaporation chamber rises. Compared with hsw = 15 cm and Tsw = 80 °C, when the seawater height increases to 17 cm, 19 cm, and 21 cm, the increase in pressure is 0.1 kPa, 0.66 kPa, and 0.94 kPa, respectively. This increase is due to the rise in the seawater level, as well as the reduced space above the seawater surface in the evaporation chamber.
Figure 6.
Impact of experiment time on the measured pressure in the system with different seawater temperatures at Tamb = 30 °C.
Figure 7 illustrates the effect of operating pressure before, during, and after water is extracted from the water-receiving cylinder into the water extraction cylinder. Before the water extraction process, the pressure fluctuation over time during the experimental operation is minimal, meaning that the pressure is considered almost stable. During the water extraction process, a pressure drop occurs due to the increased volume of the apparatus (the volume of the water extraction cylinder). The water is transferred under the influence of weight and gravity to the water extraction cylinder. After the water extraction process, the experimental pressure is considered almost as stable as it was before the extraction process. Therefore, the figure demonstrates that there is no ingress of air into the system during the extraction process.
Figure 7.
Variation in pressure with operating time before, during, and after water extraction from the condensation water-receiving cylinder at hsw = 15 cm, Tsw = 70 °C, and Tamb = 30 °C.
Figure 8a–d demonstrate the variation in the experimental time with respect to productivity (distillate mass rate (g/h)) at different temperatures and seawater heights. According to the steam table, as seawater temperatures increased to 50 °C, 60 °C, 70 °C, and 80 °C, the evaluated saturation pressure values became 12.1 kPa, 19.54 kPa, 30.56 kPa, and 46.45 kPa, respectively [1]. The operation pressure at the experiment startup is 4 kPa. The greater the difference between the saturation pressure and the starting pressure, the greater the amount of steam produced. Consequently, the system’s productivity is greater. Moreover, increasing seawater temperatures increases the movement of more water molecules. Consequently, the decrease in the surface tension of the water surface (this means the cohesive force of water molecules decreases) makes it easier to convert liquid water to a vapor state. When hsw = 15 cm, the system’s productivity is 295 g/h, 495 g/h, 710 g/h, and 956 g/h at Tsw of 50 °C, 60 °C, 70 °C, and 80 °C, respectively. Moreover, the system operates under vacuum pressure. Consequently, seawater reaches the vaporization point more quickly, causing the amount of water evaporated to increase. The feed seawater that enters the system has a salinity of 35,000 parts per million (ppm). The distilled salinity is almost 420 ppm. It is considered safe for drinking because it falls within the limits established by the World Health Organization [45]. The salinity of the desalinated water changed very little when the seawater temperature changed. It is consistent with the value mentioned in the Ref. [14]. This results from the design’s separation of the condenser and evaporation chamber.
Figure 8.
Variation in experiment time on productivity at different seawater heights and seawater temperatures.
Low-pressure desalination systems are known to be hermetically sealed, which makes it challenging to extract desalinated water during operations. This is only possible after the system as a whole has been exposed to atmospheric pressure [17]. Therefore, an innovative method was employed to obtain freshwater continuously without stopping the unit. The water-extracting cylinder is emptied to receive the water produced over an hour from the water-receiving cylinder and then closed off from the device. It is exposed to atmospheric pressure to extract the desalinated water. It is emptied again to extract water the following hour without affecting the system’s operating pressure. The results in the figures indicate stable values, which demonstrate reliability.
The effect of different seawater heights on the gain output ratio (GOR) is illustrated in Figure 9. Increasing the seawater height in the evaporation chamber negatively affects GOR. Decreasing productivity has a slight effect on the large shape with increased seawater height, while GOR significantly decreases. GOR is regarded as an important parameter used to measure overall system performance based on productivity and the quantity of system energy input, as can be expressed by Equation (17). The GOR results that can be achieved at 15 cm, 17 cm, 19 cm, and 21 cm are 1.16, 1, 0.90, and 0.83, respectively, at work operation values of Tsw = 80 °C and Tamb = 30 °C. In this study, the high value for productivity and GOR occurs at hsw = 15 cm. GOR can be expressed as [46]
where is the gain output ratio, represents the mass flow rate of freshwater (kg/s), and is the latent heat of vaporization (kJ/kg). is the amount of solar energy across the heat exchanger (kW). It can be calculated as follows:
where refers to the water mass flow rate of the heat exchanger (kg/s); Cpw represents the specific heat of water (kJ/kg·k); and and are the outlet and inlet of water temperature of the heat exchanger (°C), respectively.
Figure 9.
GOR variation with seawater height and seawater temperature at Tamb = 30 °C. (The figure colors of red, blue, green, and black indicate seawater temperatures of 50 °C, 60 °C, 70 °C, and 80 °C, respectively.).
The latent heat of water vaporization is calculated based on the practical equation, as mentioned in Refs. [15,47].
The percentage improvements resulting from lowering the seawater level in the evaporation chamber at temperatures in a range of 50 °C to 80 °C are summarized in Figure 10. Compared to hsw = 21 cm as a reference height, reducing the seawater level value by 6 cm (at hsw = 15 cm), when Tsw = 50 °C, productivity and GOR increase by 15.4% and 101.9%, respectively.
Figure 10.
Impact of decreased seawater height on the percentage of performance index for productivity and GOR at Tamb = 30 °C and reference hsw = 21 cm.
4.1.2. Impact of Ambient Temperature on Various Measurements
The impact of the ambient temperature on the evaporation chamber vapor temperature, the condenser vapor temperature, the temperature of freshwater, and the operating pressure is presented in Figure 11a–d. Figure 11a–c show that raising the ambient temperature results in a relatively slight increase in all measured temperatures. This is because the rising ambient temperature increases the water-condensing temperature in the condenser. Consequently, the steam temperature in the condenser and evaporation chamber increases.
Figure 11.
Various ambient temperatures with respect to the different measurements in the desalination system at hsw = 15 cm: (a) evaporation chamber vapor temperature, (b) condenser vapor temperature, (c) freshwater temperature, and (d) operating pressure.
The system’s operating pressure is directly linked to the rates of evaporation and condensation. It increases as the ambient temperature rises due to the decrease in the condensation rate caused by the convergence of the ambient and vapor temperatures (see Figure 11d).
