Abstract

Supply–demand balance in wind–solar dominant energy transition is challenged by the volatility of wind–solar power. Complementarity of wind–solar power has been introduced to suppress this volatility. Although multiple indices have been developed to quantify complementarity, a quantitative index with explicit physical meaning remains lacking. Additionally, complementarity’s temporal stability, which is imperative for wind–solar site selection, is unclear. In this study, these knowledge gaps are closed through developing a Daily Complementarity Index of wind–solar generation (DCI) and a nuanced national assessment of complementarity in China. The results of the comparison of our index with existing indices and site validation confirm the reasonability of the DCI and its improvements in interpretability. The average DCI of China ranges from 0.06 to 0.88, with a pronounced low-DCI zone across the Sichuan Basin and Chongqing municipality, and a high–DCI zone along the Three-North Shelterbelt. Temporally, the complementarity of wind–solar power in China follows a slight increase trend (3.96 × 10−5 year−1), with evident seasonal characteristics, in which the highest and lowest are 0.37 and 0.17, respectively. This study introduces an effective tool for quantifying complementarity, and these findings can offer valuable reference for China’s renewable energy transition.

1. Introduction

Intensifying extreme weather events and projected fossil energy crisis necessitate a sustainable development pathway [1]. Wind–solar dominant energy transition is a prospective strategy for mitigating climate change while meeting sustainable power supply [2,3]. However, the intrinsic volatility of wind–solar power hampers their indirect integration into grids [4]. Furthermore, this volatility could increase residual loads, especially under extreme weather conditions [5]. For example, unprecedented California wildfires as a result of a heatwave reduced photovoltaic efficiency via smoke, causing 49,000 customer outages in August 2020 [6], and during the extreme winter weather of February 2021, the generation of variable renewable energy decreased by over 60% in Texas in the United States [7]. To improve supply reliability of wind–solar dominant power systems, flexible generation sources are thus introduced to provide ramping services (including upwards and downwards ramping) [8]. It is estimated that 1296–1944 GW of flexibility will be needed in 2050 to advance China’s energy transition [9], which amounts to 68.9–103.4% of the total installation capacity of hydropower (436 GW) and fossil-fired plants (1444 GW) in 2024. The difficulty of advancing renewable energy transition while guaranteeing supply reliability lies in how to meet these tremendous demands of flexibility.
Leveraging complementarity (defined as the low availability of one energy can be compensated by other energy sources [10]) between wind–solar power and other energy sources to suppress the volatility of wind–solar power, has been used to build a resilient renewable power supply system. For instance, hydro-wind, hydro-PV and hydro-wind-PV have been discussed in the literature [11,12]. Compared with separate wind or solar energy systems, the storage requirement of a complementary system reduces by approximately 50%, and the standard deviation of joint generation declines by 80% [13]. Besides leveraging additional flexible generation sources, the spatial heterogeneity of wind–solar power generation processes also enables complementarity [14]. For instance, trans-regional interconnection has been proposed to enhance supply reliability while investments decline [15,16]. It should be noted that there are notable differences between the two above forms of complementarity. The former demonstrates dispatch flexibility, and the latter focuses on heterogeneities of wind–solar power generation processes.
Shifting to wind–solar dominant systems, the flexibility of dispatchable energies is constrained by retirement of fossil-fired plants and limited hydropower [17,18]. The spatiotemporal complementarity between wind and solar power will be one of the pillars for building resilient renewable power supply systems [19]. Therefore, assessing wind–solar power complementarity and identifying hotspots with high complementarity will be highly significant for China’s renewable energy transition [20].
Various complementarity quantification indices have been proposed in the literature [13,21]. Correlation description methods are mostly used [19,22], such as the Kendall coefficient, coefficient of determination, and Person coefficient. These coefficients describe complementarity as the negative relationship between wind and solar power. However, the linear assumption of the determination coefficient and Pearson correlation coefficient limits their use in complementarity assessment [10]. Without additional assumptions, the Kendall coefficient is widely used in the literature to conduct a complement assessment [23]. The Kendall coefficient measures the difference between the number of pairs of values in two series that match in terms of direction (both differences being positive or negative) and those that have opposite signs (one difference being positive and the other negative). Therefore, the Kendall coefficient overlooks the magnitude of the increase or decrease in wind and solar power.
Other complementarity indices focus on the frequency or amplitude of extreme power events. For instance, the time-complementarity index [24], load tracking index [25], and other fluctuation-related indices [26]. It should be noted that these complementarity indices focus on quantifying systems’ performance under extreme conditions, and thus, the universal conditions characterized by high probability are ignored. The Wind and Solar Complementarity Index (CIWS) is, to the best of our knowledge, the first complementary index that integrates all output details [10]. However, the CIWS is based on Dynamic Time Warping techniques and entails stretching and compressing time [27]. Distorting the time axis results in uncertainties being introduced into the complementarity assessment, which is discussed later in this study. Consequently, a wind–solar generation complementarity index that fully integrates generation details and enables high interpretability has yet to be developed, primarily due to the tremendous volatility of wind–solar generation.
Spatially, there are more abundant wind–solar resources in the northern regions compared with the southern regions of China. Furthermore, it is projected that climate change will decrease northern wind speeds and increase radiation intensity in the south. Therefore, two questions are raised: (1) Does the geographical pattern of resource complementarity match its current distribution? (2) Will complementarity remain robust in the long term as the climate changes?
To overcome the limitations of existing complementarity indices and inspired by existing metrics, this study develops the Daily Complementarity Index of wind–solar generation (DCI) from the perspective of power profile. The reasonability of the DCI is validated through comparing existing indices and nine sites. Further, 40-year complementarity analysis is implemented to provide readers with a comprehensive understanding of China’s wind–solar power complementarity. These results are meaningful for improving our understanding of complementarity and its application during engineering practice.

