Skip to Content
  • Article
  • Open Access

22 April 2026

14 Pages

Frequency Scanning-Based Simplified Overvoltage Prediction Method for SiC Inverter-Fed Motor Drives in Electric Vehicles

,
,
,
and
1
School of Mechanical and Electrical Engineering, Yibin University, Yibin 644000, China
2
National Key Laboratory of Explosion Science and Safety Engineering, Beijing Institute of Technology, Beijing 100081, China
*
Author to whom correspondence should be addressed.

Abstract

Wide-bandgap power devices, particularly silicon carbide (SiC) MOSFETs, have seen widespread adoption in electric vehicle (EV) motor drive systems due to their superior switching characteristics, including high switching speeds and high switching frequencies. However, these advantages exacerbate motor terminal overvoltage, with peaks reaching twice the inverter output voltage, causing insulation breakdown in windings and bearing electro-corrosion, which shorten motor lifespan. Traditional overvoltage prediction methods, such as distributed parameter models or detailed ladder network approaches, require extensive system parameters and involve high computational loads, while simplified models lack generality. To address these issues, this paper proposes a simplified prediction method based on a lumped ladder network model combined with frequency scanning. The approach uses impedance analysis to identify anti-resonance frequencies, enabling direct estimation of overvoltage amplitudes without prior knowledge of cable or motor specifics. Experimental validation on a SiC-based drive system demonstrates prediction errors below 10% and a reduction in computational time compared to conventional methods.