4.1.3. Impact of Ambient Temperature on Various Parameters
Figure 12a–d demonstrate the effect of ambient temperature on productivity, Qin, GOR, and specific energy consumed (SEC). The effect of ambient temperature on productivity is shown in Figure 12a. Ambient temperature is considered a crucial climate index in assessing the system’s performance because the condenser used in the current system is naturally air-cooled. This means that the vapor condensation process is significantly influenced by the surrounding temperature, which determines the amount of freshwater production in this system. Freshwater production improves as the ambient temperature drops. This is a result of the increased temperature difference between the vapor and the surrounding air, which in turn raises the quantity of dissipated heat from the steam, leading to an increased amount of condensed water. Overall, the figure indicates that raising seawater temperature and decreasing surrounding temperature significantly affect the freshwater productivity.
Figure 12.
Impact of ambient temperature on performance indicators at hsw = 15 cm with different seawater temperatures: (a) productivity, (b) Qin, (c) GOR, and (d) SEC.
It can be seen from Figure 12b that the system energy input reduces regularly as the ambient temperature rises. When the ambient temperature increases, the temperature difference between the steam and the surroundings diminishes. This causes the steam to accumulate in the condenser without condensation. As a result, the steam flow from the evaporation chamber to the condenser is reduced, reducing steam production in the evaporation chamber. Consequently, less energy enters the system. According to experimental findings at Tamb = 28 °C, the energy input at Tsw = 50 °C, 60 °C, 70 °C, and 80 °C was calculated at 0.219 kW, 0.321 kW, 0.423 kW, and 0.524 kW, respectively.
As shown in Figure 12c, GOR is reduced because the decrease in productivity is substantial compared to the energy reduction. At the lowest operating ambient temperature of 28 °C, the highest GOR values were 0.94, 1.04, 1.12, and 1.20 at Tsw values of 50 °C, 60 °C, 70 °C, and 80 °C, respectively. Conversely, the SEC increases with the rise in ambient temperature, as illustrated in Figure 12d. Equation (20) illustrates that the SEC depends on the energy input of the system divided by productivity, as mentioned in Refs. [48,49].
When Tamb is reduced from 38 °C to 28 °C, the reduction ratios in SEC are 33.37%, 29%, 24.94%, and 22.51% at Tsw = 50 °C, 60 °C, 70 °C, and 80 °C, respectively. It is worth noting that a decreasing ambient temperature positively impacts productivity, GOR, and SEC.
Impact of reducing the ambient temperature on the performance index, as displayed in Figure 13. At conditions of hsw = 15 cm, Tsw = 80 °C, and Tamb = 38 °C as a reference, the enhancement ratios at an ambient temperature, reduced by a value of 10 °C (equal to Tamb = 28 °C) in productivity, GOR, and Qin, are increased by 40.2%, 22.5%, and 14.4%, respectively. In contrast, the SEC decreases in value by 18.4%.
Figure 13.
Effect of the decrease in ambient temperature on the performance indicators of the system at hsw =15 cm and Tsw = 80 °C at reference Tamb = 38 °C.
4.2. Exergy Analysis Results
In this section, the results of the exergy analysis of the low-pressure desalination systems are presented and discussed. The advantages of the exergy analysis are knowing the exergy destroyed, efficiency percentage, loss percentage, IR, IP, and FDR in each component system.
4.2.1. The Effect of Hourly Change on Exergy Analysis Parameters
The hourly variation in exergy destroyed in the evaporation chamber with different seawater heights is represented in Figure 14a–d. When the seawater height rises, the exergy destroyed will increase in the evaporation chamber. This increase is due to a greater quantity of system energy entering, which increases exergy loss. The rate of exergy destroyed increases as the seawater temperature increases. Hence, exergy destroyed in the evaporation chamber is more sensitive to the seawater temperature. The figure illustrates that the exergy loss values in the evaporation chamber are lower. The evaporation chamber is well insulated using glass wool, which results in reducing the exergy lost to the surrounding environment.
Figure 14.
Hourly change in exergy destroyed in the evaporation chamber with different seawater heights at Tamb = 30 °C.
Figure 15a–d present the effect of hourly variation on exergy destroyed in the condenser. Because the condenser is naturally air-cooled, and the majority of the condensation heat is lost to the environment, the exergy destroyed in the condenser is greater than the exergy lost in the evaporation chamber. It is worth mentioning that the low-pressure desalination system consumes a low amount of energy. Therefore, the amount of exergy destroyed is low. As shown in the figure, the maximum exergy loss is 80 W.
Figure 15.
Impact of hourly variation on exergy destroyed in the condenser with different seawater temperatures at Tamb = 30 °C.
4.2.2. Impact of Seawater Height on the Exergy Analysis Parameter
Figure 16 indicates the relation between IR in the condenser and the evaporation chamber with seawater height. Based on the equations from the Exergy Analysis Section, the IR in all components of the system is calculated. Knowing the IR in the system components provides useful information to improve system performance by addressing or mitigating deficiencies. As shown in the figure, the IR in the evaporation chamber increases with increasing seawater height. The IR is very high in the condenser, where it increases with seawater temperature while decreasing with increased seawater height. Therefore, the condenser is considered the main source of irreversibility due to the large amount of dissipated energy during the condensing process of the steam inside the condenser used to obtain freshwater.
Figure 16.
Impact of seawater height with IR of the condenser and evaporation chamber at Tamb = 30 °C.
Figure 17 demonstrates the impact of varying seawater height on the FDR of the evaporation chamber and condenser. The figure shows that FDR decreases in the evaporation chamber with rising seawater temperature. On the other side, FDR in the condenser increases with a rising seawater temperature, while it decreases with greater seawater height due to the reduction in the vapor temperature entering the condenser. The highest FDR in the condenser may reach more than 80%. This indicates that the condenser has the highest exergy consumption.
Figure 17.
Variation in seawater height with FDR of the evaporation chamber and condenser at Tamb = 30 °C.
The variation in seawater height regarding the IP of the condenser and evaporation chamber is illustrated in Figure 18. The IP of the condenser is very large. It is shown in the figures that the highest IP is for the condenser. This is because it is the element where a large amount of exergy is lost. Therefore, it is preferable to concentrate on enhancing the condenser performance. On the other hand, the evaporation chamber does not suffer from a major improvement process due to the low heat loss to the surrounding atmosphere and the good insulation using glass wool layers.