2. Materials and Methods

2.1. Wind and Solar Photovoltaic Power Generation

The hourly power generation of solar photovoltaic plants (PowerPV, MW) is calculated as a function of incident radiation intensity and ambient air temperature [3].
P o w e r P V = S P P V I P V I s t γ s h a d e γ t e m ( 1 − γ l o s s )
where SPPV (MW) represents the installation capacity of solar photovoltaic plants; IPV (W m−2) is the incident radiation on PV panels; Ist (W m−2) is the captured radiation by photovoltaic panels under standard test condition (1000 W m−2); and efficiency coefficient γshade, γtem, and γloss, reflect the influences of shade by adjacent PV panels, ambient temperature, and electricity loss from solar photovoltaic plants to the electricity grid, respectively.
Hourly wind power generation is calculated as a piecewise function of wind velocity, air density, and the characteristics of wind turbines (such as hub height, rate capacity, cut-in and cut-out wind speeds) [28].
V h = ( H h H l ) α V l
P o w e r W = { 0 ,           V h ≤ V c u t   o r   V h ≥ V b r e a k 1 2 C P A ρ a i r V h 3 ,       V c u t < V h ≤ V r     P C ,               V r < V h < V b r e a k          
where Vh (m s−1) and Vl (m s−1) represent the wind velocity at hub height (Hh, m) and referring height (Hl, m), respectively. Parameter α is the Hellman coefficient, which is estimated from 10 m and 100 m wind velocity provided by the Global Wind Atlas v3 dataset with a spatial resolution of 250 m × 250 m [29]; Vcut (m s−1) is the cut-in wind speed; Vbreak (m s−1) is the cut-out wind speed; Vr (m s−1) is the rate wind speed; CP is the turbine efficiency; A (m2) is the sweat area of the rotor; and ρair (kg m−3) is air density.

2.2. Daily Complementarity Index of Wind–Solar Power

DCI quantifies complementarity through measuring areas of specific region regarding wind–solar generation curves, with reference to the CIWS. However, there are notable differences in the definition and calculation methods used by the DCI and CIWS.
The CIWS measures complementarity with the similarity of wind and solar generation curves, which is calculated as the area enclosed by both shifted wind and solar generation curves (Equation (4)). The aim of shifting wind and solar generation curves is to amplify differences in generation curves, and this is conducted through applying Dynamic Time Warping techniques. Specifically, shifted wind and solar generation curves are characterized by minimal dissimilarity, quantified as MAE [27].
C I W S = ∫ t T | ( P o w e r P V − P o w e r W ) | d t
M A E = ∑ n N | P o w e r P V , n ¯ − P o w e r W , n ¯ | N
where | P o w e r P V , n ¯ − P o w e r W , n ¯ | represents the Euclidean distance between vector pairs of wind–solar generation PowerPV,n and PowerW,n. According to the definition of the CIWS, a higher CIWS means that there is less similarity between wind and solar generation curves. In particular, there is no complementarity when the CIWS equals zero. Under this condition, shifted wind and solar generation curves coincide with each other. In other words, the CIWS defines the similarity of wind and solar power generation curves, which lacks explicit physical meaning.
In contrast, the DCI describes the stability of joint wind–solar generation. Generally, PV power is characterized by a sharp increase and then decrease throughout the daytime, and there is no generation during the night. In contrast, wind power is more persistent throughout the whole day and potentially compensates for PV power [30,31]. Therefore, wind power is set as the complementary power source in the DCI to compensate for the low availability of solar power.
Based on the definition of complementarity, ideal complementarity results in a stable joint generation of a wind–solar system [32]. Consequently, for a given solar power curve (Figure 1a), it is assumed that the joint generation of wind–solar power should be equal to 1, indicating that there are no fluctuations. To satisfy this assumption, the expected generation curve (PV0) can be described using Equation (1) and the dashed line in Figure 1b. Compared with PV0, wind power is divided into two components: (1) effective complementary power (ECP; Figure 1c), which compensates for solar energy generation, and (2) curtailment (Curtail; Figure 1d), which represents a part of wind power that exceeds PV0. The curtailment is explained as follows: exceeding wind power adding solar power exceeds 1, and this thus introduces additional fluctuations. On the other hand, if PV0 is calculated as the difference between solar power generation and load demand, the exceeding wind power reflects power higher than the load demand, i.e., curtailment. Consequently, the exceeding wind power is named curtailment. ECP and Curtail are calculated in Equations (2) and (3), respectively.
Figure 1. Schematic diagram of Daily Complementarity Index of wind–solar power. (a) Daily power generation curve of solar photovoltaic plants (blue lines); (b) Illustration of expected complementary generation curve (dashed lines), which is defined by Equations (6) and (7); According to differences between wind power generation (red lines) and expected complementary cures, wind power generation is divided as two components: effective complementary power (c) and curtailment (d); (green area).
Furthermore, it can be deduced that the sum of ECP and Curtail is equal to the total generation of wind plants (i.e., Equation (9)). Accordingly, complementarity can be expressed as in Equation (10). However, it should be noted that Equation (10) is not symmetric as DCI(x, y) ≠ DCI(y, x) in general. Accordingly, solar power generation is introduced into Equation (11) to make symmetry between the variables.
P V 0 = 1 − P o w e r P V
E C P = ∫ t T m i n ( P V 0 , P o w e r W ) d t
C u r t a i l = ∫ t T max ( 0 ,   P o w e r W − P V 0 ) d t
E C P = ∫ t T P o w e r W d t − C u r t a i l
D C I * = E C P − C u r t a i l
D C I = ( ∫ t T P o w e r W d t − 2 × C u r t a i l + ∫ t T P o w e r P V d t ) / ∫ t T 1 d t
where PowerPV is the generation of solar plants, PowerW is the generation of wind plants, and dt is the time step. Here, as there are significant differences in resource endowment, land availability, and electricity demand among various regions, the actual installation capacity of wind and solar plants is uncertain [11,26]. To eliminate the influences of the above uncertainties, the generation of wind and solar plants is standardized (Equation (12)). Meanwhile, ∫ t T 1 d t is used to standardize the DCI to the range of −1 to 1. This range is proven by Equations (8)–(11).
P o w e r i = P o w e r / C a p a c i t y
∫ t T P o w e r W d t − C u r t a i l ≥ 0
C u r t a i l ≤ ∫ t T 1 d t
∫ t T P o w e r P V d t − C u r t a i l ≥ ∫ t T P o w e r P V d t − ∫ t T 1 d t ≥ − ∫ t T 1 d t
0 ≤ ∫ t T P o w e r P V d t ≤ ∫ t T 1 d t
where Poweri (MW) is the generation of wind or solar plants under the given installed capacity; Power (MW) is the hourly generation of wind or solar plants at each raster. Capacity (MW) is the installation capacity of wind or solar plants at each raster.