1. Introduction

The rapid development of electric vehicles (EVs) has driven the adoption of wide-bandgap power devices [1], such as silicon carbide MOSFETs, in motor drive systems due to their high switching speeds and high switching frequencies, which significantly enhance power density and efficiency. However, these advantages give rise to severe overvoltage at the motor terminals, while inevitably increasing losses and raising the operating temperature of the motor [2,3,4], thereby threatening its reliability and service life [5,6]. The overvoltage detection of EVs’ motor drive systems is influenced by three aspects: the hazards of overvoltage caused by wide-bandgap converters [7], the limitations of existing detection methods [8], and the complexity of prediction models [9].
First, the high switching characteristics of wide-bandgap converters lead to rapid voltage change rates (dv/dt) in PWM pulses [10]. When these pulses propagate through cables to the motor terminals, impedance mismatch between the cable and motor causes wave reflection phenomena, resulting in overvoltage. Peak overvoltage can reach twice the inverter output voltage (e.g., exceeding 100 V in a 50 V DC-link system), subjecting motor windings to additional electrical stress, as shown in Figure 1. This can induce inter-turn or phase-to-phase insulation breakdown and exacerbate bearing electro-corrosion, shortening motor life.
Figure 1. The overvoltage of the motor terminal.
Second, existing overvoltage detection methods primarily rely on energized testing, which involves real-time monitoring during motor operation. While this approach captures transient overvoltage, it requires the motor to be powered during testing, increasing costs and risks. Energized detection can trigger irreversible insulation failures, such as inter-turn short circuits, during the testing phase, particularly in high-frequency SiC-based drives. Moreover, this method cannot predict overvoltage at the design stage, lacking preventive capabilities and hindering its application in the iterative design processes of EVs.
Third, current overvoltage prediction models often depend on distributed parameter models or detailed ladder network approaches. These models require precise extraction of parasitic parameters (e.g., per-unit length inductance and capacitance) and account for frequency response characteristics. Although distributed models improve prediction accuracy, parameter extraction is complex, computationally intensive, and sensitive to input frequencies and motor types, thus limiting their generality. Simplified fitting models reduce computational load but are constrained to specific frequency responses, struggling to adapt to variable cable lengths and load conditions in EVs.
In summary, wide-bandgap converter-driven motor systems face significant overvoltage hazards, while existing detection and prediction methods exhibit limitations in practicality and generality. Therefore, developing a simplified overvoltage prediction method for early risk assessment during the electric vehicle design phase, thereby enhancing the operational reliability of the system, has great practical significance.
Previously, a wealth of research [11,12,13,14,15,16] has extensively explored the mechanisms underlying overvoltage phenomena, with a primary focus on wave reflection theory. Notably, prior research such as that presented in ref. [11] has systematically analyzed the voltage pulse reflection process in long cables, identifying impedance mismatch between the cable and motor terminals as the fundamental cause of voltage doubling at the motor end. This work established that PWM pulses propagating along cables generate reflected waves, which superpose to create overvoltage. This reflection phenomenon is illustrated in Figure 2, which shows how repeated reflections can lead to voltage amplification. However, in practical inverter–cable–motor systems, the reflection coefficient—conventionally determined by the characteristic impedances of the cable and motor—does not fully account for high-frequency effects, leading to inaccuracies in predicting motor terminal overvoltage. Further studies, such as those by ref. [17], revealed that high-frequency harmonics at switching frequencies exacerbate oscillations, linking overvoltage peaks to resonant frequencies.
Figure 2. The reflection phenomenon.
Subsequent research has focused on experimental validation and simplified modeling approaches to address overvoltage issues [18]. For instance, experimental work in ref. [19] confirmed the wave reflection mechanism using cables of different lengths and illustrated its detrimental impact on motor insulation. However, when developing equivalent models for cables of varying lengths, the unit length parameters are often difficult to determine precisely, making it challenging to establish length-dependent equivalent models that accurately represent cables in actual systems. Studies such as ref. [20] developed lumped-parameter fitting models that lower computational burden via frequency response scanning. However, their applicability is often restricted to specific cable types, lacking broader adaptability. Research has also emphasized the impact of high switching speeds; as noted in ref. [21], significant discrepancies arise in traditional models at frequencies exceeding 100 kHz, highlighting the challenges introduced by wide-bandgap devices. Furthermore, the significant impact of mismatched reflection coefficient and impedance on the accuracy of motor overvoltage prediction was studied in ref. [22]. High-frequency model fitting can improve the accuracy of terminal overvoltage prediction to a certain extent. However, research has found that the characteristic impedance of cables and motors (which is influenced by a series of factors such as the position and shape of the measured object, external temperature, etc., resulting in significant and irregular measurement and calculation errors) is a very difficult parameter to determine, which further seriously affects the accuracy of the equivalent model in predicting overvoltage.
In the domain of modeling, advanced methodologies such as distributed-parameter models and ladder network equivalents have been developed. A multi-segment π-type cable model was introduced in ref. [23] to accurately represent high-frequency responses, though it necessitates elaborate parameter extraction. The ladder network-equivalent circuit is widely used for its simulation accuracy. However, cable and motor winding models utilizing excessive branches and distributed representations can impose a high computational load, often rendering corresponding simulations unfeasible. Recent work, such as ref. [24], has incorporated bearing current paths into models, enhancing practical relevance. Nevertheless, these modeling strategies generally rely on detailed system parameters, which constrains their generality under the variable operating conditions typical of electric vehicle (EV) applications. In addition, the seminal review by ref. [25] systematically analyzes the fundamental challenge of maximizing power transfer and efficiency in coupled resonant systems, framing solutions around principles of impedance matching and frequency-domain characteristics. The ref. [26] focused on a magnetic coupler, a system-level design paradigm where achieving desired performance is accomplished by characterizing and optimizing the system’s global frequency response and electromagnetic behavior rather than by perfecting individual component models in isolation. Therefore, this paper shifts from extracting single cable and motor parameters that are prone to errors to directly using the measured global frequency response signal (anti-resonance) of the entire inverter cable motor system for predictive modeling. Recent advancements in Digital Twin (DT) technology for Permanent Magnet Synchronous Motors (PMSMs) underscore a significant paradigm shift towards intelligent monitoring systems that integrate data and physical principles. Studies such as those referenced in refs. [27,28] exemplify the convergence of physics-based modeling with data-driven analytics to facilitate real-time condition evaluation. Collectively, these works highlight a pivotal prerequisite for effective DTs: we require models that are not only efficient and precise but also embeddable, enabling real-time state predictions to inform the core analytics of the Digital Twin.
Despite progress in modeling techniques, existing methods still rely on precise parasitic parameters, such as per-unit-length capacitance and inductance, which are often difficult to obtain in practical electric vehicle (EV) designs. Although prior research efforts, including that in ref. [29], have employed experimental approaches to streamline parameter identification, load testing during the manufacturing stage carries the risk of inflicting damage on the motor. In summary, for motor systems driven by high-frequency, high-speed inverters, conventional time-domain methods often lack the accuracy needed for reliable overvoltage prediction, while oversimplified models fail to capture high-frequency dynamics. Furthermore, distributed ladder models, though more representative, impose prohibitive computational costs. Compounding these limitations, on-load testing during manufacturing can lead to irreparable damage. As a result, electric vehicle manufacturers currently lack a simple, accurate, and computationally efficient method to predict motor terminal overvoltage in the early design stage.
To address these shortcomings, this paper proposes a novel method that combines frequency scanning with a lumped ladder network fitted model. The anti-resonant frequency of the cable–motor system is identified through frequency-domain analysis, and the characteristic impedance obtained from this analysis serves as the direct input to a lumped ladder network model. While balancing computational efficiency with accuracy remains a challenge in such fitted models, this approach enables accurate prediction of motor terminal overvoltage. Moreover, the need for extensive parasitic parameter extraction is significantly reduced, thereby lowering the overall computational burden. This work builds upon established international research on wave reflection theory and incorporates recent regional advances in model simplification, offering a practical tool for early-stage design assessment in EV drive systems.