Figure 18.
Impact of seawater level in the evaporation chamber with IP of the condenser and evaporation chamber at Tamb = 30 °C.
Figure 19 illustrates the exergy ratio of the evaporation chamber with the seawater level. The efficiency and loss ratio were evaluated separately for each component for a seawater height of 15 cm to 21 cm. At hsw = 15 cm, the exergy efficiency value of the evaporation chamber rises depending on the elevation in the seawater temperature and reaches a value of 87.12%, and the loss value decreases until it reaches a percentage of 12.88% at a temperature of Tsw = 80 °C. As viewed in Figure 20, the exergy efficiency ratio in the condenser increases with increasing seawater temperature, but this increase is very small. The exergy destroyed ratio in the condenser is very large and can reach 96.22% due to the amount of condensation heat in the condenser being expelled into the surroundings. An exergy analysis for a low-temperature system with a naturally air-cooled condenser was carried out by Gude et al. [16]. Their results indicated that the greatest amount of exergy was destroyed in the condenser due to the latent heat of condensation dissipation in the water vapor into the surroundings. The exergy loss ratio in the condenser reached 98.69%. This conclusion is entirely consistent with the findings of the current investigation.
Figure 19.
Variation in seawater height with ratio efficiency and the destruction of the evaporation chamber component at Tamb = 30 °C.
Figure 20.
Effect of seawater height on the ratio of destruction and efficiency of the condenser component at Tamb = 30 °C.
Figure 21 illustrates the effect of seawater height on exegetic efficiency. Exergetic efficiency is determined using Equation (16). Increased seawater temperature is a significant factor in enhancing exergetic efficiency behavior. At hsw = 15 cm and Tamb = 30 °C, the exergetic efficiency values are recorded as 0.92%, 1.85%, 2.64%, and 3.42% at Tsw = 50 °C, 60 °C, 70 °C, and 80 °C, respectively.
Figure 21.
Variation in exergetic efficiency with seawater height at Tamb = 30 °C. (Seawater temperatures of 50 °C, 60 °C, 70 °C, and 80 °C are indicated by the colors red, blue, green, and black, respectively.).
Figure 22a,b present a summary of performance indicators for both the evaporation chamber and condenser. Several performance metrics were evaluated for each component separately within the exergy analysis system, including exergy loss, exergy efficiency, IR, and FDR. As shown in Figure 22a, compared to hsw = 21 cm, decreasing the seawater height by 6 cm resulted in evaporation chamber parameters of 54%, 40.7%, and 41.2% in exergy loss, IR, and FDR, respectively. In contrast, exergy efficiency increased by 11.6%. As seen in Figure 22b, reducing the seawater height by 6 cm causes a reduction in exergy loss in the condenser of 13.2%. On the other hand, IR, FDR, and exergy efficiency increased by 28.8%, 11.8%, and 10.9%, respectively, compared to hsw = 21 cm.
Figure 22.
Decrease in seawater height with the percentage of performance index of the evaporation chamber and condenser at Tsw = 80 °C and Tamb = 30 °C and reference hsw = 21 cm. (Decrease in seawater height with many of the exergy parameters at Tsw = 80 °C, Tamb = 30 °C, and reference hsw = 21 cm, (a) the percentage of performance index in evaporation chamber; (b) the percentage of performance index in condenser).
4.2.3. Impact of Ambient Temperature on Exergy Analysis Parameters
The exergy destroyed increases because of the increasing difference between the exergy entering and leaving the system, as indicated in Equation (5). It expresses the amount of energy lost from the system (irreversibility). The impact of ambient temperature and exergy destroyed in both the condenser and evaporation chamber is depicted in Figure 23a,b. As can be seen in Figure 23a, some factors increase exergy destroyed in the evaporation chamber, such as seawater and ambient temperature. As ambient temperature rises, the evaporation chamber steam temperature also elevates, resulting in a corresponding rise in exergy destroyed. An important factor in reducing exergy destroyed in an evaporation chamber is good insulation, which prevents heat loss to the surrounding atmosphere. The exergy destroyed in the evaporation chamber reaches its maximum value at a Tamb = 38 °C, and a Tsw of 80 °C is 20 W. On the other side, the maximum exergy destroyed in the condenser occurs at a Tamb = 28 °C and a Tsw of 80 °C, which is 70 W, as shown in Figure 23b. Lowering the ambient temperature increases the exergy content of the vapor entering the condenser, which leads to a rise in exergy destroyed in it.
Figure 23.
Impact of ambient temperature on exergy destroyed in the condenser and the evaporation chamber at hsw = 15 cm. (Impact of ambient temperature with different seawater temperatures at hsw = 15 cm, (a) exergy destroyed in evaporation chamber; (b) exergy destroyed in condenser.).
The relationship between IR in the condenser and the evaporation chamber with the ambient temperature is illustrated in Figure 24. IR in the evaporation chamber is more sensitive to an elevation in ambient temperature. This is due to the increased vapor temperature formed and the rise in the evaporation chamber losses. In contrast, in the condenser, a rise in ambient temperature reduces IR due to the reduced exergy of the water produced at the higher ambient temperature.
Figure 24.
Variation in IR in the evaporation chamber and condenser with ambient temperature at hsw = 15 cm.
From an exergy analysis perspective, FDR reflects the amount of energy consumed in each component individually. Figure 25 shows the correlation between ambient temperature and FDR in the condenser and the evaporation chamber. FDR has more energy consumption in the evaporation chamber at Tamb = 38 °C. Conversely, energy consumption in the condenser is lower due to the reduced exergy loss from the desalinated water at higher ambient temperatures.
Figure 25.
Impact of ambient temperature on FDR for the evaporation chamber and condenser at hsw = 15 cm.