2.3. Characteristics of the DCI

For fully complementary wind–solar power, the wind generation curve is the same as the expected complementary curve (i.e., ECP = PV0 and Curtail = 0). As defined in Equations (6)–(11), the DCI is thus equal to 1 and represents the highest complementarity. When the DCI is negative, there is no complementarity. A negative DCI physically represents that curtailment counteracts complementarity from ECP. Graphically, wind power and PV power curves exhibit similarity under this condition. The worst condition is that the generation of wind and solar plants is equal to capacity, and thus, Curtail is equal to wind and solar generation. Under this condition, the DCI is equal to −1.
On the other hand, regions with more abundant solar resources exhibit lower PV0 values, as indicated by Equation (6), consequently reducing the output requirements for wind power. Similarly, regions with more abundant wind resources demonstrate higher ECP according to Equation (7), indicating greater complementary potential. Thus, areas with a higher DCI generally align spatiotemporally with regions possessing superior wind and solar resource endowments.

2.4. Study Area and Data

The complementarity analysis was conducted across mainland China (4° N–53.5° N, 73.5° E–97° E). Furthermore, the provincial analysis was implemented with the aim of guiding trans-regional interconnection for building a resilient renewable energy system in China. Furthermore, to validate the effectiveness of the DCI, the complementarity of nine sites covering typical regions with abundant or scarce wind–solar resources (Figure 2) is analyzed.
Figure 2. Study area and nine selected sites.

2.5. Existing Indices and Statistical Analysis

The coefficient of variance (COV) and standard deviation (std) are adopted to analyze the temporal variability of the DCI under various meteorological conditions. Both of these indices are calculated as follows:
s t d = ( x i − x ¯ ) 2 / ( n − 1 )
C O V = s t d / [ ( ∑ i = 0 n x i ) / n ]
where xi represents the value of the DCI in ith year; x ¯ is the mean DCI of the study period (from 1984 to 2023); and n is the number of samples included in the study period.

3. Results

3.1. Improvement in the DCI Compared with Other Indices

The different performances of the three indices, including the Kendall Tau index, CIWS, and DCI, are shown in Figure 3. By comparing the scenario of Figure 3a with that of Figure 3b, wind power compensates for the solar power deficit during the night, and generation curves change in the same direction. However, the declined daily wind generation of the scenario in Figure 3b and the increased solar power benefits decrease curtailment and improve wind–solar complementarity. Consequently, the complementarity in Figure 3b should be higher than that in Figure 3a. This enhancement is captured by the CIWS and DCI but not by the Kendall Tau index because that index only focuses on the synchronicity of a change in direction.
Figure 3. Comparison between the DCI and Kendall Tao index and the CIWS. (a) Examples of wind and solar power generation curves; (b) Compared with (a), there is a decrease of wind power at noon while wind power changes in the same direction; (c) there are the same shape of wind and solar power generation but with time hysteresis. Red and green areas represent effective complementary power and curtailment, respectively.
As the CIWS involves the process of linearly compressing and expanding the temporal axis, when wind and solar power curves are characterized by the same profile but with time hysteresis, the CIWS is equal to 0 (Figure 3c). However, wind power compensates for the solar power deficit after 15:00, which implies that the CIWS fails to capture these characteristics under this condition. In contrast, the DCI is 0.32, showing that the DCI captures this complementarity.
The above results indicate that there are some limitations in complementarity assessment when using the Kendall Tau index and CIWS, while these limitations are not observed in the results where the DCI was used. Accordingly, the DCI’s performance surpasses that of the two other indices mentioned.