2. Lumped Ladder Network Model and Analysis

This paper proposes a simplified lumped ladder network model to represent the inverter–cable–motor system for overvoltage prediction. Unlike traditional distributed parameter models that require complex parameter extraction, the proposed model uses a reduced-order structure with lumped components, maintaining accuracy while significantly lowering computational complexity. The model comprises two main parts, the RL-Network and the CG-Network, as illustrated in Figure 3.
Figure 3. The simplified lumped ladder network model.
A three-stage lumped ladder network is employed to model the cable segment within the inverter–cable–motor system. Each stage of this network incorporates series RL components and parallel CG components, collectively representing the cable’s frequency-dependent behavior. This configuration effectively captures the high-frequency characteristics, particularly the anti-resonance phenomena, associated with PWM pulse propagation along the cable, while obviating the need for detailed distributed parameter extraction. The motor load is represented by a simplified ladder equivalent circuit, which accounts for key elements including an RL network representing the windings, interturn lumped capacitance, parasitic capacitance to ground, and the bearing impedance path.
Theoretically, perfect agreement between actual frequency-dependent parameters and simulation results requires an equivalent network with an infinite number of branches. As such an infinite-branch model is impractical for engineering applications, a simplified representation must be adopted. The analysis begins by considering the first two branches extracted from a multi-level ladder model, as depicted in Figure 4.
Figure 4. Equivalent circuit for frequency-dependent parameter representation with infinite branches.
By knowing two sets of cable parameters, i.e., resistance and inductance for two different anti-resonance frequencies, it is possible to evaluate the simplified equivalent circuit parameters (R1, L1, R2, L2) as follows.
The parameters for a simplified two-branch equivalent circuit (denoted R1, L1, R2, L2) can be derived from two sets of measured cable parameters, specifically, the resistance and inductance pairs at two distinct anti-resonance frequencies, ω1 and ω2. The inductance and resistance at these frequencies are defined as L_eq(ω1), R_eq(ω1), and L_eq(ω2), R_eq(ω2), respectively. The circuit parameters are calculated using the established Formulas (1)–(4).
L 2 = L e q ( ω 1 ) − Δ L ⋅ ( Δ R 2 Δ L 2 + ω 2 2 ) ω 2 2 − ω 1 2
R 2 = Δ R Δ L ( L e q ( ω 2 ) − L 2 ) + R e q ( ω 2 )
I 1 = R 2 2 ⋅ ( ω 2 2 − ω 1 2 ) Δ L ⋅ ( Δ R 2 Δ L 2 + ω 1 2 ) ( Δ R 2 Δ L 2 + ω 2 2 )
R 1 = R 2 − L 1 ⋅ Δ R Δ L
where
Δ L = L e q ( ω 1 ) − L e q ( ω 2 )
Δ R = R e q ( ω 2 ) − R e q ( ω 1 )
The Leq(ω1) and the Leq(ω2) are cable inductance at the anti-resonance frequency ω1 and ω2, respectively. The Req(ω1) and the Req(ω2) are cable inductance at the anti-resonance frequency ω1 and ω2, respectively.
For scenarios where cable measurement data provides ‘n’ pairs of resistance and inductance values, a more precise equivalent circuit with up to ‘n’ branches can be constructed. The parameter extraction follows a sequential, top-down procedure:
Step 1: Highest-Order Branch Calculation. From the ‘n’ available measurement pairs, select the two corresponding to the highest frequencies, ω(n−1) and ω(n). The parameters for the highest-order branch (Branch n), Rn and Ln, are computed using Equations (1) and (2).
Step 2: Sequential Circuit Order Reduction. The impedance of the remaining unevaluated part of the circuit (Branches 1 to n − 1) is then calculated. For each measurement frequency ωi (where i = 1 to n − 1), the equivalent resistance R′eq(ωi) and inductance L′eq(ωi) of this reduced circuit are determined using Equations (7) and (8), as illustrated in Figure 5. Here, Req(ωi) and Leq(ωi) are the original measured values.
L e q ( ω i ) ′ = R n 2 · ( L e q ( ω i ) − L n ) ( R n − R e q ( ω 1 ) ) 2 + ω i 2 ⋅ ( L e q ( ω i ) − L n ) 2
R e q ( ω i ) ′ = R n ⋅ [ R e q ( ω i ) ⋅ R n − R e q ( ω i ) 2 − ω i 2 · ( L e q ( ω i ) − L n ) 2 ] ( R n − R e q ( ω 1 ) ) 2 + ω i 2 ⋅ ( L e q ( ω i ) − L n ) 2
where Req(ωi), Leq(ωi) are the resistance/inductance pair related to the frequency ωi, as given by the supplied data.
Figure 5. Cable equivalent circuit with “n” branches.
Step 3: Iterative Parameter Determination. The process is repeated iteratively. Using the two highest-frequency results from Step 2 (i.e., for ω(n−2) and ω(n−1)), the parameters for the next branch (Branch n − 1) are calculated via equations analogous to (1) and (2). Steps 2 and 3 are reiterated for successively lower frequencies (ω(n−3), …, ω1) until the parameters for the first branch (R1, L1) are finally obtained using Equations (3) and (4). The CG-Network adopts the same calculation method.