IP is one of the most crucial parameters in exergy analysis. It was studied in an evaporation chamber and a condenser with varying ambient temperatures, as seen in Figure 26a,b. IP depends on the exergy destroyed, as shown in Equation (13). With an increase in ambient temperature, the steam temperature in the evaporation chamber increases. Thus, the exergy destroyed raises the evaporation chamber. Therefore, it requires improvement. Figure 26a shows that the improvement values are very small in the evaporation chamber and do not exceed 10 W. As observed in Figure 26b, IP increases after reducing the ambient temperature. This is due to the increased temperature difference between the condenser vapor and the ambient temperature, leading to more exergy destroyed. Consequently, there is an increased need for improvement. The maximum IP in the condenser reaches 70 W.
Figure 26.
Effect of ambient temperature on IP in the evaporation chamber and condenser at hsw = 15 cm. (Effect of ambient temperature under different seawater temperatures at hsw = 15 cm, (a) IP in evaporation chamber; (b) IP in condenser.).
Exergetic efficiency is employed to measure the overall system performance from a thermodynamic perspective. Figure 27 illustrates the impact of ambient temperature on exergetic efficiency. According to the second law of thermodynamics, exergetic efficiency is determined by the exergy production of desalinated water and the exergy heat input in the system, as illustrated in Equation (16). The exergetic efficiency index increases significantly with increasing seawater temperature. This is due to the large increase in value of freshwater production exergy compared to the increase in exergy entering the system. The figure also notes that exergetic efficiency gradually decreases as the ambient temperature increases. This is the result of the convergence of temperatures between the vapor in the condenser and the ambient temperature. Consequently, the exergy of freshwater output decreases. Therefore, its exergetic efficiency value decreases. At the operation conditions hsw = 15 cm, Tsw = 80 °C, and Tamb = 28 °C, the exergetic efficiency reaches a maximum value of 3.48%. Combining the highest seawater temperature with the lowest ambient temperature resulted in the highest exergetic efficiency because the exergy of productivity exceeded the system’s energy input exergy.
Figure 27.
Variation in exegetic efficiency with ambient temperature at different seawater temperatures at hsw = 15 cm. (Red, blue, green, and black colors represent Tsw of 50 °C, 60 °C, 70 °C, and 80 °C, respectively.).
5. Economic Analysis
The economic cost of freshwater productivity when using the proposed desalination system must be calculated to assess its viability in the desalination market. Economic analysis is an important indicator that provides a comprehensive view of the system’s effectiveness (meaning that it combines both the experimental performance of the unit represented by productivity and the economic principles represented by the total system cost). The capital cost (P) of constructing the low-pressure desalination system depends on calculating the cost of all system components and the fabrication cost, as shown in Table 2.
Table 2.
Cost of the proposed system components.
Furthermore, the economic analysis also aims to determine the period required to recover the costs of the experimental setup (payback period). The Egyptian market cost of distilled water (EMCDW) is approximately 0.53 USD/kg. Table 3 details the cost calculation method, the net profit (NP), the payback period (PP), and the various factors using economic analysis for the proposed system, as illustrated in Refs. [19,31,50]. The device operates for eight hours a day. It begins at 9 a.m. and finishes at 5 p.m. local time. Based on Egypt’s climate conditions, the number of device operation days in a year (Nday) for the low-temperature desalination device is expected to be 340 days, corresponding to the sunrise period [51].
Table 3.
Cost analysis of the suggested system at hsw = 15 cm and Tamb = 30 °C.
M is the overall annual freshwater productivity of the system. The quantities of drinking water acquired annually from the low-pressure desalination device at different seawater temperatures (50 °C, 60 °C, 70 °C, and 80 °C) are found to be 802.4 kg/year, 1338 kg/year, 1931 kg/year, and 2600 kg/year, respectively. According to the findings of the economic analysis, the present system’s freshwater costs 0.042 USD/kg, and it can recoup its initial cost in 183 days (almost 6.5 months). This demonstrates the effectiveness of the system in recovering initial costs within a short period of operation.
PP relies on the values of EMCDW and Nday. Therefore, several EMCDW and Nday values were assumed to make the results easier to generalize. The relationship between the variance in PP with EMCDW and Nday is plotted in Figure 28. Economic analysis indicates that PP is inversely proportional to EMCDW and directly proportional to Nday. At Nday = 340 days and EMCDW = 0.53 USD/kg, decreasing Nday by 20 days means that PP reduces by 5.87%. Conversely, when Nday rises by 20 days, PP increases by the same amount. At Nday = 340 days, PP rises by 14% when EMCDW is lowered from 0.53 USD/kg to 0.47 USD/kg. On the other hand, PP drops by 11% when it rises from 0.53 USD/kg to 0.59 USD/kg.
Figure 28.
Variation in PP with changes in EMCDW and Nday under the following conditions: hsw = 15 cm, Tsw = 80 °C, and Tamb = 30 °C.
6. Environmental Analysis
One of the most significant contemporary trends is reducing carbon dioxide (CO2) emissions into the environment. Therefore, the proposed system was designed to operate using solar energy to save the environment. In this work, an environmental analysis was conducted by calculating the number of CO2 emissions that were reduced during the system operation. The total amount of CO2 reduced per year in tons by the proposed system is calculated, as written in Ref. [52].
where refers to the environmental parameter. EF is the emission factor value of the Egyptian grid, which is 0.52 kgCO2/kWh [53]. denotes the system annual energy output in the year. It is defined as the product of annual productivity and the latent heat for evaporation, calculated as follows [54]:
where M is the overall annual freshwater productivity of the system.
7. Enviroeconomic Analysis
Based on the price of CO2 emitted over the lifetime of the desalination system, an enviroeconomic analysis is performed. The following formula can be used to calculate it [55,56].
where and refer to the carbon price and enviroeconomic parameter, respectively. Prior research has employed an average carbon cost of 14.5 USD/tonCO2 [52,55].
The cost and quantity of CO2 mitigation from the current study are calculated based on the cost of the Egyptian electricity grid, as displayed in Table 4. Table 4 displayed the results of CO2 mitigations at Tsw of 50 °C, 60 °C, 70 °C, and 80 °C, which are 4.14, 6.83, 9.76, and 13 tons of CO2/year, respectively. On the other hand, the costs of CO2 saved for the system are 60.05 USD/year, 99.12 USD/year, 141.5 USD/year, and 188.5 USD/year at Tsw of 50 °C, 60 °C, 70 °C, and 80 °C, respectively. According to the table’s findings, an environmental and enviroeconomic index is the most effective in removing CO2 emissions at Tsw = 80 °C.