3.2. Reasonability Analysis of DCI

The daily standardized generation curves extracted from nine sites (Table 1) and the corresponding values of the DCI are shown in Figure 4. As defined by Equations (6)–(11), a higher value of the DCI will be expected from conditions that are characterized by high wind generation at night and solar generation in the day. This analysis is confirmed by the results of sites 1 and 7 (Figure 4a,g), where the values of the DCI are 33.34% and 42.17% higher than the average value of the nine sites, respectively. However, the wind power of site 1 during the day approaches rated power, implying that there are increased curtailment risks when wind–solar power is in joint operation. Therefore, the DCI of site 1 declines by 0.09 compared with that of site 7. A similar possible negative complementarity of high wind generation is also observed in sites 2 and 3 (Figure 4b,c). For instance, the solar power curves of the two sites are similar, but the curtailment in site 2 is higher than that of site 3 due to higher wind generation during the day. As a result, the DCI of site 2 is 5.88% lower than that of site 3.
Table 1. Geographical information and daily wind–solar complementarity of nine sites.
Figure 4. Value of the DCI in nine selected sites. (a–i) represent daily wind and solar power generation of nine sites, which shown in Figure 2.
On the other hand, it has been mentioned that the similarity of wind power and PV power curves can jeopardize complementarity. This jeopardization is shown by the 0.04 decrease in the DCI in site 3 compared with site 6, in which these two sites show similar generation curves (Figure 4c,f). Furthermore, the DCI results of the other sites fully follow the theoretical projections made by Equations (6)–(11) and the complementarity depicted in wind–solar curves. Accordingly, the results of the nine sites prove the reasonability of the DCI.

3.3. Spatial Pattern of Complementarity

The average DCI of China is 0.26 ± 0.13, where the maximum and minimum are 0.88 and 0.06, respectively. Spatially, there is an evident spatial pattern of being lower in the south and higher in the north (Figure 5a). A pronounced low-DCI zone is present across the Sichuan Basin and Chongqing municipality; meanwhile, a high-DCI zone is observed along the Three-North Shelterbelt, which is characterized as an abundant wind energy resource.
Figure 5. Spatial pattern of complementarity of wind–solar power in China. (a) Map of complementarity of each raster (with a spatial resolution of 0.1° × 0.1°); (b) map of provincial average complementarity.
Provincially, the average DCI is 0.23 ± 0.08 (Figure 5b). Generally, provinces with better wind–solar endowment are characterized by higher complementarity, such as the five northern provinces (including Gansu, Qinghai, Ningxia, Shaanxi, and Xinjiang). The highest DCI (i.e., 0.39) and the lowest DCI (i.e., 0.09) are observed in Inner Mongolia and Taiwan, respectively.

3.4. Temporal Variability of Complementarity

Annually, the complementarity of wind–solar power tends to follow a slight increase trend (3.96 × 10−5 year−1) across China from 1984 to 2023 (Figure 6a). The maximum (i.e., 0.27) and the minimum (i.e., 0.25) were observed in 2009 and 1992, respectively, and the COV of the DCI was 0.02. These inter-annual results imply low variations in the DCI in China, which is beneficial for a national transition to a wind–solar-dominated renewable power system.
Figure 6. Annual (a) and monthly (b) variations in wind–solar power complementarity. Red dashed line in panel (a) represents annual mean value of DCI. Blue line in panel (b) is monthly mean value of DCI. Gray lines in panel (b) represent monthly variations over forty years.
Meanwhile, there is an evident seasonal characteristic of complementarity, in which the highest and lowest are 0.37 and 0.17, respectively (Figure 6b). Winter (covering November, December, January, and February) is characterized by the lowest DCI (average DCI is 0.22, which is 15.38% lower than the annual average), and the highest DCI is observed in the spring (covering March, April, and May, when the average DCI is 0.30, which is 16.46% lower than the annual average). Monthly, wind–solar power complementarity follows a trend that DCI increases from January to May and then decreases (Figure 6b).
Provincially, most regions exhibit increased complementarity from 1984 to 2023 (Figure 7a). However, the complementarity of six regions is characterized by a declined trend, including Xizang (−3.29 × 10−5 year−1), Qinghai (−1.15 × 10−5 year−1), Hainan (−2.40 × 10−5 year−1), Guangdong (−6.93 × 10−5 year−1), Jiangsu (−3.72 × 10−5 year−1), and Shanghai (−2.99 × 10−4 year−1). Provincial monthly variations in the DCI also follow the same trend as the national analysis results (Figure 7b).
Figure 7. Temporal changes in the complementarity of wind–solar power at the provincial level. (a) Long-term changes in the trend of complementarity; (b) monthly provincial average value of the DCI.