3. Frequency-Domain Scanning Method and Data Extraction with Model Validation

3.1. Frequency Scanning Methodology

This section presents the frequency-domain scanning approach employed for parameter extraction and model validation. The proposed method utilizes impedance analysis to characterize the system’s frequency response without requiring detailed physical parameters. The scanning setup, as illustrated in Figure 6, connects an impedance analyzer between the inverter output terminals and motor input terminals, measuring both differential-mode and common-mode impedance characteristics across the frequency range of 20 Hz to 100 MHz.
Figure 6. The scanning setup of the cabler and motor system [17].
The scanning procedure involves applying a sinusoidal voltage sweep with constant amplitude while measuring the resulting current response. This allows for the extraction of impedance magnitude (|Z|) and phase angle (θ) at each frequency point. The frequency resolution is set to 100 Hz for detailed characterization around critical frequencies, with particular attention to anti-resonance points where impedance reaches local minima. The scanning configuration ensures comprehensive coverage of the frequency range relevant to PWM harmonic components in SiC-based drives.

3.2. Data Extraction and Anti-Resonance Identification

The extracted frequency response data undergoes systematic processing to identify key parameters for the lumped ladder network model. Figure 7 demonstrates a typical impedance magnitude curve obtained from the frequency scanning, showing distinct anti-resonance points at specific frequencies.
Figure 7. The CM and the DM impedance of the cabler and motor system [17].
The data extraction process involves the following steps. The first is anti-resonance frequency identification, which refers to using peak detection algorithms to locate frequencies where impedance magnitude reaches local minima, corresponding to system resonances. The next step, equivalent parameter derivation, involves calculating R, L, and C values for the ladder network based on the anti-resonance frequencies. For example, in a system with 2 m cable length, the scanning reveals a primary anti-resonance frequency of approximately 102 kHz (DM) and 9 MHz (DM), as shown in Figure 7.