Table 4.
Environmental and enviroeconomic parameters are estimated for the proposed system based on Egyptian electricity grid costs at hsw = 15 cm and Tamb = 30 °C.
Other environmental and enviroeconomic factors that must be considered in desalination systems include waste brine disposal and the disposal of the unit at the end of its service life. Because the risk posed by these factors leads to increased costs and environmental damage. There are several effective methods for disposing of waste brine from desalination systems, including reusing the brine solution for solar-pond evaporation, discharging brine to saline surface water, and placing brine in an existing region with extremely saline groundwater [57]. At the end of operational lifetime, most device components can be recycled, including aluminum fins, copper tubes, cylinders made of cast iron, and metal stand structures. This contributes to minimizing environmental burden and to the lower economic burden.
8. Comparison of the Proposed System with Other Desalination Systems
To evaluate the effectiveness of the suggested desalination system in the desalination market, a comparison was made with different desalination systems. A comparison of the current system’s performance with different desalination systems is presented in Table 5. In Table 5, many desalination methods are discussed, such as solar still (SS), humidification–dehumidification desalination (HDH), multi-effect distillation (MED), adsorption desalination systems (ADSs), and membrane distillation (MD). This comparison is considered unfair due to the differences in several factors, such as device size, operating conditions, power source, design differences, and component costs, in different countries. However, it aims to determine the compatibility of the current study with other systems discussed in numerous previous studies. These are the strengths and weaknesses of the proposed system compared to other systems. The table’s results show that the current system outperformed the HDH and SS systems in terms of exergetic efficiency. On the other hand, it is significantly lower in terms of productivity than the MSF, MD, and MED systems.
Table 5.
Comparing the performance of the proposed system with different desalination systems.
9. Recommendations and Future Work
The following recommendations and future work aim to contribute to the enhancement of the performance of the low-pressure desalination device, in addition to opening new avenues and points of research in this technology. Future work can be summarized as follows:
- Researchers have not studied the impact of changing the condenser size on the unit performance experimentally. The large size of the condensing chamber leads to a rise in performance and system efficiency.
- The water-spraying method should be used instead of placing a quantity of water in the evaporator for low-pressure desalination. The spraying method makes it easier to convert water droplets into steam.
- An ultrasonic device should be used in the water vaporization process in the evaporator.
- The effect of changing the spacing between the fins of a natural air condenser on the operation conditions of a desalination unit has not been studied before.
- A comprehensive economic and environmental analysis of the utilization of highly concentrated brine was generated for the desalination system.
- Numerous suggestions can be made to improve condenser performance through design optimization and operating condition modification. Optimized condenser design includes the following: wavy fins and changing the distance between the fins. Modification of condenser operating conditions includes recovering condenser waste heat for feedwater preheating or using a fan on the condenser and moving hot air around in other systems.
10. Conclusions
An exergy, environmental, and economic analysis of a low-pressure desalination unit with a natural air-cooling condenser powered by solar energy was comprehensively performed. Many practical parameters affecting the system’s performance were studied, including the temperature and height of seawater in the evaporation chamber and the operating time of the experiment. Ambient temperature is considered one of the most crucial climatic factors, greatly affecting the efficiency of naturally cooled air condensers. Therefore, it has been discussed in more detail. For the exergy analysis, many variables were studied, like the exergy destroyed in the condenser and evaporation chamber; IR, IP, and FDR; the percentage of destruction and the efficiency of all components in the system; and the exergetic efficiency. This research highlighted the possibility of using exergy analysis as an important tool to improve system performance. The important observations are summarized in the following points:
- At hsw = 15 cm and Tamb = 30 °C, the system’s productivity is 295 g/h, 495 g/h, 710 g/h, and 956 g/h at seawater temperatures of 50 °C, 60 °C, 70 °C, and 80 °C, respectively. When seawater temperatures increase, water molecules move more. Consequently, the cohesive force of water molecules decreases. Therefore, the ease of converting liquid water into a vapor state increases productivity.
- The GOR findings that can be achieved at 15 cm, 17 cm, 19 cm, and 21 cm are 1.16, 1, 0.90, and 0.83, respectively, under the conditions Tsw = 80 °C and Tamb = 30 °C. The GOR value depends on productivity and energy input. As seawater levels rise, productivity decreases, while energy input increases, leading to a downward decline in the GOR index.
- Under work conditions of hsw = 15 cm, Tsw = 80 °C, and Tamb = 38 °C as a reference, when an ambient temperature is reduced by a value of 10 °C (equal to Tamb = 28 °C), the enhancement ratios in productivity, GOR, and Qin are increased by 40.2%, 22.5%, and 14.4%, respectively, while SEC decreases in value by 18.4%.
- The exergetic efficiency increases with increasing seawater temperature, and it rises with decreasing ambient temperature. Under the conditions hsw = 15 cm, Tsw = 80 °C, and Tamb = 28 °C, the highest exergetic efficiency reaches 3.48%. The exergetic efficiency is based on the freshwater exergy and the exergy of the power entering the system. It achieved optimal conditions at both the highest seawater temperature and the lowest ambient temperatures and seawater height. This is because it achieves the highest exergy production compared to the exergy power input.
- Exergy analysis aims to find the causes of exergy destruction in components and improve running conditions and component design. Therefore, it was concluded that the highest improvement rate takes place in the condenser, and the design can be improved to benefit from the greatest amount of wasted heat.
- Based on the economic analysis of the present unit, the cost of freshwater productivity was calculated to be 0.042 USD/kg. Moreover, the initial cost recovery period of the device is approximately 183 days (almost 6.5 months) when it has a lifetime of 15 years.
- The findings of the environmental and enviroeconomic analyses demonstrate that the maximum amount and cost of CO2 that can be removed from the environment using this proposed system are 13 tons of CO2/year and 188.5 USD/year, respectively.
Author Contributions
Conceptualization and supervision A.S.A.M., M.S.A. and H.A.M.; reviewing and editing the manuscript, A.S.A.M. and M.S.A.; writing, data acquisition and analysis, H.A. and A.G.S. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
Data will be made available on request.
Conflicts of Interest
The authors declare no conflicts of interest.