4. Discussion

4.1. Value of the DCI in Complementarity Assessment

Multiple complementarity quantification indices have been proposed and implemented in scientific research [19]. However, there is a possibility that existing indices cannot correctly present wind and solar power complementarity [10], as shown by the results outlined in Figure 3. The DCI is thus developed in this study, and its reasonability has also been proven.
One advantage of the DCI is its explicit physical meaning and high interpretability. As shown in Figure 4, the higher value of the DCI is generally explained by contrary generation processes. For instance, there is increased wind generation at night but decreased solar generation as solar photovoltaic plants generate electricity during the day. Furthermore, resource endowment is another factor that can explain this complementarity. For example, the difference in the DCI between Figure 4b,f is attributed to weaker wind resource endowment in the southeastern region because the similar shape of generation curves excludes the impacts of generation processes.
Although the DCI is defined as a daily scale for wind–solar power complementarity quantification (Equations (6)–(11)), other energy sources (e.g., hydropower) or combinations (e.g., wind–wind and solar–solar) can easily be integrated into the DCI. This integration is significant for advancing the renewable energy transition. For instance, southwestern regions are characterized by low wind–solar power complementarity, while hydropower is abundant in these regions [4] (Figure 4a). Hydropower could be integrated into the DCI, with the aim of integrating regional wind and solar energy [33]. Meanwhile, trans-regional complementarity analysis can also be achieved. In summary, capitalizing on the strengths of the DCI, integrating it into complementarity assessment allows for a deeper understanding of wind–solar resource characteristics to be gained and provides guidance for planning hybrid power plants.

4.2. Integrating Wind–Solar Complementarity into Optimization Framework

To relieve tremendous calculation burdens, scenario clustering at both spatial and temporal scales is widely adopted by existing optimization frameworks for hydro–wind–solar renewable energy bases [34]. However, clustering masks the heterogeneities of wind–solar power generation, even if these plants are located at different locations and impacted by various weather conditions [35]. Consequently, integrated wind–solar capacity is highly dependent on the dispatching capability of hydropower plants [36]. Nevertheless, prior studies have demonstrated notable spatiotemporal differences in wind–solar resources, which implies potential complementarity [37]. Leveraging these differences, a cross-regional interconnection mode is thus proposed to build resilient renewable power systems. For instance, interconnection between Asia and Oceania improves their reliability by 1.7% and 4.7%, respectively [16]. However, complementarity is not integrated into the optimization framework.
Here, we suggest integrating wind–solar complementarity into the optimization framework. The feasibility of this integration emerges from the results revealed in this study. Temporally, although climate change has been amplifying the variability, intermittency, and randomness of wind and solar power [38,39], historically (from 1984 to 2023), there have not been any significant changes in the complementarity of wind–solar power in China (Figure 6). This temporal stability guarantees the reliability of wind–solar power generation. The power generation of wind–solar plants that experience different changing trends can compensate for each other. For instance, strategically, situating wind and solar photovoltaic plants in northern regions should be the priority given their remarkable advantages in complementarity and resource endowment (Figure 5).
However, the monthly results reveal that the highest wind–solar power complementarity reaches only 0.37 (Figure 6b), which will result in a tremendous challenge when it comes to achieving a supply–demand balance. In particular, summer and winter are commonly characterized by low complementarity, but escalating electricity demands are being faced due to cooling and heating demands [40,41]. Accordingly, these quantitative results demonstrate that flexible generation sources (such as hydropower, fossil-based plants) and storage are also essential for building resilient renewable power systems [42].

4.3. Implications for Future Research

This spatiotemporal heterogeneity enables complementarity [43]. Two research directions are raised that need to be considered in future studies: (1) the effect of geographical distance on cross-regional complementarity, and (2) the influence of complementarity-aware planning on overall investments [44].
Larger geographical ranges generally coincide with more complicated weather conditions, implying higher potential complementarity. Having an explicit understanding of the relationship between complementarity and geographical ranges is meaningful for determining the reasonable boundary of the hydro–wind–solar renewable energy base.
With the aim of pursuing higher complementarity, the locations of wind–solar plants could be different from those optimized with the highest cost-effectiveness. Consequently, increased investment cannot be avoided. Nevertheless, considering that increased electricity generation in long-term operation benefits from complementarity and decreased volatility, additional investment could be recovered.

5. Conclusions

In this study, a physics-based complementarity index of wind–solar power is developed, and a quantified analysis of China spanning 40 years is conducted. The results of the comparison with existing complementarity indices and validation using nine sites confirm the reasonability of the DCI and its improvements in interpretability. Spatially, the average DCI of China is 0.26 ± 0.13, with a pronounced low-DCI zone across the Sichuan Basin and Chongqing municipality and a high-DCI zone along the Three-North Shelterbelt. Mechanistically, the higher value of the DCI is generally explained by contrary generation processes, and resource endowment is another factor that can explain the variations in the DCI. Temporally, the complementarity of wind–solar power in China follows a slight increase trend; however, there are regional heterogeneities. These findings can strengthen our confidence in facilitating a wind–solar-dominated renewable power transition; strategically establishing wind and solar photovoltaic plants in northern regions should be the priority. Given the potential of wind–solar generation complementarity to improve supply reliability and the declining demands for flexibility, further research is required to integrate wind–solar complementarity into the optimization framework, and the economic influences of this integration also need to be considered.