4. Experimental Platform Introduction and Validation

The experimental platform was designed to comprehensively validate the proposed frequency scanning-based overvoltage prediction method for SiC inverter-fed motor drives. As illustrated in Figure 8, the test setup comprises three main subsystems: the SiC inverter system, the motor–cable assembly, and the measurement instrumentation system. The inverter system utilizes a three-phase two-level voltage source inverter based on silicon carbide MOSFETs (Cree C2M0040120D, Cree, Inc., Durham, NC, USA, 1200 V/60 A) to emulate the high switching characteristics typical of electric vehicle traction drives. The DC-link voltage is supplied by a programmable DC power source (MAGNA SD2000-15.0, Magna-Power Electronics, Inc., Flemington, NJ, USA) with adjustable voltage range from 50 V to 600 V, enabling systematic investigation of overvoltage behavior under different voltage stress levels. The inverter switching control is implemented through a digital signal processor (Texas Instruments TMS320F28335, Texas Instruments, Dallas, TX, USA) operating in conjunction with a field-programmable gate array (Xilinx XC3S400, Xilinx, Inc., San Jose, CA, USA), providing flexible PWM generation with switching frequencies adjustable from 10 kHz to 100 kHz. This frequency range covers both conventional IGBT-based drives and high-frequency SiC-based drives, allowing comprehensive evaluation of the proposed method across different operating regimes. The motor–cable assembly consists of a 7.5 kW three-phase induction motor (380 V, 50 Hz, 4-pole) connected to the inverter output through variable-length three-phase shielded power cables. The motor features standard insulation class F and isolated bearings to facilitate accurate measurement of bearing currents without interference from bearing short circuits. The cable employed is a cross-linked polyethylene (XLPE) insulated three-core shielded cable with a nominal cross-sectional area of 2.5 mm2 per conductor and characteristic impedance of approximately 100 Ω. Each test condition was repeated three times. The results reported in the figures are the averages.
Figure 8. The experimental setup.
The experimental results demonstrate the effectiveness of the proposed method in predicting motor terminal overvoltage. Figure 9 shows the comparison between predicted and measured overvoltage at the motor terminals with a switching frequency of 10 kHz and DC-link voltage of 600 V. The proposed model successfully replicates the fundamental overvoltage phenomenon. Most notably, it accurately captures the characteristic reflection-induced voltage doubling at the motor terminals. While the inverter output shows a square-wave pulse approximating the DC-link voltage (e.g., ~600 V), both the measured and predicted motor terminal voltages exhibit a pronounced first peak reaching approximately twice that amplitude (~1048 V at 0.2 µs), which is the primary threat to insulation.
Figure 9. The comparison between predicted and measured overvoltage at the motor terminal.
Experimental validation confirms the high accuracy of the proposed model in predicting transient overvoltage waveforms at the motor terminals. As demonstrated in Figure 9, for example, for a configuration with a 600 V DC-link and 10 kHz switching frequency, the predicted waveform shows excellent agreement with the measured one in all key aspects. The model accurately reproduces the characteristic voltage doubling effect, where the first peak at the motor terminals reaches approximately 1048 V, in stark contrast to the ~600 V inverter output pulse. Quantitative analysis reveals a deviation of less than 5% for this critical first peak (e.g., 1052 V predicted vs. 1048 V measured). Furthermore, the model faithfully captures the high-frequency ringing following the peak, including its oscillation frequency and damping decay. The precise temporal alignment of the predicted transient’s rise time and phase with the measured data underscores that the simplified lumped ladder network, parameterized via frequency scanning, correctly embodies the wave propagation and resonant dynamics of the physical cable–motor system.
To validate the applicability of the proposed method to other cable–motor systems, tests were conducted on a setup featuring a 0.7 m long cable and a 5 kW low-power motor. The same frequency scanning procedure was employed to extract the system’s anti-resonant frequency, and the updated fitted model was used for prediction. A comparative analysis between the predicted and measured motor terminal overvoltage is presented in Figure 10. As shown, the measured overvoltage peaks at approximately 867 V, while the model predicts a peak of about 920 V (error < 10%).
Figure 10. The comparison between predicted and measured overvoltage at the motor terminal (0.7 m long cable).
Figure 11 shows the magnitude of overvoltage against the rising time (tr) of the inverter output voltage pulse. The overvoltage decreases monotonically from approximately 1093 V to 900 V as the rising time increases from 30 ns to 80 ns. Crucially, the predicted values (calculated, dashed red line) demonstrate excellent agreement with the experimentally measured data (measured, indicated by the solid blue line) across the entire tested range. For instance, at tr = 30 ns, the model predicts around 1070 V against a measured value of around 1093 V. While the overall trend is accurately replicated, a consistent, marginal offset is observable, particularly in the shorter-rising-time regime (tr < 40 ns). Here, the model slightly underestimates the overvoltage. This deviation is anticipated and can be attributed to the model’s simplified lumped-parameter structure, which may not fully capture all extreme high-frequency parasitic effects that become dominant at ultra-short rise times.
Figure 11. The comparison between predicted and measured overvoltage with different rising time.
Table 1 shows the performance of different modeling approaches. While traditional distributed-parameter and detailed ladder network models can, in theory, offer high accuracy, their practical application is hindered by a heavy dependence on numerous physical parameters that are both difficult to measure accurately and sensitive to frequency variations, in addition to incurring high computational costs. The method proposed in this paper—a frequency sweep-based, lumped ladder network model—offers a fundamental simplification. It circumvents the complex extraction of physical parameters by directly utilizing the system’s global frequency response characteristic, namely its anti-resonant frequency. As the table demonstrates, this approach maintains high prediction accuracy (with errors below 10%) while substantially reducing both the parameter requirements and the computational burden. It also provides superior generality and ease of implementation. These advantages confirm the methodological innovation of our proposal in successfully balancing the traditionally conflicting demands of prediction precision, computational efficiency, and practical usability.
Table 1. Key performance indicators of the modeling methods.
Motivated by the superior accuracy of distributed parameter models in capturing high-frequency transmission line effects, this study investigated whether segmenting the lumped model—effectively creating a finer, multi-section ladder network—could improve predictive fidelity. The segmented models were tested under identical conditions. Figure 12 presents a comparative evaluation of overvoltage prediction accuracy when applying a segmentation strategy to the proposed lumped ladder network model. The graph plots overvoltage against time, comparing the measured waveform with predictions from two segmented versions of the model: one with a 1 m segment length per unit cell and another with a 2 m segment length. The results, however, demonstrate a significant and counterintuitive deviation. Contrary to the expected improvement, both segmented models show markedly poorer agreement with the measured data compared to the standard (non-segmented) lumped model results presented in earlier figures. Specifically, the segmented predictions exhibit substantial inaccuracies in capturing both the amplitude of the initial overvoltage peak near 30 µs and the damping characteristics of the subsequent oscillations. The waveform from the “2 m/Cell” model shows particularly pronounced errors in both magnitude and phase.
Figure 12. The impact of the lumped model’s segmentation on prediction accuracy.
This outcome indicates that the arbitrary segmentation of the empirically derived lumped model disrupts its calibrated impedance–frequency relationship. The original model’s parameters were optimized via frequency scanning to represent the aggregated behavior of the entire cable–motor system. Artificially dividing it into uniform physical segments (1 m or 2 m) without re-deriving the parameters for each segment from first principles or measurement data introduced unrealistic discontinuities and altered the system’s resonant response. Consequently, this approach degraded rather than enhanced prediction accuracy, underscoring that the validated accuracy of the proposed lumped model stems from its holistic, frequency-domain parameterization rather than from emulating the spatial discretization of distributed models.