Nomenclature
| a | Accuracy | fw | Freshwater |
| Specific heat of water (kJ/kg·k) | h | Heat exchanger | |
| Exergy rate (kW) | i | Component | |
| System energy output in a year (kWh) | in | Inlet | |
| Physical flow exergy (kW) | out | Outlet | |
| h | Enthalpy (kJ/kg) | sw | Seawater |
| hfg | Latent heat of vaporization (kJ/kg) | sw, feed | Feed seawater |
| hsw | Seawater height (cm) | va | Vapor |
| M | Amount of freshwater throughout the year | w | Water |
| mass rate (kg/s) | |||
| N | Number of repeated measurements | Abbreviations | |
| n | Life time, (year) | AC | Total annual cost |
| Nday | Number of device operation days in a year | AMC | Annual maintenance cost |
| Q | Amount of heat rate (kW) | ASV | Annual salvage value |
| Energy input to the system (kW) | C | Condenser | |
| s | Entropy (kJ/kg·k) | CC | Current cost |
| T | Temperature (°C) | CRF | Capital recovery factor |
| U | Uncertainty for Type A | CPL | Cost per kilogram |
| u | Standard uncertainty of devices | EC | Evaporation chamber |
| W | Work (kW) | EF | Emission factor |
| EMCDW | Egyptian market cost of distilled water | ||
| Greek letters | FAC | Fixed annual cost | |
| Exergy efficiency (%) | FDR | Fuel depletion ratio | |
| uncertainty for Type B | GOR | Gain output ratio | |
| Environmental parameter (ton CO2/year) | IP | Improvement potential | |
| Enviroeconomic parameter (USD/year) | IR | Irreversibility ratio | |
| Carbon price (USD) | NP | Net profit | |
| P | Capital cost | ||
| Subscript | PP | Payback period | |
| amb | Ambient | SD | Standard deviation |
| br | Brin | SEC | Specific energy consumption |
| d | Destroyed | SFF | Sinking fund factor |
References
- Ahmed, M.S.; Mohamed, A.S.A.; Mohamed, H.A.; Abdelaal, M.R.; Abbady, H. A review of vacuum solar desalination powered by renewable energy: Recent trends. J. Clean. Prod. 2023, 428, 139244. [Google Scholar] [CrossRef] [Scilit]
- Mahala, T.; Sharma, N. Experimental investigations of a novel solar still with heat storage materials-energy, exergy, economic and environmental analyses. Desalination 2024, 578, 117467. [Google Scholar] [CrossRef] [Scilit]
- Darawsheh, I.; Islam, M.D.; Banat, F. Experimental characterization of a solar powered MSF desalination process performance. Therm. Sci. Eng. Prog. 2019, 10, 154–162. [Google Scholar] [CrossRef] [Scilit]
- Setyawan, E.Y.; Ambarita, H. A preliminary field test of a natural vacuum solar desalination unit using hybrid solar collector. AIP Conf. Proc. 2018, 1984, 020014. [Google Scholar] [CrossRef] [Scilit]
- Gude, V.G.; Nirmalakhandan, N. Desalination at low temperatures and low pressures. Desalination 2009, 244, 239–247. [Google Scholar] [CrossRef] [Scilit]
- Rabaia, M.K.H.; Abdelkareem, M.A.; Sayed, E.A.; Elsaid, K.; Chae, K.-J.; Wilberforce, T.; Olabi, A.G. Environmental impacts of solar energy systems: A review. Sci. Total Environ. 2021, 754, 141989. [Google Scholar] [CrossRef] [Scilit]
- Falah, S.; Hachim, D.M.; Abd Al-wahid, W.A. The performance of cylindrical solar still with hemispherical dome using circular fins in basin. Int. J. Thermofluids 2025, 25, 101026. [Google Scholar] [CrossRef] [Scilit]
- Alhaj, M.; Tahir, F.; Al-Ghamdi, S.G. Life-cycle environmental assessment of solar-driven Multi-Effect Desalination (MED) plant. Desalination 2022, 524, 115451. [Google Scholar] [CrossRef] [Scilit]
- Yadav, K.; Gudjonsdottir, M.; Axelsson, G.; Ómarsdóttir, M.; Sircar, A.; Shah, M.; Yadav, A. Geothermal-solar integrated Multistage Flash Distillation Cogeneration system: A cleaner and sustainable solution. Desalination 2023, 566, 116897. [Google Scholar] [CrossRef] [Scilit]
- Anand, B.; Shankar, R.; Murugavelh, S.; Rivera, W.; Midhun Prasad, K.; Nagarajan, R. A review on solar photovoltaic thermal integrated desalination technologies. Renew. Sustain. Energy Rev. 2021, 141, 110787. [Google Scholar] [CrossRef] [Scilit]
- Abbady, H.; Mohamed, A.S.A.; Ahmed, M.S.; Hassan, H. Performance enhancement of a humidification-dehumidification seawater desalination system. Environ. Sci. Water Res. Technol. 2020, 6, 3276–3292. [Google Scholar] [CrossRef] [Scilit]
- Gao, Y.; Lu, L. Comparative study on solar-driven combined liquid desiccant regeneration and freshwater production systems integrated with membrane distillation: Energy, exergy, and economic analysis. Desalination 2025, 600, 118476. [Google Scholar] [CrossRef] [Scilit]
- Wei, M.; Xiang, J.; Ye, H.; Zheng, H.; Wang, K.; Chen, J. Using water-filling and air-releasing to design a natural vacuum solar desalination system. Sol. Energy 2021, 220, 598–607. [Google Scholar] [CrossRef] [Scilit]
- Wang, L.; Zheng, H.; Zhao, Y.; Ma, X. Solar-driven natural vacuum desalination system with inner condenser. Appl. Therm. Eng. 2021, 196, 117320. [Google Scholar] [CrossRef] [Scilit]
- Abdel Dayem, A.M. Innovative solar natural vacuum desalination system. Case Stud. Therm. Eng. 2023, 44, 102881. [Google Scholar] [CrossRef] [Scilit]
- Gude, V.G.; Nirmalakhandan, N.; Deng, S.; Maganti, A. Desalination at low temperatures: An exergy analysis. Desalin. Water Treat. 2012, 40, 272–281. [Google Scholar] [CrossRef] [Scilit]