Author Contributions

Conceptualization, C.W., L.T. and Y.L.; methodology, C.W. and Y.L.; validation, C.W.; formal analysis, C.W.; data curation, C.W.; writing—original draft preparation, C.W.; writing—review and editing, C.W., L.T., C.D., Y.X. and H.Z.; visualization, C.W.; supervision, L.T.; funding acquisition, L.T. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by projects of the China Hudian Corporation Ltd. (grant number CHDKJ23-02-02-03), and the State Key Laboratory of Hydroscience and Engineering, grant number sklhse-TD-2024-A01.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

10 m wind speed, 2 m temperature and surface radiation are compiled from ERA5-Land dataset [45]. 10 m and 100 m wind speed from the Global Wind Atlas [29].

Acknowledgments

This study is supported by projects of the China Hudian Corporation Ltd. and the State Key Laboratory of Hydroscience and Engineering.

Conflicts of Interest

Lihua Tang has received research grants from the company Huadian Xizang Energy Co. Authors Deng Changyong, Xie Youyi and Zheng Hongwei, are employed by the company Huadian Xi-zang Energy Co., Ltd. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships.

Abbreviations

The following abbreviations are used in this manuscript:
DCIDaily Complementarity Index of wind–solar power
ECPEffective complementary power
CurtailCurtailment
COVCoefficient of variance