5. Conclusions

This study presented and experimentally validated a simplified overvoltage prediction method for SiC-based motor drive systems, utilizing a frequency scanning approach in conjunction with a lumped ladder network model. The proposed technique directly estimates overvoltage amplitude by identifying system anti-resonance frequencies through impedance analysis, thereby eliminating the need for the complex parasitic parameter extraction required by traditional distributed or detailed ladder network models. The experimental results demonstrate the method’s effectiveness and practicality, with prediction errors consistently below 10% across a comprehensive test matrix encompassing various rising times. The method offers significant advantages, including a computational load reduction of over 50% compared to conventional approaches, strong adaptability to different cable types and motor specifications without re-parameterization, and a unique capacity for pre-deployment design-stage risk assessment. A noted limitation is the model’s decreased accuracy at various high frequencies, where simplified lumped-parameter representation becomes less precise. This is because under high-frequency excitation, the overvoltage of the motor will be further amplified by high-frequency resonance. Future work will focus on adapting the lumped model to the resonance effects in extremely high-frequency environments and exploring its integration into real-time monitoring systems to further enhance its applicability as a reliable and efficient design support tool for electric vehicle drive systems. Further, the segmentation effects of the lumped ladder network fitted model, including its physical mechanisms and potential re-identification strategies, will be a key focus of our subsequent research.