- Bilgil, A.; Hırlakoğlu, B. An experimental study on desalination at vacuum environment under low pressure and low condensation temperatures. Desalination 2017, 411, 9–18. [Google Scholar] [CrossRef] [Scilit]
- Sriram, V.; Samuel Hansen, R.; Kalidasa Murugavel, K. Experimental study an a low pressure solar still. Appl. Sol. Energy 2013, 49, 137–141. [Google Scholar] [CrossRef] [Scilit]
- Patel, S.K.; Singh, D.; Devnani, G.L.; Sinha, S.; Singh, D. Potable water production via desalination technique using solar still integrated with partial cooling coil condenser. Sustain. Energy Technol. Assess. 2021, 43, 100927. [Google Scholar] [CrossRef] [Scilit]
- Ibrahim, A.G.M.; Allam, E.E.; Elshamarka, S.E. A modified basin type solar still: Experimental performance and economic study. Energy 2015, 93, 335–342. [Google Scholar] [CrossRef] [Scilit]
- Morad, M.M.; El-Maghawry, H.A.M.; Wasfy, K.I. A developed solar-powered desalination system for enhancing fresh water productivity. Sol. Energy 2017, 146, 20–29. [Google Scholar] [CrossRef] [Scilit]
- Ibrahim, A.G.M.; Dincer, I. A solar desalination system: Exergetic performance assessment. Energy Convers. Manag. 2015, 101, 379–392. [Google Scholar] [CrossRef] [Scilit]
- Hosseini, A.; Banakar, A.; Gorjian, S. Development and performance evaluation of an active solar distillation system integrated with a vacuum-type heat exchanger. Desalination 2018, 435, 45–59. [Google Scholar] [CrossRef] [Scilit]
- Mohamed, A.S.A.; Shahdy, A.G.; Mohamed, H.A.; Ahmed, M.S. A comprehensive review of the vacuum solar still systems. Renew. Sustain. Energy Rev. 2023, 184, 113572. [Google Scholar] [CrossRef] [Scilit]
- Al-Obaidi, M.A.; Rashid, F.L.; Abdulhadi, H.A.; Al-Musawi, S.S.; Saif, M. A Review of Vacuum-Enhanced Solar Stills for Improved Desalination Performance. Sustainability 2025, 17, 9535. [Google Scholar] [CrossRef] [Scilit]
- Ibrahim, A.G.M.; Elshamarka, S.E. Performance study of a modified basin type solar still. Sol. Energy 2015, 118, 397–409. [Google Scholar] [CrossRef] [Scilit]
- Abbady, H.; Ahmed, M.S.; Hassan, H.; Mohamed, A.S.A. Experimental study on the desalination system using humidification-dehumidification technology. Mater. Sci. Forum 2020, 1008, 177–185. [Google Scholar] [CrossRef] [Scilit]
- Senapati, J.R.; Dash, S.K.; Roy, S. Numerical investigation of natural convection heat transfer from vertical cylinder with annular fins. Int. J. Therm. Sci. 2017, 111, 146–159. [Google Scholar] [CrossRef] [Scilit]
- Esfahani, J.A.; Rahbar, N.; Lavvaf, M. Utilization of thermoelectric cooling in a portable active solar still—An experimental study on winter days. Desalination 2011, 269, 198–205. [Google Scholar] [CrossRef] [Scilit]
- Mohamed, A.S.A.; Shahdy, A.G.; Salem Ahmed, M. Investigation on solar humidification dehumidification water desalination system using a closed-air cycle. Appl. Therm. Eng. 2021, 188, 116621. [Google Scholar] [CrossRef] [Scilit]
- Hassan, H.; Ahmed, M.S.; Fathy, M. Experimental work on the effect of saline water medium on the performance of solar still with tracked parabolic trough collector (TPTC). Renew. Energy 2019, 135, 136–147. [Google Scholar] [CrossRef] [Scilit]
- Mohamed, A.S.A.; Ahmed, M.S.; Shahdy, A.G. Theoretical and experimental study of a seawater desalination system based on humidification-dehumidification technique. Renew. Energy 2020, 152, 823–834. [Google Scholar] [CrossRef] [Scilit]
- Pandey, N.; Naresh, Y. Heat transfer, and Energy, Exergy, Economic, Exergoeconomic, Exergoenvironment, Enviroeconomic (6E) analysis of a modified pyramidal solar still with pulsating heat pipe, PCM and fins: An experimental investigation. Desalination 2025, 609, 118850. [Google Scholar] [CrossRef] [Scilit]
- Joint Committee for Guides in Metrology (JCGM). Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement; JCGM: Paris, France, 2008; Volume 100. [Google Scholar]
- Kirkup, L.; Frenkel, R.B. An Introduction to Uncertainty in Measurement: Using the GUM (Guide to the Expression of Uncertainty in Measurement); Cambridge University Press: Cambridge, UK, 2006. [Google Scholar]
- Hepbasli, A. A key review on exergetic analysis and assessment of renewable energy resources for a sustainable future. Renew. Sustain. Energy Rev. 2008, 12, 593–661. [Google Scholar] [CrossRef] [Scilit]
- Muthusamy, C.; Srithar, K. Energy and exergy analysis for a humidification–dehumidification desalination system integrated with multiple inserts. Desalination 2015, 367, 49–59. [Google Scholar] [CrossRef] [Scilit]
- Kerme, E.D.; Orfi, J.; Fung, A.S.; Salilih, E.M.; Khan, S.U.D.; Alshehri, H.; Ali, E.; Alrasheed, M. Energetic and exergetic performance analysis of a solar driven power, desalination and cooling poly-generation system. Energy 2020, 196, 117150. [Google Scholar] [CrossRef] [Scilit]
- Çengel, Y.A.; Boles, M.A. Thermodynamics: An Engineering Approach, 8th ed.; McGraw-Hill: New York, NY, USA, 2004. [Google Scholar]
- Ogaili, H.H.; Khalilarya, S.; Chitsaz, A. Mojaver, Energy, exergy, and economic performance analysis of integrated parabolic trough collector with organic rankine cycle and ejector refrigeration cycle. Energy Convers. Manag. X 2025, 25, 100843. [Google Scholar]
- Moran, M.J.; Shapiro, H.N. Fundamentals of Engineering Thermodynamics, 5th ed.; John Wiley & Sons, Inc.: Hoboken, NJ, USA, 2010. [Google Scholar]
- Lawal, D.U.; Zubair, S.M.; Antar, M.A. Exergo-economic analysis of humidification-dehumidification (HDH) desalination systems driven by heat pump (HP). Desalination 2018, 443, 11–25. [Google Scholar] [CrossRef] [Scilit]
- Mistry, K.H.; McGovern, R.K.; Thiel, G.P.; Summers, E.K.; Zubair, S.M.; Lienhard, V.J.H. Entropy generation analysis of desalination technologies. Entropy 2011, 13, 1829–1864. [Google Scholar] [CrossRef] [Scilit]
- Sharqawy, M.H.; Lienhard, J.H.; Zubair, S.M. Thermophysical properties of seawater: A review of existing correlations and data. Desalin. Water Treat. 2010, 16, 354–380. [Google Scholar] [CrossRef] [Scilit]
- Esmaeilion, F.; Ahmadi, A.; Hoseinzadeh, S.; Aliehyaei, M.; Makkeh, S.A.; Astiaso Garcia, D. Renewable energy desalination; a sustainable approach for water scarcity in arid lands. Int. J. Sustain. Eng. 2021, 14, 1916–1942. [Google Scholar] [CrossRef] [Scilit]
- Zhani, K. Solar desalination based on multiple effect humidification process: Thermal performance and experimental validation. Renew. Sustain. Energy Rev. 2013, 24, 406–417. [Google Scholar] [CrossRef] [Scilit]
- El-Dessouky, H.T.; Ettouney, H.M. Fundamentals of Salt Water Desalination; Elsevier: Amsterdam, The Netherlands, 2002. [Google Scholar]
- Rahimi-Ahar, Z.; Hatamipour, M.S. Performance evaluation of a solar and vacuum assisted multi-stage humidification-dehumidification desalination system. Process Saf. Environ. Prot. 2021, 148, 1304–1314. [Google Scholar] [CrossRef] [Scilit]
- Shafieian, A.; Azhar, M.R.; Khiadani, M.; Sen, T.K. Performance improvement of thermal-driven membrane-based solar desalination systems using nanofluid in the feed stream. Sustain. Energy Technol. Assess. 2020, 39, 100715. [Google Scholar] [CrossRef] [Scilit]
- El-Sebaey, M.S.; Ellman, A.; Hegazy, A.; Essa, F.A. Experimental study with thermal and economical analysis for some modifications on cylindrical sector and double slope, single basin solar still. Case Stud. Therm. Eng. 2023, 49, 103310. [Google Scholar] [CrossRef] [Scilit]
- Abdelaziz, G.B.; El-Said, E.M.S.; Bedair, A.G.; Sharshir, S.W.; Kabeel, A.E.; Elsaid, A.M. Experimental study of activated carbon as a porous absorber in solar desalination with environmental, exergy, and economic analysis. Process Saf. Environ. Prot. 2021, 147, 1052–1065. [Google Scholar] [CrossRef] [Scilit]
- Hassan, H.; Yousef, M.S.; Ahmed, M.S.; Fathy, M. Energy, exergy, environmental, and economic analysis of natural and forced cooling of solar still with porous media. Environ. Sci. Pollut. Res. 2020, 27, 38221–38240. [Google Scholar] [CrossRef] [Scilit]
- Mousa, M.M.; Saleh, S.M.; Samy, M.M.; Barakat, S. Optimizing grid-tied hybrid renewable systems for EV charging in Egypt: A techno-economic analysis. Results Eng. 2025, 27, 106103. [Google Scholar] [CrossRef] [Scilit]
- Maurya, A.; Kumar, R.; Gupta, A.; Ahmadi, M.H.; Al-Bahrani, M. Energy, exergy, economic, exergoeconomic, exergoenvironment, and enviroeconomic (6E) analysis of solar stills—A critical review. Energy Sci. Eng. 2024, 12, 267–283. [Google Scholar] [CrossRef] [Scilit]
- Elbar, A.R.A.; Yousef, M.S.; Hassan, H. Energy, exergy, exergoeconomic and enviroeconomic (4E) evaluation of a new integration of solar still with photovoltaic panel. J. Clean. Prod. 2019, 233, 665–680. [Google Scholar] [CrossRef] [Scilit]
- Shoeibi, S.; Rahbar, N.; Esfahlani, A.A.; Kargarsharifabad, H. A comprehensive review of Enviro-Exergo-economic analysis of solar stills. Renew. Sustain. Energy Rev. 2021, 149, 111404. [Google Scholar] [CrossRef] [Scilit]
- Panagopoulos, A.; Haralambous, K.-J.; Loizidou, M. Desalination brine disposal methods and treatment technologies—A review. Sci. Total Environ. 2019, 693, 133545. [Google Scholar] [CrossRef] [Scilit]
- Shamet, O.; Qureshi, B.A.; Antar, M. Energy and exergo-economic analysis of a parallel feed multi-effect system integrated with humidification–dehumidification system for brine recovery. Energy Environ. 2025, 36, 1775–1796. [Google Scholar] [CrossRef] [Scilit]
- Ali, E.S.; Alsaman, A.S.; Askalany, A.A.; Farid, A.M.; Ghazy, M.; Mansour, R.B.; Ben-Mansour, R.; El-Maghlany, W.M.; Tawfik, M.H.M. Cost analysis for solar-powered adsorption desalination-cooling system utilizing improved Maxsorb III adsorbents under Egypt weather conditions. Alexandria Eng. J. 2025, 126, 341–357. [Google Scholar] [CrossRef] [Scilit]
- Farhadi, F.; Deymi-Dashtebayaz, M.; Tayyeban, E. Studying a Multi-Stage Flash Brine Recirculation (MSF-BR) System Based on Energy, Exergy and Exergoeconomic Analysis. Water 2022, 14, 3108. [Google Scholar] [CrossRef] [Scilit]
- Okati, V.; Moghadam, A.J.; Farzaneh-Gord, M.; Moein-Jahromi, M. Thermo-economical and environmental analyses of a Direct Contact Membrane Distillation (DCMD) performance. J. Clean. Prod. 2022, 340, 130613. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.