References

  1. He, C.; Jiang, K.; Xiang, P.; Jiao, Y.; Li, M. Electricity Demand Characteristics in the Energy Transition Pathway Under the Carbon Neutrality Goal for China. Sustainability 2025, 17, 1759. [Google Scholar] [CrossRef] [Scilit]
  2. Shu, Z.; Chen, W.-Y. China’s Energy Transition Pathway in a Carbon Neutral Vision. Engineering 2022, 14, 64–76. [Google Scholar] [CrossRef] [Scilit]
  3. Wang, Y.; Wang, R.; Tanaka, K.; Ciais, P.; Penuelas, J.; Balkanski, Y.; Sardans, J.; Hauglustaine, D.; Liu, W.; Xing, X.; et al. Accelerating the energy transition towards photovoltaic and wind in China. Nature 2023, 619, 761–767. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Shen, J.; Wang, Y.; Lin, M.; Cheng, C.; Kazak, J.K.; Wang, J.; Guo, X.; Li, X.; Zhou, B.; Ge, L. Quantifying the impact of extreme weather on China’s hydropower–wind–solar renewable energy system. Nat. Water 2025, 3, 415–429. [Google Scholar] [CrossRef] [Scilit]
  5. Van der Most, L.; van der Wiel, K.; Benders, R.-M.-J.; Gerbens-Leenes, P.-W.; Bintanja, R. Temporally compounding energy droughts in European electricity systems with hydropower. Nat. Energy 2024, 9, 1474–1484. [Google Scholar] [CrossRef] [Scilit]
  6. California Independent System Operator. Preliminary Root Cause Analysis Mid-August 2020 Heat Storm. Available online: https://www.caiso.com/documents/preliminary-root-cause-analysis-rotating-outages-august-2020.pdf (accessed on 6 October 2020).
  7. Zhao, J.; Li, F.; Zhang, Q. Impacts of renewable energy resources on the weather vulnerability of power systems. Nat. Energy 2024, 9, 1407–1414. [Google Scholar] [CrossRef] [Scilit]
  8. Jiang, K.; Liu, N.; Wang, K.; Chen, Y.; Wang, J.; Liu, Y. Spatiotemporal assessment of renewable adequacy during diverse extreme weather events in China. Nat. Commun. 2025, 16, 5198. [Google Scholar] [CrossRef] [Scilit]
  9. Ya, Z.; Yang, S. How Much Flexibility Resources Are Needed for the Renewable Energy System? South Energy Watch 2024. Available online: https://mp.weixin.qq.com/s/XZTVmZDwB83VHWbXWPsQcA (accessed on 16 July 2024). (In Chinese)
  10. Frías-Paredes, L.; Gastón-Romeo, M. A new methodology to easy integrate complementarity criteria in the resource assessment process for hybrid power plants: Offshore wind and floating PV. Energy Convers. Manag. X 2025, 26, 100938. [Google Scholar] [CrossRef] [Scilit]
  11. Jing, -J.; Wang, Y.-M.; Chang, J.-X.; Wang, X.-B.; Guo, A.-J.; Meng, X. Construction of pumped storage power stations among cascade reservoirs to support the high quality power supply of the hydro-wind-photovoltaic power generation system. Energy Convers. Manag. 2025, 323, 119239. [Google Scholar] [CrossRef] [Scilit]
  12. Wang, F.-J.; Xu, J.-P.; Wang, Q. Complementary operation based sizing and scheduling strategy for hybrid hydro-PV-wind generation systems connected to long-distance transmission lines. Appl. Energy 2024, 364, 123082. [Google Scholar] [CrossRef] [Scilit]
  13. Heide, D.; Von Bremen, L.; Greiner, M.; Hoffmann, C.; Speckmann, M.; Bofinger, S. Seasonal optimal mix of wind and solar power in a future, highly renewable Europe. Renew. Energy 2010, 35, 2483–2489. [Google Scholar] [CrossRef] [Scilit]
  14. Li, M.; Ma, Q.; Shan, R.; Abdulla, A.; Virguez, E.; Gao, S.; Patiño-Echeverri, D. Renewable energy quality trilemma and coincident wind and solar droughts. Commun. Earth Environ. 2024, 5, 661. [Google Scholar] [CrossRef] [Scilit]
  15. Hou, J.; Ling, Y.; Jun, Q.; Bai, Y.-Q.; Martin, B.; Xu, L.; Steve, J.-D.; Ning, L.; Zhao, W.-L.; Liu, T.; et al. Globally interconnected solar-wind system addresses future electricity demands. Nat. Commun. 2025, 16, 4523. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Zheng, D.; Yan, X.; Tong, D.; Davis, S.J.; Caldeira, K.; Lin, Y.; Guo, Y.; Li, J.; Wang, P.; Ping, L.; et al. Strategies for climate-resilient global wind and solar power systems. Nature 2025, 643, 1263–1270. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  17. An, K.; Zheng, X.; Shen, J.; Xie, C.; Wang, C.; Cai, W.; Bu, C. Repositioning coal power to accelerate net-zero transition of China’s power system. Nat. Commun. 2025, 16, 2311. [Google Scholar] [CrossRef] [Scilit]
  18. Wang, R.; Cai, W.; Cui, R.-Y.; Huang, L.; Ma, W.; Qi, B.; Zhang, J.; Bian, J.; Li, H.; Zhang, S.; et al. Reducing transition costs towards carbon neutrality of China’s coal power plants. Nat. Commun. 2025, 16, 241. [Google Scholar] [CrossRef] [Scilit]
  19. Tong, D.; Farnham, D.-J.; Duan, L.; Zhang, Q.; Lewis, N.-S.; Caldeira, K.; Davis, S.-J. Geophysical constraints on the reliability of solar and wind power worldwide. Nat. Commun. 2021, 12, 6146. [Google Scholar] [CrossRef] [Scilit]
  20. Zhou, X.; Chen, H.; Ding, G. Advancing Sustainable Development and the Net-Zero Emissions Transition: The Role of Green Technology Innovation, Renewable Energy, and Environmental Taxation. Sustainability 2026, 18, 221. [Google Scholar] [CrossRef] [Scilit]
  21. Takle, E.S.; Shaw, R.-H. Complimentary nature of wind and solar energy at a continental mid-latitude station. Int. J. Energy Res. 1979, 3, 103–112. [Google Scholar] [CrossRef] [Scilit]
  22. Mario, M.-M.; Thomas, H.; Monforti-Ferrario, F. Local Complementarity of Wind and Solar Energy Resources over Europe: An Assessment Study from a Meteorological Perspective. JAMC 2017, 56, 217–234. [Google Scholar]
  23. Han, S.; Zhang, L.-N.; Liu, Y.-Q.; Zhang, H.; Yan, J.; Li, L.; Lei, X.-H.; Wang, X. Quantitative evaluation method for the complementarity of wind–solar–hydro power and optimization of wind–solar ratio. Appl. Energy 2019, 236, 973–984. [Google Scholar] [CrossRef] [Scilit]
  24. Alexandre, B.; Paulo, K.-S.; Krenzinger, A. A dimensionless index evaluating the time complementarity between solar and hydraulic energies. Renew. Energy 2008, 33, 2157–2165. [Google Scholar] [CrossRef] [Scilit]
  25. Zhu, J.-Z.; Xiong, X.-F.; Xuan, P. Dynamic economic dispatching strategy based on multi-time-scale complementarity of various heterogeneous energy. DEStech Trans. Environ. Energy Earth Sci. 2018, 822–837. [Google Scholar] [CrossRef] [Scilit]
  26. Akinobu, M.; Hiroshi, Y.; Otani, K. A method of estimating the output fluctuation of many photovoltaic power generation systems dispersed in a wide area. EEJ 2008, 166, 9–19. [Google Scholar]
  27. Sakoe, H.; Chiba, S. Dynamic programming algorithm optimization for spoken word recognition. IEEE Trans Acoust 1978, 26, 43–49. [Google Scholar] [CrossRef] [Scilit]
  28. Li, M.; Virguez, E.; Shan, R.; Tian, J.; Gao, S.; Patiño-Echeverri, D. High-resolution data shows China’s wind and solar energy resources are enough to support a 2050 decarbonized electricity system. Appl. Energy 2022, 306, 117996. [Google Scholar] [CrossRef] [Scilit]
  29. Davis, N.; Badger, J.; Hahmann, A.-N.; Hansen, B.-O.; Olsen, B.-T.; Mortensen, N.-G.; Heathfield, D.; Onninen, M.; Lizcano, G.; Lacave, O. Global Wind Atlas v3. 2024. Available online: https://data.dtu.dk/articles/dataset/Global_Wind_Atlas_v3/9420803 (accessed on 26 November 2025).
  30. Fan, J.-L.; Huang, X.; Shi, J.; Li, K.; Cai, J.; Zhang, X. Complementary potential of wind-solar-hydro power in Chinese provinces: Based on a high temporal resolution multi-objective optimization model. Renew. Sustain. Energy Rev. 2023, 184, 113566. [Google Scholar] [CrossRef] [Scilit]
  31. Cui, Q.; He, L.; Han, G.; Chen, H.; Cao, J. Review on climate and water resource implications of reducing renewable power curtailment in China: A nexus perspective. Appl. Energy 2020, 267, 115114. [Google Scholar] [CrossRef] [Scilit]
  32. Jurasz, J.; Canales, F.-A.; Kies, A.; Guezgouz, M.; Beluco, A. A review on the complementarity of renewable energy sources: Concept, metrics, application and future research directions. Sol. Energy 2020, 195, 703–724. [Google Scholar] [CrossRef] [Scilit]
  33. Liu, Z.; He, X. Balancing-oriented hydropower operation makes the clean energy transition more affordable and simultaneously boosts water security. Nat. Water 2023, 1, 778–789. [Google Scholar] [CrossRef] [Scilit]
  34. Zhang, H.; Lu, Z.; Hu, W.; Wang, Y.; Dong, L.; Zhang, J. Coordinated optimal operation of hydro–wind–solar integrated systems. Appl. Energy 2019, 242, 883–896. [Google Scholar] [CrossRef] [Scilit]
  35. Fan, Y.-K.; Zhong, P.-A.; Zhu, F.-L.; Ran, M.; Wang, H.; Wei, J.; Zeng, Y.-R.; Wang, B.; Qian, X. Assessing the potential and complementary characteristics of China’s solar and wind energy under climate change. Renew. Energy 2025, 249, 123213. [Google Scholar] [CrossRef] [Scilit]
  36. Wu, C.; Liu, P.; Cheng, Q.; Yang, Z.; Huang, K.; Liu, Z.; Zheng, Y.; Li, X.; Zhou, Y.; Jiang, D.; et al. Analytical method for optimizing capacity expansion of existing hydropower plants in hydro-wind-photovoltaic hybrid system: A case study in the Yalong River basin. Appl. Energy 2025, 383, 125297. [Google Scholar] [CrossRef] [Scilit]
  37. Wang, L.; Liu, Y.; Zhao, L.; Lu, X.; Huang, L.; Jin, Y.; Davis, S.-J.; Aghakouchak, A.; Huang, X.; Zhu, T.; et al. Unraveling climate change-induced compound low-solar-low-wind extremes in China. Natl. Sci. Rev. 2025, 12, nwae424. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  38. Zhu, X.-R.; Tian, J.-H.; Wang, Y. The impact of climate change on wind and solar photovoltaic power potential and distribution in China. Adv. Clim. Change Res. 2025, 16, 730–746. [Google Scholar] [CrossRef] [Scilit]
  39. Perera, A.-T.-D.; Nik, V.-M.; Chen, D.; Scartezzini, J.-L.; Hong, T. Quantifying the impacts of climate change and extreme climate events on energy systems. Nat. Energy 2020, 5, 150–159. [Google Scholar] [CrossRef] [Scilit]
  40. Staffell, I.; Pfenninger, S.; Johnson, N. A global model of hourly space heating and cooling demand at multiple spatial scales. Nat. Energy 2023, 8, 1328–1344. [Google Scholar] [CrossRef] [Scilit]
  41. Huang, Z.-F.; Chen, W.-D.; Wan, Y.-D.; Shao, Y.-L.; Islam, M.-R.; Chua, K.-J. Techno-economic comparison of different energy storage configurations for renewable energy combined cooling heating and power system. Appl. Energy 2024, 356, 122340. [Google Scholar] [CrossRef] [Scilit]
  42. Ling, X.; Wang, Y.; Li, X.; Li, B.; Tang, F.; Ding, J.; Yu, Y.; Jiang, X.; Zhou, T. Multi-Scenario Investment Optimization in Pumped Storage Hydropower Using Enhanced Benders Decomposition and Isolation Forest. Sustainability 2025, 17, 10657. [Google Scholar] [CrossRef] [Scilit]
  43. Taušová, M.; Mykhei, M.; Čulková, K.; Tauš, P. Comparison of Renewable Energy Implementation in Geographically and Climatically Diverse Regions. Sustainability 2025, 17, 3098. [Google Scholar] [CrossRef] [Scilit]
  44. Orozco, I.H.; Banacloche, S.; Lechón, Y.; Dominguez, J. Assessing the Socioeconomic and Environmental Impact of Hybrid Renewable Energy Systems for Sustainable Power in Remote Cuba. Sustainability 2025, 17, 7592. [Google Scholar] [CrossRef] [Scilit]
  45. Muñoz, S.-J. ERA5-Land Hourly Data from 1950 to Present. 2019. Available online: https://cds.climate.copernicus.eu/datasets/reanalysis-era5-land?tab=overview (accessed on 12 July 2019).
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.