Author Contributions

Methodology and software, X.L.; formal analysis and writing—review and editing, Y.X.; software, C.L.; validation, J.D.; project administration and writing—editing, W.C. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the Sailing program of Yibin University under project 2023QH24. This work was supported by the opening project of the State Key Laboratory of Explosion Science and Safety Protection (Beijing Institute of Technology) under grant number KFJJ25-11M.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Li, S.; Lu, S.; Mi, C. Revolution of Electric Vehicle Charging Technologies Accelerated by Wide Bandgap Devices. Proc. IEEE 2021, 106, 985–1003. [Google Scholar] [CrossRef] [Scilit]
  2. Li, W.; Liu, S.; He, T.; Zhu, L. Iron Loss Analysis in Amorphous Alloy High-Speed Permanent Magnet Motors Utilizing a Preisach Hysteresis Based Method. IEEE Trans. Energy Convers. 2026, 1–12. [Google Scholar] [CrossRef] [Scilit]
  3. Zhu, L.; Ji, H.; Xu, T.; Gao, N.; Wang, K.; Huang, M.; Fan, R.; Jin, X.; Li, W.; Koh, C.-S.; et al. Three-Dimensional Analysis and Experimental Verification of a Novel Magnetic Lead Screw with Checkerboard Array Magnetic Pole. IEEE Trans. Transp. Electrif. 2025, 11, 8677–8688. [Google Scholar] [CrossRef] [Scilit]
  4. Zhu, L.; Zhu, L.; Wu, Q.; Xu, T.; Huang, M.; Gao, N.; Wang, K.; Wu, W.; Li, W.; Koh, C.-S.; et al. Design, Optimization, and Experimental Study of a Novel Direct-Driven Linear-Rotary Wave Generator. IEEE Trans. Energy Convers. 2025, 40, 1712–1725. [Google Scholar] [CrossRef] [Scilit]
  5. Fard, M.T.; He, J.; Wei, L.; Ilka, R.; Mirafzal, B.; Fateh, F. Mitigation of Motor Reflected Overvoltage Fed by SiC Drives—A New Solution Based on Smart Coils. IEEE Trans. Power Electron. 2025, 40, 4335–4344. [Google Scholar] [CrossRef] [Scilit]
  6. Divljakovic, V.; Kline, J.; Barta, D.; Floryan, D. Aging of Magnet Wire in the Presence of Variable Frequency, High Rise Time and High Voltage Pulses. In Proceedings of the IEEE Conference Electrical Insulation and Dielectric Phenomena—(CEIDP’94), Arlington, TX, USA, 23–26 October 1994. [Google Scholar]
  7. Kim, S.-O.; Lee, K.-B. PWM Technique to Minimize Output Voltage Distortion for Mitigating Motor Overvoltage Caused by the Reflected Wave Phenomenon. IEEE Trans. Power Electron. 2026, 41, 3467–3480. [Google Scholar] [CrossRef] [Scilit]
  8. Paula, H.D.; de Andrade, D.A.; Chaves, M.L.R.; Domingos, J.L.; de Freitas, M.A.A. Methodology for Cable Modeling and Simulation for High-Frequency Phenomena Studies in PWM Motor Drives. IEEE Trans. Power Electron. 2008, 23, 744–752. [Google Scholar] [CrossRef] [Scilit]
  9. Wang, L.W.; Ho, C.N.M.; Canales, F.; Jatskevich, J. High-Frequency Modeling of the Long-Cable-Fed Induction Motor Drive System Using TLM Approach for Predicting Overvoltage Transients. IEEE Trans. Power Electron. 2010, 25, 2653–2664. [Google Scholar] [CrossRef] [Scilit]
  10. Fan, X.; Li, W.; Ke, Q.; Xue, J.; Zhu, L. Hysteresis-Based Mechanism Analysis of Iron Loss Increment Caused by PWM Harmonics in Permanent Magnet Synchronous Motor. IEEE Trans. Ind. Appl. 2025, 61, 7175–7187. [Google Scholar] [CrossRef] [Scilit]
  11. Bentley, J.M.; Link, P.J. Evaluation of motor power cables for PWM AC drives. IEEE Trans. Ind. Appl. 1997, 33, 342–358. [Google Scholar] [CrossRef] [Scilit]
  12. Kaufhold, M.; Aninger, H.; Berth, M.; Speck, J.; Eberhardt, M. Electrical Stress and Failure Mechanism of The Winding Insulation in PWM-Inverter-Fed Low-Voltage Induction Motors. IEEE Trans. Ind. Electron. 2000, 47, 396–402. [Google Scholar] [CrossRef] [Scilit]
  13. Scott, M.J.; Brockman, J.; Hu, B.; Fu, L.; Xu, L.; Wang, J.; Zamora, R.D. Reflected Wave Phenomenon in Motor Drive Systems Using Wide Bandgap Devices. In Proceedings of the 2014 IEEE Workshop on Wide Bandgap Power Devices and Applications, Knoxville, TN, USA, 13–15 October 2014. [Google Scholar]
  14. Narayanasamy, B.; Sathyanarayanan, A.S.; Luo, F.; Chen, C. Reflected Wave Phenomenon in SiC Motor Drives: Consequences, Boundaries, and Mitigation. IEEE Trans. Power Electron. 2020, 35, 10629–10642. [Google Scholar] [CrossRef] [Scilit]
  15. Narayanasamy, B.; Sathyanarayanan, A.S.; Deshpande, A.; Luo, F. Analysis and Mitigation of Reflected Wave Voltages and Currents in WBG Devices Based Motor Drives. In Proceedings of the 2016 IEEE 4th Workshop on Wide Bandgap Power Devices and Applications (WiPDA), Fayetteville, AR, USA, 7–9 November 2016. [Google Scholar]
  16. Zhou, W.; Diab, M.S.; Yuan, X. Impact of Parasitics and Load Current on the Switching Transient Time and Motor Terminal Overvoltage in SiC-Based Drives. In Proceedings of the 2020 IEEE Energy Conversion Congress and Exposition (ECCE), Detroit, Michigan, 11–15 October 2020. [Google Scholar]
  17. Xu, Y.; Yuan, X.; Ye, F.; Wang, Z.; Zhang, Y.; Diab, M.; Zhou, W. Impact of High Switching Speed and High Switching Frequency of Wide-Bandgap Motor Drives on Electric Machines. IEEE Access 2021, 9, 82866–82880. [Google Scholar] [CrossRef] [Scilit]
  18. He, J.; Sizov, G.Y.; Zhang, P.; Demerdash, N.A. A Review of Mitigation Methods for Overvoltage in Long-Cable-Fed PWM AC Drives. In Proceedings of the 2011 IEEE Energy Conversion Congress and Exposition, Phoenix, AZ, USA, 17–22 September 2011. [Google Scholar]
  19. Desmet, J.; Devos, B.; de Goedelaan, G.K.; Belmans, R.; Hameyer, K. A Practical Approach to the Influence of Long Lead Cables on Inverter Supplied Induction Motors. In Proceedings of the International conference on Electrical Machine (ICEM—1998), Istanbul, Turkey, 2–4 September 1998. [Google Scholar]
  20. Wang, L.; Ho, C.N.; Canales, F.; Jatskevich, J. High-Frequency Cable and Motor Modeling of Long-Cable-Fed Induction Motor Drive Systems. In Proceedings of the 2010 IEEE Energy Conversion Congress and Exposition, Atlanta, GA, USA, 12–16 September 2010. [Google Scholar]
  21. Jafari, A.; Nikoo, M.S.; Perera, N.; Yildirim, H.K.; Karakaya, F.; Soleimanzadeh, R.; Matioli, E. Comparison of Wide-band-gap Technologies for Soft-Switching Losses at High Frequencies. IEEE Trans. Power Electron. 2021, 36, 2444–2445. [Google Scholar] [CrossRef] [Scilit]
  22. Xu, Y.; Peng, J.; Du, Z.; Wen, L.; Li, Q.; Zhou, G. Impact of High-Frequency Distributed Parametric Cable Model and Motor Overvoltage with SiC Inverter. In Proceedings of the 2025 2nd International Conference on the Frontiers of Electronic, Electrical and Information Engineering (ICFEEIE), Yibin, China, 22–24 August 2025; pp. 1–8. [Google Scholar]
  23. Abdullah, H.; Uwe, S. A Full Frequency-Dependent Cable Model for the Calculation of Fast Transients. Energies 2017, 10, 1158. [Google Scholar]
  24. Yang, M.; Cheng, Y.; Du, B.; Li, Y.; Wang, S.; Cui, S. Research on Analysis and Suppression Methods of the Bearing Current for Electric Vehicle Motor Driven by SiC Inverter. Energies 2024, 17, 1109. [Google Scholar] [CrossRef] [Scilit]
  25. Wang, H.; Wu, Y.; Madawala, U.K.; Li, X.; Dai, X.; Sun, Y.; Hu, J. Integrated Coupler Design for UAV Free-Positioning Wireless Power Transfer with Inherent Cross- Coupling Utilization and Enlarged Charging Coverage. IEEE Trans. Power Electron. 2025, 40, 14324–14330. [Google Scholar] [CrossRef] [Scilit]
  26. Hui, S.Y.R.; Zhong, W.; Lee, C.K. A Critical Review of Recent Progress in Mid-Range Wireless Power Transfer. IEEE Trans. Power Electron. 2014, 29, 4500–4511. [Google Scholar] [CrossRef] [Scilit]
  27. Lukman, G.F.; Lee, C. Towards Digital Twin Modeling and Applications for Permanent Magnet Synchronous Motors. Energies 2025, 18, 956. [Google Scholar] [CrossRef] [Scilit]
  28. Kumar, N.B.; Babu, A.R.V.; Kumar, M.B.A.; Kumar, T.S.; Babu, V.G. Hybrid digital twin-based fault diagnosis framework for PMSMs in electric vehicle applications. Frankl. Open 2025, 12, 100328. [Google Scholar] [CrossRef] [Scilit]
  29. Lackie, T.; Jiang, Y.; Shillaber, L.; Long, T. Motor overvoltage mitigation by active cancellation of reflections using parallel SiC devices with a coupled inductor. IEEE Trans. Power Electron. 2023, 38, 11368–11384. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics